Professional Documents
Culture Documents
Escalator Safety Procedure - Pictorial
Escalator Safety Procedure - Pictorial
1. Stop the escalator and 2. Using key switch to move the 3. With the escalator RUNNING,
Placed barricade on both escalator to verify both UP and DOWN. Open the platform using
landing and tie the barricade approved lifting bar.
4. Platform plate switch verified if 5. Press ESTOP on the 6. Verify controller Estop is
escalator stop moving controller and CLOSE the functioning by using key switch to
escalator platform move the escalator. Now you
have verify the function of two
* Repeat the process at lower landing before you enter lower landing area independent safeties before enter
Escalator Safety Procedure
1.Conduct JHA before entering 2. Verify electrical glove. Wear electrical 3.Switch off the Main
escalator pit glove and verify multimeter at known source Supply and do LOTO.
*Do not switch off any
other main supply
switches (in series)
3 phase
1. Connect the pendant control to the 2. Temporary bypass trap 3.Release controller Estop. Then
controller on INSP mode. door switch Use keyswitch to try move
*for certain SIGMA models escalator. If escalator cannot
move, then INSP mode is verified
4. Then Verify both UP and 5.Engage pendant ESTOP and verify 6.Press ESTOP on controller. *
DOWN on pendant ESTOP functioning by trying to move
escalator
*Always engage 2 independent safeties (Controller Estop and Pendant Estop) prior to entering escalator pit to work
Escalator Safety Procedure- iv) Mechanical Blocking prior to working in truss
Types of mechanical
blocking depends on
escalator model. Mechanics
are required to perform at
least 2 mechanical blocking.
Method 2- apply brake and check step Method 3- synthetic slings (padded)
(maximum slide of 1.5 step length). around step axle in both directions
*To tighten or loosen the brake