You are on page 1of 217
e@ SEMESTER -W a (For Diploma & Polytechnic Students | CIVIL ENGINEERING GROUP Estimating & Costing Prof. Bharat Bhushan Jogindra kohli ee EOL} i in | NEW SYLLABUS alvanvoglsascot! ESTIMATING AND COSTING SEMESTER-V| i Strictly as per new syllabus i | w.e.f. academic year 2016-17 | L Ritu publication SYLLABU: 1. Overview of Estimating and Costing 1.1 Meaning of the terms estimating, costing. Purpose of estimating and i 7 Costin 1.2 with 35% composeai or 5% pudlo, by weight or other stand, water proofing materials as specified. Superstructure : Superstructure shall be of first class brickwork with lime mortar y 1:6 cement mortar. . Roofing : Roof shall be RCC slab with an insulation layer and lime concrete terrain above, supported over R.S. Joists or R.C.C. beams as required. Height of the rooms shall nq be less than 4 m (12'. Flooring : Drawing room and dining room floors shall be of mosaic. Bathroom and WC. floors and dado shall be of mosaic. Floors of bedrooms shall be coloured and polished of 2.5 cm cement concrete over 7.5 em lime concrete. Floors of others shall be of 2.5 cm cement concrete over 7.5 cm lime concrete, polished. Finishing : Inside and outside shall be of 13 mm cement plastered 1:6. Drawing, dining and bedrooms, inside shall be distempered and others, inside white washed 3 coats. Outside shall be colour washed two coats over one coat of white wash. Doors and Windows : Frames shall be of well seasoned teak wood. Shutters shall be teak wood 4.5 em thick panelled, glazed or partly panelled and partly glazed as required with additional wire gauge shutters. All fittings shall be of brass. Doors and windows shall be vamished or painted with high class enamel paint, Windows shall be provided with iron gratings. Miscellaneous : Rainwater pipes of cast iron or of asbestos cement shall be provided, finished and painted. Building shall be provided with first class sanitary and water fittings and electrical installations, 1 m to 1.5 m wide apron shall be provided all round the building, General Specifications of a Second Class Building : Foundation and Plinth : Foundation and plinth shall be of first class brickwork wih lime mortar over lime concrete. — Estimating and Costing [2-9] Detailed Estimate 1 Damp Proof Course : DPC shall be of 2 cm thick cement mortar 1:2 with =” composeal of 5% pudlo by weight of cement or other standard water proofing materials. Superstructure : The superstructure shall be of second class brickwork in mud mortar except usual trimming as joints, sills etc. which shall be of second class brickwork in lime mortar. Roofing : Roof shall be flat terraced roof supported over wooden battens and beams of jack arch roof, or R.B. roof. Verandah roof may be of A.C. sheet or Allahabad tiles. Flooring : Floors shall be of 2.5 cm cement concrete over 3.5 cm lime concrete. Verandah floor shall be of brick flat or flag stone over lime concrete, finished cement painted. ig : Inside shall be of lime or cement mortar plastered and outside cement mortar plaster with painting. Ceiling shall be plastered in C:M (1:3). Inside shall be white washed in 3 coat. Outside should be colour washed in 2 coats over the coat of white wash. Doors and Windows : Frames shall be of well seasoned teakwood and shutters of sal, deodar or shisham wood 4 cm thick, panelled or glazed as required: They should be fitted with iron fittings and painted in 2 coats. Miscellaneous : Rain water pipes shall be of cast iron. Electrification, sanitary and water fitting can be provided as per the requirements. A complete description can be written by using detailed specifications. Detailed Specifications of Various Items of Work : (A) P.C.C. 1:4:8 for Foundation Concrete : 1. General : Ordinary portland cement shall be used. The cement shall conform to LS. 269 - 1958. Cement remaining in store for more than 60 days from the date of receipt from the factory shall be subjected to tests and used only if found satisfactory. 2. Coarse aggregate shall be of hard broken stone of granite or similar stone, free from dust and other organic materials. The stone ballast shall be of 40 mm size and well graded, so that the voids do not exceed 42 per cent. 3. Fine aggregate shall be of coarse sand, consisting of hard, sharp and angular grains and shall pass through screen of 4.75 mm square mesh. Sand shall be of standard specifications, clean and free from dust, dirt and organic matters. 4, Water shall be clean, free from alkaline and acid matters and only potable water shall be used.

You might also like