Simulation of a Demethanizer unit (Expander Plant)
The demethanizer in an expander plant removes methane from a gas stream whose: Flowrate : 8 m3/s Temperature : 120oF (Fahrenheit) (0F = (0C 1,8) + 32) Pressure : 602,7 psia (psia = pound per square inch absolute) (1 psi = 0,06896 bar; 602,7 psia = 588,2 psig (gauge)) 1 atm = 1,01325 bar Composition of the inlet gas
Component % mol Component % mol
N2 7,91 n-C4H10 2,44
CH4 73,05 i-C5H12 0,69
C2H6 7,68 n-C5H12 0,82
C3H8 5,69 C6H14 0,42
i-C4H10 0,99 C7H16 0,31
PFD of Expander Plant 100F = Hot Inlet - Cold Outlet Temperature Approach (HICO) Specification: maintain a C1/C2 molar ratio of 0.015 in the column liquid product The expander efficiency is: EX1 = 80% and the compressor efficiency is C1 = 75%. Determine: 1. Actual work of compressor C1? 2. Composition, flowrate, temperature and pressure of gas and liquid products?