Professional Documents
Culture Documents
CONVERSION TABLE
FPS AND METRIC SYSTEM
(TABLE – 1 TO 3)
TABLE – 1
TABLE – 2
CONVERSION FACTOR CONVERSION FACTOR
British Remarks
Metric SI SI Metric British (FPS)
(FPS)
Length 1 in 25.4 mm 25.4 mm 1 mm 1 mm 0.0937 in 1 in = 2.54 cm
1 ft. 0.3048 m 0.3048 m 1 cm 1 cm 0.3937 in
1 yd 0.9144 m 0.9144 m 1m 1m 3.281 ft.
1 mile 1.609 km 1.609 km 1 km 1 km 0.6214 mi
1 mile 1.852 km 1.852 km 1 km 1 km 0.5399 mile
(nautical) (nautical)
Area 1 in2 6.452 cm2 6.452 cm2 1 cm2 1 cm 0.155 in2 1 in2 = 645.2 mm2
1 ft 2 0.0929 m2 0.0929 m2 1 m2 1 m2 10.764 ft2 1 acre = 43561ft2 = 4047 m2
1 yd2 0.8361 m2 0.8361 m2 1 m2 1 m2 1.196 yd2 1 km2= 247.105 acres
1 mi2 2.59 km2 2.59 km2 1 km2 1 km 0.3861 mi2 1 hectre = 10000 m2
acre 0.4047 ha 0.4047 ha 1 ha 1 ha 2.471 acre
Volume 1 in3 16.387 cm3 16.387 cm3 1 cm3 1 cm3 0.061 in3 1 ft3 = 6.23901 gal = 28.316
1 ft3 0.02832 m3 0.02832 m3 1 m3 1 m3 35.315 ft3 liters
1 yd3 0.7648 m3 0.7648 m3 1 m3 1 m3 1.308 yd3 1 bushel = 36.37 liters
1 gal (UK) 4.546 liters 4.546 liters 1 liter 1 liter 0.22 gal (UK)
1 gal (US) 3.7854 liters 3.7854 liters 1 liter 1 liter 0.264 gal (US)
Moment of 1 in4 41.623 cm4 41.623 cm4 1 cm4 1 cm4 0.024 in4
Inertia 1 ft4 0.008631 m4 0.008631 m4 1 m4 1 m4 115.86 ft4
Miscellaneous Units:
TABLE – 3
CONVERSION FACTOR CONVERSION FACTOR
Remarks
British
Metric SI SI Metric British (FPS)
(FPS)
Mass 1 gr. 0.0648 gm 0.0648 gm 1 gm 1 gm 15.432 gm 1 lb = 0.486 seer
1 oz 28.349 gm 28.349 gm 1 gm 1 gm 0.0353 oz 1 kg = 1.072 seer
(avoir) 0.4536 kg 0.4536 kg 1 kg 1 kg 2.205 lbs = 85.74 tolas
1 lb
(avoir)
Conc. 1 lb 0.4536 kg 4.4482 N 1N 0.102 kg 0.2248 lb 1 kg = 2.2046 lb
load/force, 1 kip 453.6 kg 4.4482 kN 1 kN 101.96 kg 224.81 lb = 9.807 N
mass, weight 1 ton 1.016 tonne 9.964 kN 1 kN 101.96 kg 2.007 cwt 1 tonne = 10 quintal
(1016 kg) = 1000 kg
1 cwt 50.80 kg 0.4982 kN = 26.7923 mound
1 kg = 0.01968 cwt
1 ton = 2200 lb
=907.2 kg.
Linear loads 1 lb/in 0.01786 kg/mm 0.17512 1 N/mm 0.102 kg/mm 5.71 lb/in 1 kg/m = 9.80 N/m
(load per unit 1 lb/ft. 1.488 kg/m N/mm 1 kN/m 101.96 kg/m 68.52lb/ft. = 0.672 lb/ft.
length) 1 kip/ft. 1488.19 kg/m 0.0146 kN/m 1 kN/m 0.102 tonne/m 0.031 ton/ft
1 ton/ft 3.333 tonne/m 14.5939 kN/m
32.69 kN/m
Surface 1 lb/in2 0.0703 kg/cm2 6.895 kN/m2 1 mN/m2 10.15 kg/m2 145.038 lb/in2 1 kg /c m2 =
loads 1 lb/ft. 2 4.883 kg/m2 47.8803 1 kN/m2 101.92 kg/m2 20.885 lb/ft2 2048.312lb/ft2
(load per unit 1 kip/ft2 4883 kg/m2 kN/m2 1 kN/m2 0.102 tonne/ 0.00933 1 kg/cm2 = 1 atom
area) 1 ton/ft2 10.937 tonne /m2 47.8803 m2 ton/ft2 1 kg/m2 = 0.205 lb/ft2
kN/m2
107.14 kN/m2
Density 1 lb/in3 0.0000277 0.00027N/m 1 N/mm3 0.1021 kg/mm3 3703.70 lb/in3 1 kg/m3 = 0.0624 Ib/ft3
(unit weight) 1 lb/ft3 kg/mm3 m3 1 kN/m3 101.92 kg/m3 6.361 lb/ft3
1 ton/ft3 16.02 kg/m3 0.1572 kN/m3 1 kN/m3 0.102 0.0028 ton/ft 3
35.90 tonne/m3 352.08 kN/m3 tonne/m3
Stress, 1 lb/in2 0.703 kg/cm2 6.895 kPa 1 mPa 10.15 kg/cm2 145.038 lb/in2 MPa = MN/m2 = N/mm2 =
modulus of 1 kip/in2 70.3078 kg/cm2 6.895 mPa 1 kPa 101.92 kg/m2 20.885 lb/ft2 1000 kN/m2
elasticity, 1 lb/ft2 4.883 kg/m2 47.8803 Pa 1 Pa = 1N/m2
pressure 1 kN = 224.809 lbs
1 kg/cm2 = 14.223 lb/in2
1 ft. of water = 2.989 kPa
Moment/ 1 lb-in 11.5214 kg-mm 112.98 N-mm 1 N-mm 0.102 kg-mm 0.0088lb-in
Torque 1 lb-ft 0.1383 kg-m 1.3558 N-m 1 N-m 0.102 kg-m 0.738 lb-ft
1 kip-ft 138.3 kg-m 1.3558 kN-m 1 kN-m 0.102 tonne-m 0.3293 ton-ft
1 ton-ft 0.31 tonne-m 3.037 kN-m
Velocity/ 1 ft/sec 0.3048 m/sec 0.3048 m/sec 1 m/sec 1 m/sec 3.281 ft/sec
Speed 1 1.609 km/sec 1.609 km/sec 1 km/sec 1 km/sec 2237.42 mi/hr
mile/sec 0.4470 m/sec 0.4470 m/sec
1 mile/hr
Acceleration 1 ft/sec2 0.3048 m/sec2 0.3048 1 m/sec2 1 m/sec2 3.281 ft/sec2
m/sec2
TABLE – 4
UNIT WEIGHT OF ENGINEERING MATERIALS
Unit Weight of Different Materials Unit Weight of M.S. Flat Bars**
Unit weight Size Weight
Materials
lb/cft kg/cum inch mm* lb/rft kg/meter
Asphalt 66 1057
¾ x 1/8 20 x 3 0.32 0.471
Aluminium 165 2643
¾ x 3/16 20 x 5 0.48 0.785
Bamboo 25 400
¾x¼ 20 x 6 0.64 0.942
Bitumen 65 1040
1 x 1/8 25 x 3 0.43 0.589
Brass 534 8552
1 x 3/16 25 x 5 0.64 0.981
Bricks 69 1110
1x¼ 25 x 6 0.85 1.178
Brick ballast 60-70 960-1120
1 ¼ x 1/8 30 x 3 0.53 0.707
Brick chips 80-110 1280-1760
1 ¼ x 3/16 30 x 5 0.80 1.178
Brick work 120 1922
1¼ x¼ 30 x 6 1.06 1.413
Cast iron 450 7207
1 ½ x 1/8 40 x 3 0.64 0.942
Cement 90 1440
1 ½ x 3/16 40 x 5 0.96 1.570
Cement concrete 140 2240
1½ x¼ 40 x 6 1.28 1.884
Clay ( dry to wet) 115-130 1840-2080
2 x 3/3/16 50 x 5 1.28 1.9625
Coal (loose) 50 800
2x¼ 50 x 6 1.70 2.335
Copper 556 8905 UNIT WEIGHT OF M.S. SOLID SQUARE BARS
Earth (compacted & damp) 100 1600 Size Weight
Earth (dry & loose) 90 1440 inch mm* lb/rft kg/meter
Garjan timber 45-50 720-800
½x½ 12 x 12 0.851 1.130
Gravel 90 1440
¾x¾ 20 x 20 1.914 3.140
Lead 710 11371
1x1 25 x 25 3.403 4.906
Lime concrete 120 1920 UNIT WEIGHT OF M.S. Z-SECTION
Lime (slaked to fresh) 40-60 640-960 Size Weight
Lime stone 150 2400 inch mm* lb/rft kg/meter
Macadam (tar) 140 2242
¾ x ¾ x ¾ x 1/8 20 x 20 x 20 x 3 0.851 1.272
Marble 169 2707
¾ x ¾ x ¾ x 3/16 20 x 20 x 5 1.196 1.963
Mild steel 490 7850
1 x 1 x 1/8 25 x 25 x 3 1.170 1.625
Pebbles 90 1440
1 x 1 x 3/16 25 x 25 x 5 1.675 2.551
Plain concrete 144 2300 UNIT WEIGHT OF M.S. ANGLE
Reinforced cement concrete 150 2400 Size Weight
Sal wood 60-65 960-1040 inch mm* lb/rft kg/meter
Sand (dry to wet) 100-120 1600-1920
¾ x ¾ x 1/8 20 x 20 x 3 0.585 0.871
Shingles 90 1440
¾ x ¾ x 3/16 20 x 20 x 5 0.837 1.374
Silver 656 10506
¾x¾x¼ 20 x 20 x 6 1.063 1.601
Stone ballast 100 1600
1 x 1 x 1/8 25 x 25 x 3 0.798 1.107
Sundari wood 55-65 880-1040
1 x 1 x 3/16 25 x 25 x 5 1.156 1.766
Surki 80 1280
1x1x¼ 25 x 25 x 6 1.489 2.072
Surki mortar 85-120 1360-1920
1 ½ x 1 ½ x 1/8 40 x 40 x 3 1.223 1.813
Tar 90 1440
1 ½ x 1 ½ x 3/16 40 x 40 x 5 1.794 2.944
Teak wood 45-55 720-880
1½ x1½x¼ 40 x 40 x 6 2.339 3.485
Water at 40 C 62.45 1000
2 x 2 x 3/16 50 x 50 x 5 2.432 3.729
Wrought iron 480 7688
2x2x¼ 20 x 20 x 6 3.190 4.427
2½ x2½x¼ 65 x 65 x 6 4.041 5.840
3x3x¼ 75 x 75 x 6 4.891 6.782
3 x 3 x 5/16 75 x 75 x 8 6.048 8.918
** Unit weight with respect to FPS measurements of materials
* Measurements in soft conversion
PWD SoR 2014 for Civil Works 5
TABLE – 5
TABLE – 6
TABLE – 7
1
CROSS-SECTIONAL AREA AND MASS OF ROUND BAR
Nominal Size Bar No. Cross-sectional Perimeter in mm Mass per running Length per 100 kg in
(dia in mm) area in mm2 meter in kg meter
TABLE – 8
100 maunds of slaked lime or sand or Surki = 225 cft. (2.25 cft. = 1 maund)
100 cft. of khoa or brick chips required 850 Nos. bricks of size 9.5" x 4.5" x 2.75"
Standard Bricks (9.5" x 4.5" x 2.75")1000 Nos. = approx. 72 cft. = 2.039 cum = 3172 to 4000 kg.
1 bundle =
Size of C.I. sheet No of C.I. sheet Size of C.I. sheet No of C.I. sheet
1 gallon of plastic emulsion paint / synthetic enamel paint covers 300 sft. of new surface (approx.)
100 cft masonry brick work requires 1100 nos standard bricks (size 9.5" x 4.5" x 2.75") with 0.25” thickness
of mortar.
Brick Soling:
Single brick flat soling requires : 300 Nos. bricks per % sft. (Brick size 9.5" x 4.5" x 2.75")
Double brick flat soling requires : 600 Nos. bricks per % sft. (Brick size 9.5" x 4.5" x 2.75")
Herringbone bond (HBB) brick soling requires : 500 Nos. bricks pre % sft. (Brick size 9.5" x 4.5" x 2.75")
Brick on end edging requires : 250 Nos. bricks per % rft. (Brick size 9.5" x 4.5" x 2.75")
PWD SoR 2014 for Civil Works 9
RATES OF
MAN, MATERIAL AND
MARK-UPS
PWD SoR 2014 for Civil Works 10
39 Carriage of earth by any means for site development in Narayanganj / Chittagong / Tk. 5.22 cft
Sylhet city
Carriage of earth by any means for site development in Rajshahi / Barishal / Khulna
40 city Tk. 4.43 cft
Carriage of earth by any means for site development in all districts except Dhaka,
41 Ctg, and N'ganj. Tk. 3.65 cft
42 5-ton capacity truck-fare in Dhaka city in/c loading, unloading Tk. 1,300.00 Per trip
43 Concrete mixer machine Tk. 1,000.00 Per day
44 Concrete vibrator Tk. 500.00 Per day
45 Hire charge of water pump for concreting or similar purposes Tk. 432.00 Per day
46 Hire charge of diesel operated 1/4 cusec water pump Tk. 588.00 Per day
47 Hire charge of electricity operated 1 cusec water pump Tk. 760.00 Per day
48 Hire charge of 1 cusec diesel operated water pump Tk. 1,030.95 Per day
49 Fuel, lubricant for mixer machine, vibrator and pump etc. Tk. 1,051.00 Per day
50 Mosaic cutting machine Tk. 300.00 Per day
51 Marble cutting and shaping in/c cutting disc. Tk. 300.00 Per day
52 Marble polishing machine in/c polishing stone Tk. 400.00 Per day
53 Hire charge of marble cutting disk Tk. 775.14 Per day
54 Hire charge of electric grinding machine Tk. 206.00 Per day
55 Hire charge of cast in situ pile boring complete rig set in/c operational expenses Tk. 8,820.00 Per day
56 Hire charge of pre-cast pile driving complete rig set in/c -do-do- etc. Tk. 10,550.00 Per day
57 Hire charge of pre-cast micro pile driving complete rig set in/c -do-do- etc. Tk. 5,500.00 Per day
58 Hire charge of load testing devices in/c hydraulic fluid: up to 125 ton capacity Tk. 10,642.00 Per test
59 -do -do-: up to 275 ton capacity Tk. 12,519.00 Per test
60 Hire charge of diesel hammer mounted completed rig set. Tk. 23,707.00 Per day
61 Lifting and movement of crane for diesel mounted hammer up to site Tk. 50,000.00 Per set
62 Truck fare for carrying diesel hammer mounted rig Tk. 12,000.00 Per trip
PWD SoR 2014 for Civil Works 12
112 Ordinary Portland Cement, BDS-EN - 197-1- CEM1, 52.5N (52.5MPa)/ ASTM C- Tk. 470.00 Per bag
150 Type-I, 50 kg bag
113 Portland Composite Cement / CEM-II/A – M, 42.5N (42.5MPa) (6-20% constituents Tk. 440.00 Per bag
other than clinker): 50 kg bag
114 White Cement Tk. 25.00 Per kg
C7 STONE / BOULDER / MOSAIC CHIPS, BITUMEN / ADMIXTURE / MEMBRANE
115 Uncrushed boulder Tk. 12,500.00 Per % cft.
116 19 mm (3/4") downgraded crushed stone chips Tk. 14,500.00 Per % cft.
117 12 mm (1/2") downgraded stone chips Tk. 13,500.00 Per % cft.
118 Stone shingles Tk. 8,100.00 Per % cft.
119 Pea-gravel Tk. 5,500.00 Per % cft.
120 Slaked lime Tk. 19.00 Per kg
121 Surki from 1st class brick Tk. 58.00 Per cft.
122 Pakistan origin (onix) mosaic chips Tk. 19.00 Per kg
123 Indian origin (deradun) mosaic chips Tk. 17.00 Per kg
124 Pumice stone for finishing mosaic work Tk. 60.00 each
125 Minar stone for finishing mosaic work Tk. 400.00 each
126 Color pigment Tk. 55.00 Per lbs
127 20 mm x 50 mm glass strip Tk. 8.00 Per rft.
128 80/20 Bitumen for road work Tk. 65,333.33 Per M. ton
PWD SoR 2014 for Civil Works 14
181 16 mm thick marble stone, Black/white (Indian) Tk. 350.00 Per sft.
182 12 mm thick marble stone, Black/white (Indian) Tk. 315.00 Per sft.
183 18 mm thick colored/ grey marble stone (Indian) Tk. 410.00 Per sft.
184 16 mm thick colored/ grey marble stone (Indian) Tk. 360.00 Per sft.
185 12 mm thick colored/ grey marble stone (Indian) Tk. 345.00 Per sft.
186 18 mm thick colored/ grey marble stone (Italian) Tk. 550.00 Per sft.
187 wall tiles less than , equal or equivalent to 250mmx330mm in sizes Tk. 46.00 Per sft.
188 wall tiles more than 250 x 330 mm & less than 310 x510 mm in sizes or equivalent Tk. 54.00 Per sft.
189 wall tiles more than 310 X 510 mm in sizes or equivalent Tk. 75.00 Per sft.
190 GP (Gress Porcellanato) - Glazed Homogeneous 300 x 300 mm floor tiles Tk. 64.00 Per sft.
191 GP (Glazed Homogeneous) 400 x 400 mm floor tiles Tk. 74.00 Per sft.
192 GP (Mirror polished) 300 x 300 mm floor tiles Tk. 78.00 Per sft.
193 GP (Mirror polished) 400 x 400 mm floor tiles Tk. 88.00 Per sft.
PWD SoR 2014 for Civil Works 16
197 Unglazed Homogeneous Floor Tiles 400 x 400 mm Tk. 75.00 Per sft.
212 I-section joist to support inclined prop Tk. 482.00 Per rft.
213 4" x 2" M.S. box channel with 1/8" thick M.S. sheet Tk. 450.00 Per rft.
214 Steel prop with adjustable mechanism in/c top and bottom plate Tk. 1,680.00 Per set
215 Turn-buckle in/c tie rod Tk. 487.30 Per set
217 Weather coat / Acrylic based exterior emulsion Tk. 318.40 Per liter
218 Weather coat sealer ( Exterior) Tk. 209.60 Per liter
220 Ready-mix putty ( Exterior-interior) water based Tk. 76.00 Per liter
221 Sealer for ready-mix putty ( Exterior-interior) Tk. 228.00 Per liter
222 Synthetic Enamel paint ( alkyd based) Tk. 310.00 Per liter
228 Acrylic Plastic Emulsion Paint sealer Tk. 205.00 Per liter
235 Wood varnishing: Yacht ( alkyd based) Tk. 250.00 Per liter
236 Wood varnishing: Egg-shell ( alkyd based) Tk. 250.00 Per liter
237 Wood varnishing: Matt ( alkyd based) Tk. 250.00 Per liter
238 Thinner for alkyd based wood varnishing Tk. 104.00 Per liter
C14 French-Polishing
Rate
I. Aluminium Channel / Sections: Rate per rft. Unit
Bronze Silver S.S Color
252 101.60 mm, 44.45 mm wall frame of 1.2 mm thick Tk. 117.60 Tk. 115.50 Tk. 119.70 per rft.
254 16.54 mm, 15.49 mm Door glass bit of 0.99 mm thick Tk. 15.75 Tk. 14.70 Tk. 16.80 per rft.
255 101.54 mm, 42.93 mm closure system of 1.8 mm thick Tk. 123.90 Tk. 120.75 Tk. 126.00 per rft.
256 101.60 mm closure cover of 1.2 mm thick Tk. 47.25 Tk. 46.20 Tk. 48.30 per rft.
257 101.60 mm, 12.70 mm floor bottom of 4 mm thick Tk. 133.35 Tk. 129.15 Tk. 135.45 per rft.
258 82.60 mm, 43.99 mm door shutter bottom of 1.8 mm thick Tk. 158.55 Tk. 154.35 Tk. 161.70 per rft.
259 51 mm, 43.99 mm door shutter top of 1.8 mm thick Tk. 130.20 Tk. 126.00 Tk. 132.30 per rft.
261 101.60 mm, 44.45 mm top & side 1.8 mm thick Tk. 151.20 Tk. 147.00 Tk. 154.35 per rft.
262 101.35 mm, 44.45 mm bottom of 1.2 mm thick Tk. 112.35 Tk. 109.20 Tk. 114.45 per rft.
263 44.32 mm, 19.61 mm fixed bottom cover of 1.2 mm thick Tk. 42.00 Tk. 40.95 Tk. 43.05 per rft.
264 83.21mm, 16.00 mm fixed grouve cover of 1.2 mm thick Tk. 65.10 Tk. 64.05 Tk. 66.15 per rft.
265 39.09mm, 14.81mm fixed glass protector of 1.0 mm thick Tk. 25.20 Tk. 24.15 Tk. 26.25 per rft.
267 75.50 mm, 17.79 mm outer low bottom 0f 1.2 mm thick Tk. 61.95 Tk. 58.80 Tk. 63.00 per rft.
268 75.5 mm, 26.8 mm outer top of 1.2 mm thick Tk. 86.10 Tk. 82.95 Tk. 88.20 per rft.
269 33 mm, 26.80 mm, 22 mm shutter top of 1.2 mm thick Tk. 57.75 Tk. 55.65 Tk. 58.80 per rft.
270 60 mm, 24 mm shutter bottom of 1.2 mm thick Tk. 81.90 Tk. 79.80 Tk. 84.00 per rft.
271 75.50 mm, 19.90 mm outer side of 1.2 mm thick Tk. 67.20 Tk. 65.10 Tk. 68.25 per rft.
272 49.20 mm, 26.20 mm shutter lock of 1.2 mm thick Tk. 75.60 Tk. 73.50 Tk. 77.70 per rft.
PWD SoR 2014 for Civil Works 19
273 34.40 mm, 32.10 mm, 25.40 shutter inter lock of 1.2 mm thick Tk. 79.80 Tk. 77.70 Tk. 81.90 per rft.
274 31.75 mm shutter divider of 1.2 mm thick Tk. 63.00 Tk. 60.90 Tk. 64.05 per rft.
275 31.00 mm, 26.00 mm sliding fixed side of Tk. 48.30 Tk. 46.20 Tk. 49.35 per rft.
276 7.14 mm spandrel of 1.4mm to 1.2mm thick Tk. 70.35 Tk. 68.25 Tk. 72.45 per rft.
277 75.50 mm, 32 mm outer bottom (high) of 1.2 mm thick Tk. 78.75 Tk. 76.65 Tk. 80.85 per rft.
278 75.5 mm, 26.80 mm outer top of 1.2 mm thick Tk. 86.10 Tk. 82.95 Tk. 88.20 per rft.
279 37.78 mm, 31.78 mm bottom cover of 1.2 mm thick Tk. 33.60 Tk. 32.55 Tk. 34.65 per rft.
280 76.20 mm, 38.10 mm grouve cover of 1.2 mm thick Tk. 84.00 Tk. 81.90 Tk. 86.10 per rft.
281 57.15 mm, 15.80 mm grouve cover of 1.2 mm thick Tk. 49.35 Tk. 48.30 Tk. 50.40 per rft.
76.20 mm, 38.10 mm, 57.15 mm fixed top & side of 1.2 mm
282 Tk. 101.85 Tk. 98.70 Tk. 103.95 per rft.
thick
283 38.88 mm, 36.63 mm casement outer 1.2 mm thick Tk. 54.60 Tk. 52.50 Tk. 55.65 per rft.
286 57.15 mm, 15.80 mm grouve cover of 1.2 mm thick Tk. 49.35 Tk. 49.35 Tk. 50.40 per rft.
287 17.40 mm, 31.78 mm bottom cover of 1.2 mm thick Tk. 33.60 Tk. 32.55 Tk. 34.65 per rft.
288 76.20 mm, 38.10 mm fixed bottom cover of 1.2 mm thick Tk. 84.00 Tk. 81.90 Tk. 86.10 per rft.
289 57.15 mm, 38.10 mm top & side of 1.2 mm thick Tk. 101.85 Tk. 98.70 Tk. 103.95 per rft.
290 76.00 mm, 38.10 mm wall frame of 1.2 mm thick Tk. 75.60 Tk. 73.50 Tk. 77.70 per rft.
291 55.02 mm, 37.39 mm louver Z-section of 1.2 mm thick Tk. 31.50 Tk. 30.45 Tk. 32.55 per rft.
292 39.67 mm, 15.06 mm louver U-section of 1.2 mm thick Tk. 36.75 Tk. 35.70 Tk. 37.80 per rft.
293 95.00 mm, 38.00 mm outer bottom of 1.2 mm thick Tk. 103.95 Tk. 100.80 Tk. 106.05 per rft.
294 95.00 mm, 28.50 mm outer top of 1.2 mm thick Tk. 107.10 Tk. 103.95 Tk. 109.20 per rft.
295 95.00 mm, 19.50 mm outer side of 1.2 mm thick Tk. 81.90 Tk. 79.80 Tk. 84.00 per rft.
PWD SoR 2014 for Civil Works 20
296 42.2 mm, 13.2 mm net section of 1.2 mm thickness Tk. 53.55 Tk. 51.45 Tk. 54.60 per rft.
297 1" x 1" square pipe Tk. 50.40 Tk. 48.30 Tk. 51.45 per rft.
298 7.14 mm span drel of 1.2 mm thick (0.70 kg/m) Tk. 70.35 Tk. 68.25 Tk. 72.45 per rft.
299 Mosquito net (fiber net) (per sft.) Tk. 15.75 Tk. 15.75 Tk. 16.80 per rft.
300 T-section (main T) for false ceiling Tk. 22.05 Tk. 21.00 Tk. 23.10 per rft.
301 T-section (cross T) for false ceiling Tk. 22.05 Tk. 21.00 Tk. 23.10 per rft.
302 L-section for wall and ceiling Tk. 22.05 Tk. 21.00 Tk. 23.10 per rft.
303 Aluminium curtain rail in/c hard-wares and fittings Tk. 22.05 Tk. 21.00 Tk. 23.10 per rft.
304 44 mm, 44 mm, 1.20 box Tk. 72.45 Tk. 70.35 Tk. 74.55 per rft.
305 25 mm, 25 mm, 1.20 angle Tk. 22.05 Tk. 21.00 Tk. 23.10 per rft.
306 25 mm, 25 mm, 1.20 fitting angle Tk. 38.85 Tk. 37.80 Tk. 39.90 per rft.
307 Alluminium composite Panel Tk. 238.73 Tk. 236.25 Tk. 242.55 per rft.
308 Curtain wall sub mullium (100mm X 50 mm X 2.00 mm) Tk. 324.45 Tk. 315.00 Tk. 329.70 per rft.
309 Curtain wall sub mullium (50mm X 50 mm X 1.50 mm) Tk. 206.85 Tk. 200.55 Tk. 211.05 per rft.
310 Casement outer frame (29mm X 20 mm X 1.20 mm) Tk. 33.60 Tk. 34.65 Tk. 34.65 per rft.
311 Casement outer section (52mm X 22 mm X 40mm X 1.5 mm) Tk. 155.40 Tk. 152.25 Tk. 158.55 per rft.
312 Aluminium angle (50mm X 50 mm X 6mm) Tk. 180.60 Tk. 178.50 Tk. 183.75 per rft.
313 Aluminium cover (50mm X 6 mm X 1.5mm) Tk. 64.54 Tk. 61.95 Tk. 66.15 per rft.
314 50mm X 6 mm X 1.5mm angle for casement shutter Tk. 55.26 Tk. 57.75 Tk. 56.70 per rft.
315 38mm x 38mm Aluminium frame (Wall box) of 1.5 mm Tk. 41.30 Tk. 42.00 Tk. 42.00 per rft.
317 20 mm Aluminium pipe Tk. 88.20 Tk. 86.10 Tk. 90.30 per rft.
PWD SoR 2014 for Civil Works 21
353 Rod tilt / Hexagon Aluminium Rod Tk. 8.05 Per rft.
354 End cap set / End closure set Tk. 61.20 Per set
364 Glass fiber Fabrics (special quality, foreign made) Tk. 88.62 Per sft.
369 Aluminium Strips (special quality, foreign made) Tk. 74.42 Per rft.
370 Rod till / Hexagon Aluminium Rod Tk. 5.43 Per rft.
PWD SoR 2014 for Civil Works 23
379 Bottom cap / End Cap for head rail Tk. 9.97 each
C16 PVC
385 Wall grade 3/4" dia pipe, 1.2mm thick Tk. 3.92 Per rft.
386 Wall grade 1" dia pipe, 1.2mm thick Tk. 5.48 Per rft.
387 Roof grade 3/4" dia pipe, 1.5mm thick Tk. 4.97 Per rft.
388 Roof grade 1" dia pipe, 1.5mm thick Tk. 6.19 Per rft.
389 Roof grade 1.25" dia pipe, 1.5mm thick Tk. 8.84 Per rft.
401 PVC door frame thickness min 2.5 mm Tk. 104.69 Per meter
402 G.I inner joint (76.2 mm x 38.1 mm) clamp Tk. 11.22 each
403 G.I inner joint (72.2 mm x 76.2 mm) clamp Tk. 13.02 each
408 uPVC hollow section wall thickness 2.5 mm Tk. 862.40 Per meter
463 Rowl plug (10 Nos. per pack) Tk. 18.43 Per pack
II. Consumable
495 5/8" x 3" long nut bolt in/c washer Tk. 95.61 each
496 Valve Pit (Titas Gas T&D Co. Ltd. design & plan.) (for 2" dia above) Tk. 15,154.70 each
497 M.S. sheet cover supplied by Titas Gas T & D Co. Ltd.(for 2" dia above) Tk. 13,492.37 each
499 50 mm ND dia ball valve class 150 R.F. Tk. 7,000.40 each
500 25 mm ND dia plug valve class 150 R.F. Tk. 4,540.80 each
PWD SoR 2014 for Civil Works 28
506 3/4" dia G.I. pipe (NTL or eqv.) Tk. 60.80 Per rft.
507 1/2" dia G.I. pipe (NTL or eqv.) Tk. 51.25 Per rft.
513 70 mm non load bearing concrete hollow block Tk. 21.23 each
516 90 mm non load bearing concrete hollow block Tk. 24.00 each
518 140 mm non load bearing concrete hollow block Tk. 33.46 each
520 140 mm load bearing concrete hollow block Tk. 48.75 each
521 190 mm load bearing concrete hollow block Tk. 59.61 each
535 250 x 250 mm Grey Engraved CC tiles Tk. 40.57 Per sft.
536 250 x 250 mm colored Engraved CC tiles Tk. 49.14 Per sft.
540 Transportation Solid block (215 x 100 x 65) mm Tk. 1.64 each
541 200 x 92 x 37.5 mm grey solid cladding block Tk. 12.19 each
543 200 x 92 x 37.5 mm colored solid cladding block Tk. 8.96 each
548 418 x 330 x 17 mm red color roof tiles Tk. 41.07 each
551 418 x 330 x 17 mm oriental color roof tiles Tk. 37.01 each
552 418 x 330 x 17 mm antique red color roof tiles Tk. 42.65 each
553 418 x 330 x 17 mm green color roof tiles Tk. 46.40 each
556 100 mm non-load bearing concrete hollow block Tk. 26.68 each
564 418 x 330 x 17 mm brown color roof tiles Tk. 43.00 each
565 418 x 330 x 17 mm Navy blue roof tiles Tk. 45.97 each
566 418 x 330 x 17 mm Mahogany color roof tiles Tk. 43.08 each
567 418 x 330 x 17 mm Rust Gold color roof tiles Tk. 42.97 each
568 All type Concrete Ridge: red color Tk. 130.95 each
I. Misc. items
571 Water sealed heavy type 18" dia C.I. M.H. cover having locking arrangement Tk. 1,026.84 each
593 32 mm dia plastic pipe for low-down connection Tk. 79.77 each
White Combicloset, Size (mm) 700 x 410 x 795. (BISF Item No. 115A/415A or
594 equivalent) Tk. 3,622.50 each
605 White long pan, Size approx.585x445x290, 12.5kg Tk. 484.15 each
608 White/colored foot-rest, Size (mm) 260 x 227 x 25. 280x140x30,1.5kg Tk. 80.50 Per pair
609 BISF White W-basin, 600x465x225,14kg 580 x 445 x 235. Tk. 1,147.00 each
612 White W-basin in/c pedastal, Size (mm) 656x510x845, 26kg 570 x 420 x 190. Tk. 4,000.00 each
619 32 mm dia PVC waste pipe for W-Basin connection Tk. 158.12 each
621 BISF White Pedestal, Size (mm) approx. 670x186x170, 6.5kg 652x 200 x 205. Tk. 763.00 each
624 BISF White Bowl Urinal, Size (mm) 485 x 360 x 290, 9kg Tk. 943.00 each
627 White Flat/Squat. Urinal, Size (mm) approx510 x 380 x 85 Tk. 869.00 each
629 Special colored Flat/Squatting Bowl Urinal: -do- Tk. 959.00 each
630 White porcelain Sink, Size (mm) 635x 480x195, 19.5kg Tk. 2,024.00 each
632 Stainless steel, Single Bowl Sink: Singapore/M'Asia, Size (mm) 450 x 1050 Tk. 2,596.49 each
633 Stainless steel, double Bowl Sink: Singapore/M'Asia, Tk. 4,906.22 each
636 Super quality steel frame with brackets for 600 x 125 x 5 mm size Glass Shelf Tk. 586.08 each
637 Super quality colored Glass for -do- Tk. 326.00 each
Medium quality CP iron frame with brackets for 600 x 125 x 5 mm size Glass
638 Tk. 305.00 each
Shelf.
640 Super Quality 600 x 20 mm dia size CP Towel Rail. Tk. 417.44 each
642 BISF White Porcelain Toilet Paper Holder, Size (mm) 150 x 150 x 126 Tk. 126.00 each
643 Special Porcelain Toilet Paper Holder: -do- Tk. 155.00 each
644 Standard size Stainless Steel Toilet Paper Holder with Cover Tk. 270.96 each
645 Standard size CP Toilet Paper Holder with Plastic Holder rod Tk. 216.02 each
648 150 x 150mm size Plastic-Grating with hinged Cover Tk. 187.18 each
649 Plastic low down complete set in/c internal and external fittings Tk. 1,066.59 per set
650 Internal and external fittings for plastic low down Tk. 568.91 per set
(a) HCI
655 50 mm dia HCI pipe: 1.83 m long Tk. 1,005.10 Per pc.
658 100 mm dia HCI pipe: 1.83 m long: Tk. 2,095.26 Per 6'-0" pc.
660 100 mm dia HCI Tee/T-Y/Y (100 x 100/50 mm) Tk. 788.83 each
661 150 mm dia HCI pipe: 1.83 m long Tk. 2,899.65 Per pc.
PWD SoR 2014 for Civil Works 34
663 150 mm dia HCI Tee/T-Y/Y (50 x 50 mm) Tk. 1,424.70 each
665 HCI 100 x 100 or 100 x 50 mm or T-Y Cleanout Tk. 785.85 each
666 HCI 150 x 150 or 150 x 100 mm or T-Y or Y-Cleanout Tk. 813.74 each
(b) uPVC
691 50 mm dia uPVC Pipe: 20 rft (6m) long Tk. 896.75 Per pc.
710 100 mm dia uPVC Pipe: 20 rft (6m) long Tk. 2,083.78 Per pc.
712 100 mm dia uPVC Tee/T-Y/Y (50 x 50 mm) Tk. 457.94 each
715 110 mm dia uPVC plain bend 900 Tk. 207.72 each
719 150 mm dia uPVC Pipe: 20 rft (6m) long Tk. 2,719.83 Per pc.
721 150 mm dia uPVC Tee/T-Y/Y (50 x 50 mm) Tk. 1,048.44 each
722 150 mm dia uPVC for under-ground Tk. 211.47 Per rft.
723 200 mm dia uPVC pipe for under-ground Tk. 289.14 Per rft.
724 250 mm dia uPVC pipe for under-ground Tk. 419.11 Per rft.
725 280 mm dia uPVC pipe for under-ground Tk. 525.55 Per rft.
726 315 mm dia uPVC pipe for under-ground Tk. 755.23 Per rft.
(b) CPVC
(b) ABS
841 62 mm dia stainless steel (2 mm thick) pipe Tk. 304.54 Per rft.
842 50 mm dia stainless steel (2 mm thick) pipe Tk. 250.85 Per rft.
843 40 mm dia stainless steel (2 mm thick) pipe Tk. 198.68 Per rft.
844 25 mm dia stainless steel (2 mm thick) pipe Tk. 136.19 Per rft.
845 20 mm dia stainless steel (2 mm thick) pipe Tk. 93.91 Per rft.
846 12 mm dia stainless steel (2 mm thick) pipe Tk. 83.65 Per rft.
847 6 mm dia stainless steel (1.5 mm thick) pipe Tk. 70.79 Per rft.
858 150 mm dia RCC pipe (stone-chips, 40 mm thickness. 6'-0" long) Tk. 1,017.00 each (6'-0")
859 225 mm dia RCC pipe: -do- Tk. 1,575.00 each (6'-0")
860 300 mm dia RCC pipe (stone-chips, 50 mm thickness. 6'-0" long) Tk. 2,743.00 each (6'-0")
861 375 mm dia RCC pipe (stone-chips, 50 mm thickness. 6'-0" long) Tk. 3,580.00 each (6'-0")
862 900 mm dia RCC pipe (stone-chips, 100 mm thickness. 6'-0" long) Tk. 13,190.00 each (6'-0")
V. G.I. Gate-Valve
VIII. Float-Valve
905 HCI 100 x 100 or 100 x 50 mm or T-Y cleanout Tk. 749.58 each
906 HCI 150 x 150 or 150 x 100 mm T-Y or Y cleanout Tk. 1,139.22 each
X. Faucets
915 12 mm plastic bip cock with internal brass thread Tk. 136.80 each
927 CP shower mixture in/c shower head & faucet Tk. 3,866.37 each
930 12 mm ordinary type (brass) for surface mount CP stop cock Tk. 229.54 each
938 12 mm medium quality concealed angle stop cock Tk. 636.47 each
940 Special concealed type heavy stop cock Tk. 766.53 each
941 12 mm CP medium quality surface & heavy type angle stop cock Tk. 512.50 each
942 12 mm CP surface special heavy type stop cock Tk. 399.97 each
943 100 mm dia CP fixed type cleansing shower rose Tk. 435.21 each
944 100 mm dia CP moving type cleansing shower rose Tk. 652.79 each
947 16 BWG GI 1200 x 1200 x 1200 mm size over-head water-tank Tk. 10,753.51 each
948 18 BWG GI 1200 x 1200 x 1200 mm size over-head water-tank Tk. 10,706.72 each
949 1000 liter food-grade Plastic over-head water-tank Tk. 9,800.00 each
950 1500 liter food-grade Plastic over-head water-tank Tk. 14,700.00 each
951 2000 liter food-grade Plastic over-head water-tank Tk. 19,600.00 each
952 150 liter capacity plastic mini tank (loft tank) Tk. 1,950.00 each
953 300 liter capacity plastic mini tank (loft tank) Tk. 3,690.00 each
954 500 liter capacity plastic mini tank (loft tank) Tk. 5,000.00 each
955 500 liter capacity stainless steel water tank Tk. 7,640.93 each
956 1000 liter food-grade stainless steel water tank Tk. 14,036.63 each
PWD SoR 2014 for Civil Works 45
957 2000 liter food-grade stainless steel water-tank Tk. 24,056.59 each
958 4000 liter food-grade stainless steel water tank Tk. 49,191.06 each
959 6000 liter food-grade stainless steel water tank Tk. 53,481.79 each
960 400 Gallon capacity Ferro-cement water tank Tk. 6,320.90 each
961 450 mm long metal cover connection pipe Tk. 266.46 each
962 600 mm long metal cover connection pipe Tk. 307.52 each
963 1/2"or 3/4" dia ball cock for water tank Tk. 231.50 each
964 3/4" dia overflow pipe with jam-nut for plastic water tank Tk. 122.37 each
965 12 mm dia & 450 mm long plastic flexible connection pipe Tk. 48.74 each
966 12 mm dia & 600 mm long plastic flexible connection pipe Tk. 57.62 each
967 11 liter capacity/50 GPD Reverse Osmosis water Purifier Tk. 16,998.58 each
968 10 liter capacity/75 GPD Reverse Osmosis water Purifier(without meter) Tk. 20,063.85 each
969 10 liter capacity/75 GPD Reverse Osmosis water Purifier(with meter) Tk. 21,205.04 each
970 17 liter capacity/100 GPD Reverse Osmosis water Purifier: (hot, cold, warm Tk. 63,809.24 each
options)
971 400 gal capacity ferro-cement water tank in/c installation Tk. 7,251.45 each
976 16'-0" long muli bamboo (For split) Tk. 75.00 each
977 25'-0" long muli bamboo (Full size) Tk. 130.00 each
993 Steel funna, 18" size wirth wooden handle Tk. 200.00 each
998 22 BWG G.I. water can (2.5 gallon) Tk. 250.00 each
1000 ¾" dia plastic hose pipe Tk. 15.00 per rft.
1001 3.75 h.p. 22" blade 4 stroke, finger trip Lawn Mower Machine: YARDMAN No. Tk. 40,000.00 each
060A
1002 16" blade Hand Lawn Mower, Model No. 1403 – 16 (USA) Tk. 10,500.00 each
1003 Mobilization of equipment for drilling 38 mm dia test and observation well Tk. 5,856.91 L.S.
1005 Best quality heavy type hand type pump No. 6 Tk. 2,182.00 each
1006 2.91 mm wall thick 38 mm dia G.I. pipe Tk. 486.41 meter
1007 38 mm dia water grade PVC pipe (D-Class or eqv.) in/c carriage Tk. 95.65 meter
1008 36 mm dia water grade PVC Strainer (D-Class or eqv.) in/c carriage Tk. 111.80 Meter
1011 Complete development of the tube-well (test boring) up to 200 m depth. Tk. 5,150.37 L.S.
1015 Maintaining and filling and sealing test bore Tk. 2,961.76 Each bore
1016 Mobilization of drilling rig for shrouded production wells of depth up to 100 m Tk. 29,392.65 L.S.
1042 Complete development of the tube-well up to 200 m depth (50 x 150 mm tube- Tk. 18,573.48 LS.
well).
1047 Hire charge of pump in/c spare and maintenance Tk. 230.24 Hour
1049 150 mm dia and 4 mm thick M.S. pipe Tk. 1,952.98 meter
1050 200 mm dia and 6 mm thick M.S. pipe welded Tk. 2,900.27 meter
1051 200 mm dia and 6 mm thick M.S. pipe seamless Tk. 3,200.93 meter
1056 150 mm dia 4.85 mm thick G.I. pipe Tk. 2,462.63 meter
1058 150 mm dia stainless steel strainer of continuous slot Tk. 12,117.41 meter
1059 150 mm dia 2.5 mm thick stainless steel bridge type strainer Tk. 8,644.03 meter
1060 200 mm dia stainless steel strainer of continuous slot Tk. 13,856.05 meter
1061 200 mm dia 2.5 mm thick stainless steel bridge type strainer Tk. 8,831.97 meter
1062 75 mm dia 2.5 mm thick stainless steel bridge type strainer Tk. 5,618.07 meter
PWD SoR 2014 for Civil Works 49
1063 100 mm dia 2.5 mm thick stainless steel bridge type strainer Tk. 5,546.52 meter
1064 50 mm dia 2.5 mm thick stainless steel bridge type strainer Tk. 4,549.91 meter
1065 75 mm dia 2.5 mm thick stainless steel bridge type strainer Tk. 6,179.02 meter
1066 150 mm x 300 mm dia 6 mm thick M.S. reducer Tk. 8,688.87 each
1071 (i) 300 mm dia 6 mm thick M.S. Housing pipe welded Tk. 5,037.14 meter
1072 (ii) 300 mm dia 6 mm thick M.S. Housing pipe seamless Tk. 8,178.48 meter
1073 (iii) 400 mm dia 6 mm thick M.S. Housing pipe welded Tk. 9,017.14 meter
1074 (iv) 400 mm dia 6 mm thick M.S. Housing pipe seamless Tk. 11,042.23 meter
1075 150 mm dia 6 mm thick M.S. Housing pipe welded Tk. 2,549.97 meter
1076 150 mm dia 6 mm thick M.S. Housing pipe seamless Tk. 2,639.54 meter
1081 EPI / RFL (medium) brand No. 6 Pump with necessary fittings etc. Tk. 2,277.00 each
III. Testing of water in/c arsenic, collected from the test bore in BUET
Laboratory
1105 Sieve analysis for sand from different layer Tk. 1,123.00 Per test
I. Operational cost
1106 Truck fare within 20 km in/c loading & un-loading Tk. 1,000.00 Per trip
1107 Temporary camp at site for soil investigation work Tk. 1,053.00 Per site
1108 Field Engineer in/c site allowances: 1-3yrs Exp, Membersip with IEB Tk. 1,438.00 Per day
1109 Foundation Engineer: 5-10yrs exp , Membership with IEB Tk. 2,156.00 Per day
1111 Rig operators in/c site allowances Tk. 603.00 Per day
1112 Helper to rig operator/c site allowances Tk. 375.00 Per day
1113 Unskilled labour in/c site allowances Tk. 313.00 Per day
1124 Hydrometer, sieve analysis & sp. gr.,& Classification according to ASTM Tk. 875.00 Per test
1131 Unit weight (wet & dry) Tk. 188.00 Per test
1140 Consolidated drain test (direct shear test) Tk. 1,000.00 Per test
1142 Consolidated quick test (direct shear test) Tk. 875.00 Per test
PWD SoR 2014 for Civil Works 52
1143 Consolidated un-drained tri-axial test with pore pressure Tk. 2,875.00 Per test
1144 Consolidated un-drained tri-axial test without pore pressure Tk. 875.00 Per test
1146 Unconsolidated quick test (direct shear test) Tk. 1,000.00 Per test
1147 Unconsolidated un-drained tri-axial test (without pore pressure) Tk. 1,000.00 Per test
1148 Field density in/c field visit (for non-cohesive soil) Tk. 1,875.00 Per test
1149 Field Vanshear test in cohesive soil (ASTM D-2573-72, 1978) Tk. 1,750.00 Per test
1151 One dimensional swelling/settlement potential of co-hesive soil Tk. 1,875.00 Per test
1152 Non-repetitive static plate load test of soil (ASTM S-1196-64, reaapproved in Tk. 1,750.00 Per test
1977)
1153 Visual Inspection & Classification of soil for engineering purposes Tk. 94.00 Per test
C24 FITTINGS
1179 Best quality round lock/ rim lock Tk. 610.00 each
1182 10" long & 1/2 dia tower bolt Tk. 34.00 each
1186 6" long brass tower & socket bolt Tk. 241.00 each
1197 1.5 mm thick corrugated fiber glass Tk. 77.00 Per sft.
1198 1.5 mm thick fiber glass sheet ridging Tk. 117.00 Per rft.
1202 Top and bottom clamping device Tk. 1,014.00 Per set
1218 Empty gunny bags/ Polymer bag to fill sand for load test Tk. 9.00 each
1220 Copper sheet for expansion joint Tk. 198.00 Per sft.
1221 Aluminum sheet for expansion joint Tk. 144.00 Per sft.
PWD SoR 2014 for Civil Works 55
1223 100 mm dia HCI rain pipe Tk. 1,719.00 Per 6'-0"
1229 1.5" dia M.S. wheel for collapsible gate Tk. 23.00 each
1234 1.5 inch dia heavy type gate wheel Tk. 145.00 each
1239 China made spring for rolling shutter Tk. 24.00 Per rft.
1243 6" long brass tower & socket bolt Tk. 403.00 each
1262 Single layer double bamboo tarja Tk. 121.00 per sqm
1266 2.44 m x 1.22 m size hard board Tk. 588.00 per piece
1270 Sign board in/c material, painting,lettering etc all complete Tk. 200.00 sft
1273 As built work survey & report Tk. 1,500.00 per day
Providing Expertised Architectect 5years exp with registration in respective Tk. 60,000.00 per month
1274 professional body
1280 Engineer, min graduate in relevant field Tk. 1,200.00 per day
1281 Diploma Engineer, min 5yrs Exp Tk. 1,200.00 per day
1282 Diploma Engineer, min 1yrs Exp Tk. 750.00 per day
1284 Royality of Dredge material in the water body Tk. 650.00 per thousand cft
PDA Test: Striking hammer, guide, trip gear etc in/c carriage, saftey &
1285 Tk. 20,000.00 each per day
insurance
1286 PDA TEST : Lifting device including carraige, saftey & insurance Tk. 20,000.00 each per day
PDA Test: Data acquisition unit, sensors etc including carriage, saftey & Tk. 50,000.00 each per day
1287 insurance
1289 Cutting by oxy-ace of 1/2" M.S plate, top & bott plate Tk. 15.00 tk/rft
1290 1/2 th MS Plate Grinding to V bevel top & bott Tk. 100.00 tk/rft
1291 1" dia Hole in 1/2" M.S plate Tk. 20.00 p/nos
Cutting by shearing granding and hole for steel jacket, 1/4" plate on 2U x ( top Tk. 10.00 tk/rft
1292 & bott) - C or U form
1293 1/4 th MS Plate Grinding to V bevel on faces of U legs for top & bott Tk. 60.00 tk/rft
1295 2" dia Hole in 1/4" M.S plate Tk. 15.00 p/nos
1296 1.5" G.I / MS pipe for dowel bar Tk. 160.00 tk/rft
1298 Data logging Engineer at Hydraulic pile driver Tk. 1,500.00 per day
1299 Chief Mechanic, at Hydraulic pile driver Tk. 1,200.00 per day
1300 Helper to mechanic, at Hydraulic pile driver Tk. 388.00 per day
1302 Crane Operator, at Hydraulic pile driver Tk. 1,000.00 per day
1303 Asst. Crane Operator, at Hydraulic pile driver Tk. 732.00 per day
PWD SoR 2014 for Civil Works 58
1304 Machine Operator, at Hydraulic pile driver Tk. 1,000.00 per day
1305 Asst machine operator, at Hydraulic pile driver Tk. 732.00 per day
1306 Helper to crane operator, at Hydraulic pile driver Tk. 388.00 per day
1307 Helper to machine operator, at Hydraulic pile driver Tk. 388.00 per day
1308 Generator Operator, at Hydraulic pile driver Tk. 732.00 per day
1309 Surveyer to pile layout , at Hydraulic pile driver Tk. 1,000.00 per day
1310 Helper to surveyer, at Hydraulic pile driver Tk. 732.00 per day
1311 Skilled Labor, at Hydraulic pile driver Tk. 303.00 per day
1312 ordinary labor, at Hydraulic pile driver Tk. 245.00 per day
Compilation of driving Report, Pile Capacity log & submission to PE on signing Tk. 10,000.00 per day
1313 it on Hydraulic pile driver
1314 Each additional copy, at Hydraulic pile driver Tk. 500.00 per day
1320 Laboratory Charges for Testing Materials: Please find the Division 32 A and 32 B.
Carriage of materials except bricks and bats by motor trucks bullock carts or
1 any other means, in/c. loading, unloading at both ends and stacking properly
at site as per direction of the Engineer.
(d) For each additional km beyond 5.0 kilometer and up to 30.0 kilometer Tk. 16.00 Per M. ton
(e) For each additional km beyond 30.0 kilometer and up to 80.0 kilometer Tk. 11.00 Per M. ton
2. Weighing at both ends for items of steel materials only Tk. 94.00 Per M. ton
Carriage of bricks or bats by motor truck, bullock carts or any other means
3. in/c. loading, unloading at both ends and stacking properly at site as per
direction of the Engineer.
(d) For each additional km beyond 5.0 kilometer and up to 30.0 kilometer Tk. 23.00 Per % 0 Nos.
(e) For each additional km beyond 30.0 kilometer and up to 80.0 kilometer Tk. 16.00 Per % 0 Nos.
SCHEDULE OF RATES
FOR CIVIL WORKS
PWD SoR 2014 for Civil Works 60
01.1 Erection and maintenance of site office and removal the same after completion
of work in accordance with the conditions of contract. In addition to the office
required for his own use, the Contractor shall provide and maintain furnished field
office for the use of the Engineer and his staff. The field office is to have a concrete
floor, adequate foundation, brick walls, false ceiling of hard board with seasoned
Garjan wood frame and painted, and all windows are to be glazed and provided with
steel grill. Outside and inside wall surface are to be painted on plaster acceptable to
the Engineer. The field office shall be maintained in a secure and watertight condition
by the Contractor until the completion of the contract and shall be provided with
electricity, running water and sewerage. All doors shall be fitted with approved locks
and windows shall be provided with screen/blinds. Before construction the Contractor
shall submit plans and drawings showing proposed details and location for the field
office, including foundations, access roads, shades, layout of electrical and water
supply and hard standings thereto for the approval of the engineer. The Engineer
may require revision of the plans prior to giving approval for construction. The
Contractor shall also submit details proposed furniture, fittings and other items of
equipment and plant to the engineer for approval. These items shall be of the
standard quality suitable for site. The office, complete with furnishings, fittings,
access roads and hard standings shall be ready for occupation by the Engineer
within 28 days of the date when the Contractor first occupies the site. The Contractor
will provide day and night guards and a tea boy for the field office. At the end of the
project all materials, equipment and plant, furniture, fittings recovered from
dismantling the office and removing access road will be the property of the
Contractor. No interim payment shall be certified unless Engineer’s office with
required facilities are constructed and accepted by the Engineer.
(This is a time related item. Proportionate payment for this item shall be made
distributing in each bill on the basis of percentage progress of the whole works under
contract)
01.1.1 Engineer’s site office of minimum 15 sqm plinth area with providing furniture, first aid- L.S. Tk. 125,251.00
box, safety helmet, level / theodolite, consumables, stationeries etc.
01.1.2 Engineer’s site office of minimum 38 sqm plinth area with providing security fencing, L.S. Tk. 389,014.00
5 Kva stand-bye generator, furniture, first aid-box, safety helmet, level / theodolite,
consumables, stationeries etc.
01.1.3 Engineer’s site office of minimum 38 sqm plinth area with providing security fencing, L.S. Tk. 502,145.00
5 Kva stand-bye generator, IBM compatible PC with monitor, uninterruptible power
supply (UPS), Laserjet printer (minimum 25 ppm), furniture, first aid-box, safety
helmet, level/theodolite/EDM, consumables, stationeries etc.
01.1.4 Engineer’s site office of minimum 38 sqm plinth area with providing security fencing, L.S. Tk. 534,467.00
5 Kva stand-bye generator, IBM compatible PC with monitor, uninterruptible power
supply (UPS), Laserjet printer (minimum 25 ppm), photocopier, 6 cft. Freeze,
furniture, first aid-box, safety helmet, level/theodolite/EDM, consumables,
stationeries etc.
PWD SoR 2014 for Civil Works 61
01.1.5 Engineer’s site office of minimum 10 sqm plinth area with providing furniture, first aid- L.S. Tk. 23,916.00
box, safety helmet, consumables, stationeries etc for low value simple work of short
duration (not more than six months).
01.1.6 Providing and maintenance window type 1800 BTU AC (Air-Cooler) for each Tk. 52,871.00
Engineer’s office and remove after completion of contract.
01.1.7 Providing and maintenance one project profile signboards of the size not sqm. Tk. 207.00
exceeding 1 m x 2 m, to be placed at a suitable place of the site including
submission of proposals for the materials of the signboards and text layout to the
Engineer for approval which will be positioned as directed by the Engineer and
removing the same on completion of the Works or as instructed by the Engineer.
01.2.1 Providing 3 sets as-built Drawings subject to Engineer’s approval produced in Per Tk. 19,451.00
AutoCAD software in 23.38” x 16.54” (A-2 size) standard drawing paper, and tender
operating and maintenance manual of the equipment and plant incorporated in the
works, if any, in original by the date stated in the Particular Conditions of Contract
(PCC). If the Contractor does not supply the as-built drawings and operating and
maintenance manuals by the date stated in the Particular Conditions of Contract
(PCC), or they do not receive the Engineer’s approval, the Engineer shall withhold
the amount stated in the PCC from the payments due to the Contractor.
The as-built drawings must show the permanent works as actually constructed and
reflect the revision of Tender Drawings and Drawings supplied to the Contractor
during the Contract as well as revisions of drawings supplied by the Contractor
during the Contract.
(One set of as-built drawings shall be considered for measurement and payment)
01.2.2 Providing additional copy of as-built drawing produced in AutoCAD software in sqm of Tk. 267.00
23.38" x 16.54" (A-2) standard drawing paper accepted by the Engineer. drawing
sheet
01.2.3 Providing minimum ten (10) copies coloured post-card size progress photograph of month Tk. 42.00
‘works under contract’ taken by professional photographer which record the progress
of the Works.
01.2.4 Preparation & submission of implementation schedule to the Engineer for approval Per Tk. 29,165.00
prior ground breaking showing the events (works) and successive sub-events of tender
works including all the management & control parameters like Earliest Start Time
(EST), Earliest Finish Time (EFT), float events on critical path, resource allocation
etc. with description of general method of works, in orderly manner all in the form
network diagram prepared in computer software like MS project and presenting in
Displayable hard and soft copy minimum 3 (three) sets.
(This is a time related item. Proportionate payment for this item shall be made
distributing in each bill on the basis of percentage progress of the whole works under
contract)
01.2.5 Updating the Implementation Schedule and submission to the Engineer at month Tk. 12,371.00
intervals no longer than 28 days showing actual physical and financial progress
achieved, on each activity and the effect of the progress on the timing of the
remaining work, including any changes to the sequence of the activities.
However, Engineer’s approval of the Programme shall not alter the Contractor’s
obligations. The Contractor may revise the Programme and submit it to the Engineer
again at any time. A revised programme shall show the Variations and Events
related to change of contract price. Month wise documentation shall be the basis
of payments on this item
PWD SoR 2014 for Civil Works 62
01.2.6 Providing all necessary logistic support to frame ‘monthly progress meeting’ month Tk. 1,802.00
between Contractor/Contractor’s representatives and Employer / Employer’s
representatives at the Engineer's office at site. Month wise documentation shall be
the basis of payments on this item
01.3 Providing layout and carry over PWD Bench-Mark (BM) at site from nearby BM sqm. Tk. 4.00
pillar, Property lines, existing ground level (EGL), formation ground level (FGL),
highest flood levels (HFL), plinth levels (PL), mean sea level (MSL), setting and
marking all pillars, marker, pegs etc. showing and maintaining reduced levels (RL’s)
including locating, establishing, protecting all public utilities within the premise of
work and finally all to be presented in black and white.
01.4 Mobilization and cleaning site before commencing actual physical work and during sqm. Tk. 21.00
contract period and demobilization after completion of the Works under contract
accepted by Engineer.This work shall also covers clayey cleaning and clearing,
cutting or filling, dressing the project area on and in the ground to an extent that all
the events of works of the project can be executed smoothly in a working
environment with a particular attention on safety and security in all respects, and to
stockpile the end outcome to a place for disposal agreed by the Engineer, where,
payments are to be based on ground area determined by the Engineer and be
proportionate to the percentage progress of work under contract as a whole in all
respects and approved by the Engineer.
1.5 Providing Expertised architect having relevant experience (s) more than 5years for Per Tk. 60,000.00
detail documentation of architectural themes, drawings, workingout shop drawings, month
communication with theme architect & getting approval , specifying architectural
needs according to approved master architectural themes & plan, certifying as built
drawing for the approval etc & jobs assigned by the HOPE or his official at site
(max man month not greater than 1/4th of Project duration & payment for the item
subject to submission of CV & approved by approving authority)
1.6 Providing Expertised Engneer having relevant experience(s) more than 10years, for Per Tk. 100,000.00
the project documentation, progress study & adjustment, preparation of project month
Material schedule and Testing schdule for approval etc. & jobs assigned by the
HOPE or his official, at site (max man month not greater than 1/4th of Project
duration & payment for the item subject to submission of CV & approved by
approving authority)
1.7 Pick - up (double Cab) for transport of Test samples, work samples & emmergency Per Tk. 65,000.00
services etc. in/c fuel etc. (total usage not more than 1/6th of project duration.) month
02.1 Earth work in excavation in all kinds of soil for foundation trenches including.
layout, providing center lines, local bench-mark pillars, leveling, ramming and
preparing the base, fixing bamboo spikes and marking layout with chalk powder,
providing necessary tools and plants, protecting and maintaining the trench dry etc.,
stacking, cleaning the excavated earth at a safe distance out of the area enclosed by
the layout etc. all complete and accepted by the Engineer, subject to submit method
statement of carrying out excavation work to the Engineer for approval. However,
Engineer’s approval shall not relieve the contractor of his responsibilities and
obligations under the contract.
02.1.1 Layout and marking for earthwork in excavation in foundation accepted by the sqm. Tk. 11.00
Engineer. [Plinth area of the structure shall be considered for measurement]
02.1.2 Earthwork in excavation in foundation trenches up to 1.5 m depth and maximum 10 cum Tk. 67.00
m lead: in soft clayey soil / loose sand / silt
02.1.3 Earthwork in excavation in foundation trenches up to 1.5 m depth and maximum 10 cum Tk. 96.00
m lead: in medium stiff clayey soil.
02.1.4 Earthwork in excavation in foundation trenches up to 1.5 m depth and maximum 10 cum Tk. 144.00
m lead: in very stiff (hard) clayey soil/ rubbish etc.
02.1.5 Earthwork in excavation in foundation trenches up to 1.5 m depth and maximum 10 cum Tk. 166.00
m lead: in very soft / saturated / organic clayey soil / soil of semi-liquid state.
02.1.6 Extra rate for each additional 0.5 meter depth exceeding 1.5 meter. cum Tk. 16.00
02.1.7 Extra rate for each 1 m additional lead beyond 10 m. cum Tk. 2.12
02.2 Bailing out trapped water caused by inundation due to sepage or rain, by a hour Tk. 333.00
pump of aprox. 25m3/h from foundation trenches, where correct
documentation on rain fall, sepage rate, volume of inandation shall strictly be
made.
02.3 Supplying of straight and strong borrak bamboo posts of having minimum 75 mm rm. Tk. 75.00
diameter althrough and driving the same vertically in the ground up to required depth
by any means shaping the top of the post, all complete and accepted by the
Engineer.
02.4 Supplying wooden ballah having an average diameter not less than 150 mm rm. Tk. 714.00
(without barks) at one third distance from larger end with a minimum end diameter of
100 mm for retaining purpose and driving to a depth as per design and drawing by
any method including all arrangement for staging, hoisting, carrying etc. complete
and accepted by the Engineer.
PWD SoR 2014 for Civil Works 64
02.5 Palisading work by supplying bitumen drum sheet walling tied with 20 BWG G.I. sqm. Tk. 596.00
wire fixing the same with already driven borrak bamboo posts with half split borrak
bamboo runners @ 450mm c/c horizontally with iron nails, G.I wire etc. all complete
and accepted by the Engineer. (Rate is excluding the cost of bamboo post).
02.6 Supplying and fitting-fixing horizontal bracing in Palisading with ½ split wooden rm. Tk. 269.00
ballah having an average diameter not less than 150 mm with a minimum end
diameter of 100 mm @ 450 mm including supply of iron nails, gazals etc. complete
approved and accepted by the Engineer.
02.7.1 Shore protection work during excavation in foundation trenches up to 1.5 m depth, sqm. Tk. 678.00
to protect loss due to damage of property by Palisading accepted by the Engineer.
[the rate is including cost of vertical post]
02.7.2 Shore protection work during excavation in foundation trenches to protect loss due sqm. Tk. 1,217.00
to damage of property by Palisading beyond 1.5 m depth accepted by the
Engineer [the rate is including cost of vertical post]
02.8 Supply and laying 2 mm thick Geo-textile of approved quality and sqm. Tk. 130.00
origin/manufacturer as per manufacturer’s instructions approved and accepted by the
Engineer. Before commencing lying of Geo-textile, the Contractor must submit the
method statement for carrying out this work including sample with evidence of origin
and compliance certificate from independent testing laboratory for approval.
02.9 Removing sludge or semi-liquid clay/substances etc not suitable for pumping out cum Tk. 678.00
or carrying by head load from the bottom of any marshy land, lake, ditch, pond by
mixing fine local sand of F.M. 0.8 or less to a proportion such that it can be carried to
an intermediate point of disposal and cutting the same including stacking and
spreading properly on a suitable place to dry in the sun for a certain days and
dispose the dried sludge or clay to a safe distance etc. complete and accepted by
the Engineer subject to submit method statement to the Engineer for carrying out the
works including ultimate disposal of the sludge under this item for approval. However
Engineer’s approval shall not relieve the Contractor of his responsibilities and
obligations under the contract.
02.10.1 Sand filling in foundation trenches and plinth with sand having F.M. 0.5 to 0.8 in cum Tk. 602.00
150mm layers including leveling, watering and compaction to achieve minimum dry
density of 90% with optimum moisture content (Modified proctor test) by ramming
each layer up to finished level as per design supplied by the design office only etc. all
complete and accepted by the Engineer.
02.10.2 Sand filling in foundation trenches and plinth with coarse sand having min. F.M. 1.2 cum Tk. 1,043.00
in 150mm in layers including leveling, watering and compaction to achieve minimum
dry density of 90% with optimum moisture content (Modified proctor test) by ramming
each layer up to finished level as per design supplied by the design office only etc. all
complete and accepted by the Engineer.
02.10.3 Sand filling in foundation trenches and plinth with coarse sand having min. F.M. 2.2 cum Tk. 1,760.00
in 150mm layers including leveling, watering and compaction to achieve minimum
dry density of 90% with optimum moisture content (Modified proctor test) by ramming
each layer up to finished level as per design supplied by the design office only etc. all
complete and accepted by the Engineer.
PWD SoR 2014 for Civil Works 65
02.11 50 mm down graded picked jhama Khoa consolidation in foundation trenches by cum Tk. 3,652.00
mixing the same with best quality local sand (F.M. 1.2) in (2:1) (khoa: sand)
proportion to achieve minimum dry density of 90% with optimum moisture content
(Modified proctor test) including breaking and screening chips,laying and spreading
in150mm layers uniformly and compacting etc. all complete and accepted by the
Engineer.
02.12 50 mm down graded picked jhama khoa consolidation in foundation trenches by cum Tk. 4,508.00
mixing in mixer machine in foundation with best quality local sand(F.M. 1.2) and
cement in (1:6:12) (cement : sand : khoa) proportion to achieve minimum dry
density of 90% with optimum moisture content (Modified proctor test) including
breaking and screening chips,laying and spreading in150mm layers uniformly and
compacting etc. all complete and accepted by the Engineer.
02.13 Earth filling in foundation trenches and plinth in 150 mm layer with earth available cum Tk. 114.00
within 90 m of the building site to achive minimum dry density of 90% with
optimum moisture content (Modified proctor test) including carrying watering,
leveling, dressing and compacting to a specified percentage each layer up to finished
level etc. all complete and accepted by the Engineer.
02.14 Clearing and disposing of excavated earth from the construction site by truck or cum Tk. 457.00
any other means to a place within 30 km radius of the city or town area including
loading, unloading at both ends, leveling and dressing the carried earth etc. complete
accepted by the Engineer.
02.15 Earth filling in foundation trenches and plinth in 150 mm layers with carted earth
carried by truck or any other means loading and unloading at both ends including
leveling, watering and compacting to achive minimum dry density of 90% with
optimum moisture content (modified proctor test) including local carriage each layer
up to finished level including cost of water and test (carried from beyond 300 m) etc.
all complete and accepted by the Engineer.
02.15.3 For Rajshahi / Barishal / Khulna metropolitan area cum Tk. 329.00
02.15.4 For other than Dhaka, Ctg., Sylhet, Rajshahi, Barishal, Khulna metropolitan area and cum Tk. 291.00
N'ganj district
02.16.1.2 By Dredging including necessary systems there off cum Tk. 265.00
02.16.4 For other than Dhaka, Ctg., Sylhet, Rajshahi, Barishal, Khulna metropolitan area and
N'ganj district
02.17 Mechanical compaction of earth beyond plinth area, required for pre-approved cum Tk. 364.00
specific engineering purpose in 150mm layers including leveling, watering and
consolidation each layer with chain dozer, grader, roller etc. to achieve minimum dry
density of 90% with optimum moisture content (modified proctor test) up to finished
level all complete and accepted by the engineer subject to submission of the method
statement.
03.1 One layer of brick flat soling in foundation or in floor with first class or picked sqm. Tk. 355.00
jhama bricks including preparation of bed and filling the interstices with local sand,
leveling etc. complete and accepted by the Engineer.
03.2 One layer of Herring bone bond (HBB) brick soling in foundation or in floor with sqm. Tk. 562.00
first class or picked jhama bricks including preparation of bed and filling the
interstices with local sand, leveling including the supply of water,other charges, costs
of tools and plants etc. all complete and accepted by the Engineer.
03.3 Brick on end edging including preparation of bed and filling the interstices with local rm. Tk. 88.00
sand, leveling, maintaining alignment grid etc. all complete and accepted by the
Engineer.
03.4 Mass concrete (1:3:6) in foundation or floor with cement, sand (F.M. 1.2) and
picked jhama chips including breaking chips, screening, mixing, laying, compacting
to levels and curing for at least 7 days including the supply of water, electricity and
other charges and costs of tools and plants etc. all complete and accepted by the
Engineer. (Cement: CEM-II/A-M)
03.4.1 Mass concrete in foundation (1:3:6) with cement, brick chips and sand of F.M. 1.2 cum Tk. 6,319.00
03.4.2 Mass concrete in floor (1:3:6) with cement brick chips and sand of F.M. 1.2 cum Tk. 6,241.00
03.5 Mass concrete (1:2:4) in foundation or floor with cement, sand (F.M. 1.2) and
picked jhama chips including breaking chips, screening, mixing, laying, compacting
to levels and curing for at least 7 days including the supply of water, electricity and
other charges and costs of tools and plants etc. all complete and accepted by the
Engineer. (Cement: CEM-II/A-M)
03.5.1 Mass concrete in foundation (1:2:4) with brick chips and local sand of F.M. 1.2 cum Tk. 7,481.00
03.5.2 Mass concrete in floor (1:2:4) with brick chips and local sand of F.M. 1.2 cum Tk. 7,403.00
03.6 Damp proof course (DPC) (1:1.5:3) in cement concrete with cement, sand (F.M.
1.2) and picked jhama or stone chips including breaking chips, screening, centering,
shuttering, casting, curing and finished with a coat of bitumen including the supply of
water, electricity and other charges and costs of tools and plants etc. all complete
and accepted by the Engineer. (Cement: CEM-II/A-M)
03.6.1 75 mm or 3" thick damp proof course (1:1.5:3) with brick chips and 50% Sylhet sqm. Tk. 1,002.00
sand (F.M. 2.2) and 50% local sand (F.M. 1.2)
03.6.2 75 mm or 3" thick damp proof course (1:1.5:3) with Sylhet sand (F.M. 2.2) and sqm. Tk. 1,174.00
stone chips.
03.6.3 150 mm or 6" thick damp proof course (1:1.5:3) with Sylhet sand (F.M. 2.2) stone cum Tk. 12,711.00
chips and water-proofing admixture/agent approved by the Engineer.
03.7 Supplying and laying of single layer polythene sheet weighing one kilogram per 6.5 sqm. Tk. 34.00
square meter in floor or any where below cement concrete complete in all respect
and accepted by the Engineer.
04.1 Brick works with first class bricks in cement sand (F.M. of sand 1.2) mortar (1:6) cum Tk. 5,327.00
in foundation and plinth, filling the joints/interstices fully with mortar, racking out the
joints, cleaning and soaking the bricks at least for 24 hours before use and curing at
least for 7 days etc. all complete including cost of water, electricity and other charges
and accepted by the Engineer. (Cement: CEM-II/A-M)
04.2 Brick works of width one brick or one and a half brick length with first class cum Tk. 5,637.00
bricks in cement sand (F.M. 1.2) mortar (1:6) in superstructure including raking
out joints, filling the interstices with mortar, cleaning and soaking the bricks at least
for 24 hours before use and washing of sand, necessary scaffolding, curing at least
for 7 days etc. all complete (measurement to given as 250 mm width for one brick
length and 375 mm for one brick and a half brick length) and accepted by the
Engineer.(Cement: CEM-II/A-M)In ground floor
04.3 Brick works with first class bricks in cement sand (F.M. 1.2) mortar (1:4) in cum Tk. 6,013.00
exterior walls including filling the interstices with mortar, raking out joints, cleaning
and socking the bricks at least for 24 hours before use and washing of sand,
necessary scaffolding, curing at least for 7 days etc. all complete including cost of
water, electricity and other charges (measurement to given as 250 mm width for one
brick length and 375 mm for one brick and a half brick length) accepted by the
Engineer. (Cement: CEM-II/A-M). In ground floor
04.4 Exposed brick works (for exterior wall without outside plaster) with special cum Tk. 6,984.00
quality sorted out first class bricks, very carefully laid in cement sand (F.M. 1.2)
mortar (1:4)) in superstructure with uniform width and depth joints, true to vertical
and horizontal lines including raking out joints scaffolding, soaking the bricks at least
for 24 hours before use, washing and screening of sand. Curing at least for 7 days
and high class flush pointing with cement sand (F.M. 1.2) mortar (1:1) including cost
of water, electricity and other charges etc all complete and accepted by the
Engineer. (Cement: CEM-II/A-M). In ground floor
04.5 Exposed brick works (for exterior wall without outside plaster) with automatic cum Tk. 6,984.00
machine made first class bricks, very carefully laid in cement sand (F.M. 1.2)
mortar (1:4)) in superstructure with uniform width and depth joints, true to vertical
and horizontal lines including raking out joints scaffolding, soaking the bricks at least
for 24 hours before use, washing and screening of sand. Curing at least for 7 days
and high class flush pointing with cement sand (F.M. 1.2) mortar (1:1) including cost
of water, electricity and other charges etc all complete and accepted by the
Engineer. (Cement: CEM-II/A-M). In ground floor
04.6 Brick works with 10 holes machine made bricks of approved size (9.5" x 4.5" x cum Tk. 10,950.00
2.75") having uniform colour carefully laid in cement sand (F.M. 1.2) mortar (1:4) in
superstructure with uniform width and depth joints, true to vertical and horizontal
lines including raking out joints, filling the interstices with mortar, cleaning and
soaking bricks at least for 24 hours before use and washing and screening of sand,
necessary scaffolding, curing at least for 7 days and pointing with cement sand (F.M.
1.2) mortar (1:2) including cost of water, electricity and other charges etc. complete
and accepted by the Engineer. (Cement: CEM-II/A-M) In ground floor
PWD SoR 2014 for Civil Works 69
04.7 Brick work with 9.5" x 4.5" x 2.75" size machine made solid klinker facing cum Tk. 8,874.00
bricks having uniform colour carefully laid in cement sand (F.M. 1.2) mortar (1:4) in
superstructure with uniform width and depth joints, true to vertical and horizontal
lines including raking out joints, filling the interstices with mortar, cleaning and
soaking bricks at least for 24 hours before use and washing and screening of sand,
necessary scaffolding, curing at least for 7 days and pointing with cement sand (F.M.
1.2) mortar (1:2) including cost of water, electricity and other charges etc. complete
and accepted by the Engineer.(Cement: CEM-II/A-M)In ground floor
04.8 Brick works with 9.5" x 4.5" x 2.75" size 10 hole machine made Rock-face or cum Tk. 8,757.00
textured klinker facing bricks having uniform colour carefully laid in cement sand
(F.M. 1.2) mortar (1:4) in superstructure with uniform width and depth joints, true to
vertical and horizontal lines including raking out joints, filling the interstices with
mortar, cleaning and soaking bricks at least for 24 hours before use and washing
and screening of sand, necessary scaffolding, curing at least for 7 days and pointing
with cement sand (F.M. 1.2) mortar (1:2) including cost of water, electricity and other
charges etc. all complete and accepted by the Engineer. (Cement: CEM-II/A-M)
In ground floor
04.9 Brick works with 9.5" x 4.5" x 2.75" size 3 hole machine made reinforced cum Tk. 12,296.00
klinker facing bricks having uniform colour carefully laid in cement sand (F.M.1.2)
mortar (1:4) in superstructure with uniform width and depth joints, true to vertical
and horizontal lines including raking out joints, filling the interstices with mortar,
cleaning and soaking bricks at least for 24 hours before use and washing and
screening of sand, necessary scaffolding, curing at least for 7 days and pointing with
cement sand (F.M. 1.2) mortar (1:2) including cost of water, electricity and other
charges etc. all complete and accepted by the Engineer. (Cement: CEM-II/A-M) In
ground floor
04.10 Extra cost shall be incorporated in the estimate for each additional floor for brick
works (item No.- 4.2 to 4.9)
04.10.1 Add for each additional floor up to 5th floor cum Tk. 130.00
04.10.2 Add for each additional floor from 6th floor to 9th floor cum Tk. 182.00
04.10.3 Add for each additional floor for 10th floor and above cum Tk. 208.00
04.11 Extra cost for brick-work for each additional meter (or part of meter) free cum Tk. 136.00
height of brick wall beyond 4 m from the respective floor in auditorium, go-down,
overhead water tank etc. as description of the item No. in 16, 17, 18 and 19 including
cost of water, electricity and other charges etc. all complete and accepted by the
Engineer. (Extra cost shall be incorporated in the estimate only when both sides of
wall is uninterruptedly free beyond 4.00 meter)
04.12 Providing brick works for 200 x 100 mm facing in superstructure with 200 x 100 sqm. Tk. 1,586.00
x 50 mm machine made klinker hard pressed facing bricks of approved quality in
cement sand (F.M. 1.2) mortar (1:4), including racking out joints, cutting the bricks to
required size wherever necessary including high class recessed pointing, cleaning
and soaking the bricks at least for 24 hours before use and washing and screening of
sand, necessary scaffolding, curing at least for 7 days for all floors up to 4th floor
including cost of water, electricity and other charges etc. all complete and accepted
by the Engineer.(100 x 200 mm face should be placed for facing).(Cement: CEM-
II/A-M)In ground floor
PWD SoR 2014 for Civil Works 70
04.13 Providing brick works in facing for 200 x 50 mm in superstructure with 200 x 50 sqm. Tk. 2,091.00
x 50 mm machine made hard pressed klinker facing red or Maroon strips of
approved quality pressed with 20 mm thick cement sand (F.M.1.2) mortar (1:4), 10
mm thick cement mortar in adjacent sites including racking out joints and cutting the
bricks to required sizes wherever necessary with high class recessed pointing,
cleaning and soaking the bricks for at least 24 hours before use and washing of sand
necessary scaffolding, curing at least for 7 days for all floors up to 4th floor including
cost of water, electricity and other charges etc. all complete and accepted by the
Engineer. (Cement: CEM-II/A-M). In ground floor
04.14 Providing brick works for 200 x 62 mm facing in superstructure with 200 x 62 x sqm. Tk. 2,065.00
16.51 mm machine made hard pressed klinker facing RED strips of approved
quality with 20 mm thick cement sand (F.M.1.2) mortar (1:3) in adjacent side wall,
column, drop wall etc. and racking out joints, cutting the bricks to required sizes
wherever necessary with high class recessed pointing, cleaning and soaking the
bricks at least for 24 hours before use washing and screening of sand and necessary
scaffoldings, curing at least 7 days including cost of water, electricity and other
charges etc. all complete and accepted by the Engineer. (Cement: CEM-II/A-M) In
ground floor
04.15 125 mm brick work with first class bricks in cement sand (F.M. 1.2) mortar (1:6) sqm. Tk. 798.00
and making bond with connected walls including necessary scaffolding, raking out
joints, cleaning and soaking the bricks for at least 24 hours before use and washing
of sand curing at least for 7 days in all floors including cost of water, electricity and
other charges etc. all complete and accepted by the Engineer. (Cement: CEM-II/A-
M) In ground floor
04.16 125 mm brick works with first class bricks in cement sand (F.M. 1.2) mortar (1:4) sqm. Tk. 837.00
and making bond with connected walls including necessary scaffolding, raking out
joints, cleaning and soaking the bricks for at least 24 hours before use and washing
of sand curing at least for 7 days in all floors including cost of water, electricity and
other charges etc. all complete and accepted by the Engineer. (Cement: CEM-II/A-
M) In ground floor
04.17 Exposed 125 mm thick pointing extra ordinary ornamental brick work with sqm. Tk. 1,016.00
sorted out first class bricks in cement sand (F.M. 1.2) mortar (1:4) and making
bond with connected walls including necessary scaffolding, raking out joints, cleaning
and soaking the bricks for at least 24 hours before use and washing of sand curing at
least for 7 days in all floors including cost of water, electricity and other charges etc.
all complete and accepted by the Engineer.(Cement: CEM-II/A-M)In ground floor
04.18 Exposed 125 mm thick pointing extra ordinary ornamental brick work with sqm. Tk. 1,030.00
automatic machine made first class bricks in cement sand (F.M. 1.2) mortar (1:4)
and making bond with connected walls including necessary scaffolding, raking out
joints, cleaning and soaking the bricks for at least 24 hours before use and washing
of sand curing at least for 7 days in all floors including cost of water, electricity and
other charges etc. all complete and accepted by the Engineer. (Cement: CEM-II/A-
M) In ground floor
PWD SoR 2014 for Civil Works 71
04.19 Providing 125 mm thick (Partition walls) brick work in superstructure brick work sqm. Tk. 1,499.00
(1:4) in cement sand (F.M. 1.2) mortar with 10 hole machine made ceramic
bricks of approved size having uniform colour, carefully laid in cement mortar and
depth joints true to vertical and horizontal lines including. racking out joints, filling the
interstices with same mortar, making bond with connected walls, cleaning, soaking
brick at least 24 hours and washing of sand, curing 7 days in all floors, including cost
of water, electricity and other charges accepted by the Engineer. (Cement: CEM-II/A-
M) In ground floor
04.20 Fancy screen work with different size hollow machine made design blocks with
uniform colour, carefully laid in coloured cement sand (F.M. 1.2) mortar (1:3) in all
floors in wall with uniform mortar joints, true to vertical and horizontal line including
racking out joints, cleaning and soaking the blocks for minimum 24 hours before use
including washing and screening of sand, scaffolding, curing etc. complete in all
respect including supply of all necessary materials including cost of water, electricity
and other charges accepted by the Engineer. (Cement: CEM-II/A-M)
04.20.1 With design block No. 3 (MCW) size: 4" x 4" x 4" or equivalent volume & design sqm. Tk. 4,102.00
In ground floor
04.20.2 With design block No. 1 (MCW) size: 5.5" x 5.5" x 4" or equivalent volume & design sqm. Tk. 2,403.00
In ground floor
04.20.3 With design block No. 20 (MCW) size: 6" x 6" x 4" or equivalent volume and design sqm. Tk. 2,323.00
In ground floor
04.21 Extra cost shall be incorporated in the estimate for each additional floor for brick
and screen block works (item No.- 4.12 to 4.20)
04.21.1 Add for each additional floor up to 5th floor sqm. Tk. 24.00
04.21.2 Add for each additional floor from 6th floor to 9th floor sqm. Tk. 32.00
04.21.3 Add for each additional floor for 10th floor and above sqm. Tk. 40.00
04.22 Klinker paving brick works in floor or pavement with machine made pressed bricks
of approved quality in cement sand (F.M. 1.2) mortar (1:4) on minimum 12 mm thick
cement sand (F.M. 1.2) mortar (1:4) including raking out joints, cutting the bricks to
required size soaking the same 24 hours before use wherever necessary including
high class flush pointing in cement mortar (1:2), cleaning, curing at least for 7 days
etc. including washing and screening of sand, cost of water, electricity and other
charges complete and standard practice accepted by the Engineer.(Cement: CEM-
II/A-M)
04.22.1 100 mm thick brick on edge pavement with 200 x 100 x 50 mm size klinker facing sqm. Tk. 2,599.00
bricks.
04.22.2 50 mm thick flat brick pavement with 200 x 100 x 50 mm klinker paving bricks in 1:4 sqm. Tk. 1,523.00
cement sand mortar having 200 x 100 mm face at top.
04.22.3 50 mm thick brick pavement with 200 x 50 x 50 mm klinker facing bricks. sqm. Tk. 2,013.00
PWD SoR 2014 for Civil Works 72
04.23 125 mm thick brick pavement or flooring with first class brick on edge in cement sqm. Tk. 943.00
sand (F.M. 1.2) mortar (1:4) on minimum 12 mm thick cement sand (F.M. 1.2) mortar
(1:4) including cutting the bricks as per requirement, cleaning and racking out joints,
finishing with flush pointing with cement sand (F.M. 1.2) mortar (1:2) and curing for at
least 7 days etc. including cost of water, washing and screening of sand (F.M. 1.2),
electricity and other charges complete and standard practice accepted by the
Engineer. (Cement: CEM-II/A-M)
04.24 125 mm thick brick pavement/flooring with 10 hole machine made ceramic sqm. Tk. 1,578.00
bricks in cement sand (F.M. 1.2) mortar (1:4) on minimum 12 mm thick cement
sand (F.M. 1.2) mortar (1:4) including cutting the bricks as per requirement, cleaning
and racking out joints, finishing with flush pointing with cement sand (F.M. 1.2)
mortar (1:2) and curing for at least 7 days etc. including cost of water, washing and
screening of sand (F.M. 1.2), electricity and other charges etc. all complete and
accepted by the Engineer. (Cement: CEM-II/A-M)
04.25 75 mm thick cement concrete (1:3:6) with cement in flooring best quality coarse sqm. Tk. 526.00
sand and 19 mm down graded picked chips including breaking chips, screening,
mixing, laying, compacting, washing and screening of sand of F.M 1.2 and curing at
least for 7 days etc. including cost of water, electricity and other charges etc. all
complete and accepted by the Engineer. Cement: CEM-II/A-M)
04.26 25 mm thick artificial patent stone (1:2:4) flooring with cement, best quality coarse sqm. Tk. 332.00
sand (50% quantity of Sylhet sand or coarse sand of equivalent F.M. 2.2 and 50%
best local sand of FM 1.2) and 12 mm down well graded brick chips including
breaking chips, screening, laying the concrete in alternate panels, compacting and
finishing the top with neat cement and curing at least 7 days in all floors including
cost of water, electricity and other charges etc. all complete and accepted by the
Engineer.(Cement: CEM-II/A-M)In ground floor
04.27 38 mm thick artificial patent stone (1:2:4) flooring with cement, best quality coarse sqm. Tk. 423.00
sand (50% quantity of Sylhet sand or coarse sand of equivalent F.M. 2.2 and 50%
best local sand of FM 1.2) and 12 mm down well graded brick chips including
breaking chips, screening, laying the concrete in alternate panels, compacting and
finishing the top with neat cement and curing at least 7 days in all floors including
cost of water, electricity and other charges etc. all complete and accepted by the
Engineer. (Cement: CEM-II/A-M) In ground floor
04.28 25 mm thick artificial patent stone (1:2:4) flooring with cement, best quality coarse sqm. Tk. 390.00
sand (50% quantity of Sylhet sand or coarse sand of equivalent F.M. 2.2 and 50%
best local sand of FM 1.2) and 12 mm down well graded stone chips, laying the
concrete in alternate panels, compacting and finishing the top with neat cement and
curing at least 7 days in all floors including cost of water, electricity and other
charges etc. all complete and accepted by the Engineer. (Cement: CEM-II/A-M)
In ground floor
04.29 38 mm thick artificial patent stone (1:2:4) flooring with cement, best quality coarse sqm. Tk. 510.00
sand (50% quantity of Sylhet sand or coarse sand of equivalent F.M. 2.2 and 50%
best local sand of FM 1.2) and 12 mm down well graded stone chips, laying the
concrete in alternate panels, compacting and finishing the top with neat cement and
curing at least 7 days in all floors including cost of water, electricity and other
charges etc. all complete and accepted by the Engineer.
Cement: (CEM-II/A-M) In ground floor
PWD SoR 2014 for Civil Works 73
04.30 25 mm thick artificial patent stone (1:1.5:3) flooring with cement, best quality sqm. Tk. 409.00
coarse sand (50% quantity of Sylhet sand or coarse sand of equivalent F.M. 2.2 and
50% best local sand of FM 1.2) and 12 mm down well graded stone chips, laying
the concrete in alternate panels, compacting and finishing the top with neat cement
and curing at least 7 days in all floors including cost of water, electricity and other
charges etc. all complete and accepted by the Engineer. (Cement: CEM-II/A-M) In
ground floor
04.31 38 mm thick artificial patent stone (1:1.5:3) flooring with cement, best quality sqm. Tk. 539.00
coarse sand (50% quantity of Sylhet sand or coarse sand of equivalent F.M. 2.2 and
50% best local sand of FM 1.2) and 12 mm down well graded stone chips, laying
the concrete in alternate panels, compacting and finishing the top with neat cement
and curing at least 7 days in all floors including cost of water, electricity and other
charges etc. all complete and accepted by the Engineer.(Cement: CEM-II/A-M)In
ground floor
04.32 Extra cost shall be incorporated in the estimate for each additional floor for patent
stone works.
04.32.1 Add for each additional floor up to 5th floor sqm. Tk. 24.00
04.32.2 Add for each additional floor from 6th floor to 9th floor sqm. Tk. 32.00
04.32.3 Add for each additional floor for 10th floor and above sqm. Tk. 40.00
05.1 10 mm thick finished and 12 mm laying thickness situ mosaic work on floor with
one part of 10 mm machine crushed well graded dust free and properly washed
marble chips and one part of mixture containing white cement / grey cement
including preparation of mix. and laying the same over minimum 25 mm thick artificial
patent stone flooring with brick chips (1:2:4) including making suitable panel,
compacting, curing at least for 7 days, cutting with pumic stone (No. 40, No. 80,
No.120)/cutting with mosaic machine and finishing with Minar stone and spreading
oxalic acid including breaking brick chips, screening, washing mosaic chips and
supply of all necessary materials and water, electricity and other charges in all
respect accepted by the Engineer. (Cement: CEM-II/A-M)
05.1.1 With Indian chips and glass strip using 100% white cement. sqm. Tk. 1,500.00
In Ground Floor
05.1.2 With Indian chips and glass strip using 100% grey cement. sqm. Tk. 1,233.00
In ground floor
05.1.3 With Pakistani chips and glass strip using 100% white cement. sqm. Tk. 1,533.00
In ground floor
05.1.4 With Indian chips and without glass strip using 100% white cement. sqm. Tk. 1,315.00
In ground floor
05.1.5 With Indian chips and without glass strip using 100% grey cement.In ground floor sqm. Tk. 1,109.00
05.1.6 With Pakistani chips and without glass strip using 100% white cement. sqm. Tk. 1,347.00
In ground floor
05.2 12 mm thick finished and laying thickness 14.5 mm cast in situ mosaic work on
floor with one part of 10 mm machine crushed well graded dust free and properly
washed marble chips and one part of mixture containing 100% white cement
including preparation of mix and laying the same over minimum 25 mm thick artificial
patent stone flooring with brick-chips (1:2:4) including making suitable panel,
compacting, curing at least for 7 days, cutting with pumic stone (No. 40, No. 80, No.
120)/ mosaic cutting machine and finishing with Minar stone including breaking brick
chips screening, spreading oxalic acid, washing mosaic chips and supply of all
necessary materials and water, electricity and other charges in all respect accepted
by the Engineer. (Cement: CEM-II/A-M)
05.2.1 With Indian chips and glass strip. sqm. Tk. 1,582.00
In ground floor
05.2.2 With Pakistani chips and glass strip. sqm. Tk. 1,618.00
In ground floor
05.2.3 With Indian chips and without glass strip. sqm. Tk. 1,396.00
In ground floor
05.2.4 With Pakistani chips and without glass strip. sqm. Tk. 1,432.00
In ground floor
PWD SoR 2014 for Civil Works 75
05.3 10 mm thick finished and laying thickness 12.5 mm silver grey situ mosaic work
on floor with one part of 10 mm machine crushed well graded, dust free and
properly washed marble chips and one part of mixture containing white cement and
grey cement in proportion (1:1) including preparation of mix and laying the same
over minimum 25 mm thick artificial patent stone flooring with brick-chips (1:2:4)
including making suitable panel, compacting, curing at least for 7 days, cutting with
pumic stone (No. 40, No. 80, No. 120) and finishing with Minar stone including
breaking brick chips, screening, washing mosaic chips and supply of all necessary
materials including and water, electricity and other charges in all respect accepted by
the Engineer. (Cement: CEM-II/A-M)
05.3.1 With Indian chips and with glass strip. sqm. Tk. 1,369.00
In ground floor
05.3.2 With Pakistani chips and with glass strip. sqm. Tk. 1,402.00
In ground floor
05.3.3 With Indian chips and without glass strip. sqm. Tk. 1,184.00
In ground floor
05.3.4 With Pakistani chips and without glass strip.In ground floor sqm. Tk. 1,216.00
05.4 12 mm thick finished and laying thickness 14.5 mm silver grey cast in situ mosaic
work on floor with one part of 10 mm machine crushed well graded dust free and
properly washed marble chips and one part of mixture containing white cement dust
free and properly washed marble chips and one part of mixture containing white
cement and grey with cement in proportion (1:1) including. preparation of mix and
laying the same over minimum 25 mm thick artificial patent stone flooring with brick-
chips (1:2:4) including making suitable panels, compacting, curing at least for 7 days,
cutting with pumic stone (No. 40. No. 80, No. 120) and finishing with Minar stone
including breaking brick chips, screening, washing mosaic chips and supply of all
necessary materials and water, electricity and other charges in all respect accepted
by the Engineer. (Cement: CEM-II/A-M)
05.4.1 With Indian chips and with glass strip. sqm. Tk. 1,435.00
In ground floor
05.4.2 With Pakistani chips and with glass strip. sqm. Tk. 1,471.00
In ground floor
05.4.3 With Indian chips and without glass strip. sqm. Tk. 1,250.00
In ground floor
05.4.4 With Pakistani chips and without glass strip. sqm. Tk. 1,286.00
In ground floor
05.5 10 mm thick finished and laying thickness 12.5 mm situ mosaic work on wall with
one part of 10 mm machine crushed well graded dust free and properly washed
marble chips and one part of mixture containing 100% white cement including
preparation of mix and laying the same on 12 mm thick cement plaster (1:4) to wall,
compacting, curing at least for 7 days, cutting with pumic stone (No. 40, No. 80, No.
120) including finishing the corners and edges and also finishing with Minar stone
and supplying all necessary materials in and water, electricity and other charges in
all respect accepted by the Engineer. (Cement: CEM-II/A-M)
PWD SoR 2014 for Civil Works 76
05.6 10 mm thick finished and laying thickness silver grey situ mosaic work on wall
with one part of 10 mm machine crushed well graded, dust free and properly washed
marble chips and one part of mixture containing white cement and grey cement in
proportion (1:1) including preparation of mix. and laying the same on 12 mm thick
cement plaster (1:4) to wall, compacting, curing at least for 7 days, cutting with pumic
stone (No. 40, No. 80, No 120) including finishing the corners and edges and also
finishing with Minar stone and supplying all necessary materials in and water,
electricity and other charges in all respect accepted by the Engineer. (Cement: CEM-
II/A-M)
05.6.3 With Indian chips using 100% grey cement. sqm. Tk. 1,199.00
In ground floor
05.7 10 mm thick finished laid in 12.5 mm thickness coloured situ mosaic work in floor
with one part of 10 mm machine crushed well graded, dust free and properly washed
marble chips and one part of mixture containing white and grey cement in proportion
(1:9) and necessary quantity of approved colouring materials including preparation of
mix and laying the same over min 25 mm thick artificial patent stone flooring with
brick-chips (1:2:4) including making suitable panel, compacting, curing at least for 7
days, cutting with pumic stone (No. 40, No. 80, No. 120) and finishing with Minar
stone including breaking brick chips, screening, washing mosaic chips and supply of
all necessary materials in all respects and water, electricity and other charges in all
respect accepted by the Engineer. (Cement: CEM-II/A-M)
05.7.1 With Indian chips and with glass strip. sqm. Tk. 1,557.00
In ground floor
05.7.2 With Pakistani chips and with glass strip. sqm. Tk. 1,590.00
In ground floor
05.7.3 With Indian chips and without glass strip. sqm. Tk. 1,372.00
In ground floor
05.7.4 With Pakistani chips and without glass strip. sqm. Tk. 1,273.00
In ground floor
PWD SoR 2014 for Civil Works 77
05.8 12 mm thick finished and laying thickness 14 mm coloured situ mosaic on floor
with one part of 10 mm machine crushed well graded, dust free and properly washed
marble chips and one part of mixture containing white cement and grey cement in
proportion (9:1) and necessary quantity of approved colourings materials including
preparation of mix and laying the same over minimum 25 mm thick artificial patent
stone flooring with brick-chips (1:2:4) including making suitable panel, compacting,
curing at least for 7 days, cutting with pumic stone (No. 40, No. 80, No. 120) and
finishing with Minar stone including breaking brick chips, screening, washing mosaic
chips and supply of all necessary materials in all respects and water, electricity and
other charges in all respect accepted by the Engineer. (Cement: CEM-II/A-M)
05.8.1 With Indian chips and with glass strip. sqm. Tk. 1,639.00
In ground floor
05.8.2 With Pakistani chips and with glass strip. sqm. Tk. 1,675.00
In ground floor
05.8.3 With Indian chips and without glass strip. sqm. Tk. 1,453.00
In ground floor
05.8.4 With Pakistani chips and without glass strip. sqm. Tk. 1,489.00
In ground floor
05.9 10 mm thick finished and laying thickness 12.5 mm coloured situ mosaic on walls
with one part of 10 mm machine crushed well graded, dust free and properly washed
marble chips and one part of mixture containing white cement and grey cement in
proportion (9:1) and necessary quantity of approved colouring materials including
preparation of mix and laying the same on 12 mm thick cement sand (F.M. 1.2)
plaster (1:4) to walks including compacting, curing at least for 7 days, cutting with
pumic stone (No. 40, No. 80, No. 120) including finishing the corners and edges and
also finishing with Minar stone and supply of all necessary materials etc. and water,
electricity and other charges complete in all respect accepted by the Engineer.
(Cement: CEM-II/A-M)
05.10 200 x 200 x 20 mm mosaic terrazzo tiles flooring having 10 mm thick finished
mosaic top with one part of 10 mm machine crushed well graded dust free and
properly washed marble chips and one part of mixture containing white cement and
grey cement in 9:1 proportion in/c supply of all necessary materials etc. and water,
electricity and other charges complete in all respect accepted by the Engineer and
preparation of mix machine pressed on 12 mm thick cement sand (F.M. 1.2 and 2.5
by 50% each) mortar (1:2) base including preparing the base; finally, setting the
tiles on 40 mm thick cement sand (F.M.1.2 and 2.5 by 50% each) mortar,
compacting, cutting with pumic stone (No. 40, No. 80, No. 120) and finishing the
corners and edges and also finishing with minar stone including screening, washing
mosaic chips and supply of all necessary materials etc. and water, electricity and
other charges complete in all respect accepted by the Engineer.(Cement: CEM-II/A-
M)
05.10.1 200 x 200 x 20 mm (finished) mosaic terrazzo tiles flooring with Indian chips. sqm. Tk. 1,458.00
In ground floor
PWD SoR 2014 for Civil Works 78
05.10.2 200 x 200 x 20 mm (finished) mosaic terrazzo tiles flooring with Pakistani chips. sqm. Tk. 1,489.00
In ground floor
05.11 Extra cost shall be incorporated in the estimate for mosaic and terrazzo tiles work
above ground floor (item No.- 5.1 to 5.10).
05.11.1 Add for each additional floor up to 5 th floor sqm. Tk. 8.00
05.11.2 Add for each additional floor for 6th to 9th floor sqm. Tk. 16.00
05.11.3 Add for each additional floor for 10th floor and above sqm. Tk. 24.00
06.1 Marble stone flooring with Indian black/ white marble stone of approved quality,
texture and size over 25 mm thick cement sand (F.M. 1.2) mortar (1:2) including.
placing cement slurry below the stone, cutting the marble stone to desired size,
grinding and finishing the edges, setting in position in proper level filling the gaps
with white cement and colouring pigments including supplying all necessary
equipments/materials and finishing the top by pumic stone and necessary auxiliary
materials and water, electricity and other charges complete in all respect accepted
by the Engineer.(Cement: CEM-II/A-M)
06.2 Marble stone flooring with Indian coloured/ grey marble stone of approved
quality, texture and size over 25 mm thick cement sand (F.M. 1.2) mortar (1:2)
including. placing cement slurry below the stone, cutting the marble stone to desired
size, grinding and finishing the edges, setting in position in proper level filling the
gaps with white cement and colouring pigments including supplying all necessary
equipments/materials and finishing the top by pumic stone and necessary auxiliary
materials and water, electricity and other charges complete in all respect accepted
by the Engineer. (Cement: CEM-II/A-M)
06.3 Supplying and setting Indian marble stone of approved quality, textured and size
on walls over 12 mm thick cement sand (F.M. 1.2) mortar (1:2) including cutting and
grinding the marble stone slab/tile setting in position keeping horizontal and vertical
alignment correct, filling the joints with white cement, cutting and grinding the top
surface, finishing etc including water, electricity and other charges complete in all
respect accepted by the Engineer. (Cement: CEM-II/A-M)
06.3.1 12 mm thick white/ black Marble stone walling sqm. Tk. 5,213.00
In ground floor
06.3.2 12 mm thick grey or coloured Marble stone walling sqm. Tk. 5,601.00
In ground floor
06.4 Marble stone flooring with 18mm thick Italian coloured/ grey marble stone of sqm. Tk. 8,281.00
approved quality, texture and size over 25 mm thick cement sand (F.M. 1.2) mortar
(1:2) including. placing cement slurry below the stone, cutting the marble stone to
desired size, grinding and finishing the edges, setting in position in proper level filling
the gaps with white cement and colouring pigments including supplying all necessary
equipments/materials and finishing the top by pumic stone and necessary auxiliary
materials and water, electricity and other charges complete in all respect accepted
by the Engineer.(Cement: CEM-II/A-M)In ground floor
PWD SoR 2014 for Civil Works 80
06.5 Labour Cost for making moulding in marble stone as per Architectural drawing
including cutting, grinding, finishing, supplying necessary equipment etc. complete in
all respect as per direction of the Engineer in Charge. (Cement: CEM-II/A-M)
06.6 Supplying, fitting and fixing country made glazed wall tiles ,irrespective of color
&/or design, with on 20 mm thick cement sand (F.M. 1.2) mortar (1:3) base and
raking out the joints with repective joint filler & binder including cutting, laying and
hire charge of machine and finishing with care etc. including water, electricity and
other charges complete all respect accepted by the Engineer.
(Cement: CEM-II/A-M). In ground floor
06.6.1 Wall tiles less than , equal or equivalent to 250mmx330mm in sizes sqm. Tk. 1,230.00
06.6.2 Wall tiles more than 250x330 & less than 250x400 in sizes or equivalent sqm. Tk. 1,339.00
06.6.3 Wall tiles more 250x400mm in sizes or equivalent sqm. Tk. 1,624.00
06.7 Supplying, fitting and fixing country made GP(Gress Porcellanato) - glazed
homogeneous floor tiles irrespective of color &/or design, with cement sand
(F.M. 1.2) mortar (1:4) base and raking out the joints with white cement including
cutting and laying the tiles in proper way and finishing with care etc. all complete and
accepted by the Engineer.(Cement: CEM-II/A-M). In ground floor
06.8 Supplying, fitting and fixing countrymade unglazed homogeneous floor tiles
irrespective of color &/or design, with cement sand (F.M. 1.2) mortar (1:4) base
and raking out the joints with white cement including cutting and laying the tiles in
proper way and finishing with care etc. all complete and accepted by the Engineer.
(Cement: CEM-II/A-M) In ground floor
06.9 Supplying, fitting and fixing countr made mirror polished homogeneous floor tiles
irrespective of color &/or design, with cement sand (F.M. 1.2) mortar (1:4) base
and raking out the joints with white cement including cutting and laying the tiles in
proper way and finishing with care etc. all complete and accepted by the Engineer.
(Cement: CEM-II/A-M) In ground floor
06.9.1 GP (mirror polished) 300 x 300 mm floor tiles sqm. Tk. 1,645.00
06.9.2 GP (mirror polished) 400 x 400 mm floor tiles sqm. Tk. 1,780.00
06.9.3 GP (mirror polished) 600 x 600 mm floor tiles sqm. Tk. 2,038.00
PWD SoR 2014 for Civil Works 81
06.10 Supplying, fitting and fixing country made GP homogeneous stair tiles irrespective sqm. Tk. 1,536.00
of color &/or design, with cement sand (F.M. 1.2) mortar (1:4) base and raking out
the joints with white cement including cutting and laying the tiles in proper way and
finishing with care etc. all complete and accepted by the Engineer. (Cement: CEM-
II/A-M) In ground floor
06.11 Supplying, fitting and fixing country made floor tiles irrespective of color &/or
design,with adhesives in full thickness of tiles ,filler/tiles grout in/c cutting, shaping,
placing in proper level etc. all complete as direction of the Engineer in charge. In
ground floor
06.11.1 GP glazed homogenous floor tiles (400 x 400 mm) sqm. Tk. 1,360.00
06.11.2 GP glazed homogenous floor tiles (300 x 300 mm) sqm. Tk. 1,224.00
06.11.3 GP un-glazed homogenous floor tiles (400 x 400 mm) sqm. Tk. 1,374.00
06.11.4 GP un-glazed homogenous floor tiles (300 x 300 mm) sqm. Tk. 1,279.00
06.11.5 GP Mirror Polished floor tiles (300 x 300 mm) sqm. Tk. 1,414.00
06.11.6 GP Mirror Polished floor tiles (400 x 400 mm) sqm. Tk. 1,550.00
06.11.7 GP Mirror Polished floor tiles (600 x 600 mm) sqm. Tk. 1,808.00
06.12 Extra Rate for each additional floor for Tiles and Marble Stone Works
06.12.1 Add for each addl. floor up to 5th floor sqm. Tk. 8.00
06.12.2 Add for each addl. floor for 6th floor to 9th floor sqm. Tk. 16.00
06.12.3 Add for each addl. floor for 10th floor and above sqm. Tk. 24.00
07.1 Reinforced cement concrete works using wooden shutter, with minimum
cement content relates to mix ratio 1:2:4 having minimum f 'cr = 24 Mpa, and
satisfying, specified compressive strength f’'c= 19 Mpa at 28 days on standard
cylinders as per standard practice of Code ACI/BNBC/ASTM & cement conforming to
BDS EN-197-1- CEM1, 52.5N (52.5MPa)/ ASTM-C 150 Type – I, best quality sand
[50% quantity of best local sand (F.M. 1.2) and 50% quantity of Sylhet sand or
coarse sand of equivalent F.M. 2.2] and 20 mm down well graded picked jhama brick
chips conforming ASTM C-33 including breaking chips and screening, making,
placing shutter in position and maintaining true to plumb, making shutter water-
tight properly, placing reinforcement in position; mixing in standard mixer machine
with hoper fed by standard measuring boxes, casting in forms, compacting by
vibrator machine and curing for 28 days,and removing centering-shuttering after
specified time approved; including cost of water, electricity, additional testing
charges of materials and cylinders required by engineer, other charges etc. all
complete approved and accepted by the Engineer.
(Rate is excluding the cost of reinforcement and its fabrication, placing and
binding etc)
07.1.1.2 Formwork/shuttering, prop and necessary supports etc. (wooden) sqm. Tk. 354.00
07.1.2.2 Formwork/shuttering, prop and necessary supports etc. (wooden) sqm. Tk. 413.00
07.1.3.2 Formwork/shuttering, prop and necessary supports etc. (wooden) sqm. Tk. 355.00
07.1.4 Padestals, column capitals, lift walls and walls upto Ground Floor
07.1.4.2 Formwork/shuttering, prop and necessary supports etc. (wooden) sqm. Tk. 412.00
07.1.5.2 Formwork/shuttering, prop and necessary supports etc. (wooden) sqm. Tk. 394.00
07.1.6 Tee beams, Ell beams and Rectangular beams etc upto Ground Floor
07.1.6.2 Formwork/shuttering, prop and necessary supports etc. (wooden) sqm. Tk. 485.00
07.1.7.2 Formwork/shuttering, prop and necessary supports etc. (wooden) sqm. Tk. 459.00
07.1.8 Cornice, railing, drop walls, louver, fins etc upto Ground Floor
07.1.8.2 Formwork/shuttering, prop and necessary supports etc. (wooden) sqm. Tk. 344.00
07.1.9.2 Formwork/shuttering, prop and necessary supports etc. (wooden) sqm. Tk. 395.00
07.1.10.2 Formwork/shuttering, prop and necessary supports etc. (wooden) sqm. Tk. 381.00
07.1.11.2 Formwork/shuttering, prop and necessary supports etc. (wooden) sqm. Tk. 584.00
PWD SoR 2014 for Civil Works 84
07.2 Reinforced cement concrete works using steel shutter, with minimum cement
content relates to mix ratio 1:2:4 having minimum f 'cr = 24 Mpa, and satisfying a
specified compressive strength f ’c= 19 Mpa at 28 days on standard cylinders as per
standard practice of Code ACI/BNBC/ASTM & cement conforming to BDS EN-197-1-
CEM1, 52.5N (52.5MPa) / ASTM-C 150 Type – I, best quality sand [50% quantity of
best local sand (F.M. 1.2) and 50% quantity of Sylhet sand or coarse sand of
equivalent F.M. 2.2] and 20 mm down well graded picked jhama brick chips
conforming ASTM C-33 including breaking chips and screening, making, placing
shutter in position and maintaining true to plumb, making shutter water-tight
properly, placing reinforcement in position; mixing in standard mixer machine with
hoper fed by standard measuring boxes, casting in forms, compacting by vibrator
machine and curing at least for 28 days, removing centering-shuttering after
specified time approved; including cost of water, electricity, additional testing
charges of materials and cylinders required by engineer, other charges etc. all
complete approved and accepted by the Engineer. (Rate is excluding the cost of
reinforcement and its fabrication, placing and binding etc)
07.2.1.2 Formwork/shuttering, prop and necessary supports etc. (steel) sqm. Tk. 382.00
07.2.2.2 Formwork/shuttering, prop and necessary supports etc. (steel) sqm. Tk. 391.00
07.2.3.2 Formwork/shuttering, prop and necessary supports etc. (steel) sqm. Tk. 323.00
07.2.4 Padestals, column, column capitals, lift walla and walls upto Ground Floor
07.2.4.2 Formwork/shuttering, prop and necessary supports etc. (steel) sqm. Tk. 373.00
07.2.5.2 Formwork/shuttering, prop and necessary supports etc. (steel) sqm. Tk. 380.00
07.2.6 Tee beams, Ell beams and Rectangular beams etc upto Ground Floor
07.2.6.2 Formwork/shuttering, prop and necessary supports etc. (steel) sqm. Tk. 415.00
07.2.7.2 Formwork/shuttering, prop and necessary supports etc. (steel) sqm. Tk. 498.00
07.2.8 Cornice, railing, drop walls, louver, fins etc. : Ground Floor
07.2.8.2 Formwork/shuttering, prop and necessary supports etc. (steel) sqm. Tk. 344.00
07.2.9.2 Formwork/shuttering, prop and necessary supports etc. (steel) sqm. Tk. 410.00
07.2.10.2 Formwork/shuttering, prop and necessary supports etc. (steel) sqm. Tk. 403.00
07.2.11.2 Formwork/shuttering, prop and necessary supports etc. (steel) sqm. Tk. 584.00
07.3 Reinforced cement concrete works using wooden shutter with minimum
cement content relates to mix ratio 1:2:4 having minimum f'cr = 27 Mpa, and
satisfying a specified compressive strength f’c = 22 Mpa at 28 days on standard
cylinders as per standard practice of Code ACI/BNBC/ASTM & Cement conforming
to BDS EN-197-1- CEM1, 52.5N (52.5MPa) / ASTM-C 150 Type – I, best quality
Sylhet sand or coarse sand of equivalent F.M. 2.2 and 20 mm down well graded
stone chips conforming to ASTM C-33, making, placing shutter in position and
maintaining true to plumb, making shutter water-tight properly, placing
reinforcement in position; mixing in standard mixer machine with hoper fed by
standard measuring boxes, casting in forms, compacting by vibrator machine and
curing at least for 28 days, removing centering-shuttering after specified time
approved; including cost of water, electricity, additional testing charges of materials
and cylinders required by engineer, other charges etc. all complete approved and
accepted by the Engineer. (Rate is excluding the cost of reinforcement and its
fabrication, placing and binding etc)
07.3.1.2 Formwork/shuttering, prop and necessary supports etc. (wooden) sqm. Tk. 354.00
07.3.2.2 Formwork/shuttering, prop and necessary supports etc. (wooden) sqm. Tk. 413.00
07.3.3.2 Formwork/shuttering, prop and necessary supports etc. (wooden) sqm. Tk. 355.00
07.3.4 Padestals, column capitals, lift walls and walls upto Ground Floor
07.3.4.2 Formwork/shuttering, prop and necessary supports etc. (wooden) sqm. Tk. 412.00
07.3.5.2 Formwork/shuttering, prop and necessary supports etc. (wooden) sqm. Tk. 394.00
07.3.6 Tee beams, Ell beams and Rectangular beams etc upto Ground Floor
07.3.6.2 Formwork/shuttering, prop and necessary supports etc. (wooden) sqm. Tk. 485.00
07.3.7.2 Formwork/shuttering, prop and necessary supports etc. (wooden) sqm. Tk. 459.00
07.3.8 Cornice, railing, drop walls, louver, fins etc upto Ground Floor
07.3.8.2 Formwork/shuttering, prop and necessary supports etc. (wooden) sqm. Tk. 344.00
07.3.9.2 Formwork/shuttering, prop and necessary supports etc. (wooden) sqm. Tk. 395.00
07.3.10.2 Formwork/shuttering, prop and necessary supports etc. (wooden) sqm. Tk. 381.00
07.3.11.2 Formwork/shuttering, prop and necessary supports etc. (wooden) sqm. Tk. 584.00
07.4 Reinforced cement concrete works using steel shutter with minimum cement
content relates to mix ratio 1:2:4 having minimum f 'cr = 27 Mpa, and satisfying a
specified compressive strength f 'c = 22 Mpa at 28 days on standard cylinders as
per standard practice of Code ACI/BNBC/ASTM & Cement conforming to BDS EN-
197-1- CEM1, 52.5N (52.5MPa) / ASTM-C 150 Type – I, best quality Sylhet sand or
coarse sand of equivalent F.M. 2.2 and 20 mm down well graded stone chips
conforming to ASTM C-33, making, placing shutter in position and maintaining true
to plumb, making shutter water-tight properly, placing reinforcement in position;
mixing in standard mixer machine with hoper fed by standard measuring boxes,
casting in forms, compacting by vibrator machine and curing at least for 28 days,
removing centering-shuttering after specified time approved; including cost of water,
electricity, additional testing charges of materials and cylinders required by
engineer, other charges etc. all complete approved and accepted by the Engineer.
(Rate is excluding the cost of reinforcement and its fabrication, placing and
binding etc)
07.4.1.2 Formwork/shuttering, prop and necessary supports etc. (steel) sqm. Tk. 382.00
07.4.2.2 Formwork/shuttering, prop and necessary supports etc. (steel) sqm. Tk. 391.00
07.4.3.2 Formwork/shuttering, prop and necessary supports etc. (steel) sqm. Tk. 323.00
07.4.4 Padestals, column, column capitals, lift walla and walls upto Ground Floor
07.4.4.2 Formwork/shuttering, prop and necessary supports etc. (steel) sqm. Tk. 373.00
07.4.5.2 Formwork/shuttering, prop and necessary supports etc. (steel) sqm. Tk. 380.00
07.4.6 Tee beams, Ell beams and Rectangular beams etc upto Ground Floor
07.4.6.2 Formwork/shuttering, prop and necessary supports etc. (steel) sqm. Tk. 415.00
07.4.7.2 Formwork/shuttering, prop and necessary supports etc. (steel) sqm. Tk. 498.00
07.4.8 Cornice, railing, drop walls, louver, fins etc. : Ground Floor
07.4.8.2 Formwork/shuttering, prop and necessary supports etc. (steel) sqm. Tk. 344.00
07.4.9.2 Formwork/shuttering, prop and necessary supports etc. (steel) sqm. Tk. 410.00
07.4.10.2 Formwork/shuttering, prop and necessary supports etc. (steel) sqm. Tk. 403.00
07.4.11.2 Formwork/shuttering, prop and necessary supports etc. (steel) sqm. Tk. 584.00
PWD SoR 2014 for Civil Works 89
07.5 Reinforced cement concrete works using wooden shutter with minimum
cement content relates to mix ratio 1:1.5:3 having minimum f 'cr = 26 Mpa, and
satisfying a specified compressive strength f 'c = 21 Mpa at 28 days on standard
cylinders as per standard practice of Code ACI/BNBC/ASTM & Cement conforming
to BDS EN-197-1- CEM1, 52.5N (52.5MPa) / ASTM-C 150 Type – I, best quality
Sylhet sand or coarse sand [F.M. 2.2] and 20 mm down well graded picked jhama
brick chips conforming to ASTM C-33, including breaking chips and screening,
making, placing shutter in position and maintaining true to plumb, making shutter
water-tight properly, placing reinforcement in position; mixing in standard mixer
machine with hoper and fed by standard measuring boxes, casting in forms,
compacting by vibrator machine and curing at least for 28 days, removing centering-
shuttering after specified time approved; including cost of water, electricity,
additional testing charges of materials and cylinders required by engineer, other
charges etc. all complete approved and accepted by the Engineer. (Rate is excluding
the cost of reinforcement and its fabrication, placing and binding etc)
07.5.1.2 Formwork/shuttering, prop and necessary supports etc. (wooden) sqm. Tk. 354.00
07.5.2.2 Formwork/shuttering, prop and necessary supports etc. (wooden) sqm. Tk. 413.00
07.5.3.2 Formwork/shuttering, prop and necessary supports etc. (wooden) sqm. Tk. 355.00
07.5.4 Padestals, column capitals, lift walls and walls upto Ground Floor
07.5.4.2 Formwork/shuttering, prop and necessary supports etc. (wooden) sqm. Tk. 412.00
07.5.5.2 Formwork/shuttering, prop and necessary supports etc. (wooden) sqm. Tk. 394.00
07.5.6 Tee beams, Ell beams and Rectangular beams etc upto Ground Floor
07.5.6.2 Formwork/shuttering, prop and necessary supports etc. (wooden) cum Tk. 485.00
07.5.7.2 Formwork/shuttering, prop and necessary supports etc. (wooden) sqm. Tk. 459.00
07.5.8 Cornice, railing, drop walls, louver, fins etc upto Ground Floor
07.5.8.2 Formwork/shuttering, prop and necessary supports etc. (wooden) sqm. Tk. 344.00
07.5.9.2 Formwork/shuttering, prop and necessary supports etc. (wooden) sqm. Tk. 395.00
07.5.10.2 Formwork/shuttering, prop and necessary supports etc. (wooden) sqm. Tk. 381.00
07.6 Reinforced cement concrete works using steel shutter with minimum cement
content relates to mix ratio 1:1.5:3 having minimum f'cr = 30 Mpa, and satisfying a
specified compressive strength f’c = 25 Mpa at 28 days on standard cylinders as per
standard practice of Code ACI/BNBC/ASTM & Cement conforming to BDS EN-197-
1- CEM1, 52.5N (52.5MPa) / ASTM-C 150 Type – I, best quality Sylhet sand or
coarse sand of equivalent F.M. 2.2 and 20 mm down well graded stone chips
conforming to ASTM C-33, making, placing shutter in position and maintaining true
to plumb, making shutter water-tight properly, placing reinforcement in position;
mixing with standard mixer machine with hopper, fed by standard measuring boxes,
casting in forms, compacting by vibrator machine and curing at least for 28 days,
removing centering-shuttering after specified time approved; including cost of water,
electricity, additional testing charges of materials and cylinders required by
engineer, other charges etc. all complete approved and accepted by the Engineer.
(Rate is excluding the cost of reinforcement and its fabrication, placing and
binding etc)
PWD SoR 2014 for Civil Works 91
07.6.1.2 Formwork/shuttering, prop and necessary supports etc. (steel) sqm. Tk. 382.00
07.6.2.2 Formwork/shuttering, prop and necessary supports etc. (steel) sqm. Tk. 391.00
07.6.3.2 Formwork/shuttering, prop and necessary supports etc. (steel) sqm. Tk. 323.00
07.6.4 Padestals, column, column capitals, lift walla and walls upto Ground Floor
07.6.4.2 Formwork/shuttering, prop and necessary supports etc. (steel) sqm. Tk. 373.00
07.6.5.2 Formwork/shuttering, prop and necessary supports etc. (steel) sqm. Tk. 380.00
07.6.6 Tee beams, Ell beams and Rectangular beams etc upto Ground Floor
07.6.6.1 Concrete cum Tk. 10,526.00
07.6.6.2 Formwork/shuttering, prop and necessary supports etc. (steel) sqm. Tk. 415.00
07.6.7 Floor and roof slab upto Ground Floor
07.6.7.1 Concrete cum Tk. 10,526.00
07.6.7.2 Formwork/shuttering, prop and necessary supports etc. (steel) sqm. Tk. 498.00
07.6.8 Cornice, railing, drop walls, louver, fins etc. : Ground Floor
07.6.8.1 Concrete cum Tk. 10,794.00
07.6.8.2 Formwork/shuttering, prop and necessary supports etc. (steel) sqm. Tk. 344.00
07.6.9 Sunshade, false ceiling : Ground Floor
07.6.9.1 Concrete cum Tk. 10,794.00
07.6.9.2 Formwork/shuttering, prop and necessary supports etc. (steel) sqm. Tk. 410.00
07.6.10 Stair case slab and steps upto Ground Floor
07.6.10.1 Concrete cum Tk. 10,794.00
07.6.10.2 Formwork/shuttering, prop and necessary supports etc. (steel) sqm. Tk. 403.00
PWD SoR 2014 for Civil Works 92
07.7 Reinforced cement concrete works using wooden shutter with minimum
cement content relates to mix ratio 1:1.5:3 having minimum f'cr = 30 Mpa, and
satisfying a specified compressive strength f’c = 25 Mpa at 28 days on standard
cylinders as per standard practice of Code ACI/BNBC/ASTM & Cement conforming
to BDS EN-197-1- CEM1, 52.5N (52.5MPa) / ASTM-C 150 Type – I, best quality
Sylhet sand or coarse sand of equivalent F.M. 2.2 and 20 mm down well graded
stone chips conforming to ASTM C-33, making, placing shutter in position and
maintaining true to plumb, making shutter water-tight properly, placing
reinforcement in position; mixing with standard mixer machine with hopper, fed by
standard measuring boxes, casting in forms, compacting by vibrator machine and
curing at least for 28 days, removing centering-shuttering after specified time
approved; including cost of water, electricity, additional testing charges of
materials and cylinders required by engineer, other charges etc. all complete
approved and accepted by the Engineer. (Rate is excluding the cost of reinforcement
and its fabrication, placing and binding etc)
07.7.1.2 Formwork/shuttering, prop and necessary supports etc. (wooden) sqm. Tk. 354.00
07.7.2.2 Formwork/shuttering, prop and necessary supports etc. (wooden) sqm. Tk. 413.00
07.7.3.2 Formwork/shuttering, prop and necessary supports etc. (wooden) sqm. Tk. 355.00
07.7.4 Padestals, column capitals, lift walls and walls upto Ground Floor
07.7.4.2 Formwork/shuttering, prop and necessary supports etc. (wooden) sqm. Tk. 412.00
PWD SoR 2014 for Civil Works 93
07.7.5.2 Formwork/shuttering, prop and necessary supports etc. (wooden) sqm. Tk. 394.00
07.7.6 Tee beams, Ell beams and Rectangular beams etc upto Ground Floor
07.7.6.2 Formwork/shuttering, prop and necessary supports etc. (wooden) sqm. Tk. 485.00
07.7.7.2 Formwork/shuttering, prop and necessary supports etc. (wooden) sqm. Tk. 459.00
07.7.8 Cornice, railing, drop walls, louver, fins etc upto Ground Floor
07.7.8.2 Formwork/shuttering, prop and necessary supports etc. (wooden) sqm. Tk. 344.00
07.7.9.2 Formwork/shuttering, prop and necessary supports etc. (wooden) sqm. Tk. 395.00
07.7.10.2 Formwork/shuttering, prop and necessary supports etc. (wooden) sqm. Tk. 381.00
07.7.11.2 Formwork/shuttering, prop and necessary supports etc. (wooden) sqm. Tk. 584.00
PWD SoR 2014 for Civil Works 94
07.8 Reinforced cement concrete works using steel shutter with minimum cement
content relates to mix ratio 1:1.25:2.5 having minimum f'cr = 40 Mpa, and
satisfying a specified compressive strength f’c = 32 Mpa at 28 days on standard
cylinders as per standard practice of Code ACI/BNBC/ASTM & Cement conforming
to BDS EN-197-1- CEM1, 52.5N (52.5MPa)/ ASTM-C 150 Type – I, and adding
approved high range water reducing admixture of complying specific type
(generally be Type-G) under ASTM-C 494, best quality coarse sand [Sylhet sand
or coarse sand of equivalent F.M. 2.2], 20 mm down well graded crushed stone chips
conforming to ASTM C-33, including breaking chips and screening through proper
sieves, making and placing shutter in position and maintaining true to plumb,
making shutter water-tight properly, placing reinforcement in position; mixing with
standard mixer machine with hoper and fed by standard measuring boxes, casting in
forms, compacting by vibrator machine and curing at least for 28 days, removing
centering-shuttering after specified time approved; including cost of water,
electricity, additional testing charges of materials and cylinders required by
engineer, other charges etc. all complete approved and accepted by the Engineer.
(Doses of admixture in the mix to be fixed by mix design) (Rate is excluding the
cost of reinforcement and its fabrication, placing and binding etc and admixture)
07.8.1.2 Formwork/shuttering, prop and necessary supports etc. (steel) sqm. Tk. 382.00
07.8.2.2 Formwork/shuttering, prop and necessary supports etc. (steel) sqm. Tk. 391.00
07.8.3.2 Formwork/shuttering, prop and necessary supports etc. (steel) sqm. Tk. 323.00
07.8.4 Padestals, column, column capitals, lift walla and walls upto Ground Floor
07.8.4.2 Formwork/shuttering, prop and necessary supports etc. (steel) sqm. Tk. 373.00
07.8.5.2 Formwork/shuttering, prop and necessary supports etc. (steel) sqm. Tk. 415.00
07.8.6 Tee beams, Ell beams and Rectangular beams etc upto Ground Floor
07.8.6.2 Formwork/shuttering, prop and necessary supports etc. (steel) sqm. Tk. 498.00
PWD SoR 2014 for Civil Works 95
07.8.7.2 Formwork/shuttering, prop and necessary supports etc. (steel) sqm. Tk. 403.00
07.8.8 Cornice, railing, drop walls, louver, fins etc. : Ground Floor
07.8.8.2 Formwork/shuttering, prop and necessary supports etc. (steel) sqm. Tk. 584.00
07.11 Formwork/shuttering, prop and necessary supports etc. (steel) sqm. Tk. 19.00
07.12 Stair case slab and steps upto Ground Floor cum Tk. 194.00
07.14 Formwork/shuttering, prop and necessary supports etc. (steel) sqm. Tk. 41.00
07.15 Waffle or Ribbed floor upto Ground Floor cum Tk. 194.00
07.17.1 Add for each addl. floor up to 5th floor cum Tk. 82.00
07.17.2 Add for each addl. floor from 6th floor to 9th floor cum Tk. 109.00
07.17.3 Add for each addl. floor for 10th floor & above cum Tk. 136.00
07.18 Extra rate for RCC work in additional floor: Formwork / shuttering including
curing
07.18.1 Add for each addl. floor up to 5th floor sqm. Tk. 31.00
07.18.2 Add for each addl. floor from 6th floor to 9th floor sqm. Tk. 46.00
07.18.3 Add for each addl. floor for 10th floor & above sqm. Tk. 62.00
07.19 Extra cost for making ‘as-cast’ surface of the concrete approved and accepted by sqm. Tk. 308.00
the Engineer. (formwork cost)
PWD SoR 2014 for Civil Works 96
07.20 Supplying, best quality pliable, cold applied pre-formed self adhesive rubberized/
bituminous water proofing membrane of approved brand / origin / manufacturer from
an authorized local agent or manufacturer having minimum thickness 1.5 mm, lined
with 2 ply cross laminated high density polyethylene film performances and
properties all conforming to ASTM standards and laying, placing, fixing on made up
firm and dry surfaces free from hollows, sharp protrusions, contaminates etc. laid
over-lap by at least 75 mm along the edges and 125 mm at ends ensuring good
initial bond with the surfaces all complete under the strict accordance with the
manufacturer recommendations and instructions providing all safety provisions in all
respects and accepted by the Engineer. (supplied by only manufacturer's authorised
dealer with certificate of origin ) under following specification:
Backing(HDPE) thickness minimum 0.10mm
Membrane thickness minimum 1.40mm
Total thickness minimum 1.50mm
Cold flexibility greater than (-) 200C : ASTM D146
07.20.1 Supply and use of water reducing chemical admixture in concrete, complying liter Tk. 189.00
ASTM C-494 Type - A of approved brand / origin / manufacturer and supplied by
only manufacturer's authorised dealer with certificate of origin : The admixture
is to reduce quantity of mixing water required for normal workability and to maintain
low water-cement (W/C) ratio, for improved concrete quality ensuarance.
07.20.2 Supply and use of retarding chemical admixture in concrete, complying ASTM liter Tk. 195.00
C-494 Type - B of approved brand/origin/manufacturer and supplied by only
manufacturer's authorised dealer with certificate of origin :The admixture for
retarding setting time of concrete, there by reducing shrinkage in concrete specially
for concrete laid in thick layers and intended delayed construction for improved
construction joints, re-concreting etc.
07.20.3 Supply and use of accelerating chemical admixture in concrete, complying liter Tk. 200.00
ASTM C-494 Type - C of approved brand/origin/manufacturer and supplied by
only manufacturer's authorised dealer with certificate of origin : An admixture
that is to accelerate the setting time and early strength gain of concrete.
07.20.4 Supply and use of water-reducing and retarding chemical admixture in concrete, liter Tk. 183.00
complying ASTM C-494 Type - D of approved brand/origin/manufacturer and
supplied by only manufacturer's authorised dealer with certificate of origin :
The admixture to reduce the quantity of mixing water required to produce concrete of
given consistency, i.e. low water-cement (W/C) ratio and intend to retard setting time
of concrete, specially for layered, thick laid concrete etc.
07.20.5 Supply and use of water-reducing and accelerating chemical admixture in liter Tk. 207.00
concrete, complying ASTM C-494 Type - E of approved brand/origin/manufacturer
and supplied by only manufacturer's authorised dealer with certificate of
origin : The admixture to reduce the quantity of mixing water required to produce
concrete of given consistency, i.e. low water-cement (W/C) ratio and intend to
accelerate setting time of concrete, and early strength gain in concrete etc.
07.20.6 Supply and use of water-reducing high range chemical admixture in concrete, liter Tk. 225.00
complying ASTM C-494 Type - F of approved brand/origin/manufacturer and
supplied by only manufacturer's authorised dealer with certificate of origin :
The admixture required to produce concrete of consistency by 12% or greater
(flowing concrete) and for higher strength of concrete.
PWD SoR 2014 for Civil Works 97
07.20.7 Supply and use of water-reducing high range and retarding chemical admixture liter Tk. 171.00
in concrete, complying ASTM C-494 Type - G of approved brand/origin/manufacturer
and supplied by only manufacturer's authorised dealer with certificate of
origin :The admixture required to produce concrete of consistency by 12% or
greater (flowing concrete) and for higher strength of concrete and intend to retard
setting time of concrete.
07.21 Supplying, best quality pliable, cold applied pre-formed self adhesive rubberized/
bituminous water proofing membrane of approved brand / origin / manufacturer from
an authorized local agent or manufacturer having minimum thickness 1.5 mm, lined
with 2 ply cross laminated high density polyethylene film performances and
properties all conforming to ASTM standards and laying, placing, fixing on made up
firm and dry surfaces free from hollows, sharp protrusions, contaminates etc. laid
over-lap by at least 75 mm along the edges and 125 mm at ends ensuring good
initial bond with the surfaces all complete under the strict accordance with the
manufacturer recommendations and instructions providing all safety provisions in all
respects and accepted by the Engineer. (supplied by only manufacturer's authorised
dealer with certificate of origin ) under following specification:
07.21.1 Water-proofing membrane on external surface of primed vertical or inclined wall /on sqm. Tk. 956.00
plastered and primed back-wall and concrete cast against membrane.
(Excluding cost of back fill/brick wall on back/plaster when membrane laid on back-
wall and concrete cast against membrane which to be paid as per corresponding
items in this schedule)
07.21.2 Water-proofing membrane on made up surface below the floor or below the sqm. Tk. 855.00
horizontal surfaces with temporary protective cover using polysterene/1.5" thick
sand-cement mortar in 4:1 /or by equally effective alternative. (Rate is excluding the
cost of protective cover which to be paid as per corresponding items in this schedule)
07.21.3 Water-proofing membrane on the floor or on the horizontal surfaces with permanent sqm. Tk. 891.00
protective cover & wearing coarse. (Rate is excluding the cost of protective cover
and wearing coarse which to be paid as per corresponding items in this schedule)
PWD SoR 2014 for Civil Works 98
07.22 20 mm thick water-proofing work in masonry or on concrete surface with sand- sqm. Tk. 508.00
cement mortar mixed with specified admixture (supplied from authorized local
agent or from manufacturer comply with ASTM/BS/IS requirements, confirming
current compliance of the admixture to specification requirements like physical
properties, uniformity and equivalence in composition, performance requirements,
delivered in sealed containers having and confirming plainly marked the proprietary
name of the admixture type under this specification, net weight and or volume,
manufacturing and expiry date, shelve life, non aggressiveness to environment and
metals in concrete etc.) under the strict accordance with manufacturer
recommendations / instructions and providing safety provisions in all respect etc. on
sound, firm surfaces all complete including cleaning the surface from dust, loose
particles, remains of oil, grease etc. all complete approved and accepted by the
Engineer. (Cement: CEM-II/A-M)
08.1 Supplying, fabrication, and fixing to details as per design : Ribbed or deformed bar
reinforcement for Reinforced Cement Concrete, produced and marked in
accordance with BDS ISO 6935 - 2: 2006 (or standard subsequently released
from BSTI) including straightening and cleaning rust, if any, bending and binding in
position with supply of G.I. wires, splices or laps what so ever etc. complete in all
respects and accepted by the Engineer ( Measurement shall be recorded only on
Standard Mass per Unit length of Bars, while, dia of bars exceeds its standard)
08.1.1 Grade 300 ( RB 300 : complying BDS ISO 6935-2:2006) ribbed or deformed bar Per kg Tk. 81.91
produced and marked according to Bangladesh Standard with minimum yield
strength, fy (ReH)= 300MPa,but fy not exceeding 314MPa and what ever is the
yield strength within allowable limit as per BNBC sec 8.3.3.5 / ACI 318-11 sec
21.1.5.2, the ratio of ultimate tensile strength fu to yield strength fy, shall be at
least 1.25 and minimum elongation after fracture and minimum total elongation at
maximum force is 17% and 8% respectively : up to ground floor
Per kg Tk. 85.00
08.1.2 Grade 400 (RB 400 / 400W: complying BDS ISO 6935-2:2006) ribbed or deformed
bar produced and marked according to Bangladesh Standard, with minimum yield
strength, fy (ReH)= 400 Mpa but fy not exceeding 418MPa and what ever is the
yield strength within allowable limit as per BNBC sec 8.3.3.5 /ACI 318-11 sec
21.1.5.2, the ratio ultimate tensile strength fu to yield strength fy, shall be at
least 1.25 and minimum elongation after fracture and minimum total elongation at
maximum force is 16% and 8% respectively : up to ground floor
08.2 Extra rate for M.S. Fabrication work in additional floor shall be incorporated in the
estimate
08.2.1 Add for each addl. floor up to 5th floor Per kg Tk. 0.39
08.2.2 Add for each addl. floor from 6th floor to 9th floor Per kg Tk. 0.77
08.2.3 Add for each addl. floor for 10th floor and above Per kg Tk. 1.15
08.3 Mild steel Grade 250 with minimum fy = 250 MPa work in roof truss: supplying and Per kg Tk. 125.00
fabrication of mild steel sections as per design. Hoisting, fitting and fixing in position
with bolts and nuts or rivets or welded and providing two coats of anti-corrosive paint
over a prime coat of red oxide paint etc. complete and accepted by the
Engineer.(Measurement to be given for Truss member only).
08.4 Supplying fan hook 300-grade ( RB300) of 16 mm diameter M.S. rod (one meter each Tk. 103.00
straight length) having rounded hook at the middle of bar in proper size so as to be
concealed within fan cup including fabrication and fitting fixing in all floor accepted by
the Engineer.
08.5.3 With Aluminium sheet and 6 mm x 75 mm size M.S. plate. rm. Tk. 2,399.00
08.6 Supplying, fitting and fixing PVC water stopper at RCC construction joint in rm. Tk. 850.00
basements providing 1.5" x 2.5" wooden batten at the top and bottom of water
stopper, binding in place with GI wires etc.
08.7 Supplying, fitting and fixing 10" wide 16 SWG Aluminium Sheet water stopper in rm. Tk. 286.00
construction joint of RCC vertical.
08.8 Providing bearing joints fixed or free with 250 x 375 x 10 mm M.S. (Grade - A36) each Tk. 3,146.00
shoe plate fitted in the truss angles with 16 mm diameter M.S. rod counter sunk
rivets, welded and anchored to 250 x 375 x 10 mm .M.S shoe plate by two Nos. 19
mm dia M.S. “U” rod embedded in the bed of the lintel around the reinforcement,
cleaning and greasing the joints for all floors etc. all complete and accepted by the
Engineer.
09.1 Boring/drilling for cast in situ pile up to the required depth and diameter with
minimum 6 m long temporary steel casing, true to vertical, providing bentonite slurry
and maintaining water level in the hole, washing the hole for at least 30 minutes,
clean the bore-hole and make the bore- hole ready for placing steel cage and
concreting including hire charge of rig set with winch machine, tripod stand, trimie
pipe, cost of fuel, lubricant, mobilization, demobilization, maintenance, spares, stand-
byes, insurance coverage, water, electricity and other charges all compete approved
and accepted by the Engineer. Before commencing boring operation Contractor shall
submit the method statement of cast-in-situ pile work including sequence of boring
and casting, disposal of spoils, test result of materials to the Engineer for approval.
However, Engineer’s approval shall not relieve the Contractor of his responsibilities
and obligations under contract.
09.1.1.2 Additional rate for each additional meter beyond 20 m up to 29 m rm Tk. 4.00
09.1.2.2 Additional rate for each additional meter beyond 20 m up to 29 m rm Tk. 5.00
09.1.3.2 Additional rate for each additional meter beyond 20 m up to 29 m rm Tk. 7.00
09.1.4.2 Additional rate for each additional meter beyond 20 m up to 29 m rm Tk. 8.00
09.1.5 600 mm
09.1.5.2 Additional rate for each additional meter beyond 20 m up to 29 m rm Tk. 9.00
PWD SoR 2014 for Civil Works 102
09.2 Removing of spoils / mud accumulated during boring for cast in situ pile by wash cum Tk. 378.00
boring from working site to a safe distance by contractors own arrangement i.e. with
container set in truck or on cart including loading, unloading everything complete as
per standard practice. (Quantity should be given three times of solid volume of
boring)
09.3 Cast in situ pile with reinforced cement concrete works of high slump by adding high cum Tk. 11,578.00
range water reducing admixture (ASTM C494 Type A or F complying item 7.20.1 or
7.20.6) with minimum cement content relates to mix ratio 1 : 1.5 : 3 having minimum
f'cr = 26 Mpa, and satisfying a specified compressive strength f’c = 21 Mpa at 28
days on standard cylinders as per standard practice of Code ACI/BNBC/ASTM &
cement conforming to BDS EN-197-1- CEM1, 52.5N (52.5MPa) / ASTM-C 150 Type
– I, best quality coarse sand [Sylhet sand or coarse sand of equivalent F.M.2.2], 20
mm down well graded crushed stone chips conforming to ASTM C-33, including
breaking chips, screening through proper sieves, making, placing re-bar cage in
position, placing and removing tri-pod as per requirement, pouring the concrete in
bore-hole with the help of a trimie pipe, maintaining the trimie pipe immersed in
concrete by at least 1 meter throughout the period of concreting, maintaining
required slump, etc. mixing the aggregates with standard mixer machine with hoper,
casting in forms, all complete including water, electricity, testing of materials and
concrete etc and other charges as per design, drawing etc all complete approved
and accepted by the Engineer. (Rate is excluding the cost of reinforcement and its
fabrication, binding, welding , placing and admixture ( approx doses 150 to 250ltr per
bag of cement which to fix by mix design) )
09.4 Providing and making point welding at contact point of the spiral binders at point 3.9
reasonable intervals with the main reinforcements by electric arc welding for
construction of cast in situ bored pile carefully with highly oxidized electrodes making
the points prominent and accepted by the Engineer (rate is inclusive of all materials
labour, tools and plants, electricity and all equipment).
09.5 Providing and making welded splice over two sides of contact by welding of rm of Tk. 472.83
minimum 300 mm length at the lap of main reinforcement in re-bar cage to be placed weld
in bore-hole where necessary by electric arc welding with highly oxidized electrodes
making the joint prominent and accepted by the Engineer. (rate is inclusive of all
materials labour, tools and plants, electricity and all equipment).
09.6 Labour for breaking head of hardened cast in situ bored pile/pre-cast pile up to cum Tk. 3,603.00
a required length by any means but without damaging the rest and removing the
dismantled materials such as concrete to a safe distance including scraps and
cleaning concrete from steel/M.S. rods, straightening and bending of pile bars,
preparation and making platform where necessary, carrying, all sorts of handling,
stacking the same properly after clearing, leveling and dressing the situ and clearing
the bed etc. complete in all respects and accepted by the Engineer.
(Measurement will be given for the actual pile head volume to be broken)
PWD SoR 2014 for Civil Works 103
Load Test and Report shall be conducted under the supervission of a professional
Geotechnical Engineer registered in BPERB or Geotechnical Firm registerd in PWD.
Boring and Pouring logs / Driving logs of Piles and Method statement shall be the
part of load test report. (Rates on Load test under the supervision of Experts in the
laboratory of unversities and HBRI can be found in Chapter-32)
09.7.1 For 25 tonne load 1 No. of test Per test Tk. 53,423.00
09.7.2 For 75 tonne load for 1 No. of test Per test Tk. 100,856.00
09.7.3 For 125 tonne load for 1 No. of test Per test Tk. 138,368.00
09.7.4 For 175 tonne load for 1 No. test Per test Tk. 198,458.00
09.7.5 For 225 tonne load for 1 No. test Per test Tk. 245,302.00
09.7.6 For 275 tonne load for 1 No. of test Per test Tk. 293,566.00
09.8 Rate for increamental loading
09.8.1 For intermediate loading from 25 tonne to 75 tonne for each additional tonne Per Tk. 1,050.83
tonne
09.8.2 For intermediate loading from 75 tonne to 125 tonne for each additional tonne. Per Tk. 1,050.83
tonne
09.8.3 For intermediate loading from 125 tonne to 175 tonne for each additional tonne. Per Tk. 1,050.83
tonne
09.8.4 For intermediate loading from 175 tonne to 225 tonne for each additional tonne. Per Tk. 1,050.83
tonne
09.8.5 For intermediate loading from 225 tonne to 275 tonne for each additional tonne. Per Tk. 1,050.83
tonne
PWD SoR 2014 for Civil Works 104
09.9 Pre-cast pile made in reinforced cement concrete with minimum cement content
relates to mix ratio 1:1.5:3 having minimum f'cr = 30 Mpa, and satisfying specified
compressive strength f’c = 25 Mpa at 28 days on standard cylinders as per standard
practice of Code ACI/BNBC/ASTM & cement conforming to BDS EN-197-1- CEM1,
52.5N (52.5MPa) / ASTM-C 150 Type – I, best quality coarse sand (F.M.2.2), 20 mm
down well graded stone chips conforming to ASTM C-33, mixing in standard mixture
machine and fed by standard measuring boxes, including all related works like cost
of breaking chips, screening through proper sieves, cleaning and washing, centering
and shuttering with M.S sheet, M.S angle, F.I bar, nuts and bolts, champering edges
if so, preparation of casting beds, laying polythene there in, placing reinforcement
cages in position, casting, compacting by vibrators and tapered rods as where
necessary, curing for 28 days etc. cost of water, electricity and other charges,
providing fitting fixing pile shoe in position as per design and drawing, tools, plants &
equipments, mobilization, demobilization, hire charge of driving set, labour, test of
materials and concrete etc. all complete as per design, drawing and accepted by the
Engineer. (Rate is excluding the cost of reinforcement and its fabrication, binding,
welding and placing)
09.9.1 250 mm x 250 mm size pre-cast pile (1:1.5:3) with stone chips rm Tk. 850.00
09.9.2 300 mm x 300 mm size pre-cast pile (1:1.5:3) with stone chips rm Tk. 1,176.00
09.9.3 360 mm x 360 mm size pre-cast pile (1:1.5:3) with stone chips rm Tk. 1,520.00
09.9.4 Pile shoe as per design and drawing each Tk. 2,559.00
09.10 Mobilization and demobilization of drop hammer type pre-cast pile driving rig. Per set Tk. 3,417.00
per site
09.11 Driving 250 mm x 250 mm size pre-cast pile with drop hammer type rig, and
maintaining Driving Log in prescibed format Before commencing driving
operation, Contractor shall submit method statement for carrying the driving
operation including sequence of driving to the Engineer for approval. However,
Engineer’s approval shall not relieve the Contractor of his responsibilities and
obligations under contract.
09.12 Driving 300 mm x 300 mm size pre-cast pile with drop hammer type rig and
maintaining Driving Log in prescibed format. Before commencing driving
operation, Contractor shall submit method statement for carrying the driving
operation including sequence of driving to the Engineer for approval. However,
Engineer’s approval shall not relieve the Contractor of his responsibilities and
obligations under contract.
09.13 Driving 360 mm x 360 mm size pre-cast pile with drop hammer type rig and
maintaining Driving Log in prescibed format. Before commencing driving
operation, Contractor shall submit method statement for carrying the driving
operation including sequence of driving to the Engineer for approval. However,
Engineer’s approval shall not relieve the Contractor of his responsibilities and
obligations under contract.
09.18 Pre-cast driven micro-pile with reinforced cement concrete works with minimum
cement content relates to mix ratio 1:1.25:2.5 having minimum f'cr = 35 Mpa, and
satisfying a specified compressive strength f’c = 30 Mpa at 28 days on standard
cylinders as per standard practice of Code ACI/BNBC/ASTM & cement conforming to
BDS EN-197-1- CEM1,52.5N (52.5MPa) / ASTM-C 150 Type – I, best quality coarse
sand (F.M.2.5) and 20 mm down well-graded stone chips conforming to ASTM C-33,
mixing in standard mixture machine with hoper and fed by standard measuring
boxes, including cost of breaking chips, screening through proper sieves, cleaning
and washing, centering and shuttering with M.S sheet, M.S angle, F.I bar, nuts and
bolts, preparation of bed, laying polythene, placing of reinforcement cage, casting,
compacting by vibrators and tapered rods, curing for 28 days etc. including cost of
water, electricity and other charges, providing pile shoe as per design and drawing,
driving the pile up to the design depth as per standard practice or specified method
providing head cushion, all equipments including mobilization, demobilization and
hire charge of driving set, shampering, test of materials and concrete etc. including
carrying all complete approved and accepted by the Engineer. (Rate is excluding the
cost of reinforcement and its fabrication, binding, welding and placing and driving
pile)
PWD SoR 2014 for Civil Works 106
09.18.1 180 mm x180 mm x 7.6 m Pile with reinforced cement concrete (1 : 1.25 : 2.5) with rm Tk. 463.00
stone chips
09.18.2 205 mm x 205 mm x 7.6 m Pile with reinforced cement concrete (1 : 1.25 : 2.5) with rm Tk. 576.00
stone chips
09.18.3 Driving of 180 mm x 180 mm x 7.6 m Pre-cast Pile,and maintaining Driving Log in rm Tk. 170.00
prescibed format
09.18.4 Driving of 205 mm x 205 mm x 7.6 m Pre-cast Pile, and maintaining Driving Log in rm Tk. 200.00
prescibed format
09.19 PDA (Pile Driving Analyzer) Test : Conducting High Strain Dynamic Testing of
piles by an expert & licensed usre of the software(s) as per ASTM D4945, providing
all relevant materials ,equipment,experts,labors,mobilization and demobilization,data
acquisition, CAPWAP analysis, preperation of resultsin standard formsetc. complete
in all respects, approved and accepted by the engineer, where, report shall contain
relevant pile log, prevailing soil investigation report at the place, copy of expertise &
licensing.
09.19.1 PDA test upto 200 metric ton as ultiumate pile capacity : only one pile at a site to each Tk. 162,377.00
test in single run
09.19.2 PDA test upto 200 metric ton as ultiumate pile capacity : upto two pile at a site to each Tk. 148,060.00
test in single run
09.19.3 PDA test upto 200 metric ton as ultiumate pile capacity : upto three pile at a site to each Tk. 135,426.00
test in single run
09.19.4 PDA test upto 200 metric ton as ultiumate pile capacity : upto four pile at a site to each Tk. 124,253.00
test in single run
09.19.5 PDA test upto 200 metric ton as ultiumate pile capacity : five pile at a site to test in each Tk. 114,349.00
single run (Each successive rates for more than five test piles at a site in single run
may be asked)
09.20 PIT (Pile integrity test) : Conducting low strain dynamic testing of pile as per ASTM
D5882-The standard method for low-strain integrity testing of pile by a qualified and
approved PIT expert, preparing pile heads and providing all relevant materials,
equipment, experts, labour, mobilization, demobilization, data acquisition and
analysis, preparation of results in standard forms and compiling final report with
recommendations on the tests etc. complete in all respects approved and accepted
by the Engineer. (Report shall contain driving log / Boring and pouring logs, Graphs
& Statement on "Calliberation Pile" (pile that tested for its capacity and PIT done
eralier on it, at a place of known soil profiles), Soil investigation report. (Caliberation
pile shall be made and tested first).
Method statement for conducting PIT shall be submitted the Engineer for approval,
and shall be the part of PIT report, However, Engineer's approval shall not relieve
the contractor of his responsibilities and obligations under contract.
09.20.1 Mobilization & demobilization within 100km of Dhaka to site and PIT on12(twelve) upto 1st Tk. 24,021.00
Piles or less 12pile
09.20.2 Additional charge on Mobilization & demobilization beyond 100km off Dhaka to site per km Tk. 30.00
PWD SoR 2014 for Civil Works 107
09.20.3 For PIT test of each additional pile after 12(twelve) pile tested. per pile Tk. 1,201.00
09.21 Pre-cast spliced pile jointing by supplying, fitting, fixing prefabricated square shaped
two steel caps made up by 6mm thick ASTM A36 complied M.S plate, sides formed
by bent in channel shape to have only two line of joinery on faces, having min 50 mm
dia hole on its web; capping by min 12 mm thick ASTM A36 complied M.S plate
shaping the edges in 45°, having min 40 mm dia hole at centre to pass 25 mm M.S
bar 433 mm in length; jointed at channels root by welding; caps fitted with 2 nos BDS
ISO 6935-2009: B420 DWR complied d20 U-bar 1244mm in length by welding,
equidistance from centre holes of cap and shall have min 75 mm clear from pile
faces; and finally, the system be fitted in correct alignments on pile head positions
waiting for concreting; both the pile heads fitted with the steel caps be welded
together through v-notehes in field, while one of the companion segment of piles
drived in ground and other one placed over it maintaining true verticality; all complete
as per direction and stepwise approval leading to final approval of Engineer in
charge.
09.21.1 X-sec of pre cast pile segments :16"x16" each Tk. 13,568
09.21.2 X-sec of pre cast pile segments :14"x14" each Tk. 11,777
09.21.3 X-sec of pre cast pile segments :12"x12" each Tk. 10,159
09.22.1 Driving pre-cast pile made in square cut ends(tip) without shoe of any size in per rm Tk. 932
the range, 250mmx250mm to 450mmx450mm having pile segment up to 21.0m in
length; by Hydraulic Static Pile driver of approx. 180.00 tonne (metric ton) capacity;
arranged with necessary cranes, power source, maintaining driving log and record of
pressure exerted on piles driven in to desired RL or Capacity level ; complete in all
respect including mobilizing demobilizing of machines & equipment, handling of
piles, dressing & leveling of site, way making, surveying, layout setting etc ended
with the submission of pile driving report in three copies duly signed by professional
engineer and approved by the engineer.
09.22.1.1 Making Pre-Cast Piles with Square Cut ends with lengths upto 21.0m in per cum Tk. 22,807.04
reinforced cement concrete works having minimum cement content relates to mix
ratio 1:1.5:3, leading minimum f'cr = 30 Mpa, and satisfying specified compressive
strength f’c = 25 Mpa at 28 days on standard cylinders as per standard practice of
Code ACI/BNBC/ASTM & cement conforming to BDS EN-197-1- CEM1,52.5N
(52.5MPa) / ASTM-C 150 Type – I, best quality coarse sand (F.M.2.2), 20 mm down
well graded stone chips conforming to ASTM C-33, mixing in standard mixture
machine fitted with hopper and fed by standard measuring boxes, including all
related works like cost of breaking chips, screening through proper sieves, cleaning
and washing, centering and shuttering with M.S sheet, M.S angle, F.I bar, nuts and
bolts, champering edges if so, preparation of casting beds, laying polythene there
in, providing reinforcement & placing fitting fixing in position, casting concrete,
compacting by vibrators and tapered rods as where necessary, curing for 28 days
etc. cost of water, electricity and other charges, as per design and drawing, tools,
plants & equipments, mobilization, demobilization, labour, test of materials and
concrete etc. complete in all respect as per design, drawing and accepted by the
Engineer.
10.1 Supplying, fitting and fixing 0.457 mm thick corrugated galvanized iron sheet
(Bangladesh made) having min weight 63-65 kg per bundle (2'-6" width 70 – 72 rft
long) fitted and fixed on M.S. sections with 'J' hook or wooden purlin with screws,
limpet washers and putty etc. all complete and accepted by the Engineer.
10.2 Supplying, fitting and fixing 1.5 mm thick fiber glass sheet roofing fitted and fixed sqm Tk. 1,240.00
on M.S. sections with 'J' hook or wooden purlin with screws, limpet washers and
putty etc. all complete and accepted by the Engineer.
10.3 0.27 mm thick galvanized iron plain sheet ridging with 300 mm lap on either side
fitted and fixed with galvanized bolts and nuts etc. all complete and accepted by the
Engineer.
10.4 1.5 mm thick plain fiberglass sheet ridging with 300 mm lap on either side fitted rm Tk. 618.00
and fixed with galvanized bolts and nuts etc. all complete and accepted by the
Engineer.
10.5 Saftey Canopy: Supplying temporary safety canopy & around construction work sqm Tk. 1,531.00
place where public safety is possibly be endangered due to constructional activities,
which shall be made of aligning truss system of steel sections at 1800 mm c/c as
maximum and making flooring system by corrugated galvanized iron sheets of
approx 0.45mm thick. Placed on steel sections aligned perpendicular to truss at 900
mm c/c as maximum. All fitted. Fixed in position providing necessary anchors,
cables, wires, ties etc. by standard anchoring & welding, nut-bolts etc, all complete
and certified for safe and accepted by the Engineer
11.1 Supplying and making door and window frames (Chowkat) for all floors with
matured natural seasoned wood of required size including painting two coats of coal
tar to the surface in contact with wall, fitting and fixing in position etc. complete and
accepted by the Engineer. (All sizes of wood are finished).
11.2 Supplying, fitting and fixing M.S. flat bar clamp of 225 x 38 x 6 mm size having each Tk. 86.00
bifurcated ends to door and window frames with necessary screws and encasing
inside the wall with cement concrete (1:2:4) etc. complete and accepted by the
Engineer.
11.3 Supplying, fitting and fixing M.S. flat bar clamp 150 x 38 x 6 mm size having each Tk. 89.00
bifurcated ends to door and window frames with rowel plug, necessary screws etc.
including cutting groove in Chowkat if necessary etc. complete in all respect
accepted by the Engineer.
11.4 Supplying, fitting and fixing double leaf door frame for all floors with 38 x 38 x 6 mm rm Tk. 563.00
M.S. angle fitted with 250 mm long 6 Nos. of iron clamps of same size (with one end
bifurcated) with the vertical members of the frame, fixing the frame in wall with
cement concrete (1:2:4), mending good the damages, fixing 6 Nos. of 100 mm size
iron hinges with the vertical members of the frame all complete including cutting,
sizing, welding, fabricating, carrying from work-shop to site and local carriage, curing
etc. complete as per plan and drawing and accepted by the Engineer.
11.5 Supplying, fitting and fixing of door frame for single leaf in all floors with 38 x 38 x 6 rm Tk. 554.00
mm M.S. angle, fixing 130 mm long 6 Nos. of iron clamps of same size (with one end
bifurcated) with the vertical members of the frame, fixing the frame in wall with
cement concrete (1:2:4), mending good the damages, fixing 4 Nos. of 100 mm size
iron hinges with the vertical members of the frame all complete including cutting,
sizing, welding, fabricating, carriage from workshop to site including local carriage,
curing etc. as per plan and drawing etc. all complete and accepted by the Engineer.
(Running meter of the doorframe will be considered towards measurement).
11.6 Supplying seasoned wood and making roof truss of any size with wall plates as
per design in/c supplying, fabricating and hoisting, scaffolding, fitting and fixing in
position with bolts, nuts, coal tarring in 2 coats etc. all complete and accepted by the
Engineer.
(All sizes of wood are finished).
11.7 Supplying and making seasoned wooden hand rail of stair case etc. including
necessary molding with proper corner finishing as per design, fitted and fixed in
position in all floors etc. all complete and accepted by the Engineer.
12.1 Supplying, fitting and fixing 38 mm thick well matured, seasoned (min 10" wide
plank) solid wood single leaf door shutter having top rail style of sections 100 mm
x 38 mm, lock rail 125 x 38 mm and bottom rail 225 x 38 mm. Closed joints with 25
mm x 12 mm size wooden peg and provided with best quality 4 Nos. 100 mm iron
hinges 2 (two) Nos. best quality 12 mm dia 300 mm and 200 mm long iron tower and
socket bolts, 2 (two) Nos. heavy type nickel plated handle, hinged cleats, buffer
blocks and finished by sand papering etc. all complete in all floors and accepted by
the Engineer.(All sizes of wood are finished)
12.2 Supplying, fitting and fixing 38 mm thick well matured, natural seasoned (min 10"
wide plank) solid wood single leaf flush door shutter having a frame of top lock
and bottom rail of sections 100 mm x 12 mm styles 100 mm x 38 mm covered with
100 mm x 12 mm plank, screwed to each face and provided with best quality 4 Nos.
100 mm iron hinges, 2 (two) Nos. best quality 12 mm dia 300 mm and 200 mm long
iron tower and socket bolts, 2 (two) Nos. heavy type nickel plated handles, hinged
cleats, buffer blocks and finished by sand papering etc. all complete in all floors and
accepted by the Engineer. (All sizes of wood are finished)
12.3 Supplying, fitting and fixing 38 mm finished well matured, natural seasoned (min 10" sqm Tk. 14,344.00
wide plank) wooden ornamental special design (equivalent hatil) both sides single
panel flush door shutter with top and middle rail 150 mm x 38mm bottom rail 225
mm x 38 mm and style 125 mm x 38 mm, having vertical panels 175 mm x 38 mm
in./c minimum 12 mm lap to each panel providing 4 nos, best quality 100 mm brass
hinges, 12 mm dia best quality 200 mm & 300 mm brass socket and tower bolts
2(two) now heavy type best quality brass handle hinges cleats, wooden buffer blocks
in/c supply of necessary nails and screws finished by making design by machine
finished etc. all complete in all floors and accepted by the Engineer (Ctg. teak
wood).
PWD SoR 2014 for Civil Works 112
12.4 Supplying, fitting and fixing 38 mm thick well matured, natural seasoned (min 10"
wide plank) wooden double leaf panel door shutters. Top rail and styles of
sections 100 mm x 38 mm, lock rail 125 mm x 38 mm and bottom rail 225mm x 38
mm, paneling 38 mm thick both sides raised, provided with best quality 6 Nos. 100
mm iron hinges, 2 (two) Nos. best quality 12 mm dia 300 mm and 225 mm long iron
tower and socket bolts, 2 (two) Nos. heavy type nickel plated handle, 1 No. hatch-
bolt hinged cleats, buffer blocks and finished by sand papering, necessary screws
etc. all complete in all floors and accepted by the Engineer. (Double leaf. All sizes of
wood are finished)
12.5 Supplying, fitting and fixing 38 mm thick well matured, natural seasoned (min.10"
wide plank) wooden double leaf panel door shutters. Top rail and styles of
sections 100 mm x 38 mm. lock rail 125 mm x 38 mm and bottom rail 225 mm x 38
mm. paneling 25 mm thick one side raised, provided with best quality 6 nos. 100 mm
iron hinges, 2 (two) Nos. best quality 12 mm dia 300 mm and 200 mm long iron
tower and socket bolts, 2 (two) Nos. heavy type nickel plated handles, 1 No. hatch-
bolt hinged cleats, buffer blocks and finished by sand papering, necessary screws
etc. all complete in all floors and accepted by the Engineer.(Double leaf. All sizes of
wood are finished)
12.6 Supplying, fitting and fixing 38 mm finished thick well matured, natural seasoned
(min. 10" wide plank) wooden grooved single panel flush door shutters with top
and middle rail 100 mm x 38 mm, bottom rail 225 mm x 38 mm and style 100 mm x
38 mm, having vertical panels 100 x 38 mm including keeping 6 mm x 12 mm even
groove all around and minimum 12 mm grooved lap to each panel. Providing 4 Nos.
best quality 100 mm iron hinges, 12 mm dia best quality 200 mm and 300 mm iron
socket and tower bolts, 2 (two) Nos. heavy type best quality nickel plated handle
hinged cleats, wooden buffer blocks including supply of necessary nails and screws,
finished by sand papering etc. complete in all respect in all floors as per drawing and
as per standard practice and accepted by the Engineer. (All sizes of wood are
finished).
12.7 Supplying, fitting and fixing 36 mm thick and having density 400 kg/cum solid
particle board single leaf flush door for all floors for internal use made of well
matured mechanical seasoned Rubber (Malaysian timber) or other approved wooden
frame having finished size 35 x 50 mm around upon which 1.2 mm thick veneer (total
two Nos. of veneers one of 0.7 mm horizontally made of gorjon and another of 0.5
mm vertically made of Burma Teak or Champa or Chapalish or Garjan wood) with
necessary screws are pested on each side by mechanized process and provided
with best quality 4 Nos. 100 mm iron hinges, 2 Nos. best quality 12 mm iron dia 300
mm and 225 mm long iron tower and socket bolts, 2 (two) Nos. heavy type nickel
plated handles, hinged cleats, buffer blocks etc. complete and accepted by the
Engineer.
12.8 Manufacturing and supplying, fitting, fixing well matured, natural seasoned (min 10"
wide plank) wooden fixed louver shutters having 62 x 125 mm frame and inner
horizontal wooden louver 150 x 25 mm size spaced @ 50 mm c/c fixed with frame in
grooves including cost of screws, nails, 12 mm x 12 mm size wooden bit, preparing
the surface by sand papering etc. complete in all respect as per drawing and
accepted by the Engineer. (All sizes of wood are finished).
12.9 Supplying, fitting and fixing well matured, natural seasoned (min 10” wide plank)
wooden glazed ventilator louver shutters for all floors having wooden outer frame
of section 62 x 125 mm (finished) with 62 x 125 mm (finished) size vertical divider
with inner 50 mm x 38 mm shutter and with 3 Nos. horizontal 38 mm x 38 mm sash
bar in each part and inner horizontal glazed louver of size 150 x 6 mm (local) fixed in
frame @ 154 mm c/c by cutting grooves in the frame including cost of screws,
wooden bit, pivots, sand papering, cutting glass to required size etc. all complete as
per design, drawing and as per standard practice and accepted by the Engineer. (All
sizes of wood are finished).
12.10 Supplying fitting and fixing 38 mm thick well matured, natural seasoned (min 10"
wide plank) wooden door shutters for all floors having styles and rails of section
150 mm x 38 mm and 5 mm glass panes fitted and fixed with wooden batten, putty
and nails including supplying and fitting and fixing 50 mm dia best quality round door
lock. 12 mm dia, 1200 mm long iron tower bolt and 8 Nos. 100 mm iron hinges to
each shutters, 2 Nos. nickel plated handle, hinged cleats, buffer blocks, screws,
finished with necessary sand papering and putty works etc. complete and accepted
by the Engineer. (All sizes of wood are finished).
12.11 Supplying, fitting and fixing 25 mm thick well matured natural seasoned (min 10” sqm Tk. 5,505.00
wide plank) Kathal wood door and window shutters for all floors having 75 x 25
mm ‘Z’ battens, provided with best quality 3 Nos. 100 mm iron hinges, 2 Nos. 62 mm
dia iron ring fitted with nuts, 2 Nos. best quality 12 mm dia, 300 mm and 225 mm
long iron tower and socket bolts, hinged cleats, buffer blocks, screws and finished
with sand papering in all floors etc. complete and accepted by the Engineer. (All
sizes of wood are finished).
12.12 Supplying, fitting and fixing 38 mm thick well matured natural seasoned (min 10"
wide plank) wood glazed window shutters for all floors having horizontal and
vertical sections of 87 x 38 mm and sash bar 38 x 38 mm fitted with 3 mm glass
panes with putty and nails and provided with best quality 4 Nos. 75 mm iron hinges,
2 (two) Nos. best quality 12 mm dia 250 mm and 150 mm long iron tower and socket
bolts, nickel plated handles 225 mm long catch hooks or hinged cleats, buffer blocks,
necessary screws and finished with sand papering for all floors etc. complete and
accepted by the Engineer. (All sizes of wood are finished).
12.13 Supplying, fitting and fixing 38 mm thick well matured, seasoned (min 10" wide
plank) wood window shutter one third glazed and two third raised paneling on
both sides and 38 mm thick for all floors having horizontal and vertical sections of 87
mm x 38 mm and sash bars 38 x 38 mm fitted with 3 mm glass panes with putty and
nails and provided with best quality 4 Nos. 75 mm iron hinges. 2 (two) Nos. best
quality 12 mm dia 250 mm and 150 long iron tower and socket bolts, nickel plated
handles, 225 mm long catch hooks or hinged cleats, buffer blocks and finished by
sand papering for all floors etc. complete and accepted by the Engineer. (All sizes of
wood are finished).
12.14 Seasoning of timber in a recognized mechanical timber seasoning plant up to a cum Tk. 16,203.00
moisture content of 12% - 16% by weight as measured by a electric moisture meter
or any other moisture measuring device etc. complete in all respect including
loading, unloading, carriage at both ends accepted by the Engineer.
12.15.1 Supplying, fitting and fixing steel glazed window shutter for all floors with frames as sqm Tk. 5,572.00
per design having 25 x 25 x 5 mm angle section for Chowkat and shutters and 50 x
25 x 5 mm T- section used for vertical member and 25 x 5 mm F.I. bar for making
box (combining with angle) and 25 x 19 x 5 mm Tee used for glass divider etc.
including all cost of charges for welding, riveting etc. supplying all essential fittings,
like iron hinges, plate handle, pin-stopper, adjustable cleat and clamps, fitting and
fixing the frame including. supplying, fitting, fixing 3 mm glass panes by pucca putty
and making necessary holes in walls and R.C.C works and necessary fitting with
C.C. (1:2:4) and mending good the damages including. all cost of carriage, workshop
charges, electricity, and labour for fittings, fixing, curing etc. all complete and
accepted by the Engineer.
12.15.2 Supplying, fitting and fixing M.S. door shutter made with 1.5” x 1.5” x ¼” angle outer sqm Tk. 5,828.00
frame, inner member 1” x ¼” F.I. bar, cladding with 16 BWG M.S. sheet, hinged with
2” x 2” x ¼” M.S. angle Chowkat.
12.16 Supplying, fitting and fixing steel glazed window shutter for all floors with frames as
per design having 19 x 19 x 19 x 3 mm Z-section in frame and 19 x 3 mm F.I. bar for
making T-section for horizontal dividers of shutters and 25 x 3 mm F.I. bar for middle
vertical members of frame including all cost of charges for fabrication and
manufacture by welding riveting etc. supplying all essential fittings like 2 Nos.
stopper, handle, 150 mm long 3 Nos. adjustable cleats, iron pins, hinges, 150 mm
long 4 Nos. clamps, for fitting frame including supplying, fitting, fixing 3 mm glass
panes by pucca putty and making necessary holes in brick and R.C.C. wall or
member as necessary filling with C.C. (1:2:4) and mending good the damages
including all cost of carriage, electricity, workshop charges and labour in fitting, fixing
etc. all complete as per drawing and design and accepted by the Engineer.
12.16.1 With provision for fan-light (total wt of grill without glass panes is min 28.13 kg for sqm Tk. 3,549.00
15 sft)
12.16.2 Without provision for fan-light (total wt of grill without glass panes is min 24.84 kg sqm Tk. 3,304.00
for 15 sft)
12.17 Manufacturing, supplying fitting and fixing of fixed glazed frame for all floors with sqm Tk. 3,156.00
outer member of 19 x 19 x 19 x 3 mm Z-section and vertical and horizontal dividers
of 19 x 19 x 3 mm T-section including all cost of fabrication and welding, supplying
and fixing of 19 x 19 x 3 mm angle clamps of 150 mm length (with one end
bifurcated) of required Nos, with the frame, fixing the frame in wall with (1:2:4)
cement concrete in the hole for clamp after making necessary grooves, supplying
and fixing of 3 mm glass panes with pucca putty, mending good all damages,
painting iron face with two coats of synthetic enamel paint over a coat of anti-
corrosive priming to approved colour and quality etc. cost of electricity, workshop
charges, carriage etc. all complete as per drawing and accepted by the Engineer.
[Rate is excluding the cost of painting](Scope of work of this item is in staircase and
over partition wall etc.)
PWD SoR 2014 for Civil Works 116
12.18 Supplying, fitting and fixing 25 mm thick wooden double leaf fly proof wire mesh
window shutter for all floors with 75 x 25 mm vertical and horizontal style and sash
bar of 38 x 25 mm section provided with 24 B.W.G. G.I wire mesh netting of 20 mesh
fitted and fixed with shutter by 12 x 12 mm wooden bit, brass screws, nails etc.
including supply of all necessary fittings such as 2 Nos. 150 mm long brass tower
and socket bolt of best quality 4 Nos. 75 mm brass hinges, heavy type 2 Nos. 150
mm long catch hook and 100 mm long brass handle 2 Nos. including fitting and fixing
the same in position with frame with supply of necessary screws and nails etc.
complete and accepted by the Engineer. (All sizes of wood are finished)
12.19 Supplying, fitting and fixing of well matured louver shutter having 75.50mm x 38mm sqm Tk. 14,259.00
size all around frame and inner horizontal wooden louver blade 65mm x 20mm
spaced @ 38mm c/c, fixed with frame in grooves including cost of nails, handle,
tower bolt, screws (brass fitting) etc. all complete in all respect as per drawing and
direction of the Engineer in charge.
12.20 Supplying, fitting and fixing 3" X 3/4" Chittagong Teak wood moulding bit as per rm Tk. 1,090.00
design etc. all complete approved and accepted by the Engineer.
12.21 Extra cost for using brass/ SS fittings in place of iron fittings in doors & windows
for all floors (super quality local).
12.22 Supplying, fitting and fixing of made in hydraulic door closer (big size) including all each Tk. 2,521.00
necessary tools and accessories etc. all complete approved and accepted by the
Engineer.
12.23.1 Supplying, fitting and fixing MORTICE door lock approved and accepted by the each Tk. 1,620.00
Engineer.
12.23.2 Supplying, fitting and fixing Rim/ round door lock approved and accepted by the each Tk. 962.00
Engineer.
12.24 Supplying, fitting and fixing of best quality magnetic door shock absorber including each Tk. 272.00
all necessary tools and accessories etc. all complete approved and accepted by the
Engineer
12.25 Supplying, fitting and fixing best quality heavy type 19 mm dia and to 300 mm long each Tk. 403.00
brass hasp bolt including cutting grooves in door shutter and frames, screws etc. all
complete approved and accepted by the Engineer.
13.1 Supplying, fitting and fixing window grills made of 16 mm dia M.S. rod @ 100 mm sqm Tk. 2,161.00
c/c fitted with 3 (three) Nos. horizontal M.S. flat bar (38 x 6 mm) including fabrication,
welding, riveting, cost of electricity, workshop charges, carriage, fixing with pre-
placed clamps in walls/RCC member for all floors etc. complete and accepted by the
Engineer. (Total weight per sqm should be approx. 22.8 kg and add or deduct @ Tk.
35.00 for each kg excess or less respectively)
Supplying, fitting and fixing window grills of any design made of mild steel section
13.2 sqm Tk. 1,545.00
approx. 20 x 3 mm) with outer frame of approx 25 x 6 mm) F.I. bar fabricating,
welding, cost of electricity, workshop charges, carriage, fixing with pre-placed clamps
in walls or RCC member, all necessary tools and plants etc complete for all floors
and accepted by the Engineer. (Total weight per sqm should be approx 11.0 kg. and
add or deduct @ Tk. 140 for each kg. excess or less respectively)
13.3 Supplying, fitting and fixing window grills of any design made with approx 20 x 5 mm sqm Tk. 1,640.00
F.I. bar as inner and outer section; including fabricating, welding cost of electricity
and tools and plants etc. complete for all floors accepted by the Engineer.
(Total weight per sqm should be min 12 kg. and add or deduct. @ Tk. 136 for each
kg. excess or less respectively)
13.3.1 Supplying, fitting and fixing window grills of any design made with approx 20 x 5 mm Tk. 1,515.00
F.I. bar as inner members but no outer frame; including fabricating, welding cost of
electricity and tools and plants etc. complete for all floors accepted by the Engineer.
(Total weight per sqm should be approx 10 kg. and add or deduct. @ Tk. 152 for
each kg. excess or less respectively)
13.4.1 Supplying, fitting, fixing window grills of any design made with approx 25 x 6 mm F.I. sqm Tk. 2,262.94
bar as both outer and inner section; including fabrication, welding, cost of electricity
workshop charges, carriage, cutting grooves, mending good the damages, tools and
plants etc. complete for all floors accepted by the Engineer. (Total weight per sqm
should be approx 21 kg. and add or deduct @ Tk. 113 for each kg. excess or less
respectively)
13.4.1.1 Supplying, fitting, fixing window grills of any design made with approx 25 x 6 mm F.I. Tk. 2,041.00
bar as inner section but no outer frame; including fabrication, welding, cost of
electricity workshop charges, carriage, cutting grooves, mending good the damages,
tools and plants etc. complete for all floors accepted by the Engineer. (Total weight
per sqm should be approx 18 kg. and add or deduct @ Tk. 108 for each kg. excess
or less respectively)
13.4.2 Supplying, fitting and fixing window grill made of M.S. section approx 25 x 6mm outer sqm Tk. 1,747.85
frame and approx 20 x 5mm inner member as per drawing and design approved and
accepted by the Engineer. (Total weight per sqm should be min 14 kg. and add or
deduct @ Tk. 125 for each kg. excess or less respectively)
13.5.1 Supplying, fitting and fixing window grill made of approx12mm x 12mm M.S. solid bar sqm Tk. 2,416.00
140mm c/c with outer frame of approx 38 x 6mm F.I. bar as per design approved and
accepted by the Engineer.
13.5.2 Supplying, fitting and fixing window grill made of approx 10mm x 10mm M.S. solid sqm Tk. 2,159.00
bar 140mm c/c with outer frame of approx 38 x 6mm F.I. bar as per design approved
and accepted by the Engineer.
PWD SoR 2014 for Civil Works 118
13.6 Supplying, fitting and fixing window grills made of mild steel section 25 mm x 3 sqm Tk. 1,629.00
mm including fabrication, welding, cost of electricity, workshop charges, carriage,
fixing with pre-placed clamps in walls or RCC member, all necessary tools and plants
etc complete for all floors and accepted by the Engineer.
(Total weight per sqm should be min 0.81 kg. and add or deduct @ Tk. 59.00 for
each kg. excess or less respectively)
13.7 Supplying, fitting and fixing veranda grill made of 10 mm dia M.S. rods provided sqm Tk. 2,080.00
75 mm c/c in any position both ways as per design with outside frame 25 x 25 x 6
mm M.S. angle including fabricating welding in each point painting 2 coats of
synthetic enamel paint over a coat of anti-corrosive priming including cost of
electricity, tools and plants, workshop charges, carriage of the same including cutting
groves in the R.C.C. or brick work, mending good the damages with C.C. (1:2:4) etc.
complete for all floors accepted by the Engineer. [Rate is excluding the cost of
painting]
(Total weight per sqm should be min 57.68 kg. and add or deduct @ Tk. 35.00 for
each kg. excess or less respectively)
13.8 Supplying, fitting and fixing and fixing verandah grills made of 3/8” dia M.S. rod sqm Tk. 2,353.00
placed @ 3” c/c both ways fitted with outer frame of M.S. angle 1” x 1” x ¼” as per
drawing and approved and accepted by the Engineer.
14.1 Supplying fitting and fixing of Aluminium swing door with spandrel as per the U.S.
Architectural Aluminium Manufacturer’s Association (AAMA) standard specification
having 1.8 mm thick wall frame size 101.60 mm. 44.45 mm. 83.21 mm). 2.33 mm
thick shutter size (54 mm, 46 mm), 0.99 mm thick door glass bit (size 16.54 mm.
14.49 mm 0.115 kg/m), 2.5 mm thick clousure section (size 101.60 mm, 42.93 mm
1.2 mm), 106.60 mm clousure cover (0.45 kg/m), 4 mm thick floor bottom (size
101.60 mm. 12.70 mm 1 kg/m), 1.8 mm thick shutter bottom (size 82.6 mm, 43.99
mm, 0.60 kg/m), 1.8 mm thick shutter top (size 51 mm, 43.99 mm, 1.88 kg/m) and
2.3 mm to 4.01 mm thick handle (size 101.60 mm, 38.10 mm, 25.40 mm short, 1.35
kg/m) section of all aluminum members will be anodized to aluminium bronze/silver
colour with a coat not less than 15 micrones in thickness and density of 4 mg per
square cm etc. including all accessories like swing door clousure, swing door lock,
swing door mohiar, labour charge, fabrication, fitting fixing in position, carriage and
electricity charge keeping provision for fitting 5 mm thick glass including neoprene
sealant etc. complete in all respect as per drawing and accepted by the Engineer.
(Total weight min 23 kg/m2)
14.2 Supplying fitting and fixing of Aluminium swing door as per the U.S. Architectural
Aluminium Manufacturer’s Association (AAMA) standard specification having 1.8 mm
thick wall frame size 101.60 mm. 44.45 mm. 83.21 mm). 2.33 mm thick shutter size
(54 mm, 46 mm), 0.99 mm thick door glass bit (size 16.54 mm. 14.49 mm 0.115
kg/m), 2.5 mm thick clousure section (size 101.60 mm, 42.93 mm 1.2 mm), 106.60
mm clousure cover (0.45 kg/m), 4 mm thick floor bottom (size 101.60 mm. 12.70 mm
1 kg/m), 1.8 mm thick shutter bottom (size 82.6 mm, 43.99 mm, 0.60 kg/m), 1.8 mm
thick shutter top (size 51 mm, 43.99 mm, 1.88 kg/m) and 2.3 mm to 4.01 mm thick
handle (size 101.60 mm, 38.10 mm, 25.40 mm short, 1.35 kg/m) section of all
aluminum members will be anodized to aluminium bronze/silver colour with a coat
not less than 15 micrones in thickness and density of 4 mg per square cm etc.
including all accessories like swing door clousure, swing door lock, swing door
mohiar, labour charge, fabrication, fitting fixing in position, carriage and electricity
charge keeping provision for fitting 5 mm thick glass including neoprene sealant etc.
complete in all respect as per drawing and accepted by the Engineer.
(Total weight min 23 kg/m2)
14.3 Supplying, fitting and fixing of Aluminium composite swing doors with fixed
partition as per the U. S. Architectural Aluminium Manufacturer’s Association
(AAMA) standard specification having 1.5 mm thick wall frame (size101.60, 44.45
mm, 0.86 kg/m), 1.8 mm thick shutter side (size 54 mm, 46 mm, 1.2 kg/m ), 1 mm
thick door glass bit (size 16.54 mm, 14. 49 mm, 0.115 kg/m), 1.8 mm thick closure
section (size 101.54 mm, 42.93 mm, 1.20 kg/m), 1.5 thick closure cover (101.60
mm, 0.45 kg/m), 4 mm thick floor bottom (size 101.60 mm, 12.70 mm, 1 kg/m), 1.8
mm thick shutter bottom (size 86.60 mm, 43.99 mm , 0.60 kg/m), 1.8 mm thick
shutter top (size 51 mm, 43.99 mm, 1.88 kg/m) 2.3mm to 4.01mm thick handle
(short) (size 101.60 mm, 38.10 mm, 25.40 mm, 1.35 kg/m), 1.5 mm thick top and
side (size 101.60 mm, 44.45 mm, 1.3 kg/m), 1.50 mm thick bottom (size 101.35 mm,
44.45 mm, 1.10 kg/m), 1.50 mm thick bottom cover (44.32 mm, 19.61mm, 0.392
kg/m), 1.50 mm thick grouve cover size 83.21 mm, 16.00 mm, 0.57 kg/m), 0.99 mm
thick fixed glass protector (size 39.09 mm, 14.81 mm, 0.188 kg/m), 0.99 mm thick
fixed glass protector bit (size 15.75 mm, 14.81 mm, 0.13 kg/m) section of all
aluminium members will be anodized to aluminium bronze/silver colour with a coat
not less 15 microns in thickness and density of 4 mg per square cm etc. (Total
weight min 69.699 kg) keeping provision for 5mm of glass panes with cost
including all accessories like swing door clouser, swing door lock , swing door
mohair, flush bolt , bolts and nuts including sealants, labour charge for fitting , fixing
by angles, screws, mohiar, washer, machinery, cost of fabrication, making the
grooves, mending good the damages, electricity etc. complete in all respect as per
drawing and accepted by the Engineer.
14.4 Supplying, fitting and fixing of Aluminium sliding doors as per the U.S. Architectural
Aluminium Manufacturer’s Association (AAMA) standard specification having 1.2 mm
thick outer bottom (size 75.50 mm, 17.79 mm, 0.528 kg/m), 1.2 mm thick outer top
(size 75.50 mm, 26.80 mm, 0.78 kg/m) 1.2 mm thick shutter top (size 33 mm, 26.80
mm, 0.536 kg/m), 1.2 mm shutter bottom (size 60 mm, 24 mm, 0.736 kg/m), 1.2 mm
thick outer side(size 75.50 mm, 19.90 mm, 0.616 kg/m) 1.5 mm thick shutter lock
(size 49.20 mm, 26.20 mm, 0.661 kg/m), 1.2 mm thick inter lock (size 34.40 mm,
32.10 mm, 0.665 kg/m), 1.2 mm thick shutter divider (size 31.75 mm, 0.535 kg/m)
sections all aluminium members (Total weight 14.789 kg) will be anodized to
aluminium bronze/silver colour with a coat not less than 15 microns in thickness and
density of 4 mg per square cm etc. including all accessories like handle, sliding
door key lock , sliding door wheel, sliding door mohiar, sliding door neoprene, bolts
and nuts including sealants, keeping provision for fitting 5mm thick glass including
labour charge for fitting of accessories, making grooves and mending good
damages, carriage, and electricity complete in all respect as per drawing and
accepted by the Engineer. Size up to: 2100 mm x 2100 mm
14.5 Supplying, fitting and fixing of Aluminium sliding doors as per the U.S. Architectural
Aluminium Manufacturer’s Association (AAMA) standard specification having 1.2 m
mm thick outer bottom (size 75.50 mm, 17.79 mm, 0.528 kg/m), 1.2 mm thick outer
top (size 75. 50 mm, 26.80 mm 0.78 kg/m), 1.2 mm thick shutter top (size 33 mm,
26.80 mm, 0.536 kg/m), 1.2 mm thick shutter bottom (size 60 mm, 24 mm, 0.736
kg/m), 1.2 mm thick side (size 75.50 mm, 19.90 mm, 0.616 kg/m), 1.2 mm thick
sliding fixed side (31 mm, 26 mm , 0.422 kg/m) 1.2 mm thick shutter lock (size 49.20
mm , 26. 20 mm , 0.661 kg/m), 1.2 mm thick inter lock (size 34.40 mm, 32.10 mm,
0.665 kg/m) 1.2 mm thick shutter divider (size 31.75 mm, 0.535 kg/m) and 1.4 mm to
1.5 mm thick spandrel (7.14 mm, 0.70 kg/m) sections all aluminium members (total
weight 19.72 kg) will be anodized to aluminium bronze/silver colour with a coat not
less than 15 microns in thickness and density of 4 mg per square cm etc. including
all accessories like sliding door key lock, sliding door whee , sliding door mohiar,
sliding door neoprene, bolts and nuts including sealants, keeping provision for fitting
5mm thick glass including labour charge for fitting of accessories, making grooves
and mending good damages, carriage, and electricity complete in all respect as per
drawing and accepted by the Engineer. Size up to: 1800 mm x 2100 mm
14.6 Supplying, fitting and fixing of Aluminium sliding window as per the U.S.
Architectural Aluminium Manufacturer’s Association (AAMA) standard specification
having 1.2 mm thick outer bottom (size 75.50 mm, 32mm), 1.2 mm thick outer top
(size 75.50 mm, 16.80 mm), 1.2 mm thick shutter top (size 33 mm.26.80, 22 mm),
1.2 mm thick shutter bottom (size 60mm, 24.40 mm), 1.2 mm thick outer side (size
75.50 mm,19.90 mm), 1.2 mm thick sliding fixed side (size 31 mm, 26 mm),1.2 mm
thick shutter lock (size 49.20 mm 26.20 mm) and 1.2 mm thick inter lock (size 34.40
mm, 32.10 mm) sections all aluminium members (total weight kg/sqm) will be
anodized to aluminium bronze/silver colour with a coat not less than 15 micron in
thickness and density of 4 mg per square cm etc. including all accessories like
sliding door key lock, sliding door wheel, sliding door mohiar, sliding door neoprene,
bolts and nuts including sealants, keeping provision for fitting 5 mm thick glass
including labour charge for fitting of accessories, making grooves and mending good
damages, carriage, and electricity complete in all respect as per drawing and
accepted by the Engineer.
14.6.1 Size up to: 1500 mm x 1400 mm. (total weight minimum 9.081 kg)
14.6.2 Size up to: 900 mm x 1400 mm (total weight minimum 7.409 kg)
14.7 Supplying, fitting and fixing of Aluminium sliding composite window with
mosquito mesh as per the U.S. Architectural Aluminium Manufacturer’s Association
(AAMA) standard specification having 1.2 mm thick outer bottom (size 95.00 mm, 38
mm, 0.870 kg/m), 1.2 mm thick outer top (size 95.00 mm, 28.50 mm, 0.97kg/m), 1.2
mm thick shutter top (size 33 mm, 26.80 mm, 22 mm, 0.536 kg/m), 1.2 mm thick
shutter bottom (size 60 mm, 24.40 mm, 0.736 kg/m), 1.2 mm thick outer side (size
95.00 mm, 19.50 mm, 0.738 kg/m), 1.2 mm thick shutter lock (size 49.20 mm, 26.2
mm, 0.661 kg/m), 1.2 mm thick shutter lock (size 34.40 mm, 32.10 mm, 0.665 kg/m),
1.2 mm thick mesh section (size 42.20 mm, 13.20 mm 0.460 kg/m), all aluminium
members (total weight 12.79 kg) will be anodized to aluminium bronze/silver colour
with a coat not less than 15 micron in thickness and density of 4 mg per square cm
etc. including all accessories like sliding door key lock, sliding door wheel, sliding
door mohiar, sliding door neoprene, bolts and nuts including sealants, keeping
provision for fitting fiber mesh including labour charge for fitting of accessories,
making grooves and mending good damages, carriage, and electricity complete in
all respect as per drawing and accepted by the Engineer.
14.8 Supplying, fitting and fixing of Aluminium fixed composite window as per the U.S.
Architectural Aluminium Manufacturer’s Association (AAMA) standard specification
having 1.2 mm thick outer bottom (size 75.50 mm, 32 mm, 0.695 kg/m), 1.2 mm thick
outer top (size 75.50mm, 26.80 mm, 0.78 kg/m), 1.2 mm thick shutter top (size 33
mm, 26.80 mm, 0.536 kg/m), 1.25 mm thick shutter bottom (size 60 mm, 24.40 mm,
0.736 kg/m), 1.2 mm thick outer side (size 75.50 mm, 19.90 mm, 0.616 kg/m), 1.2
mm thick sliding fixed side (size 31 mm, 26 mm, 0.422 kg/m), 1.2 mm thick shutter
lock (size 49.20 mm, 26.20 mm, 0.661 kg/m), 1.2 mm thick inter lock (size 34.40 mm,
32.10 mm 0.665 kg/m) 1.2 mm thick bottom cover (size 37.78 mm, 31.78 mm, 0.313
kg/m), 1.2 mm thick grouve cover (76.20 mm, 38.10 mm, 0.912 kg/m), 1.2 mm thick
grouve cover ( size 57.15 mm, 15.80 mm, 0.452 kg/m) and 1.2 mm thick top and side
(size 76.20 mm, 38.10 mm, 0.3 kg/m) sections all aluminium members (total weight
12.297 kg) will be anodized aluminium bronze/silver colour with a coat not less than
15 micron in thickness and density of 4 mg per square cm etc. including all
accessories like sliding door key lock, sliding door wheel, sliding door mohiar, sliding
door neoprene, bolts and nuts including sealants, keeping provision for fitting 5 mm
thick glass including labour charge for fitting of accessories, making grooves and
mending good damages, carriage, and electricity complete in all respect as per
drawing and accepted by the Engineer. Size up to: 1500mm x 2100 mm.
14.9 Supplying, fitting and fixing of Aluminium top hung/casement windows as per the
U.S. Architectural Aluminium Manufacturer’s Association (AAMA) standard
specification having 1.2 mm thick casement outer (size 38.86 mm, 36.36 mm,
0.395kg/m), 1.9 mm thick casement shutter (size 47.62 mm, 28.57 mm, 0.692 kg/m),
and 1.245 mm thick shutter glass clip (size 15.87 mm, 27 mm, 0.188 kg/m) sections
of all aluminium members will (total weight 7.584 kg) be anodized to aluminium
bronze/silver colour with a coat not less than 15 micron in thickness and density of 4
mg per square cm etc. including all accessories 4-bar hinge, casement handle, bolts
and nuts keeping provision for fitting 5 mm thick glass including labour charge for
fitting of accessories, making grooves and mending good damages, carriage, and
electricity complete in all respect as per drawing and accepted by the Engineer.
14.10
Supplying fitting and fixing of Aluminium corrugated curtain wall as per the U.S.
Architectural Aluminium Manufacturer’s Association (AAMA) standard specification
having 1.2 mm thick bottom cover (size 37.78 mm 31.78 mm, 0.313 kg/m), 1.2 mm
thick grouve cover (size 76.20 m 38.10 mm, 0.912 kg/m), 1.2 mm thick grouve cover
(size 57.15 mm, 15.80 mm 0.45 kg/m), 1.2mm thick top and side (size 76.2 mm,
57.15 mm, 0.153 kg/m) and 1.8 mm thick spandrel (7.14 mm, 0.70 kg/m) sections of
all aluminium members will be anodized to aluminium bronze/silver colour with a coat
not less than 15 micron in thickness and density of 4 mg square cm etc. including all
accessories like rivet, screws fixed neoprene etc. complete in all respect as per
drawing and accepted by the Engineer.
PWD SoR 2014 for Civil Works 124
14.11 Supplying fitting and fixing of Aluminium fixed fan light as per the U.S. Architectural
Aluminium Manufacturer’s Association (AAMA) standard specification mm, 0.313
kg/m) 1.2 mm thick bottom cover (size 76.2 mm, 38.10 mm, 0.76 kg/m) and 2.5 mm
thick grouve cover section (size 57.15mm, 15.80 mm, 0.425 kg/m) and 1.2 thick top
and side section (76.20 mm, 16 mm, 38.10 mm, 0.961 kg/m) fixed with above
mentioned frames and all aluminium members (Total weight 5.365kg) will be
anodized to aluminium bronze/silver colour with a coat not less than 15 micron in
thickness and density of 4 mg per square cm etc. including all accessories,
neoprene, sealant, nut and bolt etc. complete in all respect as per drawing and
accepted by the Engineer.
14.12 Supplying fitting and fixing of Aluminium fixed louver as per the U.S. Architectural
Aluminium Manufacturer’s Association (AAMA) standard specification having 1.2mm
thick wall frame (size 76.20 mm, 38.10 mm, 0.707 kg/m), 5 mm thick louver section
(size 55.02 mm, 37.39 mm, 0.22kg/m) and 2.50 mm thick louver outer section (size
39.67 mm, 15.06 mm, 0.265 kg/m) and inner inclined aluminium louver section fixed
with above mentioned frame and all aluminium members (total weight 7.992 kg) will
be anodized to aluminium bronze/silver colour with a coat not less than 15 micron in
thickness and density of 4 mg per square cm etc. including all accessories,
neoprene, sealant, nuts and bolts etc. complete in all respect as per drawing and
accepted by the Engineer.
14.13 Supplying, fitting, fixing of Aluminium sliding fly proof Netting shutter as per the sqm Tk. 2,069.00
U.S. Architectural Aluminium Manufacturer’s Association (AAMA) standard
specification having 1.2mm thick 38mm x 18mm aluminium outer frame, 1.2mm thick
38mm x 12mmmosquito net shutter frame (mesh section).All aluminium members
(total weight 12.79 kg) will be anodized to aluminium SS/ bronze/silver colour with a
coat not less than 15 micron in thickness and density of 4 mg per square cm etc.
including all accessories like wheel, sealent, rubber, bolts and nuts keeping provision
for fitting fiber mesh including labour charge for fitting of accessories, making
grooves and mending good damages, carriage, and electricity complete in all
respect as per drawing and accepted by the Engineer.
14.14 Supplying, fitting and fixing in Aluminium door frames, windows, partitions and
curtain wall distortion free glass of approved quality and shade including cost of
fitting fixing all necessary accessories etc. complete in all respect as per drawing and
accepted by the Engineer.
14.15 Supplying, fabrication and Installation of Approved colour (4 mm thick) Aluminium sqm Tk. 5,994.00
composite panel (Alucobond/Alcopanel/Alpolic) as per US Architectural Aluminium
Manufacturer's Association (AAMA) in column, beam and wall surface providing with
44 x 44 x 1.5 mm aluminum section including supply of necessary hardwares,
consumables, scaffolding etc. fitted with necessary accessories like rivet, screw,
Rowel bolt etc. all complete in all respect as per drawing and direction of the
Engineer in charge.
14.16 Supplying, fitting and fixing of aluminium curtain wall with aluminium top sqm Tk. 8,238.00
hung/casement windows as per the US Architectural aluminium Manufacturer's
Association (AAMA) Standard Specification having 100 mm , 50mm, 2mm curtain
wall sub-mullim outer and inner frame, 15 mm thick casement outer frame (size
38.86 mm 36.6mm), 1.9 mm thick casement shutter (size 47.62mm, 28.57mm,) 1.2
mm thick shutter glass strips, all aluminium member will be powder coated with coal
not less than 1.5 micron in thickness including all accessories 4 bar hinge casement
handle, 50 m x 50mm x 6m aluminium angle, steel rowel bolt, screws , rivets norton
tape masking tape, structural sealant, gum bracket rod etc. all complete in all respect
as per drawing and direction of the Engineer in charge.
14.17 Supplying, fitting and fixing of aluminium curtain wall and aluminium top sqm Tk. 6,901.00
hung/basement windows ad per the US Architectural aluminium Manufacturer's
Association (AAMA) Standard Specification having 50 mm , 50mm, 2mm curtain wall
sub-mullim outer and inner frame, 15 mm thick casement outer frame (size 38.86
mm 36.6mm), 1.9 mm thick casement shutter (size 47.62mm, 28.57mm,) 1.2 mm
thick shutter glass strips, all aluminium member will be powder coated with coal not
less than 1.5 micron in thickness including all accessories 4 bar hinge casement
handle, 50 m x 50mm x 6m aluminium angle, steel rowel bolt, screws , rivets norton
tape masking tape, structural sealant, gum bracket rod etc. all complete in all respect
as per drawing and direction of the Engineer in charge.
15.1 Minimum 12 mm thick cement sand (F.M. 1.2) plaster (1:4) with fresh cement to sqm Tk. 214.00
wall both inner-and outer surface, finishing the corner and edges including washing
of sand cleaning the surface, scaffolding and curing at least for 7 days, cost of water,
electricity and other charges etc. all complete in all respect as per drawing and
accepted by the Engineer. (Cement: CEM-II/A-M). Ground floor.
15.2 Minimum 12 mm thick cement sand (F.M. 1.2) plaster with neat cement finishing sqm Tk. 246.00
to plinth wall (1:4) with cement up to 150 mm below ground level with neat cement
finishing including washing of sand, finishing the edges and corners and curing at
least for 7 days, cost of water, electricity and other charges etc. all complete in all
respect as per drawing and accepted by the Engineer. (Cement: CEM-II/A-M)
Ground floor.
15.3 Minimum 12 mm thick cement sand (F.M. 1.2) plaster with neat cement finishing sqm Tk. 263.00
to dado (1:4) with cement up to 150 mm with neat cement finishing including
washing of sand, finishing the edges and corners and curing at least for 7 days, cost
of water, electricity and other charges etc. all complete in all respect as per drawing
and accepted by the Engineer. (Cement: CEM-II/A-M). Ground floor.
15.4 Minimum 12 mm thick cement sand (F.M. 1.2) plaster (1:6) having with fresh sqm Tk. 198.00
cement to wall both inner-and outer surface, finishing the corner and edges including
washing of sand cleaning the surface, scaffolding and curing at least for 7 days, cost
of water, electricity and other charges etc. all complete in all respect as per drawing
and accepted by the Engineer.(Cement: CEM-II/A-M)Ground floor.
15.5 Minimum 6 mm thick cement sand (F.M. 1.2) plaster (1:4) with fresh cement to sqm Tk. 186.00
ceiling R.C.C. columns, beams, surface of stair case, sunshades, cornices, railings,
drop wall, louvers, fins and finishing the corners and edges including washing of
sand cleaning the surface, scaffolding and curing at least for 7 days, cost of water,
electricity and other charges etc. all complete in all respect as per drawing and
accepted by the Engineer. (Cement: CEM-II/A-M). Ground floor.
15.6 Minimum 6 mm thick cement sand (F.M. 1.2) plaster (1:3) with fresh cement to sqm Tk. 191.00
ceiling R.C.C. columns, beams, surface of stair case, sunshades, cornices, railings,
drop wall, louvers, fins and finishing the corners and edges including washing of
sand cleaning the surface, scaffolding and curing at least for 7 days, cost of water,
electricity and other charges etc. all complete in all respect as per drawing and
accepted by the Engineer. (Cement: CEM-II/A-M). Ground floor.
15.7 Flush pointing to brick wall with cement sand (F.M. 1.2) mortar (1:2) with cement sqm Tk. 117.00
including raking out the joints, and necessary scaffolding curing at least for 7 days,
cost of water, electricity and other charges etc. all complete in all respect as per
drawing and accepted by the Engineer. (Cement: CEM-II/A-M). Ground floor.
15.8 Rule pointing to brick wall with cement sand (F.M. 1.2) mortar (1:2) with fresh sqm Tk. 149.00
cement and raking out the joints, scaffolding, curing at least for 7 days, cost of water,
electricity and other charges etc. all complete in all respect as per drawing and
accepted by the Engineer. (Cement: CEM-II/A-M). Ground floor.
PWD SoR 2014 for Civil Works 127
15.9 Raised or tack pointing work to brick wall with cement sand (F.M. 1.2) mortar sqm Tk. 359.00
(1:2) with fresh cement minimum 12 x 20 mm in size including raking out the joints
and necessary scaffolding, curing at least for 7 days, cleaning each and every brick,
cutting the bricks with pumic stone where necessary etc. all complete in all floors,
cost of water, electricity and other charges etc. all complete in all respect as per
drawing and accepted by the Engineer. (Cement: CEM-II/A-M) Ground floor.
15.10 Providing drip course or Nosing at the edge of sunshade or cornice with cement rm Tk. 91.00
sand (F.M. 1.2) mortar (1:2) with fresh cement including scaffolding, curing at least
for 7 days, cost of water, electricity and other charges etc. all complete in all respect
as per drawing and accepted by the Engineer.(Cement: CEM-II/A-M)Ground floor.
15.11.1 Making groove in plaster on outside wall upto 50mm X 6mm size including rm Tk. 18.00
scaffolding, curing etc. complete as per drawing and accepted by the Engineer.
15.11.2 Making groove in plaster on outside wall upto 38mm X 6mm size including rm Tk. 27.00
scaffolding, curing etc. complete as per drawing and accepted by the Engineer..
15.12 Extra rate for plaster and all types of pointing shall be incorporated in the estimate
15.12.1 Add for each additional floor up to 5th floor. sqm Tk. 11.00
15.12.2 Add for each additional floor from 6th floor to 9th floor sqm Tk. 17.00
15.12.3 Add for each additional floor above 9th floor sqm Tk. 22.00
15.13 Average 100 mm thick finished lime terracing with 20 mm down graded first class cum Tk. 12,015.00
brick chips (Khoa), surki from 1st class bricks and min lime content 500kg per
2.83cubic meter (stone lime brought at site, not being powdered in open air and to be
slaked in presence of engineer-in-charge and to be measured in volume three days
after slaking for using in the mix) in the proportion 7:2:2 (brick chips : surki : lime)
including preparation of the mix on the ground by making a suitable platform under
proper polythene cover. Cutting the mix twice daily with limewater (1:10) at least for 7
days until the mix attain desirable consistency. Laying the mix in proper slope,
beating the same with standard ‘koppa’ for minimum 7 days to gain maximum
consolidation, making ghoondy and neat finishing with lime Surki mortar (1:2) and
curing for 21 days providing polythene cover after each day work and cleaning etc.
complete in all respect accepted by the Engineer.
15.14 Pre-cast ventilators of minimum 25 mm thick of any design with cement sand sqm Tk. 1,777.00
(F.M.1.2) mortar (1:4) fitted and fixed in position, finished with cement sand (F.M.
1.2) plaster (1:6) including necessary scaffolding and curing, in all floors accepted by
the Engineer. (Cement: CEM-II/A-M)
15.15 75 x 75 mm cornice of brick masonry in cement sand (F.M. 1.2) mortar (1:6) having rm Tk. 174.00
minimum 12 mm thick cement sand (F.M. 1.2) plaster (1:6) including scaffolding and
curing at least for 7 days in all floors accepted by the Engineer. (Cement: CEM-II/A-
M)
15.16 Supplying, fitting, fixing of broken and sharp glass 19 mm to 32 mm height, av. 19 sqm Tk. 211.00
mm width placed at a distance approximately 25 mm center to center spacing,
embedding the same to 12 mm to 19 mm thick cement plaster with neat cement
finishing including necessary scaffolding approved and accepted by the
Engineer.(Cement: CEM-II/A-M)
16.1 White washing by three coats, lime mixture prepared at least 12 hours before use, sqm. Tk. 18.00
slacking stone lime, supply of gums, blue, stirring thoroughly, removing the floating
materials from the mixer, surface cleaning to free from all foreign materials before
application of each coat, applying one vertical and one horizontal wash for each coat
and successive coat is to be applied after drying up of previous coat including hair
brass, providing necessary scaffolding and cleaning plinth, floors, doors, windows,
portions and ventilators by washing, rubbing, oiling if necessary after white wash for
all floors including cost of water, electricity and other charges etc. complete in all
respect in all floors and accepted by the Engineer.
16.2 Colour wash with yellow orchard/any other colour pigment by two coats over a sqm. Tk. 20.00
prime coat of white wash, lime mixture prepared at least 12 hours before use,
slacking stone lime, supply of gums, blue, stirring thoroughly, removing the floating
materials from the mixer, surface cleaning to free from all foreign materials before
application of each coat, applying one vertical and one horizontal wash for each coat
and successive coat is to be applied after drying up of previous coat including hair
brass, providing necessary scaffolding and cleaning plinth, floors, doors, windows,
portions and ventilators by washing, rubbing, oiling if necessary after white wash for
all floors including cost of water, electricity and other charges etc. complete in all
respect in all floors and accepted by the Engineer.
16.3 Cement Paint of approved quality and colour delivered from authorized local agent sqm. Tk. 128.00
of the manufacturer in a sealed container, made from water based powder mixed
with water (1:1), applying first coat, curing the same after six hours for 24 hours,
second coat applied and curing the same for 7 (seven) days etc, taking care and
cleaning the surface fully from grease, oily substances, old paints, lime wash,
fungus, algae etc., sand papering the surface before applying 1st and 2nd coat,
complete including cost of electricity, water and other changes etc. complete in all
floors and accepted by the Engineer.
16.4 On exterior surface applying as per manufacturer instructions 3 coat of weather coat sqm. Tk. 189.00
of approved quality and colour delivered from authorized local agent of the
manufacturer in a sealed container complete in all respect in all floors and accepted
by the Engineer.
16.5 On exposed brick surface applying as per manufacturer instructions in 3 coats sqm. Tk. 193.00
silicon based water repellent of approved quality delivered from authorized local
agent of the manufacturer in a sealed container etc. complete in all respect in all
floors and accepted by the Engineer.
16.6 Painting to door and window frames and shutters in two coats with approved best sqm. Tk. 183.00
quality and colour of synthetic enamel paint delivered from authorized local agent
of the manufacturer in a sealed container, having highly water resistant, high
bondibilty, flexible, using specific brand thinner applied by brass/roller/spray over a
coat of priming elapsing time for drying including surface cleaning from dust, oil or
dirt, smoothening, finishing and polishing with sand paper and necessary tools,
scaffolding, testing charges etc. all complete in all floors approved and accepted by
the Engineer.
PWD SoR 2014 for Civil Works 129
16.7 Approved best quality and colour synthetic polyvinyl distemper delivered from sqm. Tk. 147.00
authorized local agent of the manufacturer in a sealed container, applying to wall and
ceiling in 2 coats over a coat of brand specified primer or sealer elapsing specified
time for drying/ recoating matt finish including cleaning and sand papering making
the surface free from loose and flaky materials, dirt, grease, wax, polish, scraping all
chalked and scaled materials, applying the paint by brush/roller and necessary
scaffolding etc. all complete in all floors accepted by the Engineer.
16.8.1 Plastic emulsion paint of approved best quality and colour delivered from sqm. Tk. 159.00
authorized local agent of the manufacturer in a sealed container, applying to wall and
ceiling in two coats over a coat of brand specified primer or sealer elapsing
specified time for drying or recoating including cleaning drying, making free from dirt,
grease, wax, removing all chalked and scaled materials, fungus, mending good the
surface defects, sand papering the surface and necessary scaffolding, spreading by
brush/ roller/spray etc. all complete in all floors accepted by the Engineer.
16.8.2 Plastic emulsion paint of approved best quality and colour delivered from sqm. Tk. 221.00
authorized local agent of the manufacturer in a sealed container, applying to wall and
ceiling in two coats over lime putty of specified brand applied on primer or sealer
elapsing specified time for drying/recoating including cleaning drying, making free
from dirt, grease, wax, removing all chalked and scaled materials, fungus, mending
good the surface defects, sand papering the surface and necessary scaffolding,
spreading by brush/ roller/spray etc. all complete in all floors accepted by the
Engineer.
Lime putty to be applied as per manufacturer instructions approved and accepted by
the Engineer.
16.9.1 Acrylic emulsion painting (silky finish) of approved best quality and colour sqm. Tk. 162.00
delivered from authorized local agent of the manufacturer in a sealed container,
applying to wall and ceiling in two coats over a coat of brand specified primer or
sealer including cleaning, drying, making free from loose and flaky materials, dirt,
grease, wax, removing all chalked and scaled materials, fungus, elapsing specified
time for drying, re-coating, flaking paints, mending good the surface defects, sand
papering the surface, smoothing by putty and necessary scaffolding, testing charges,
applied by brush/roller/spray etc. all complete in all floors accepted by the Engineer.
16.9.2 Acrylic emulsion painting (silky finish) of approved best quality and colour sqm. Tk. 218.00
delivered from authorized local agent of the manufacturer in a sealed container,
applying to wall and ceiling in two coats over lime putty of specified brand applied
on primer or sealer elapsing specified time for drying/recoating including cleaning
drying, making free from dirt, grease, wax, removing all chalked and scaled
materials, fungus, mending good the surface defects, sand papering the surface and
necessary scaffolding, spreading by brush/ roller/spray etc. all complete in all floors
accepted by the Engineer.
16.10 omitted
16.11 omitted
16.12 Textured paint of approved best quality and colour delivered from authorized local sqm. Tk. 578.00
agent of the manufacturer in a sealed container, applying to wall and ceiling
including cleaning, drying, making free from dirt, grease, wax, removing all chalked
and scaled materials, fungus if required must be treated with fungicidal solution,
flaking paints, mending good the surface defects, sand preparing the surface and
necessary scaffolding, applied by brush/roller/spray etc. all complete in all floors
accepted by the Engineer.
PWD SoR 2014 for Civil Works 130
16.13 Chlorinated rubber paint of approved quality and colour delivered from authorized sqm. Tk. 306.00
local agent of the manufacturer in a sealed container, applying to concrete surfaces
and walls in three coats elapsing specified time for drying and re-coating including
cleaning, drying, making free from dirt, grease, wax, removing all chalked and scaled
materials, fungus (if required must be treated with fungicidal solution) flaking paints,
washing the surface with soap water/caustic soda, mending good the surface
defects, smoothening the surface by putty sand papering the surface and necessary
scaffolding, applied by brush/roller/spray etc. all complete in all floors and accepted
by the Engineer.
16.14 French polishing to door and window frames and shutters three coats over a coat sqm. Tk. 293.00
of priming including putty, cleaning finishing and polishing with sand paper etc. all
complete in all floors accepted by the Engineer.
16.15 Wood varnishing of approved quality and colour delivered from authorized local
agent of the manufacturer in a sealed container using brand specified thinner to door
and window frame and shutter in three coats, applied with brush including cleaning
oil, grease, dirt, making dry, sand papering, if required washing with weak detergent
solution, stripping out the colour straps, finishing the surface, etc. all complete in all
floors accepted by the Engineer.
17.1 Constructing surface drain of 300 mm clear width and depth up to 300 mm in rm. Tk. 1,167.00
brick masonry with 125 mm thick check wall in cement sand (F.M. 1.2) mortar (1:6)
over av. 75 mm thick cement concrete base (1:3:6) over one layer of brick flat soling.
The surface having minimum 12 mm thick cement sand (F.M. 1.2) plaster (1:3) and
neat cement finishing with cement curing at least for 7 days including excavation in
all kinds of soil, back filling with fine sand (F.M. 0.8), consolidating and dressing, cost
of water, electricity, other charges etc. complete and accepted by the Engineer.
(Cement: CEM-II/A-M)
17.2 Constructing surface drain of 600 mm (av.) depth and 225 mm clear width at rm. Tk. 2,340.00
the bottom and 525 mm at the top having 125 mm thick cement concrete (1:2:4) curb
up to 300 mm from the bottom over one layer of polythene on top brick flat soling and
the side slopes of the remaining 300 mm height provided with 125 mm thick first
class brick work in cement mortar (1:6) including minimum 12 mm thick cement sand
(F.M. 1.2) plaster (1:3) including neat cement finishing the surfaces and back of the
drain up to 150 mm below ground level with fresh cement (conforming to BDS 232)
curing at least for 7 days including excavation of all kinds of soil, back filling with fine
sand (F.M. 0.8) consolidating and dressing, including cost of water, electricity, other
charges etc. complete and accepted by the Engineer. (Cement: CEM-II/A-M)
17.3 Providing apron with 50 mm thick cement concrete (1:2:4) with cement, coarse sand sqm. Tk. 832.00
and picked jhama chips including breaking chips and one layer brick flat soling at
bottom with first class or picked jhama bricks including cutting earth for preparation
of bed and filling the interstices with local sand (F.M. 0.8) including finishing,
dressing, curing at least for 7 days etc. all complete, including cost of water,
electricity, other charges accepted by the Engineer. (Cement: CEM-II/A-M)
17.4.1 Supplying, laying, fitting fixing best quality 225 mm dia (internal) machine made rm. Tk. 911.00
R.C.C. pipe over 100 mm thick cement concrete (1:3:6) at base and sides including
single brick flat soling and gasket with cement mortar (1:4) joints, cutting and filling
trenches up to required depth including excavation of soil etc. all complete in all
respects as per type plan and accepted by the Engineer (average depth of trench is
3'-6"). (Cement: CEM-II/A-M)
17.4.2 do- with 300 mm dia (internal) R.C.C. pipe. rm. Tk. 1,188.00
17.5 Supplying, laying and fitting-fixing 900 mm dia RCC pipe of approved quality and rm. Tk. 9,661.00
accepted by the Engineer. [Rate is excluding cost for excavation, back-fill, materials
for back-fill and bedding]
18.1.1 Supplying, fitting and fixing plain particle board complying unit wt 499 to sqm. Tk. 2,674.00
550kg/m3 , bending strength 0.35N/mm2 , max swelling 8% , moisture content not
more than 10% , for ceiling of 12 mm thick with best quality and well seasoned
Garjan wood frame of section 75 x 38 mm at 600 x 600 mm in grid suspended from
ceiling or roof or beam by 12 SWG double ply G.I. wire fixed to the ceiling by rowel
plug, screws, hooks, nails etc. maintaining straight lines and desired finished level at
bottom face with vertical strut as required including cutting holes in slabs or beams
by electric drill machine and mending good the damages, if any, during execution of
the work including cost and carriage of all materials, accessories, labour for
installation, electricity charge, scaffolding, screws, nails etc. including. painting 2
coats over a coat of priming with best quality and approved colour synthetic enamel
as per item no 16.6 of this schedule of etc. all complete as per drawing design and
accepted by the Engineer. (All sizes of wood are finished)
18.1.2 Supplying, fitting and fixing plain particle board as in itme 18.11 for ceiling of 12 sqm. Tk. 2,860.00
mm for auditorium and other type of tall structures beyond 4 m up to 8 m,
which do not cover the above item [Item No. 153(a)]. Description of item is the same
as in item No. 153(a) above.
18.1.3 Supplying, fitting and fixing of ceiling with 12 mm thick melamine board laminated sqm. Tk. 1,522.00
by mechanical hot press with a milk white PVC membrane in aluminium frame
suspended from ceiling.
18.2.1 Supplying, fitting and fixing gypsum board ceiling of 9 mm thick board laminated by sqm. Tk. 1,692.00
mechanical hot press with a milk white PVC membrane with Aluminium T-bar frame
in natural anodized finish at 600 x 600 mm in grid suspended from ceiling by 12
SWG double ply wire fixed to the ceiling by rowel plug, screws, hooks, nails etc.
maintaining straight lines and desired finished level a bottom face with vertical
wooden strut as required including making holes in slabs, or beams by electric drill
machine and mending good the damages, if any, during execution of the work
including cost of all materials, electricity, accessories, scaffoldings, labour for
installation, screws, nails, etc. all complete as per drawing, design and accepted by
the Engineer.
18.2.2 - do - with 12 mm thick veneered board ceiling. sqm. Tk. 1,962.00
18.2.3 Supplying, fitting and fixing of 9 mm thick perforated gypsum board false ceiling sqm. Tk. 1,751.00
with aluminium T bar frame in natural anodized frame at 600 mm x 600 mm grid
suspended from ceiling by 12 SWG double ply G.I. Wire
18.3.1 Supplying, fitting and fixing 12 mm thick Burma Teak (BT) Veneered board in sqm. Tk. 3,379.00
walling with best quality and well seasoned Garjan wood frame of section 75 x 38
mm at 600 x 600 mm in grid, fitted and fixed to wall by plugs, nails, screws etc.
including treatment of inner surface with termite and damp proofing agent
maintaining leveled and finished exposed faces including. making holes in wall and
mending good the damages. If any, during execution of the work including. cost and
carriage of all materials, electricity, accessories, labour for installation, scaffolding,
screws, nails etc. including French polishing 3 coats over a coat of priming as per
item No. 137 of the schedule etc. all complete as per design, approved sample and
accepted by the Engineer.
18.3.2 - do - 12 mm thick particle board walling sqm. Tk. 2,360.00
19.1.1 Manufacturing, supplying, fitting and fixing collapsible gate of any design and sqm. Tk. 3,531.00
shape made of 3/4" x 3/4" x 1/8" channel placed @ 112 mm c/c vertically and
connecting the same with each other by 20 x 3 mm M.S flat bar scissors 525 mm/
600 mm long provided in 3 rows including cutting the different M.S. members to
required sizes, fabricating, welding, riveting with required size rivets, providing
required size wheels, pulling handles on both sides, suitable locking arrangement,
electrodes, grease and finally placing the same in position in between 2 (two) Nos.
50 x 50 x 6 mm M.S. Tee rail made by welding 2 Nos. 50 x 6 mm M.S. flat bar fitted
and fixed at top and bottom with R.C.C. lintel/roof slab, floors and side wall with
required Nos. 150 mm to 225 mm long 38 x 6 mm M.S. flat bar clamps one end
welded with the gate member and the other end bifurcated and embedded in C.C. at
the respective point including cutting holes and mending good the damages by
pouring concrete (1:2:4) into the holes and finishing, etc complete, painting 2 (two)
coats with approved best quality synthetic enamel paint over a coat of anticorrosive
painting, both end carriage, including greasing, electrodes, curing etc. complete as
per drawing and design and accepted by the Engineer.
(Rate is excluding the cost of paint).
19.1.2 -do- -do- Collapsible gate made of 3/4" x 3/4" x 1/8" M.S. angle as vertical member sqm. Tk. 4,045.00
and 3/4" x 1/8" F.I bar as scissors.
19.1.3 -do- -do- Collapsible gate made of 1" x 1" x 1/8" M.S. angle as vertical member and sqm. Tk. 4,876.00
1" x 1/8" F.I bar as scissors.
19.2.1 Supplying, fitting, fixing, and installation of ordinary type M.S. gate (double leaf) of sqm. Tk. 5,756.00
any design and shape with 38 x 38 x 6 mm M.S. Angle outer frame having 16 mm
dia M.S. rod placed vertically @ 75 mm c/c. at bottom part and top part (arrows) and
also placed horizontally at bottom for interconnection of 16 mm dia M.S. rod placed
vertically as per design, the top part covered with 18 BWG M.S. sheet and fixed with
4 Nos. 38 x 6 mm F.I. bars placed diagonally and 4 Nos. 38 x 6 mm F.I. bars placed
horizontally and vertically all passing through the center, providing locking
arrangements on 3 mm thick M.S. plate one for main gate and one for minimum 300
x 1025 mm pocket gate with 38 x 38 x 6 mm M.S. angle and 16 mm dia M.S. rod
placed vertically @ 75 mm c/c, providing 38 x 38 x 6 mm M.S. angle clamps fitted
and fixed with the outer frame of the main gate, the clamp being embedded in R.C.C.
or R.C.C. core pillar with cement concrete (1:2:4) in masonry including cutting holes
and mending good the damages, finishing, curing etc. including riveting, welding as
and where necessary, painting two coats with approved quality of synthetic enamel
paint over a coat of priming of anti-corrosive paint etc. all complete as per drawing,
design and accepted by the Engineer. (Rate is excluding the cost of paint).
19.2.2 Manufacturing, supplying and fitting-fixing security door with 7/8” dia M.S. rod and sqm. Tk. 10,070.00
outer frame with 2” x 2” x ¼” M.S. angle complete as per drawing and accepted by
the Engineer.
PWD SoR 2014 for Civil Works 134
19.3 Supplying, fitting, fixing, and installation of ordinary type M.S. security gate of any sqm. Tk. 5,007.00
design and shape with 50 x 50 x 6 mm M.S. angle outer frame and two 50 x 50 x 6
mm angle placed diagonally having 22 mm dia M.S. rod placed vertically @ 115 mm
c/c. and also 38 x 6 mm F.I placed horizontally, the bottom part covered with 3 mm
thick M.S. sheet providing locking arrangements on 3 mm thick M.S. plate providing
heavy type clamps fitted and fixed with the outer frame of the main gate, the clamp
being embedded in R.C.C. or R.C. core pillar with cement concrete (1:2:4) in
masonry including cutting holes and mending good the damages, finishing, curing
etc. including fabrication, riveting, welding as and where necessary, etc. all complete
as per drawing, design and accepted by the Engineer.
19.4 Supplying, fitting, fixing and installation ordinary type M.S. gate (double leaf) of sqm. Tk. 7,991.00
any design and shape with 38 x 38 x 6 mm M.S. angle box (made by welding 2 Nos.
38 x 38 x 6 mm angle) outer frame having 25 x 50 x 25 x 5 mm M.S. channel (made
by welding 2 Nos. of angle) placed part diagonally after cutting and shaping as per
requirement part horizontally @ 75 mm C/C the two part of each leaf being
separated by a vertical member of 38 x 38 x 6 M.S. box and welded the each ends of
diagonal and horizontal members properly with the box frame as per architectural
drawing providing full locking arrangement on 3 mm thick M.S. plates providing 38 x
38 x 6 mm M.S. angle clamps, fitting fixing with the outer frame of the gate the
clamp being embedded in R.C.C. pillars with cement concrete (1:2:4) including.
cutting holes and mending good the damages, finishing, curing and where necessary
painting two coats with approved quality of synthetic enamel paint over a coat of
priming of anticorrosive paint etc. all complete including making and providing 50 x 6
mm M.S. rail and 38 mm wheel for smooth movement of the gate etc. all complete as
per drawing, design and accepted by the Engineer. [Rate is excluding the cost of
painting]
19.5 Manufacturing, supplying, fitting and fixing G.I. pipe gate of any design and shape sqm. Tk. 9,307.00
having 38 mm dia G.I. pipe outer frame and 19 mm dia. G.I. pipe vertical member
placed @ 75 mm c/c by welding at top and bottom of G.I. pipe frame, cutting the
pipes in proper shape and size including making semicircular band at the corners of
the outer frame without damaging the pipe, covering 50% of the gate area with 18
BWG M.S. sheet, providing also two extra horizontal 38 mm dia G.I. pipes welded
with vertical post, providing 6 Nos. huskle domney with R.C.C. or R.C.C core pillar
with cement concrete (1:2:4) in masonry including cutting holes, mending the
damages, making provision for minimum 0.61 m x 1.4 m pocket gate having its outer
frame and inner vertical members made with 19 mm dia G.I. pipe including
necessary locking arrangements. Painting the gate with 2 (two) coats of synthetic
enamel paint over a coat of anti-corrosive priming, welding as and where necessary
including necessary locking arrangement and providing 2 Nos. 16 mm M.S. socket
bolts etc. all complete as per design and drawing and accepted by the Engineer.
[Rate is excluding the cost of painting]
PWD SoR 2014 for Civil Works 135
19.6 Supplying, fitting and fixing of rolling shutter of any design and shape made of 24 sqm. Tk. 5,300.00
SWG G.P. sheet unit minimum 69 mm width having 10 mm and 12 mm dia circular
folding at ends, rolled in machine, locked together properly to form rolling shutter, top
of the shutter to be fitted with circular spring box made of 22 BWG sheet, containing
best quality spring made in China, nutted with 38 mm G.I. pipe at one end and the
other end nutted to shutter including fitting the G.I. pipe again with 375 x 300 x 6 mm
pankha at ends with side guide channel (side channel consist of 50 x 100 x 6 mm
M.S. plate with 2 x 19 x 3 mm F.I. bar, middle channel consist of 2 x 150 mm x 6 mm
M.S. plate with 2 x19 mm x 6 mm fixed to wall or column with clamps embedded in
R.C.C. part by cement concrete (1:2:4) including cutting holes (minimum 3 x 25 mm
x6 mm) mending the damages, finishing, curing, bottom end of shutter fitted to folded
G.P. sheet (min 125 mm width in two layers), which is again fitted to 25 x 25 x 3 mm
angle, providing handle with F.I. bar 25 x 6 mm and locking arrangement in both
sides, painting two coats with approved colour and brand of synthetic enamel paint
over a coat of priming etc. complete in all respect accepted by the Engineer. [Rate is
excluding the cost of painting]
19.7 Manufacturing, Supplying, fitting, fixing of ordinary type M.S. folding gate with sqm. Tk. 4,865.00
12mm x 12mm MS square solid bar and 25 mm x 25mm x 6 mm MS Angle box
frame including fabrication, welding, cost of electricity, workshop charges, carriage,
cutting grooves, mending good the damages, finishing, curing etc. including
fabrication, riveting, welding as and where necessary, etc. all complete as per
drawing, design and accepted by the Engineer.
20.1 Manufacturing, supplying, fitting and fixing stair railing of any standard height of any sqm Tk. 3,273.00
design and shape with square box (2 Nos. in each tread) made by thorough
welding of 2 Nos. 19 x 19 x 3 mm M.S. angle to provide hand-rail, engraving each
box 150 mm in the concrete by 50 x 50 x 6 mm anchor plate at base welding 38 mm
x 6 mm F.I. bar inclined plain with the top of the box to fit in the grooved wooden rail
by necessary screws including cutting grooves in concrete, mending good the
damages with cement concrete (1:2:4), applying first class polish to hand rail, 2 (two)
coats of synthetic enamel paint of approved quality over a prime coat etc. finished in
all respect for all floors and accepted by the Engineer.(Exposed area of railing will be
considered for measurement, rate is excluding cost of hand-rail and cost of painting).
20.2 Manufacturing, supplying, fitting and fixing stair railing of standard height of any sqm Tk. 6,471.00
design and shape with square box (2 No. box in each tread) made by thorough
welding of 2 Nos. 25 x 25 x 5 mm M.S. angle, engraving each box 150 mm in the
concrete by 50 x 50 x 6 mm anchor plate at base welding 50 x 50 x 6 mm F.I. bar in
inclined plain with the top of the box fit in the grooved wooden rail and 2 Nos. 225 x
25 mm finished section of wooden strip fitted and fixed at mid height of railing at both
side of M.S. angle box in inclined plain parallel to the hand rail etc. fitted and fixed by
necessary screws, nails including cutting grooves in concrete mending good the
damages with cement concrete (1:2:4) applying 1st class French polish to wooden
hand rail and inclined wooden strip and painting to F.I bar and square box with 2
(two) coats of synthetic enamel paint of approved quality and colour over a prime
coat etc. complete in all respect for all floors and accepted by the Engineer.
(Exposed area of railing will be considered for measurement, rate is excluding cost of
polishing and painting)
20.3 Supplying, fitting and fixing 12 mm dia G.I pipe stair railing of any standard height
of any design and shape with 50 x 50 x 6 mm M.S. plate at the base of 12 mm dia
G.I. Pipe and fitted and fixed by welding. Placing the pipes vertically @ 125 mm c/c
(1 Nos. in each steps) 150 mm embedded into the R.C.C tread of stair case after
cutting grooves and mending good the damages with C.C. and providing 38 x 6 mm
F.I. bar on the top of G.I. pipe to provide wooden/G.I. pipe hand rail of any design
including polishing painting etc. all complete and accepted by the Engineer.
(Exposed area of railing will be considered for measurement, rate is excluding the
cost of pain, wood for railing)
20.3.1 With the provision of hand rail of size: 150 x 62 mm (finished) sqm Tk. 1,932.00
20.3.2 With the provision of hand rail of size: 112 x 62 mm (finished) sqm Tk. 2,479.00
20.4 Supplying, fitting and fixing stainless steel (SS) stair railing of standard height with sqm Tk. 7,008.00
2 mm thick 2.5” dia pipe for hand-rail as per drawing and accepted by the Engineer.
20.5.1 Supplying, fitting and fixing 12 mm dia G.I pipe stair railing of any standard height sqm Tk. 3,467.00
of any design and shape with 50 x 50 x 6 mm M.S. plate at the base of 12 mm dia
G.I. Pipe and fitted and fixed by welding. Placing the pipes vertically @ 125 mm c/c
(1 Nos. in each steps) 150 mm embedded into the R.C.C tread of stair case after
cutting grooves and mending good the damages with C.C. and providing 38 x 6 mm
F.I. bar on the top of G.I. pipe to provide wooden/G.I. pipe hand rail of any design
including polishing painting etc. all complete and accepted by the Engineer.(Exposed
area of railing will be considered for measurement, rate is excluding the cost of pain,
wood for railing)
PWD SoR 2014 for Civil Works 137
20.5.2 - do - with 50 mm dia G.I. Pipe hand rail sqm Tk. 3,972.00
20.6 Supplying, fitting and fixing verandah railing with 2mm thick 50 mm, 25 mm and 20 sqm Tk. 11,391.00
mm diameter stainless steel pipes as per approved design and accepted by the
Engineer.
20.7 Providing noising to the Nose of tread of stair including supplying 3 Nos. of 75 mm
long 12 mm x 3 mm F.I. bar clamp with bifurcated ends in each treads including
fitting and fixing with the angle by welding including fitting and fixing the angle by
cutting grooves in R.C.C, fixing and finishing and the same with C.C. (1:2:4) etc. cost
of electricity all complete and accepted by the Engineer.
20.7.1 Providing 1.5" x 1.5" x 1/4" M.S. angle to the nosing of steps of staircase rm Tk. 376.00
20.7.2 Providing nosing 1.25" x 1.25" x 1/4" M.S. angle to the nosing of steps of stair case. rm Tk. 325.00
20.7.3 Providing 1" x 1" x 1/4" size M.S. angle to the nosing of stair case. rm Tk. 276.00
20.7.4 Providing 1.5" x 1.5" x 1/4" brass angle to the nosing of steps of stair case rm Tk. 1,206.00
21.1 Supplying, fitting and fixing steel grill fencing in boundary wall of any design and sqm Tk. 1,929.00
shape with 31 x 6 mm F.I. bar @ 150 mm c/c placed vertically after cutting as per
required measurement. Welding the said F.I. bar with 2 Nos. horizontal 30 x 6 mm
F.I. bar placed one at top and another at bottom including embedding/fixing the
horizontal F.I. bar in position including cutting grooves in wall up to 150 mm depth
and mending good the damages with C.C. (1:2:4) finished with two coats of painting
with synthetic enamel paint over a coat of anti-corrosive paint etc. complete as per
drawing and design and accepted by the Engineer. (Rate is excluding the cost of
painting)
21.2 Supplying, fitting and fixing steel grill fencing of any design and shape made with sqm Tk. 4,470.00
19 mm x 3 mm tube (angle box made with 2 Nos.19 x 19 x 3 mm angle in by
continuous welding) placed vertically @ 150 mm c/c and welding the said vertical
boxes with two Nos. horizontal 25 x 25 x 6 mm angle box (made with 2 Nos. 25 x 25
x 6 mm angle by welding), placing one at bottom and another at top and again fitted
and fixed by welding the said horizontal tube box (with vertical 38 x 38 x 6 mm angle
box post made with 2 Nos. 38 x 38 x 6 mm angle by welding) provided 1800 mm c/c
including embedding the tube box post in brick R.C.C. pillar or core wall up to 375
mm depth after cutting grooves in wall/pillar including mending good the damages
with C.C. (1:2:4) and finishing, curing, 2 coats of approved synthetic enamel paint
over a coat anti-corrosive paint etc. all complete as per design, drawing and
accepted by the Engineer.(Rate is excluding the cost of painting)
21.3 Manufacturing, supplying, fitting and fixing M.S. grill fencing as per design with sqm Tk. 2,238.00
outer frames having 38 x 38 x 6 mm M.S. angle and inner members having 6 mm dia
M.S. rod placed @ 110 mm c/c diagonally on both direction, welding each cris-cross
end of rod with corners of outer frame including cutting rods and size angles to
required shapes and size and setting the entire fence with the previously installed
tube (angle box) post including thorough and full welding the frame with the angle
box posts, painting 2 coats of synthetic enamel paint over a coat of anti-corrosive
priming etc. all complete as per drawing and accepted by the Engineer.
(Rate is excluding the cost of angle box post and its installation and excluding the
cost of paint)
21.4 Manufacturing, supplying, fitting and fixing M.S. tube (angle box) post (bottom end sqm Tk. 932.00
bifurcated) made by thorough welding of two Nos. 38 x 38 x 6 mm M.S. angle and
vertically placing the post into C.C. or R.C.C. foundation including cutting angle to
required shape and size including covering the top of the post with 6 mm thick M.S.
plate etc. all complete as per drawing. (Rate is excluding the cost of C.C./R.C.C.
foundation and paint)
21.5 Providing barbed wire fencing with R.C.C (1:2:4) pillars @ 2.43 m c/c. and of sqm Tk. 139.00
section 100 mm x 100 mm at top and 150 mm x 150 mm at bottom of 2.13 m total
height (1.37 m above G.L. and 0.76 m below G.L.) including 150 mm thick, 450 mm
square spread footings (pillars reinforced with 4 Nos. 10 mm dia main rod and 6 mm
dia stirrups @ 150 mm c/c, footing reinforced with 5 Nos. 10 mm dia rod both ways)
supplying, fitting and fixing 8 lines of barbed wire horizontally (fixed with the post
through 6 mm dia, rods embedded in to the post) and 2 lines diagonally from post to
post with 12 BWG 2 ply barbed wire, with 4 points barbs @ at least 112 mm c/c
including 6 mm thick (1:4) cement plaster up to 1500 mm length of the pillars etc.
complete and accepted by the Engineer. (Rate is excluding the cost of concrete and
reinforcement which is to be paid as per corresponding items in the schedule)
PWD SoR 2014 for Civil Works 139
21.6 Providing barbed wire fencing with average 100 mm dia best quality local bullah sqm Tk. 240.00
post of 1.98 m total height (1.37 m above G.L. and min. 0.60 m embedded in the
ground) placed at 1800 mm c/c with 9 Nos. horizontal lines and 2 Nos. diagonal lines
of 12 BWG 2 ply barbed wire with 4 points barbs @ at least 112 mm c/c in each way
of 1.8 m including embedded the post tightly in ground and providing a cement
concrete base of 200 x 200 x 300 mm around ballah at E.G.L, stretching the wires
and fixing with the post with the help of minimum 62 mm long G.I. nails including
supply of all materials etc. all complete and accepted by the Engineer.(Rate is
excluding the cost of ballah and its driving/fixing and concrete which is to be paid as
per corresponding items in the schedule)
21.7 Supplying, fitting and fixing 12 BWG barbed wire (2 ply, 4 points) in fencing work sqm Tk. 760.00
@ 150 mm c/c in both horizontally and vertically, supported by 38 x 38 x 6 mm
M.S. angle post (300 mm embedded in R.C.C. or in brick work with a cement
concrete base of 75 x 75 x 300 mm) 600 mm vertical and 450 mm inclined or as per
requirement @ 2.4 m c/c including straightening, binding the joints with 18 BWG wire
making holes in the angle etc. in /c supplying of all necessary materials complete in
all respect and accepted by the Engineer. (Rate is excluding the cost of R.C.C or
brick work or C.C. which is to be paid as per corresponding items in the schedule)
22.1 Supplying, fitting and fixing wooden wedge instead of putty by 12 mm x 12 mm rm Tk. 54.00
(base x height) for fixing glass panes with wooden frame by nails or by any other
approved method including the cost of necessary wood, painting/polishing, nails etc.
and excluding the cost of wooden frame, and painting and 5 mm thick glass panes all
complete and accepted by the Engineer.
22.2 Supplying, fitting and fixing of 20mm dia foreign made aluminium pipe curtain rail rm Tk. 552.00
for door and window including cutting and fitting fixing as per required measurement
and supplying necessary screws, electric drill and rowel plug including charge of
electricity etc. complete and accepted by the Engineer.
22.3 Supplying, fitting and fixing 10mm thick clear tempered glass door including all sqm Tk. 13,075.00
accessories 1 set maintenance auto closed special quality 2 nos clamping device, 1
set locking device, top hinge and handle etc. complete in all respect as per drawing
and direction of the Engineer in Charge.
22.4 Supplying, fitting and fixing 10mm thick clear glass partition with 44mm, 44mm, sqm Tk. 3,238.00
1.5mm aluminium box, protector bit (single), protector bit (double) in/c all accessories
etc. all complete and as per drawing and direction of the Engineer in Charge.
22.5 Supplying, fitting and fixing of C.T wood strip (62 x 25 x 20 mm) for fixing of rm Tk. 646.00
aluminium curtain rails as per design and drawing fitted and fixed in position
including supply of screws, nails, drilling etc. and two coats of French polishing over
a coat of priming etc. all complete and accepted by the Engineer. (Rate is excluding
the cost of polishing and painting etc.)
22.6 Supplying, fitting and fixing vertical Venetian blinds made with glass fiber fabrics sqm Tk. 1,655.00
(foreign made) with supply of all materials (foreign made) such as Head rail
(Aluminium), end cap-set, rod till, sigger (stopper) runner, spacer (link), Handling
cord, ball chain, link chair, cord-weight weight-plate plastic washer, glass fiber
fabrics, and head cap-set etc. all complete and accepted by the Engineer.
22.7 Supplying, fitting and fixing horizontal Venetian blinds 1" width made with sqm Tk. 1,270.00
aluminium foils/ strips (foreign made) with supply of all materials (foreign made) such
as head rail, bottom rail, rod till, head cap, bottom cap, gear box, stick, support and
cap, cord drum and support, bracket, cord lock, cord equalizer, top holder, ladder,
cord, handling cord and aluminium foils etc. all complete and accepted by the
Engineer.
22.8 Supplying, fitting, fixing of steel iron rack made of 50 x 50 x 6.35 mm vertical and sqm Tk. 9,334.00
horizontal angle post, welding 63.5 mm x 6.35 mm F.I. bar placed horizontally as
bracing for the posts, 38 x 6.35 mm cross F.I. bars welded with vertical post, 12.7
mm thick M.S plate welded as cup shape at the bottom of post, supplying and fitting
rivets, charge for wielding, drilling, carrying, cutting, straightening, in required sizes
etc in all respect as per drawing, design and accepted by the Engineer.
PWD SoR 2014 for Civil Works 141
22.9 Supplying fitting, fixing of uPVC plastic door or window frame having specific rm Tk. 248.00
gravity 1.35 - 1.45, and other physical, chemical, thermal, fire resistivity properties
etc. as per BSTI approved manufacturer standards or ASTM, BS/ISO/IS standards
fitted and fixed in brick wall/ R.C.C wall with 6 Nos. GI clamp, 4Nos inner joint GI
clamp, 2 Nos. outer GI joint clamp, 16 Nos. rivet making necessary grooves and
mending good the damages, finishing, curing, carriage etc complete in all respect
accepted by the Engineer.
22.10 Supplying, fitting, fixing of uPVC hollow or solid plastic door shutter having
specific gravity 1.35 - 1.45, thickness 1.7 mm-2.2 mm, and other physical, chemical,
thermal, fire resistivity properties etc. as per BSTI approved manufacturer standards
or ASTM, BS/ISO/IS standards of different sizes fitted fixed with uPVC plastic door
frame weighing 5.82 kg/m2 with at least 3 Nos. SS hinges by min 64 Nos. Ø 3.17 mm
and 3.97 mm 12.7 mm long rivets, 12 Nos. 25.4 mm SS screws, Ø 9.38 mm, 150
mm long SS tower bolts 2 Nos., 146 mm SS handle by rivet 2 Nos., G.I inner joint
234.95 mm x 127 mm clamp, 76.2 mm x 57.15 mm, 25 mm dia 1 no SS haspbolt,
special type round lock, carrying the same to the site and local carriage etc.
complete in all respect accepted by the Engineer
22.10.1 760 mm x 1980 mm uPVC plastic shutter (hollow). each Tk. 3,259.00
22.10.2 760 mm x 2130 mm uPVC plastic shutter (solid). each Tk. 3,369.00
22.10.3 910 mm x 2130 mm uPVC plastic shutter (hollow). each Tk. 3,557.00
22.10.4 990 mm x 2130 mm uPVC plastic shutter (solid). each Tk. 3,683.00
22.11 Supplying, fitting, fixing uPVC plastic or glass partition in plastic frame fabricated
by 70 x 50 x 2 mm T and 50 x 40 x 2 mm / 50 x 30 x 2 mm L-sections, providing
partition with 156 x 25 mm uPVC hollow section having wall thickness 2.5 mm /
partition with 5 mm thick glass. Physical, chemical, thermal, fire resistivity properties
etc of the materials as per BSTI approved manufacturer standards or ASTM,
BS/ISO/IS standards, fitted and fixed in brick wall or R.C.C wall with 6 Nos. GI
clamp, 4 Nos. inner joint GI clamp, 2 Nos. outer GI joint clamp, 16 Nos. rivet making
necessary grooves and mending good the damages, finishing, curing, carriage etc
complete in all respect and accepted by the Engineer.
22.12 Supplying, fitting, fixing of uPVC Profile for door, window and fixed partition rm Tk. 439.00
frames applications having specific gravity 1.36-1.43, and other physical, chemical,
thermal, fire resistivity properties etc. as per BSTI approved manufacturer standards
or ASTM, BS/ISO/IS standards including all accessories fittings with 6 Nos. steel
clamps complete in all respect as per drawing and accepted by the Engineer.
22.13 Supplying, fitting, fixing swing door shutter made of low density free foam (LDFF)
sheet having standard size 4' x 8'. Physical properties: density: 0.55-0.68 g/cm3,
weighing 1.3 kg/sft, providing new sash (4"), sliding glass bead, rubber, screws, 3"
hinges 4 Nos., 4" tower bolt 2 Nos., 6" handle 2 Nos. etc. including all accessories
complete in all respect as per drawing and accepted by the Engineer.
22.13.1 6'-6" x 2'- 6" size 8 mm thick uPVC swing door shutter each Tk. 8,762.00
22.13.2 7'-0" x 2'- 6" size 8 mm thick uPVC swing door shutter each Tk. 9,027.00
PWD SoR 2014 for Civil Works 142
22.13.3 7'-0" x 3-0 size 8 mm thick uPVC swing door shutter each Tk. 9,293.00
22.14 Supplying fitting fixing of plastic wall paneling with 3 mm sheet, weighing 0.188 sqm Tk. 1,119.00
kg/sft fitted and mending good the damages, carriage to the site including glass
bead, partition frame, rubber, 5 mm clear glass fitted and fixed with screws, steel
clamp accepted by the Engineer.
22.15 Supplying, fitting, fixing of uPVC Profile fixed partition with 5 mm clear glass, sqm Tk. 3,129.00
weighing 1.032 kg/sft fitted and mending good the damages, carriage etc. complete
in all respect accepted by the Engineer
22.16 Supplying, fitting, fixing of uPVC profile sliding window having gross weighing 1.3
kg/sft (including glass) fitted and mending good the damages, carries etc complete in
all respect accepted by the Engineer.
22.16.1 uPVC sliding window with 5 mm glass 4'-0" x 4'-0" sqm Tk. 4,374.00
22.16.2 uPVC sliding window without glass 4'-0" x 4'-0" sqm Tk. 3,388.00
22.17 Supplying, fitting, fixing of plastic wood paneling in false ceiling with 6 mm sheet, sqm Tk. 1,147.00
weighing 0.358 kg/sft fitted and mending good the damages, carries etc complete in
all respect accepted by the Engineer
22.18 Supplying, fitting and fixing approved quality 190 mm x 190 mm size glass bricks in sqm Tk. 13,740.00
round stair wall complete in all respect and accepted by the Engineer.
22.19 Supplying, and fitting and fixing 50 mm thick rock or glass wool padding of sqm Tk. 3,509.00
approved quality and accepted by the Engineer.
23.1 Earthwork in excavation of tank of any dimension in all kinds of soil including
cutting up to required depth including bailing out water and throwing on the
embankment, breaking clods, ramming and leveling, dressing in 225 mm layer with
maintaining the side slopes and level of both tank and the embankment as per
design and accepted by the Engineer.
23.1.1 For initial lead of 30 m and lift of 1.5 m cum Tk. 142.00
23.1.2 For each additional lift of 0.3 m beyond 1.5 m and up to 3 m cum Tk. 5.30
23.1.3 For each additional lift of 0.3 m beyond 3 m and up to 4.5 m cum Tk. 7.77
23.1.4 For each additional lift of 0.3 m beyond 4.5 m and up to 6 m cum Tk. 10.24
23.1.5 Extra each additional lead of 0.3 m or part there of beyond initial lead 30 meter cum Tk. 20.84
23.2.1 Bailing out water by 1 cusec diesel operated pump including hire charge of Per hour Tk. 458.00
pump, fuel, operator, spares and maintenance etc. complete.
23.2.2 Bailing out water by 1 cusec electricity operated pump including hire charge of Per hour Tk. 373.00
pump, fuel, operator, spares and maintenance etc. complete
24.1 Earth work in road embankment up to a lift of 1.5 m in all kinds of soil including
cutting and throwing earth in layers not exceeding 150 mm in thickness, breaking
clods up to 40 mm size in each layer, ramming, leveling and dressing as per required
side slope and alignment with earth borrowed from the road side Govt. acquired land
for any leads and maintaining the embankment true to level and side slopes as per
profiles for one year from the date of completion including making dug, bailing,
profiling etc. complete and accepted by the Engineer.
24.1.2 For additional lift of 1 m beyond 1.5 m up to 2.5 m cum Tk. 126.00
24.1.3 For additional lift of 1 m beyond 2.5 m up to 3.5 m cum Tk. 142.00
24.1.4 For additional lift of 1 m beyond 3.5 m up to 4.5 m cum Tk. 158.00
24.1.5 For additional lift of 1 m beyond 4.5 m up to 5.5 m cum Tk. 173.00
24.1.6 For additional lift of 1 m beyond 5.5 m up to 6.5 m cum Tk. 189.00
24.2 Earthwork in box cutting in all types of soil. Removing soil to a safe distance,
maintaining proper alignment, camber and grade including leveling, dressing and
compacting the sub grade as per drawing and accepted by the Engineer
24.3 Creating turf on the side slopes and top of embankment with good quality turf not sqm Tk. 13.00
less than 225 mm square chunk, watering till the grass grown including all leads and
lifts etc. complete and accepted by the Engineer.
24.4 Single layer brick flat soling in road work with first class or picked jhama bricks as sqm Tk. 368.00
per alignment, camber and grade including filling joints with sand (F.M. 0.50) etc.
complete including cost of all materials and accepted by the Engineer.
24.5 Brick on edges pavement in herring bone bond (HBB) with first class or picked sqm Tk. 601.00
jhama bricks as per alignment, camber and grade over 12 mm thick sand cushion
(F.M. 0.50) including filling the joints with the same sand including cost of all
materials and accepted by the Engineer.
24.6 Double brick flat soling in roadwork with first class or picked jhama bricks as per sqm Tk. 744.00
camber and grade and filling the joints with fine sand (F.M. 0.50) and also providing
12 mm thick sand cushion in between the two layers of brick flat soling with the same
quality of sand including cost of all materials and accepted by the Engineer.
24.7 Brick on end edging (75 mm across the road) with first class or picked jhama bricks rm Tk. 93.00
and filling the gaps with fine sand (F.M. 0.50) including cutting trenches, true to level
and grade, removing earth, refilling and ramming the sides properly including cost of
all materials and accepted by the Engineer.
PWD SoR 2014 for Civil Works 145
24.8 Breaking picked jhama, first class bricks or bats including cost of bricks and bats
and stacking in measurable sizes at site accepted by the Engineer
24.9 Labour for compacted water bound Macadam base course with graded metal of cum Tk. 613.00
crushed well burnt, picked jhama or first class bricks and bats having compacted
thickness made as per specifications including local handling and spreading
uniformly to proper grade, camber and super elevation, hand packing, rolling
properly with 8 to 10 ton capacity power driven Road Roller and watering profusely
for compaction of 100% MDD (standard) blinding with sand (F.M. 0.80) @ 12 m3 per
m2 including fuel, lubricants, spares, maintenance, driver etc. all complete and
accepted by the Engineer.
24.10 Providing compacted sub-base base course with well graded metal of crushed well cum Tk. 3,379.00
burnt p.j. / 1st class brick bats and sand (FM 0.8) with mixing proportion 2 : 1 having
compacted thickness made as per specification including local handling, spreading
uniformly to proper grade camber and super elevation, packing rolling properly with 8
to 10 ton capacity power driven road roller and watering properly for compaction of
100% MDD (standard) blinding with sand including cost of fuel, lubricants, spares,
maintenance, driver etc. all complete and accepted by the Engineer in charge.
24.11 50 mm thick compacted premixed bituminous carpeting with 12 mm down well sqm Tk. 1,046.00
graded stone chips having water absorption not greater than 2% flakiness index not
greater than 35 @ 0.64 cum of stone chips mixed with 42 kg of heated bitumen
(bitumen content % by wt. of total is 5.2% to 5.80%) heating at 1350C to 1550C and
spread uniformly over 10 sqm of surface, rolled with 8 to 10 ton Roller compacted
fully in proper grade and camber spreading 0.12 cum sand (F.M.1.50) on 10 sqm
including tools and equipment etc. all complete and accepted by the Engineer.
NB: If Asphalt Plant is used rates will be increased by 25%.
24.12 38 mm thick compacted premixed bituminous carpeting with 10 mm down well sqm Tk. 858.00
graded stone chips having water absorption not greater than 2%, flakiness index
not greater than 35 @ 0.32 cum of stone chips mixed with 22.00 kg of heated
bitumen (bitumen content % by wt. of total is 5.2% to 5.80%), heating at 1350C to
1550C and spread uniformly over 10 sqm of surface rolled with 8 to 10 ton Roller
compacted fully in proper grade and camber and spreading 0.12 cum sand (F.M.
1.50) on 10 sqm surface etc. all complete and accepted by the Engineer.
NB: If Asphalt Plant is used rates will be increased by 25%.
24.13 25 mm thick compacted premixed bituminous carpeting with 10 mm down well sqm Tk. 626.00
graded stone chips having water absorption not greater than 2% flakiness index not
greater than 35 @ 0.32 cum of stone chips mixed with 22.00 kg of heated bitumen
(bitumen content % wt. of total is 5.2% to 5.80%), heating at 1350c to 1550c and
spread uniformly over 10 sqm of surface rolled with 8 to 10 ton Roller compacted
fully in proper grade and camber and spreading 0.12 cum sand (F.M. 1.50) on 10
sqm surface etc. all complete and accepted by the Engineer.
NB: If Asphalt Plant is used rates will be increased by 25%.
PWD SoR 2014 for Civil Works 146
24.14 50 mm thick compacted premixed bituminous carpeting with 12 mm down well sqm Tk. 885.00
graded shingles @ 0.64 cum of shingles mixed with 42 kg of heated bitumen
(bitumen content % by wt. of total is 5.2% to 5.80%) heating at 1350c to 1550c and
spread uniformly over 10 sqm of surface. Rolled with 8 to 10 ton Roller compacted
fully in proper grade and camber spreading 0.12 cum sand (F.M. 1.50) on 10 sqm
etc. all complete and accepted by the Engineer. NB: If Asphalt Plant is used rates will
be increased by 25%.
24.15 38 mm thick compacted premixed bituminous carpeting with 12 mm down well sqm Tk. 737.00
graded shingles @ 0.48 cum of shingles mixed with 30.25 kg of heated bitumen
(bitumen content % by wt. of total is 5.2% to 5.80%), heating at 1350c to 1550c
spread uniformly over 10 sqm of surface rolled with 8 to 10 ton Roller compacted
fully in proper grade and camber and spreading 0.12 cum sand (F.M.-1.50) on 10
sqm surface including necessary tools and equipment etc. all complete and accepted
by the Engineer. NB: If Asphalt Plant is used rates will be increased by 25%.
24.16 25 mm thick compacted premixed bituminous carpeting with 10 mm down sqm Tk. 495.00
graded and well grades shingles @ 0.32 cum of shingles mixed with 20.50 kg of
heated bitumen (bitumen content % by wt. of total is 5.2% to 5.80%), heating at
1350c to 1550c spread uniformly over 10 sqm of surface rolled with 8 to 10 ton Roller
compacted fully in proper grade and camber and spreading 0.12 cum sand
(F.M.1.50) on 10 sqm surface including necessary tools and equipment etc. all
complete and accepted by the Engineer. NB: If Asphalt Plant is used rates will be
increased by 25%.
24.17 Providing tack coat @ 7.32 kg of bitumen per 10 sqm including heating bitumen up sqm Tk. 87.00
to 1760C to 1880C and spreading etc. all complete (cost of bitumen included)
accepted by the Engineer.
24.18 Providing seal coat with 4 cft of Sylhet sand (FM 2.2) mixed with @ 7.32 kg of sqm Tk. 186.00
bitumen per 10 sqm of road surface including supplying and spreading of 0.09 cum
of sand (F.M. 0.80) including heating bitumen up to 176 degree to 190 degree
Celsius and spreading etc. all complete (cost of bitumen included) accepted by the
Engineer.
24.19 Premixed bituminous seal coat with 0.12 cum of pea gravels mixed with 80 kg of sqm Tk. 235.00
bitumen per cum of pea gravels and laid over 10 sqm, road surface, spreading with
proper camber, grade, surface blinding with dry sand (F.M. 2.5) @ 0.09 cum per 10
sqm, rolling the suface with min 8 ton power driven roller etc. all complete and
accepted by the Engineer.
24.20 Providing bitumenous painting with 4.54 kg of bitumin per 10 sqm. of road surface sqm Tk. 104.00
including supplying and spreading of 0.09 cum of sand (FM 1.20) with heating
bitumen upto 176 degree to 196 degree celsius, surface rolling with min 8 ton power
driven roller etc. all complete and accepted by the Engineer.
24.21 Providing painting top of the road surface as road marking in two coats with sqm Tk. 223.00
approved best quality and colour of synthetic approved quality of paint from
authorized local agent of the manufacturer in a sealed container having highly water
resistant, high bondability, flexible, using specific brand thinner applied by brass/
roller or others over a coat of priming elapsing time for drying including surface
cleaning from dust, oil or dirt, smoothening, finishing necessary tools etc. all
complete in approved and accepted by the Engineer.
PWD SoR 2014 for Civil Works 147
24.22 Providing expansion joints across the R.C.C. road pavement with 20 mm gap rm Tk. 317.00
between the adjacent panels. Supplying dowel bars of size 12 mm dia 600 mm long
M.S rod placed at 750 mm c/c. 300 mm of the bar fixed within one slab keeping
remaining portion the bar free within the adjacent slab being inserted in 20 mm dia
300 mm long P.V.C. pipe embedded in the slab, inside of pipe fully greased, filling
the gap between the slabs (with admixture) of hot bitumen and coarse sand (F.M.
2.5) in proportion (2:1) finishing the top with bitumen, spreading coarse sand over the
joint, all complete as per plan, drawing and accepted by the Engineer.
25.1 Labour charge for scraping lawn surface up to 38 mm thick by spade, picking up all sqm Tk. 7.10
sorts of bricks bats, rubbish by suitable tools, removing the same by head load or by
any other means and stacking the same to a safe distance beyond 300 m including
supply of tools and plants etc. all complete and accepted by the Engineer.
25.2 Preparation of ground to make ready for plantation by spading the ground in to a sqm Tk. 15.00
depth of 150 mm to 230 mm beyond 38 mm thick scrapped ground by spade,
breaking earth clods to powder by hammers, picking up all sorts of rubbish,
unwanted grasses by suitable tools, carrying and spreading the surplus earth into
low lying area including supply of tools and plants etc. all complete and accepted by
the Engineer.
25.3 Leveling and dressing of lawn area to proper slope and grade by spading the sqm Tk. 4.70
same up to 150 mm including supplying tools and plants etc. all complete and
accepted by the Engineer.
25.4 Supplying of best and approved quality alluvial loamy silty soil including loading, cum Tk. 567.00
unloading at both ends, properly stacking at site including supply of tools and plants
etc. all complete and accepted by the Engineer.
25.5 Supplying well decomposed cow dung carried by trucks or any other means cum Tk. 1,183.00
including loading, unloading at both ends, stacking the same at site including supply
of tools and plants etc. all complete and accepted by the Engineer.
25.6 Labour charge for spreading the alluvial loamy silty soil from the stacks at site on cum Tk. 115.00
the lawn surface, leveling, dressing the same including supply all necessary tools
and plants etc. all complete and accepted by the Engineer.
25.7 Supplying lawn grass of approved quality by truck or any other means, sorting the sqm Tk. 41.00
grass to proper size, washing the grass, dibbling the grass 6 mm to 50 mm apart,
irrigation of lawn area till the grass grown at least for two months after plantation,
weeding the undesirable grass, mowing the lawn grass by lawn mower up to two
months after plantation, applying urea fertilizer on the lawn surface @ 1 kg per 9.29
sqm including supply of tools and plants etc. all complete and accepted by the
Engineer.
25.8 Labour charge for mixing well decomposed cow dung with alluvial loamy silty cum Tk. 107.00
soil and excavated earth, removing the excess earth to safe distance including
supply of tools and plants etc. all complete and accepted by the Engineer.
25.9 Supplying and providing, fitting, fixing bamboo jafry fencing by best quality muli sqm Tk. 364.00
bamboo split 20mm in width, having 75 mm x 75 mm mesh placed horizontally and
diagonally doing 25 mm framing a square shape in both ways and both sides
tightened with G.I wire fitted with Borrak bamboo post of 100 mm dia and placed
firmly in position at 1800 mm apart including supply of tools and plants, digging hole
and filling back etc. all complete and accepted by the Engineer.
PWD SoR 2014 for Civil Works 149
25.10 Supplying and providing, fitting, fixing muli bamboo tree guard 1200 mm long and each Tk. 481.00
500 mm dia fixing with best quality muli bamboo split 20 mm in size having 75 mm x
75 mm a square holes with 20 mm wide bamboo splits strengthen with 4 Nos. 20 mm
wide bamboo split in both sides tightened with G.I wire fitted with 3 Nos. 63 mm dia
borrak bamboo post of 1800 mm long of which 600 mm will be driven into earth by
digging hole followed by fill back including supply of tools and plants all complete as
per direction of engineer-in-charge.
25.11 Earth work in excavation to make a pit of 600 x 600 x 450 mm (depth) for each Tk. 110.00
plantation, applying cow dung mixing with loamy silty soil and excavated earth,
planting the plants, tightened with 1800 mm long borrak bamboo post with jute rope
including supply of tools and plants all complete and accepted by the Engineer.
25.12 Spading for preparation of flower beds in pits up to 600 mm depth, re-molding, sqm Tk. 364.00
picking up and placing and removing the spaded earth to a safe distance, mixing @
1 cft well decomposed cow dung with 20% loamy silty soil and 6 cft excavated soil
and fill back the pit including supply of tools and plants all complete and accepted by
the Engineer.
25.13 Preparation of hedge beds by excavation of earth up to 300 mm depth filling up the sqm Tk. 183.00
bed by a mixture of cow dung, loamy silty soil, cutted earth @ 1 cft cow dung manure
per 6 cft of cutted earth and 20% loamy silty soil including supply of tools and plant
etc. all complete and accepted by the Engineer.
25.14 Carrying of rubbish, taking up all sorts of bricks, brick-bats and rubbish gravel cum Tk. 111.00
chips, loading and unloading at both ends including supply of tools and plants etc. all
complete and accepted by the Engineer.
25.15 Supply and carrying of 12.20 m long 100 mm dia borrak bamboo at site, loading each Tk. 378.00
and unloading at both end stacking the same at site including supply of tools and
plants etc. all complete and accepted by the Engineer.
25.16 Supply and carrying of 7.62 m long 50 mm to 62.5 mm dia muli bamboo at site, each Tk. 171.00
loading and unloading at both end stacking the same at site including supply of tools
and plants etc. all complete and accepted by the Engineer.
26.1 Supplying, fitting and fixing European type glazed porcelain commode "S" type
465 x 340 x 415 mm in size, approximately 14 kg by weight, plastic seat cover and
preparing the base with cement concrete and with wire mesh or rods, if necessary, in
all floors including making holes wherever required and mending good the damages
and fitting, fixing finishing etc. complete with all necessary fittings and connection
approved and accepted by the Engineer.
26.1.1 Standard
26.2 Supplying, fitting and fixing European type glazed porcelain low-down, capacity 10
liter, 490 x 190 x 350 mm in size, approximately 14 kg by weight, on walls by screws
and F.I. bar clamps, rowel plugs, making holes wherever required and mending good
the damages and fitting, fixing finishing etc. complete with all necessary fittings and
connection approved and accepted by the Engineer.
26.2.1 Standard
26.3 Supplying, fitting and fixing European type glazed porcelain Combi closet, in/c
plastic seat cover, cystern system, preparing the base with cement concrete and with
wire mesh or rods if necessary, in all floors including making holes wherever required
and mending good the damages and fitting, fixing, finishing etc. complete with all
necessary fittings and connection approved and accepted by the Engineer.
26.3.1 Standard
26.3.1.1 BISF White, Item No. 115A/415A, 700 x 410 x 795 mm,31.5 kg each Tk. 7,242.00
26.3.1.2 BISF Coloured Item No. 115A/415A, 700 x 410 x 795 mm,31.5kg each Tk. 7,242.00
26.3.1.3 BISF Special coloured Item No. 115A/415A, 700 x 410 x 795 mm,31.5kg each Tk. 8,679.00
26.3.2 Super
26.3.3 Superior
26.4 Supplying, fitting and fixing European type glazed combi closet,
approx.725x360x840 mm size, approx. 42.7 kg by weight,in/c plastic seat cover,
cystern system, preparing the base with cement concrete and with wire mesh or rods
if necessary, in all floors including making holes wherever required and mending
good the damages and fitting, fixing, finishing complete with all necessary fittings and
connection approved and accepted by the Engineer.( an exclusive item, subject to
approval by not less than SE)
26.5 Supplying, fitting and fixing Bangladesh pattern, long pan with foot-rest, made of
Vitreous China and preparing the base of pan with cement mortar (1:4) and with wire
mesh or rods, if necessary in all floors including making holes wherever required and
mending good the damages and fitting, fixing, finishing etc. complete with all
necessary fittings and connection approved and accepted by the Engineer.
26.5.1 Standard
26.5.2 Super
26.6 Supplying, fitting and fixing Bangladesh pattern long pan, made of Vitreous China
and preparing the base of pan with cement concrete and with wire mesh or rods if
necessary in all floors including making holes wherever required and mending good
the damages and fitting, fixing, finishing etc. complete with all necessary fittings and
connection approved and accepted by the Engineer.
26.6.1 Standard
26.7 Supplying, fitting and fixing plastic low-down including all fittings and accessories each Tk. 2,017.00
26.8 Supplying 280x140x30mm size glazed porcelain foot rest, 1.5 kg by weight each Tk. 174.00
including fitting, fixing in position with cement mortar (1:4) if necessary in all floors
including making holes wherever required and mending good the damages and
fitting, fixing, finishing etc. complete with all necessary fittings and connection
approved and accepted by the Engineer.
26.9 Supplying, fitting and fixing white glazed vitreous W/H Wash Basin including
excluding pedastal, fitting, fixing the same in position with heavy type C.I. Brackets.
30 mm dia PVC waste water pipe with brass coupling (not exceeding 750 mm in
length), basin waste with chain plug including making holes in walls and floors and
fitting with wooden blocks, screws and mending good the damages, finishing etc. all
complete approved and accepted by the Engineer.
26.9.1 Standard
Cabiet Basin
Corner Basin
26.9.1.24 BISF -207 Special Colored 420x370x200, 7.5kg each Tk. 1,921.17
26.10
Supplying, glazed vitreous W/H Wash Basin in/c pedastal approx. size
656x510x845, 26kg by weight including fitting, fixing the same in position with heavy
type C.I. Brackets. 30 mm dia PVC waste water pipe with brass coupling (not
exceeding 750 mm in length). 12mm plastic lead (connection) pipe with brass
coupling, basin waste with chain plug including making holes in walls and floors and
fitting with wooden blocks, screws and mending good the damages, finishing etc. all
complete approved and accepted by the Engineer.
26.10.1 Superior
26.11 Supplying, white glazed vitreous W/H Wash Basin in/c pedastal and fitting, fixing
the same in position with heavy type C.I. brackets, 32 mm dia PVC waste water pipe
with brass coupling (not exceeding 750 mm in length), 32 mm dia C.P. basin waste
with chain plug, bracket including making holes in walls and floors and fitting with
wooden blocks, screws and mending good the damages with cement mortar (1:4),
etc. all complete approved and accepted by the Engineer.
26.11.1 Super
26.12 Supplying, fitting and fixing basin pedestal, with rowel plug and screws etc. all
complete approved and accepted by the Engineer.
PWD SoR 2014 for Civil Works 154
26.12.1 Standard
26.12.1.3 BISF -Special coloured approx. 670x186x170, 6.5kg each Tk. 1,186.00
26.12.2 Super
26.12.3 Superior
26.13 Supplying, fitting and fixing glazed vitreous standing bowl urinal, fitting, fixing the
same in position after making holes in walls and floors, providing 32 mm dia plastic
waste pipe with brass coupling up to grading below, 12 mm dia plastic connection
pipe with brass coupling, 12 mm dia brass stop cock including mending good the
damages with cement mortar (1:4) etc. all complete approved and accepted by the
Engineer.
26.13.1 Standard
26.13.1.4 BISF -Special coloured approx. 485x360x290, 9.0kg each Tk. 2,406.00
26.13.2 Super
26.14 Supplying, fitting and fixing glazed vitreous china flat or squatting urinal
510x380x85mm in size, approx. 9.5 kg by weight with flushing inlet fitted in cement
mortar (1:4) with painted cast iron body: one gallon capacity, automatic flushing
cistern in each group etc. including 12 mm brass controlling valve, 32 mm dia PVC
flush pipe with brass coupling, 12 mm dia plastic lead (connection) pipe including
mending good the damages with 1:4 cement mortar etc. all complete approved and
accepted by the Engineer.
PWD SoR 2014 for Civil Works 155
26.15 Supplying, fitting and fixing ,porcelain sink fitted and fixed with heavy type C.I.
brackets, 12 mm dia C.P. bib cock, 40 mm dia C.P. chain plug. 40 mm dia. C.P.
waste, 40 mm dia PVC waste pipe with brass coupling (750 mm length) including
making holes in walls and floors and mending good the damages with cement mortar
(1:4) etc. all complete approved and accepted by the Engineer.
26.16 Supplying, fitting and fixing single bowl stainless steel sink with sink tray size each Tk. 4,090.00
(450 x 1050 mm.) with heavy type CI steel brackets 12mm dia C.P. bib-cock 40 mm
dia C.P. chain plug. 40 mm dia C.P. waste. 40 mm dia PVC waste pipe with brass
coupling (750 mm length) including making hole in walls and floors and mending
good the damages, finishing with 1:4 cement mortar etc. all complete approved and
accepted by the Engineer. (Malaysia / Singapore / Thailand made or equivalent)
26.17 Supplying, fitting and fixing double bowl stainless steel sink with sink tray with each Tk. 7,596.00
heavy type CI or steel brackets 12 mm dia C.P. chain plug. 40 mm dia C.P. waste,
40 mm dia PVC waste pipe with brass coupling (750 mm length) including making
hole in walls and floors and mending good the damages, finishing etc. all complete
approved and accepted by the Engineer. (Malaysia / Singapore / Thailand made or
equivalent)
26.18 Supplying, fitting and fixing of 450 x 600 mm size and 5 mm thick unframed super each Tk. 786.00
quality mirror with hard boards at the back with all necessary fitting including
making holes in walls and mending good the damages with cement mortar (1:4) etc.
all complete approved and accepted by the Engineer. (Made in Japan or equivalent)
26.19 Supplying, fitting and fixing of 450 x 350 mm size and 5 mm thick unframed super each Tk. 621.00
quality mirror with hard boards at the back with all necessary fitting including
making holes in walls and mending good the damages with cement mortar (1:4) etc.
all complete approved and accepted by the Engineer. (Made in Japan or equivalent)
26.20 Supplying, fitting and fixing super quality 600 x 125 mm coloured glass (plate) each Tk. 1,258.00
shelf having 5 mm thickness with fancy C.P. brackets, screws and frames including
making holes in walls and mending good the damages with cement mortar (1:4) etc.
all complete approved and accepted by the Engineer.
26.21 Supplying, fitting and fixing super quality 600 x 125 mm white glass (plate) shelf each Tk. 689.00
having 5 mm thickness with fancy C.P. brackets, screws and frames including
making holes in walls and mending good the damages with cement mortar (1:4) etc.
all complete approved and accepted by the Engineer.
26.22 Supplying, fitting and fixing super quality C.P. Towel rail of 600 mm long and 20 each Tk. 637.00
mm in dia with C.P. holder including making holes in walls and mending good the
damages with cement mortar (1:4) etc. all complete approved and accepted by the
Engineer.
PWD SoR 2014 for Civil Works 156
26.23 Supplying, fitting and fixing medium quality C.P. Towel rail of 600 mm long and 20 each Tk. 537.00
mm in dia with C.P. holder including making holes in walls and mending good the
damages with cement mortar (1:4) etc. all complete approved and accepted by the
Engineer.
26.24 Supplying, fitting and fixing standard toilet paper holder of 150 x 150 x 126 mm size
including making holes in walls and mending good the damages with cement mortar
(1:4) etc. all complete approved and accepted by the Engineer.
26.25 Supplying, fitting and fixing of special coloured toilet paper holder Size (150 mm x
150 mm x 126 mm) including making holes in walls and mending good the damages
with cement mortar (1:4) etc. all complete approved and accepted by the Engineer.
26.25.2 - do - Standard size stainless steel bracket and holder rod with cover. each Tk. 406.00
26.25.3 - do - Standard size, C.P iron bracket with plastic holder rod. each Tk. 340.00
26.26 Supplying, fitting and fixing standard size soap tray including making holes in walls
and mending good the damages with cement mortar (1:4) etc. all complete approved
and accepted by the Engineer.
26.27 Supplying, fitting and fixing 125 mm dia stainless steel floor grating in traps or in each Tk. 198.00
drains including making holes in walls/floors and mending good the damages with
cement mortar (1:4) etc. all complete approved and accepted by the Engineer.
26.28 Supplying, fitting and fixing 62 mm dia stainless steel floor grating in traps or in each Tk. 145.00
drains including making holes in walls/floors and mending good the damages with
cement mortar (1:4) etc. all complete approved and accepted by the Engineer.
26.29 Supplying, fitting and fixing plastic grating with hinged cover size 150 x 150 mm in each Tk. 345.00
traps or in drains including making holes in walls/floors and mending good the
damages with cement mortar (1:4) etc. all complete approved and accepted by the
Engineer.
PWD SoR 2014 for Civil Works 157
26.30 Supplying 100 mm inside diameter HCI rainwater down pipe, fitting and fixing in rm Tk. 1,864.00
position with head and shoes, bends, trap, tee, offset, clamps and nails etc. complete
in all floors approved and accepted by the Engineer.
26.31 Supplying 100 mm inside diameter best quality uPVC rain water down pipe fitting, rm Tk. 642.00
fixed in position with head and shoes, bends, min.20 mm width F.I. Bar clamp and
nails, and including all accessories such as round grating/domed roof grating bands,
sockets approved and accepted by the Engineer.
26.32 Supplying 50 mm inside dia HCI soil, waste and ventilation pipe each piece rm Tk. 962.00
having over length 1800 mm, thickness 6.5mm, spigot diameter 80 mm, weight min
12 kg fitted and fixed in position with sockets thickness min 8.5 mm, internal depth
min 68 mm, bead's outside diameter min 90 mm, ears flange length min 150 mm,
caulking clearance min 10 mm produced in foundry grade pig iron as per BSTI
approved manufacturer standard fitting and fixing in position including head and
shoes bends made of minimum 20 mm x 3 mm F.I. bar or equivalent, trap, tee,
offset, clamps and nails etc. complete in all floors approved and accepted by the
Engineer.
26.33 Supplying 100 mm inside dia HCI soil, waste and ventilation pipe each piece rm Tk. 1,813.00
having over length 1800 mm, thickness 6.5 mm, spigot diameter 117 mm, weight min
24.85 kg fitted and fixed in position with sockets thickness min 6.5 mm, internal
depth min 75 mm, bead's outside diameter min155 mm, ears flange length min 208
mm, caulking clearance min 8 mm produced in foundry grade pig iron as per BSTI
approved manufacturer standard fitting and fixing in position including head and
shoes bends made of minimum 20 mm x 3 mm F.I. bar or equivalent, trap, tee,
offset, clamps and nails etc. complete in all floors accepted by the Engineer.
26.34 Supplying 150 mm inside dia HCI soil, waste and ventilation pipe each piece rm Tk. 2,640.00
having over length 1800 mm, thickness 6.5mm, spigot diameter 117mm, weight min
41kg fitted and fixed in position with sockets thickness min 7mm, internal depth min
100 mm bead's outside diameter min 200mm, ears flange length min 258 mm,
caulking clearance min 9 mm produced in foundry grade pig iron fitting and fixing in
position including head and shoes, bends, trap, tee, off-set, clamps and nails etc.
complete in all floors approved and accepted by the Engineer.
26.35 Supplying 50 mm inside dia best quality uPVC soil, waste and ventilation pipe rm Tk. 446.00
having specific gravity 1.35 - 1.45, wall thickness 2.5 - 3.0 mm, and other physical,
chemical, thermal, fire resistivity properties etc. as per BSTI approved manufacturer
standards or ASTM, BS/ISO/IS standards fitted and fixed in position with sockets,
bends, of uPVC Pipe with all accessories such as Round grating /domed roof grating
bands, sockets etc. approved and accepted by the Engineer (length: 6000 mm
each).
26.36 Supplying 100 mm inside dia best quality uPVC soil, waste and ventilation pipe rm Tk. 739.00
having specific gravity 1.35-1.45, wall thickness 3.4- 4.0 mm, and other physical,
chemical, thermal, fire resistivity properties etc. as per BSTI approved manufacturer
standards or ASTM, BS/ISO/IS standards fitted and fixed in position with sockets,
bends, with all accessories such as Round grating/domed roof grating bands,
sockets etc. approved and accepted by the Engineer (length: 6000 mm each).
PWD SoR 2014 for Civil Works 158
26.37 Supplying 150 mm inside dia best quality uPVC soil, waste and ventilation pipe rm Tk. 1,073.00
having specific gravity 1.35 - 1.45, wall thickness 4.5 mm - 5.2 mm, and other
physical, chemical, thermal, fire resistivity properties etc. as per BSTI approved
manufacturer standards or ASTM, BS/ISO/IS standards fitted and fixed in position
with sockets, bends, with all accessories such as Round grating/domed roof grating
bands, sockets etc. approved and accepted by the Engineer (length: 6000 mm
each).
26.38 Supplying, fitting and fixing G.I. pipe conforming to the standard BS-1387 & BDS-
1031, having chemical composition (in%) Carbon 0.17-0.25, Manganese 0.95-1.20,
Sulphur 0.060 max, Phosphorous 0.060 max, Tensile properties : miminum Yield
Strength 188 MPa, minimum Tensile Strength 313 MPa and marking for a)
Manufacturer b) Material c) Wall thickness d) Nominal outside dia e) Intended
use etc. on the body of the pipe with all special fittings, such as bends, elbows,
sockets, reducing sockets, tee, unions, jam-nuts etc. including cutting trenches
where necessary and fitting the same with earth duly rammed and fixing in walls with
holder bats and making hole in floors, walls and consequent mending good the
damages etc. all complete in all respects approved and accepted by the Engineer.
(Pipes manufactured by National Tubes Limited under Steel & Engineeing Corporation,
Ministry of Industries, Government of Bangladesh shall be given priority)
26.38.1 15 mm dia G.I. pipe with wall thickness 2.65 mm, outside diameter min 21 mm, rm Tk. 301.00
weight 1.31 kg/m, can withstand min 50 kg/cm2 hydraulic pressure.
26.38.2 20 mm dia G.I. Pipe with wall thickness 2.65 mm, outside diameter min 26.5 mm, rm Tk. 390.00
weight 1.70 kg/m, can withstand min 50 kg/cm2 hydraulic pressure.
26.38.3 25 mm dia G.I. Pipe with wall thickness 3.25 mm, outside diameter min 33.3 mm, rm Tk. 508.00
weight 2.59 kg/m, can withstand min 50 kg/cm2 hydraulic pressure.
26.38.4 32 mm dia G.I. Pipe with wall thickness 3.25 mm, outside diameter min 42 mm, rm Tk. 644.00
weight 3.33 kg/m, can withstand min 50 kg/cm2 hydraulic pressure.
26.38.5 40 mm dia G.I. Pipe with wall thickness 3.25 mm, outside diameter min 47.9 mm, rm Tk. 869.00
weight 3.83 kg/m, can withstand min 50 kg/cm2 hydraulic pressure.
26.38.6 50 mm dia G.I. Pipe with wall thickness 3.65 mm, outside diameter min 59.7 mm, rm Tk. 1,083.00
weight 5.38 kg/m, can withstand min 50 kg/cm2 hydraulic pressure.
26.38.7 62~65 mm dia G.I. Pipe with wall thickness 3.25 mm, outside diameter min 75.2 mm, rm Tk. 1,541.00
weight 6.15 kg/m, can withstand min 50 kg/cm2 hydraulic pressure.
26.38.8 75~80 mm dia G.I. Pipe with wall thickness 3.25 mm, outside diameter min 87.9 mm, rm Tk. 1,899.00
weight 7.22 kg/m, can withstand min 50 kg/cm2 hydraulic pressure.
26.38.9 100 mm dia G.I. Pipe with wall thickness 3.65 mm, outside diameter min 113 mm, rm Tk. 2,520.00
weight 10.42 kg/m, can withstand min 50 kg/cm2 hydraulic pressure.
Supplying different inside dia uPVC pressure pipe C-Grade / Having density 1350
26.39
kg/m3, opacity 0.2% of visible light as per ISO 7686, minimum required strength 25
MPa conforming to BDS-1:2013, 4.4.1, 4.4.2 for water supply having specific
gravity 1.35 - 1.45, and other physical, chemical, thermal, fire resistivity properties
etc. as per BSTI approved manufacturer standards or ASTM, BS/ISO/IS standards
fitted and fixed in position with sockets, bends, with all accessories such as Round
grating/domed roof grating, bends, sockets etc. approved and accepted by the
Engineer. (length: 6000 mm each)
PWD SoR 2014 for Civil Works 159
26.40 Supplying different inside dia best quality CPVC pressure pipe Having density 1350
kg/m3, opacity 0.2% of visible light as per ISO 7686, minimum required strength 25
MPa conforming to BDS-1:2013, 4.4.1, 4.4.2 for water supply having specific
gravity 1.35 - 1.45, and other physical, chemical, thermal, fire resistivity properties
etc. as per BSTI approved manufacturer standards or ASTM, BS/ISO/IS standards
fitted and fixed in position with sockets, bends, with all accessories such as Round
grating/domed roof grating, bends, sockets etc. approved and accepted by the
Engineer. (length: 6000 mm each)
26.41 Supplying different inside dia best quality ABS pressure pipe for water supply
having specific gravity 1.35 - 1.45, and other physical, chemical, thermal, fire
resistivity properties etc. as per BSTI approved manufacturer standards or ASTM,
BS/ISO/IS standards fitted and fixed in position with sockets, bends, with all
accessories such as Round grating/domed roof grating, bends, sockets etc.
approved and accepted by the Engineer. (length: 6000 mm each)
26.42 Supplying, fitting and laying HCI soil pipe each piece having over length 1800 mm,
thickness 5.5 mm, spigot diameter 116 mm, weight min 24.85 kg fitted and fixed in
position with sockets thickness min 6.5 mm, internal depth min 75 mm, bead's
outside diameter min 155 mm, ears flange length min 208 mm, caulking clearance
min 7.5 mm produced in foundry by grade pig iron as per BSTI approved
manufacturer standard fitting and fixing in position including head, shoes, bends,
trap, tee, offset, clamps and nails etc. complete in all floors approved and accepted
by the Engineer.
26.43 Supplying, fitting and laying up to depth of invert 100 mm inside dia best quality
uPVC pressure soil pipe having specific gravity 1.3 -1.45, and other physical,
chemical, thermal, fire resistivity properties etc. as per BSTI approved manufacturer
standards or ASTM, BS/ISO/IS standards fitted and fixed in position with sockets,
bends, with all accessories such as Round grating/domed roof grating etc. complete
approved and accepted by the Engineer (length: 6000 mm each).
26.43.1 uPVC soil pipe 100 mm dia wall thickness 2.7 mm - 3.4 mm, rm Tk. 553.00
26.43.2 uPVC soil pipe 150 mm dia wall thickness 4.0 mm - 4.5 mm, rm Tk. 724.00
26.44 Supplying, fitting and fixing laying Pipes up to depth of invert dia R.C.C pipe having
1.83 meter in length made of stone chips with 40 mm cement joint including all
fittings and specials like plain bend, Tees, reducing sockets, junctions, door bends
cowls, anti-siphon, gasket and cement joints, making holes in walls and mending
good the damages etc. all complete approved and accepted by the Engineer.
26.44.1 R.C.C pipe of 150 mm dia with thickness 40mm rm Tk. 864.00
26.44.2 R.C.C pipe of 225 mm dia with thickness 40mm rm Tk. 1,347.00
26.44.3 R.C.C pipe of 300 mm dia with thickness 50mm rm Tk. 2,213.00
26.44.4 R.C.C pipe of 375 mm dia with thickness 50mm rm Tk. 2,843.00
26.45 Supplying 100 mm dia uPVC pipe for waste including fitting, fixing etc. all complete rm Tk. 575.00
approved and accepted by the Engineer.
26.46.1 Supplying 150 mm dia uPVC pipe for underground laying including fitting, fixing etc. rm Tk. 764.00
all complete approved and accepted by the Engineer.
26.46.2 Supplying 200 mm dia uPVC for underground laying including fitting, fixing etc. all rm Tk. 1,459.00
complete approved and accepted by the Engineer.
26.46.3 Supplying 250 mm dia uPVC for underground laying including fitting, fixing etc. all rm Tk. 2,019.00
complete approved and accepted by the Engineer.
26.46.4 Supplying uPVC waste pipe 280 mm dia with wall thickness 6.9 mm - 8.6 mm for rm Tk. 2,463.00
underground laying including fitting, fixing etc. all complete approved and accepted
by the Engineer.
PWD SoR 2014 for Civil Works 161
26.46.5 Supplying uPVC waste pipe 315 mm dia with wall thickness 7.7 mm - 9.7 mm for rm Tk. 3,368.00
underground laying including fitting, fixing etc. all complete approved and accepted
by the Engineer.
26.47 Supplying, fitting and fixing G.I. Union with sealant etc. complete in all respects
approved and accepted by the Engineer.
26.48 Supplying, fitting and fixing best quality G.I. gate valve with sealant etc. complete
approved and accepted by the Engineer.
26.49 Supplying, fitting and fixing best quality G.I. Globe valve, threaded joint with sealant
etc. complete approved and accepted by the Engineer.
26.50 Supplying, fitting and fixing best quality G.I. Check valve, threaded joint with sealant
etc. complete approved and accepted by the Engineer.
26.51 Supplying, fitting and fixing best quality G.I. Float valve, threaded joint Pit valve etc.
complete approved and accepted by the Engineer.
26.52 Supplying, fitting and fixing European type HCI P-Trap drainage pipe preparing the
base with cement concrete in 1:2:4 and with wire mesh or rods if necessary, in all
floors including making holes wherever required and mending good the damages
and fitting, fixing complete with all necessary fittings and connection approved and
accepted by the Engineer.
26.52.2 100 x 100 mm or 100 x 50 mm size HCI Y or T-Y Cleanout each Tk. 1,249.00
PWD SoR 2014 for Civil Works 163
26.52.3 150 x 150 mm or 150 x 100 mm size HCI T-Y or Y Cleanout each Tk. 1,572.00
26.53 Supplying different inside dia best quality uPVC pressure waste pipe having
specific gravity 1.35 -1.45, wall thickness 2.7 mm - 3.4 mm, and other physical,
chemical, thermal, fire resistivity properties etc. as per BSTI approved manufacturer
standards or ASTM, BS/ISO/IS standards, fitted and fixed in position with sockets,
bends, with all accessories such as Round grating/domed roof grating bands,
sockets etc. complete approved and accepted by the Engineer.
26.53.2 100 mm dia uPVC ‘P’ or ‘S’ trap each Tk. 575.00
26.54. Supplying, fitting and fixing best quality faucets etc. complete approved and
accepted by the Engineer
26.55 Supplying, fitting and fixing best quality CP pillar cock etc. complete approved and
accepted by the Engineer
26.56 Supplying, fitting and fixing best quality concealed fixed sink cock etc. complete
approved and accepted by the Engineer
26.57.1 Supplying, fitting and fixing CP Basin Mixture with all necessary hardware and each Tk. 2,338.00
consumables approved and accepted by the Engineer.
26.57.2 Supplying, fitting and fixing CP Single Handle Basin Mixture with all necessary each Tk. 1,934.00
hardware and consumables approved and accepted by the Engineer.
26.58 Supplying, fitting and fixing CP Shower Mixture including Shower Head only with each Tk. 3,404.00
all necessary hardware and consumables approved and accepted by the Engineer.
26.59 Supplying, fitting and fixing CP Shower Mixture including Shower Head and each Tk. 4,867.00
faucet with all necessary hardware and consumables approved and accepted by the
Engineer.
PWD SoR 2014 for Civil Works 164
26.60 Supplying, fitting and fixing CP Bath tub Mixture with Shower Head only including each Tk. 5,110.00
all necessary hardware and consumables approved and accepted by the Engineer.
26.61 Supplying, fitting and fixing CP Self closing pillar cock with all necessary hardware each Tk. 971.00
and consumables approved and accepted by the Engineer
26.62 Supplying, fitting and fixing Special/Fancy quality C.P. concealed/ surface stop
cock with all necessary hardware and consumables approved and accepted by the
Engineer.
26.62.1 12 mm brass Stop Cock for Surface Mount (general quality) each Tk. 307.00
26.62.2 12 mm CP Stop Cock for Surface Mount (medium quality) each Tk. 382.00
26.62.3 12 mm CP Stop Cock for Surface Mount (special type) each Tk. 919.00
26.63 Supplying, fitting and fixing Special/Fancy quality C.P. concealed/ Surface Angle
stop cock etc. complete approved and accepted by the Engineer.
26.63.1 12 mm CP surface mounted angle stop cock (general) each Tk. 789.00
26.63.2 12 mm CP medium quality surface & heavy type fancy angle stop cock each Tk. 827.00
26.63.3 12 mm surface special heavy type angle stop cock each Tk. 795.00
26.63.6 Special concealed heavy type angle stop cock each Tk. 952.00
26.64 Groove cutting in brick work, R.C.C floor, including cost for concealing of G.I. pipe
work (12 mm and 20 mm dia) in brick wall by cutting groove in wall, lintel, beam etc.
by any means carefully without damaging the structure and filling the grooves with
C.C (4:2:1) after laying of pipe including cost of scaffolding, finishing, curing etc. all
complete approved and accepted by the Engineer.
26.65 Supply and fitting-fixing cleansing shower for ablution including holder of following
types:
26.66 Supply and fitting-fixing hand / push shower for ablution including holder
PWD SoR 2014 for Civil Works 165
26.67 Supplying, fitting fixing of food grade plastic overhead water reservoir tank
including all necessary fittings, hardware and consumables etc. all complete
approved and accepted by the Engineer.
26.68 Supply and installation of food-grade plastic internal mini water tank for the use in
kitchen, bathroom and toilet for emergency storage and supply of water
manufactured from liner low density polyethylene (ILDPE) roto-grade (ultra violet)
stabilized which complies FDA (Federal Department of Agriculture, USA) regulations
21 CFR 1277. 152, having food grade quality where no recycled material is used
carrying, lifting, fitting, fixing in position including supply of necessary hardware,
consumables, fittings etc. all complete approved and accepted by the Engineer.
26.69 Supply and installation of foreign made food grade stainless steel water tank
including supply of hardware, consumables, fittings etc. all complete approved and
accepted by the Engineer.
26.70 Supply and installation of 400 gallon capacity Ferro-cement water tank including each Tk. 7,886.00
necessary hardware, fittings and consumables etc. all complete approved and
accepted by the Engineer.
26.71 Supplying, fitting and fixing 12 mm dia, 450 mm long Plastic flexible lead each Tk. 65.00
(connection) pipe approved and accepted by the Engineer.
26.72 Supplying, fitting and fixing 12 mm dia, 600 mm long Plastic flexible lead each Tk. 99.00
(connection) pipe approved and accepted by the Engineer.
26.73 Supplying, fitting and fixing 12 mm dia 450 mm long metal cover connection pipe each Tk. 350.00
approved and accepted by the Engineer.
PWD SoR 2014 for Civil Works 166
26.74 Supplying, fitting and fixing 12 mm dia 600 mm long metal cover connection pipe each Tk. 399.00
approved and accepted by the Engineer.
26.75 Construction of masonry inspection pit with 250 mm thick brick work in cement
mortar (1:4) including necessary earth work, side filling and one layer brick flat
soling, 75 mm thick (1:3:6) base concrete for making invert channel and 12 mm thick
(1:2) cement plaster with neat finishing etc. all complete up to a depth of 700 mm
approved and accepted by the Engineer.
26.75.1 Clear 450 x 450 mm and depth 450 to 600 mm, average 525 mm for single 150 mm each Tk. 3,433.00
dia R.C.C. pipes and 400 mm PVC pipe.
26.75.2 Clear 520 x 525 mm and depth 675 to 825 mm, average 750 mm for single 225 mm each Tk. 5,012.00
dia R.C.C. pipes and 400 mm PVC pipe.
26.75.3 Clear 600 x 600 mm and depth 750 to 900 mm, average 825 mm for single 300 mm each Tk. 6,882.00
dia R.C.C. pipes and 375 mm and 400 mm PVC pipe.
26.75.4 Master-pit of Size: Clear 600 x 500 mm and average 750 mm depth for Septic tank. each Tk. 3,710.00
26.76 Construction and placing of R.C.C. inspection pit cover (slab) in (1:2:4) with 1%
reinforcement excluding M.H. cover with locking/unlocking arrangement including
necessary earth work, side filling shuttering, curing, cement plaster (1:4) with neat
finishing on edges and top etc. all complete approved and accepted by the Engineer.
26.77 Construction and placing of R.C.C inspection pit cover (slab) with supplying and
provisions for placing, fitting, fixing 450 mm dia C.I. Man-hole cover with locking/un-
locking arrangement including concrete (1:2:4) with approx. 1% re-enforcement,
necessary earth cutting, or cleaning, side filling, curing etc. with minimum 12 mm
cement plaster (1:4) and neat cement finishing on edges and top all complete and
accepted by the Engineer.
26.77.1 950 x 950 x 75 mm R.C.C. pit cover with 450 mm dia C.I. manhole cover. each Tk. 2,371.00
26.77.2 1025 x 1025 x 75 mm R.C.C. pit cover with 450 mm dia C.I. manhole cover. each Tk. 2,534.00
26.77.3 1100 x 1100 x 75 mm R.C.C. pit cover with 450 mm dia C.I. manhole cover. each Tk. 2,755.00
26.78 Construction of masonry inspection pits up to a depth of 700 mm with 250 mm thick
brick work in cement mortar (1:4) including 100 mm thick R.C.C. top slab (1:2:4)
with 1% reinforcement, man-hole cover with locking arrangement including
necessary earth work, side filling and one brick flat soling. 75 mm thick (1:3:6) base
concrete for making invert channel and 12 mm thick (1:2) cement plaster with neat
finishing etc. all complete approved and accepted by the Engineer.
26.78.1 Clear 450 x 450 mm and depth 450 to 600 mm, average 525 mm for single 150 mm each Tk. 5,804.00
dia R.C.C. pipes and 400 mm PVC pipe with pit cover and 450 mm dia C.I. man-hole
cover.
PWD SoR 2014 for Civil Works 167
26.78.2 Clear 525 x 525 mm and depth 675 to 825 mm, average 750 mm for single 225 mm each Tk. 7,546.00
dia R.C.C. pipes and 400 mm PVC pipe with pit cover and 450 mm dia C.I. man-hole
cover.
26.78.3 Clear 600 x 600 mm and depth 750 to 900 mm, average 825 mm for single 300 mm each Tk. 9,637.00
dia R.C.C. pipes and 375 mm and 400 mm PVC pipe with pit cover and 450 mm dia
C.I. man-hole cover.
26.79 Construction of septic tank of different sizes with walls of brick work in cement
mortar (1:6) having a lining of minimum 125 mm R.C.C cast against the walls as per
approved type plan over a brick flat soling and 150 mm thick reinforced cement
concrete flooring (1:2:4) with 125 mm thick walls in partition and 12 mm thick cement
plaster (1:4) with N.C.F. to insides of walls on floor and all around outside walls by
18" height at top including supplying fitting and fixing of two R.C.C. Tees and
providing 450 mm dia water sealed heavy type C.I. manhole cover with
locking/unlocking arrangement and 100 mm thick R.C.C (1:2:4) top slab, including
centering, shuttering, fabricating, casting and curing etc. complete up to required
depth including necessary earth work in excavation and shoring, bailing out water
and side filling including the cost of all materials, operations and incidental charges.
etc. all complete as per type plan approved and accepted by the Engineer. (Rate is
including cost of reinforcement and its fabrication, binding and placing)
26.80 Construction of soak well of different sizes (medium and large sizes) with 250 mm
thick solid brick work and 250 mm honey comb brick work with cement mortar (1:6)
as per design over R.C.C. (1:2:4) well curb with 1% reinforcement up to the depth as
per drawing with 450 mm dia water sealed heavy type. C.I. manhole cover with
locking arrangement, filling the well up to the required depth with graded khoa and
sand including supplying and fabricating M.S. Rod, casting, curing including
necessary earth work in excavation, side filling and bailing out water including cost of
all materials etc. all complete as per drawing, design approved and accepted by the
Engineer. (Rate is including cost of reinforcement and its fabrication, binding and
placing)
26.81 Construction of soak well of different sizes (small sizes) with 250 mm thick solid
brick work and 250 mm honey comb brick work with cement mortar (1:6) as per
design over R.C.C. (1:2:4) well curb with 1% reinforcement up to the depth as per
drawing with 450 mm dia water sealed heavy type. C.I. manhole cover with locking
arrangement, filling the well up to the required depth with graded khoa and sand
including supplying and fabricating M.S. Rod, casting, curing including necessary
earth work in excavation, side filling and bailing out water including cost of all
materials etc. all complete as per drawing, design approved and accepted by the
Engineer.
26.82 Supplying, fitting, fixing of Reverse Osmosis Water Purifier of foreign made for
purification of water by reverse osmosis system to have potable water confirming
WHO standard and Bangladesh concentration parameters including installation
charge, carriage, sundries etc. complete approved and accepted by the Engineer.
(excluding cost of pipe, pipe line laying and accessories required for pipe line laying)
26.82.1 Water purification vol.: 50 Gallon /day water reserve capacity: 11 liter each Tk. 21,318.00
26.82.2 Water purification volume: 75 gallon per day (Without meter) each Tk. 25,238.00
26.82.3 Water purification volume: 75 gallon per day (With meter) each Tk. 26,636.00
26.82.4 Water purification volume: 100 gallon per day each Tk. 79,433.00
26.83 Supply, installation and commissioning of 50 liter capacity best quality ‘Water each Tk. 4,391.00
Dispenser’ with container of approved brand/origin.
26.84 Punching or cutting hole of any diameter for sanitary works. each Tk. 666.00
(Note: Tender for test & observation well must be called beforehand. Tender
for main production well will then be called on the basis of required data
obtained from the test well. Requirements of water must be guiding factor in
dimensioning the main well.
27.1 Mobilization for test boring or observation well: Transportation of materials, Per set Tk. 7,034.00
equipments, tools and plants and boring rig to work site. Construction of derrick and
dismantling the same. Cleaning the site after completion of the work accepted by the
Engineer.
27.2 Boring by using 100 mm dia cutter and 40 mm dia heavy type G.I pipe having wall
thickness 2.9 mm, outside diameter min 47.8 mm, weight 3.517 kg/m, capability to
withstand 50 kg/cm2 and other equipments capable of drilling up to a depth 500
meter by water jet system through all sorts of strata. Protection of caving by
supplying necessary casing pipe. Collection of soil samples at every 3 meter interval
and at every change of strata and preserves them in a controlled environment for
analysis and laboratory test. Finally withdrawal of boring and casing pipes etc.
complete and accepted by the Engineer.
27.3 Installation of tube-well fixture for observation well: Supplying and lowering of
40/38 mm inside dia best quality uPVC pressure tube well pipe having specific
gravity 1.35 - 1.45, wall thickness 2.5 mm - 3.0 mm, capability to withstand a
minimum hydrostatic pressure of 170 psi for 1 hr. fitted and fixed in position with all
accessories, uPVC sand trap of length 3.00m with uPVC strainer of desired slot
installing in or at mid depth of the most suitable water bearing strata. 38 mm dia G.I.
pipe of best quality of length 1.52 m with M.S. welded flat bar on each side to prevent
from rotation up to desired depth, fitting fixing the best quality No. 6 C.I. head hand-
pump etc including the cost of solvent cement, socket adaptor, filling medium sand
up to 18.00 m above strainer and the remaining portion with available soil from
boring etc. complete as per standard specification and accepted by the Engineer.
27.3.1 Fitting, fixing No. 6 Hand-pump set including all necessary accessories etc complete each Tk. 2,738.00
and accepted by the Engineer.
PWD SoR 2014 for Civil Works 170
27.3.2 38/40 mm dia heavy type G.I pipe conforming to standard BS-1387 & BDS-1031, rm Tk. 680.00
having chemical composition (in%) Carbon 0.17-0.25, Manganese 0.95-1.20,
Sulphur 0.060 max, Phosphorous 0.060 max, Tensile properties: miminum Yield
Strength 188 MPa, minimumTensile Strength 313 MPa and marking for a)
Manufacturer b) Material c) Wall thickness d) Nominal outside dia e) Intended use
etc. on the body of the pipe having wall thickness 2.9 mm, weight 3.517 kg/m
capability to withstand 50 kg/cm2 hydraulic pressure.
27.3.3 38/40 mm dia water grade uPVC pipe having wall thickness 2.5-3.00 mm rm Tk. 141.00
27.3.4 38/40 mm dia water grade uPVC strainer having thickness 2.5-3.00 mm rm Tk. 175.00
27.3.7 Supplying, fitting fixing observation well inside the housing pipe of the deep tube each Tk. 21,806.00
well: 100'-0" depth
27.3.8 Supplying, fitting fixing tube-well log describing technical information of the tube-well each Tk. 2,859.00
as per instruction and accepted by the Engineer.
27.3.9 Filling the top 0.6 meter of the bore hole around the top pipe with sanitary seal of each Tk. 51.00
concrete of proportion 1:2:4 as per design accepted by the Engineer.
27.4 Complete development of the tube well to obtain sand and turbidity free water at a
satisfactory yield confirmed by tests as per specification and accepted by the
Engineer. Water sample must be taken from 3 separate aquifers from three tube-
well.
27.5 "Furnishing design of a production well by testing of water and soil samples from
a test bores up to 350 m depth collecting samples of water from the best suitable
aquifer, filling in sterilized air-tight glass bottles having no air space inside; collecting
soil (sand, solids etc) at 3 m interval and at each change of soil strata from the bores,
arranging them in the cell of a box in an orderly manner. carrying out test of water for
(1) pH, (2) CO2 (3) Chloride, (4) Fluoride, (5) Iron, (6) Manganese, (7) Nitrate-
Nitrogen, (8)Total alkalinity, (9) Total hardness, (10) Arsenic, (11) Turbidity, followed
by test reports along with Bangladesh Standards of potable water and (12) Sieve
analysis on soils throughout a bore, leading to ascertain the best suitable sustained
aquifers, depths and slot sizes of strainer, types and dia of tube well for specific
yield, thickness of shrouding around strainer, fineness modulus of shrouding
materials, mechanical units (pumps, compressor) for testing and operation of the
tube well, maintaining test bore functional till tube well installation, testing etc. is
finished, finally filling and sealing the left over test bore permanently, including
carrying water and soil samples under direct responsibility of Engineer-in-charge to
BRTC, BUET or other reputed laboratory, approved by the authority, submitting the
report and design details all complete and accepted by the Engineer and maintaining
the mobilized tools and plant at site till satisfactory test results are found (if not, next
test bore may be executed with the approval of concern S.E. / Design Office)
Total No. of test on water: 11 types of test x 1 test bore x one set sample (3
specimen) = 11 Nos. test (each specimen 1.5 liter of water)
Sieve analysis: min 9 Nos. Sample x one test x One bore = 9 Nos. test
(Samples are of 1 kg dry wt. each)"
There are about 55 (fifty-five) tests for potable water Quality Standard according to
Bangladesh Environment Conservation Rules-12 (Schedule-3), 1997, under ECA
1995 of Ministry of Environment and Forest. Therefore, additional test/ tests on water
or sieve analysis of soil if required, other than the above specified 12 (twelve) tests,
may be carried out for public interest as per direction of the design engineer on
actual payment including profit, VAT and all other charges.
27.5.1 Furnishing design considering 1 No. test bore L.S. Tk. 32,223.00
27.5.2 Furnishing design considering 2 Nos. test bore L.S. Tk. 53,237.00
27.5.3 Furnishing design considering 3 Nos. test bore L.S. Tk. 79,855.00
27.6 Disinfections of the well by using minimum 3 kg of bleaching powder of 33% each Tk. 380.00
strength or any other disinfectant as per standard specification and accepted by the
Engineer.
PRODUCTION WELL
27.7.1 For Tube-wells up to 100 meter depth Per set Tk. 35,302.00
PWD SoR 2014 for Civil Works 172
27.7.2 For Tube-wells up to 200 meter depth Per set Tk. 37,824.00
27.7.3 For Tube-wells beyond 200 meter depth Per set Tk. 40,345.00
27.8 Preparation and making gravel pack around the tube well fixtures with supply of cum Tk. 3,087.00
designed graded pea gravels free from any substance harmful to pipe and health
confirmed by test (Passing through 10 mesh and retained on 40 mesh) including
sieving, washing etc. complete as per standard specification and accepted by the
Engineer. (The rate is inclusive of the cost of extra amount required for caving and
extra depth below the tube well fixtures, shrouding should not be more than 15 m
above the strainer and measurement should be allowed from bottom of the tube-well
fixture to top of the gravel pack)
27.9 Making a sanitary seal up to a minimum depth of 6 meter from G.L. or as specified cum Tk. 7,982.00
including the supply of approved quality of cement, sand and khoa (12 mm down
graded) in ratio (1:1:5:3) as per standard specification and accepted by the Engineer.
27.10 Boring: Execution 325 mm dia of boring through all sorts of strata by reverse
circulation or any other approved method (Method other than reverse circulation is to
be applied only for wells deeper than 152 meter). Boring for 325 mm dia vertical hole
up to designed depth and collection of soil samples at every 3 meter interval or as
required and at every change in soil stratum including sinking and with drawing
necessary casing pipe and all necessary arrangements complete as per specification
and accepted by the Engineer. (Measurement will be allowed from E.G.L. to bottom
of the blind pipe and the rate is inclusive of the cost of extra depth or of further boring
required due to caving and siltation)
27.11 Supplying the following tube well fixtures and pipes having density 1350 kg/m3,
opacity 0.2% of visible light as per ISO 7686, minimum required strength 25 MPa
conforming to BDS-1:2013, 4.4.1, 4.4.2 at working site as per standard practice and
accepted by the Engineer.
27.11.2 50 mm dia water grade uPVC blind pipe/sand trap of wall thickness 2.5 to 3.00 mm rm Tk. 182.00
27.11.3 50 mm dia strainer of any slot as per design made with grade uPVC pipe of wall rm Tk. 221.00
thickness 2.5 to 3 mm
PWD SoR 2014 for Civil Works 173
27.11.5 125mm dia water grade uPVC Housing pipe of wall thickness 5.5 to 6.4mm each Tk. 736.00
27.11.6 Supplying centralizer made with 12 mm dia M.S. rod of approved design rm Tk. 364.00
27.12 Complete installation of 50 mm dia uPVC tube well fixtures such as expanded rm Tk. 66.00
top or furnishing pipe, reducer, tube well pipes, strainer, blind pipe, pipe cap etc.
fitting and fixing with best quality PVC solution, iron screws and PVC tape, sockets
and placing in position with proper size M.S. centralizer @ 3.0 meter c/c in strainer
portion including blind pipe etc. complete as per standard practice and accepted by
the Engineer.
27.13 Complete development of the tube well by air compressor and pump of suitable
capacity by alternate surging and pumping or any specified method until satisfactory
yield. is achieved in sand and turbid free water confirmed by laboratory test using
necessary quantity of cologne and conducting step drawn-down test before and after
the development as per specification and accepted by the Engineer.
(Development should be started within 24 hours of completion of shrouding)
27.14 Pumping test of the well by designed turbine/submersible pump with supply of Per hour Tk. 651.00
testing equipments for pressure/ velocity/ discharge etc. and all materials for 72
hours including yield drawn and recovery test etc. complete as per specification and
accepted by the Engineer.
27.15 Disinfections of the well including supply of sufficient quantity of bleaching powder each Tk. 1,106.00
(33% strength) to obtain chlorinated water having 150 ppm free chlorine in the well
complete as per standard specification and accepted by the Engineer.
27.16 Filling of the borehole around the tube well from top of the shrouding up to the rm Tk. 24.00
bottom of sanitary seal by withdrawn selected soil or local clay free from any
substances harmful to pipes and health as per standard specification and accepted
by the Engineer.
PWD SoR 2014 for Civil Works 174
27.17 Protective top cover: Supplying and fitting fixing best quality 150 mm dia 4 mm each Tk. 3,826.00
thick MS. Pipe 1.0 m (3'-4") long one end blocked with 200 mm dia 4 mm thick M.S.
plate and other end minimum 300 mm (1'-0") embedded in sanitary seal for
protection of uPVC Housing Pipe as per standard specification and accepted by the
Engineer.
27.18 Boring: Execution 350 mm dia of boring through all sorts of strata by reverse
circulation or any other approved method (Method other than reverse circulation is to
be applied only for wells deeper than 152 meter). Boring for 350 mm dia vertical hole
up to designed depth and collection of soil samples at every 3 meter interval or as
required and at every change in soil stratum including sinking and with drawing
necessary casing pipe and all necessary arrangements complete as per specification
and accepted by the Engineer. (Measurement will be allowed from E.G.L. to bottom
of the blind pipe and the rate is inclusive of the cost of extra depth or of further boring
required due to caving and siltation)
27.19 Supplying the following tube well fixtures and having density 1350 kg/m3, opacity
0.2% of visible light as per ISO 7686, minimum required strength 25 MPa conforming
to BDS-1:2013, 4.4.1, 4.4.2 at working site as per standard practice and accepted by
the Engineer.
27.19.2 75 mm dia water grade uPVC blind pipe/sand trap of wall thickness 3.5 to 4.1 mm rm Tk. 312.00
27.19.3 75 mm dia strainer of any slot as per design made with grade uPVC pipe of wall rm Tk. 347.00
thickness 3.5 to 4.1 mm
27.19.4 Best quality 75 mm x 150 mm dia uPVC Reducer each Tk. 769.00
27.19.5 150 mm dia water grade uPVC Housing pipe having wall thickness 6.6 mm to 7.6 rm Tk. 953.00
mm
27.19.6 Supplying centralizer made with 12 mm dia M.S. rod of approved design rm Tk. 364.00
PWD SoR 2014 for Civil Works 175
27.20 Complete installation of 75 mm dia uPVC tube-well fixtures such as expanded rm Tk. 74.00
top pipes. Reducer, tube-well pipes, strainer, blind pipe. Pipe cap etc fitting and fixing
with best quality uPVC solution, iron screws and uPVC tape and placing in position
with proper size M.S. centralizer @ 3 meter c/c .in strainer portion including blind
pipe etc. complete as per standard practice and accepted by the Engineer.
27.21 Complete development of the well by suitable air compressor and pump of suitable
capacity by alternate surging and pumping un till satisfactory yield, sand free water
and the turbidity condition is reached using necessary quantity of calgon and
conducting step draw down test before and after the development as per
specification and accepted by the Engineer. (Development should be started within
24 hours of completion of shrouding)
27.22 Pumping test of the well by designed turbine/submersible pump with supply of testing hour Tk. 807.00
equipments for pressure/ velocity/ discharge etc. and all materials for 72 hours
including yield drawn and recovery test etc. complete as per specification and
accepted by the Engineer.
27.23 Disinfections of the well including supply of sufficient quantity of bleaching powder each Tk. 1,342.00
(33% strength) chlorinated water having 150 ppm available free chlorine complete as
per standard specification and accepted by the Engineer.
27.24 Filling of the bore-hole around the tube well from top of the shrouding up to the rm Tk. 28.00
bottom of sanitary seal by withdrawn selected soil or local clay free from any
substances harmful to pipes and health as per standard specification and accepted
by the Engineer.
27.25 Protective top cover: Supplying and fitting fixing best quality 200 mm dia 4 mm each Tk. 5,317.00
thick M.S. pipe 1.0 m (3'-4") long one end blocked with 250 mm dia 4 mm thick M.S.
plate and other end minimum 300 mm (1'-0) embedded in sanitary seal for protection
of uPVC housing pipe as per standard specification and accepted by the Engineer.
27.26 Boring: Execution 400 mm dia of boring through all sorts of strata by reverse
circulation or any other approved method (Method other than reverse circulation is to
be applied only for wells deeper than 152 meter) Boring for 400 mm dia vertical hole
up to designed depth and collection of soil samples at every 3 meter interval or as
required and at every change in soil stratum including sinking and with drawing
necessary casing pipe and all necessary arrangements complete as per specification
and accepted by the Engineer.(Measurement will be allowed from E.G.L. to bottom
of the blind pipe and the rate is inclusive of the cost of extra depth or of further boring
required due to caving and siltation)
27.27 Supplying the following tube well fixtures and pipes Having density 1350 kg/m3,
opacity 0.2% of visible light as per ISO 7686, minimum required strength 25 MPa
conforming to BDS-1:2013, 4.4.1, 4.4.2 at working site as per standard practice and
accepted by the Engineer
27.27.1 Best quality 100 mm dia uPVC cap each Tk. 198.00
27.27.2 100 mm dia water grade uPVC blind pipe/ sand trap having wall thickness 4.5mm to rm Tk. 472.00
5.2mm
27.27.3 100 mm dia strainer of any slot as per design made with water grade uPVC pipe rm Tk. 507.00
having wall thickness 4.5 mm to 5.2 mm
27.27.4 Best quality 100 mm x 200 mm dia uPVC Reducer each Tk. 861.00
27.27.5 200 mm dia water grade uPVC Housing pipe having wall thickness 6.6mm to 7.8mm rm Tk. 804.00
to 9.0mm
27.27.6 Supplying centralizer made with 12 mm dia M.S. rod of approved design rm Tk. 364.00
27.28 Complete installation of 100 mm dia uPVC tube-well fixtures such as expanded rm Tk. 85.00
top pipes. Reducer, tube-well pipes. Strainer, blind pipe, pipe cap etc. fitting and
fixing with best quality PVC solution, iron screws and uPVC tape and placing in
position with proper size M.S. centralizer @ 3 meter c/c. in strainer portion including
blind pipe etc. complete as per standard practice and accepted by the Engineer.
27.29 Complete development of the tube-well by air compressor and pump of suitable
capacity by alternate surging and pumping until satisfactory yield, sand free water
and the turbidity condition is reached using necessary quantity of calgon and
conducting step draw down test before and after the development as per
specification and accepted by the Engineer.(Development should be started within
24 hours of completion of shrouding)
27.30 Pumping test of the well by designed turbine/submersible pump with supply of hour Tk. 852.00
testing equipments for pressure/ velocity/ discharge etc. and all materials for 72
hours including yield drawn and recovery test etc. complete as per specification and
accepted by the Engineer.
27.31 Disinfections of the well including supply of sufficient quantity of bleaching powder each Tk. 1,579.00
(33% strength) chlorinated water having 150 ppm available free chlorine etc.
complete as per standard specification and accepted by the Engineer.
PWD SoR 2014 for Civil Works 177
27.32 Filling of the borehole around the tube-well from top of the shrouding up to the rm Tk. 32.00
bottom of sanitary seal by withdrawn selected soil or local clay free from any
substances harmful to pipes and health as per standard specification and accepted
by the Engineer.
27.33 Protective top cover: Supplying and fitting fixing best quality 250 mm dia 4 mm each Tk. 8,468.00
thick M.S. pipe. 1.0 m (3'-4") long one end blocked with 300 mm dia 4 mm thick M.S.
plate and other end minimum 300 (1'-0") embedded in sanitary seal for protection of
uPVC Housing pipe as per standard specification and accepted by the Engineer.
27.34 Boring: Execution 600 mm dia of boring through all sorts of strata by reverse
circulation or any other approved method (Method other than reverse circulation is to
be applied only for wells deeper than 152 meter). Boring for 600 mm dia vertical hole
up to designed depth and collection of soil samples at every 3 meter interval or as
required and at every change in soil stratum including sinking and with drawing
necessary casing pipe and all necessary arrangements complete as per specification
and accepted by the Engineer. (Measurement will be allowed from E.G.L. to bottom
of the blind pipe and the rate is inclusive of the cost of extra depth or of further boring
required due to caving and siltation)
27.35 Supplying the following tube-well fixtures and pipes having density 1350 kg/m3,
opacity 0.2% of visible light as per ISO 7686, minimum required strength 25 MPa
conforming to BDS-1:2013, 4.4.1, 4.4.2 at working site as per standard practice and
accepted by the Engineer.
27.35.1 Best quality 150 mm dia uPVC cap for blind pipe/ sand trap. each Tk. 473.00
27.35.2 150 mm dia water grade uPVC blind pipe/ sand trap having wall thickness 6.6 mm rm Tk. 1,042.00
to7.6 mm
27.35.3 150 mm dia strainer of any slot as per design made with grade uPVC pipe of wall rm Tk. 1,086.00
thickness 6.6 to 7.6 mm
27.35.4 Best quality 150 mm x 200 mm dia uPVC Reducer each Tk. 999.00
27.35.5 200 mm dia water grade uPVC Housing pipe of wall thickness 6.6 mm to 7.8 mm rm Tk. 1,668.00
27.35.6 Supplying centralizer made with 12 mm dia M.S. rod of approved design rm Tk. 364.00
PWD SoR 2014 for Civil Works 178
27.36 Complete installation of 150 mm dia uPVC tube-well fixtures such as expanded rm Tk. 90.00
top pipes, reducer, tube-well pipes, strainer, blind pipe, pipe cap etc. fitting and fixing
with best quality uPVC solution, iron screws and uPVC tape and placing in position
with proper size M.S. centralizer @ 3 meter c/c in strainer portion including blind pipe
etc. complete as per standard practice and accepted by the Engineer.
27.37 Complete development of the tube well by suitable air compressor and pump of
suitable capacity by alternate surging and pumping until satisfactory yield, sand free
water and the turbidity condition is reached using necessary quantity of calgon and
conducting step draw down test before and after the development as per
specification and accepted by the Engineer. (Development should be started within
24 hours of completion of shrouding)
27.38 Pumping test of the well by designed turbine/submersible pump with supply of hour Tk. 973.00
testing equipments for pressure/ velocity/ discharge etc. and all materials for 72
hours including yield drawn and recovery test etc. complete as per specification and
accepted by the Engineer.
27.39 Disinfections of the well including supply of sufficient quantity of bleaching powder each Tk. 1,895.00
(33% strength) chlorinated water having 150 ppm available free chlorine etc.
complete as per standard specification and accepted by the Engineer
27.40 Filling of the borehole around the tube well from top of the shrouding up to the rm Tk. 43.00
bottom of sanitary seal by withdrawn selected soil or local clay as free from any
substances harmful to pipes and health per standard specification and accepted by
the Engineer.
27.41 Protective top cover: Supplying and fitting fixing best quality 250 mm dia 4 mm each Tk. 8,343.00
thick M.S. pipe 1.0 m (3'-4") long one end blocked with 300 dia 4 mm thick M.S. plate
and other end minimum 300 (1'-0") embedded in sanitary seal for protection of uPVC
Housing pipe as per standard specification and accepted by the Engineer.
27.42 Boring: Execution of 600 mm dia boring through all sorts of strata by reverse
circulation or any other approved method (Method other than reverse circulation is to
be applied only for wells deeper than 152 meter) for boring 600 mm dia vertical hole
up to designed depth and collection of soil samples at every 3 meter interval and at
every change of formation including sinking and withdrawing necessary casing pipe
and all necessary arrangements complete as per specification and accepted by the
Engineer. (Measurement will be allowed from G.L. to bottom of the blind pipe and the
rate is inclusive of the cost of extra depth of boring required for caving and siltation)
27.42.1 From 0.0 m to 50 m = 50 m rm Tk. 1,020.00
27.42.2 From 50 m to 100 m = 50 m rm Tk. 1,173.00
27.42.3 From 100 m to 152 m = 52 m rm Tk. 1,349.00
27.42.4 From 152 m to 200 m = 48 m rm Tk. 1,551.00
27.42.5 From 200 m to 250 m = 50 m rm Tk. 1,783.00
PWD SoR 2014 for Civil Works 179
27.43.3 150 mm dia strainer of slot opening as per design including tagging 4 Nos. 12 mm
dia M.S. rod continuously.
27.43.3.1 Stainless steel strainer of continuous slot having weight 28.84 kg per meter. rm Tk. 14,871.00
27.43.3.2 2.50 mm thick stainless steel Bridge type strainer. rm Tk. 10,700.00
27.43.4 150 mm x 300 mm dia M.S. reducer of minimum thickness of 6 mm. rm Tk. 3,510.00
27.43.5 300 mm dia 6 mm minimum thick M.S. housing pipe (Welded) each Tk. 6,197.00
27.43.6 300 mm dia 6 mm minimum thick M.S. housing pipe (Seamless) rm Tk. 9,970.00
27.43.7 Centralizer made with 12 mm dia M.S. rod of approved design. each Tk. 364.00
27.43.8 350 mm dia M.S. cap having 6 mm thick for housing pipe covering. each Tk. 2,036.00
27.44 Complete installation of 150 mm dia deep tube-well fixtures such as expanded rm Tk. 351.00
top pipes, reducer, tube-well pipes, strainer, blind pipe, pipe cap etc. fitting and fixing
socket, welding and additional welding with fibre and placing in position with proper
size M.S. centralizer @ 3 meter c/c in strainer portion including. blind pipe etc.
complete as per standard practice and accepted by the Engineer.
27.45 Complete development of the tube well by suitable air compressor and pump of
suitable capacity by alternate surging and pumping until satisfactory yield, sand free
water and the turbidity condition is reached using necessary quantity of calgon and
conducting step draw down test before and after the development as per
specification and accepted by the Engineer. (Development should be started within
24 hours of completion of shrouding)
27.46 Pumping test of the well by designed turbine/submersible pump with supply of hour Tk. 1,002.00
testing equipments for pressure/ velocity/ discharge etc. and all materials for 72
hours including yield drawn and recovery test etc. complete as per specification and
accepted by the Engineer.
PWD SoR 2014 for Civil Works 180
27.47 Disinfections of the well including supply of sufficient quantity of bleaching powder each Tk. 1,935.00
(33% strength) chlorinated water having 150 ppm available free chlorine etc.
complete as per standard specification and accepted by the Engineer.
27.48 Filling of the borehole around the tube well from top of the shrouding up to the rm Tk. 43.00
bottom of sanitary seal by withdrawn selected soil or local clay free from any
substances harmful to pipes and health as per standard specification and accepted
by the Engineer.
27.49 Boring: Execution of 800 mm dia boring through all sorts of strata by reverse
circulation or any other approved method (Method other than reverse circulation is
to be applied only for wells deeper than 152 meter). For boring 800 mm dia vertical
hole up to designed depth and collection of soil samples at every 3 meter interval
and at every change of formation including sinking and withdrawing necessary
casing pipe and all necessary arrangements complete as per specification and
accepted by the Engineer. (Measurement will be allowed form G.L. to bottom of the
blind pipe and the rate is required for caving and siltation)
27.50 Supplying the following tube-well fixtures and pipes conforming to standard BS-
1387 & BDS-1031, having chemical composition (in%) Carbon 0.17-0.25,
Manganese 0.95-1.20, Sulphur 0.060 max, Phosphorous 0.060 max, Tensile
properties: miminum Yield Strength 188 MPa, minimumTensile Strength 313 MPa
and marking for a) Manufacturer b) Material c) Wall thickness d) Nominal outside dia
e) Intended use etc. on the body of the pipe at working site as per standard practice
and accepted by the Engineer.
27.50.1 200 mm dia M.S. cap 6mm thick for blind pipe/ sand strap each Tk. 1,581.00
27.50.2 200 mm dia 6 mm thick tube well pipe and blank G.I. pipe of wt. 33.45 kg per meter rm Tk. 7,005.00
can withstand minimum 700 psi hydraulic pressure
27.50.3 200 mm dia strainer of slot opening as per design including tagging 4 Nos. 12 mm
dia M.S. rod continuously.
27.50.3.1 200 mm dia stainless steel strainer of continuous slot having 38.36 kg per meter. rm Tk. 16,973.00
PWD SoR 2014 for Civil Works 181
27.50.3.2 200 mm dia 2.5 mm thick stainless steel bridge type strainer rm Tk. 10,940.00
27.50.5 400 mm dia 6 mm thick M.S. housing pipe (Welded) each Tk. 10,977.00
27.50.6 400 mm dia 6 mm thick M.S. housing pipe (Seamless) rm Tk. 13,409.00
27.50.7 Centralizer made with 12 mm dia M.S. rod of approved design each Tk. 364.00
27.50.8 450 mm dia M.S. cap of 6 mm thick for housing pipe covering. each Tk. 1,977.00
27.51 Complete installation of 200 mm dia deep tube well fixtures such as expanded rm Tk. 383.00
top pipes, reducer, and tube well pipes, strainer, blind pipe. Pipe cap etc. Fitting and
fixing socket, welding and additional welding with fibre and placing in position with
proper size M.S. centralizer @ 3 meter c/c in strainer position including blind pipe
etc. complete as per standard practice and accepted by the Engineer.
27.52 Complete development of the tube well by suitable air compressor and pump of
suitable capacity by alternate surging and pumping until satisfactory yield, sand free
water and the turbidity condition is reached using necessary quantity of calgon and
conducting step draw down test before and after the development as per
specification and accepted by the Engineer. (Development should be started within
24 hours of completion of shrouding).
27.53 Pumping test of the well by designed turbine/submersible pump with supply of testing hour Tk. 1,044.00
equipments for pressure/ velocity/ discharge etc. and all materials for 72 hours
including yield drawn and recovery test etc. complete as per specification and
accepted by the Engineer.
27.54 Disinfections of the well including supply of sufficient quantity of bleaching powder each Tk. 2,211.00
(33% strength) chlorinated water having 150 ppm available free chlorine complete as
per standard specification and accepted by the Engineer.
27.55 Filling of the borehole around the tube well from top of the shrouding up to the rm Tk. 43.00
bottom of sanitary seal by withdrawn selected soil or local clay free from any
substances harmful to pipes and health as per standard specification and accepted
by the Engineer.
PWD SoR 2014 for Civil Works 182
27.56 Boring: Execution of 325 mm dia boring through all sorts of strata by reverse
circulation or any other approved method (Method other than reverse circulation is to
be applied only for wells deeper than 152 meter) for boring 325 mm dia vertical hole
up to designed depth and collection of soil samples at every 3 meter interval and at
every change of formation including sinking and withdrawing necessary casing pipe
and all necessary arrangements complete as per specification and accepted by the
Engineer.(Measurement will be allowed from G.L. to bottom of the blind pipe and the
rate is inclusive of the cost of extra depth of boring required for caving and siltation)
27.57 Supplying the following tube-well fixtures and pipes conforming to standard BS-
1387 & BDS-1031, having chemical composition (in%) Carbon 0.17-0.25,
Manganese 0.95-1.20, Sulphur 0.060 max, Phosphorous 0.060 max, Tensile
properties: miminum Yield Strength 188 MPa, minimumTensile Strength 313 MPa
and marking for a) Manufacturer b) Material c) Wall thickness d) Nominal outside dia
e) Intended use etc. on the body of the pipe at working site as per standard practice
and accepted by the Engineer.
27.57.1 150 mm dia 6mm thick M.S. cap for blind pipe/ sand trap. each Tk. 1,213.00
27.57.2 50 mm dia 4.85 mm thick tube well pipe and blank G.I. pipe rm Tk. 851.00
27.57.3 50 mm dia strainer of slot opening as per design including tagging 4 Nos. 12 mm dia
M.S. rod continuously.
27.57.3.1 50 mm dia stainless steel strainer of continuous slot having 28.84 kg per meter. rm Tk. 5,782.00
27.57.3.2 50 mm dia 2.5 mm thick stainless steel bridge type strainer rm Tk. 5,782.00
27.57.5 150 mm dia 6 mm thick M.S. housing pipe (Welded). each Tk. 3,210.00
27.57.6 150 mm dia 6 mm thick M.S. housing pipe (Seamless). rm Tk. 3,317.00
27.57.7 Centralizer made with 12 mm dia M.S. rod of approved design. each Tk. 364.00
27.57.8 150 mm dia M.S. cap of 6 mm thick for housing pipe covering. each Tk. 1,542.00
PWD SoR 2014 for Civil Works 183
27.58 Complete installation of 50 mm dia deep tube-well fixtures such as expanded rm Tk. 351.00
top pipes, reducer, tube-well pipes, strainer, blind pipe, pipe cap etc. fitting and fixing
socket, welding and additional welding with fibre and placing in position with proper
size M.S.centralizer @ 3 meter c/c in strainer portion including. blind pipe etc.
complete as per standard practice and accepted by the Engineer
27.59 Compete development of the tube well by suitable air compressor and pump of
suitable capacity by alternate surging and pumping until satisfactory yield, sand free
water and the turbidity condition is reached using necessary quantity of calgon and
conducting step draw down test before and after the development as per
specification and accepted by the Engineer. (Development should be started within
24 hours of completion of shrouding)
27.60 Pumping test of the well by designed turbine/submersible pump with supply of hour Tk. 839.00
testing equipments for pressure/ velocity/ discharge etc. and all materials for 72
hours including yield drawn and recovery test etc. complete as per specification and
accepted by the Engineer.
27.61 Disinfections of the well including supply of sufficient quantity of bleaching powder each Tk. 1,106.00
(33% strength) chlorinated water having 150 ppm available free chlorine etc.
complete as per standard specification and accepted by the Engineer.
27.62 Filling of the borehole around the tube well from top of the shrouding up to the rm Tk. 25.00
bottom of sanitary seal by withdrawn selected soil or local clay free from any
substances harmful to pipes and health as per standard specification and accepted
by the Engineer.
27.63 Boring: Execution of 350 mm dia boring through all sorts of strata by reverse
circulation or any other approved method (Method other than reverse circulation is to
be applied only for wells deeper than 152 meter) for boring 350 mm dia vertical hole
up to designed depth and collection of soil samples at every 3 meter interval and at
every change of formation including sinking and withdrawing necessary casing pipe
and all necessary arrangements complete as per specification and accepted by the
Engineer. (Measurement will be allowed from G.L. to bottom of the blind pipe and the
rate is inclusive of the cost of extra depth of boring required for caving and siltation)
27.64 Supplying the following tube-well fixtures and pipes conforming to standard BS-
1387 & BDS-1031, having chemical composition (in%) Carbon 0.17-0.25,
Manganese 0.95-1.20, Sulphur 0.060 max, Phosphorous 0.060 max, Tensile
properties: miminum Yield Strength 188 MPa, minimumTensile Strength 313 MPa
and marking for a) Manufacturer b) Material c) Wall thickness d) Nominal outside dia
e) Intended use etc. on the body of the pipe at working site as per standard practice
and accepted by the Engineer.
27.64.1 150 mm dia 6mm thick M.S. cap for blind pipe/ sand trap. each Tk. 1,209.00
27.64.2 75 mm dia 4.85 mm thick tube well pipe and blank G.I. pipe rm Tk. 1,328.00
27.64.3 75 mm dia strainer of slot opening as per design including tagging 4 Nos. 12 mm dia
M.S. rod continuously.
27.64.3.1 75 mm dia stainless steel strainer of continuous slot having 28.84 kg per meter. rm Tk. 7,753.00
27.64.3.2 75 mm dia 2.5 mm thick stainless steel bridge type strainer rm Tk. 7,753.00
27.64.5 150 mm dia 6 mm thick M.S. housing pipe (Welded) each Tk. 3,210.00
27.64.6 150 mm dia 6 mm thick M.S. housing pipe (Seamless) each Tk. 3,317.00
27.64.7 Centralizer made with 12 mm dia M.S. rod of approved design each Tk. 364.00
27.64.8 150 mm dia M.S. cap of 6 mm thick for housing pipe covering. rm Tk. 1,542.00
27.65 Complete installation of 75 mm dia deep tube-well fixtures such as expanded rm Tk. 341.00
top pipes, reducer, tube-well pipes, strainer, blind pipe, pipe cap etc. fitting and fixing
socket, welding and additional welding with fibre and placing in position with proper
size M.S. centralizer @ 3 meter c/c in strainer portion including blind pipe etc.
complete as per standard practice and accepted by the Engineer.
27.66 Complete development of the tube well by suitable air compressor and pump of
suitable capacity by alternate surging and pumping until satisfactory yield, sand free
water and the turbidity condition is reached using necessary quantity of calgon and
conducting step draw down test before and after the development as per
specification and accepted by the Engineer. (Development should be started within
24 hours of completion of shrouding)
27.67 Pumping test of the well by designed turbine/submersible pump with supply of hour Tk. 897.00
testing equipments for pressure/ velocity/ discharge etc. and all materials for 72
hours including yield drawn and recovery test etc. complete as per specification and
accepted by the Engineer.
27.68 Disinfections of the well including supply of sufficient quantity of bleaching powder each Tk. 1,342.00
(33% strength) chlorinated water having 150 ppm available free chlorine etc.
complete as per standard specification and accepted by the Engineer.
27.69 Filling of the borehole around the tube well from top of the shrouding up to the rm Tk. 29.00
bottom of sanitary seal by withdrawn selected soil or local clay free from any
substances harmful to pipes and health as per standard specification and accepted
by the Engineer.
27.70 Boring: Execution of 400 mm dia boring through all sorts of strata by reverse
circulation or any other approved method (Method other than reverse circulation is to
be applied only for wells deeper than 152 meter) for boring 400 mm dia vertical hole
up to designed depth and collection of soil samples at every 3 meter interval and at
every change of formation including sinking and withdrawing necessary casing pipe
and all necessary arrangements complete as per specification and accepted by the
Engineer. (Measurement will be allowed from G.L. to bottom of the blind pipe and the
rate is inclusive of the cost of extra depth of boring required for caving and siltation)
27.71 Supplying the following tube-well fixtures and pipes conforming to standard BS-
1387 & BDS-1031, having chemical composition (in%) Carbon 0.17-0.25,
Manganese 0.95-1.20, Sulphur 0.060 max, Phosphorous 0.060 max, Tensile
properties: miminum Yield Strength 188 MPa, minimumTensile Strength 313 MPa
and marking for a) Manufacturer b) Material c) Wall thickness d) Nominal outside dia
e) Intended use etc. on the body of the pipe at working site as per standard practice
and accepted by the Engineer.
27.71.1 Supplying 150 mm 6mm thick M.S. cap for blind pipe/ sand trap. each Tk. 1,213.00
27.71.2 Supplying 100 mm dia 6 mm thick tube well pipe and blank G.I. pipe rm Tk. 1,780.00
27.71.3 100 mm dia strainer of slot opening as per design including tagging 4 Nos. 12 mm
dia M.S. rod continuously.
PWD SoR 2014 for Civil Works 186
27.71.3.1 Supplying 100 mm dia stainless steel strainer of continuous slot having 28.84 kg per rm Tk. 6,994.00
meter.
27.71.3.2 Supplying 100 mm dia 2.5 mm thick stainless steel bridge type strainer rm Tk. 6,994.00
27.71.4 Supplying 100 mm x 200 mm dia 6 mm thick M.S. reducer. rm Tk. 5,626.00
27.71.5 Supplying 200 mm dia 6 mm thick M.S. housing pipe (Welded) each Tk. 3,631.00
27.71.6 Supplying 200 mm dia 6 mm thick M.S. housing pipe (Seamless) rm Tk. 3,992.00
27.71.7 Supplying centralizer made with 12 mm dia M.S. rod of approved design each Tk. 210.00
27.71.8 Supplying 200 mm dia M.S. cap of 6 mm thick for housing pipe covering. each Tk. 2,150.00
27.72 Complete installation of 100 mm dia deep tube-well fixtures such as expanded rm Tk. 383.00
top pipes, reducer, and tube-well pipes, strainer, blind pipe, pipe cap etc. fitting and
fixing socket, welding and additional welding with fibre and placing in position with
proper size M.S. centralizer @ 3 meter c/c in strainer portion including blind pipe etc.
complete as per standard practice and accepted by the Engineer.
27.73 Complete development of the tube well by suitable air compressor and pump of
suitable capacity by alternate surging and pumping until satisfactory yield, sand free
water and the turbidity condition is reached using necessary quantity of calgon and
conducting step draw down test before and after the development as per
specification and accepted by the Engineer. (Development should be started within
24 hours of completion of shrouding)
27.74 Pumping test of the well by designed turbine/submersible pump with supply of hour Tk. 939.00
testing equipments for pressure/ velocity/ discharge etc. and all materials for 72
hours including yield drawn and recovery test etc. complete as per specification and
accepted by the Engineer.
27.75 Disinfections of the well including supply of sufficient quantity of bleaching powder each Tk. 1,579.00
(33% strength) chlorinated water having 150 ppm available free chlorine etc.
complete as per standard specification and accepted by the Engineer.
27.76 Filling of the borehole around the tube well from top of the shrouding up to the rm Tk. 32.00
bottom of sanitary seal by withdrawn selected soil or local clay free from any
substances harmful to pipes and health as per standard specification and accepted
by the Engineer.
27.77 Supplying and sinking 40 mm dia water grade uPVC tube well pipe having wall
thickness 2.5 mm to 3.0 mm including trial boring and with all necessary fittings as
required etc. all complete and accepted by the Engineer.
27.78 Supplying and sinking 3 m long uPVC strainer with all necessary fittings as each Tk. 486.00
required etc. complete and accepted by the Engineer.
27.79 Supplying, fitting and fixing No. 6 pump for 40 mm dia tube well with all each Tk. 931.00
necessary fittings including 0.61 m long 40 mm dia G.I. Pipe etc. all complete as per
accepted by the Engineer.
27.80 Construction of platform of size 1.4 m x 1.0 m and outlet drain up to1 meter long, each Tk. 4,552.00
as per drawing with 75 mm thick cement concrete of f'c min17MPa with brick chips
and cement content relates to 1:2:4, over a brick flat soling and providing 125 mm x
75mm brick band in 1:6 all around, including finished with 12 mm thick cement
plaster in 1:4 followd by neat cement finishing all complete and accepted by the
Engineer.
27.81 Supplying and sinking uPVC, uPVC tube well pipe, strainer including trial boring
having density 1350 kg/m3, opacity 0.2% of visible light as per ISO 7686, minimum
required strength 25 MPa conforming to BDS-1:2013, 4.4.1, 4.4.2 with all necessary
fittings as required etc. all complete and accepted by the Engineer.
27.81.1 50 mm dia water grade uPVC pipe having wall thickness 2.5 mm to 3 mm rm Tk. 405.00
27.81.2 40 mm dia water grade uPVC pipe having wall thickness 2.5 mm to 3 mm rm Tk. 225.00
27.82 Supplying, fitting and fixing deep set tube well pump (Hand set) with all necessary each Tk. 5,808.00
fittings as required such as No. 6 pump, 50 mm dia G.I. pipe 0.61 m long, 50 mm x
40 mm reducing socket, 40 mm dia pipe Nipple 1.22 m long cylinder, Tie foot ball, tie
plunger, 3 Nos. 10 mm dia socket, 4 Nos. 10mm dia nuts, 5 Nos. end threaded 10
mm dia M.S. rod 3 m long, necessary quantity of solution and tape etc. complete and
accepted by the Engineer.
28.1 Pipe line installation: Installation of 50 psi, APl, 5L, Grade-B, ERW Natural pipe line
for supplying Titas Gas including, supplying, fitting, fixing and laying different sizes
M.S. pipes with necessary tape and primer including. cutting trenches (450 x 910
mm) in all kinds of soil, cleaning, cutting, applying coal-tar, wrapping the pipes and
back filling the trenches, excavating earth including. leveling, dressing and removing
excess earth in all respect as per specification of Titas Gas T and D Co. Ltd. and
accepted by the Engineer.[Rate is excluding the cost of welding and back filling with
sand at the bottom by 300 mm in thick (compacted)]
(Pipes manufactured by National Tubes Limited under Steel & Engineeing Corporation, Ministry of
Industries, Government of Bangladesh shall be given priority)
28.1.1 75 mm N.D (88.90 mm O.D) M.S pipe, weight min 8.3 kg/m, standard test pressure rm Tk. 1,509.00
176 kg/ m2, wall thickness min 11.29 mm
28.1.2 50 mm N.D. (60.30 mm O.D) M.S pipe, weight min 5.44 kg/m, standard test pressure rm Tk. 972.00
176 kg/ m2, wall thickness min 3.91 mm
28.1.3 25 mm N.D. (33.40 mm O.D) M.S pipe weight min 2.50 kg/m, standard test pressure rm Tk. 728.00
50 kg/ m2, wall thickness min 3.38 mm
28.1.4 20 mm N.D. (26.70 mm O.D) M.S pipe weight min 1.68 kg/m, standard test pressure rm Tk. 418.00
50 kg/ m2, wall thickness min 2.87 mm
28.2 Back filling the trenches with sand (F.M 0.8) in 150 mm layer, compaction each cum Tk. 644.00
layer up to finished level as per standard practice and accepted by the Engineer.
28.3 Providing Butt welded joints with pipes to Tees, Elbows, Saddles, end caps etc
above or below ground including. cutting and V-leveling in each end of the pipe,
grinding by machine etc. complete as per specification of Titas Gas T and D C Ltd.
and accepted by the Engineer.
28.4 Supplying, fitting and fixing the following materials including carriage to the work site
from Titas Gas Store as per specification of Titas Gas (T and D) Co. Ltd. and
accepted by the Engineer. (Rate is excluding the cost of welding)
28.5 Supplying, welding, fitting and fixing of different sizes Valve Tee/ Service Tee to
connect the pipe line with the Titas Gas Main pipe line etc. all complete in all respect
as per specification of Titas Gas T and D Co. Ltd. approved and accepted by the
Engineer.
28.5.1 50 mm x 50 mm Valve Tee (2" and above 2" low pressure line) each Tk. 20,427.00
28.6 Supplying, fitting and fixing in position different dia I/F (Insulated Flange) etc .all each Tk. 6,609.00
complete in all respect as per specification of Titas Gas T and D Co. Ltd. approved
and accepted by the Engineer. 50 mm N.D. (60.30 mm O.D) Insulation Flange.
28.7 Construction of 1520 x 1520 x 1370 (depth) mm water-tight valve pit, enclosed by each Tk. 63,844.00
250 mm thick brick wall in 1:6, plastered on each face in 1:4 with net cement
finishing, having a 75 mm thick C.C (1:3:6) bed upon a layer of brick flat soling, over
laid by 38 mm thick patent stone flooring including standard M.S. sheet valve pit
cover as per drawing and specification of Titas Gas T and D Co. Ltd. etc. all
complete in all respect and accepted by the Engineer.
28.8 Testing and purging the pipe lines properly as per specification of Titas Gas T and rm Tk. 24.00
D Co. Ltd. and accepted by the Engineer.
28.9 Supplying, fitting and fixing ball valve class 150 RF including supplying of 2 Nos.
flange along with necessary nuts and bolts welding the flange etc. all complete in all
respect as per specification of Titas Gas T and D Co. Ltd. approved and accepted by
the Engineer
28.9.1 50 mm ball valve class 150 RF. 2" dia each Tk. 15,511.00
28.9.2 25 mm ball valve class 150 RF.1" dia each Tk. 10,243.00
28.10 Cutting permanent pucca (rigid/flexible) road and mending good the damages
etc. all complete in all respect and accepted by the Engineer.
PWD SoR 2014 for Civil Works 190
28.11 Installation of Domestic or Commercial House line for supplying Titas Gas
including supplying, fitting and fixing in position different dia best quality G.I. Pipe
(NT or equivalent) along with all necessary G.I. Fitting and accessories, cutting
trenches, walls and floors etc. and back filling the trenches, restoring walls and floors
etc. all complete in all respect as per specification of Titas Gas T and D Co. Ltd. and
accepted by the Engineer.
28.12 Supplying, fitting and fixing in position different dia one-way brass stop cock (best
quality and heavy type) etc. complete in all respect as per specification of Titas Gas
T and D Co. Ltd. approved and accepted by the Engineer.
28.13 Testing and purging the house line properly as per specifications Titas Gas T and rm Tk. 16.00
D Co. Ltd. and accepted by the Engineer.
29.1 Supplying anti-termite chemicals named DURS BAN 20 EC and mixing the same sqm Tk. 204.00
with pure water in required proportion (For DURSBAN 20 EC I Ltd. in 19 liters of
pure water) and spraying the emulsified mixture @ 5 liters per square meter of soil
surface by chemical sprayer or by any other means to the sides and bottom of the
foundation trench and over plinth filling or floor bed accepted by the Engineer.
29.2 Extra cost for supplying anti termite chemicals named DURS BAN 20 EC and cum Tk. 1,501.00
mixing the same with pure water as per specification in item No. 1 and using the
same emulsified water as mixing water in cement-sand mortar of brick works in
foundation and up to plinth and accepted by the Engineer.
29.3 Supplying anti-termite chemicals named DURS BAN 20 EC and mixing the same sqm Tk. 305.00
with pure water as per specification in item No. 1 and spraying the emulsified mixture
with hand sprayer over both outside and inside back fill in foundation trenches
@ 7.50 liters per sqm of the vertical surface area of the foundation wall accepted by
the Engineer. (The maximum depth of the back fill to be treated is 500 mm. and the
measurement for depth should not be given more than 500 mm)
29.4 Anti-termite treatment in existing super structures by making downwardly Per Tk. 39.00
slanting holes at a required depth of 9" from the existing finished F.L/G.L inside and hole
outside the building and applying the emulsion of anti termite chemicals, named
DURS BAN 20 EC into the holes preparing chemical solution mixing with water at the
ratio of chemical: water = 1:19 maintaining a dosage rate of 250 ml per hole
including supplying all materials and repairing the holes all complete and accepted
by the Engineer.
29.5 Trench treatment for protection against incoming termites to the establishment rm Tk. 202.00
through underground by making trench around existing building /structures at a
required depth of 750 mm from existing level supplying anti-termite chemicals named
DURS BAN 20 EC preparing the solution to be mixed with water in the ratio of
chemical: water = 1:19 applying the solution into trench with the help of a chemical
sprayer in three layers and each layer follows a 250 mm thick back-fill in trench etc
all complete and accepted by the Engineer.
29.6 Fumigation treatment (Pest Control) against mosquitoes, flies, bees, cockroaches, cum Tk. 15.00
spiders, silver fishes, lizards and other common pests and insects in wooden walls,
bricks walls, floors, doors and windows, furniture fanlight, carpets, records, curtains,
electrical conduits etc. with the application of fumigants such as Syngeata or
NEOCIDOL-60 EC or similar chemically equivalent govt. registered pest control
products preparing chemical solution mixing with water in the ratio of chemical: water
= 1:100 applying with the help of electrically/mechanically operated jet fogging
machine, swing fog, dyna fog, pneumatic hand sprayer, knap sac hand sprayer in
air-tight position, After fumigation the surface will be kept remain at air-tight condition
at least for 3 (three) hours etc. complete and accepted by the Engineer.
(Volume of the room will be considered towards measurement.)
29.7 Anti termite treatment of all wooden doorframes, window frames, wood sqm Tk. 148.00
paneling etc by using DURS BAN 20 EC emulsion in the ratio of 1 liter. DURS BAN
20 EC + 19 liters of Kerosene oil suitable for wood, plywood, particle board, hard
board etc. on both surfaces by brush on both surfaces by brush-on-method etc.
complete and accepted by the Engineer.
PWD SoR 2014 for Civil Works 192
29.8 Anti-termite treatment of electric telephone wiring system by inserting a plugging Per Tk. 235.00
materials (cotton, foam etc.) soaked in anti-termite chemical DURS BAN 20 EC to an board
electric switch board point for all floors and spraying the emulsion (to be mixed at the
ratio of 1 liters DURS BAN 20 EC + 19 liter of water) to the casings and grooving of
electric wirings, telephone cables utility pipes etc. for all floors etc. complete and
accepted by the Engineer.
29.9 Destruction of termite nest around an infested building, tree stumps in lawn with the each Tk. 1,474.00
treatment of DURS BAN 20 EC by excavation of soil in affected area up to a depth of nest
1.5 meter, mixing the DURS BAN 20 EC solution to be mixed with water in 1:19 ratio
with the soil and laying the same in same place etc. all complete as per direction
including. cost of all materials and chemicals etc. complete and accepted by the
Engineer.
30.1 70 mm thick partition wall excluding plaster thickness with Concrete Hollow block
having compressive strength of 4.14~5N/mm2 of size (390 x 70 x 190) mm in
compliance with ASTM C129, fairly uniform thickness and texture and individual
Block shell thickness should not be less than 16 mm, water absorption not more than
7%, laying with 8-10 mm thick mortar (with admixture) of cement, lime and sand
in ratio 1:1:6 (sand not less than 1.2 F.M) filling the interstices with mortar and
making bond with connecting walls including necessary scaffolding and curing for
min 3 (three) days on mortar joints by jute /brush in wet, followed by impervious /wet
covering for another 4 (four) days etc all complete and accepted by the Engineer.
30.1.2 Add for each addl. floor up to 5th floor sqm Tk. 24.82
30.1.3 Add for each addl floor for 6th floor to 9th floor sqm Tk. 33.10
30.1.4 Add for each addl floor for 10th floor and above sqm Tk. 41.37
30.2 70 mm thick partition wall excluding plaster thickness with Concrete Hollow block
having compressive strength of 4.14~5N/mm 2 of size (390 x 70 x 190) mm
compliance with ASTM C129, thickness of individual Block shell should not be less
than 16 mm, water absorption not more then 7 % lying with 8 to 10 mm thick mortar
(with admixture) of cement and sand in ratio 1:6 (sand not less than 1.2 F.M)
filling the interstices with mortar and making bond with connecting walls including
necessary scaffolding and curing for min 3(three) days on mortar joints by jute/brush
in wet, followed by impervious/wet covering for another 4 (four) days etc all complete
and accepted by the Engineer.
30.2.2 Add for each addl. floor up to 5th floor sqm Tk. 24.82
30.2.3 Add for each addl floor for 6th floor to 9th floor sqm Tk. 33.10
30.2.4 Add for each addl floor for 10th floor and above sqm Tk. 41.37
30.3 90 mm thick partition wall with Concrete Hollow block having strength of
4.14~5N/mm2 of size (390 x 90 x 190) mm in compliance with ASTM C129, thickness
of individual Block shell should not be less than 16 mm, water absorption not more
then 7%, lying with specified mortar (with admixture) of cement, lime and sand in
ratio 1:1:6 (sand not less than 1.2 F.M), filling the interstices with mortar and making
bond with connecting walls including necessary scaffolding and curing for min 3
(three) days on mortar joints by jute /brush in wet, followed by impervious /wet
covering for another 4( four) days curing etc all complete and accepted by the
Engineer.
30.3.2 Add for each addl. floor up to 5th floor sqm Tk. 24.82
PWD SoR 2014 for Civil Works 194
30.3.3 Add for each addl floor for 6th floor to 9th floor sqm Tk. 33.10
30.3.4 Add for each addl floor for 10th floor and above sqm Tk. 41.37
30.4 90 mm thick partition wall with Concrete Hollow block having compressive strength
of 4.14~5N/mm2 of size (390 x 90 x 190) mm in compliance with ASTM C129,
thickness of individual Block shell should not be less than 16 mm, water absorption
not more than 7%, lying with specified mortar (with admixture) of cement, and
sand in ratio 1:6 (sand not less than 1.2 F.M), filling the interstices with mortar and
making bond with connecting walls including necessary scaffolding and curing for
min 3 (three) days on mortar joints by jute /brush in wet, followed by impervious /wet
covering for another 4 (four) days curing etc. all complete and accepted by the
Engineer.
30.4.2 Add for each addl. floor up to 5th floor sqm Tk. 24.82
30.4.3 Add for each addl floor for 6th floor to 9th floor sqm Tk. 33.10
30.4.4 Add for each addl floor for 10th floor and above sqm Tk. 41.37
30.5 140 mm thick load bearing wall with Concrete Hollow block having compressive
strength of 13~18N/mm2 of size (390 x 140 x 190) mm compliance with ASTM C90,
thickness of individual Block shell should not be less then 25 mm, water absorption
not more than 7%, laying with mortar (with admixture) of cement, lime and sand
in ratio 1:1:6 (sand not less than 1.2 F.M), filling the interstices with mortar and
making bond with connecting walls including necessary scaffolding and curing for
min 3 (three) days on mortar joints by jute /brush in wet, followed by impervious /wet
covering for another 4 (four) days etc all complete and accepted by the Engineer.
30.5.2 Add for each addl. floor up to 5th floor sqm Tk. 33.10
30.5.3 Add for each addl floor for 6th floor to 9th floor sqm Tk. 41.37
30.5.4 Add for each addl floor for 10th floor and above sqm Tk. 49.65
30.6 140 mm thick partition wall with Concrete Hollow block having compressive
strength of 4.14~5N/mm2 of size (390 x 140 x 190) mm in compliance with ASTM
C129, thickness of individual Block shell should not be less than 16 mm, water
absorption not more than 7%, laying with specified mortar (with admixture) of
cement and sand in ratio 1:6 (sand not less than 1.2 F.M), filling the interstices with
mortar and making bond with connecting walls including necessary scaffolding and
curing for min 3 (three) days on mortar joints by jute /brush in wet, followed by
impervious /wet covering for another 4( four) days curing etc all complete and
accepted by the Engineer.
30.6.2 Add for each addl. floor up to 5th floor sqm Tk. 33.10
30.6.3 Add for each addl floor for 6th floor to 9th floor sqm Tk. 41.37
30.6.4 Add for each addl floor for 10th floor and above sqm Tk. 49.65
PWD SoR 2014 for Civil Works 195
30.7 140 mm thick load bearing wall with Concrete Hollow block having compressive
strength of 13~18N/mm2 of size (390 x 140 x 190) mm compliance with ASTM C90,
thickness of individual Block shell should not be less then 25 mm, water absorption
not more than 7%, laying with mortar (with admixture) of cement, lime and sand
in ratio 1:1:6 (sand not less than 1.2 F.M), filling the interstices with mortar and
making bond with connecting walls including necessary scaffolding and curing for
min 3 (three) days on mortar joints by jute /brush in wet, followed by impervious /wet
covering for another 4 (four) days etc all complete and accepted by the Engineer.
30.7.2 Add for each addl. floor up to 5th floor sqm Tk. 33.10
30.7.3 Add for each addl floor for 6th floor to 9th floor sqm Tk. 41.37
30.7.4 Add for each addl floor for 10th floor and above sqm Tk. 49.65
30.8 140 mm thick load bearing wall with Concrete Hollow block having compressive
strength of 13~18 N/mm2 of size (390 x140 x 190) mm in compliance with ASTM
C90, thickness of individual Block shell should not be less than 25 mm, water
absorption not more than 7%, laying with mortar (with admixture) of cement and
sand in ratio 1:6 (sand not less than 1.2 F.M), filling the interstices with mortar and
making bond with connecting walls including necessary scaffolding and curing for
min 3 (three) days on mortar joints by jute /brush in wet, followed by impervious /wet
covering for another 4 (four) days etc all complete and accepted by the Engineer.
(rate is excluding the cost of grouting and reinforcement)
30.8.2 Add for each addl. floor up to 5th floor sqm Tk. 33.10
30.8.3 Add for each addl floor for 6th floor to 9th floor sqm Tk. 41.37
30.8.4 Add for each addl floor for 10th floor and above sqm Tk. 49.65
30.9 190 mm thick load bearing wall with Concrete Hollow block having compressive
strength of 4.14~5 N/mm2 of size (390 x 190 x 190) mm compliance with ASTM C90,
thickness of individual Block shell should not be less than 25 mm, water absorption
not more than 7%, laying with mortar (with admixture) of cement, lime and sand
in ratio 1:1:6 (sand not less than 1.2 F.M), filling the interstices with mortar and
making bond with connecting walls including necessary scaffolding and curing for
min 3 (three) days on mortar joints by jute /brush in wet, followed by impervious /wet
covering for another 4 (four) days etc all complete and accepted by the Engineer.
(rate is excluding the cost of grouting and reinforcement)
30.9.2 Add for each addl. floor up to 5th floor sqm Tk. 41.37
30.9.3 Add for each addl floor for 6th floor to 9th floor sqm Tk. 49.65
30.9.4 Add for each addl floor for 10th floor and above sqm Tk. 57.92
PWD SoR 2014 for Civil Works 196
30.10 190 mm thick load bearing wall with Concrete Hollow block having compressive
strength of 13~18 N/mm2 of size (390 x 190 x 190) mm in compliance with ASTM
C90, thickness of individual block shell should not be less than 25 mm, water
absorption not more than 7%, laying with mortar (with admixture) of cement and
sand in ratio 1:6 (sand not less than 1.2 F.M), filling the interstices with mortar and
making bond with connecting walls including necessary scaffolding and curing for
min 3 (three) days on mortar joints by jute /brush in wet, followed by impervious /wet
covering for another 4 (four) days etc all complete and accepted by the Engineer.
(Rate is excluding cost of grouting and reinforcement)
30.10.2 Add for each addl. floor up to 5th floor sqm Tk. 41.37
30.10.3 Add for each addl floor for 6th floor to 9th floor sqm Tk. 49.65
30.10.4 Add for each addl floor for 10th floor and above sqm Tk. 57.92
30.11 Supplying, carrying and placing of (600 x 200 x 150) mm concrete ceiling block on
properly leveled shutter accepted by the Engineer.
30.11.2 Add for each addl. floor up to 5th floor each Tk. 3.08
30.11.3 Add for each addl floor for 6th floor to 9th floor each Tk. 3.84
30.11.4 Add for each addl floor for 10th floor and above each Tk. 4.61
30.12 Supplying, carrying and placing of (600 x 200 x200) mm concrete ceiling block on
properly leveled shutter accepted by the Engineer
30.12.2 Add for each addl. floor up to 5th floor each Tk. 3.84
30.12.3 Add for each addl floor for 6th floor to 9th floor each Tk. 6.92
30.12.4 Add for each addl floor for 10th floor and above each Tk. 8.07
30.13 Minimum 10 mm thick cement plaster in cement : sand (1:5) in outer surface of
external wall with specified external plaster mix applied in two coats (first coat 6/7
mm and second coat 4/3 mm) finishing the corner and edge including washing of
sand cleaning the surface, scaffolding and curing for min 3 (three) days on mortar
joints by jute/brush in wet, followed by impervious/wet covering for another 4 (four)
days etc. all complete etc. all complete and accepted by the Engineer. (Rate is
excluding cost of grouting and reinforcement)
30.13.2 Add for each addl. floor up to 5th floor sqm Tk. 11.03
30.13.3 Add for each addl floor for 6th floor to 9th floor sqm Tk. 16.55
30.13.4 Add for each addl floor for 10th floor and above sqm Tk. 22.07
PWD SoR 2014 for Civil Works 197
30.14.1 Supplying and placing of approx. 60 mm thick grey Uni-Block paving for walk way sqm Tk. 799.00
having compressive strength of 15 N/mm 2 on compacted sand bed of 50 mm on
stabilized soil base, and filling all interstices with sand, cleaning etc. accepted by the
Engineer.
30.14.2 Supplying and placing of approx. 60 mm thick coloured Uni-Block for paving walk sqm Tk. 1,019.00
way having compressive strength of 15 N/mm2 on compacted sand bed of 50 mm on
stabilized soil base, and filling all interstices with sand, cleaning etc. accepted by the
Engineer.
30.15.1 Supplying and placing of 60 mm thick grey Uni-Block for paving foot-path, major sqm Tk. 1,081.00
walk way, car porch having compressive strength of 49 N/mm2 on compacted sand
bed of 50 mm on stabilized soil base, and filling all interstices with sand, cleaning
etc. accepted by the Engineer.
30.15.2 Supplying and placing of 60 mm thick coloured Uni-Block for paving foot-path, sqm Tk. 1,155.00
major walk way, car porch having compressive strength of 49 N/mm2 on
compacted sand bed of 50 mm on stabilized soil base, and filling all interstices with
sand, cleaning etc. accepted by the Engineer.
30.16.1 Supplying and placing of 80 mm grey Uni-Block for paving Heavy Trafic areas, sqm Tk. 1,330.00
Roads Rounds Abuts, Industrial Yards etc having compressive strength of 49
N/mm2 on compacted sand bed of 50 mm on stabilized soil base, and filling all
interstices with sand, cleaning etc. accepted by the Engineer.
30.16.2 Supplying and placing of 80 mm thick coloured Uni-Block for paving Heavy trafic sqm Tk. 1,590.00
areas, road, industrial yard etc having compressive strength of 49 N/mm2 on
compacted sand bed of 50 mm on stabilized soil base, and filling all interstices with
sand, cleaning etc. accepted by the Engineer.
30.17.1 Supplying and placing of grey 200 x 100 x 60 mm Rectangular Block having sqm Tk. 1,399.00
compressive strength of 15N/mm2 on 50 mm thick compacted sand bed, and filling
all interstices with sand, cleaning etc. accepted by the Engineer.
30.17.2 Supplying and placing of coloured 200 x 100 x 60 mm Rectangular Block having sqm Tk. 1,605.00
compressive strength of 15N/mm2 on 50 mm thick compacted sand bed, and filling
all interstices with sand, cleaning etc. accepted by the Engineer.
30.18.1 Supplying and placing of grey engraved cement concrete tiles (250 x 250 mm) in
size having minimum thickness 24 mm over 12 mm sand cement mortar (4:1) each
at a distance of 6 mm apart and filling the joints with cement sand mortar (1:4)
including raking out joints and cutting the tiles to required sizes wherever necessary
with high class recessed pointing, cleaning and washing of sand, curing for min 3
(three) days on mortar joints by jute /brush in wet, followed by impervious /wet
covering for another 4 (four) days etc. all complete and accepted by the Engineer.
30.18.1.2 Add for each addl. floor up to 5th floor sqm Tk. 31.28
30.18.1.3 Add for each addl floor for 6th floor to 9th floor sqm Tk. 39.10
30.18.1.4 Add for each addl floor for 10th floor and above sqm Tk. 46.92
PWD SoR 2014 for Civil Works 198
30.18.2 Supplying and placing of coloured engraved cement concrete tiles (250 x 250
mm) in size having minimum thickness 24 mm over 12 mm sand cement mortar (4:1)
each at a distance of 6 mm apart and filling the joints with cement sand mortar (1:4)
including raking out joints and cutting the tiles to required sizes wherever necessary
with high class recessed pointing, cleaning and washing of sand, curing for min 3
(three) days on mortar joints by jute /brush in wet, followed by impervious /wet
covering for another 4 (four) days etc. all complete and accepted by the Engineer.
30.18.2.2 Add for each addl. floor up to 5th floor sqm Tk. 31.28
30.18.2.3 Add for each addl floor for 6th floor to 9th floor sqm Tk. 39.10
30.18.2.4 Add for each addl floor for 10th floor and above sqm Tk. 46.92
30.19.1 215 mm thick wall (excluding plaster thickness) with 215 x 100 x 65 mm concrete
solid block having minimum compressive strength of 21 N/mm2 of size with 6 mm
thick cement sand mortar in 1:6 in superstructure including racking out the joints,
filling the interstices with mortar and making bond with connecting walls including
necessary scaffolding and curing for min. 3 (three) days on mortar joint by jute/ brush
in wet followed by impervious covering for another 4 (four) days etc. all complete and
accepted by the Engineer.
30.19.1.2 Add for each addl. floor up to 5th floor sqm Tk. 31.28
30.19.1.3 Add for each addl floor for 6th floor to 9th floor sqm Tk. 39.10
30.19.1.4 Add for each addl floor for 10th floor and above sqm Tk. 46.92
30.19.2 100 mm thick wall (excluding plaster thickness) with 215 x 100 x 65 mm concrete
solid block having minimum compressive strength of 21N/mm2 of size with 6 mm
thick cement sand mortar in 1:6 in superstructure including racking out the joints,
filling the interstices with mortar and making bond with connecting walls including
necessary scaffolding and curing for min. 3 (three) days on mortar joint by jute/ brush
in wet followed by impervious covering for another 4 (four) days etc. all complete and
accepted by the Engineer.
30.19.2.2 Add for each addl. floor up to 5th floor sqm Tk. 31.28
30.19.2.3 Add for each addl floor for 6th floor to 9th floor sqm Tk. 39.10
30.19.2.4 Add for each addl floor for 10th floor and above sqm Tk. 46.92
30.20.1 38 mm thick Grey cladding work in facing on superstructure with (200 x 90x 38)
mm size concrete clad pested with 20 mm thick cement mortar (1:4) to be placed at
6 mm apart, filling the interstices with same mortar, raking out joints and cutting the
clad to required sizes wherever necessary with high class recessed pointing,
cleaning and washing of sand, necessary scaffolding, curing for min 3 (three) days
on mortar joints by jute /brush in wet, followed by impervious /wet covering for
another 4 (four) days etc. all complete for up to 4th floor accepted by the Engineer.
PWD SoR 2014 for Civil Works 199
30.20.1.2 Add for each addl. floor up to 5th floor sqm Tk. 31.28
30.20.1.3 Add for each addl floor for 6th floor to 9th floor sqm Tk. 39.10
30.20.1.4 Add for each addl floor for 10th floor and above sqm Tk. 46.92
30.20.2.2 Add for each addl. floor up to 5th floor sqm Tk. 31.28
30.20.2.3 Add for each addl floor for 6th floor to 9th floor sqm Tk. 39.10
30.20.2.4 Add for each addl floor for 10th floor and above sqm Tk. 46.92
30.20.3 50 mm thick Grey cladding work in facing on superstructure with (400 x100 x 50)
mm size concrete clad pested with 20 mm thick cement mortar (1:4) to be placed at
6 mm apart, filling the interstices with same mortar, raking out joints and cutting the
clad to required sizes wherever necessary with high class recessed pointing,
cleaning and washing of sand, necessary scaffolding, curing for min 3 (three) days
on mortar joints by jute /brush in wet, followed by impervious /wet covering for
another 4 (four) days etc. all complete for up to 4th floor accepted by the Engineer.
30.20.3.2 Add for each addl. floor up to 5th floor sqm Tk. 31.28
30.20.3.3 Add for each addl floor for 6th floor to 9th floor sqm Tk. 39.10
30.20.3.4 Add for each addl floor for 10th floor and above sqm Tk. 46.92
30.20.4 50 mm thick coloured cladding work in facing on superstructure with (400 x 100
X 50) mm size concrete clad pested with 20 mm thick cement mortar (1:4) to be
placed at 6 mm apart, filling the interstices with same mortar, raking out joints and
cutting the clad to required sizes wherever necessary with high class recessed
pointing, cleaning and washing of sand, necessary scaffolding, curing for min 3
(three) days on mortar joints by jute /brush in wet, followed by impervious /wet
covering for another 4 (four) days etc. all complete for up to 4th floor accepted by the
Engineer.
30.20.4.2 Add for each addl. floor up to 5th floor sqm Tk. 31.28
30.20.4.3 Add for each addl floor for 6th floor to 9th floor sqm Tk. 39.10
PWD SoR 2014 for Civil Works 200
30.20.4.4 Add for each addl floor for 10th floor and above sqm Tk. 46.92
30.20.5 15 mm thick Grey cladding work in facing on superstructure with (420 x 330 x 15)
mm size concrete clad pested with 20 mm thick cement mortar (1:4) to be placed at
6 mm apart, filling the interstices with same mortar, raking out joints and cutting the
clad to required sizes wherever necessary with high class recessed pointing,
cleaning and washing of sand, necessary scaffolding, curing for min 3 (three) days
on mortar joints by jute /brush in wet, followed by impervious /wet covering for
another 4 (four) days etc. all complete for up to 4th floor accepted by the Engineer.
30.20.5.2 Add for each addl. floor up to 5th floor sqm Tk. 31.28
30.20.5.3 Add for each addl floor for 6th floor to 9th floor sqm Tk. 39.10
30.20.5.4 Add for each addl floor for 10th floor and above sqm Tk. 46.92
30.20.6 15 mm thick coloured cladding work in facing on superstructure with (420 x 330 x
15) mm size concrete clad pested with 20 mm thick cement mortar (1:4) to be
placed at 6 mm apart, filling the interstices with same mortar, raking out joints and
cutting the clad to required sizes wherever necessary with high class recessed
pointing, cleaning and washing of sand, necessary scaffolding, curing for min 3
(three) days on mortar joints by jute /brush in wet, followed by impervious /wet
covering for another 4 (four) days etc. all complete for up to 4th floor accepted by the
Engineer.
30.20.6.2 Add for each addl. floor up to 5th floor sqm Tk. 31.28
30.20.6.3 Add for each addl floor for 6th floor to 9th floor sqm Tk. 39.10
30.20.6.4 Add for each addl floor for 10th floor and above sqm Tk. 46.92
30.21.1 Supplying, carrying, placing, providing (418 x 330 x 17) mm size of red colour sqm Tk. 68.00
concrete roof tiles on pre-fixed and pre-fabricated truss and fixing each tile to the
roof members of truss accepted by the Engineer.
30.21.2 Supplying, carrying, placing, providing (418 x 330 x 17) mm size of oriental colour sqm Tk. 63.00
concrete roof tiles on pre-fixed and pre-fabricated truss and fixing each tile to the
roof members of truss accepted by the Engineer.
30.21.3 Supplying, carrying, placing, providing (418 x 330 x 17) mm size of antique red sqm Tk. 68.00
colour concrete roof tiles on pre-fixed and pre-fabricated truss and fixing each tile
to the roof members of truss accepted by the Engineer.
30.21.4 Supplying, carrying, placing, providing (418 x 330 x 17) mm size of green colour sqm Tk. 73.00
concrete roof tiles on pre-fixed and pre-fabricated truss and fixing each tile to the
roof members of truss accepted by the Engineer.
30.22 Supplying, carrying, placing, providing of concrete Kerb stone size (600 x 300 x sqm Tk. 195.00
100) mm approved and accepted by the Engineer.
31.2 Field visit , fixing location of bore holes citing respective coordinates in X, Y & Per site Tk. 5,697.00
Z axes with respect to pre-determind datum(BM) and inspection of sampling and
samples by the Geo-tech. Expert / Engineer
31.3.1 Installation of boring equipment at site on dry ground/and a surface up to a Per point Tk. 839.00
maximum 750 mm under water and accepted by the Engineer.
31.3.2 Installation of boring equipment at site: for depth of water above 750 mm to 1500 Per point Tk. 4,223.00
mm and accepted by the Engineer.
31.3.3 Installation of boring equipment at site: For depth of water above 1500 mm Per point Tk. 5,715.00
(stagnant water) and accepted by the Engineer.
31.4 Boring 100 mm dia bore-hole by wash boring method:
31.4.1 Boring 100 mm dia bore-hole by wash boring method: 0 to 15 meter including the rm Tk. 214.00
depths for SPT operation and accepted by the Engineer.
31.4.2 Boring 100 mm dia bore-hole by wash boring method: 15 meter to 25 meter rm Tk. 235.00
including the depths for SPT operation and accepted by the Engineer.
31.4.3 Boring 100 mm dia bore-hole by wash boring method: 25meter to 35 meter including rm Tk. 241.00
the depths for SPT operation and as and accepted by the Engineer.
31.4.4 Boring 100 mm dia bore-hole by wash boring method: 35 meter to 45 meter rm Tk. 246.00
including the depths for SPT operation and accepted by the Engineer.
31.4.5 Boring 100 mm dia bore-hole by wash boring method: 45 meter & above including rm Tk. 256.00
the depths for SPT operation and accepted by the Engineer.
31.5 Execution of SPT with Standard Autometic Hammer (ASTM D-1586-84, hammer:
(140 + 2 Ibs) /(63.5 + 1 Kg), height of fall: (30" + 1") / (760 mm + 25 mm) including
withdrawn of drilling pipe from the bore-hole and fixing the steel cap with drilling pipe
and replacing the drilling pipe with cap into the bore hole up to the layer of interest
approved and accepted by the Engineer.
31.5.1 SPT @ 1500 mm interval: For 0 to 15 meter Per point Tk. 90.00
PWD SoR 2014 for Civil Works 202
31.8 Plate load test: mobilization, demobilization, arrangement of plates for loading and Per test Tk. 19,517.00
all other required materials, execution of tests, recording the data, preparation and
submission of test report (if desired by S.E. Design Circle) and accepted by the
Engineer.
31.9 Preparation, writing and submission of report on sub-soil investigation containing Per site Tk. 10,462.00
all parameters, bearing capacities, sections through all boreholes along different
axes, on two or more sets of data given or assumed, citing reference etc. and all
complete as per satisfaction and direction of engineer-in-charge.
Carrying out different test on soil samples collected from the sub-soil
investigation site accepted by the Engineer.
31.10 Specific gravity per set of Tk. 150.00
test
31.11 Grain size Analysis of soil by Sieve and Hydrometer analysis & Specific gravity test, per set of Tk. 1,050.00
And Providing ASTM Classification of Soil test
31.12 Visual Inspection & Classification of soil for engineering purposes per set of Tk. 113.00
test
31.13 Linear Shrinkage for cohesive soil per set of Tk. 600.00
test
31.14 Shrinkage limit for cohesive soil per set of Tk. 600.00
test
31.15 Atterberg limit test
31.15.1 Liquit limit for cohesive soil per set of Tk. 300.00
test
31.15.2 Plastic limit for cohesive soil per set of Tk. 300.00
test
31.16 Unit weight of soil per set of Tk. 226.00
test
31.17 Void ratio per set of Tk. 750.00
test
31.18 Natural moisture content per set of Tk. 150.00
test
31.19 Organic matter content per set of Tk. 1,126.00
test
31.20 Loss on ignition for cohesive soil per set of Tk. 863.00
test
31.21 Sand equivalent test per set of Tk. 1,200.00
test
PWD SoR 2014 for Civil Works 203
31.32 Sub - Soil investigation by exploratory borings and/ or by CPT, DCP etc. collecting
and necessary testing of samples in numbers as required for Stratification of Layers,
physical parameters of soils like Atterberg limits,Specific Gravity, Gain size
distribution(by wet seive, Hydrometer if required) ,shrinkage & swelling, Settlement ;
C -ф values and other Strength parameters to ascertain Bearing Capacity , Skin
friction, End bearings etc at layers of interest as per respective National/International
standards and entering all theese data & information in necessary Tables & Graphs ,
furnishing them in the form of Standard Sub-Soil Investigation Report duly signed by
competent Engineer & Exploratory Office.
31.33 Extra cost per site for Mobilization & demobilization in addition to any item
under 31.32
31.33.1 20 km within Dhaka, Chittagong,Rajshahi,Khulna, Sylhet , Barishal, Rangpur Per site Tk. 9,303.00
31.33.2 Other than divisional city : cost in addition to item 31.33.1 for the distance from per km Tk. 20.00
respective divisional HQ to site.
31.34 Extra cost per bore hole , if the same is under water by more than 1.5m in depth Tk. 4,223.00
a) The following table is provided as one of many quality controlling factors with the objective of estimating cost of material tests and to ensure quality leading to durable and safe structure. Sampling of
construction materials and products considered to be tested shall be done under the direct control and guidance of Procuring Entity. Representative(s) of the contractor shall be liable to collect or
prepare sample etc., send to the testing laboratories in an acceptable manner and collect authenticate copy / copies of test results / reports and duly submitted to the office of the Procuring Entity.
Procuring Entity shall recommend the contractor to prepare bill for payment. It is to be noted that materials and products to be tested and its frequencies described here are merely as minimum and
Procuring Entity may consider for more tests from Table A of this division
b) Tests are to be done in the nearest laboratory as far as possible.
c) Procuring Entity may include any other material or tests in their estimate with intimation to Convener, Schedule of Rates Committee, PWD.
d) Laboratory testing service provider:
1. HBRI : Housing and Building Research Institute. 120/3 Darus-Salam, Mirpur, Dhaka. Phone: +8802-8060989.
2. BUET (BRTC) : Bangladesh University of Engineering & Technology. Dhaka-1000. (Bureau of Research, Testing & Consultation) Phone: +8802-9665650-56, Ext: 7226.
3. KUET (CRTS) : Khulna University of Engineering & Technology. Khulna-9203. (Centre for Research Testing & Services). Phone: +88041-77480, Ext: 200.
4. RUET (DCE) : Rajshahi University of Engineering & Technology. (Department of Civil Engineering). Phone: +880721-750742-3.
5. SUST (CRTC) : Shahjalal University of Science & Technology. Sylhet-3114. (Centre for Research Testing & Consultancy). Phone: +880821-713491, Ext: 423.
6. CUET (BRTC) : Chittagong University of Engineering & Technology, Chittagong-4349. (Bureau of Research, Testing & Consultation). Phone: +880031-714948.
7. DUET (DCE) : Dhaka University of Engineering & Technology, Gazipur-1700. (Department of Civil Engineering). Phone: +88-02-9204703
32.0 Conducting laboratory test of engineering materials during construction in progressive manner well fitted with physical progress of work, by the procuring entity, with all logistic support
supposed to be given by the contractor; where sampling, sample sending to laboratory and collecting test results from the samples to laboratory shall be under strict control and guidance of
procuring entity following the norms elucidated in respective material standards like BDS, EN, ASTM, ISO, IS etc. and paid to the contractor after complete and proper documentation on:
1) laboratory test results in original
2) evidence of receiving samples in the laboratory in correct order
3) forwarding letter of procuring entity addressed to laboratory for testing
4) evidence of receiving “forwarding letter” with recipients’ full address and contact number
5) conformation on samples tested that sent in sealed condition bearing the signature and date of procuring entity
6) ensurance documents of sealing, signing and sending the samples.
PWD SoR 2014 for Civil Works 206
Structural Components & Testing Frequency UNIT RATES PER SET OF TEST in BDT
Compressive 28 days 28 days strength: 28 days strength: 100mm x - 2091.01 1568.25 3659.26 - 1960.3
strength: strength: 1 set of 3 1 set of 3 200mm and
32.1.1.2
non compliance
Concrete cylinders samples per samples per samples per floor of test results
150x 300 mm Building Unit. Building Unit. per Building Unit. etc. contractor
will be liable for
32.1.2
additional tests
Compressive 28 days 28 days strength: 28 days strength: - 3789.95 2352.38 16989.4 - 3659.3
and costs.
strength: strength: 1 set of 3 1 set of 3
32.1.2.2
32.2.4 Soundness Once per brand. Once per brand. Once per brand. in case of brand consult - - - - -
change, non lab
compliance of
test results etc.
contractor will be
liable for
additional tests
and costs.
32.2.5 Composition Once per brand. Once per brand. Once per brand. in case of brand consult - - - - -
Analysis change, non lab
compliance of
test results etc.
contractor will be
liable for
additional tests
and costs.
32.3 REBAR
32.3.1 TENSILE 1 set of 3 1 set of 3 1 set of 3 in case of brand - 2483.07 2613.76 2352.38 - -
STRENGTH samples. /2000 samples /12000 samples. /4800 change, non
TESTS: sft or less of sft or less of sft or less of compliance of
Yield Strength PLA. Minimum 1 PLA/floor, PLA/floor, test results etc.
Ultimate strength set. additional Minimum 1 set. Minimum 1 set. contractor will be
% Elongation etc. set for each additional set for additional set for liable for
change in brand. each change in each change in additional tests
brand. brand. and costs.
32.3.2 Bend 1 set of 3 1 set of 3 1 set of 3 in case of brand 3528.57 3005.81 3789.95 1176.19 3267.2 1176.2
samples /2000 samples /12000 samples. /4800 change, non
sft or less of sft or less of sft or less of compliance of
PLA. Minimum 1 PLA/floor, PLA/floor, test results etc.
set. additional Minimum 1 set. Minimum 1 set. contractor will be
set for each additional set for additional set for liable for
change in brand. each change in each change in additional tests
brand. brand. and costs.
32.3.3 Rebend Test 1 set of 3 1 set of 3 1 set of 3 in case of brand 4312.71 3789.95 4051.33 1437.57 6142.3 1437.6
samples /2000 samples /12000 samples. /4800 change, non
sft or less of sft or less of sft or less of compliance of
PLA. Minimum 1 PLA/floor, PLA/floor, test results etc.
set. additional Minimum 1 set. Minimum 1 set. contractor will be
set for each additional set for additional set for liable for
change in brand. each change in each change in additional tests
brand. brand. and costs.
PWD SoR 2014 for Civil Works 209
32.4.4 Aggregate crushing 1 set of 3 1 set of 3 1 set of 3 in case of non 1960.32 4182.01 3397.88 3920.63 2613.8 3920.6
value (ACV) samples /1500 samples/2500 sft samples /3000 compliance of
sft or less of or less of PLA. sft or less of test results etc.
PLA. Minimum 1 Minimum 1 set. PLA. Minimum 1 contractor will be
set. set. liable for
additional tests
and costs.
32.4.5 Salt content or 1 set of 3 1 set of 3 1 set 0f 3 in case of non - - 2091.01 2613.76 1568.3 2221.7
Sulphate content samples /1500 samples/2500 sft samples /3000 compliance of
sft or less of or less of PLA. sft or less of test results etc.
PLA. Minimum 1 Minimum 1 set. PLA. Minimum 1 contractor will be
set. set. liable for
additional tests
and costs.
32.4.6 C.B.R 1 set 3 times per 2 set 3 times per 3 set 3 times per in case of non - 37768.8 31887.8 39206.4 - 34632
3000 sft. 3000 sft. 3000 sft. compliance of
(applicable to (applicable to (applicable to test results etc.
road work). road work). road work). contractor will be
liable for
additional tests
and costs.
32.4.7 LOS 1 set 3 times per 1 set 3 times per 1 set 3 times per in case of non 1568.25 - 3789.95 4704.76 2613.8 4835.5
ANGELES 3000 sft. 3000 sft. 3000 sft. compliance of
ABRASION (applicable to (applicable to (applicable to test results etc.
TEST road work). road work). road work). contractor will be
liable for
additional tests
and costs.
32.5.1 Sieve Analysis 1 set of 3 1 set of 3 1 set of 3 in case of non 1045.5 2091.01 1568.25 1960.32 - 1960.3
samples /1500 samples/2500 sft samples /3000 compliance of
sft or less of or less of PLA. sft or less of test results etc.
PLA. Minimum 1 Minimum 1 set. PLA. Minimum 1 contractor will be
set. set. liable for
additional tests
and costs.
32.5.2 Unit Weight 1 set 3 samples 1 set 3 1 set 3 samples in case of non 653.44 2091.01 1829.63 2221.69 - 1960.3
/1500 sft or less samples/2500 sft /3000 sft or less compliance of
of PLA. Minimum or less of PLA. of PLA. Minimum test results etc.
1 set. Minimum 1 set. 1 set. contractor will be
liable for
additional tests
and costs.
32.5.3 Absorption and 1 set of 3 1 set of 3 1 set of 3 in case of non 1306.88 4051.32 3397.88 3920.63 - 3659.3
Specific Gravity samples /1500 samples/2500 sft samples /3000 compliance of
sft or less of or less of PLA. sft or less of test results etc.
PLA. Minimum 1 Minimum 1 set. PLA. Minimum 1 contractor will be
set. set. liable for
additional tests
and costs.
32.5.4 Bulking of Sand Once per Once per floor of Once per floor of in case of non - 5619.58 3920.63 4704.76 - 4574.1
Building Unit Building Unit. Building Unit. compliance of
test results etc.
contractor will be
liable for
additional tests
and costs.
32.5.5 Salt content or Once per Once per floor of Once per floor of in case of non - - 2091.01 2613.76 1568.3 2221.7
Sulphate content Building Unit Building Unit. Building Unit. compliance of
test results etc.
contractor will be
liable for
additional tests
and costs.
32.5.6 Mica content - - - Only demanded - 9801.59 4182.01 5227.51 - 4574.1
by design office
or, felt by PE on
visit site sample
/source.
PWD SoR 2014 for Civil Works 212
32.5.7 Organic Impurities - - - Only demanded 1960.32 2483.07 3267.2 3920.63 1568.3 2221.7
by design office
or, felt by PE on
visit site sample
/source.
32.5.8 Clay lump and - - - Only demanded 1306.88 3267.2 2744.44 3267.2 - 3005.8
friable particles by design office
or, felt by PE on
visit site sample
/source.
32.6 BRICKS
32.6.1 Crushing Strength Once when Once per floor of 1 set of 3 in case of brand 1568.25 3659.26 3528.57 3528.57 - 3397.9
Building Unit in Building Unit. samples/2500 sft change, non
brick work. or less of PLA. compliance of
Minimum 1 set. test results etc.
contractor will be
liable for
additional tests
and costs.
32.6.2 Water Absorption Once when Once per floor of 1 set of 3 in case of brand 784.13 1960.32 1698.94 1960.32 1306.9 1829.6
Building Unit in Building Unit. samples/2500 sft change, non
brick work. or less of PLA. compliance of
Minimum 1 set. test results etc.
contractor will be
liable for
additional tests
and costs.
32.6.3 Unit Weight Once when Once per floor of 1 set of 3 in case of brand - 3136.51 2613.76 3005.82 1960.3 2875.1
Building Unit in Building Unit. samples/2500 sft change, non
brick work. or less of PLA. compliance of
Minimum 1 set. test results etc.
contractor will be
liable for
additional tests
and costs.
PWD SoR 2014 for Civil Works 213
32.6.4 Size & Shape Once when Once per floor of 1 set of 3 in case of brand 784.13 3005.82 2483.07 3005.82 1960.3 2613.8
Building Unit in Building Unit. samples/2500 sft change, non
brick work. or less of PLA. compliance of
Minimum 1 set. test results etc.
contractor will be
liable for
additional tests
and costs.
32.6.5 Efflorscence Once when Once per floor of 1 set of 3 in case of brand 1306.88 3659.26 3136.51 3920.63 2352.4 3267.2
Building Unit in Building Unit. samples/2500 sft change, non
brick work. or less of PLA. compliance of
Minimum 1 set. test results etc.
contractor will be
liable for
additional tests
and costs.
32.7 HOLLOW BRICKS
32.7.1 Absoprtion - - 1 set of 3 in case of brand - 2091.01 1698.94 1960.32 - 1960.3
samples/3000 sft change, non
or less of PLA. compliance of
Minimum 1 set. test results etc.
contractor will be
liable for
additional tests
and costs.
PWD SoR 2014 for Civil Works 214
32.7.2 Unit Weight - - 1 set of 3 in case of brand - 2875.13 2352.38 2875.13 - 2613.8
samples/3000 sft change, non
or less of PLA. compliance of
Minimum 1 set. test results etc.
contractor will be
liable for
additional tests
and costs.
32.9 PAINT
PWD SoR 2014 for Civil Works 216
Note: Follow Division 32 B : LABORATORY CHARGE FOR TESTING OF MATERIALS or consult laboratory for the Rates of test items not found here.
Size HBRI BRTC, BUET CRTS, KUET DCE, RUET CRTC, SUST BRTC, CUET DCE, DUET
1 2 3 4 5 6 7 8 9 10
AGGREGATES
1 Absorption and Specific Gravity 1 Tk. 1,306.88 Tk. 4,051.32 Tk. 3,397.88 Tk. 3,920.63 Tk. - Tk. 3,659.26 -
2 Aggregate crushing value (ACV) 1 Tk. 1,960.32 Tk. 4,182.01 Tk. 3,397.88 Tk. 3,920.63 Tk. 2,613.76 Tk. 3,920.63 -
3 Aggregate impact value (AIV) 1 Tk. - Tk. 3,528.57 Tk. 3,136.51 Tk. 3,920.63 Tk. 2,613.76 Tk. 3,267.20 -
4 Angularity Number in/c sp. gr. 1 Tk. - Tk. 4,182.01 Tk. 3,397.88 Tk. 4,312.70 Tk. - Tk. 3,920.63 -
5 Bulking of Sand 1 Tk. - Tk. 5,619.58 Tk. 3,920.63 Tk. 4,704.76 Tk. - Tk. 4,574.07 -
6 CBR of base and sub-base material 1 Tk. - Tk. 37,768.78 Tk. 31,887.83 Tk. 39,206.35 Tk. - Tk. 34,632.28 -
7 Clay lump and friable particles 1 Tk. 1,306.88 Tk. 3,267.20 Tk. 2,744.44 Tk. 3,267.20 Tk. - Tk. 3,005.82 -
8 Coal and lignite 1 Tk. - Tk. 3,267.20 Tk. 2,613.76 Tk. 3,267.20 Tk. - Tk. 2,875.13 -
9 Elongation Index (EI) 1 Tk. 1,306.88 Tk. 3,528.57 Tk. 2,744.44 Tk. 3,267.20 Tk. - Tk. 3,267.20 -
10 Flakiness Index (FI) 1 Tk. 1,306.88 Tk. 4,182.01 Tk. 3,397.88 Tk. 4,312.70 Tk. - Tk. 3,920.63 -
11 L.A. Abrasion (ASTM C535 or ASTM C131) 1 Tk. 1,568.25 Tk. - Tk. 3,789.95 Tk. 4,704.76 Tk. 2,613.76 Tk. 4,835.45 -
12 Mica content 1 Tk. - Tk. 9,801.59 Tk. 4,182.01 Tk. 5,227.51 Tk. - Tk. 4,574.07 -
13 Organic Impurities 1 Tk. 1,960.32 Tk. 2,483.07 Tk. 3,267.20 Tk. 3,920.63 Tk. 1,568.25 Tk. 2,221.69 -
14 Effect of organic impurities 1 Tk. - Tk. 13,591.53 Tk. 11,369.84 Tk. 14,375.66 Tk. - Tk. 11,761.90 -
15 Standard Proctor test of aggregate (MDD) 1 Tk. - Tk. 14,767.72 Tk. 12,807.41 Tk. 15,682.54 Tk. - Tk. 13,722.22 -
16 Modified Proctor or Vibrating 1 Tk. - Tk. 22,608.99 Tk. 19,080.42 Tk. 23,523.81 Tk. - Tk. 20,910.05 -
17 Salt content or Sulphate content 1 Tk. - Tk. - Tk. 2,091.01 Tk. 2,613.76 Tk. 1,568.25 Tk. 2,221.69 -
18 Sieve analysis (CA) 1 Tk. 1,045.50 Tk. 3,528.57 Tk. 2,875.13 Tk. 3,528.57 Tk. 1,306.88 Tk. 3,136.51 -
19 Sieve analysis (Ballast) 1 Tk. - Tk. 4,182.01 Tk. 3,397.88 Tk. 4,312.70 Tk. - Tk. - -
20 Sieve analysis (FA) 1 Tk. 1,045.50 Tk. 2,091.01 Tk. 1,568.25 Tk. 1,960.32 Tk. - Tk. 1,960.32 -
21 Wash sieve analysis 1 Tk. - Tk. 2,875.13 Tk. 1,960.32 Tk. 2,352.38 Tk. - Tk. 2,613.76 -
PWD SoR 2014 for Civil Works 223
1 2 3 4 5 6 7 8 9 10
22 Soundness with Na2SO4 1 Tk. 7,841.27 Tk. 12,676.72 Tk. 10,455.03 Tk. 13,722.22 Tk. - Tk. 11,108.47 -
23 Soundness with Mg2SO4 1 Tk. 7,841.27 Tk. 16,074.60 Tk. 13,068.78 Tk. 15,682.54 Tk. - Tk. 13,068.78 -
24 Ten percent fines (10% fines) 1 Tk. 3,920.63 Tk. 7,057.14 Tk. 5,227.51 Tk. 6,273.02 Tk. 2,613.76 Tk. 6,534.39 -
25 Unit weight of aggregate (CA) 1 Tk. 653.44 Tk. 2,875.13 Tk. 2,091.01 Tk. 2,613.76 Tk. - Tk. 2,613.76 -
26 Unit weight of aggregate (FA) 1 Tk. 653.44 Tk. 2,091.01 Tk. 1,829.63 Tk. 2,221.69 Tk. - Tk. 1,960.32 -
27 Void ratio / Porosity 1 Tk. 653.44 Tk. 4,835.45 Tk. - Tk. 3,920.63 Tk. 1,568.25 Tk. 3,789.95 -
CEMENT CONCRETE
28 compressive strength : Tk. - Tk. 2,091.01 Tk. 1,568.25 Tk. 3,659.26 Tk. - Tk. 1,960.32 -
3
Concrete cylinders (100 x 200 mm)
29 Compressive strength: Tk. - Tk. 3,789.95 Tk. 2,352.38 Tk. 16,989.42 Tk. - Tk. 3,659.26 -
3
Concrete cylinders (150 x 300 mm)
30 Concrete Spun 3 Tk. - Tk. 3,267.20 Tk. 2,613.76 Tk. - Tk. - Tk. - -
31 Concrete cylinders casting & testing 3 Tk. 784.13 Tk. 19,080.42 Tk. 7,187.83 Tk. - Tk. - Tk. 16,989.42 -
32 Concrete beam in flexure 3 Tk. 3,920.63 Tk. 8,233.33 Tk. 6,534.39 Tk. 6,534.39 Tk. 3,920.63 Tk. 7,187.83 -
33 Concrete slab in flexure 3 Tk. - Tk. 11,369.84 Tk. 9,148.15 Tk. - Tk. - Tk. - -
34 Design of concrete (trial) mixes without Tk. - Tk. 60,769.84 Tk. 45,740.74 Tk. 58,809.52 Tk. - Tk. 54,888.89 -
1
admixture
35 Design of concrete (trial) mixes using Tk. - Tk. 67,826.98 Tk. 52,275.13 Tk. 58,809.52 Tk. - Tk. 54,888.89 -
1
admixture
36 Concrete Mixes design (single mix) 1 Tk. - Tk. - Tk. - Tk. - Tk. - Tk. - -
37 Concrete Mixes design using admixture Tk. - Tk. - Tk. - Tk. - Tk. - Tk. - -
1
(single mix)
38 Cubes (< 200 mm) 3 Tk. - Tk. 3,267.20 Tk. 2,352.38 Tk. 3,005.82 Tk. - Tk. 3,005.82 -
PWD SoR 2014 for Civil Works 224
1 2 3 4 5 6 7 8 9 10
39 Cubes (> 200 mm - 300 mm) 3 Tk. - Tk. 3,920.63 Tk. 2,613.76 Tk. - Tk. - Tk. 3,659.26 -
40 Cubes (> 300 x 300 mm), for per core cutting, Tk. - Tk. 7,057.14 Tk. 3,267.20 Tk. - Tk. - Tk. 6,534.39 -
1
each
41 a.In - situ Core cutting & testing without Tk. - Tk. 6,665.08 Tk. - Tk. - Tk. - Tk. - -
1
Scanning ,excluding field visit **
b. In-situ Core cutting & testing with Scanning, Tk. - Tk. 13,068.78 Tk. - Tk. - Tk. - Tk. - -
1
excluding field visit **
c.In- Lab Supplied Core Testing (3 Nos) Tk. - Tk. 2,744.44 Tk. - Tk. - Tk. - Tk. - -
42 a. In situ Per spot Impact hammer test ( 3- Tk. - Tk. - Tk. - Tk. - Tk. - -
1
test) excluding field visit *
b. In situ Winsor Pin test ( Per spot 3-test) Tk. - Tk. - Tk. - Tk. - Tk. - -
excluding field visit *
CEMENT
43 Compressive strength, 3 & 7 days 1 Tk. - Tk. - Tk. - Tk. 5,750.26 Tk. - Tk. - -
44 Compressive strength, 3, 7 and 28 days 1 Tk. 2,352.38 Tk. 9,409.52 Tk. 2,875.13 Tk. 8,625.40 Tk. 5,880.95 Tk. 8,625.40 -
45 Fineness 1 Tk. 1,306.88 Tk. 2,875.13 Tk. 1,698.94 Tk. 2,613.76 Tk. 1,045.50 Tk. 2,613.76 -
46 Setting time 1 Tk. 1,306.88 Tk. 3,528.57 Tk. 2,483.07 Tk. 3,267.20 Tk. - Tk. - -
47 Normal Consistency Tk. 653.44 Tk. 2,875.13 Tk. - Tk. 2,352.38 Tk. 1,045.50 Tk. 3,920.63 -
48 Density/ Sp.Gr Tk. 1,306.88 Tk. 4,182.01 Tk. - Tk. - Tk. - Tk. 3,920.63 -
BITUMEN
49 Bitumen content 1 Tk. 1,306.88 Tk. 13,852.91 Tk. 8,886.77 Tk. 11,761.90 Tk. - Tk. 11,108.47 -
50 Coating and striping test 1 Tk. - Tk. - Tk. 3,136.51 Tk. - Tk. - Tk. - -
51 Design of A.C. mixes (Marshall) 1 Tk. - Tk. 51,491.01 Tk. 39,206.35 Tk. 45,740.74 Tk. - Tk. 45,740.74 -
PWD SoR 2014 for Civil Works 225
1 2 3 4 5 6 7 8 9 10
52 Distillation 1 Tk. - Tk. 9,278.84 Tk. 7,187.83 Tk. 8,494.71 Tk. - Tk. 7,841.27 -
53 Ductility 1 Tk. - Tk. 3,005.82 Tk. 1,960.32 Tk. 2,613.76 Tk. 1,568.25 Tk. 2,483.07 -
54 Flash and fire-points 1 Tk. - Tk. 3,005.82 Tk. 2,091.01 Tk. 2,613.76 Tk. - Tk. 2,483.07 -
55 Float test 1 Tk. - Tk. 3,005.82 Tk. 2,091.01 Tk. 2,613.76 Tk. 1,568.25 Tk. 2,483.07 -
56 Loss on heating 1 Tk. - Tk. 3,005.82 Tk. 2,091.01 Tk. 2,613.76 Tk. 1,568.25 Tk. 2,483.07 -
57 Softening point (R&B) 1 Tk. - Tk. 3,005.82 Tk. 1,960.32 Tk. 2,613.76 Tk. 1,568.25 Tk. 2,483.07 -
58 Solubility 1 Tk. 1,306.88 Tk. 3,005.82 Tk. 2,091.01 Tk. 2,613.76 Tk. 1,568.25 Tk. 2,483.07 -
59 Specific gravity 1 Tk. 1,306.88 Tk. 3,005.82 Tk. 2,091.01 Tk. 2,613.76 Tk. 1,568.25 Tk. 2,483.07 -
60 Spot test 1 Tk. - Tk. 3,005.82 Tk. 2,091.01 Tk. 2,613.76 Tk. - Tk. - -
61 Standard penetration 1 Tk. 1,306.88 Tk. 3,005.82 Tk. 2,091.01 Tk. 2,613.76 Tk. 1,568.25 Tk. 2,483.07 -
62 Theoretical Max. Sp. Gr. A.C. mixes 1 Tk. - Tk. 4,312.70 Tk. 3,397.88 Tk. - Tk. - Tk. 3,920.63 -
63 Thin film oven 1 Tk. - Tk. 3,659.26 Tk. 2,483.07 Tk. 3,005.82 Tk. - Tk. - -
64 Viscosity (S.F.) 1 Tk. - Tk. 5,619.58 Tk. 4,443.39 Tk. 4,704.76 Tk. 2,613.76 Tk. 4,574.07 -
65 Viscosity (Kinemetic) 1 Tk. - Tk. 7,710.58 Tk. 6,011.64 Tk. 6,534.39 Tk. - Tk. 6,534.39 -
66 Water content 1 Tk. 1,306.88 Tk. 6,795.77 Tk. 5,227.51 Tk. 6,273.02 Tk. - Tk. 6,273.02 -
67 Any test on residue from loss-on-heating test 1 Tk. - Tk. 5,096.83 Tk. 3,920.63 Tk. 4,966.14 Tk. - Tk. 4,574.07 -
68 Any test on residue from thin film oven test 1 Tk. - Tk. 5,880.95 Tk. 4,443.39 Tk. 5,227.51 Tk. - Tk. - -
69 Ash content / Inorganic matter 1 Tk. 1,306.88 Tk. 5,619.58 Tk. 4,443.39 Tk. 5,227.51 Tk. - Tk. - -
70 In-stu Core Cutting & Test excluding Field Tk. - Tk. 15,290.48 Tk. - Tk. - Tk. - -
visit
BRICKS
PWD SoR 2014 for Civil Works 226
1 2 3 4 5 6 7 8 9 10
71 Absorption 5 Tk. 784.13 Tk. 1,960.32 Tk. 1,698.94 Tk. 1,960.32 Tk. 1,306.88 Tk. 1,829.63 -
72 Crushing strength 5 Tk. 1,568.25 Tk. 3,659.26 Tk. 3,528.57 Tk. 3,528.57 Tk. - Tk. 3,397.88 -
73 Efflorescence 10 Tk. 1,306.88 Tk. 3,659.26 Tk. 3,136.51 Tk. 3,920.63 Tk. 2,352.38 Tk. 3,267.20 -
74 Size and shape 5 Tk. 784.13 Tk. 3,005.82 Tk. 2,483.07 Tk. 3,005.82 Tk. 1,960.32 Tk. 2,613.76 -
75 Unit weight 5 Tk. - Tk. 3,136.51 Tk. 2,613.76 Tk. 3,005.82 Tk. 1,960.32 Tk. 2,875.13 -
76 Acid Resistance (Vitriol) 5 Tk. - Tk. - Tk. 7,318.52 Tk. 8,494.71 Tk. - Tk. - -
78 Compressive strength of Road Kerb Stone 3 Tk. - Tk. 4,312.70 Tk. 3,397.88 Tk. 3,920.63 Tk. - Tk. - -
79 Absorption 3 Tk. - Tk. 2,091.01 Tk. 1,698.94 Tk. 1,960.32 Tk. - Tk. 1,960.32 -
80 Unit Weight 3 Tk. - Tk. 2,875.13 Tk. 2,352.38 Tk. 2,875.13 Tk. - Tk. 2,613.76 -
81 Compressive strength of hollow bricks, Tk. - Tk. 5,880.95 Tk. - Tk. - Tk. - Tk. - -
3
Paver, Concrete blocks etc. in/c unit weight
GAUGES (Calibration)
82 Pressure gauge/ dial gauge 1 Tk. - Tk. 5,227.51 Tk. 4,443.39 Tk. 5,227.51 Tk. - Tk. 5,227.51 -
83 Hydraulic Jack with Pressure Gauge regular 1 Tk. - Tk. 24,438.62 Tk. 15,682.54 Tk. 27,444.44 Tk. - Tk. 20,910.05 -
84 Hydraulic Jack with Pressure Gauge large 1 Tk. - Tk. 32,410.58 Tk. - Tk. - Tk. - Tk. - -
85 Hydraulic Jack with Pressure Gauge, above Tk. - Tk. - Tk. - Tk. - Tk. - Tk. - -
1
600 ton
86 Deflection dial 1 Tk. - Tk. 3,659.26 Tk. 3,136.51 Tk. 3,267.20 Tk. - Tk. 3,267.20 -
87 Proving ring (< 100 Kn) 1 Tk. - Tk. 5,619.58 Tk. 3,789.95 Tk. 3,920.63 Tk. - Tk. 3,920.63 -
PWD SoR 2014 for Civil Works 227
1 2 3 4 5 6 7 8 9 10
88 Proving ring (100 Kn - 500 Kn) 1 Tk. - Tk. 6,403.70 Tk. 4,835.45 Tk. 5,227.51 Tk. - Tk. 5,227.51 -
89 Proving ring (> 500 kN) 1 Tk. - Tk. 7,710.58 Tk. 6,273.02 Tk. 7,187.83 Tk. - Tk. 6,534.39 -
90 Compression Testing machine excluding field Tk. - Tk. 12,676.72 Tk. 17,904.23 Tk. - Tk. 7,841.27 -
1
visit *
91 Dynamometer 1 Tk. - Tk. 10,455.03 Tk. 8,494.71 Tk. 11,761.90 Tk. - Tk. 10,455.03 -
92 Balance up to 20 kg 1 Tk. - Tk. - Tk. 7,187.83 Tk. 8,494.71 Tk. - Tk. 8,494.71 -
93 Blaine Apparatus Tk. - Tk. 9,540.21 Tk. - Tk. 8,494.71 Tk. - Tk. - -
96 Pipes (dia above 600 & up to 900 mm) 1 Tk. - Tk. 7,710.58 Tk. 5,880.95 Tk. 7,841.27 Tk. - Tk. - -
97 Pipes (dia above 900 & up to 1200 mm) 1 Tk. - Tk. 9,932.28 Tk. 7,187.83 Tk. 10,455.03 Tk. - Tk. - -
98 Pipes (dia above 1200 mm & up to 1524 mm) 1 Tk. - Tk. 12,676.72 Tk. 9,932.28 Tk. - Tk. - Tk. - -
99 In-situ pipe testing excluding field visit* 1 Tk. - Tk. 15,029.10 Tk. - Tk. - -
STEEL
100 Tension (deformed bar up to 25 mm) 3 Tk. - Tk. 2,483.07 Tk. 2,613.76 Tk. 2,352.38 Tk. - Tk. - -
101 Tension (plain bar up to 25 mm) 3 Tk. - Tk. - Tk. - Tk. 2,352.38 Tk. - Tk. - -
102 Tension (deformed bar > 25 mm) 3 Tk. - Tk. 3,659.26 Tk. 3,397.88 Tk. 3,267.20 Tk. - Tk. - -
103 Tension (plain bar > 25 mm) 3 Tk. - Tk. - Tk. 3,397.88 Tk. 3,136.51 Tk. - Tk. - -
104 Bend test (up to 25 mm) 3 Tk. - Tk. 1,176.19 Tk. 914.81 Tk. 1,306.88 Tk. - Tk. 1,045.50 -
105 Re-bend test (up to 25 mm) 3 Tk. - Tk. 1,437.57 Tk. 1,176.19 Tk. 1,306.88 Tk. - Tk. 2,352.38 -
PWD SoR 2014 for Civil Works 228
1 2 3 4 5 6 7 8 9 10
106 Bend test (above 25 mm) 3 Tk. - Tk. 1,306.88 Tk. 1,045.50 Tk. 1,568.25 Tk. - Tk. 1,176.19 -
107 Re-bend test (above 25 mm) 3 Tk. - Tk. 1,568.25 Tk. 1,306.88 Tk. 1,568.25 Tk. - Tk. 2,613.76 -
108 Shear test 3 Tk. - Tk. - Tk. 1,960.32 Tk. 3,267.20 Tk. - Tk. 3,528.57 -
109 Hardness (rock-well) 3 Tk. - Tk. 2,483.07 Tk. 2,091.01 Tk. 2,352.38 Tk. - Tk. 2,352.38 -
110 Impact 3 Tk. - Tk. 3,659.26 Tk. 3,136.51 Tk. 2,352.38 Tk. - Tk. 3,659.26 -
111 Stress-strain curves (modulus of elasticity) 3 Tk. 1,960.32 Tk. 8,494.71 Tk. 7,187.83 Tk. 9,148.15 Tk. 4,574.07 Tk. 7,841.27 -
112 Deformation measurement 3 Tk. - Tk. 3,267.20 Tk. 1,698.94 Tk. 2,352.38 Tk. - Tk. 1,960.32 -
113 Spring test 1 Tk. - Tk. 3,136.51 Tk. 2,613.76 Tk. 3,136.51 Tk. - Tk. 2,875.13 -
114 Tension (eye-hooks, anchor bolt) 1 Tk. - Tk. 5,096.83 Tk. 4,443.39 Tk. - Tk. - Tk. 4,704.76 -
115 Weight 3 Tk. 261.38 Tk. - Tk. - Tk. 980.16 Tk. 914.81 Tk. 914.81 -
116 H.T. Wire 3 Tk. - Tk. 7,841.27 Tk. 3,920.63 Tk. 4,704.76 Tk. - Tk. - -
117 Strand 3 Tk. - Tk. 14,114.29 Tk. 11,108.47 Tk. 11,108.47 Tk. - Tk. - -
TILES
119 Size and shape 5 Tk. - Tk. 2,091.01 Tk. 1,829.63 Tk. - Tk. - Tk. - -
120 Absorption 5 Tk. - Tk. 2,091.01 Tk. 1,829.63 Tk. - Tk. - Tk. - -
121 Flexural 5 Tk. - Tk. 2,875.13 Tk. 2,352.38 Tk. - Tk. - Tk. - -
SOIL
123 CBR of soils (three points) 1 Tk. - Tk. - Tk. 15,682.54 Tk. 20,910.05 Tk. 10,455.03 Tk. 20,910.05 -
PWD SoR 2014 for Civil Works 229
1 2 3 4 5 6 7 8 9 10
124 Field Tk. - Tk. - Tk. 25,484.13 Tk. 7,841.27 Tk. 6,534.39 Tk. 7,841.27 -
density(8spot+2proctor+2seives/Hydrometer 1
exluding field visit *
125 Sp. gr. 1 Tk. - Tk. 2,221.69 Tk. 1,960.32 Tk. 2,352.38 Tk. 1,568.25 Tk. 2,091.01 -
126 Hydrometer, sieve analysis & sp. gr 1 Tk. - Tk. 5,619.58 Tk. 4,835.45 Tk. 5,880.95 Tk. 3,920.63 Tk. - -
127 Linear shrinkage 1 Tk. - Tk. 2,091.01 Tk. 1,698.94 Tk. 1,960.32 Tk. 1,306.88 Tk. 1,960.32 -
128 Shrinkage limit 1 Tk. - Tk. 1,698.94 Tk. 1,437.57 Tk. 2,613.76 Tk. 1,306.88 Tk. 1,568.25 -
129 Liquid limit / Plastic Limit 1 Tk. - Tk. 3,528.57 Tk. 2,744.44 Tk. 3,267.20 Tk. 1,306.88 Tk. 3,267.20 -
130 Standard proctor 1 Tk. - Tk. 7,057.14 Tk. 5,619.58 Tk. 6,534.39 Tk. - Tk. 6,534.39 -
131 Modified proctor 1 Tk. - Tk. 8,494.71 Tk. 6,273.02 Tk. 7,841.27 Tk. 4,574.07 Tk. 7,841.27 -
132 Unit weight (wet & dry) 1 Tk. - Tk. 2,091.01 Tk. 1,829.63 Tk. 1,960.32 Tk. 1,568.25 Tk. 1,960.32 -
133 Void ratio (Sp. Gr. & Unit Wt.) 1 Tk. - Tk. 3,528.57 Tk. 3,136.51 Tk. 3,267.20 Tk. 2,613.76 Tk. 3,267.20 -
134 Moisture content 1 Tk. - Tk. 1,045.50 Tk. 784.13 Tk. 980.16 Tk. 784.13 Tk. 914.81 -
135 Organic matter content 1 Tk. - Tk. 3,659.26 Tk. 3,136.51 Tk. 3,920.63 Tk. 2,613.76 Tk. 3,397.88 -
136 Loss on ignition 1 Tk. - Tk. 3,136.51 Tk. 2,613.76 Tk. 3,005.82 Tk. - Tk. 2,875.13 -
137 Grain Size Analysis 1 Tk. - Tk. - Tk. - Tk. 1,960.32 Tk. - Tk. - -
138 Grain Size Analysis by wash seiving 1 Tk. - Tk. 2,875.13 Tk. 2,091.01 Tk. 2,352.38 Tk. 1,568.25 Tk. - -
139 Sand equivalent test 1 Tk. - Tk. 4,704.76 Tk. 3,920.63 Tk. 4,966.14 Tk. - Tk. 4,312.70 -
140 Permeability (cohesive) 1 Tk. - Tk. 14,767.72 Tk. 5,227.51 Tk. 6,534.39 Tk. - Tk. 13,722.22 -
141 Permeability - falling head for non-cohesive Tk. - Tk. 7,057.14 Tk. 3,136.51 Tk. 3,267.20 Tk. - Tk. 5,880.95 -
1
sample
142 One diamensional Consolidation (full) 1 Tk. - Tk. - Tk. - Tk. - Tk. - Tk. - -
PWD SoR 2014 for Civil Works 230
1 2 3 4 5 6 7 8 9 10
143 One diamensional Consolidation (e - los p) 1 Tk. - Tk. 14,767.72 Tk. 13,068.78 Tk. 14,375.66 Tk. - Tk. 13,722.22 -
144 Consolidated drain test (direct shear test) 3 Tk. - Tk. 8,494.71 Tk. - Tk. 7,841.27 Tk. - Tk. 7,318.52 -
145 Consolidated drained tri-axial test 3 Tk. - Tk. 8,494.71 Tk. - Tk. 32,671.96 Tk. - Tk. - -
146 Consolidated quick test (direct shear test) 3 Tk. - Tk. 7,057.14 Tk. - Tk. 6,534.39 Tk. - Tk. - -
147 Consolidated un-drained tri-axial test with Tk. - Tk. 28,228.57 Tk. - Tk. 26,137.57 Tk. - Tk. - -
3
pore pressure
148 Consolidated un-drained tri-axial test without Tk. - Tk. 28,228.57 Tk. - Tk. 26,137.57 Tk. - Tk. 26,137.57 -
3
pore pressure
149 Unconfined compression 1 Tk. - Tk. 4,182.01 Tk. 3,397.88 Tk. 3,920.63 Tk. 3,136.51 Tk. 3,920.63 -
150 Unconsolidated quick test (direct shear test) 3 Tk. - Tk. 5,619.58 Tk. 3,920.63 Tk. 5,227.51 Tk. - Tk. 5,227.51 -
151 Unconsolidated un-drained tri-axial test Tk. - Tk. 14,114.29 Tk. 10,455.03 Tk. 11,761.90 Tk. - Tk. 11,761.90 -
3
(without pore pressure)
152 Max. and Min density of cohesionless soil 3 Tk. - Tk. 6,403.70 Tk. 5,619.58 Tk. 6,534.39 Tk. - Tk. - -
GEOTEXTILES
153 Apparent/ effective opening size (AOS/EOS) Tk. - Tk. 4,704.76 Tk. 3,920.63 Tk. 4,574.07 Tk. - Tk. 4,312.70 -
3
or pore size
154 Burst test index 3 Tk. - Tk. 3,528.57 Tk. 2,875.13 Tk. 4,574.07 Tk. - Tk. 3,267.20 -
155 Index puncture resistance or CBR puncture 3 Tk. - Tk. 3,528.57 Tk. 2,875.13 Tk. 3,267.20 Tk. - Tk. - -
156 Cone penetration test 3 Tk. - Tk. 3,528.57 Tk. 2,875.13 Tk. 3,267.20 Tk. - Tk. - -
157 Grab tensile test 3 Tk. - Tk. 4,704.76 Tk. 3,920.63 Tk. 4,574.07 Tk. - Tk. 4,312.70 -
158 Hor. water permeability under 2 kN/m2 Tk. - Tk. 9,932.28 Tk. 5,227.51 Tk. 6,534.39 Tk. - Tk. - -
3
pressure
PWD SoR 2014 for Civil Works 231
1 2 3 4 5 6 7 8 9 10
159 Seam strength 3 Tk. - Tk. 4,704.76 Tk. 3,920.63 Tk. 4,574.07 Tk. - Tk. - -
160 Thickness 3 Tk. - Tk. 1,437.57 Tk. 1,045.50 Tk. 1,306.88 Tk. - Tk. 1,306.88 -
161 Trapezoidal tearing strength 3 Tk. - Tk. 4,704.76 Tk. 3,920.63 Tk. 4,966.14 Tk. - Tk. 4,312.70 -
162 Unit weight/mass 3 Tk. - Tk. 2,221.69 Tk. 1,960.32 Tk. 2,352.38 Tk. - Tk. 2,091.01 -
163 Ver. permeability under 2 kN2/m and 200 Tk. - Tk. 9,148.15 Tk. 7,841.27 Tk. 9,148.15 Tk. - Tk. - -
3
kN2/m
164 Ver. permeability under 2 kN2/m Pressure 3 Tk. - Tk. 5,619.58 Tk. 4,835.45 Tk. 5,880.95 Tk. - Tk. - -
165 Water permeability by permitivity 3 Tk. - Tk. 4,704.76 Tk. 3,920.63 Tk. 4,574.07 Tk. - Tk. - -
166 Horizontal water permeability test. 3 Tk. - Tk. 10,324.34 Tk. 5,227.51 Tk. 6,534.39 Tk. - Tk. - -
167 Strip/wide-width tensile test (tensile Tk. - Tk. 5,619.58 Tk. 3,920.63 Tk. 3,267.20 Tk. - Tk. - -
3
elongation)
MISCELLLANEOUS
Rubber/Plastic/PVC materials
168 Tension 5 Tk. - Tk. 3,397.88 Tk. 2,875.13 Tk. 3,267.20 Tk. - Tk. 3,136.51 -
169 Hardness 1 Tk. - Tk. 2,091.01 Tk. 1,698.94 Tk. 1,960.32 Tk. - Tk. - -
170 Flexure 5 Tk. - Tk. 4,051.32 Tk. 3,397.88 Tk. 3,920.63 Tk. - Tk. 3,789.95 -
171 Compression set 1 Tk. - Tk. 4,051.32 Tk. 3,397.88 Tk. 4,574.07 Tk. - Tk. 3,789.95 -
172 Compression stiffness 1 Tk. - Tk. 5,619.58 Tk. 4,835.45 Tk. 5,227.51 Tk. - Tk. 5,227.51 -
OTHERS
PWD SoR 2014 for Civil Works 232
1 2 3 4 5 6 7 8 9 10
173 Tension tests on Bolt, hooks 3 Tk. - Tk. - Tk. - Tk. - Tk. - Tk. - -
174 Compression of fibre glass(one sample) 1 Tk. - Tk. - Tk. 1,698.94 Tk. - Tk. - Tk. - -
176 Design of deep tube-well (depth up to 600') Tk. - Tk. 14,114.29 Tk. - Tk. - Tk. - Tk. - -
1
inc 8nos sand test
177 Design of deep tube-well (depth above Tk. - Tk. 33,456.08 Tk. - Tk. - Tk. - Tk. - -
1
600')inc. 11nos sand test
178 Flexure test of timber 1 Tk. - Tk. 8,494.71 Tk. 7,318.52 Tk. - Tk. - Tk. - -
179 Load test on man-hole cover (< 18 inch dia) 1 Tk. - Tk. 7,057.14 Tk. 4,704.76 Tk. - Tk. - Tk. - -
180 Load test on man-hole cover (>18 inch dia) 1 Tk. - Tk. 7,710.58 Tk. 5,096.83 Tk. - Tk. - Tk. - -
181 Tension test of fiber glass strainer/pipes 1 Tk. - Tk. - Tk. 3,920.63 Tk. - Tk. - Tk. - -
Elastomeric Bearings
182 Vulcanized rubber and thermoplastic 3 Tk. - Tk. 5,880.95 Tk. 5,750.26 Tk. - Tk. - Tk. 5,880.95 -
elastomer in tension & elongation at break
ASTM D412
183 Short duration compression test on plain and 1 Tk. - Tk. 5,750.26 Tk. 5,619.58 Tk. - Tk. - Tk. 5,880.95 -
steel laminated elastomeric bearings for
bridges, ASTM D 4014
184 Long duration compression test on plain and 1 Tk. - Tk. 11,631.22 Tk. 11,239.15 Tk. - Tk. - Tk. 11,761.90 -
steel laminated elastmeric bearings for
bridges, ASTM D4014
185 Determination of shear modulus, ASTM 3 Tk. - Tk. 8,102.65 Tk. - Tk. - Tk. 9,148.15 -
D4014
PWD SoR 2014 for Civil Works 233
1 2 3 4 5 6 7 8 9 10
186 Test for compression set, ASTM D395 4 Tk. - Tk. 7,318.52 Tk. - Tk. - Tk. 6,011.64 -
187 Determination of durometer hardness, ASTM 1 Tk. - Tk. 2,483.07 Tk. 2,483.07 Tk. - Tk. - Tk. - -
D2240
188 Test for rubber durability-deterioration in an 3 Tk. - Tk. 4,966.14 Tk. 4,835.45 Tk. - Tk. - Tk. 4,835.45 -
air oven, ASTM D573
189 Test for determining the adhesion on rigid 1 Tk. - Tk. 4,051.32 Tk. 3,920.63 Tk. - Tk. - Tk. - -
substrates, ASTM D429
190 Dimensional test (external and internal) giving 1 Tk. - Tk. 2,483.07 Tk. - Tk. - Tk. - Tk. 2,483.07 -
number & thickness of steel plates, elastomer
parallelism, elastomer thickness, ASTM
D4014
191 Ash content 1 Tk. - Tk. 4,051.32 Tk. 3,920.63 Tk. - Tk. - Tk. 3,920.63 -
WATER
Drinking Water
192 Water (Drink + As), Total Package Fee 1 Tk. - Tk. - Tk. 8,625.40 Tk. - Tk. - Tk. 7,971.96 -
193 Water (Drink + As + TC & FC), Total Package Tk. - Tk. - Tk. 10,455.03 Tk. 9,148.15 Tk. - Tk. - -
1
Fee
194 pH/Hydrogen Ion density 1 Tk. 653.44 Tk. - Tk. 392.06 Tk. 392.06 Tk. - Tk. 392.06 -
195 Color (filtered) 1 Tk. - Tk. - Tk. 261.38 Tk. 392.06 Tk. - Tk. 392.06 -
196 Carbon dioxide (CO2) / Acidity 1 Tk. - Tk. 261.38 Tk. 261.38 Tk. 392.06 Tk. - Tk. 261.38 -
197 Chlorine (Cl) 1 Tk. - Tk. - Tk. 653.44 Tk. 914.81 Tk. - Tk. 914.81 -
198 Fluoride (Fl) 1 Tk. - Tk. 653.44 Tk. 653.44 Tk. 980.16 Tk. - Tk. 653.44 -
199 Iron (Fe) 1 Tk. - Tk. - Tk. 784.13 Tk. 1,568.25 Tk. - Tk. 1,568.25 -
PWD SoR 2014 for Civil Works 234
1 2 3 4 5 6 7 8 9 10
200 Manganese (Mn) 1 Tk. - Tk. 1,960.32 Tk. 1,568.25 Tk. 1,829.63 Tk. - Tk. 1,829.63 -
201 Nitrate-Nitrogen (NO3-N) 1 Tk. - Tk. 784.13 Tk. 653.44 Tk. 784.13 Tk. - Tk. 784.13 -
202 Alkalinity / Bicarbonate 1 Tk. 653.44 Tk. 653.44 Tk. 392.06 Tk. 653.44 Tk. - Tk. 653.44 -
203 Total hardness 1 Tk. 653.44 Tk. 1,045.50 Tk. 718.78 Tk. 914.81 Tk. - Tk. 914.81 -
204 Total dissolved solids (TDS) 1 Tk. 653.44 Tk. 1,176.19 Tk. 914.81 Tk. - Tk. - Tk. 1,045.50 -
205 Arsenic (As) 1 Tk. - Tk. 1,960.32 Tk. 1,568.25 Tk. 1,960.32 Tk. - Tk. 1,829.63 -
206 Turbidity 1 Tk. - Tk. 392.06 Tk. 326.72 Tk. 392.06 Tk. 261.38 Tk. 392.06 -
207 Faecal Coliform (FC) 1 Tk. - Tk. 1,437.57 Tk. 1,045.50 Tk. - Tk. - Tk. - -
208 Total coliform (TC) 1 Tk. - Tk. 1,437.57 Tk. 1,045.50 Tk. 1,306.88 Tk. - Tk. - -
209 Manganese density (Mg) 1 Tk. - Tk. 3,528.57 Tk. 2,091.01 Tk. - Tk. - Tk. - -
210 Sodium (Na) density (SAR) 1 Tk. - Tk. 4,966.14 Tk. - Tk. - Tk. - Tk. - -
Pollution Study
211 Bio-chemical Oxygen demand (BOD)-drinking Tk. - Tk. - Tk. 1,829.63 Tk. 2,352.38 Tk. 653.44 Tk. 2,091.01 -
1
water
212 Bio-chemical Oxygen demand (BOD)-waste Tk. - Tk. - Tk. 2,875.13 Tk. - Tk. - Tk. - -
1
water
213 Chemical Oxygen demand (COD)-Dichromate 1 Tk. - Tk. - Tk. 2,091.01 Tk. 2,352.38 Tk. 653.44 Tk. 2,221.69 -
214 Dissolved Oxygen (DO) 1 Tk. - Tk. - Tk. - Tk. - Tk. 653.44 -
215 Sulphate 1 Tk. - Tk. - Tk. 718.78 Tk. 784.13 Tk. 392.06 Tk. 784.13 -
216 Color (Scanning) 1 Tk. - Tk. - Tk. 784.13 Tk. 784.13 Tk. - Tk. - -
Miscellaneous Parameters
PWD SoR 2014 for Civil Works 235
1 2 3 4 5 6 7 8 9 10
217 Selenium (Se) 1 Tk. - Tk. 3,920.63 Tk. - Tk. - Tk. - Tk. - -
218 Carbonate (CO3) 1 Tk. - Tk. 653.44 Tk. 326.72 Tk. 1,176.19 Tk. 261.38 Tk. 1,176.19 -
219 Ammonia-Nitrogen (NH3-N) 1 Tk. - Tk. 1,306.88 Tk. 1,045.50 Tk. 1,045.50 Tk. - Tk. 784.13 -
220 Nitrate -Nitrogen (NO2-N) 1 Tk. - Tk. 784.13 Tk. 653.44 Tk. 1,045.50 Tk. - Tk. 4,574.07 -
221 Aluminium (Al) 1 Tk. - Tk. 4,966.14 Tk. 4,574.07 Tk. 4,966.14 Tk. - Tk. 1,829.63 -
222 Arsenic (As) 1 Tk. - Tk. 1,960.32 Tk. - Tk. 1,960.32 Tk. 1,568.25 Tk. 1,829.63 -
223 Bromine content (Br) 1 Tk. - Tk. 653.44 Tk. 653.44 Tk. 784.13 Tk. - Tk. 653.44 -
224 Total Chlorine content, Cl2 1 Tk. - Tk. 784.13 Tk. 653.44 Tk. 784.13 Tk. - Tk. 653.44 -
225 Free Chlorine content, Cl2 1 Tk. - Tk. 784.13 Tk. 653.44 Tk. 784.13 Tk. - Tk. 653.44 -
226 Break-point Chlorination 1 Tk. - Tk. 9,932.28 Tk. 7,449.21 Tk. 9,148.15 Tk. 3,267.20 Tk. 9,148.15 -
227 Hydrogen Sulphide (H2S) 1 Tk. - Tk. 1,045.50 Tk. 784.13 Tk. 784.13 Tk. 653.44 Tk. 784.13 -
228 Iodine content (I) 1 Tk. - Tk. 653.44 Tk. 653.44 Tk. 784.13 Tk. - Tk. 653.44 -
229 Mercury (Mg) 1 Tk. - Tk. 5,619.58 Tk. 4,051.32 Tk. 5,880.95 Tk. - Tk. 5,227.51 -
230 Phosphate content (PO4) 1 Tk. - Tk. 4,182.01 Tk. 914.81 Tk. 980.16 Tk. 522.75 Tk. 914.81 -
231 Sulphite (SO3) 1 Tk. - Tk. 784.13 Tk. 849.47 Tk. 980.16 Tk. - Tk. 784.13 -
232 Silica-content (SiO2) 1 Tk. - Tk. 1,306.88 Tk. 914.81 Tk. 980.16 Tk. - Tk. 1,176.19 -
233 Ba/Ca/Cr/Cu/Cd/K/Na/Ni/Pb/Zn 1 Tk. - Tk. - Tk. 1,960.32 Tk. 1,829.63 Tk. - Tk. 1,829.63 -
234 Oil and Grease content in Water 1 Tk. - Tk. - Tk. 3,659.26 Tk. 3,267.20 Tk. - Tk. 1,568.25 -
235 Oil and Grease content in Waste Water 1 Tk. - Tk. - Tk. - Tk. - Tk. - Tk. - -
PWD SoR 2014 for Civil Works 236
1 2 3 4 5 6 7 8 9 10
236 Organic Matter 1 Tk. - Tk. 2,744.44 Tk. 2,352.38 Tk. 2,613.76 Tk. - Tk. 2,613.76 -
237 Boron (B) 1 Tk. - Tk. 3,528.57 Tk. 1,960.32 Tk. 1,829.63 Tk. - Tk. 1,829.63 -
238 Electrical conductivity (EC) 1 Tk. - Tk. 653.44 Tk. 653.44 Tk. 653.44 Tk. 130.69 Tk. - -
239 Total Solids (TS) 1 Tk. - Tk. 2,352.38 Tk. 914.81 Tk. 980.16 Tk. 653.44 Tk. 1,045.50 -
240 (TSS) or (TSS + TDS) 1 Tk. - Tk. 2,352.38 Tk. 1,829.63 Tk. 1,960.32 Tk. - Tk. 2,091.01 -
241 Pb or Cd release of Tableware 1 Tk. - Tk. 2,352.38 Tk. 1,829.63 Tk. 1,960.32 Tk. - Tk. 2,091.01 -
242 Extraction charge for oil 1 Tk. - Tk. - Tk. 1,829.63 Tk. - Tk. - Tk. 2,613.76 -
243 Extraction charge for salt 1 Tk. - Tk. - Tk. 1,045.50 Tk. - Tk. - Tk. 2,613.76 -
244 Extraction of TCLP(Toxic Characteristic Tk. - Tk. - Tk. - Tk. - Tk. - Tk. - -
1
Leaching Procedure) excluding metal test
246 Boron (B) 1 Tk. - Tk. - Tk. 3,267.20 Tk. 3,528.57 Tk. - Tk. 3,267.20 -
247 Electrical conductivity (EC) 1 Tk. - Tk. 1,045.50 Tk. 653.44 Tk. 980.16 Tk. 130.69 Tk. 1,045.50 -
248 Organic matter for solid, sludge 1 Tk. - Tk. 2,875.13 Tk. 1,568.25 Tk. 1,960.32 Tk. - Tk. 1,960.32 -
249 Organic matter(Wet Combustion Method) 1 Tk. - Tk. 3,397.88 Tk. 2,875.13 Tk. 3,920.63 Tk. - Tk. 3,267.20 -
250 Ammonia-Nitrogen (NH3-N) 1 Tk. - Tk. 1,306.88 Tk. 1,045.50 Tk. 1,437.57 Tk. - Tk. 1,306.88 -
251 Phosphate content (PO4) 1 Tk. - Tk. - Tk. 914.81 Tk. 1,437.57 Tk. - Tk. 2,613.76 -
252 Exchangeable Sodium (Na) 1 Tk. - Tk. - Tk. 3,267.20 Tk. 3,920.63 Tk. - Tk. 3,267.20 -
253 Aluminium (Al) 1 Tk. - Tk. 4,966.14 Tk. 4,574.07 Tk. 5,227.51 Tk. - Tk. 4,704.76 -
PWD SoR 2014 for Civil Works 237
1 2 3 4 5 6 7 8 9 10
254 Arsenic (As) 1 Tk. - Tk. 1,960.32 Tk. 1,568.25 Tk. 2,613.76 Tk. - Tk. 2,091.01 -
255 Mercury (Hg) 1 Tk. - Tk. 5,619.58 Tk. 4,574.07 Tk. 5,227.51 Tk. - Tk. 4,574.07 -
256 Sulphite (SO3) 1 Tk. - Tk. 784.13 Tk. 1,829.63 Tk. 2,613.76 Tk. - Tk. 3,267.20 -
257 Ca, Cd, Cl, K, Mg, Na, Pb 1 Tk. - Tk. 1,960.32 Tk. 2,417.72 Tk. 2,352.38 Tk. - Tk. - -
258 Toxic Characterstics Leaching Procedure Tk. - Tk. 7,057.14 Tk. 7,187.83 Tk. 8,886.77 Tk. - Tk. - -
1
(TCLP)
259 TOC 1 Tk. - Tk. - Tk. 8,102.65 Tk. 7,187.83 Tk. - Tk. 2,352.38 -
260 Other Metals 1 Tk. - Tk. - Tk. 1,829.63 Tk. 2,352.38 Tk. - Tk. - -
261 Oil and Grease 1 Tk. - Tk. - Tk. - Tk. - Tk. - Tk. - -
Sampling
262 Sampling for Bacteriological Analysis Tk. - Tk. - Tk. 18,949.74 Tk. - -
1
excluding field visit *
263 Sampling for physical and chemical Analysis Tk. - Tk. - Tk. 18,949.74 Tk. - -
1
excluding field visit *
265 Swimming Pool: pH, Alkalinity, Color, Tk. - Tk. - Tk. 6,273.02 Tk. 8,886.77 Tk. - Tk. 8,494.71 -
Turbidity, Total Suspended Solids, Chloride, 1
TC, FC, Fe, NO3, PO4
266 Textile (Only Dyeing) pH, Alkalinity, Turbidity, Tk. - Tk. - Tk. 6,795.77 Tk. 8,886.77 Tk. - Tk. 8,494.71 -
Hardness, Chemical Oxygen Demand
1
(KMnO), Total Chlorine, NO3, NO2, Fe, Mn,
Cu, TS.
PWD SoR 2014 for Civil Works 238
1 2 3 4 5 6 7 8 9 10
267 Textile (Boiler) pH, Alkalinity, Turbidity, Tk. - Tk. - Tk. 6,534.39 Tk. 8,886.77 Tk. - Tk. 8,494.71 -
Hardness, Chemical Oxygen Demand
1
(KMnO), Total Chlorine, Ca, Fe, Mn, SiO2,
SO4
268 Tanning: pH, Alkalinity, Color, Turbidity, Tk. - Tk. - Tk. 3,005.82 Tk. 3,528.57 Tk. - Tk. - -
1
Hardness, Fe, Mn
269 Cooling: pH, Hardness, Turbidity, Total Tk. - Tk. - Tk. 4,443.39 Tk. 5,880.95 Tk. - Tk. 5,227.51 -
Dissolved Solids, Fe, Mn, COD, (KMnO4), 1
PO4
270 Paper and Pulp (Ground wood): pH, Alkalinity, Tk. - Tk. - Tk. 4,574.07 Tk. 6,273.02 Tk. - Tk. 5,227.51 -
Color, Turbidity, Hardness, Total Dissolved 1
Solids, Fe, Mn, SiO2, CO2
271 Boiler Feed Water (including oil & grease): Tk. - Tk. - Tk. 5,750.26 Tk. 7,841.27 Tk. - Tk. 6,534.39 -
pH, Alkalinity, Color, P-Alkalinity, M-Alkalinity,
1
Turbidity, Hardness, Total Dissolved Solids,
Total Suspended Solids.
Air Pollution
273 (CO, SO, NO, CH4) excluding visit visit 3 - - - - - - -
1 2 3 4 5 6 7 8 9 10
Soil Boring
278 Soil boring + Relevent test (per bore inside - - - - - - -
1
Dhaka) depth up to 60'-0"
Site Visit
282 Site Visit inside Dhaka 1 - - - - - - -
uPVC Pipe
1/2" - 4"
1 2 3 4 5 6 7 8 9 10
5" - 6"
1 2 3 4 5 6 7 8 9 10
Filter Test - - - - - - -
315 12"
14"
1 2 3 4 5 6 7 8 9 10
16"
NOTE-2 : Consult laboratory for the rates of test items not found here.
PWD SoR 2014 for Civil Works 245
ANNEXURE
PWD SoR 2014 for Civil Works 246
Annexure-A
1. PLAR are the rates to assess the cost of buildings when detail Architectural and Structural Design is
not available.
2. PLAR are formulated by studying huge vari9ables, data and assumptions only provide hints on the cost
of construction over a couple of years.
3. A wide range variation of actual cost from PLAR directs to study (i) architectural & structural design (ii)
site condition (iii) decision built up.
4. Exclusive works relates to high density of cost like glazed curtain wall, aluminium composite curtain
wall/cladding are beyond the scope of PLAR.
5. PLAR never resembles an actual cost; instead it’s a probabilistic cost for fund conformity after time
dependent tender and agreement procedure to run a smooth project.
6. PLAR costs for buildings are to be assessed after confirming the building category namely ‘standard’,
‘super’ and ‘superior’.
7. ‘Special’ category buildings are residents/offices hold by constitutional posts or other building to be
decided by Chief Engineer, PWD and Chief Architect, Department of Architecture. The finishing
schedule and corresponding rates for these category buildings are to be fixed as per actual estimate.
8. PLAR includes 19% extra cost for VAT and Other charges.
Plinth Area is the area bounded by exterior perimeter of a floor or the perimeter formed by joining the
lines on the outer faces of columns in the floor, including any area kept opening what so ever, except
courtyard open to sky.
The category of buildings should be understood by the terms standard, super, superior on their usual
meanings, but as a guide Standard category of buildings is that, made in quality and provided with
general basic facilities and finished components are mostly of local materials, bricks, sand, cement and
lime based but a hygienic finish in toilets, lavatory & kitchen.
PWD SoR 2014 for Civil Works 251
5. Roof-top RCC water tank in/c beams & supports etc. : Tk. 142 per gal.
7. Internal Electrification :
8. Gas Connection :
(i) Ground Floor Tk. 342.20 Per sqm
(ii) Other Floors Tk. 136.88 Per sqm
(i)
Boundary wall 125 mm thick with 250 x 250 mm brick pillar, 1.52m in
height :
Construction of 125 mm thick boundary wall with 250 mm x 250 mm size Tk. 4,329.62 per rm
brick pillar @ 2.44 meter c/c , of height 1.52 meter above G.L and 0.76 m
below G.L and RCC (f'c = 19 MPa, minimum f'cr = 24 MPa in nominal mix 1
: 2 : 4) coping of 90 mm thick and 375 mm width, 12 mm thick plaster (1:6)
in both sides of the wall including the cost of reinforcement and white
washing etc.
Construction of R.C.C.(f'c = 19 MPa, minimum f'cr = 24 MPa in nominal mix Tk. 6,890.71 per rm
1 : 2 : 4) boundary wall of height 1.52 meter above G.L and one meter
below G.L with column 250 mm x 250 mm size and tie beam 250 mm x 250
mm at ground level, 75 mm thick and 375 mm width R.C.C coping and 125
mm (1:4) brick work in between the columns, 12 mm thick cement plaster
(1:6) on the both sides of brick surface and 6 mm thick cement plaster (1:4)
on R.C.C., in all exposed surface on both sides of the boundary wall
including the cost of M.S rod white washing etc.
Annexure-B
ROUGH ESTIMATE:
HEAD OF ACCOUNTS
Revenue
Development
COMPONENTS OF ESTIMATE
1. Project Profile.
2. Report.
3. Abstract of Cost.
4. Estimate.
5. Site plan.
6. Building Plan.
PWD SoR 2014 for Civil Works 255
CHARGES:
1. Project in Revenue Head: Charges Nil.
2. Project in Development Head:
(a) Works undertaken by PWD for Ministry of Housing and Public Works:7.00%
(b) Works undertaken for other Ministries:8.00%
3. Deposit works:10.00%
DETAIL ESTIMATE
1. Report.
2. Detail Building Plan, Elevation, Section & Structural Drawings.
3. Detail measurement of each individual item along with their information in drawings, sites etc.
4. An abstract of cost.
5. Proposed works specially boundary wall, gate, road, external water supply, sewerage line shown in red.
4. INTERNALELECTRIFICATION : Tk. D
7. Earthling system
8. Overhead transmission line
9. Underground cable laying
10. Compound light
17. QUALITY ASSURANCE, MATERIAL SAMPLE COLLECTION & TESTING, ETC (1.00% on Tk. Q) : Tk. R
18. CONTINGENCY (Probable unforeseen expenditure related to work). (5.00% on Tk. Q) : Tk. S
A. FOUNDATION COST
Quantity/Amount Unit Rate (Tk.) Total Amount
(Tk.)
1. Soil Investigation : L.S. or Actual cost 5 Nos. Tk. 16,364.00 /No. Tk. 81,820.00
(BH Nos. as primary, say)
2. Foundation cost : 371.97 sqm Tk. 12,697.59 /sqm Tk. 4,723,120.98
From PLAR Table - 1, (For B.C.qa=3ksf)
371.97 sqm @ Tk. 12,697.59 per sqm
3. Add extra 2% cost for wind (other than coastal area) & Tk. 4,723,120.98 2% Tk. 94,462.42
earthquake load:
2% on Tk 47,23,120.98
"A" = Tk. 4,899,403.40
B. SUPER STRUCTURE COST.
4. (i) Ground floor as Parking (from PLAR Table-2) 371.97 sqm Tk. 12,051.67 /sqm Tk. 4,482,857.86
371.97 sqm @ Tk. 12051.67
(ii) Add extra cost for Member Weightage (M.W.) (from 371.97 sqm Tk. 978.56 /sqm Tk. 363,995.28
PLAR Table-3.)
371.97 sqm @ Tk. 978.56 per sqm.
5. (i) 1st floor (from PLAR Table-2.) 371.97 sqm Tk. 20,314.60 /sqm Tk. 7,556,423.27
371.97 sqm @ Tk. 20314.6 per sqm
(ii) Add extra cost for M.W (from PLAR Table-3.) 371.97 sqm Tk. 980.82 /sqm Tk. 364,834.40
371.97 sqm @ Tk. 980.82 per sqm
6. (i) 2nd floor (from PLAR Table-2) 371.97 sqm Tk. 20,924.04 /sqm Tk. 7,783,115.97
371.97 sqm @ Tk. 20924.04 per sqm
(ii) Add extra cost for M.W (from PLAR Table-3) 371.97 sqm Tk. 784.65 /sqm Tk. 291,867.52
371.97 sqm @ Tk. 784.65 per sqm.
PWD SoR 2014 for Civil Works 259
7. (i) 3rd floor (from PLAR Table-2) 371.97 sqm Tk. 21,551.76 /sqm Tk. 8,016,609.45
371.97 sqm @ Tk.21551.76 per sqm
(ii) Add extra cost for M.W (from PLAR Table-3) 371.97 sqm Tk. 588.49 /sqm Tk. 218,900.64
371.97 sqm @ Tk. 588.49 per sqm.
8. (i) 4th floor (from PLAR Table-2) 371.97 sqm Tk. 22,198.32 /sqm Tk. 8,257,107.73
371.97 sqm @ Tk. 22,198.32 per sqm
(ii) Add extra cost for M.W (from PLAR Table-3) 371.97 sqm Tk. 392.33 /sqm Tk. 145,933.76
371.97 sqm @ Tk. 392.33 per sqm.
9. 5th floor (from PLAR Table-2) 371.97 sqm Tk. 22,864.27 /sqm Tk. 8,504,820.96
371.97 sqm @ Tk. 22,864.27 per sqm
"B" = Tk.45,986,466.86
10. Add extra super structure cost 2% for wind Tk. 45,986,466.86 Tk 2% Tk. 919,729.34
(other than coastal area) & earth quake load resisting
structure.):
2% on Tk 45,986,466.86
11. Extra cost for Rooftop &Chillakotha (From PLAR Table-2): 371.97 sqm Tk. 2,865.35 /sqm Tk. 1,065,824.00
371.97 sqm @ Tk. 2865.35 per sqm\
12. Extra cost for Roof top R.C. C Parapet (From Additional Cost 77.14 sqm Tk. 2,547.00 /sqm Tk. 196,424.64
Chart item-4):
4x19.28x1n=77.14sqm @ Tk. 2547.00 per sqm
13. Extra cost for Roof top R.C.C water tank (From Additional 2000 gallon Tk. 142.00 /gal Tk. 284,000.00
Cost Chart. item-5):
2000 gal. @ Tk. 142.00 per gal
"C" = Tk. 2,465,977.98
Gas Connection.
19. (i) Ground Floor. (From Additional Cost Chart item-8 (i) 185.99 sqm Tk. 342.20 /sqm Tk. 63,644.07
Consider 50% cost as parking.
0.50x371.97 sqm @ Tk. 342.20 per sqm
(ii) Other floor (From Additional Cost Chart item-8-(ii): 1859.85 sqm Tk. 136.88 /sqm Tk. 254,576.27
5x371.97 sqm @ Tk. 136.88 per sqm
20. Construction of Compound drain
Cost on running meter basis. Actual cost. Q
21. Approach Road.
R
As per required. (From Additional Cost Chart item-12-i/ii)
22. (i) Boundary Wall. As per requirement.
(From Additional Cost Chart item-11-i/ii/iii) S
(ii) Gate, Actual Cost (As per practical cost)
23. Site improvement. T
24. Testing of materials as per requrement U
25. Arboriculture/Landscape (As per requirement): V
26. Fire Fighting (As per requirement): W
sum of cost from
Total "D" =
item 14 to 26
Sub-Total "X" = (A+B+C+D)
27. Quality Assurance , Material Sample Collection & Testing ( 1% of X ) "Y" = 1% of "X"
5% of "X" Or
28. Contingency ( 5% of X ) or Actual need. "Z" =
Actual need
Grand Total = (X+Y+Z)
PWD SoR 2014 for Civil Works 261
Annexure-C
Annexure-C
SUPER FINISH SCHEDULE FOR RESIDENTIAL BUILDING
FLAT TYPE ‘D’ (1000 sft) and ‘E’ (1250 sft)
INTERIOR FINISH MATERIAL
FLOOR NAME OF THE SPACE EXTERIOR FINISH MATERIAL REMARKS
FLOOR WALLS CEILING DOORS WINDOWS
plaster Main door- Grill-5 mm
rough casting / patterned paving plaster with
PARKING with Door x 19 mm.
block plastic paint
distemper frame of flat bar
GROUND
Local best quality homogeneous plaster timber, with
plaster with
STAIR LOBBY glazed floor tiles /terrazo (in situ with Shutter- enamel
plastic paint Kitchen
or tiles) distemper solid paint
with
Local best quality homogeneous plaster wooden
plaster with Plaster with weather coat/ cabinet
TYPICAL MASTER BED glazed floor tiles /terrazo (in situ with door best
plastic paint exposed brick with pointing and
or tiles) distemper quality
ordinary
Local best quality homogeneous plaster polish. shutter-
plaster with hood.
OTHERS BED glazed floor tiles /terrazo (in situ with sliding
plastic paint aluminum
or tiles) distemper
Local best quality homogeneous plaster fabricated
plaster with
DRAWING glazed floor tiles /terrazo (in situ with Other with glass
plastic paint doors- shutter/
or tiles) distemper
PWD SoR 2014 for Civil Works 263
Bathroom
Local best quality homogeneous plaster door-
plaster with
CORRIDOOR / PASSAGE glazed floor tiles /terrazo (in situ with Wooden
plastic paint door with
or tiles) distemper
lacquer
coating
(inside)
PWD SoR 2014 for Civil Works 264
Annexure-C
SUPERIOR FINISH SCHEDULE FOR RESIDENTIAL BUILDING
FLAT TYPE ‘F’ (1500 sft ) and Superior – 1800 sft.
INTERIOR FINISH MATERIAL
FLOOR NAME OF THE SPACE EXTERIOR FINISH MATERIAL REMARKS
FLOOR WALLS CEILING DOORS WINDOWS
plaster Main door-Door
rough casting / patterned plaster with with frame of timber,
PARKING
paving block plastic paint plastic Shutter-solid
paint wooden (teak or
GROUND
plaster other timber of
Local best quality
plaster with with approved quality) Grill-5 mm
STAIR LOBBY homogeneous mirror polish
plastic paint plastic decorative door x 19 mm.
floor tiles.
paint with best quality flat bar Kitchen
plaster polish. with with
Local best quality
plaster with with enamel cabinet
MASTER BED homogeneous floor tiles
plastic paint plastic paint. and foreign
/terrazo (in situ or tiles)
paint Other doors-Door made
plaster frame of timber hood.
Local best quality
plaster with with (teak or other Shutter-
OTHERS BED homogeneous floor tiles
plastic paint plastic timber of sliding
/terrazo (in situ or tiles) Plaster with weather coat/
paint approved quality) aluminum
exposed brick with pointing
plaster fabricated M.S box or
Local best quality
plaster with with with glass G.I. stair
DRAWING homogeneous floor tiles
plastic paint plastic Shutter-Particle shutter. railing with
/terrazo (in situ or tiles)
TYPICAL paint board flush door wooden /
plaster of wood veneer G.I. hand
Local best quality with best quality Window rail of
plaster with with
DINING homogeneous floor tiles polish. frame- approved
plastic paint plastic
/terrazo (in situ or tiles) aluminum design.
paint
local best fabricated
quality Main gate- frame.
plaster MS..sheet with
Local best quality ceramic wall
with
KITCHEN homogeneous floor tiles tile/ terrazo M.S. angle/ S.S.
plastic sheet with S.S.
/terrazo (in situ or tiles) (in situ or tile)
paint pipe as per
upto 2100
mm height design.
PWD SoR 2014 for Civil Works 265
local best
plaster
quality
local best quality ceramic with
TOILET ceramic wall Bathroom door-
floor tiles plastic
tile upto Wooden door
paint
false ceiling with lacquer
plaster coating (inside)
Local best quality
plaster with with
STAIR LOBBY homogeneous mirror polish
plastic paint plastic
floor tiles.
paint
Local best quality plaster
homogeneous glazed floor plaster with with
STAIR
tiles /terrazo (in situ or tiles) plastic paint plastic
with brass of bronze nosing paint
plaster
Local best quality
plaster with with
CORRIDOOR / PASSAGE homogeneous glazed floor
plastic paint plastic
tiles /terrazo (in situ or tiles)
paint
Annexure-C
SPECIAL FINISH SCHEDULE FOR RESIDENTIAL BUILDING
FLAT TYPE – 2500 sft. and ABOVE.
FLOOR NAME OF SPACE FLOOR SKIRTING WALL CEILLING DOOR WINDOW COMMENTS
Rough & Plastic paint Plastered
textured of approved & painted
DRIVE WAY & PARKING concrete tile of color with white
approved color plastic
design & size. paint
Homogeneous Homogeneous Plastic paint Plastered Solid Aluminum sliding window Stainless
GROUND FLOOR
tiles of tiles of stair of approved & painted wooden with 6 mm x 25 mm flat M.S steel railing of
approved color color color with white door of bar grill as per design. Fly approved
STAIR with nosing plastic approved proof net. Frame: silver design with
strips/terrazo paint. design in colour anodized. Glass: light wooden or s.s
with brass roof top. brown tinted type. Grill color: hand rail.
nosing. of approved enamel paint.
PWD SoR 2014 for Civil Works 266
Annexure-C
FLOOR NAME OF SPACE FLOOR SKIRTING WALL CEILLING DOOR WINDOW COMMENTS
Annexure-C
FLOOR NAME OF SPACE FLOOR SKIRTING WALL CEILLING DOOR WINDOW COMMENTS
Wooden (Garjan
or other timber of
Aluminum sliding approved quality)
window with 6 mm x louvred catdoor
Ceramic wall 25 mm flat M.S bar direcly above door
tiles of grill as per design. with same width
Ceramic floor Plastered & Solid wooden door with
approved Fly proof net. Frame: upto ceiling
tiles (non-skid) painted with mortice lock & tower
TOILET colour & size silver colour painted with
of approved white plastic bolt. Coated with lacquer
upto bottom anodized. Glass: enamel paint of
color & size. paint paint (inside)
of false light brown tinted wall color and fly
ceiling. type. Grill color: of proof net inside.
approved enamel 38 mm high door
paint sill maids toilet
150 mm high door
sill.
Aluminum sliding
TYPICAL FLOOR window with 6 mm x
Door frame of (teak or
25 mm flat M.S bar
100 mm high Ceramic wall other timber of approved
Homogeneous grill as per design.
skirting with tiles of Plastered & quality) shutter-particle Kitchen with
tiles /terrazo Fly proof net. Frame:
homogeneous approved painted with board flush door of wood cabinet and
KITCHEN (in situ or tile) silver colour
tiles / terrazzo colour & size white plastic veneer with mortice lock, foreign made
of approved anodized. Glass:
(in situ) of upto 2100 paint tower bolt, magnetic hood.
color. light brown tinted
floor color mm height. door stopper inside room
type. Grill color: of
and best quality polish.
approved enamel
paint.
Local best
Solid wooden door of
quality 100 mm high Stainless steel
Plastic paint Plastered & (teak or other timber of
homogeneous skirting with /Mild steel railing
of approved painted with approved quality) with
VERANDAH non-skid homogeneous of approved
color on white plastic mortice lock & tower
glossy tiles of tiles of floor design with 25 mm
plaster. paint bolt. Coated with lacquer
approved color high door sill.
paint only in outside.
color.
PWD SoR 2014 for Civil Works 267
Annexure-D
NAME OF THE MATERIAL BRAND AS USER GUIDE*
(SUBJECT TO SATISFY THE STANDARD TESTS AND APPROVAL BY PWD)
SL. NAME OF THE MATERIAL AND STANDARD** BRAND NAME MANUFACTURER
1.1 ANCHOR Olympic Cement Ltd.
Green Grandeur
58/E, Kemal Ataturk Avenue(11th Floor)
Banani, Dhaka-1213
Phone: 9821503, 9821504
1.17
1.19
1.20
2.8
2.9
2.10
2.11
3.9
3.10
PWD SoR 2014 for Civil Works 270
4.2
4.3
5. uPVC PIPES FOR PORTABLE WATER 5.1 NPI National Polymer Industries Ltd.
SUPPLY AND FITTINGS 36, Lake Circus Kalabagan, Dhaka
BDS 1496:2006 Phone: 02-8115054-57
BS 3505:1986
5.2
ISO 4422-2:1996 (E)
5.3
7.4