You are on page 1of 31

GRUNDFOS DATA BOOKLET

Hydro Solo-E and Hydro Solo-E Optimum


Complete Booster Systems 50/60 Hz
Hydro Solo-E and Hydro Solo-E Optimum

1. Product introduction . . . . . . . . . . . . . . . . . . . 3
Table of contents

Features and benefits . . . . . . . . . . . . . . . . . . . . .3


Applications . . . . . . . . . . . . . . . . . . . . . . . . . . . .3
Construction of Hydro Solo-E Optimum vs.
Hydro Solo-E . . . . . . . . . . . . . . . . . . . . . . . . . . .3
Performance range . . . . . . . . . . . . . . . . . . . . . . .4
Identification. . . . . . . . . . . . . . . . . . . . . . . . . . . .6

2. Installation and operation . . . . . . . . . . . . . . . 7


Mechanical installation. . . . . . . . . . . . . . . . . . . . .7
Electrical installation . . . . . . . . . . . . . . . . . . . . . .7
Reset after water shortage . . . . . . . . . . . . . . . . . .8
Control of CRE pumps. . . . . . . . . . . . . . . . . . . . .9

3. Hydro Solo-E Optimum . . . . . . . . . . . . . . . . 11


Features and benefits of Optimum range . . . . . . . 11
Protection features . . . . . . . . . . . . . . . . . . . . . . 11
Control panel . . . . . . . . . . . . . . . . . . . . . . . . . . 12
Performance curves . . . . . . . . . . . . . . . . . . . . . 13
Technical data . . . . . . . . . . . . . . . . . . . . . . . . . 14

4. Hydro Solo-E . . . . . . . . . . . . . . . . . . . . . . . . 16
Features and benefits . . . . . . . . . . . . . . . . . . . . 16
Protection features . . . . . . . . . . . . . . . . . . . . . . 16
Control panel . . . . . . . . . . . . . . . . . . . . . . . . . . 17
Technical data . . . . . . . . . . . . . . . . . . . . . . . . . 17
Data sheets . . . . . . . . . . . . . . . . . . . . . . . . . . . 19

5. Accessories . . . . . . . . . . . . . . . . . . . . . . . . . 26
Fieldbus communication interfaces . . . . . . . . . . . 26
Grundfos GO Remote . . . . . . . . . . . . . . . . . . . . 26
Float switch . . . . . . . . . . . . . . . . . . . . . . . . . . . 26
Dry-running protection . . . . . . . . . . . . . . . . . . . . 26

6. Product numbers . . . . . . . . . . . . . . . . . . . . . 27

2
Hydro Solo-E and Hydro Solo-E Optimum
1

Product introduction
1. Product introduction
Applications
Hydro Solo-E is designed for systems where it is crucial to
keep a constant pressure. This makes Hydro Solo-E
suitable for these applications:
• Cluster homes
• blocks of flats
• schools
• hotels or guest houses
• office buildings

TM076248
• industrial water supply systems
• water treatment systems

Left to right: Hydro Solo-E, Hydro Solo-E Optimum • water filtration systems
• small industries

Hydro Solo-E Optimum • washing and cleaning systems.


The Hydro Solo-E Optimum is a fully-optimised package
with constant pressure control, flow estimation and plug-
Construction of Hydro Solo-E
and-pump installation for immediate, always-optimised Optimum vs. Hydro Solo-E
operation. The graphical display built into the pump
provides a real-time overview of booster set performance. Hydro Solo-E
Hydro Solo-E
Optimum
Pump CRE CRIE
Hydro Solo-E
Suction manifold - ✓
The Hydro Solo-E booster system is a turnkey solution Discharge manifold ✓ ✓
enabling you to keep a constant pressure in your system
Dry-running protection -* ✓
at all times. Hydro Solo-E consists of a Grundfos CRE
pump fitted with isolating valve, non-return valve, outlet Base plate - ✓
pipe, pressure transmitter, pressure gauge and pressure Vibration dampers - ✓
tank. Hydro Solo-E is ready for operation on delivery. Non-return valve ✓ ✓
Isolating valve ✓ ✓
Features and benefits Pressure transmitter ✓ ✓
• Easy installation. Pressure gauge ✓ -

• Constant pressure. Pressure tank with


✓ ✓
FlowJet
• Speed-controlled pump. Graphical display - ✓
• Low energy consumption.
* Dry-running protection can be added to Hydro Solo-E variants as an accessory.
• No need for motor protection.
• Compact design.

3
1 Hydro Solo-E and Hydro Solo-E Optimum

Performance range
Product introduction

Hydro Solo-E Optimum

p H
[kPa] [m]
1200
120 Hydro Solo-E Optimum
1100 CR 5-9
110

1000
100

900 90

800 80

700 70

600 60

500 50

400 40
CR 15-3
300 30
CR 5-7 CR 15-2
CR 10-3
200 20
CR 10-3
CR 5-5
100 10 CR 3-7

0 0
0 2 4 6 8 10 12 14 16 18 20 22 24 26 Q [m³/h]

TM070142
0 1 2 3 4 5 6 7 Q [l/s]

Hydro Solo-E Optimum performance range

4
Hydro Solo-E and Hydro Solo-E Optimum
1

Product introduction
Hydro Solo-E

H
[m]
Hydro Solo-E
150 50/60 Hz
ISO 9906:2012 Grade 3B

100

90

80

70

60
CRE 1

50
CRE 3

40
CRE 5

30
CRE 10

CRE 15

20
CRE 20

CRE 32

CRE 45

15
CRE 64

CRE 90

10
1 2 3 4 6 8 10 20 30 40 60 80 100 200
Q [m³/h]
TM059028

Hydro Solo-E performance range

5
1 Hydro Solo-E and Hydro Solo-E Optimum
Product introduction

Identification
Type key
Example: HYDRO SOLO-E CRE 15-3 U8 A- A- A- A- ABCDE

Code Designation Explanation


HYDRO SOLO Product name
E System type E: The motor has a built-in frequency converter
CRE X-Y CRE: Cast iron and stainless materials
CRIE: Stainless materials only
Pump model
CRIE X-Y X: Flow rate m3/h
Y: Number of impellers
U2 3 x 380 - 500 V, PE, 50/60 Hz
U7 1 x 200 - 240 V, PE, 50/60 Hz
Supply voltage
U8 1 x 200 - 240 V, N, PE, 50/60 Hz
UX Custom voltage rating (CSU variant)
A Standard range
Pump design
C OPTIMUM
A Starting method Electronic (frequency converter)
A Stainless steel outlet manifold
B Stainless steel outlet manifold and stainless steel inlet manifold
C Material combination Galvanised steel manifold
D Galvanised steel manifold and base frame
X Customised
A ACS-approved components
B Belgaqua-approved components
D DVGW-approved components
K Drinking water approvals KIWA-approved components
N NFS-approved components
V WRAS-approved components
Y No special approval
A Standard hydraulics
B Base frame
C Base frame with machine shoes
D Sensor as dry-running protection
E Pressure switch as dry-running protection
F Level switch for dry-running protection
G Option CIM module included
H Without non-return valve
L Non-return valve on the inlet side
M Pressure gauge on the inlet side
S CSU variant
U Undersized motor
X More than five options

6
Hydro Solo-E and Hydro Solo-E Optimum
2

Installation and operation


2. Installation and operation
Mechanical installation Electrical installation
Location The 4.0 - 7.5 kW motors must be connected to
The booster system is not designed for outdoor especially reliable and sturdy earth connections due to
installation and must not be exposed to direct sunlight. an earth leakage current above 3.5 mA.
Allow sufficient clearance around the booster system to
enable the operator to work freely. Enclosure class: Do not switch the power on/off more than four times a
IP55. Insulation class: F. day.
Install the booster system in a well-ventilated room to
ensure sufficient cooling of the pump. The electrical installation and protection must be carried
out in accordance with local regulations.
Pipes
The system in which Hydro Solo-E is incorporated must • The pump must always be correctly earthed.
be designed for the maximum pump pressure. The pipes • The pump requires no external motor protection. The
connected to the booster system must be of adequate motor incorporates thermal protection against slow
size. To avoid resonance, expansion joints must be fitted overloading and blocking.
both in the outlet and inlet pipes. Connect the pipes to the
outlet pipe and the pump inlet port. Additional protection
Tighten the booster system before startup. We Connecting the pump to an electric installation with an
recommend fitting pipe supports on the inlet and outlet earth leakage circuit breaker (ELCB) is not a requirement.
side. However, if you choose to use this additional protection,
the earth leakage circuit breakers must be marked with
the following symbols:

Single-phase

TM072868
2

2 1 1 2
TM010227

The earth leakage circuit breakers must trip out when


earth fault currents with DC content (pulsating DC) occur.
Pipes
1 x 200-240V, +/- 10%
Foundation On/off switch

Position the booster system on an even and solid surface, Max. 10 A


N N
such as a concrete floor or foundation. If the booster
ELCB PE
system is not fitted with vibration dampers, bolt it to the
floor or foundation. L L
TM020792
PE
Pressure tank
The pressure tank is pre-charged to the correct pressure.
If the setpoint is altered, a new pre-charge pressure must
be calculated to obtain the optimum duty. Wiring diagram, single phase
Calculation of pre-charge pressure: pre-charge pressure
is equal to 0.7 x setpoint. Measure the pre-charge
pressure of the pressure tank in a pressureless system.
We recommend that you refill the tank with nitrogen.

7
2 Hydro Solo-E and Hydro Solo-E Optimum

Three-phase Float switch


Installation and operation

It is optional to add a float/level switch to Hydro Solo-E

TM072869
and Hydro Solo-E Optimum systems.
Hydro Solo-E Optimum
For more information on adding the float/level switch to
The earth leakage circuit breakers must trip out when Hydro Solo-E Optimum and to access the wiring diagram,
earth fault currents with DC content (pulsating DC) and scan the QR code to access the quick guide:
smooth DC earth fault currents occur.

3 x 400V, +/- 10%


On/off switch

QR99838821
Max. 10 A
L1 L1
L2 L2
L3 L3

TM009270
PE net.grundfos.com/qr/i/99838821

Hydro Solo-E
Wiring diagram, three-phase, 2.2-7.5 kW For more information on adding the float/level switch to
Hydro Solo-E and to access the wiring diagram, scan the
QR code to access the quick guide:

QR98475844
net.grundfos.com/qr/i/98475844
Reset after water shortage
Automatic reset
Level switch

CRE pump
Pressure
switch
CRE pump
PS

CRE pump

CRE pump LS
1 digital input
PS
1 digital input 2 start/stop

3 GND (frame)
TM022589

2 start/stop

3 GND (frame)
TM022560

Automatic reset with float/level switch

Automatic reset with pressure switch

8
Hydro Solo-E and Hydro Solo-E Optimum
2
Manual reset Control of CRE pumps

Installation and operation


Communication with CRE pumps
Pressure
Communication with CRE pumps is possible via:
switch
CRE pump • A central building management system
PS
• Grundfos GO Remote
• a control panel.
Central building management system
The operator can communicate with a CRE pump at a
CRE pump
distance. Communication can take place via a central
PS
building management system allowing the operator to
1 digital input
monitor and change control modes and setpoint settings.
The communication interface between the CRE pump and
central building management systems varies depending
on the pump size.
3 GND (frame)

TM022561

Manual reset with pressure switch

TM056174
Level switch

CRE pump net.grundfos.com/qr/i/98358864

Grundfos GO Remote support


With Grundfos GO Remote, you can monitor the product,
change settings, collect data and make reports. A user-
friendly interface provides you with all the information and
CRE pump help you need, as well as live pump data monitoring and
easy-to-follow tips and guides.
LS You can use Grundfos GO Remote for the following
1 digital input functions:
• reading operating data
3 GND (frame) • reading warning and alarm indicators
TM022590

• setting the control mode and the application (emptying


or filling)
• setting the control mode
Manual reset with float/level switch
and the application (dewatering or filling)
• setting the time (real-time clock)
• setting the user-configurable log
• storing and recalling configuration.

9
2 Hydro Solo-E and Hydro Solo-E Optimum

Grundfos GO Remote
Installation and operation

The product is designed for wireless radio or infrared


communication with Grundfos GO Remote.
Grundfos GO Remote enables you to set functions and
gives you access to status overviews, technical product
information and current operating parameters.
Use Grundfos GO Remote together with this mobile
interface:
• Grundfos MI 301.

+
TM066256

Pos. Description
Grundfos MI 301:
1 Separate module enabling radio or infrared communication. Use
the module together with an Android or iOS-based smart device via
a Bluetooth connection.

10
Hydro Solo-E and Hydro Solo-E Optimum
3

Hydro Solo-E Optimum


3. Hydro Solo-E Optimum
Features and benefits of Optimum
range
Easy installation
Hydro Solo-E Optimum is fully pre-assembled, enabling a
quick and easy installation. The system needs to be
connected, primed and then it is ready for operation.
Compactness of the system reduces the space needed in
installation.

Low energy consumption

TM076324
The Grundfos E-motor with a built-in frequency converter
enables variable speed operation and high efficiency,
resulting in extensive energy savings.
Hydro Solo-E Optimum Motor protection
The Hydro Solo-E systems require no external motor
The Grundfos Hydro Solo-E Optimum booster system is a protection. The motor incorporates thermal protection
turnkey solution enabling you to keep constant pressure in against slow overloading and blocking.
your system at all times. Pre-programmed functions
Hydro Solo-E Optimum consists of the following:
• Pressure boosting - Home display.
• inline vertical multistage centrifugal (CRIE) pump with
IE5 motor and integrated VFD with graphical display • Constant pressure control.

• isolating valves for easy maintenance of the system • Low-flow stop activated - setup according to tank size.

• analog pressure sensor for monitoring of inlet • Stop at minimum speed activated (30 sec).
conditions and prevention of dry running of the pump • Dry-running protection activated (0.5 bar - adjustable).
• inlet and outlet manifold in stainless steel • Flow estimation.
• analog pressure sensor for monitoring and control of • Anti-cavitation protection (flow limit).
discharge pressure
• Alarm/Pump running signal relays.
• main switch
Grundfos GO Remote
• non-return valve for prevention of backflow when the
pump is stopped The product is designed for Bluetooth communication with
Grundfos GO Remote.
• pressurised diaphragm tank to enable the stopping of
Grundfos GO Remote enables you to set functions and
the pump at low flow to increase system efficiency
gives you access to status overviews, technical product
• flowjet valve – special ball valve for pressure tank information and current operating parameters.
connection to ensure water circulation inside the tank
• stainless-steel, factory-mounted baseplate with Protection features
vibration dampers.
Dry-running protection
The product incorporates dry-running protection that
automatically stops the pump from running without
liquid. Dry-running protection means less risk of pump
damage and lower maintenance costs.

Anti-cavitation
The pump comes pre-programmed with a flow limit to
protect against cavitation.

Pump Non-return
valve
TM076293

Pressure Isolating
transmitter valve

Schematic of Hydro Solo-E Optimum

11
3 Hydro Solo-E and Hydro Solo-E Optimum

Control panel Home display


Hydro Solo-E Optimum

Hydro Solo-E Optimum 1 2 3 4

Home Status Settings Assist


1
Setpoint Control mode

5.00 bar Const. pressure


2
Operating mode Actual controlled value

6 Normal
3 4.90 bar
4 1 2 3

TM064516
TM054849
Status Settings Assist
9 8 7 6 5
Setpoint Control mode

Pos. Symbol Description


Pos. Symbol Description 5.00 bar Const. pressure
Home: This menu shows up to four user-defined
Grundfos Eye:
1 parameters. You can access each parameter directly from
1 The indicator light shows the operating status of the this menu. Operaring mode Actual controlled value
product.
Status: This 1menu shows the status of the product
2 3
and
2 - Normal
2 - Graphic colour display. system, warnings and alarms. 4.90 bar
Back: Settings: This
3 1 menu gives access to all setting
2 3
Press the button to go one step back. 3 - parameters. The menu also allows you toStatus
make detailed
Settings Assist
settings.
Left/Right: Press the buttons to navigate between main
Setpoint Control mode
menus, displays and digits. When you change the menu, Assist: This 1
menu enables assisted setup, 2provides3a
the display shows the top display of the new menu. 4 - short description of the control modes andStatus
offers Settings
fault- Assist

Up/Down:
finding advice. 5.00 bar
Setpoint
Const.
9 8 7 6 5
pressure
Control mode
Press the buttons to navigate between submenus or Start/Stop: The
1 icon indicates that the product
2 was 3
5
change the value settings. 5.00 bar
stopped with the Start/Stop button.
Operaring mode
Const.Settings
Status pressure Assist
Actual controlled value
If you have disabled the possibility to make settings with Master: The icon indicates that the product
Setpoint is functioning
Control mode
the Enable/disable settings function, you can enable it Normal
again temporarily by pressing these buttons
6 as the master1 in a system
and size. 5.00 bar
Operaring mode 4.90 bar
with products of the
2 same3type
Const.
Status
Actual pressure
Settings
controlled
Assist
value
simultaneously for at least 5 seconds.
Slave: The icon indicates that the product
Setpoint is functioning
Control mode
Normal
OK: 7 4.90 bar
as a slave in a system with products of the same type
Status Settings Assist
4 Press the button to do the following: and size. 5.00 bar
Operaring mode Const. pressure
Actual controlled value
• Save changed values, reset alarms and expand the Setpoint
Multioperation: Control
The icon indicates that the mode
product is
Normal
value field. 8 operating in a system with products
9 of 8 the 4.90 bar
7 same
6 5 type and
• Enable radio communication with Grundfos GO
Remote and other products of the same type.
size. 5.00 bar
Operaring mode Const.
Actual pressure
controlled value

Normal
Lock: The icon indicates that the possibility to make
When you try to establish radio communication between
the product and Grundfos GO Remote or another
9 9 8 7 6 5 4.90 bar
settings has been disabled for protective reasons.
Operaring mode Actual controlled value
product, the green indicator light in Grundfos Eye flashes.
In the controller display, a note states that a wireless Normal
device wants to connect to the product. Press OK on the
9 8 4.90 bar
7 6 5
product operating panel to allow radio communication
with Grundfos GO Remote and other products of the
same type. 9 8 7 6 5
Start/Stop: Press the button to make the product ready
for operation or to start and stop the product.Start: If you
press the button when the product is stopped, the product 9 8 7 6 5
5 starts if no other functions with higher priority have been
enabled.Stop: If you press the button when the product is
running, the product always stops.When you press the
button, the stop icon appears at the bottom of the display.

6 Home: Press the button to go to the Home menu.

12
Hydro Solo-E and Hydro Solo-E Optimum
3

Performance curves

Hydro Solo-E Optimum


p H
[kPa] [m]
1200
120 Hydro Solo-E Optimum
1100 CR 5-9
110

1000
100

900 90

800 80

700 70

600 60

500 50

400 40
CR 15-3
300 30
CR 5-7 CR 15-2
CR 10-3
200 20
CR 10-3
CR 5-5
100 10 CR 3-7

0 0
0 2 4 6 8 10 12 14 16 18 20 22 24 26 Q [m³/h]

TM070142
0 1 2 3 4 5 6 7 Q [l/s]

Hydro Solo-E Optimum performance range

13
3 Hydro Solo-E and Hydro Solo-E Optimum

Technical data
Hydro Solo-E Optimum

Dimensions and weights

DN1 DN2

H1
H2

TM071315
L2 L1 W2 W1
L W

Dimensions
Pump type H H1 H2 W W1 W2 L L1 L2
CRIE 3-7 611 465 112 403 244 159 912 568 344
CRIE 5-5 620 465 112 403 244 159 912 568 344
CRIE 5-7 710 465 112 403 244 159 912 568 344
CRIE 5-9 804 465 112 403 244 159 912 568 344
CRIE 10-3 739 465 142 479 259 220 969 599 370
CRIE 15-2 816 465 152 467 259 208 1188 681 507
CRIE 15-3 861 465 152 467 259 208 1188 681 507

Weights
Pump type Net Weight [kg] Gross Weight [kg]
CRIE 3-7 41 50
CRIE 5-5 44 52
CRIE 5-7 48 57
CRIE 5-9 48 57
CRIE 10-3 70 84
CRIE 15-2 79 103
CRIE 15-3 79 103

Electrical data

Pump Type Motor [kW] Full-Load Current [A] Supply Voltage [V] Tank Volume [l] Connection In/Outlet
CRIE 3-7 0.75 4.70-3.90 1 x 200-240 V 18 Rp 1" 1/4
CRIE 5-5 1.1 6.70-5.60 1 x 200-240 V 18 Rp 1" 1/4
CRIE 5-7 1.5 9.10-7.60 1 x 200-240 V 18 Rp 1" 1/4
CRIE 5-9 2.2 4.15-3.40 3 x 380-500 V 18 Rp 1" 1/4
CRIE 10-3 1.5 9.10-7.60 1 x 200-240 V 18 Rp 1" 1/2
CRIE 10-3 2.2 4.15-3.40 3 x 380-500 V 18 Rp 1" 1/2
CRIE 15-2 3.0 6.20-5.00 3 x 380-500 V 18 Rp 2"
CRIE 15-3 4.0 7.60-6.50 3 x 380-500 V 18 Rp 2"

14
Hydro Solo-E and Hydro Solo-E Optimum
3
Operating temperature Construction of Hydro Solo-E Optimum

Hydro Solo-E Optimum


Liquid temperature 0-60 °C
System components
Ambient temperature CRE 0.37 - 11 kW 0-50 °C The inlet side is fitted with a stainless steel inlet pipe
(EN/DIN 1.4401 or EN/DIN 1.4571) and a non-return
Minimum inlet pressure valve. The inlet pipe is fitted with a isolating valve and a
inlet pressure sensor.
The minimum inlet pressure H in metres head required to
The outlet side of the pump is fitted with a isolation valve,
avoid cavitation in the pump is calculated as follows:
flow jet valve and pressure tank.
H = Pb x 10.2 - NPSH - Hf - Hv - Hs The pump is fitted with and off/on switch for supply
= Barometric pressure in bar. voltage, a discharge pressure sensor and a graphical
Pb Barometric pressure can be set to display.
1, if required.
= Net Positive Suction Head in
metres head. NPSH can be read
NPSH from the NPSH curve at the
maximum capacity at which the
1
pump will run.
8
= Friction loss in inlet pipe in metres
Hf
head.
Hv = Vapour pressure in metres head.
9
= Safety margin of minimum 0.5
Hs
metres head. 13 2

Maximum inlet and system pressures 7

Hydro Solo-E Maximum inlet System pressure


Optimum pressure [bar] [bar] 10

CRIE 3-7 6 10 12
CRIE 5-5 6 10 11
CRIE 5-9 6 16
CRIE 10-3 6 10 3
CRIE 15-2 6 10
CRIE 15-3 6 10

TM076356
6 5 4

Pos. Description Quantity


CRIE pump with
1 1
graphical display
2 Pressure tank 1
Flow jet valve for
3 1
pressure tank
4 Isolating valve 1
Outlet pipe, stainless
5 1
steel
Base plate with
6 1
vibration dampers
Discharge pressure
7 1
sensor
8 Inlet pressure sensor 1
9 Isolating valve 1
Inlet pipe, stainless
10 1
steel
11 On/Off switch 1
12 Non-return valve 1
13 Nameplate 1

15
4 Hydro Solo-E and Hydro Solo-E Optimum
Hydro Solo-E

4. Hydro Solo-E
Features and benefits
• Easy installation.
• Constant pressure.
• Speed-controlled pump.
• Low energy consumption.
• No need for motor protection.
• Compact design.

TM076249
Easy installation
Hydro Solo-E Optimum is fully pre-assembled, enabling a
Hydro Solo-E quick and easy installation. The system needs to be
connected, primed and then it is ready for operation.
Compactness of the system reduces the space needed in
The Grundfos Hydro Solo-E booster system is a turnkey installation.
solution enabling you to keep a constant pressure in your
system at all times. Hydro Solo-E consists of a Grundfos Motor protection
CRE pump fitted with isolating valve, non-return valve, The Hydro Solo-E systems require no external motor
outlet pipe, pressure transmitter, pressure gauge and protection. The motor incorporates thermal protection
pressure tank. Hydro Solo-E is ready for operation on against slow overloading and blocking.
delivery.
Grundfos GO Remote
The product is designed for Bluetooth communication with
Grundfos GO Remote.
Grundfos GO Remote enables you to set functions and
gives you access to status overviews, technical product
information and current operating parameters.

Protection features
Dry-running protection
The product incorporates dry-running protection that
automatically stops the pump from running without
liquid. Dry-running protection means less risk of pump
damage and lower maintenance costs.

Anti-cavitation
The pump comes pre-programmed with a flow limit to
Pump Non-return Isolating protect against cavitation.
valve valve
TM008427

Pressure
transmitter

Schematic of Hydro Solo-E

16
Hydro Solo-E and Hydro Solo-E Optimum
4

Control panel Technical data

Hydro Solo-E
Hydro Solo-E Operating temperature
Liquid temperature 0-60 °C
Ambient temperature CRE 0.37 - 11 kW 0-50 °C
1
Minimum inlet pressure
2 The minimum inlet pressure H in metres head required to
avoid cavitation in the pump is calculated as follows:

H = Pb x 10.2 - NPSH - Hf - Hv - Hs
= Barometric pressure in bar.
3 Pb Barometric pressure can be set to
1, if required.
= Net Positive Suction Head in
4 metres head. NPSH can be read
Stop NPSH from the NPSH curve at the
maximum capacity at which the
5 pump will run.

TM054848 Hf
= Friction loss in inlet pipe in metres
head.
Hv = Vapour pressure in metres head.
= Safety margin of minimum 0.5
Pos. Symbol Description Hs
metres head.
Grundfos Eye: The indicator light shows the operating
1
status of the product.
2 - Light fields for setpoint indication.

3 Up/Down: The buttons change the setpoint.

Radio communication: The button enables radio


4 communication with Grundfos GO Remote and other
products of the same type.
Start/Stop: Press the button to make the product ready
for operation or to start and stop the product.Start: If you
press the button when the product is stopped, the product
5 starts if no other functions with higher priority have been
enabled.Stop: If you press the button when the product is
running, the product always stops. When you press the
button, the stop icon appears at the bottom of the display.

17
4 Hydro Solo-E and Hydro Solo-E Optimum

Maximum inlet and system pressures Construction of Hydro Solo-E


Hydro Solo-E

International range System Components


Pump type
Maximum inlet System pressure The outlet side of the pump is fitted with a non-return
pressure [bar] [bar] valve, a stainless-steel outlet pipe (EN/DIN 1.4401 or
CRE 1-4, 1-9 10 10 EN/DIN 1.4571), and an isolating valve. The outlet pipe is
CRE 1-13, 1-17 10 16 fitted with a pressure transmitter and an isolating valve for
10 10
the pressure gauge and the pressure tank. The pump is
CRE 3-4, 3-8, 3-11
fitted with an on/off switch for the supply voltage.
CRE 3-11, 3-15 10 16

CRE 5-2, 5-5, 5-9 10 10


CRE 5-12 10 16

CRE 10-1, 10-3 8 10


1
CRE 10-5 10 10

CRE 15-2 8 10
CRE 15-3, 15-4 10 10
CRE 20-2, 20-3 10 10 10

CRE 32-2-2 4 10
CRE 45-1 4 10
2
Southern European range
Maximum inlet System pressure
Pump type
pressure [bar] [bar]
9
CRE 1-4, 1-6, 1-9,
10 16
1-13, 1-17
CRE 3-4, 3-5, 3-8,
10 16
3-11, 1-15
3
CRE 5-2, 5-4, 5-5, 5-9 10 10
4
CRE 5-12 15 16
CRE 10-1, 10-2, 10-3, 8 10
10-5 5
CRE 10-6 15 10

TM027562
CRE 15-2 8 10
CRE 15-3, 15-4 10 10 8 7 6

CRE 20-2, 20-3 10 10


CRE 32-2-2 4 10 Hydro Solo-E
CRE 45-1 4 10

Pos. Description Quantity


1 CRE pump 1
2 Pressure tank 1
3 Pressure gauge 1
Isolating valve for
4 pressure tank and 1
pressure gauge
5 Isolating valve 1
Outlet pipe, stainless
6 1
steel
7 Pressure transmitter 1
8 Non-return valve 1
9 On/off switch 1
10 Nameplate 1

18
Hydro Solo-E and Hydro Solo-E Optimum
4

Data sheets Electrical data

Hydro Solo-E
International range
Hydro Solo-E with CRE1
Full-load Supply Voltage
Pump type Motor [kW]
current [A] [V]
CRE 1-4 0.37 2.40 - 2.10 1 x 200-240 V
p H
[kPa] [m] CRE 1-6 0.55 3.45 - 2.90 1 x 200-240 V
150 Hydro Solo-E CRE 1-9 0.75 4.70 - 3.90 1 x 200-240 V
1400 140 CRE 1
ISO 9906:2012 Grade 3B CRE 1-13 1.10 6.70 - 5.60 1 x 200-240 V
130
1200 120 CRE 1-13 CRE 1-17 1.50 9.10 - 7.60 1 x 200-240 V
110
1000 100 Southern European range
90 Full-load Supply Voltage
CRE 1-9 Pump type Motor [kW]
800 80 current [A] [V]
70 NPSH CRE 1-6 0.55 3.45 - 2.90 1 x 200-240 V
600 60 [m]
CRE 1-6 CRE 1-9 0.75 4.70 - 3.90 1 x 200-240 V
50 5
CRE 1-13 1.10 6.70 - 5.60 1 x 200-240 V
400 40 4
30 3
200 20 2 Dimensions and weights
10 NPSH 1
0 0 0
0.0 0.5 1.0 1.5 2.0 2.5 Q [m³/h]

0.0 0.2 0.4 0.6 Q [l/s]


P2
H

[kW]

H1
1.2
1.0 -13
DN1
DN2
0.8
-9

TM058437
H2
0.6
-6
L2 L1 W2 W1
0.4
L W
0.2
0.0
TM059020

0.0 0.5 1.0 1.5 2.0 2.5 Q [m³/h]

International range
Net Gross
Pump Tank Connection
weight weight H [mm] H1 [mm] H2 [mm] W [mm] W1 [mm] W2 [mm] L [mm] L1 [mm] L2 [mm]
type Volume [l] Inlet/Outlet
[kg] [kg]
CRE 1-4 18 Rp 1" 1/4 38 41 486 465 50 384 244 140 749 591 102
CRE 1-6 18 Rp 1" 1/4 48 51 522 465 50 384 244 140 749 591 102
CRE 1-9 18 Rp 1" 1/4 50 53 582 465 50 384 244 140 749 591 102
CRE 1-13 12 Rp 1" 1/4 45 54 654 466 50 384 244 115 749 591 102
CRE 1-17 12 Rp 1" 1/4 48 51 762 466 50 383 244 115 673 591 102

Southern European range


Net Gross
Pump Tank Connection
weight weight H [mm] H1 [mm] H2 [mm] W [mm] W1 [mm] W2 [mm] L [mm] L1 [mm] L2 [mm]
type Volume [l] Inlet/Outlet
[kg] [kg]
CRE 1-6 18 Rp 1" 1/4 57 77 522 649 50 377 237 140 713 555 102
CRE 1-9 18 Rp 1" 1/4 59 79 582 649 50 377 237 140 713 555 102
CRE 1-13 12 Rp 1" 1/4 62 82 654 649 50 377 237 140 713 555 102

19
4 Hydro Solo-E and Hydro Solo-E Optimum

Hydro Solo-E with CRE3 Electrical data


Hydro Solo-E

International range
Full-load Supply Voltage
p H Pump type Motor [kW]
current [A] [V]
[kPa] [m]
160 Hydro Solo-E CRE 3-4 0.55 3.45 - 2.90 1 x 200-240 V
150 CRE 3 CRE 3-5 0.75 4.70 - 3.90 1 x 200-240 V
1400 140 CRE 3-15 ISO 9906:2012 Grade 3B
CRE 3-8 1.10 6.70 - 5.60 1 x 200-240 V
130
1200 120 CRE 3-11 1.50 9.10 - 7.60 1 x 200-240 V
110 CRE 3-11 CRE 3-15 2.20 4.15 - 3.4 3 x 380-500 V
1000 100
90
Southern European range
800 80 CRE 3-8
Full-load Supply Voltage
70 NPSH Pump type Motor [kW]
600 current [A] [V]
60 [m]
50 5 CRE 3-8 1.10 6.70 - 5.60 1 x 200-240 V
400 40 4 CRE 3-11 1.50 9.10 - 7.60 1 x 200-240 V
30 3
CRE 3-15 2.20 4.15 - 3.40 3 x 380-500 V
200 20 NPSH 2
10 1
0 0 0 Dimensions and weights
0.0 0.8 1.6 2.4 3.2 4.0 4.8 Q [m³/h]

0.0 0.2 0.4 0.6 0.8 1.0 1.2 1.4 Q [l/s]


P2
[kW]

1.6
-15
H

H1
-11
1.2
-8
0.8 DN1
DN2

TM058437
0.4

H2
L2 L1 W2 W1
0.0 L W
TM059021

0.0 0.8 1.6 2.4 3.2 4.0 4.8 Q [m³/h]

International range
Net Gross
Pump Tank Connection
weight weight H [mm] H1 [mm] H2 [mm] W [mm] W1 [mm] W2 [mm] L [mm] L1 [mm] L2 [mm]
type Volume [l] Inlet/Outlet
[kg] [kg]
CRE 3-4 18 Rp 1" 1/4 38 41 486 465 420 420 244 140 749 591 102
CRE 3-5 18 Rp 1" 1/4 41 44 510 465 420 420 244 140 749 591 102
CRE 3-8 18 Rp 1" 1/4 43 51 606 465 50 384 244 140 749 591 104
CRE 3-11 12 Rp 1" 1/4 48 74 654 466 50 384 244 115 749 591 104
CRE 3-15 12 Rp 1" 1/4 58 64 813 466 420 420 244 115 749 591 102

Southern European range


Net Gross
Pump Tank Connection
weight weight H [mm] H1 [mm] H2 [mm] W [mm] W1 [mm] W2 [mm] L [mm] L1 [mm] L2 [mm]
type Volume [l] Inlet/Outlet
[kg] [kg]
CRE 3-8 25 Rp 1" 1/4 59 79 564 649 50 377 237 140 713 555 102
CRE 3-11 25 Rp 1" 1/4 65 85 654 649 50 377 237 140 713 555 102
CRE 3-15 25 Rp 1" 1/4 69 89 726 649 50 377 237 140 713 555 102

20
Hydro Solo-E and Hydro Solo-E Optimum
4
Hydro Solo-E with CRE5 Electrical data

Hydro Solo-E
International range
Full-load Supply Voltage
p H Pump type Motor [kW]
current [A] [V]
[kPa] [m]
160 Hydro Solo-E CRE 5-2 0.55 3.45 - 2.90 1 x 200-240 V
150 CRE 5 CRE 5-5 1.50 9.10 - 7.60 1 x 200-240 V
1400 140 CRE 5-14 ISO 9906:2012 Grade 3B
CRE 5-9 2.20 4.15 - 3.40 3 x 380-500 V
130
1200 CRE 5-12 CRE 5-12 3.00 6.20 - 5.00 3 x 380-500 V
120
110 CRE 5-14 3.00 5.80 - 4.80 3 x 380-480 V
1000 100
CRE 5-9
90
Southern European range
800 80
Full-load Supply Voltage
70 Pump type Motor [kW]
600 current [A] [V]
60
CRE 5-5 CRE 5-5 1.50 9.10 - 7.60 1 x 200-240 V
50 NPSH
400 40 [m] CRE 5-9 2.20 4.15 - 3.40 3 x 380-415 V
30 6
CRE 5-12 3.00 6.20 - 5.00 3 x 380-415 V
200 20 4
10 2 CRE 5-14 3.00 5.80 - 4.80 3 x 380-480 V
NPSH
0 0 0
0 1 2 3 4 5 6 7 8 9 Q [m³/h] Dimensions and weights
0.0 0.5 1.0 1.5 2.0 2.5 Q [l/s]
P2
[kW]
3.0 -14
-12
2.5
-9
H

2.0

H1
1.5
-5
1.0 DN1
DN2
0.5

TM058437
H2
0.0
L2 L1 W2 W1
TM059022

0 1 2 3 4 5 6 7 8 9 Q [m³/h]
L W

International range
Net Gross
Pump Tank Connection
weight weight H [mm] H1 [mm] H2 [mm] W [mm] W1 [mm] W2 [mm] L [mm] L1 [mm] L2 [mm]
type Volume [l] Inlet/Outlet
[kg] [kg]
CRE 5-2 18 Rp 1" 1/4 44 47 468 465 420 420 244 140 749 591 102
CRE 5-5 18 Rp 1" 1/4 53 55 591 465 50 384 244 140 749 591 102
CRE 5-9 18 Rp 1" 1/4 99 101 738 465 50 384 244 140 749 591 104
CRE 5-12 12 Rp 1" 1/4 73 76 884 649 50 377 237 140 756 555 102
CRE 5-14 12 Rp 1" 1/4 60 69 938 466 50 384 244 115 792 591 102

Southern European range


Net Gross
Pump Tank Connection
weight weight H [mm] H1 [mm] H2 [mm] W [mm] W1 [mm] W2 [mm] L [mm] L1 [mm] L2 [mm]
type Volume [l] Inlet/Outlet
[kg] [kg]
CRE 5-5 25 Rp 1" 1/4 64 84 591 649 50 377 237 140 713 555 102
CRE 5-9 25 Rp 1" 1/4 67 87 739 649 50 377 237 140 713 555 102
CRE 5-12 25 Rp 1" 1/4 85 105 884 649 50 377 237 140 756 555 102
CRE 5-14 25 Rp 1" 1/4 56 74 938 466 50 384 244 115 792 591 102

21
4 Hydro Solo-E and Hydro Solo-E Optimum

Hydro Solo-E with CRE10 Electrical data


Hydro Solo-E

International range
Full-load Supply Voltage
p H Pump type Motor [kW]
current [A] [V]
[kPa] [m]
Hydro Solo-E CRE 10-1 0.75 4.70 - 3.90 1 x 200-240 V
110
1000 CRE 10 CRE 10-3 2.20 4.15 - 3.40 3 x 380-500 V
100 ISO 9906:2012 Grade 3B
CRE 10-6
CRE 10-5 3.00 6.20 - 5.00 3 x 380-500 V
90
CRE 10-6 4.00 7.60 - 6.20 3 x 380-500 V
800 80
CRE 10-5
70 Southern European range
600 60 Full-load Supply Voltage
Pump type Motor [kW]
current [A] [V]
50
CRE 10-3 CRE 10-3 2.20 4.15 - 3.40 3 x 380-480 V
400 NPSH
40
[m] CRE 10-5 3.00 6.20 - 5.00 3 x 380-480 V
30 6
CRE 10-6 4.00 8.10 - 6.60 3 x 380-480 V
200 20 4

10 NPSH 2 Dimensions and weights


0 0 0
0 2 4 6 8 10 12 Q [m³/h]

0 1 2 3 4 Q [l/s]
P2
[kW] H

3.5 -6

H1
3.0 -5
2.5
DN1
2.0 DN2
-3
1.5

TM058437
H2
1.0 L2 L1 W2 W1
0.5 L W
0.0
TM059023

0 2 4 6 8 10 12 Q [m³/h]

International range
Net Gross
Pump Tank Connection
weight weight H [mm] H1 [mm] H2 [mm] W [mm] W1 [mm] W2 [mm] L [mm] L1 [mm] L2 [mm]
type Volume [l] Inlet/Outlet
[kg] [kg]
CRE 10-1 18 Rp 1" 1/2 58 61 561 495 80 399 259 140 785 627 127
CRE 10-3 18 Rp 1" 1/2 62 89 667 495 80 424 259 140 785 627 127
CRE 10-5 33 Rp 1" 1/2 83 86 792 578 80 456 259 177 828 627 127
CRE 10-6 12 Rp 1" 1/2 78 103 822 496 80 427 259 115 828 627 127

Southern European range


Net Gross
Pump Tank Connection
weight weight H [mm] H1 [mm] H2 [mm] W [mm] W1 [mm] W2 [mm] L [mm] L1 [mm] L2 [mm]
type Volume [l] Inlet/Outlet
[kg] [kg]
CRE 10-3 25 Rp 1" 1/2 75 95 667 682 80 392 252 140 752 594 127
CRE 10-5 25 Rp 1" 1/2 93 113 792 682 80 397 252 145 795 594 127
CRE 10-6 25 Rp 1" 1/2 105 125 822 682 80 397 252 145 795 594 127

22
Hydro Solo-E and Hydro Solo-E Optimum
4
Hydro Solo-E with CRE15 Electrical data

Hydro Solo-E
International range
Full-load Supply Voltage
p H Pump type Motor [kW]
current [A] [V]
[kPa] [m]
170 Hydro Solo-E CRE 15-2 3.00 6.20 - 5.00 3 x 380-480 V
1600 160 CRE 15 CRE 15-3 4.00 8.10 - 6.60 3 x 380-480 V
150 ISO 9906:2012 Grade 3B
1400 140 CRE 15-7 CRE 15-5 7.50 14.10 - 11.20 3 x 380-500 V
130 CRE 15-7 7.50 14.10 - 11.20 3 x 380-500 V
1200 120
110
1000
CRE 15-5 Southern European range
100
90 Full-load Supply Voltage
Pump type Motor [kW]
800 80 NPSH current [A] [V]
70 [m] CRE 15-2 3.00 6.20 - 5.00 3 x 380-480 V
CRE 15-3
600 60 6
CRE 15-3 4.00 8.10 - 6.60 3 x 380-480 V
50 5
CRE 15-2
400 40 4 CRE 15-5 7.50 14.10 - 11.20 3 x 380-415 V
30 3 CRE 15-7 7.50 14.10 - 11.20 3 x 380-415 V
200 20 2
NPSH
10 1
0 0 0 Dimensions and weights
0 4 8 12 16 20 24 Q [m³/h]

0 2 4 6 Q [l/s]
P2
[kW]

8
H

-7

H1
-5
6
DN1
DN2
4 -3

H2

TM058782
-2
2 L2 L1 W2 W1
L W
0
TM059024

0 4 8 12 16 20 24 Q [m³/h]

International range
Tank Net Gross
Pump Connection Connection
Volume weight weight H [mm] H1 [mm] H2 [mm] W [mm] W1 [mm] W2 [mm] L [mm] L1 [mm] L2 [mm]
type Inlet Outlet
[l] [kg] [kg]
CRE 15-2 18 DN 50 Rp 2" 86 89 754 505 90 404 259 140 882 681 150
CRE 15-3 18 DN 50 Rp 2" 98 101 799 505 90 404 259 140 882 681 150
CRE 15-5 12 DN 50 Rp 2" 111 135 976 506 90 404 259 115 918 681 150
CRE 15-7 12 DN 50 Rp 2" 115 139 1066 506 90 404 259 115 918 681 150

Southern European range


Tank Net Gross
Pump Connection Connection
Volume weight weight H [mm] H1 [mm] H2 [mm] W [mm] W1 [mm] W2 [mm] L [mm] L1 [mm] L2 [mm]
type Inlet Outlet
[l] [kg] [kg]
CRE 15-2 25 DN 50 Rp 2" 99 119 754 698 90 397 252 145 866 665 150
CRE 15-3 25 DN 50 Rp 2" 111 131 799 698 90 397 252 145 866 665 150
CRE 15-5 25 DN 50 Rp 2" 110 120 976 698 90 427 252 175 902 665 150
CRE 15-7 25 DN 50 Rp 2" 114 140 1066 698 90 427 252 175 902 665 150

23
4 Hydro Solo-E and Hydro Solo-E Optimum

Hydro Solo-E with CRE20 Electrical data


Hydro Solo-E

International range
Full-load Supply Voltage
p H Pump type Motor [kW]
current [A] [V]
[kPa] [m]
180 Hydro Solo-E CRE 20-2 4.00 8.10 - 6.60 3 x 380-480 V
170
1600 CRE 20 CRE 20-3 5.50 11.00 - 8.80 3 x 380-480 V
160 ISO 9906:2012 Grade 3B
150 CRE 20-7 CRE 20-4 7.50 14.10 - 11.20 3 x 380-500 V
1400 140
CRE 20-7 11.00 20.30 - 16.00 3 x 380-500 V
130
1200 120
110 Southern European range
1000 100 Full-load Supply Voltage
90 Pump type Motor [kW]
CRE 20-4 current [A] [V]
800 80
70 NPSH CRE 20-2 4.00 8.10 - 6.60 3 x 380-480 V
CRE 20-3
600 60 [m]
CRE 20-3 5.50 11.00 - 8.80 3 x 380-480 V
50 CRE 20-2 10
400 40 8 CRE 20-4 7.50 14.10 - 11.20 3 x 380-415 V
30 6 CRE 20-7 11.00 20.30 - 16.00 3 x 380-415 V
200 20 4
10 NPSH 2
0 0 0 Dimensions and weights
0 4 8 12 16 20 24 28 Q [m³/h]

0 2 4 6 8 Q [l/s]
P2
[kW]
12
-7
H

H1
10
8 DN1
-4 DN2
6
-3

H2

TM058782
4 -2
L2 L1 W2 W1
2
L W
0
TM059025

0 4 8 12 16 20 24 28 Q [m³/h]

International range
Tank Net Gross
Pump Connection Connection
Volume weight weight H [mm] H1 [mm] H2 [mm] W [mm] W1 [mm] W2 [mm] L [mm] L1 [mm] L2 [mm]
type Inlet Outlet
[l] [kg] [kg]
CRE 20-2 18 DN 50 Rp 2" 94 105 754 588 90 436 259 177 882 681 150
CRE 20-3 18 DN 50 Rp 2" 113 124 862 588 90 436 259 177 869 681 150
CRE 20-4 33 DN 50 Rp 2" 109 130 931 588 90 436 259 177 918 681 150
CRE 20-7 12 DN 50 Rp 2" 138 162 1160 506 90 436 257 155 989 681 150

Southern European range


Tank Net Gross
Pump Connection Connection
Volume weight weight H [mm] H1 [mm] H2 [mm] W [mm] W1 [mm] W2 [mm] L [mm] L1 [mm] L2 [mm]
type Inlet Outlet
[l] [kg] [kg]
CRE 20-2 25 DN 50 Rp 2" 110 130 754 698 90 397 252 145 866 665 150
CRE 20-3 25 DN 50 Rp 2" 128 148 862 698 90 402 252 150 866 665 150
CRE 20-4 25 DN 50 Rp 2" 110 120 931 698 90 427 252 175 902 665 150
CRE 20-7 25 DN 50 Rp 2" 137 147 1160 698 90 427 252 175 902 665 150

24
Hydro Solo-E and Hydro Solo-E Optimum
4
Hydro Solo-E with CRE32 Electrical data

Hydro Solo-E
International range
Full-load Supply Voltage
p H Pump type Motor [kW]
current [A] [V]
[kPa] [m]
1200 120 Hydro Solo-E CRE 32-2 7.50 14.10 - 11.20 3 x 380-500 V

110
CRE 32
CRE 32-4-2 ISO 9906:2012 Grade 3B Southern European range
1000 100
Full-load Supply Voltage
Pump type Motor [kW]
90 current [A] [V]
800 80 CRE 32-2 7.50 14.10 - 11.20 3 x 380-500 V
70
600 60 CRE 32-2
NPSH
[m]
Dimensions and weights
50 10
400 40 8
30 6
200 20 4

H
NPSH

H1
10 2
0 0 0 DN1
DN2
0 5 10 15 20 25 30 35 40 Q [m³/h]

H2

TM058782
0 2 4 6 8 10 12 Q [l/s]
L2 L1 W2 W1
P2
[kW] L W

12
-4-2
10
8
6 -2

4
2
0
TM059026

0 5 10 15 20 25 30 35 40 Q [m³/h]

International range
Net Gross
Pump Tank Connection
weight weight H [mm] H1 [mm] H2 [mm] W [mm] W1 [mm] W2 [mm] L [mm] L1 [mm] L2 [mm]
type Volume [l] Inlet/Outlet
[kg] [kg]
CRE 32-2 33 DN 65 118 129 960 603 105 449 272 177 932 695 160

Southern European range


Net Gross
Pump Tank Connection
weight weight H [mm] H1 [mm] H2 [mm] W [mm] W1 [mm] W2 [mm] L [mm] L1 [mm] L2 [mm]
type Volume [l] Inlet/Outlet
[kg] [kg]
CRE 32-2 33 DN 65 203 213 964 722 105 438 263 175 921 684 160

25
5 Hydro Solo-E and Hydro Solo-E Optimum
Accessories

5. Accessories
Fieldbus communication interfaces Float switch

GR-1015444

GR-1031152
The Grundfos fieldbus concept is the ideal solution for
The MS1 float switches are ON/OFF switches. Float
complete control of pumps and pump systems. The
switch MS 1 ACS is the ideal solution to control liquids
Communication Interface Module (CIM) enables data
with high hygienic requirements, for example in wells,
communication via open and interoperable networks.
bottling plants and drinking water reservoirs.

Protocol Name Product Number


Product Name Cable Length Product Number
LON CIM 100 96824797
1 float switch MS1 ACS 10 meters 99023672
Profibus DP CIM 150 96824793
1 float switch MS1 ACS 20 meters 99023669
Modbus RTU CIM 200 96824796
GSM/GRPS CIM 250 96824795
Dry-running protection
GRM CIM 270 96898815
Dry-running protection automatically stops the pump from
BACnet CIM 300 96893770
running without liquid. The dry-running protection unit is
PROFITNET IO installed on-site.
MODBUS TCB
CIM 500 98301408
BACnet IP
GRM IP Product Name Pressure [bar] Product Number
0.11 - 2 96421253
Grundfos GO Remote Hydro Solo-E * 0.22 - 4 96421254
0.5 - 8 96421255

* Only available as an accessory for Hydro Solo-E variants.


GR-1015578

Grundfos GO Remote offers intuitive, handheld


assistance and access to various Grundfos online tools to
help you monitor the product, change settings, collect
data and make reports

Grundfos GO Remote variant Product number


Grundfos MI 204 * 98424092
Grundfos MI 204 kit * 98612711
Grundfos MI 301 98046408

* This product is discontinued and can only be replaced with Grundfos MI 301.

26
Hydro Solo-E and Hydro Solo-E Optimum
6

Product numbers
6. Product numbers
Hydro Solo-E Optimum
Product number Pump type Voltage [V] Stainless steel Cast iron Product range
99432874 Hydro Solo-E CRIE 3-7 1 x 200-240 ● International
99432875 Hydro Solo-E CRIE 5-5 1 x 200-240 ● International
99432876 Hydro Solo-E CRIE 5-7 1 x 200-240 ● International
99432877 Hydro Solo-E CRIE 5-9 3 x 380-500 ● International
99432878 Hydro Solo-E CRIE 10-3 1 x 200-240 ● International
99432879 Hydro Solo-E CRIE 10-3 3 x 380-500 ● International
99432880 Hydro Solo-E CRIE 15-2 3 x 380-500 ● International
99432881 Hydro Solo-E CRIE 15-3 3 x 380-500 ● International

Hydro Solo-E
Product number Pump type Voltage [V] Stainless steel Cast iron Product range
98453506 Hydro Solo-E CRE 1-4 1 x 200-240 ● International
98769669 Hydro Solo-E CRE 1-6 1 x 200-240 ● International
98453546 Hydro Solo-E CRE 1-9 1 x 200-240 ● International
98453507 Hydro Solo-E CRE 1-13 1 x 200-240 ● International
98453508 Hydro Solo E CRE 1-17 1 x 200-240 ● International
98453542 Hydro Solo-E CRE 3-4 1 x 200-240 ● International
98453509 Hydro Solo-E CRE 3-5 1 x 200-240 ● International
98453510 Hydro Solo-E CRE 3-8 1 x 200-240 ● International
98453543 Hydro Solo-E CRE 3-11 1 x 200-240 ● International
98453544 Hydro Solo-E CRE 3-15 3 x 380-500 ● International
91048901 Hydro Solo-E CRE 3-15 3 x 380-500 ● International
98453511 Hydro Solo-E CRE 5-2 1 x 200-240 ● International
98453512 Hydro Solo-E CRE 5-5 1 x 200-240 ● International
98453513 Hydro Solo-E CRE 5-9 3 x 380-500 ● International
91048902 Hydro Solo-E CRE 5-12 3 x 380-500 ● International
91048903 Hydro Solo-E CRE 5-14 3 x 380-480 ● International
98453519 Hydro Solo-E CRE 10-1 1 x 200-240 ● International
98453520 Hydro Solo-E CRE 10-3 3 x 380-500 ● International
91048904 Hydro Solo-E CRE 10-5 3 x 380-500 ● International
91048905 Hydro Solo-E CRE 10-6 3 x 380-500 ● International
99150625 Hydro Solo-E CRE 15-2 3 x 380-480 ● International
99150626 Hydro Solo-E CRE 15-3 3 x 380-480 ● International
91048907 Hydro Solo-E CRE 15-5 3 x 380-500 ● International
91048908 Hydro Solo-E CRE 15-7 3 x 380-500 ● International
91048909 Hydro Solo-E CRE 20-2 3 x 380-480 ● International
91048910 Hydro Solo-E CRE 20-3 3 x 380-480 ● International
91048911 Hydro Solo-E CRE 20-4 3 x 380-500 ● International
99150631 Hydro Solo-E CRE 20-7 3 x 380-500 ● International
91048913 Hydro Solo-E CRE 32-2 3 x 380-500 ● International
91048917 Hydro Solo-E CRE 64-1 3 x 380-415 ● International
98488802 Hydro Solo-E CRE 1-6 1 x 200-240 ● Southern European
98478534 Hydro Solo-E CRE 1-9 1 x 200-240 ● Southern European
98478535 Hydro Solo-E CRE 1-13 1 x 200-240 ● Southern European
98478540 Hydro Solo-E CRE 3-8 1 x 200-240 ● Southern European
98478541 Hydro Solo-E CRE 3-11 1 x 200-240 ● Southern European
99172030 Hydro Solo-E CRE 3-15 3 x 380-500 ● Southern European
98478545 Hydro Solo-E CRE 5-5 1 x 200-240 ● Southern European
98478546 Hydro Solo-E CRE 5-9 3 x 380-415 ● Southern European
99172032 Hydro Solo-E CRE 5-12 3 x 380-415 ● Southern European

27
6 Hydro Solo-E and Hydro Solo-E Optimum

Product number Pump type Voltage [V] Stainless steel Cast iron Product range
Product numbers

99172044 Hydro Solo-E CRE 5-14 3 x 380-415 ● Southern European


98478550 Hydro Solo-E CRE 10-3 3 x 380-480 ● Southern European
99172045 Hydro Solo-E CRE 10-5 3 x 380-480 ● Southern European
99172046 Hydro Solo-E CRE 10-6 3 x 380-480 ● Southern European
99172049 Hydro Solo-E CRE 15-2 3 x 380-480 ● Southern European
99172051 Hydro Solo-E CRE 15-3 3 x 380-480 ● Southern European
99172054 Hydro Solo-E CRE 15-5 3 x 380-415 ● Southern European
99172055 Hydro Solo-E CRE 15-7 3 x 380-415 ● Southern European
99172058 Hydro Solo-E CRE 20-2 3 x 380-480 ● Southern European
99172059 Hydro Solo-E CRE 20-3 3 x 380-480 ● Southern European
99172060 Hydro Solo-E CRE 20-4 3 x 380-415 ● Southern European
99172061 Hydro Solo-E CRE 20-7 3 x 380-415 ● Southern European
99172063 Hydro Solo-E CRE 32-2 3 x 380-500 ● Southern European
99172066 Hydro Solo-E CRE 64-1 3 x 380-500 ● Southern European
99507461 Hydro Solo-E CRIE 3-4 1 x 200-240 ● Netherlands
99617989 Hydro Solo-E CRIE 3-5 1 x 200-240 ● Netherlands
99204952 Hydro Solo-E CRIE 3-8 1 x 200-240 ● Netherlands
99204953 Hydro Solo-E CRIE 5-5 1 x 200-240 ● Netherlands
99204954 Hydro Solo-E CRIE 5-9 3 x 380-500 ● Netherlands
99204955 Hydro Solo-E CRIE 10-3 3 x 380-500 ● Netherlands
99204956 Hydro Solo-E CRIE 10-5 3 x 380-500 ● Netherlands
99204957 Hydro Solo-E CRIE 15-3 3 x 380-500 ● Netherlands

28
Argentina Denmark Korea Singapore

Grundfos companies
Bombas GRUNDFOS de Argentina S.A. GRUNDFOS DK A/S GRUNDFOS Pumps Korea Ltd. GRUNDFOS (Singapore) Pte. Ltd.
Ruta Panamericana km. 37.500industin Martin Bachs Vej 3 6th Floor, Aju Building 679-5 25 Jalan Tukang
1619 - Garín Pcia. de B.A. DK-8850 Bjerringbro Yeoksam-dong, Kangnam-ku, 135-916 Singapore 619264
Tel.: +54-3327 414 444 Tel.: +45-87 50 50 50 Seoul, Korea Tel.: +65-6681 9688
Fax: +54-3327 45 3190 Fax: +45-87 50 51 51 Tel.: +82-2-5317 600 Faxax: +65-6681 9689
E-mail: info_GDK@grundfos.com Fax: +82-2-5633 725
Australia www.grundfos.com/DK Slovakia
GRUNDFOS Pumps Pty. Ltd. Latvia GRUNDFOS s.r.o.
P.O. Box 2040 Estonia SIA GRUNDFOS Pumps Latvia Prievozská 4D 821 09 BRATISLAVA
Regency Park GRUNDFOS Pumps Eesti OÜ Deglava biznesa centrs Tel.: +421 2 5020 1426
South Australia 5942 Peterburi tee 92G Augusta Deglava ielā 60 sk.grundfos.com
Tel.: +61-8-8461-4611 11415 Tallinn LV-1035, Rīga,
Fax: +61-8-8340-0155 Tel.: + 372 606 1690 Tel.: + 371 714 9640, 7 149 641 Slovenia
Fax: + 372 606 1691 Fax: + 371 914 9646 GRUNDFOS LJUBLJANA, d.o.o.
Austria Leskoškova 9e, 1122 Ljubljana
GRUNDFOS Pumpen Vertrieb Ges.m.b.H. Finland Lithuania Tel.: +386 (0) 1 568 06 10
Grundfosstraße 2 OY GRUNDFOS Pumput AB GRUNDFOS Pumps UAB Fax: +386 (0)1 568 06 19
A-5082 Grödig/Salzburg Trukkikuja 1 Smolensko g. 6 E-mail: tehnika-si@grundfos.com
Tel.: +43-6246-883-0 FI-01360 Vantaa LT-03201 Vilnius
Fax: +43-6246-883-30 Tel.: +358-(0) 207 889 500 Tel.: + 370 52 395 430 South Africa
Fax: + 370 52 395 431 GRUNDFOS (PTY) LTD
Belgium France 16 Lascelles Drive, Meadowbrook Estate
N.V. GRUNDFOS Bellux S.A. Pompes GRUNDFOS Distribution S.A. Malaysia 1609 Germiston, Johannesburg
Boomsesteenweg 81-83 Parc d’Activités de Chesnes GRUNDFOS Pumps Sdn. Bhd. Tel.: (+27) 10 248 6000
B-2630 Aartselaar 57, rue de Malacombe 7 Jalan Peguam U1/25 Fax: (+27) 10 248 6002
Tel.: +32-3-870 7300 F-38290 St. Quentin Fallavier (Lyon) Glenmarie industrial Park E-mail: lgradidge@grundfos.com
Fax: +32-3-870 7301 Tel.: +33-4 74 82 15 15 40150 Shah Alam, Selangor
Fax: +33-4 74 94 10 51 Tel.: +60-3-5569 2922 Spain
Belarus Fax: +60-3-5569 2866 Bombas GRUNDFOS España S.A.
Представительство ГРУНДФОС в Germany Camino de la Fuentecilla, s/n
Минске GRUNDFOS GMBH Mexico E-28110 Algete (Madrid)
220125, Минск Schlüterstr. 33 Bombas GRUNDFOS de México Tel.: +34-91-848 8800
ул. Шафарнянская, 11, оф. 56, БЦ 40699 Erkrath S.A. de C.V. Fax: +34-91-628 0465
«Порт» Tel.: +49-(0) 211 929 69-0 Boulevard TLC No. 15
Тел.: +375 17 397 397 3 Fax: +49-(0) 211 929 69-3799 Parque industrial Stiva Aeropuerto Sweden
+375 17 397 397 4 E-mail: infoservice@grundfos.de Apodaca, N.L. 66600 GRUNDFOS AB
Факс: +375 17 397 397 1 Service in Deutschland: Tel.: +52-81-8144 4000 Box 333 (Lunnagårdsgatan 6)
E-mail: minsk@grundfos.com kundendienst@grundfos.de Fax: +52-81-8144 4010 431 24 Mölndal
Tel.: +46 31 332 23 000
Bosnia and Herzegovina Greece Netherlands Fax: +46 31 331 94 60
GRUNDFOS Sarajevo GRUNDFOS Hellas A.E.B.E. GRUNDFOS Netherlands
Zmaja od Bosne 7-7A 20th km. Athinon-Markopoulou Av. Veluwezoom 35 Switzerland
BiH-71000 Sarajevo P.O. Box 71 1326 AE Almere GRUNDFOS Pumpen AG
Tel.: +387 33 592 480 GR-19002 Peania Postbus 22015 Bruggacherstrasse 10
Fax: +387 33 590 465 Tel.: +0030-210-66 83 400 1302 CA ALMERE CH-8117 Fällanden/ZH
www.ba.grundfos.com Fax: +0030-210-66 46 273 Tel.: +31-88-478 6336 Tel.: +41-44-806 8111
E-mail: grundfos@bih.net.ba Fax: +31-88-478 6332 Fax: +41-44-806 8115
Hong Kong E-mail: info_gnl@grundfos.com
Brazil GRUNDFOS Pumps (Hong Kong) Ltd. Taiwan
BOMBAS GRUNDFOS DO BRASIL Unit 1, Ground floor, Siu Wai industrial New Zealand GRUNDFOS Pumps (Taiwan) Ltd.
Av. Humberto de Alencar Castelo Branco, Centre GRUNDFOS Pumps NZ Ltd. 7 Floor, 219 Min-Chuan Road
630 29-33 Wing Hong Street & 68 King Lam 17 Beatrice Tinsley Crescent Taichung, Taiwan, R.O.C.
CEP 09850 - 300 Street, Cheung Sha Wan North Harbour Industrial Estate Tel.: +886-4-2305 0868
São Bernardo do Campo - SP Kowloon Albany, Auckland Fax: +886-4-2305 0878
Tel.: +55-11 4393 5533 Tel.: +852-27861706 / 27861741 Tel.: +64-9-415 3240
Thailand
Fax: +55-11 4343 5015 Fax: +852-27858664 Fax: +64-9-415 3250
GRUNDFOS (Thailand) Ltd.
Bulgaria Hungary Norway 92 Chaloem Phrakiat Rama 9 Road
Grundfos Bulgaria EOOD GRUNDFOS Hungária Kft. GRUNDFOS Pumper A/S Dokmai, Pravej, Bangkok 10250
Slatina District Tópark u. 8 Strømsveien 344 Tel.: +66-2-725 8999
Iztochna Tangenta street no. 100 H-2045 Törökbálint Postboks 235, Leirdal Fax: +66-2-725 8998
BG - 1592 Sofia Tel.: +36-23 511 110 N-1011 Oslo
Turkey
Tel.: +359 2 49 22 200 Fax: +36-23 511 111 Tel.: +47-22 90 47 00
GRUNDFOS POMPA San. ve Tic. Ltd. Sti.
Fax: +359 2 49 22 201 Fax: +47-22 32 21 50
India Gebze Organize Sanayi Bölgesi
E-mail: bulgaria@grundfos.bg
GRUNDFOS Pumps india Private Limited Poland Ihsan dede Caddesi
Canada 118 Old Mahabalipuram Road GRUNDFOS Pompy Sp. z o.o. 2. yol 200. Sokak No. 204
GRUNDFOS Canada inc. Thoraipakkam ul. Klonowa 23 41490 Gebze/ Kocaeli
2941 Brighton Road Chennai 600 097 Baranowo k. Poznania Tel.: +90 - 262-679 7979
Oakville, Ontario Tel.: +91-44 2496 6800 PL-62-081 Przeźmierowo Fax: +90 - 262-679 7905
L6H 6C9 Tel.: (+48-61) 650 13 00 E-mail: satis@grundfos.com
Tel.: +1-905 829 9533 Indonesia Fax: (+48-61) 650 13 50
PT GRUNDFOS Pompa Ukraine
Fax: +1-905 829 9512
Graha intirub Lt. 2 & 3 Portugal Бізнес Центр Європа
China Jln. Cililitan Besar No.454. Makasar, Bombas GRUNDFOS Portugal, S.A. Столичне шосе, 103
GRUNDFOS Pumps (Shanghai) Co. Ltd. Jakarta Timur Rua Calvet de Magalhães, 241 м. Київ, 03131, Україна
10F The Hub, No. 33 Suhong Road ID-Jakarta 13650 Apartado 1079 Tel.: (+38 044) 237 04 00
Minhang District Tel.: +62 21-469-51900 P-2770-153 Paço de Arcos Fax: (+38 044) 237 04 01
Shanghai 201106 PRC Fax: +62 21-460 6910 / 460 6901 Tel.: +351-21-440 76 00 E-mail: ukraine@grundfos.com
Tel.: +86 21 612 252 22 Fax: +351-21-440 76 90
Ireland United Arab Emirates
Fax: +86 21 612 253 33
GRUNDFOS (Ireland) Ltd. Romania GRUNDFOS Gulf Distribution
Columbia Unit A, Merrywell Business Park GRUNDFOS Pompe România SRL P.O. Box 16768
GRUNDFOS Colombia S.A.S. Ballymount Road Lower S-PARK BUSINESS CENTER, Clădirea Jebel Ali Free Zone, Dubai
Km 1.5 vía Siberia-Cota Conj. Potrero Dublin 12 A2, etaj 2 Tel.: +971 4 8815 166
Chico, Tel.: +353-1-4089 800 Str. Tipografilor, Nr. 11-15, Sector 1, Cod Fax: +971 4 8815 136
Parque Empresarial Arcos de Cota Bod. Fax: +353-1-4089 830 013714
United Kingdom
1A. Bucuresti, Romania
Italy GRUNDFOS Pumps Ltd.
Cota, Cundinamarca Tel.: 004 021 2004 100
GRUNDFOS Pompe Italia S.r.l. Grovebury Road
Tel.: +57(1)-2913444 E-mail: romania@grundfos.ro
Via Gran Sasso 4 Leighton Buzzard/Beds. LU7 4TL
Fax: +57(1)-8764586
I-20060 Truccazzano (Milano) Russia Tel.: +44-1525-850000
Croatia Tel.: +39-02-95838112 ООО Грундфос Россия Fax: +44-1525-850011
GRUNDFOS CROATIA d.o.o. Fax: +39-02-95309290 / 95838461 ул. Школьная, 39-41
U.S.A.
Buzinski prilaz 38, Buzin Москва, RU-109544, Russia
Japan GRUNDFOS Water Utility Headquarters
HR-10010 Zagreb Тел. (+7) 495 564-88-00 (495) 737-30-00
GRUNDFOS Pumps K.K. 856 Koomey Road
Tel.: +385 1 6595 400 Факс (+7) 495 564 8811
1-2-3, Shin-Miyakoda, Kita-ku Brookshire, Texas 77423 USA
Fax: +385 1 6595 499 E-mail grundfos.moscow@grundfos.com
www.hr.grundfos.com Hamamatsu
Uzbekistan
431-2103 Japan Serbia
Grundfos Tashkent, Uzbekistan
Czech Republic Tel.: +81 53 428 4760 Grundfos Srbija d.o.o.
The Representative Office of Grundfos
GRUNDFOS Sales Czechia and Slovakia Fax: +81 53 428 5005 Omladinskih brigada 90b
Kazakhstan in Uzbekistan
s.r.o. 11070 Novi Beograd
38a, Oybek street, Tashkent
Čajkovského 21 Tel.: +381 11 2258 740
Tel.: (+998) 71 150 3290 / 71 150 3291
779 00 Olomouc Fax: +381 11 2281 769
Fax: (+998) 71 150 3292
Tel.: +420-585-716 111 www.rs.grundfos.com
Revision Info
Grundfos companies

Last revised on 09-09-2020


V7140010
ECM: 1315222
06.2021
Trademarks displayed in this material, including but not limited to Grundfos, the Grundfos logo and “be think innovate” are registered trademarks owned by The Grundfos Group. All rights reserved. © 2021 Grundfos Holding A/S, all rights reserved.