CALIBRATION FUNCTION Do not select this function: the machine has already been calibrated in Tecnotest. To check calibration using a calibrated load cell select manual mode without ramp. {n case it is necessary to do a new machine calibration read the ‘calibration paragraph’ of Eurotronic manual use. The Eurotronic manual use is attached to the end of this instructions. EUROTRONIC CALIBRATION 7 Example of a 2000kN compression machine [A S57 1234 = place on the machine the reference load cell (calibrated dynamometer) = tum off and then turn on eurotronic = check calibration in manual mode: only if errors are over 1% perform a new calibration = select calibration by using F2-F3 and confirm by F4 = apassword is requested: press E, input 1234, press E, confirm by F4 = select channel you must calibrate now you are inside calibration page: ~ press E: the field relevant to min is highlighted, input 0, confirm by E ~ the field relevant to max is highlighted, input 20000, confirm by ~ the field relevant to KN is highlighted: confirm by E, press rightleft arrows Keys to change KN in mm or mm in kN (select mm only to calibrate displacement transducer) ~ for compression machine confirm kN by E = _ the field relevant to decimals is highlighted: input 1 and confirm by E (1 decimal point so that the display will show 2000. OKN at full scale) = _ the field relevant to bits near ‘P 0.0" is highlighted: do not press E !! . Turn on compression machine, when load on load cell is OkN press F2 on eurotronic so that you can memorize the bits relevant to first point of calibration (OkN) = allttle arrow on display will appear on.the line of ‘Pt 1 +200.0 .....: stress load cell at 200kN ‘and when you read 200kN on load cell press F2 to themorize the second point of calibration. In Practice: quickly increase load on the load cell from OkN to 160-170KN then slow down the nearer the 200KN objective is reached and, once reached, press F2 to memorise. The more slowly calibration points are crossed, the less influence the reaction time of operator will have = allttle arrow on display will appear on the line of "Pt 2 +400.0 ...... stress load cell at 400kN and when you read 400kN on load cell press F2 to memorize the second point of calibration = alittle arrow on display will appear on the line of ‘Pt 3 +600.0 ...... stress load cell at 600kN and when you read 600kN on load cell press F2 to memorize the third point of calibration = alittle arrow on display will appear on the line of 'Pt4 +800.0 ... stress load cell at 800kN and when you read 800kN on load cell press F2 to memorize the 4th point of calibration = allttle arrow on display will appear on the line of ‘Pt § +1000.0 ....”: stress load cell at 1000kN and when you read 1000kN on load cell press F2 to memorize the 5th point of calibration = tepeat this procedure until aa litle arrow on display appear on the line of "Pt 10 +2000.0 stress load cell at 2000kN and when you read 2000kN on load cell press F2 to memorize the last Point of calibration - discharge pressure, wait 10 seconds, press ‘F3'key to save calibration = press F1 to exit = select manual mode and check calibration « KF 200_300-CE 12-02- 2013 REV 1 ENG.DOC Page 30 of 37

You might also like