STEPS

 CONNECT ONE END OF THE ETHERNET CABLE TO CLIENT (LAPTOP) AND THE OTHER END TO
DUW USING PORT LMT B.

 CONFIGURE CLIENT LOCAL IP


By: Ehab ALQAYSI
Telecom Engineer

 LAUNCH EMAS (ELEMENT MANAGER) AND CLICK ON SELECT TAB

 FROM THE SELECT TAB, CHOOSE IP


By: Ehab ALQAYSI
Telecom Engineer

 UNDER THE MO TREE, SELECT IPOAM=1

 ON THE RIGHT SIDE, SELECT MO PROPERTIES


By: Ehab ALQAYSI
Telecom Engineer

 UNDER MO PROPERTIES, SELECT ACTIONS

 UNDER ACTION, SELECT PING, ENTER THE IP OF THE OSS (10.29.11.164 OR 10.29.11.167),
CLICK ON EXECUTE.
IF IP IS ALIVE, MUB INTERFACE IS UP, IF NO ANSWER, CHECK WITH TX AND BSS.