You are on page 1of 4
Screening and clinical OAE Echolab screener - TE OAE Echolab clinical - TE OAE, DP OAE, S OAE Optional Upgrade: Screening ABR / AABR Thermal Printer User programmable protocols PC connectivity through USB labatiiK/ ECHOLAB - Otoacoustic emissions system TEOAE - DPOAE - ABR - AABR Full Featured Clinical OAE in the Palm of your hand * Innovative, fast, reliable * Ideal handheld unit for easy neonatal screening as well as clinical testing; TEOAE, DPOAE, Suppression Test (with optional noise insert). * Software programs allow EchoLab to be used in clinical as well as research applications * Screening AABR testing using the optional ABR pre-amplifier Screening, simple as the smile of a child * Perfect answer to the needs of neonatal screening. « Reliable results with the automatic control of the probe and the calibration, combined with the realtime measurement of the environmental noise. * Easy and fast operation « Storage of 250 tests « Faster data transfer through USB Light and Perfect. * Exceptional light weight of the probe simplifies neonatal testing * Proper cleaning by removing probe end from the probe * Unique design of different sizes of eartips allow easy insertion in the ear canal with effective external noise reduction The ABR / AABR Test * With the optional ABR pre-amplifier; it is possible to conduct the ABR and AABR tests with click stimulation generated by the same OAE probe * Impedance check prior to ABR testing * Realtime ABR traces on LCD display « Automatic interpretation of "PASS” or “REFER” in AABR iLabat Au‘ jologic ). the mos! gical software: % evolved audiolos All the information on the display From the simple final Pass/Refer to the complete trace Of the tests TEOAE, DPOAE, SPONTANEOUS and ABR. a b> TEOAE DPOAE Automatic Complete DP-gram Pass/Refor results with response and note ag TEOAE DPOAE Aequred response Hstogram oF Fira and DP with Pass/Refer EEN eel Fee Hho. oe et) TEOAE PROTOCOLS Response spectrum User selected Que amma cc ms cn AABR TEST COUNT ‘Acta! ABR trace According to type, and possibilty to view them ‘onthe deploy ECHOLAB OAE Technical Data Inbots Echols otoacaustic eras aysiem GENERAL CHARACTERISTICS OAE for screening and clinical testing with AABR option Mand held unt with alphanumeric keyboard TEOAE DPOAE one sampling STEOAE - Transient Evoked OAE 25600 | 20480 | 25600 | 40000 1 PORE - Distortion Product OAE ‘TEOAE - Linear and non-linear stimuli pawmplng, | siz | oss | 1024 | 4000 ‘Frequency Range 1000-5000 He { Frequency Resolution 50 Hz + Microphone: 15 dB SPL a 1000 Hz 20 dB SPL a 2000 Hz { Freaueney Accuracy £0,04% { Accuracy! 2-48 SPL microphone and in stu sound level + Stimulus Level 0-90 08 SPL {Automatic in atu calibration 1 Level accuracy 42 4B SPL ACCESSORIES OAE + Dynamic Range 90 dB SPL Sone prove + Ear tips for adults and neonates DPORE - distortion product z Aa ‘Frequency Range 250-10,000 Hz 7 pen eer shah Hatin g *Fpetuaney Resclution 5 10,23 program fate acces = + Freavenoy Accuracy 0.61% | ne 2 ‘+ Stimulus intensity 0-90 4B HL '* Carrying case z '» Stimulus level accuracy #2 dB SPL. «Inst jon manual (Soft Cor é = Dynamic Range 90.45 SPL mee Siok Conn) 3 INTERNAL MEMORY AND DATA TRANSFER i Leo w2s0 tet a + Graphic esplay 240x160 pliel high definition + USB connection to PC with visualization of: input signal, OAE trace, POWER SUPPLY 2 Spectrum, OP gram, test resus PASS/REFER Rechergeable Nh battery with duration per chargers hours Vuetzation oF ABR trace ‘Automatic low battery warning = Uist cterier 3 AABR Technical Data 3 TYeair abe crinn >10048 Brmenegans ] Weexairr : weirs ‘100 fieeoein Hz cm 9.5,Gw)23 (h) x 5.5 (d) - 3.7" (w) x 9% (h) x 2.2" (d) 7 + Analysis te: 10, 12.0 15 ms programmable ete 95) acu ater i + Stimulus rate: up to 18/sec ELECTRODES IMPEDANCE CHECK : { Number of averages: 1000 or programmable + biferentil single electrode control 3 {Automat artifact contrat GRAPHIC VISUALIZATION 5 aa ‘easter dg seston anal rout Pssttr 4 sdk postive - negative alternate Paneer i arta 90 48 SP STANDARD ABR ACCESSORIES g GENERAL Information (BR amplifier with cable z GENERAL IH S1opton of padre reeled single use electrodes “Temperature shppingInventry: 20°C to +S0%C,-4* to +1229 ; Temperature worxing +15 0 *350C, +60 to + 95°F é Humid: 30% to 90% : STANDARDS. ‘SECURITY AUDIOMETRICS UNITS EN 60645-1 (1994), EN 60645-3 (1995); EN 60603-1 (1990) Class II - Type B ANSI $3.6 (1996); EN ISO 389 (1995) EMC - EN 60801-1-1 (2001) - EMC; EN6O601-1-2 (1993) ‘Specifications and fetures canbe changed without notice Labatt Asia Pvt Lid labart}) LN CE (A Subsidiary of a ee Srl, Italy) Plot No. 24/4, Phase 2, Industrial Area Chandigarh 160 002 (U.T.) India Via Raffaello Sanzio, 3 Tel.: +91 172 2654300, Fax: +91 172 2654200 31021 Mogliano Veneto (TV), Italy info@labatasia.com www.labatasia.com Website: www.labat.it, E-Mail : info@labat.it

You might also like