Screening and clinical OAE
Echolab screener - TE OAE
Echolab clinical -
TE OAE, DP OAE, S OAE
Optional Upgrade: Screening ABR / AABR
Thermal Printer
User programmable protocols
PC connectivity through USB
labatiiK/ECHOLAB - Otoacoustic emissions system
TEOAE - DPOAE - ABR - AABR
Full Featured Clinical OAE in the Palm of your hand
* Innovative, fast, reliable
* Ideal handheld unit for easy neonatal
screening as well as clinical testing;
TEOAE, DPOAE, Suppression Test (with
optional noise insert).
* Software programs allow EchoLab to be
used in clinical as well as research
applications
* Screening AABR testing using the
optional ABR pre-amplifier
Screening, simple as the smile of a child
* Perfect answer to the needs of neonatal
screening.
« Reliable results with the automatic control
of the probe and the calibration, combined
with the realtime measurement of the
environmental noise.
* Easy and fast operation
« Storage of 250 tests
« Faster data transfer through USB
Light and Perfect.
* Exceptional light weight of the probe
simplifies neonatal testing
* Proper cleaning by removing probe
end from the probe
* Unique design of different sizes of
eartips allow easy insertion in the
ear canal with effective external
noise reductionThe ABR / AABR Test
* With the optional ABR pre-amplifier; it is
possible to conduct the ABR and AABR
tests with click stimulation generated by
the same OAE probe
* Impedance check prior to ABR testing
* Realtime ABR traces on LCD display
« Automatic interpretation of "PASS” or
“REFER” in AABR
iLabat Au‘ jologic ).
the mos!
gical software:
% evolved
audiolos
All the information
on the display
From the simple final Pass/Refer to the complete trace
Of the tests TEOAE, DPOAE, SPONTANEOUS and ABR.
a b>
TEOAE DPOAE
Automatic Complete DP-gram
Pass/Refor results
with response and note
ag
TEOAE DPOAE
Aequred response Hstogram oF Fira
and DP with Pass/Refer
EEN eel Fee
Hho.
oe et)
TEOAE PROTOCOLS
Response spectrum User selected
Que amma cc ms cn
AABR TEST COUNT
‘Acta! ABR trace According to type,
and possibilty to view them
‘onthe deployECHOLAB OAE Technical Data
Inbots Echols otoacaustic eras aysiem GENERAL CHARACTERISTICS OAE
for screening and clinical testing with AABR option
Mand held unt with alphanumeric keyboard TEOAE DPOAE
one sampling
STEOAE - Transient Evoked OAE 25600 | 20480 | 25600 | 40000
1 PORE - Distortion Product OAE
‘TEOAE - Linear and non-linear stimuli pawmplng, | siz | oss | 1024 | 4000
‘Frequency Range 1000-5000 He
{ Frequency Resolution 50 Hz + Microphone: 15 dB SPL a 1000 Hz 20 dB SPL a 2000 Hz
{ Freaueney Accuracy £0,04% { Accuracy! 2-48 SPL microphone and in stu sound level
+ Stimulus Level 0-90 08 SPL {Automatic in atu calibration
1 Level accuracy 42 4B SPL ACCESSORIES OAE
+ Dynamic Range 90 dB SPL Sone prove
+ Ear tips for adults and neonates
DPORE - distortion product z Aa
‘Frequency Range 250-10,000 Hz 7 pen eer shah Hatin g
*Fpetuaney Resclution 5 10,23 program fate acces =
+ Freavenoy Accuracy 0.61% | ne 2
‘+ Stimulus intensity 0-90 4B HL '* Carrying case z
'» Stimulus level accuracy #2 dB SPL. «Inst jon manual (Soft Cor é
= Dynamic Range 90.45 SPL mee Siok Conn) 3
INTERNAL MEMORY AND DATA TRANSFER i
Leo w2s0 tet a
+ Graphic esplay 240x160 pliel high definition + USB connection to PC
with visualization of: input signal, OAE trace, POWER SUPPLY 2
Spectrum, OP gram, test resus PASS/REFER Rechergeable Nh battery with duration per chargers hours
Vuetzation oF ABR trace ‘Automatic low battery warning
= Uist cterier 3
AABR Technical Data 3
TYeair abe crinn >10048 Brmenegans ] Weexairr :
weirs ‘100 fieeoein Hz cm 9.5,Gw)23 (h) x 5.5 (d) - 3.7" (w) x 9% (h) x 2.2" (d) 7
+ Analysis te: 10, 12.0 15 ms programmable ete 95) acu ater i
+ Stimulus rate: up to 18/sec ELECTRODES IMPEDANCE CHECK :
{ Number of averages: 1000 or programmable + biferentil single electrode control 3
{Automat artifact contrat GRAPHIC VISUALIZATION 5
aa ‘easter dg seston anal rout Pssttr 4
sdk postive - negative alternate Paneer i
arta 90 48 SP STANDARD ABR ACCESSORIES g
GENERAL Information (BR amplifier with cable z
GENERAL IH S1opton of padre reeled single use electrodes
“Temperature shppingInventry: 20°C to +S0%C,-4* to +1229 ;
Temperature worxing +15 0 *350C, +60 to + 95°F é
Humid: 30% to 90% :
STANDARDS. ‘SECURITY
AUDIOMETRICS UNITS
EN 60645-1 (1994), EN 60645-3 (1995); EN 60603-1 (1990) Class II - Type B
ANSI $3.6 (1996); EN ISO 389 (1995) EMC - EN 60801-1-1 (2001) - EMC; EN6O601-1-2 (1993)
‘Specifications and fetures canbe changed without notice Labatt Asia Pvt Lid
labart}) LN CE (A Subsidiary of a ee Srl, Italy)
Plot No. 24/4, Phase 2, Industrial Area
Chandigarh 160 002 (U.T.) India
Via Raffaello Sanzio, 3 Tel.: +91 172 2654300, Fax: +91 172 2654200
31021 Mogliano Veneto (TV), Italy info@labatasia.com www.labatasia.com
Website: www.labat.it, E-Mail : info@labat.it