7800 Ventilator Service Manual Product Group Codes CAT and CBA 7800 Ventilator Service Manual Product Group Codes CAT and CBA ‘This document is not to be reproduced in any manner, nor are the contents here in to be disclosed to anyone, without the express authorization of the Product Service Department, Ohmeda. Copyright © 1995, Ohmeda Inc FEO DOM TS00-008T-000 535 Important ‘The information contained in this service manual pertains only to those models of products which are marketed by Ohmeda as of the effective date of this manual or the latest revision thereof. This service manual was prepared for exclusive use by Ohmeda service personnel in light of their training and experience as well as the availability to them of parts, proper tools and test equipment. Consequently, Ohmeda provides this service manual to its customers purely as a business convenience and for the customer's general information only without warranty of the results with respect to any application of such information. Furthermore, because of the wide variety of circumstances under which maintenance and repair activities may be performed and the unique nature of each individual's own experience, capacity, and qualifications, the fact that customer has received such information from Ohmeda does not imply in any way that Ohmeda deems said individual to be qualified to perform any such maintenance or repair service. Moreover, it should not be assumed that every acceptable test and safety procedure or method, precaution, tool, equipment or device is referred to within, or that abnormal or unusual circumstances, may not warrant or suggest different or additional procedures or requirements. This manual is subject to periodic review, update and revision. Customers are cautioned to obtain and consult the latest revision before undertaking any service of the equipment. Comments and suggestions on this manual are invited from our customers. Send your comments and suggestions to the Manager of Service Education, Ohmeda, Ohmeda Drive, Madison, Wisconsin 63707 AXCAUTION: Servicing of this product should never be undertaken in the absence of proper tools, test equipment and the most recent revision to this service manual which is clearly and thoroughly understood. Technical Competence The procedures described in this service manual should be performed by trained and authorized personnel only. Maintenance should only be undertaken by competent individuals who have a general knowledge of and experience with devices of this nature. No repairs should ever be undertaken or attempted by anyone not having such qualifications. It is strongly recommended that genuine replacement parts manufactured or sold by Ohmeda be used for all maintenance, service and repair involving this product. Read completely through each step in every procedure before starting the procedure; any exceptions may result in a failure to properly and safely complete the attempted procedure. F800 DOM TSOO-O0T- 000 39S Table of Contents Important .. ‘V/Introduction 1.1 Note, Important, 1.2 Symbols. 1.3. Standard Service Procedures. Operation and Service Manuals... Bellows Assembly... Stock Numbers for Replacement Parts Ventilator tests.. 1.4 7800 Ventilator Configuration. The Ventilator is composed of two basic units The Ventilator is available in three configurations Differences in these configurations include A. Excel Mount, B. Stand-alone C. Modulus II Upgrade Product Group Code...... Piggyback Watchdog Board Software Versions. EMC/Interface Board Pressure Transducer Board aution and Warning 2/Theory of Operation 2.1 Ventilator Overview. ‘The Control Module The Bellows Assembly. 2.2 Pneumatic Description Gas Inlet Valve Pressure Regulation. Flow Control Valve. Exhalation Valve. Bellows Pressure Relief Valve. Free Breathing . Pressure Sensing. Filtering. 2.3. Electronic Descriptions Notation Within this Text Component Designations Power Cord. Filter, Breaker, Selector, Transforme 2-16 Power Supply Board (Original). Power Supply Board (Universal) Two Layer Control Board... 1. Power Source Selection [Sheet 3 of schematic, section 9].. HrOM BD ORD mpop TE00 DOM- 1S00-00BT-000 SOS Table of Contents BON on 7. 8. 9. 10. 11. 12, 13. 14. 15. 16. 17. 18. 19. 20. 21. 22. 23. 24, 25. 26. 27. 28. F. Front 1 ora EN 9. 10, 11. G. Pressure Transducer Board (Original. 1 Battery [Sheet 3]... System Power Up Relay [Sheet 3 Plus (+) 7.5 V de and Minus (-) 7.5V de [Sheet 3]. ELL. Panel Driver [Sheet 3]........ sn B18 Power Up RESET and Program Flow Watchdog Timer [Sheet 1].. 2-16 x 16 EEPROM [Sheet 1] Microcontroller Oscillator [Sheet RS-232 Interface [Sheet 1]. Microcontroller [Sheet 1 Memory Address Decoder [Sheet 1]. 64K Program Memory [Sheet 1] BUS TRANSCEIVER [Sheet 1] 8K Static RAM [Sheet 1 Address Latch (Sheet 1] 8-BIT Output Port [Sheet 1] 8-BIT Input Port [Sheet 1]. +4.5 Voltage Reference [Sheet 2]... Patient Pressure Analog Output [Sheet 2]. Flow Control Valve [Sheet 2) Flow Control Valve Drive / Sense [Sheet 2]..-..r0- : 2-22 Oxygen Analog Output [Sheet 2] 2-22 LCD Contrast Driver [Sheet 2]. ; AID Converter [Sheet 2].. 2-24-Channel Multiplexer [Sheet 2].. System OK / Valve Interlock [Sheet 2].. Exhalation Valve Drive and Sense [Sheet 2] Gas Inlet Valve Drive and Sense [Sheet 1 and 2] Panel Board. System Fail Logic [Sheet 1 of Schematic, Section 9]. LED Alarm Indicators [Sheet 1]. Liquid Crystal Display [Sheet 1]. Front Panel board Input [Sheet 1 Front Panel Switches [Sheet 1].. TVX (Volume Transducer) Input {Sheet 1]. Oxygen Sensor Input [Sheet 1 Control Potentiometers [Sheet 1] Audio Alarm [Sheet 2] Touch Detection Circuit [Sheet 2] Flow Control Valve Interlock [Sheet 1] PPP PEPE EYER Cee e keke wens SSSSSS88 S600 Power Supply. wert "FEOO BOM - TEO0-0OBT-O00 35 Table of Contents Voltage References. Patient Pressure Circuit. ‘Temperature... Supply Pressure Circuit. H. Pressure Transducer Board (Universal) . 1, Power Supply [Sheet 2].. 2. Voltage References [Sheet 2] 3. Patient Pressure Circuit [Sheet 3] 4. Supply Pressure Circuit [Sheet 1] I. Piggyback Watchdog Board J. EMC/Interface Board... geen 3/Post-Service Checkout Test the Ventilato: Test the Anesthesia System. Test all Options and Accessories. .. 4/Tests and Calibration. 4.1 Overview. Testing Requirements Viewing Displays in Another Language. 4.2 Bellows Assembly Tests... A. Visual Inspection. B. Bellows Assembly Leak Tests Tools Required. Bellows Retention Te: Pressure Relief Valve Test. 4 Bellows Drop Test... 4 Pressure Leak Test 4 Leakage (without Bellows Assembly) 00cm Leakage (with Bellows Assembly)......... 4. 4. 4. A. 4 C. Additional Bellows Assembly Tests 4.3 Control Module Tests A. Power Supply Test. Tools Required. : B. Checking User Parameters, 4.xx Software, C. Service Calibration Mode, 4.xx Software... Tools Required. Check the Watchdog Timer Check the Contrast Check the 4.500 Volt Reference Measure the Oxygen Output Reference. 2 5. Check the Analog to Digital Conversion of the Oxygen Output 6. Measure the Patient Pressure Output Reference... . OdOdHAOHHOOHDE BOE ONE 700 DOM TS00-00BT-000 SOS wee Table of Contents 7. 8. 9. 10. 11. 12. 13. 14. 15. 16. 17. 18. Pushwheel Checks......... 19. 20. 21. 22. 23. 24. 25. 26. 27. 28. 29. 30. 31. Check the Secondary Regulator Calibratio: Check the Primary Regulator Calibration. 32. 33. 34. 35. 36. 37. 38. 39. 40. Check the Analog to Digital Conversion of the Patient Pressure Output... Check the CPU Check the EPRO! Check the EEPROM. Check the RAM.. Check the Mechanical Ventilation Switch. 7 Check the Inspiratory Pause Button... Check the DIP Switches : Check the Tidal Volume Knob... Check the Rate Knob. Check the Inspiratory Flow Knob Check the Inspiratory High Pressure Limit Knob. Check the Low Minute Volume Limit Pushwheels.. Check the Low Oxygen Limit Pushwheels Check the High Oxygen Limit Pushwheels. Check the Back-Light. Check the Audio Volume. Check the Exhalation Solenoid. Check the Inlet Solenoid... Check the Patient Pressure Sensor Calibration. Check the High Pressure Sensor Calibration Check the Flow Control Zero Calibration Check the Flow Control Gain Calibration Regulator Calibration Setup... Check the Regulator Pressures Volume Transducer Input Setup.. Check the Flow Detection. Check the Analog to Digital Conversion of Flow Valve Drive... High Pressure Limit Setup. Check the High Pressure Limit . Check the Altitude Setting. Check the Temperature Sensor... Flow Calibration Status Check the Drive Gas Selection. F800 DOM 100 WOBT-000 355 Table of Contents 41. Check the Flow Control Valve Serial Number. 42. Check the Flow. 43. Check the 02 Sensor.. D. Checking User Parameters, 1-xx Software E. Service Calibration Mode, 1.xx Software. Tools Required. Enter the Service Routine. Check the Contrast. Check the 4.500 Volt Reference Measure the Oxygen Output Reference. Check the Analog to Digital Conversion of the Oxygen Output... 6. Measure the Patient Pressure Output Reference. = renee 4-50 7. Check the Analog to Digital Conversion of the Patient Pressure Beye s Output 8 Check the CPU.. 9. Check the EPROM... 4-51 10. Check the EEPROM . 4-51 11. Check the RAM.. 4-52 12. Check the Mechanical Ventilation Switch... 13. Check the Inspiratory Pause Button 14. Check the DIP Switches 15. Check the Tidal Volume Knob 16. Check the Rate Knob. 17. Check the Inspiratory Flow Knob 18. Check the Inspiratory High Pressure Limit Knob. Pushwheel Checks 19. Check the Low Minute Volume Pushwheels.. 20. Check the Low Oxygen Limit Pushwheels. 21. Check the High Oxygen Limit Pushwheels. 22, Check the Back-Light. 23. Check the Audio Volume 24. Check the Exhalation Solenoi 25. Check the Inlet Solenoid. 26. Check the Patient Pressure Sensor Calibration 27. Check the High Pressure Sensor Calibration .. 28. Check the Flow Control Zero Calibration . 4-66 7800 DOM 1500 008-000 FOS TeV Table of Contents 29. Check the Flow Control Gain Calibration . 30. Regulator Calibration Setup... 31. Check the Regulator Pressures Check the Secondary Regulator Calibration... Check the Primary Regulator Calibration 32. Volume Transducer Input Setup. 33. Check the Flow Detection. 34. Check the Analog to Digital Conversion of Flow Valve Drive 35. High Pressure Limit Setuy : 36. Check the High Pressure Limit 37. Check the Altitude Setting. 38. Check the Temperature Sensor. 39. Flow Calibration Status 40. Check the Drive Gas Selection. 41. Check the Flow. 42. Check the O2 Sensor. 43. Check the Watchdog Timer F. Touch Sense Test G. Leak Test. Tools Required. H. Ground Impedance Te: I. Leakage Current Test... Tools Required... . End of Test and Calibration 5/Maintenance 5.1 Maintenance Schedul 5.2 Maintenance Procedures...... Exhalation Valve Maintenance. Free Breathing Valve Maintenance.. Gas Inlet Valve Maintenance Secondary Regulator Filter Replacement Testing After Maintenanc adbodvoss anannana 6/Troubleshooting 6.1 General Information..... 6.2 Troubleshooting Guide 6.3. Ventilator Failure Messages. 7/Repair Procedures 7.1 General Information. Ground Wires Lubricate O-rings 7.2 Control Module Removal, Test Setup and Installation... A. Removal and Service Shelf Mounting... enw "FOO DOM 1500-00BT-00O FOS Table of Contents Excel Mounting: Optional Arm Mount B. Test Setup Tools Required. C. Installation Excel Mount and Stand Alone Modulus II Upgrade 7.3. Major Assembly Replacement... A. Control Board, Piggyback Watchdog Board and EPROM Replacement... Removal. Installation. B. Front Panel Board Replacement. Removal. C. Pressure Transducer Board Replacement Removal. Installation... D. EMC/Interface Board Replacement (Excel ‘Mount and Stand Alone) Removal. Installatio: E. EMC/Interface Board Replacement (Modulus I Upgrade). Removal Installation. eee F. Power Supply Board Replacement . 7-22 Removal. Installation. G. Primary Regulator Replacement... Removal. Installation... H. Pneumatic Manifold Assembly and EEPROM Replacement, : Removal. Installation. 8/Illustrated Parts List.. 1 8.1 General Information. 1 Current Parts or Historical Parts 1 Special Instructions. 1 Major Assemblies... 2 8.2 General Assemblies and Components... 8-4 Non-Autoclavable Bellows Assembly.. 8-4 Autoclavable Bellows Assembly : 8-6 Primary Regulator and Gas Inlet Valve 8-8 Pneumatic Manifold... : woe B10 Exhalation Valve..... 8-10 Free Breathing Valve... 8-10 "7800 DOM 1500-008T-000 S35 Table of Contents Other Pneumatic Manifold Parts Pneumatic Manifold Assembly.. Front Panel. ‘Transformer. Power Supply. ‘Transformer Mounting Rear Panel, Cables. Rear Panel, Pneumatic: Solenoids and Universal Board... Hoses TB1 - TB4 and TB13 with Universal Pressure Transducer Board 8-26 Tubes TBS - TB12 with Universal Pressure ‘Transducer Board. . Chassis with EMC. . : . Lower Control Module..... Piggyback Watchdog Board and 64K Control Board ... 64K Control Board Connections. EMC/Interface Board — Stand Alone. EMC/Interface Board — Excel Mount. : 8-40 Voltage Selector Label — Modulus II Upgrade. 8-42 Bottom Shroud, Battery and Software — Stand Alone. Bottom Shroud, are — Excel Mount Battery and Software — Modulus II Upgrade, Cover, Front Label and Knobs —. Stand Alone, Excel Mount, and Modulus IT Upgrade. Rear Labels — Stand Alone... Rear Labels — Excel Mount. Rear Label — Modulus II Upgrade Canadian Label and Fittings — Stand Alone, Excel Mount... EMC/Interface Board, Original — Modulus IT Upgrade 8.3 Historical Parts... Old Gas Inlet Valve Body Solenoids and Pressure Transducer Board (Original) 8-64 Hoses and Tubes, with Pressure Transducer Board (Original) z soerseereeees BBB 64K Control Board and Software, without Piggyback Watchdog Board... EMC/Interface Board, Original — Stand Alone EMC/Interface Board, Original — Excel Mount... 8.4 Mounting Mounted Directly to Excel , Top wea FE00 DOM TS00-00ET-000 FOE Table of Contents Excel Right Side, Top Shel Optional Arm. 8.5 Accessories... Sensor Related Parts.... Drive Gas tube: Mounting Options ev Gas Supply Hose (Excel Mount Only) .. Test Tools.. 8.6 Related Manuals........ 9/Schematics... Pneumatic Schematic. Filter, Breaker, Selector, Transformer (Universal)....... Filter, Breaker, Selector, Transformer (Original). Universal Power Supply Board. Power Supply Board (Original). 64K Control Board Piggyback Watchdog Board Front Panel Board... Universal Pressure Transducer Board.. Pressure Transducer Board (Original). EMC/Interface Board (International) EMC/Interface Board (Original) Excel/Ventilator Interface Cable (Excel Mount only).. Patient Interface Box and Internal Excel Machine (Excel Mount only). 100 DOM 1500 008T-000 FOS Table of Contents Notes: were 7E00 DOM 500-008-000 3-95 1/Introduction 1.1 Note, Important, Caution and Warning Throughout this manual, note, important, caution and warning have special meaning: Note: Is used to stress a point. Important: Is similar to a note but used for greater emphasis No matter which part of the manual you are using, always be familiar with the A\ CAUTIONS and A\ WARNINGS that appear. WARNINGS alert you to conditions or actions that may cause harm to humans. CAUTIONS alert you to conditions or actions that may result in damage to equipment. Pay special attention to the WARNINGS and CAUTIONS as they appear in this manual and on the equipment. Read the statements under the IMPORTANT heading; they describe what is expected of you to service, repair and maintain the ventilator. F800 DOM 15000081000 FOS 7 1/Introduction 1.2 Symbols We have also used—both in the manual and on the device itself—symbols to represent some common terms. No one product or manual has every symbol listed. Refer to this listing concerning symbols found on various products and manuals. \ ¢B++©? 100 CEO- +h a These symbols include: (on (power) Off (power) ‘Standby ‘Standby or preparatory state for a part of the equipment “ON” only for part of the equipment “OFF” only for part of the equipment Direct Current Alternating Current Protective earth ground Earth Ground Frame or chassis ground ‘Alarm silence button Equipotential Variability Variability in steps Plus, positive polarity Minus, negative polarity Lamp, lighting, illumination Movement in one direction Movement in both directions Lock Unlock 44°C Autoclavable @ Non-autociavable ‘Type B equipment ‘Type BF equipment Type CF equipment PBI @ Caution, 180 7000-0434 ZX AA serion,consun accompany- ing documents, IEC 601-1 Tris way up 4 Dangerous voltage D it © REF stock Number Output SN Serial Number Tz THO. DOM 1500 0BT-000 35 1/Introduction 1.3 Standard Service Procedures Operation and Service Manuals You must have, and be familiar with, the Operation and Maintenance manuals for this product. Study the Anesthesia System Operation and Maintenance manuals if you need further information about the operation of the system. You must determine where a problem is located before you can determine which manual to use. Refer to the various service manuals or accessory manuals if you require more information. Bellows Assembly This manual covers both the Autoclavable Bellows Assembly (ABA) and the non-autoclavable bellows assembly (non-ABA). ‘The Autoclavable Bellows Assembly is operator maintainable. For more information see the ventilator Operation and Maintenance manual, or the Autoclavable Bellows Assembly, Operation and Maintenance supplement. Stock Numbers for Replacement Parts Stock Numbers can be identified in the "8/Ilustrated Parts List" section of this manual. Parts can be obtained through Ohmeda offices/distributors. Ventilator tests Normal operational tests can be performed while the ventilator is installed in, or attached to, an anesthesia system. Calibration, troubleshooting or repair may require removing the ventilator from the anesthesia system. A\WARNING: Section “4/Tests and Calibration" must be performed whenever you remove a ventilator cover, to ensure that the ventilator is still operational and within specification. Failure to do so may result in patient injury. AXWARNING: You must perform section "3/Post-Service Checkout" for the entire anesthesia system before returning the system to clinical use. Failure to do so may result in patient injury. Z\WARNING: Do not perform testing or maintenance on medical equipment while they are being used on a patient; patient injury may result. F800 DOM T500-O0BT-000 335 7 1/Introduction 1.4 7800 Ventilator Configuration The 7800 Ventilator (hereafter called ventilator) is available in significantly different product packages. This manual is exclusively for ventilators with product group codes CAT and CBA. Check the product group code before you proceed. The Ventilator is composed of two basic units: + the Bellows Assembly which contains the bellows and bellows housing, and * the Control Module containing the control valves, processing circuits, controls, monitors and display screen. The Ventilator is available in three configuration: * Excel Mount, as an integrated ventilator in an Ohmeda Excel anesthesia system or * Stand-alone, for use with other anesthesia systems or * Modulus® II Upgrade, as an integrated ventilator in an Ohmeda Modulus II Anesthesia System. Differences in these configurations include: * How the control module and bellows assembly are mounted. * Connections between the control module, bellows assembly and anesthesia system. * Connection of the oxygen and volume sensors. |, registered trademark, BOC Health Care Inc 7 FEO DOM TS0000ET-O00 SOS 1/Introduction A. Excel Mount The control module can be mounted on an optional arm, or from a system shelf. On systems with flowmeters extending all the way to the top shelf, the control Module can hang, by a bracket, from the shelf to the right side of the flowmeters. On systems with the lower shelf extending over the flowmeters, the control module can hang directly from the shelf over the flowmeters. The bellows assembly can be mounted on top of the control module, on an optional arm, or directly to an Ohmeda GMS absorber (using an interface manifold). The anesthesia system ON/OFF switch, controls ventilator power up. Oxygen and volume sensor connections are located on the front left or right side of the Excel, below the table top. B. Stand-alone ‘The control module can be mounted on an optional arm, or stand. The bellows assembly can be mounted on. top of the control module, or directly to an Ohmeda GMS absorber (using an interface manifold). A power switch on the lower front panel, controls ventilator power up. Oxygen and volume sensors connect directly to the lower front panel of the control module Figure 1-1 Figure 1-2 Excel Mount Stand-alone E00 DOM T600-008T-000 FOS 7 1/Introduction C. Modulus II Upgrade The control module is mounted above the flowmeters inside the Modulus II. The bellows assembly can be mounted on an optional arm, or directly to an Ohmeda GMS absorber (using an interface manifold) The anesthesia system ON/OFF switch, controls ventilator power up. Oxygen and volume sensor connections are located on the front left side of the Modulus II, below the table top. Pad ° Figure 1-3 Modulus II Upgrade TS FOO DOM - 1500 0081-000 FOE 1/Introduction Product Group Code Ventilators with serial numbers starting with CAT were manufactured without a piggyback watchdog board and other EMC enhancements. Ventilators with serial numbers starting with CBA were manufactured with a piggyback watchdog board, Universal pressure transducer board, the newer EMC/Interface board (International), 4.xx or greater software, and other EMC enhancements. Piggyback Watchdog Board ‘The piggyback watchdog board provides enhanced monitoring of correct microcontroller operation. Note: The piggyback watchdog board is not installed on some units. Software Versions ‘This manual includes test and calibration procedures for versions 4.xx and ‘1.x software. EMC/Interface Board The EMC/Interface board attenuates electrical noise from electro-surgical units or other electrical noise generators in the operating room environment. This board is mounted behind the lower front panel (Excel Mount and stand- alone) or below the control module, inside the Modulus II Anesthesia system. The EMC/Interface board is available in two versions the original and international EMC/Interface boards. They are not directly interchangeable and require different cabling. Pressure Transducer Board A newer style "Universal" pressure transducer board is now available as a replacement for the original pressure transducer board. 700 DOM 1500 0081-000 F35 17 1/Introduction Notes: TE FEO DOM TS00-008T-000 FOE 2/Theory of Operation 2.1 Ventilator Overview The ventilator provides mechanical ventilation of patients during surgery. It is a microprocessor controlled pneumatic device. The ventilator consists of two major parts: + bellows assembly, which isolates the driving gas from the breathing gas * control module, which drives the bellows assembly; and monitors oxygen, pressures, and volumes. FEO DOM 1500-008T-000 S35 cay 2/Theory of Operation The Control Module Knobs and switches on the front of the control module are used to select operational parameters. A LCD (Liquid Crystal Display) shows current parameter information, alarms and error messages. The front panel also has an alarm silence button with red and yellow alarm lights LEDs (Light Emitting Diodes). The control module uses a compressed gas source (typically compressed oxygen) to pneumatically control patient ventilation. The gas is supplied by the anesthesia system from either attached cylinders or a pipeline gas supply. A microprocessor controls the operation of the control module. The microprocessor performs all of the timing, monitoring and sequencing involved in applying positive pressure to the bellows. ‘The main program memory is an EPROM (Erasable Programmable Read Only Memory). This memory retains its contents when the power is turned OFF. The EPROM holds the permanent preprogrammed application software package. The software revision number can be displayed in a special subroutine called the "Setup Page." Certain user set parameters are stored in an EEPROM (Electrically Erasable Programmable Read Only Memory) that can be altered under program control. ‘These include operator selected parameters that may vary between sites, such as speaker volume or altitude setting, and are not likely to be changed during a case. The EEPROM also contains the factory set calibration parameters for the flow control valve (part of the pneumatic manifold assembly). The calibration parameters cannot be programmed in the field. Ventilator data can be communicated to another device through an RS232 connection. w TEOO DOM 1500-00800 F35 2/Theory of Operation The Bellows Assembly The drive gas output of the control module is used to impress breathing gas on the patient. The drive gas is on the outside of the bellows and is isolated from the breathing gas on the inside. There is no direct connection between the two gas volumes. The ventilator moves breathing gas to the patient by applying positive pressure on the breathing circuit. Exhalation occurs when the ventilator releases the positive drive gas pressure to atmosphere. The ventilator drive gas output is connected to the bellows assembly by a flexible hose. A small diameter pressure sensing tube connects the patient breathing circuit to the control module which monitors pressure in the breathing circuit. The operator can select an adjustable inspiratory pressure limit which limits the inspiration phase of ventilation if excess pressure is detected. An independent pressure relief valve is located inside the bellows. If excess gas accumulates during exhalation, this valve will open and exhaust the excess breathing gas. E00 DOM 1S00-008T 000 355 3s 2/Theory of Operation 2.2 Pneumatic Description mu Exhalation Supply Gas ‘Transducer ‘Limit Switch Figure 2-1 Block Diagram Pneumatic Circuit Pay TE00 DOM T500-008T-000 F3E 2/Theory of Operation A. Gas Inlet Valve The gas inlet valve switches the supply gas entering the control module. The gas inlet valve and inlet solenoid together form a valve that is normally OFF. The supply gas is turned ON by the microprocessor at power up. If the electrical power ever fails, the gas inlet valve shuts OFF. Inside the gas inlet valve is a shuttle (spoppet). The shuttle has a small control stop on one end which blocks or allows the flow of supply gas to the primary regulator. When the inlet solenoid is OFF, a pressure differential holds the shuttle in the closed position. The inlet solenoid must be activated (have current flow) in order for the gas inlet valve to allow supply gas into the control module. When the inlet solenoid is turned ON, the energized coil attracts a plug that blocks the inlet orifice. At the same time the exhaust orifice is opened,. the compressed gas at the large side of the shuttle is vented through the inlet solenoid. The pressure on the small side of the shuttle moves it, opening the gas inlet valve. Inlet Solenoid Inlet Solenoid SOL2 (OFF) SOL2 (ON) Supply Gas, Supply Gas Figure 2-2 Inlet Solenoid and Gas Inlet Valve, OFF and ON "TEO0 DOM = T500-008T-000 5-35 2s 2/Theory of Operation B. Pressure Regulation The ventilator has a primary regulator and a secondary regulator. The primary regulator is mounted next to the gas inlet valve. Supply gas enters the primary regulator directly from the gas inlet valve. The primary regulator output connects to the pneumatic manifold assembly which contains the flow control valve. The output of the primary regulator also goes to a secondary regulator that further reduces the pressure. The output of the secondary regulator is used to inflate the exhalation valve. Bleed Secondary Secondary Secondary Regulator Output =4—@€ as imtet vaive Primary Regulator @ <4— supply Gas mput Output Primary Regulator rite Figure 2-3 Primary Regulator and Secondary Regulator a "FOO DOM T500-O08T 000 395 2/Theory of Operation C. Flow Control Valve The drive for inspiration is an increase in pressure applied to the breathing circuit. Ventilation drive gas flow is supplied by the flow control valve. The precise amount and rate of inspiration is accurately controlled by the microprocessor through a digital to analog converter. The microprocessor proportionally changes the drive gas flow by changing the current applied to the flow control valve. If the power is removed the flow control valve shuts OFF. Exhalation Valve (Inflated) Flow Control Valve Gas In High Pressure Sensor Figure 2-4 Pneumatic Manifold Assembly Inspiration The flow control valve releases positive pressure into the drive chamber. As gas enters, the drive gas pressure builds up in the drive chamber, through the flexible hose, and increases the pressure in the bellows assembly. During the inspiratory phase of ventilation the drive gas increases the patient circuit pressure and, in combination with the duration, determines the tidal volume. "F800 DOM T500-D0BT- 000 335 aT 2/Theory of Operation D. Exhalation Valve The pneumatic manifold assembly has an internal exhaust chamber. The exhaust chamber is open to atmosphere through the back of the control module. Note the louvers above the drive gas output on the rear panel. Exhaust gas from the two solenoids and the secondary regulator, is connected to the exhaust chamber and relieve directly to the atmosphere. During the exhalation phase, the exhalation valve is deflated and drive gas pressure is released to the atmosphere through the exhaust chamber. Exhalation Valve Flow Control / wouvers ‘Valve (Closed) Exhaust Gas In 4 Free Breathing valve Figure 2-5 Pneumatic Manifold Assembly Exhalation ‘The drive chamber and exhaust chamber are separated by the exhalation valve. The exhalation valve inflates, like a balloon, to seal off the opening. oe "7800 DOM = 1500-008T-000 5-95 2/Theory of Operation Exhaust Secondary Regulator Output (Low Pressure) Exhalation Solenoid SOL1 (ON) Bleed Regulated —> [Hil Pressure ‘Secondary Regulator | Exhalation Valve Figure 2-6 Exhalation Valve Inflating During inspiration, positive pressure is held in the drive chamber by inflating the exhalation valve. Positive pressure builds in the drive chamber, drive gas hose and the outside chamber of the bellows assembly. The flow control valve allows gas flow for the desired inspiratory time. Approaching the end of inspiration the flow control valve is turned OFF. If inspiratory pause (Typ) is ON, the exhalation valve will remain inflated for an additional 25% of the set inspiratory time. The exhalation valve is deflated at the end of inspiration. This relieves the positive pressure in the drive chamber and allows the drive gas in the bellows assembly to be vented through the exhaust chamber to the atmosphere. FEO DOM T500- 0087-000 535 2 2/Theory of Operation Exhaust Exhalation Solenoid SOL1 (OFF) Bleed Regulated —>[] Pressure Secondary Regulator Figure 2-7 Exhalation Valve Deflating E. Bellows The bellows isolates the drive gas from the breathing gas supplied by the anesthesia system. At no time does the drive gas enter the patient breathing circuit. During the inspiratory phase, the control module delivers drive gas into the area between the bellows and the bellows housing. As the volume of gas increases, pressure is exerted on the bellows which compresses. The bellows in turn exerts pressure on the patient breathing circuit and the patient's lungs, During the exhalation phase, the drive circuit pressure is vented to the atmosphere. This reduction in pressure allows gas to flow from the patient breathing circuit into the bellows. The bellows rises within the bellows housing F. Pressure Relief Valve ‘The pressure relief valve is located within the bellows. This valve remains closed during inspiration. When the bellows cannot extend any further during exhalation, the pressure relief valve opens and the excess gas is vented through the exhaust tube. This will happen when the pressure in the patient circuit during exhalation exceeds the vented driving gas circuit pressure by approximately 2.5 cm H30. at) TEO0 DOM T500-008T-000 595 2/Theory of Operation G. Free Breathing The free breathing valve acts as a check valve. Normally the pressure within the drive chamber and corresponding bellows and breathing circuit is controlled by the ventilator. If the patient attempts to inhale, a sudden drop in breathing circuit pressure occurs. If the drive gas flow is less than the demand, pressure within the drive chamber will drop, the free breathing valve will open making up the additional volume with ambient air. This allows the patient to breathe spontaneously, Figure 2-8 Free Breathing Valve "F800 DOM = 1500-0081 000 595 wT 2/Theory of Operation H. Pressure Sensing The output of the primary regulator is monitored by a high pressure transducer. If the pressure is greater than about 207 kPa (30 psi), the microprocessor will not allow ventilation and an error message is displayed. The pressure within the drive chamber is monitored by a pressure switch. This circuit is independent of the microprocessor to maintain operational integrity in the event of a microprocessor failure. If excessive pressure (approximately 105 cm H20) is detected, the switch closes and causes the exhalation valve to deflate relieving the drive circuit pressure. /—— Low Pressure Cy ‘Transducer ED Patient Airway Pressure IN Drive Circuit Pressure OUT Gas IN High Pressure High Pressure ‘Transducer Limit Switch Figure 2-9 Pressure Sensing A pressure sensing point is located in the breathing circuit. This pressure is fed back to the control module though a clear pressure sensing tube. The tube is connected to the low pressure transducer, located on the pressure transducer board. This pressure monitor allows the microprocessor to respond to pressure in the breathing circuit. Tz "FEO DOM T500- 0087-000 53 2/Theory of Operation I. Filtering A replaceable five (5) micron particulate filter is located between the primary regulator and secondary regulator. A permanent coarse (150 mesh) screen filter is located where the gas enters the pneumatic manifold assembly. 5 micron Filter Figure 2-10 Filter "F800 DOM - T500- 0087-000 535 war 2/Theory of Operation 2.3 Electronic Descriptions Exhalation Valve Switch Solenoid Solenoid W2pia H6spin Jo2pim JOSpin JO 10pin Control Board eirurbe EPROM Watchdogs _—_I Battery EMC/Interface Board INPUT SENSOR ON// Standby INPUT. Switch Stand-Alone Only Figure 2-11 Block Diagram Electrical zt "700 DOM = T500-008T-000 535 2/Theory of Operation Notation Within this Text Unless otherwise noted, all voltages are positive with respect to signal and supply common (DGND and AGND). A “/" indicates that for this signal, active (true) is at a logic level of zero (0). Some examples are: /CS2, /RD, or /WR. This is often referred to as a "negative logic" or “active low" signal. All voltages are designated as direct current "V dc" or alternating current "Vac." Voltages are also designated as positive "+" or negative "minus (-)." Some examples are: "+ 4.37 V de," or "minus (-) 4.37 V de." Tolerances are expressed with an additional number: "5.25 40.01 V de." Current values are designated as Ampere "A dc", milliampere "mA dc" or microampere as " A dc." Component Designations Component numbers are separated from pin numbers by a "-." Like this: "U124-2" or “J2-15." Additional pins are separated by a comma "U8-2,3" or "J10-7,8. “Typical Notation Part c178 Capacitor cR124 Diode F2 Fuse FL1 Filter Jt, 316 Connector jumper, jack or plug K102 Relay L103 Inductor Pl Connector jack or plug R102 Resistor fixed or adjustable swio1 Switch u124 Integrated circuit "7800 DOM = T500-O08T-000 5-95 7s 2/Theory of Operation A. Power Cord ‘The line cord is permanently attached to the control module. B. Filter, Breaker, Selector, Transformer The power cord connects directly to the electromagnetic interference line filter, FLTR. The device filters interference going to and coming from the control module, ‘The output of the filter goes to a 0.5 A double pole circuit breaker, BKR. Excess line current, or neutral current, can cause this circuit breaker to open, disconnecting both inputs. The transformer windings are selected by a multiple pole voltage selector switch (VSC). The combinations of windings provide for different selectable primary voltages (100, 120, 220, 240 V ac). ‘The transformer has internal thermal protection and will open the primary winding if the temperature reaches 150° C. The secondary of the transformer steps down to a center tapped 32 V ac. C. Power Supply Board (Original) The power supply board converts an ac or de input to +5 V, 3 Adc using a step-down switching regulator configuration. CR1, CR2 and J1-1 form a full-wave center-tap rectifier circuit which is filtered by C1. Alternatively, a de input voltage (8.5 to 35 V dc) can be input at J1-4, U1 converts the dc input by chopping the voltage with an internal transistor switch. The resultant square wave is filtered through a low-pass filter, T1 and C2. R1 programs the output voltage of the regulator. U2 is for over-voltage protection in the event of regulator failure. we F800 DOM - T500-D08T-000 335 2/Theory of Operation D. Power Supply Board (Universal) ‘The power supply board converts an ac or dc input to +5 V, 3 Adc using a step-down switching regulator configuration. ‘The ac input is supplied by a transformer secondary with a center tap connection. ‘The input voltage range is from 28.8 V ac (center tapped) minimum, to 48.0 V ac (center tapped) maximum, for a transformer rated at 42 VA. Fuses F1, F2, and F3 provide fault protection in the event of a component failure on the power supply board. U1 is an adjustable output, 3A de step-down switching voltage regulator. The combination of resistors R6 and R8 and potentiometer R7 provide a typical output voltage adjustment range of from +4.3 to +5.8 V de. U2 is a power supply supervisory circuit, used to monitor over and under voltage fault conditions. When a dc output voltage exceeding +6.17 V de (typical) is detected for a period exceeding 125 microseconds (typical), U2-1 will go to logic 1, and cause crowbar SCR CRS to conduct. Once SCR CRS is turned ON, it will remain ON as long as input power is applied to connector Ji; the voltage at J2-1 and J2-2 will be reduced to the forward drop of CR5 (0.8 V dc typical). When an unregulated voltage exceeding +36.6 V de (typical) is detected for a period exceeding 1.25 milliseconds (typical), the open collector output U2-6 will turn OFF, and be pulled to a logic 1 by R11. Resistors R3 and R4 provide a high impedance path from dc ground, to chassis ground. Capacitor C6, provides a high frequency path from dc ground to chassis ground, for electrical noise and electrostatic discharge. Chassis ground is tied to this circuit board through the heat sink on U1. TeO0 DOM T500-O0ET-000 335 EAT 2/Theory of Operation E. Two Layer Control Board 1. Power Source Selection [Sheet 3 of schematic, section 9] The + 5 V de power supply voltage is connected to the control board via J3-1,2 (+) and J3-3,4 (-). Fuse F101 limits current to 4 A de. 2. Battery [Sheet 3] ‘The 7800 Ventilator backup battery is connected to J2-1 (+) and J2-3(-). J2-2 is used for 7800 model identification. Headers J14 and J15 (jumpered for 7810 and 7850 only) provide the capability of using the ventilator without an internal battery. 3. System Power Up Relay [Sheet 3] System power up relay K102 switches the VCC power source selected by K101 to the rest of the ventilator system. K102 can be energized by shorting jumper J4 on the control board or by connecting REMOTE+ to REMOTE: with a remotely located switch. Power is routed to the flow control valve circuits, gas inlet valve circuits, exhalation valve circuits and the de-dc converters. 4. Plus (+) 7.5 V de and Minus (-) 7.5 V de [Sheet 3] U116 is a step-up switching-regulator that generates plus (+) 7.5 V de. U110 is a inverting switching-regulator that generates minus (-) 7.5 + 0.60 V de. Both voltages are supplied to the pressure transducer board through connector J6. 5. E.L. Panel Driver [Sheet 3] L108 is a de-to-ac converter which develops 80 +20 V ac at 700 +100 Hz with an electro-luminescent panel connected to its output. R114 provides a means for adjusting the output voltage to the EL panel, affecting its brightness. J11 is for de-energizing the EL panel. ae "7800 DOM - T500-008T-000 5-35 2/Theory of Operation 6. Power Up RESET and Program Flow Watchdog Timer [Sheet 1] ‘The watchdog timer circuit is based upon a dual retriggerable monostable multivibrater, U122. During power up, the clear inputs are held low for approximately 0.3 seconds. Then a 0.5 sec low pulse is generated at the output (U122-12) which becomes the power up reset pulse (RST). U122 monitors the power supply voltage level and forces a system reset if a low VCC voltage error or out of limit condition is detected. The voltage trip point is set at 4.5 V de maximum (4.37 V de typical). After power up reset, the microcontroller (U117-8 ) will output a 50 Hz, 50% duty cycle square wave (WDOG). If the WDOG pulses should stop, a 0.5 second RST pulse is delivered by the timer every 1.5 seconds. The RST pulses will continue as long as there is no WDOG pulse and the system remains powered. 7. 16x 16 EEPROM [Sheet 1] U114 is a 16 register by 16-bit EEPROM. All data transfer to and from the device is done serially. 8. Microcontroller Oscillator [Sheet 1] ¥101, C57-C60, and the oscillator circuit in U117 (microcontroller) form a 12 MHz oscillator which provides the master clock for the 80C31 microcontroller. 9. RS-232 Interface [Sheet 1] U116 is a dual RS-232 receiver/transmitter. It contains two voltage converters which generate +10 V de and (minus) -10 V dc from +5 V de. U116 contains four level translators. Two of the level translators are RS-232 transmitters and convert T'TL/CMOS input levels into plus (+) 9 V de and minus (-) 9 V de RS-232 outputs. The other two level translators are RS-232 receivers which convert RS-232 inputs to +5 V de TTL/CMOS output levels. A single transmitter and receiver are used. The output of the transmitter and the input of the receiver are connected to J5. TEO0 DOM T500-008T-000 335 zs

You might also like