You are on page 1of 4

Supplement to the Notifier SLC Manual

51253 Revision U2
dated 7/30/2014

A3
Document LS10055-151NF-E
12/04/2014 Rev:
P/N LS10055-151NF-E:A3 ECN 14-0727
Software Downloads
In order to supply the latest features and functionality in fire alarm and life safety technology to our customers, we make
frequent upgrades to the embedded software in our products. To ensure that you are installing and programming the latest
features, we strongly recommend that you download the most current version of software for each product prior to
commissioning any system. Contact Technical Support with any questions about software and the appropriate version for
a specific application.

Documentation Feedback
Your feedback helps us keep our documentation up-to-date and accurate. If you have any comments or suggestions about
our online Help or printed manuals, you can email us.
Please include the following information:
• Product name and version number (if applicable)
• Printed manual or online Help
• Topic Title (for online Help)
• Page number (for printed manual)
• Brief description of content you think should be improved or corrected
• Your suggestion for how to correct/improve documentation
Send email messages to:
FireSystems.TechPubs@honeywell.com
Please note this email address is for documentation feedback only. If you have any technical issues, please contact
Technical Services.

2 Supplement to the Notifier SLC Manual P/N LS10055-151NF-E:A3 12/04/2014


1.3 Related Documentation
Two new documents are added to the list shown in Table 1.1 of 51253:U2:
SLC Loop Devices Document Number

B200S-LF Intelligent Addressable Low-Frequency Sounder Base Installation document I56-4151

B200SR-LF Intelligent Low-Frequency Sounder Base Installation document I56-4152

Table 1.1 Reference Documentation

1.6.7 Plug-in Detector Bases


New devices of this type are added to the list in Section 1.6.3 of 51253:U2:
• Sounder Base - Model B200S-LF is a low-frequency version of the B200S, and B200SR-LF is a low-frequency
version of the B200SR.

10.1.1 Intelligent Detector Bases


New devices of this type are added to the list in Section 10.1.1 of 51253:U2:
The B501 and B210LP Detector Bases, the B224BI Isolator Base, the B224RB plug-in Relay Detector Base, and the
B501BH/B501BH-2, B501BHT/B501BHT-2, B200S/B200S-LF, and B200SR/B200SR-LF Sounder Base provide the
connection between the SLC and a variety of intelligent detectors. Use the B710HD Detector Base with all HARSH™
detectors. See Sections 10.2 – 10.5.

10.5 Wiring a Sounder Base


In Section 10.5 of 51253:U2, existing diagram for B200S should be used for B200S-LF, and existing diagram for B200SR
should be used for B200SR-LF.
Figure 10.5 shows typical wiring of the B200S and B200S-LF Sounder Bases.
Note: The “grid” pattern on the B200S/
B200S-LF has been removed for
illustration purposes only.
To next device
on SLC

Optional Remote
LED Annunciator
RA100Z/400Z
slc-b200srwire2014.wmf

UL-Listed 24V
Power Supply with
System Sensor
sync output

SLC

Figure 10.5 Wiring of the B200S/B200S-LF Sounder Base

Supplement to the Notifier SLC Manual P/N LS10055-151NF-E:A3 12/04/2014 3


Figure 10.6 shows typical wiring of the B200SR and B200SR-LF Sounder Bases.
Note: The “grid” pattern on the
B200SR/B200SR-LF has been
To next device removed for illustration purposes only.
on SLC

Optional Sounder
Interconnect

slc-b200srwire2014.wmf
UL-Listed 24V
Power Supply with
System Sensor
sync output

SLC
Figure 10.6 Wiring of the B200SR/B200SR-LF Sounder Base

NOTE: For more detailed wiring on sounder bases, refer to the device’s installation instructions.

Appendix E: Canadian Versions of SLC Devices


Because the low-frequency bases are designed for a UL requirement; there is no ULC-listed version of B200S-LF or
B200SR-LF.

4 Supplement to the Notifier SLC Manual P/N LS10055-151NF-E:A3 12/04/2014

You might also like