You are on page 1of 4
WIN Equipments che =e EVAPORATIVE COOLING TOWER TEFC IPSS Extended Shaft CT Motors Dynamic Balanced Axial Flow Fan Honey Comb Design PVC Fills ‘Automatic Rotary Sprinkler, Spray Nozzles Anti Corrosive Fasteners HDG MS Structure UV Resin — FRP Casing. capacity 10 to 300 TR Inlet Water Pressure : 2to3barg Inlet Water Temperature: 40 to 100°C Outlet Water Temperature : WBT+4 deg [Working Principle A cooling tower is a heat rejection device, which extracts waste heat from the Application to the atmosphere by using the fan and motor, The type of heat rejection in a cooling tower is termed “evaporative”. To Maintain the ‘Temperature Limit, We Use Cooling Towers to get high performance from the Machine. It should be kept Temperature Limits. Hot water flows to the main sewer of the water distribution system. Then, the water is distributed through a pipe system to spray nozzles. Nozzles cause the dispersion of the water onto the wet deck surface, thus creating water film of large contact surface. The water coming off the lower edges of the wet deck surface falls down in the form of droplets to the cooled water tank, from whereitis pumped back o the cooled equipment. [iiroduct Features “= Made of Gel coated fibre glass reinforced polyester (FRP) and resins. "= Compact & Light weight resulting in 2sy instalation 1 Rig Poly Vinyl chloride (PVC) «= Honey comb design with very large contact surface area ‘= PVC Fils 600 x 300 x 150 mm, Color Block 4 Fils Flute height 12mm to 19mm & sheet thick 0.2 t0.0.25 mm ‘+ Reduces Carry over loss of water ‘= Made of rigid PUC (Applicable of Square type cooling towers) “= rift Size 600 x 600 x 130 mm «= Easy clean no damage ‘= Itcan with stand Temp more than 90 deg C 1 Rigid individual no bonded Elchematic Diagram ‘= Jet cecoll force to rotate and distribute the water & uniform water flow. «= Automatic Rotary system made of Nylon & Aluminum ‘= Minimizes the drift loss of water ‘= Applicable Round & Square type cooling towers 1 Sa cae indction,TEF, P55, Flanged with extended shaft 1 Powersupply of &15v/3ph/ Soke & "= Using standard make Hindustan/Stark motor only. 1 Distribute water eveny tough awie sora ancle ga Dynamic balanced energy efficient axial type Low running cost * Lowest nose level wes + Made of Aluminum alloy & Nyon 65 \ a rexsonomce emai Ont Glechnical specifications Round Cooling Tower Data Sheets bia of] in/out Shipping [Operating capacity | Modelvarience | Motor Overall Dimensions Model Fan | Size weight | weight te ram] tw | | He [Rom] mm] ne Detinmm [ke | ke werorwat| 10] 6[ v | v |v | 05 [saao] aso |r" sax] 930x160 | 20 | 280 weroaa] 20] 12] v |v |v [1 [960] 750] 2°72" | 1380x1690 | 100 | 450 weroson| 30] a8] v |v |v | 2 [960] 750] 3°73" | 660x860 | 175 | 540 weroaat] 40] 24¢[ v |v |v [1 [960] eso] ara | 1780x1950 | 205 | 700 weroson] so] 30[ v |v |v | 2 [960] 900] 37 1990x2120 | 260 | 760 werosont| eo | 36[ v |v |v | 3 [960]iteo] a7" | 1920x2720 | 230 | 00 weroson| 80] aa) v |v |v | 3 | 960]st60] arya" | 2150x2670 | 375 | 590 wersooat| 100 [eof v |v |v | s [560] saoo[ S75" | 2595x3050 | eis | 1850 weraasat] as] 75| v |v |v | 5 | 960]sa00] s/s" | 2950x3250 | 805 | 2300 werasont| iso [ sof v |v |v | s | 960]s600] 575" | 3000x3950 | 005 | 2650 wer2o0at| 200 | 120] v |v |v | 75 710]s800] 676" | 3300x4230 | 1110 | 3050 wersoort| 300 [180] v |v |v [225] 600] 2ao0[ e7a* | aasox3000 | 1950 | 4050 ‘Square Cooling Tower Data Sheets ota of] in/out Shipping [Operating Capacity | Modelvarience | Motor Overall Dimensions Model Fan | size weight | weight te frat] t [He | we [Rom[ mm] ne | txoxHinmm | ke | ke weroros| 10] 6 | v | v | v | 05 [r440] 450] 2°/2" | 825x825%1500 | a5 | 210 wero2os.| 20] 12 | v |v |v | 05 [1400 450 825x825x1900 | 90 | 225 weroaos] 30] a8 | v | v |v | a [960] 750 | 2"/2* |1000%1000%2100] 260 | 750 weroast | 40] 24 | v |v |v | 4 [960] 800 ]2x"/2%"]3170%1170x2600] 320 | 850 werosos.] 60] 36 | v |v |v | 2 | 960[ 1160 1400 1400x2400| 350 | 910 werso0st | 100 [60 |v |v |v |S [260] s400 1750%x1750x 2800 525 | 1550 werasos. | 150] 90 | v | v | v | 75 | 960 | 1400 }2a00x 2400x3100 700 | 2100 werzo0st | 200 [20 | v |v |v [75 | 710 [1800 2400 %x2400%3300| 775 | 2250 wersos.| 250] 180 | v | v | v | 10 | 710] 1800] s*/e" |3000x3000%3200| 1110 | 3100 wersoost | 300] 180] v | v | v [225] 600/200] e+e" |3000%3000x3200] 1250 | 3300 \otapemee 5402507 1Pr 380% 203 =h Rueet ton oe | 1p toss one emp tone rere Sensor emp 3a Blelection chart of Cooling Towers ROUND COOLING TOWER SQUARE COOLING TOWER Delta T ‘APPROACH [APPROACH Delta 2]a]a]sle]7]s Pr oe eee a [10] a1] a2] a3 | 19 | a5 | a6 eee 6 9 [sof ar] az a3 | 14} as © flaaye | cap | ereel | ios 8 |e |s |ao] a] az] as} aa 3 |u| | as | as | 5 wo {7 |e ||] ar} a2} aa wo | io} | 2 | a3 | 2 a fs [7 [a] |olu}2 vw |o | wo] a | a | a lesion: wu |e fo |w|u | 2 Ine Temp of Tower eget empottower Det Wet Bu Teno Degc Water ow sine jig |Lo Lo JL jl toprox Desc eta eee ‘saporton oss = 0.0008 128 Fow at Daa ypical Installation Please installation of cooling tower below Do not Place pump above Instalation Method Sump outlet evel only ‘Sump outlet level By pplication ‘Automobile Industry, Cement Plants, Chemical Processing Industries, Diesel Engine Generators, Distilleries / Breweries / Soft Drink Manufacturing, Electronics Industry, Food & Beverage Industry, Glass Industry, Health Care / Hospitals Induction Furnace, Paper Mills, Plastic Machineries, Pet Bottle Machines, Spinning / Knitting / Hosiery Mills, Sugar Industry. etc... Speciation ar subject to change de to upgradation inal industries a A Manufacturers ‘Authored Dealer ) WIN EQUIPMENTS #106 8, S.N.R College Road, K..Puram, Coimbatore, ESuIRMER "TN~ 641 006, INDIA. Tele Fax: #91 422 2562975 — 1m: 491 9597 228 969, 191 9597 228 978, «: info@winequipments.com, URL: wwwuswinequipments.com hot line: +91 9597 228 975

You might also like