810 DOCUMENTS RENABLITATION AND TRANSFER OF THE EXISTING ‘OhVA POWER SECTIONY.—TEGINCAL SPECIFICATIONS TRANSFORMER, AT BOAC Sia INELUDNG SUPOLY, "el VER PART 1- TECHNICAL SPECIFICATI MISSIONING OF NEW ‘CIFICATIONS. TOMVA MOGPOG SUBSTATION PROJECT Luz re790tse E.1.5: MAIN CONTROL SWITCHBOARD TABLE OF CONTENTS 1.5.0 SCOPE,, 45.0.1 GENERAL 1.5.92 WORKS TOBE PROVIDED BY THE CONTRACTOR. 15.9.3 WORKS 10 BE PROVIDED By NPC 1.5.4 CODES AND STANDARDS 15.1.4 GENERAL... 1.8.2 TECHNICAL REQUIREMENTS 1.5.2.1 DESCRIPTIONOF SERVICES 15.2.2 DESIGN REQUIREMENTS: 152.21 General... 1.5.2.3. DESIGN AND CONSTRUCTION FEATURES, . 1523.1 Panel Construction... Mime Busos ane Egulpment Symbols PanelGubicle Wiring. Contre! Circuit Protection... Control System ‘Synchronizing System ‘Synchronizing Panel... Fault Annunciator System (Alarm System}, Indicating Instruments 40 Controf and Instrumentation Switehos. 11 Switchooard Accessories 4 METERING PANEL REQUIREMENTS 2.42 Watt-Hour Meters 24.3 Recordars 2.5 ‘TRANSDUCERS General... Watt-Var Transducers . Voltage Transducers . Current Transcuoers. Frequency Transducers. Transducer Panel 1826 Test Equiruenr mo Accessories . 1.5.2.7 OTHER TEGHNIGAL REQUIREMENTS FOR THE MAIN CONTROL SWITCHBOARO(S)... 4.8.3 INSTALLATION FACTORY ASSEMBLY AND TESTS .. 1 GENERAL. 4.2 Rounne Test. 4.3. Type Tests: DATA AND DOCUMENTATION REQUIREMENTS 1 GENERAL. 2 DATAAND INFORMATION TO BE SUBINTTED VAT THE PROPOSAL. 3_DATAAND INFORMATION TO BE SUBMITTED DURING POST QUALIFICATION... 4 DATAAND INFORMATION To BE SUBMITTED AFTER AWARD OF CONTRACT. NATIONAL POWER CORPORATION WEMCSH es BID DOCUMENTS: RENAAILITATION AND TRANSFER OF THE EXSTING 1OMVA_POWER SECTION VI-TECHNICAL SPECIFICATIONS TRANSFORMER, AT_ SOAC_ SS INCLUDING SUPPLY, DELIVERY CONSTRUCTION, INSTALLATION TESTING ANO COMMISSIONING OF NEW PARTI. TECHNICAL SPECIFICATIONS CONSTRUCTION, INSTALLATION TESTING Luxp14Z00i80 E.1.5: MAIN CONTROL SWITCHBOARD. 4.5.0 SCOPE 4.5.0.4 General 4.5.0.1 This specification cavers the technical and associated requirements for the conventional type of main control switchboard including all the various equipment and devices necessary for instrumentation and control requirements of a substation(s}. All materials and parts, which are not specifically mentioned herein but are necessary for the proper erection, assembly anc cperation of the equipment, shal be furnished at no increase in cost fo the NPC, 1.5.0.1.2 I is not NPC's intent to spectty all technical requirements nor to set forth those Fequirements adequately covered by applicable codes and standards. Tho Contractor shall furnish control switchaoarc meeting the requirements of these specification and industry standards, 16.0.1.3 The Contractor shall bear full responsibility that the control board has been designed and fabricated in accordance with all codes, standards and applicable governmentai regulations and performs under the conditions and to the standards spectfied herein. 1.6.0.1.4 No departure shall be made from these specification and standards unless waved or modified in writing by NPC. The Contractor shall cbtain from its subcontractors a statament as to compliance with this specification without oxcoption and/or if there are any exception, these shall be described in detail and included in Contractor's proposal, The Contractor shall add a statement that no olhar exceptions are taken to this specification. 18.0.2 Works to be Provided by the Contractor 1.6.0.2.1 The Contractor shall provide the equipment, accassories and services dalinested in Paragraph A.2, Section E.1.1 of the Technical Data Sheets. 15.03 Works to be Provided by NPC 1.5.0.3.1 NPC shall provide the materials and services (sted in Paragraph A.2, Section 1.1 of the Technicai Data Sheets. CODES AND STANDARDS. General 1.5.1.1.1 ‘The equipment furnished shall be in accordance with, but not limited to, the latest issues of the following applicable standards, including all adderda, in effect at time of purchase order unless otherwise stated in this specification. These shall include: ANSIIEEE American National Standards Institute and/or Institute of Electrical & Electronic Engineers 12,10 Electromechanicai Watthour Meters NATIONAL POWER CORPORATION VINCeT ‘BID COGUMENTS REHABILITATION AND TRANSFER OF THE EXISTING OVA POVER SECTIONVI— TECHNICAL SPECIFICATIONS TRANSFORMER AT BOAC SIS INCLUDING SUPPLY, DELWERT PART |- TECHNICAL SPECIFICATIONS CONSTRUCTION, INSTALLATION TESTING AND CONIVISSIONING OF NEW c12.16 033.10 033.65 037.1 oa7r.2 37.21 €37.90 ©37.90.1 €37.100 639.1 57.13 087.13.4 C87.13.3 255.1 8802-2, 10-6 ICBO UBC IGEA $-68-524 IEG 60051 60745 80214 80255 60258 60337 60356 60414 60473 60521 60825 60887 60688 1143 YONA HOGHCG SUBSTATION PROJECT hue 1sz3018¢ Solid-state Electricity Meters Safety Standard for Fuseholders Safety Standard for Cabinets and Fuseholders Standard Definition, Specification and Analysis of Systems used for Supervisory Control, Data Acquistion, and Automatic Control Standard Electrical Power System Device Function Numbers. Standard for Control Switeh Boards Standard for Relays and Relay Systems Associated with Power Apparatus Standard for Surge Withstand Capability (SWC) tested for Protective Relays and Relay Systems. Definitions for Power Switchgear Requirements for Electrical Indicating instruments, Standard Recuirements for Instrument Transformers Guide for Field Testing of Relay Current Transformers Guide for the Grounding of Instrument Transformers Gray Finishes for Industrial Apparatus and Equipment information Technology, Local & Metropolitan Area Networks, Parts 2,3,4,5 & 6 International Conference of Building Officials Uniform Building Code, Section 2312g Earthquake Reguiations Insulated Gable Engineers Association Crossed linked-thermosetting-polyethylene-insulated Wire and Cable for the Transmission and Distribution of Electrical Energy International Electrotechnical Commission (all parts of listed Standards apply) Direct acting indicating analogue electrical-measuting instruments and their accessories Var-hour (reactive energy} meters Maximum demand indicators, ciass 1.0 Electrical Retays Direct acting recording electrical measuring instruments and their accessories Control Switches Expression of the Performance of Electtical and Electronic Measuring Equipment Safety requrements for indicating and recording electrical measuring instruments and their accessories Dimensions for panel-mounted indicating and recerding measuring instruments Class 0.5 and 2 ac watt-hour meters An interiace system for programmable measuring instruments Alternating current static watt-hour meters for active energy Electrical Measuring transducers for converting ac electrical quantities Electrical Measuring Instruments - xt recorders NATICNAL POWER CORPORATION ViMCSE 81D cCUNENTS REHABILITATION AND TRANSFER OF THE EXISTING ‘OMVA POWER SECTION TECHNICAL SPECRIOHTIONS TRANSFORMER, AT_ CAC, SS INCLUDING | SUPoLy,” SEL WER) m. Tes HWS F NEW PART |- TECHNICAL SPECIFICATIONS CONSTRUCTION INSTALLATION TESTIN Lushtezpotge Iso International Standatds Organization 9001 Quality System Mode! for Quality Assurance in Design/Development, Manufacture and Testing 9002 Quality System Model for Quality Assurance in Production, Installation and Servicing SsPC Steel Structure Painting Gouneil PAI Shop, Field and Maintenance Painting PAZ Measurement of Dry Paint Thicknass with Magnetic Gages uL Underwriters Laboratorles, inc. (all parts apply) 44 Rubver-Insulated Wires and Cables 15.1.1.2 These codes and ctendards set forth minimum requirements which may be exceeded by Contractor if, in Contractor's judgment and with NPC's acceptance, superior or more econemic designs or materials are available for successful and continuous operation of Contractor's equipment as required in this specification. 18.2 TECHNICAL REQUIREMENTS: 15.24 Description of Services 1.5.2.1.1 ‘The control boards covered by this specification shall include all electrical features for complete control and instrumentation of a substation and/or switchyard. The application details are in Section E.1.5 of the Technical Data Sheets. 15.2.1.2 All materials and parts, which are not specifically mentioned herein but are necessary for the proper erection, assembly and safe oparation af the control boarcs, shall be furnished at no increase in cost to the NPC. 18.22 Design Requirements 16224 General 1.52211 — Tne main control switchboard shall be supplied complete with all instrument, meters, indicators, control switches, annunciators, push buttons, indicating langs, terminal blocks, wiring and miscellaneous devices as calied for by this Spectication or indicated in the Bd drawings. The conirol seard shall include all required auvillary and accessory devices auch as auxiliary current and voltage transformers, phase shifters, auxilary relays, resistors, etc, whether or not expressly called for or indicated on the bid drawings. All instrument scales, recorder charts, relay coils, contacts and other features shal! be suitable for the apparatus controlled or for the purpose intended. A large number of cables will be brought in through the bottom of the control board and adequate provisions shall be made to accammodata, support and terminate these cables on the terminal blocks. NATIONAL FOWER CORPORATION viness 81D DOCUMENTS REHABILITATION AND TRANSFER OF THE EXISTING 1OMVA POWER SECTIONVI-TECHNICAL SPECIFICATIONS TRANSFORMER AT OAC S/S INCLUDING SUPPLY, DELIVERY, CONSTRUCTION, INSTALLATION TESTING AND CORNMSIONING OF NEW TI Fi PART | TECHNICAL SPEGIFICATIONS ‘ONVA MOGPOG SUBSTATION PROJECT Laz? 18200156 1.5.2.2.1.2 The main control switchboard shall be designed and wired with relays and devices adequate to control not only the equipment supplied under this contrac! but iso the future equipment shown in the singie line diagram orin the substation layout. 1.5.2.213 The Contractor shall ensure that all equipment wilf allow sufficient room for ‘operation, maintenance, future additions and possible future feplacemert of defective components. 1.8.2.2.1.4 A basic single line diagram together with other layouts is included in the Bid Drawings issued with this Specification to give additional information on the extent, general locations and arrangement of the equipment. Bidders shall submit a tentative layout with the bid. 1.5.2.2.1.5 The Contractor shal ensure that all equipment he supplies, functions correctly and safely. 1.5.2.2.1.8 The characteristics and ratings of the equipment and devices given in the applicable sections are not necessarily the standards of any particular manufacturer but they aro the minimum requirements that must be satisfied by the Contractor. 1.5.2.2.1.7 The construction of the different parts of the Supply must be as standard as Possible in order to reduce to a minimum the spare parts ard to make the maintenance and replacement operation easy. All similar parts must be interchangeable. 1.8.2.2.1.8 The main control switchboard shall be complete with grounding connection and with all accessories and shall be euch as te guarartee correct and irouble free operations, 1.8.2.3 Design and Construction Features 1.8.2.3.1 Panel Construction 1.6.2.3.1.1 The control panel shall be of the type specified in the Technical Data Sheets either with 2 stationary mosaic panel on the front panel or 2 complete sheet steel front panel if required in the Technical Data Sheets. For control board adopting the mosaic tiles, the front Panel should conform to the adoption of both the mosaic tile for the upper (greater) part of tho front panal and sheet steel for the lower part of the front panel 15.2.3.1.2 For all types of control boards, the central panel shall be made of smooth sheet stee| panels with angle or channel frame and with edges bent to 6.0 mm radius, seam-welded at comers and ground smooth. The panels shall be bolted at the bottom to suitable stea! channel sills to be furnished as pert of this supply. Suitable grounding and anchor bolthotes shall be Provided in the channel sills. Butt joints on cutside surfaces shall not be permitted. Outside panels shall not be drilled or welded for attaching wires, resistors or other dovices where such holes or fastening will be visible from the front of the panei. All screws and bolts used for assembling members and panels and mounting wire cleats and devices shall be provided with lockwashers or other locking devices. Vertical edyes of panels shall be formed and boted togetner in such a manner that no part of edges are exposed to view. The panels shalt not daviate more than 1.6 mm from the true plane. To prevent warping of panels, all heavy devices shall be acequately supported by means of rear-mounted brackets or straps. 15.23.13 The cubicles or panels shall be constructed from a minimum of 2.0 mm sheet steel with edges formed into a rectanaular pattern or welded to steel shapes so that each section is rigid and self supporting and enclosed, NATIONAL POWER CORPORATION Pe) ViNoss BID DOCUMENTS REHABILITATION AND TRANSFER OF THE EXISTING 10NVA_ POWER SECTION VI- TECHNICAL SPECIFICATIONS TRANSFORMER AT GOAC SIS INCLUDING SUPPLY, DELIVERY, PART | TECHNICAL SPECIFICATIONS CONSTRUCTION, INSTALLATION TESTING AND COMMISSIONING OF NEW TOMVA MCGPOG SUBSTATION BROJECT ue 182001 80 1.5.2.3.1.4 End plates shall be removable to facilitate future extension of the control board. 1.5.2.31.5 The panels, trim, doors and frames shall match and ehall present a neat appearence when assembled. Electrical clearance shall be provided without cutting away the adjacent steel framework. Vents or iouvers shall be provided, where required, to give adequate ventilation. All ventilation openings and all opening in the floor shall be provided with screens to prevent entrance of insects and rodents. Thermostaticaliy controlled heaters with switches shall be fumished for prevention of condensation. Heaters shall be suitable for the voltage eource specified in the Technical Data Sheets of Section £.1.5. Switchboard shall have fixed panels on the front panel and shail utilize the end panels for future extansions. 1.8.2.3.1.6 The design of the control board and arrangement of devices shall be such that adequate space is provided for inspection and maintenance of wiring, torminals and equipment. Equipment inside the panels shal be so mounted that the studs of the equipment mounted on the panels wil be accessible without removing any device. American Standard device number shall ke used and marked on the rear of the panels near the corresponding cevice. The device numbers shall be merked legioly with permanent marking fluid that will form a contrast with the panel finish, 1.8.2.3.1.7 _ The phase arrangement when facing the front panels shall be A-B-C ftom the left to right and from top to bottom. All relays, instrument, other devices, busses and equipment involving three-phase circuits shall be arranged and connected in accordance with this phase arrangement whenever possible. Similar devieae chal be wired in a similar manner. 1.5.2.3.1.8 Provisions for future equipment and devices shall also include cutoute and blank covers having an outline the same as that of the future devices and with cotor the same as that of the board. The covers shall have concealed fasteners which shall be one (or some combination) of the following kinds: a. Threaded studs welded on the rear of the covers, with the studs projecting through standard drling (such as screw holes for mounting of future control switch escutcheons) b. Threaded studs welded on the rear of the covers, with the studs projecting through comer spaces in Doard rectangular cutouts (such as for thase instruments which do net require individual ecrew holes for standard mounting} ¢. — Sran-in welded on the rear of the covers, in positions or locations indicated above for threaded studs, 1623.9 For a dual type switchboard, the main control ewitchboard and sections shall include hinged doors. The hinges of all doors shall be fully concealed type and shall allow the doors to swing through by not less than 105° from the closed position. Stops or restraining chaing shall be provided where required limiting the swing and preventing damage to hinges. Each door shall be provided with 2 three-point locking catch anc with chromium plated level handle and pin tumbler locking mechanism with keys removable in both locked and unlocked positions, All locks shall be keyed alike. Two keys shall be fumished for each lock supplied. 1.6.2.3.1.19 The dimensions of a single panel shali be as follows unless otherwise specified in bid drawings and/or the Technical Data Sheets: a) Depth 70 mm NATIOWAL POWER CORPORATION veMees BID DOCUMENTS REHABILITATION AND TRANSFER CF THE EXISTING 1OMVA POWER SECTIONVI- TECHNICAL SPECIFICATIONS TRANSFORMER AT BCAC S'S CLUDING SUPPLY, DELIVERY, PART TECHNICAL SPECIFICATIONS. CONSTRUCTION, INSTALLATION TESTING AND CONMISSIONING OF NEW JDMVA MCGPOG SUBSTATION 2ROJECT LusPre2s0156 b) Width 800 mm (minimum) ¢) Height 2200 mm (maximum) 1.5.2.3.1.11. Controf switchboards shall be assembled from individual panels and shall be such that wiring and equipment for each main circuit is clearly separated from the others. All panels and sections of panels shall be clearly labeled from the front and from the rear. Rear-mountad auxiliary relays shall bo mounted as to alow free access to witing and panel mounted equioment. 4.6.2.3.2 Mimic Buses and Equipment Symbols 1.5.2.3.2.1_ Arrangement of switches, meters and relays in the crawings accompanying this specification are only indicative and shown only for reference purposes. The manufacturer of the panels could propose their own arrangement and layout based on the actual size of meters and relays that will be supplied. 4.5.2.3.2.2 For control board adopting the mosaic tiles, part of the panel comprising the mimic diagram, annunciators, discrepancy switches, indicating lamps, push buttons and meters shall be fitted with clip fitting mosaic tiles preferably 25 x 25 mm for easy exchange of mdividual block. ‘The control board shall be so dimensioned that it can be adapted fo the future extension possibilitios of the substation. 1.5.2.3.2.3 The control switchboards shall have mimic buses and symbols which shall provide ‘a simple and clear representation of the substation. It shall be in accordance with the single line diagram and, as far 28 possible, also with the physi¢al layout of the substation. All symbole used shall correspond to cithar ANS) of IEC Standard. Transformer, reactor and capactor bank symbols shall be backlit when it is operating and shall flash for unit alarms. Discrepancy type control switches and position indicators with discropaney function shall ke incorporated in the mimic diagram for all circu breakers, disconnectors and earthing switches. 1.6.2.3.2.4 — Mimic bus shall be arranged for adequate operation and as shown on the single {ine diagram and panel arrangement drawings. Mimic buses shall be at least 6,0 mm (4") wide Color-coding shall be as follows: 500 kv Golden 230 kV Vermilion Red 138 «Vv Bright Red 115 KV Orange 68 KV Medium Yellow B45 KV Maroon 13.8 kV Silver Bright 4.18 kV Silver 480 V Blue Ground Medium Green 1823.3 Panel/Cubicle Wiring 45.2.3.3.1 Wires shall be 600 V, stranded copper conductor with thermoplastic insulation, and shall comply with the requirements of ICEA Standard No. S-61-402, Minimum size shall be 2.0 sq., mm. or larger for control circuit excent annunciator wire which shall be 1.2 eq. mm. er larger. Minimum test voltage shall be 2000 V at 60 Hz. NATIONAL POWER GORPORATION ViMees BID DOCUMENTS REHABILITATICN AND TRANSFER OF THE EXISTING 10MVA POWER SECTION VI- TECHNICAL SPECIFICATIONS TRANSFORMER AT BOAC S/S INCLUDING SUPPLY, DELIVERY, PART TECHNICAL SPECIFICATIONS CONSTRUCT.ON, INSTALLATION TESTING AND COMMISSIONING OF NEW TOMA MOGPOG SUBSTATION PROJECT LuzPrazeoise 1.6.2.3.3.2 All wiring shall be neatly run and sacurely fxed in such @ manner that wherever practicable, wiring oan be easily checked against diagrams. 182333 As far as possible, all circuits shall be run along the shortest path to their addresses but shall be run only in horizontal and vertical planes. Diagonal runs ate not acceptable, However, the wire runs shail not block access for ready test or removal of any device without disturbing other devices. 1.8.2.3.3.4 if wiring is provided between swinging pancls, bundled conductors shall be used on the hinged doors or panels with extra/fexible wire, so arranged that a twistng rather than a bending motion is imparted to the moving bundled conductors. Each bunele shall bo anchored such thet the moving bunele length is the maximum available without loops, 18.23.35 Conductors within cubicles and between terminal blocks and apparatus shall be laid in plastic ducis or covered with plastic bands. 1.5.2.3.3.6 All power circuits, control and protection wiring and low level signal shall be physically separated. Separate laying-way shall be provided for power cables, and the working voltage of each power circuit shall bo marked on the associated boards. 1823.3.7 Conductor ends not connected to comprescion-type terminal books shall be provided with approved claw-weshers, which neatly retaln all strands, "Push-on” of “quick” type connectors shall be used for current transformers and trip circuits. ‘These connectors maybe used for alarm and contro} system and within en equipment assembly only. Sample of any such connectors shall be submitted for NPC's aporoval 1.5.2.3.3.8 Wiring shall be arranged to give easy access to the terminal or relays and other apparatus, 1.2.3.3.9 — Soldered or wire strapped connections shall only be inside electronic systems. Any wire wrapping shall be in accordance with IEC Publication 60382. 1.5.2.3.3.10 As far as reasonably possible, all outgoing wiring shall be grouped by function (CT, VT, Trip, Alarm, etc.) with those going to a commen destination allocated to adjacent terminal blocks. Terminal block contiguration shall be submitted for NPC's approval. Labels shall be provided on the fixed portion of the terminal boards showing the function of the group. 15.2.3.3.11 Connections for indicating instruments, and for the telecommunication circuits from transducers, or modem outputs, shall use individually shielded wire pairs. One (1) extra terminal per pair of termina's shall be provided fo connect this shield te ground 1.523.312 Witing required to interconnect shipping sections shalt be terminated on a terminal board in one section, to which the loose wires of the other section will be connected when the sections are assembled. All wiring from a section thal must cross the shipping spilt shall be terminated in the last section of the split and the interconnecting wiring shall be arranged so that the wiring extends between the two adjacent compartments. The wiring shall be tagged, bundied, terminated and then pulled back Inte one of the section. 18.23.4 Control Circuit Protection 152.341 The control branch circuits shall be protected by 600 volt rated indicating type fuses having the required interrupting capacity. Each branch circuit shail be identified with a vais? NATIONAL POWER CORPORATION Ep 31D DCCUNENTS REHABILITATION AND TRANSFER OF THE EXISTING {ONVA POWER SECTIONVI-TECHNICAL SPECIFICATIONS TRANSFORMER AT. OAC S'S INCLUDING SUPPLY, DELIVERY, CONSTRUCTION, INSTALLATION TESTING AND CONBISSIONING OF NEW. = TECH i J PART > TEGHRICAL SPECIFICATIONS TOMA MCGPCG SUBSTATION PROJECT LuzP12Z90180 Nameplate. The control circuit positive, negative and trip legs shall be sequentially wired from terminal to terminal to penrit supervision of the circuit by @ lamp andior supervisory relay connecied fo the end of the circu, 1.5.2.3.4.2 Potential circuits, for instrumentation, and for metering, shall be provided with 250 volt, and appropriate fuses located in such a pesition that they are easily and safely accessible. Each fuse and each set of fuses shall be fully identified for potential origin and equipment supplied. 1.6.2.3.8 Control System 1.8.2.3.5.1 _ The control system of the substation if required in the Technical Data Sheets of Section E.1.5 shall be designed for remote and local operation and indication. All interface devices and other accessories necessary for the remote central function snall be provided oy the Contractor, if indicated in the Techrical Data Sheets. 1,6.2,3.5.2 — The design of the control system shall make it easy to add new control devices, indicators, and meters, mimic objects, ets. and future modifications and extension of the contro! board. Modifications shall be possible with minimum interference to the operation af other parts of the instalation. 1.5.2.3.5.3 The control system for manual operations from the ccnirol room shall ba of an acknowledgment type. Manual operation shall be possible from the contral room for circuit breakers, disconnect switches and tap changers (if tap changer is required to be installed al the control board). It shall be possiole ta initiate all control actions necessary fer the daily operation of the substation from the main control board. 1.8.2,3.5.4 The control system shall be designed to allow remote contro! of the substation (ie. outside the substation) from the Remote Centers (ACC, RCC, NCC), if required in the ‘Technical Data Sheets of Section E.1.5. It shall also be possible to transfar all control functions in the main controi board to these remote centers. Such provisions ikewise prevent simultaneous control operation from two or more locations. Selectivity in tarms of priority shall be made available in the main control board. Statistica! indications shall always be available at main control board and remete focations, 1.8.2.2.5.5 If required in the Technical Data Sheets of Section E.1.5, remote supervision of the substation shail Ikewise be possible from the Remote Control Centers (ACC, RCC, NCC). The control system and main control board shall be designed for connection to Remote Control Centers. Supervisory data acquisition items shall be as follows, and shall be made available at the Remote Control Centers. Statistical indications Frequency Bus Voltage Line MW and MVAR Transformer MW and MVAR Line Mi¥h and MVARh Position indication Gircuit Breakers Disconnect Switches Earthing Switches NATIONAL POWER CORPORATION ViMeee BID DOCUNENTS: REHABILITATION AND TRANSFER OF THE EXISTING ‘OMVA POWER SECTIONVI-TECHNICAL SPECIFICATIONS TRANSFORMER AT GAC SIS INCLUDING SUPPLY. DELIVERY, PART | TECHNICAL SPECIFICATIONS. CONSTRUCTION, INSTALLATION TESTING AND GOMMIESIONING OF NEW SOMVA MOGPOG SUBSTATION PROJECT LuzP 19230156 Tap Changer/s Group Alarms 15.23.56 Each contact for position indication and group alarm cedicated for connection to Remate Control Centers shall be potential tree. Transducers for the above mentioned remoto statistical incication shall bo included in this supply Contract. The transducer’s output signal requirements for statistical indication are described in appropriate topics dealing with the remote terminal units (RTU's) and communication equipment. 1.8.2.3.5.7 Selection for the location of sentrol operation is to be made via selector switch with two positions located at the main control board: Position 4 Remote contral (ACC, RCC, NCC) Position 2: Local control 1,8.2.3.6.8 Group alarms and position of circuit breakers, disconnect switches, earthing switches and tap changer/s shall be sent to Remote Contro! Centers, irrespective of control location selector switch position mention in Paragraph 1.5.2.3.6.7. 1.6.2,3,8.9 The control operation and position indication of circuit breakers, and disconnect switches; and position indication cf earthing swilches shall be through miniature discrepancy ‘type switches, 1.5.2.3.5.10 _If the position of the discrepancy switch is not in accordance with the position of the substation equipment, the discrepancy switch shall show a flashing light and 2 synthesized acoustic signal shall be emitted after an adjustable delay of 5-15 sec. 1.8.2.3.5.11 All controls shall be operated at station battery voltage specified in the Technical Data Sheets of Section E.1.5. Signals for the position indication of circuit breakers, isolators and earthing switches shall be separately fed from individual terminal blocks. 1.5.23.5.12 Facilities shall be provided for common lamp test Lamps shall be easly removable from the front, have a voltage rating of at least 33 % higher than the nominal supply vokage. 1.5.2.3.5.13 Interlocking circuit shail be included and the following interlocking concept shall apply: a The disconnect switch shall be interlocked so as to be free from switching with the load current and charging current associated with the main bus. The disconnect switch shall be operable only when the relevant circuit breaker is in the off-position and that the earthing switch have been cleared b. The earthing ewitch ie operable only when the isolators have been opened and that the relevant location is perfectly tree of voltage. ¢. The closing of circuit breaker shall only be possible when the relevant protective relays end corresponding lock-out relays have not actuated, or if they have actuated; the faults have been cleared and the respective lock- NATIONAL POWER CORPORATION ViNeee BID DOCUMENTS REHABILITATION AND TRANSFER OF THE EXISTING 1oMVA POWER SECTION VI-TEGHNICAL SPeciFcaTIONS TRANSFORMER, AT SOAC SIS INCLUDING "SUPPLY, DELNERY PARTI TECHMGAL CONSTRLCTON, INSTALLATION TESTING AND COMMISSIONING OF NEW "ARTI TE SPECIFICATIONS JOMVA MOGPOG SURSTATION PROJECT Luar az00tse out relays have been reset See Paragraph 1.5.2.5.6 for synchronizing chack requirements, ¢. When a law: pressure signal is received from gas monitoring dovicss for a SF circuit breaker, the tripping and the closing signal shall be locked out. At the first level, closing signals shall ba locked out; and at the second level, bath closing and tripping signals shall be locked out. 2 The interlocking system is to be designed in such 2 way that it can be tested 1.6.2.3.6 Synchronizing System 1.5.2.3.6.1 | When specified in the Techrical Data Sheets, a synchronizing equipment separate from that used for auto-reclosing shall be provided for the substation for controling manual closing of circuit breakers. This shall also control remote closing orders from any of the Remote Control Centers if specified In the Technical Data Sheets of Section E.1.5 15.2.2.6.2 — The equipment shalt be common for all circuil breakers and shall be provided with an integrated voltage-check and synch‘o-check functions. The voltage-check function shall include live-bus/dead-ine conditions, dead-bus/ive-line conditions and cead-bus/deadine conditions. Jt shall be possible to set or select which one or combinations of these conditions that will allow closing. For live-bus/live-line conditions synchro-chack function shall take precedence. 1.6.2.3.6.3 Dead conditions shal! be detected when the voltage of a bus or line is measured to be less than about 20% of the rated voltage. Live condition shall be detected when the Measured bus or line voltage is greater than 80% of the rated voltage. 1.23.64 — The synchro-check function of the equipment snail allow circuit breaker closing only if the voltages on both sides of the breaker fulfil the preset conditions as to magnitude, phase angle and frequency difference. The vollages are considered to be in synchronism when thelr phase angles are considered to he within the preset angle, adjustable from 26° to 60° 15.2365 A synchronizing switch shall be provided for each circuit breaker which will automatically connect the voltage circuits related to the breaker being closed to the synchronizing equipment. The equipment system shall be designed in such a way that it shall not be possible to inadvertently interconnect the voltage circuits, even when two or more synchronizing switches are closed at the same time, 1.5.2.3.66 — Also, when performing synchronizing at the contro beard, provision shall be made such that closing order, from any of the Remote Control Centers will be blocked. A sultable means shall be provided for this purpose. 152.3.6.7 _ Isolating transformers shall be provided for all input voltages to the synchronizing equipment te provide galvanic separation of the equipment from the remainder of the substation, 15.2368 Auxiliary relays shall be provided to supervise or block closing orders when the permissible closing conditions are not satisfied. 15.2369 — The synchronizing equipment shall be mounted on a 19-inch standard rack frame or on the main control board as directed by the NPC and must have the following synchronizing points positions: Local Auto-Remote Auto-Manual-Tast NATIONAL POWER CORPORATION a aT BID DOCUMENTS. REHAAILITATION AND TRANSFER OF THE EXIETING 10MVA POWER SECTION VI TECHNICAL SPECIFICATIONS TRANSFORMER AT GOAC SIS INCLUDING SUPPLY, DELIVERY, PART1- TECHNIGAL SPEGIFICATIONS CONSTRUCTION, INSTALLATION TESTING AND COMMISSICNING OF NEW ‘TOMA NOGPOS SUBSTATION PROJECT Luz 14200186 1.5.2.3.7 Synchronizing Panel 1.8.2.3.7.1 In addition to the integrated synchronizing equipment, a separate synchronizing unitipanel provided with two frequency meters, two voltmeters, and a synchroscope shall be installed on the control panel to interface with the operator during manual synenronization Voltage inputs to these units shail also be controlled by the synchronizing switches. The synenronizing panel shall be attached to the upper left comer of the Main Control Switchboard, 1.5.2.3.7,.2 It shall be possible to move or swing the synchronizing equipment so as to bring it in sight from ary point along the switchboard during the synchronizing operation and to return it to its original position when not in use. 1.8.2.3.7.3 Provision shall be made such that when performing synchronizing using the synchronizing panel, closing orders from any of the Remote Control Centers shall be blocked. 1.5.2.3.7.4 The panel shail be epproximately 200 mm deep. The back of the synchronizing panel shall be readily removable for access to the interior. The panel design shall permit ready remeval and relocation of the panel when additional control switchboard sections are installed. 1.8.2.3.7.8 Synchronizing lamps, shall be special incandescent synchronizing typo with medium base keyless sockels, The lamps shall be connected so that they wil be “dimmed” when the incoming and running circuits are in synchronism. Vibrating reed type frequency meters are not acceptable. 16.2.3.7.6 Synchroscopes shall be furnished with indication pointe: rotating 180 mechanical Gegrees for a change of 1€0 electrical degrees in the relative phase of the incoming and running synchronizing potential circuits. The synchroscope shall operate satisfactorily over a range of 80 te 180 V with the pointer coming to a stap when potential to either incoming or running circuit is lost, The synchroscope shall have full 360° scale and shall be marked to show synchronism point and to indicate whether the incoming circuit is fast or slow in synchronism. 15.2377 The legend “INCOMING” shall be marked on the left or top frequency meter and volimeter scales, and the legend "RUNNING" shall be marked on the right or botlom frequency meters and voltmeter scales. 4 3.8 Fault Annunciator System (Alarm System) 15.23.81 The annunciator system shall distnguish any abnormal conditions during ‘operation in the control room by means of visual and audible warning. 1.5.2382 Under normal conditions, the annunciator relays shall be de-energized so that there will ke no power drain on the DC system when all trouble points are normal. However, the design of the annunciator system shall be based for continuous operation of all alarms simukaneously. 15.23.83 The annunciator system shall be of modular design and microprocessor based, designed for operation on 2 DC supply system specified in the Technical Data Sheeis of Section E.1.5 It shal consist of wincow cabinets, mounting chassis, plug-in relay assemblies, flashers, alarm relays, isolating relays, lamps, test buttons, acknowledged and reset buttons. It shell be mounted on a stancard 19° rack as a separate panel or Integrated In tne main control beard as directed in the Technical Data Sheets of Section E.1.5. ViMeT NATIONAL POWER CORPORATION o> 8/0 DOCUMENTS REHASILITATION AND TRANSFER OF THE EXISTING 1OMVA POWER SECTION VI= TECHNICAL SPECIFICATIONS TRANSFORMER AT BOAC SS NCLUDING SUPPLY. DELNERY, CONSTRUCTION, INSTALLATION TESTING ANO COMMISSIONING OF NEVE °ART 1 TECHN L. ° ICAL SPEGIFIOATIONS 4OMVA NOSPOG SUBSTATION PROJECT Lus1ez001se 16.23.84 Relays and flashers shalt be of the draw out type ard shall be capable of being easily repaired by parts replacemerts. Relay assemblies shall be interchangeable, 1.5.2.2.8.5 The supply voltage for the annunciator eystem shall be monitored and must give an alarm in case of interruption of the alarm equipment power supply. 1.8.2.3.8.6 Each alarm relay shalt have en auxiliary relay with multiple contacts for local alarm, sequence of event recorder (SER), Atea Cortrol Center (ACC) and spare, In addition, group alarms for circuit breaker, transformers, ete, shall also be available, All alarms shall work independent of other alarms, synthesized audible and visual alarm shall function in the following sequence: 2. Fast fleshing visible alarm light and synthesized audible alarm shall commence when an alam occurs. This shall continue unfil acknowledged, whether the fault has been automatically or manually cleared or not. b. When the alarm is acknowledged, the audible alarm shall cease while the light shall cease only if the fault has lixewise ceased or have been cleared or the alarm initiating equipment has reset. if the fault has not ceased or have not been cleared or the alarm initiating equipment has not reset, the visual indication shall change to a steady light. & Pressing the lamp fest bution, all lamp relays will operate and lamps shall light-up, but without audible sound, 1.5.2.3.8.7 The annunciator window shall be color ceded for immediate distinction of the type of alarm. Red for ertical alarm and white for non-critical alarm. 1.5.2,3.8.8 — Critical alarms are those which cause tripping and trip indications. Critical alarms and non-critical alarms are freely convertible from one ta the other type. 15.2388 — The auxiliary equipment for the fault signals shall be designed in such a manner that it will enable group tesiing of the relays. 1.8.2.3.8.10 The time delay shall be individually adjustable and the setting range shall be between 0 and 30 seconds in steps of 1 seconds. 15.2.3.6.11 Alarm, which is inklated from possible discrepancy between the status of the ‘object controlled and the position indicated on the control switch (Le. discrepancy switch), shall have a time delay which is adjustable from 0 to 30 seconds in steps of 1 second. 1.523.812 Two diferent kinds of audible alarms shall be provided; one for critical alarm and ‘one for non-critical alarm. In addition, a separate horn shall be supplied which will be installed at the substation area to call the attention of the people at the substation area when a critical alarm occurs. This horn will be wired to air critical synthesized audible alarm only. 15.23.8.13 Each kind of audible alarm shall have different sound which are eubject to the approval of the NPC. 1.5.2.3.814 Acknowledgment push butions and switches or lamp test shall be one separate set for each of the annunciator, VERS NiRTIONAL POWER CORPORATION ree) +

You might also like