DoePlayer BUFFER TANKS eNO ee ore Be cm Ud docplayer:nol21774054-uffer-tanks-asme-commercil-buffrtanks html 2assizor9 DocPlayer BUFFER TANKS a AMTROL. Amtrol ASME Buffer Tanks add capacity to non-potable, closed systems to help reduce cycling, improve temperature control and provide more consistent system operation, Available for chilled water and hot water applications, these Buffer Tanks are all made in the USA at our ISO 90012008 registered facilites Chilled Water Buffer Tank CWBT Series + Meets all ASME Section VIll, Division | standards. + Available up to 1,040 gallons. + Connections from 3” to 12" + Intemal baffle helps property circulate water. + Maximum Working Pressure: 125 or 150 psig. + Maximum Operating Temperature; 450° F. How It Works Water enters the buffer tank and is diverted up and over the internal bame to circulate the water and take full advantage of the tank volume, Typical Installation a Internal Bate ute docplayer:nol21774054-uffer-tanks-asme-commercil-buffrtanks html 26 2assizor9 DocPlayer aColMCS i teM TiC Maem cele Ce) Hot Water Buffer Tank HWBT Series + Meets all ASME Section Vill Division | standards. + Avaliable in 2 oF 4 port options. + Avaliable up to 300 gallons. + Avaliable in 2”, 3° & 4” connections. + Maximum Working Pressure: 125 or 150 psig. + Maximum Operating Temperature: 450° F. How It Works ‘Tank provides added capacity in high efficiency systems that incorporate ‘small, modular, lovemass condensing boilers + 4-port tanks allow for primary / secondary flow through the vessel. This Is usually required for systems with multiple small or low volume zones to maximize bolle efficiency and overall system performance. + 2-port tanks are typically used in standard applications wnere all zones are similarly sized, ‘System Flow > Boiler Flow ‘System Flow = Boiler Flow ‘System Flow < Boiler Flow: ot mo eq say elie es | t t Hees Sie ce, Piles, Hlvce. So > ion. hoo bilo. Typical Installations 2 Por Installation 4 Port installation oN — a docplayer:nol21774054-uffer-tanks-asme-commercil-buffrtanks html ais 2assizor9 DocPlayer Py r4tite Ma Cem rs ia For Adding Capacity to Closed, Non-Potable Hot Water Systems Required Information Manufacturer's , cnnmum borer ganar” aa? + Boiler Cyelo Time (minutes) eycletme" Suput teas + Minnum Boiler Output (BTU) + Minimum System Load (BTUIhe) - Butter + Temperature Differential °F) iu. pion’ TamkSuze inate _ Example: Temperature Boiler Cycle Time: -S minutes within tank Galens Minimum Boiler Output: 200,000 BTUs Minimum System Load: 25,000 BTUs 500 ‘Temperature Diffoental: 170° - 180° = 10° F Pipe Size 2 Raliet Vaive: SO PSI + Kine tear seem wad ate etroue 5(200,000- 25,000) _ . ~Senoersineatarores can rnge fam Se S0 OF wy — = 175 Gallons Recommendation: HWET200.2:125 a | Pll d of _ ua fei enensans ene) sonra woot wer@02 [2 [ao | 2 |e [sam [oem te | | 254 278 woffj-+ “wet1203 [2 | 120 | 3 | 24 [30 [sem] 10 | 15 | 5 268 | 205 rweT2002 | 2 | 200 | 2 | 30 | 30 [eam] 24 | orm |aom 475 | 523 Prev tl camos HweT2003 [2 | 200 | 3 | 30 | 39% [o2%| 24 [21] aar| - [aoa] s30 = sehen “awsT3002 | 2 | 300 | 2 | 36 | 45% [eo%| 30 |s2%]erm| - [ese] 736 b= Hwets003 | 2 | 300 | 3 | 36 | 45% [ao%| 0 | a2] 61 663 | 751 HweT12022[ 4 | 120 | 22 | 24 | sam [seu] 1 | 1 | 45 | 27 [oer] 204 . rwsT12026[ 4 | 120 | 2 | 26 | 33m [ sex] 16 | 15 | 45 | 27 | 252] 310 HweTt2036[ 4 [120] 33 24 [ase [sem] 6 | 16 | 45 | 27 [oar] 227 Hwerro4re| 4 | 190 | aa | 24 | 59% | som] 16 | 5%] aaa] 27%] a8 | are Hwer20022[ 4 [200 | 22 [30 | 30 [axa] 24 [av | asi 3 | 450] 538 rweT20026| 4 | 20 | 23 | 30 | 30 [spa] 24 [202 | asi) ss] 608] s63 Hwer20033[ 4 | 20_| 33 | 30 | sem [oz | 24 [ans [on [35% | 516 | 70 rweT200-41| 4 | 200 | a] 30 | 30% | ars] 24 | 205 | 45re| 35%| 500] 617 HWETS0022[ 4 [300] 22 | 36 | 45% | 60% | 30 | ava [orm | 48%] os] 760 Hwsrs0026| 4 [ 300] 23 | 36 | a6% [0% | 30 [32%] 61 | 48%| 096 | ree HweTs0036 | 4 [3007] a3 | a6 | 45% [eo% | 30 [32%] or [asia] 7x1] 702 rwers004| 4 | 300] a] 36 | 45% [ao] 30 [52%] ot [aaa] rao] oe docplayer:nol21774054-uffer-tanks-asme-commercil-buffrtanks html 46 2assizor9 DocPlayer Sizing Chilled Water Buffer Tanks For Adding Capacity to Closed, Non-Potable Chilled Water Systems Required Information Total Chilled Capacity in Tons ‘System Volume per Ton” ‘Actual System Volume in Gallons = V, Jol system surter chilea Yuma system = Tan Capacty Parton Volume Sop “Check with Chiler Manufacturer for specific requirements. ‘Typical HVAC chiller systems are between 3 and 6 gallons ( ) 2 per ton. Applications where temperature accuracy is ertcal requires 6 to 10 gallons, Tors GallonsiTon Gallons. Gallons © We) ™) Exampl Total Chiled Capacity (C}- 100 Tons ‘System Volume (V,): 10 Gallons Per Ton Actual System Volume (V,). 800 Galons Pipe Size: 4 Rell Valve: SO PSI (10x 10) - 800 = 200 Gatlons* Recommendation: CWBT200-4-425 GUL cwari2s | 120 | 3 | 24 | soe | som | to | te | 208 | 28 Gwari04 | 120 | 4 | 24 | 3a% | se | te | ism | os | 347 2. cwari20s | 120 | 6 | 24 | 3% | se | te | 10% | 333 | 366 ewsT200-3 | 200 | 3 | 30 | 30% | 62% | 24 | 21% | sor | 500 ewar2004 | 200 | 4 | 30 | ao% | oa% | 24 | 22 | sar | 002 cwsr200.6 | 200 | 6 | 30 | 39% | o2% | 24 | 23 | 500 | 629 ewaraoos | 300] 4 | a8 | 45 | ao% | a0 | am | 75a | 626 cwsrs006 | 300 | 6 | a6 | 45 | e0% | 30 | 35% | 772 | 49 Gwarso0s | 300] 8 | 38 | 45 | a0% | 90 | 34% | 001 81 cwsro0 | 500 | 6 | 42 | 51 | av | 30 | 0% | 1986 | 1500 ‘ewsts00-8 | 500. [8 | 42) st | oo | 30 [ar [1395 [1.535 ‘cwsrs00-10_| 500 | 10 | 42 | 51 | 9% | 30 | 30% | 1400 | 1,630 ‘ewaracos | 350 | 6 | 6a | oa [114m | a2 | so | 2707 | 2.076 cwaraco-s | 850 | 8 | 64 | o4% | 114%] 42 | 40% | 2796 | 3.010 ewaraso-0 | aso | to | s4 | em [tia | a2 [atm | 27m | 3006 ‘cwsti040.8 | too | 8 | ao | 70 | 107%] 45 | 36 | 3136 | 3450 ewari040-10 | 1040] 10 | eo) 70 | 107 | 45 [37 | 3.171 | 488 ewaT1040-12 | 1040 | 12 | 60 | 70 | 107%] 45 | 38 | 3283 | 36n1 docplayer:nol21774054-uffer-tanks-asme-commercil-buffrtanks html 5i6 2assizor9 DocPlayer Made in the USA a AMTROL. From modest beginnings in founder Chet Kirk’s garage to our current, state-of-the-art facilities, Amtrol is still proudly manufacturing products in the USA. Our talented, dedicated associates are committed to providing you with the highest quality, most reliable and best performing products on the market Associates at our West Wenuick, Rhode Island manufacturing Fit. Additional support materials include: + Commercial and industrial Products + Product Sizing programs on Catalog (MC 4401) weew amtrol.com + Data Submittal Sheets (MC 4400) + Revit Files (MC 10205) + Engineering Handbook (MC 4402P) + AutoCAD Files (MC 10029) hs Gia AMTROL ec 1400 Division Road, West Warwick. RI. 02869 USA == — “800 426.6785 F:300.203 1519 fain ezasniraoLin ‘wort amtrol.com we a 0115 docplayer:nol21774054-uffer-tanks-asme-commercil-buffrtanks html 86

You might also like