You are on page 1of 1

Problem 1

A 350mm x 500 mm rectangular beam is reinforced for c) Determine the maximum steel area under singly
tension only with 5 – 28mm dia bars. The beam has an reinforced condition.
effective depth of 446 mm. The beam carries a uniform d) Determine the maximum design moment
dead load of 4.5 kN/m (including its own weight), a strength under singly reinforced condition.
uniform live load of 3 kN/m and concentrated dead load
of P and 2P as shown in the figure. Assume fy = 414 MPa Problem 4
and f’c = 34.5 MPa. Determine the following: A reinforced concrete T-beam with an effective flange
a) The ultimate moment capacity of the section in base of 813 mm, effective depth of 300 mm, base of the
kN-m. web of 200 mm, thickness of the flange of 102 mm is to
b) The maximum value of P in kN. be designed to carry a factored moment of 221 kN-m.
Assume f’c = 30 MPa and fy = 414 MPa. Determine the
required area of steel reinforcement.

Problem 5
Determine the permissible ultimate moment capacity for
a symmetrical T-beam with a span of 5m. The width of
Problem 2 the web is 300mm, slab thickness of 90mm and the clear
Design a singly reinforced rectangular beam for a 6-m distance to adjacent beam is 3m. Steel reinforcement (6
simple span to support a superimposed dead load of 29 – 32 mm dia bar)is in double layer and the beam has an
kN/m and a live load of 44 kN/m. Assume normal weight effective depth of 600 mm. Assume fy = 345 MPa, and f’c
concrete with unit weight of 24 kN/cu.m. Use maximum = 21 MPa.
steel ratio and assume f’c = 34 MPa and fy = 345 MPa.

Problem 3
In a hollow beam shown below, assume f’c = 28 MPa and
fy = 345 MPa.

a) Determine the required tension steel area when


Mu = 800 kN-m.
b) Determine the balanced moment capacity of the
beam.

You might also like