If there are holes in the tension flange at the section
under consideration, the tension flange shall also satisfy
the requirement specified in Article 6.10.1.8.
Load-resisting bolted connections either in or to
flexural members shall be proportioned to prevent slip under the factored loads at each critical construction stage. The provisions of Article 6.13.2.8 shall apply for investigation of connection slip.
6.10.3.2—Flexure
6.10.3.2.1—Discretely Braced Flanges in
Compression
For critical stages of construction, each of the
following requirements shall be satisfied. For sections with slender webs, Eq. 6.10.3.2.1-1 shall not be checked when fe is equal to zero. For sections with compact or noncompact webs, Eq. 6.10.3.2.1-3 shall not be checked.
Sut Fp S90 RiF veo (6.10.3.2.1-1)
. 1
Si toh <6,F,.5 (6.10.3.2.1-2)
and
Sou £9 Fony (6.10.3.2.1-3)
where:
dy = resistance factor for flexure specified in
Article 6.5.4.2. foun = flange stress calculated without consideration of
flange lateral bending determined as specified in
Article 6.10.1.6 (ksi)
fe = flange lateral bending stress determined as
specified in Article 6.10.1.6 (ksi)
Few= nominal bend-buckling resistance for webs
specified in Article 6.10.1.9 (ksi)
Fre = nominal flexural resistance of the flange (ksi). Fre
shall be determined as_ specified in
Article 6.10.8.2. For sections in straight I-girder bridges with compact or noncompact webs, the lateral torsional buckling resistance may be taken as M,- determined as specified in Article A6.3.3 divided by Syc. In computing F;,. for constructibility, the web load-shedding factor, Rp, shall be taken as 1.0.
Myc = yield moment with respect to the compression
flange determined as specified in Article D6.2 (kip-in.)
R, = hybrid factor specified in Article 6.10.1.10.1. For
hybrid sections in which fj, does not exceed the
specified minimum yield strength of the web, the hybrid factor shall be taken equal to 1.0.