Fault locating with the aid of an LPU display Page 1 of 35

FAULT LOCATING INSTRUCTIONS


1/1545-APD 102 01 Uen G3

Fault locating with the aid of an LPU display

Contents
1 General
1.1 Start and restart phases
1.2 LPU display

2 Display codes
2.1 The display codes 10-116
2.2 The display codes 5xx-90aa

3 Sequence diagrams for correct processes


3.1 Sequence diagram for initial load of I/O LIM
3.2 Sequence diagram for initial load of non-I/O LIM
3.3 Sequence diagram for reload of I/O LIM
3.4 Sequence diagram for reload of non-I/O LIM
3.5 Sequence diagram for initial load of standby side
3.6 Sequence diagram for reload of standby side

1 General
The display board is to be used at fault locating when the initial start or restart of the exchange has
failed, see Figure 1-1.

The display board is plugged in the front of the LPU board, see Figure 1-2.

If no display code is obtained (blank display) after the restart button has been pushed, replace the LPU
board.

Next follows a short description of what is dealt with in each section in the document.

Section: Display codes

• All display codes are there enumerated in number sequence. For every display code the
meaning and any applicable measures for fault situations are stated.

Section: Sequence diagrams for correct processes

http://localhost:9032/alexserv?ID=18470&DB=en_lzn7480005_2_r7a.alx&FN=1_1545-... 21/10/2021
Fault locating with the aid of an LPU display Page 2 of 35

• This section contains 6 sequence diagrams for correct loading processes. For each sequence
diagram a description is given of the order in which the applicable display codes are presented
on the LPU display.

The sequence diagrams for initial loading contain the display codes that are generated by the
different commands used in the loading process.

The six sequence diagrams describe the following loading processes:

◦ Initial load of I/O LIM


◦ Initial load of non -I/O LIM
◦ Reload of I/O LIM
◦ Reload of non -I/O LIM
◦ Initial load of standby side
◦ Reload of standby side

Note Some display codes are sometimes displayed during such a short time that they may not be
seen.

1.1 Start and restart phases


• Initial start phase 1:

Phase, where program units initiate reload and dynamic data and request time measurement.
Device boards are to be blocked.

• Restart phase 1:

Phase, where program units initiate dynamic data and request time measurement.
Device boards are to be blocked.

• Regional restart phase 1:

Phase, where program units initiate dynamic data, except from those which indicate external
linkage, and are established during phase 1.5. Time measurement is requested.

• Phase 1.3:

Phase where program units shall send and receive information about static data. The data shall
only be changed when reconfiguration is made e.g. add of LIM, or exchange of program unit.
The data shall be reload marked.

• Phase 1.5:

Phase where program units shall provide dynamic data necessary for execution.

• Initial start phase 2:

Phase, where routine supervision is started. Program units must be ready for traffic.

http://localhost:9032/alexserv?ID=18470&DB=en_lzn7480005_2_r7a.alx&FN=1_1545-... 21/10/2021
Fault locating with the aid of an LPU display Page 3 of 35

• Restart phase 2:

Phase, where routine supervision and the activation of device boards is to be started.

• Start after data reload:

Phase, where program units can check the connections between reload data and dynamic data.

1.2 LPU display

Figure 1-1. The LPU display board

A toggle switch is placed to the upper left on previous boards. This switch has no function. It can be
set in any position.

http://localhost:9032/alexserv?ID=18470&DB=en_lzn7480005_2_r7a.alx&FN=1_1545-... 21/10/2021
Fault locating with the aid of an LPU display Page 4 of 35

Figure 1-2. The connection of the LPU display in the LPU board front

2 Display codes
2.1 The display codes 10-116

LOAD INFORMATION

10 I/O board is found. PLF activates the I/O board and searches for load directories.
15 NIU/NIU2 board is in service mode.

http://localhost:9032/alexserv?ID=18470&DB=en_lzn7480005_2_r7a.alx&FN=1_1545-... 21/10/2021
Fault locating with the aid of an LPU display Page 5 of 35

The service mode is initiated or ended by NIUX commands, and this function is used to update
the loading volume from a remote maintenance centre. When the service mode is ended, PLF will
start loading the system. The service mode on an NIU/NIU2 does not make any effect on a
running system.
20 Waiting for contact

• Executing side, non-I/O LIM:

PLF initiates a signalling path and waits for contact with I/O LIM.

• Standby side:

PLF initiates a signalling path and waits for contact with the executing side.

• Executing side, I/O LIM:

No I/O board is found.


30 Action described in code 20 has been completed successfully.

• Executing side, non-I/O LIM:

The supervising program in I/O LIM has reached contact with the LIM.

• Standby side:

The supervising program in the executing side has reached contact with the standby side.
40 A load order has been obtained.
50 The LIM disposition table is being loaded.
51 The LIM disposition table has been successfully loaded.
6x Program code and data files are being loaded.

• Initial load:

Program units from external backup are being loaded.

• Load of standby side:

Program units from the memory of executing side are being loaded. DS data are also being
loaded.
70 Local backup is being updated from external backup.
71 Local backup has been successfully updated.

8x Reload:
Program code from external backup are being loaded.
90 Create logical memory

• Initial load:

http://localhost:9032/alexserv?ID=18470&DB=en_lzn7480005_2_r7a.alx&FN=1_1545-... 21/10/2021
Fault locating with the aid of an LPU display Page 6 of 35

Memory space for DS data is being reserved and address references are being created for
loaded program units.

• Reload:

Memory space for DS data is being reserved, data from local backup are being loaded and
address references are being created for loaded program units.

• Load of standby side

Address references are being created for loaded program units.


91 Actions described at display code 90 has been successfully completed.
92 The loading program (PLF) has requested start of the LIM after loading.
93 The loading program (PLF) has requested start of the LIM after main failure.
94 The loading program (PLF) has requested start of the LIM after unexpected watchdog reset.
95 The loading program (PLF) has requested start of the LIM after two pushes on the reset button on
the LPU board.
Note x is incremented one step to maximum 9, then starts from 0 again, repeating itself while the
tens digit remains fixed.

Increment takes place every second if any program unit has been successfully loaded during
this time.

EXAMPLE

The display shows code 83.

The tens digit (8) display that reload of program code from external backup is in progress.

The units digit is incremented every second if any program unit has been successfully loaded during
this time.

START AND RESTART INFORMATION

99 LIM has received a start request in some phase.


100 Initial start phase 1 is ready.
101 Phase 1.5 is ready.
102 Restart phase 1 is ready.
103 Initial start phase 2 is ready.
104 Restart phase 2 is ready.
105 Phase 1.3 is ready.
106 Regional restart phase 1 is ready.
11x

http://localhost:9032/alexserv?ID=18470&DB=en_lzn7480005_2_r7a.alx&FN=1_1545-... 21/10/2021
Fault locating with the aid of an LPU display Page 7 of 35

Start after data reload is ready. To be able to keep information about the last restart x will not be
overwritten by a start after data reload.

2.2 The display codes 5xx-90aa

http://localhost:9032/alexserv?ID=18470&DB=en_lzn7480005_2_r7a.alx&FN=1_1545-... 21/10/2021
Fault locating with the aid of an LPU display Page 8 of 35

http://localhost:9032/alexserv?ID=18470&DB=en_lzn7480005_2_r7a.alx&FN=1_1545-... 21/10/2021
Fault locating with the aid of an LPU display Page 9 of 35

http://localhost:9032/alexserv?ID=18470&DB=en_lzn7480005_2_r7a.alx&FN=1_1545-... 21/10/2021
Fault locating with the aid of an LPU display Page 10 of 35

http://localhost:9032/alexserv?ID=18470&DB=en_lzn7480005_2_r7a.alx&FN=1_1545-... 21/10/2021
Fault locating with the aid of an LPU display Page 11 of 35

http://localhost:9032/alexserv?ID=18470&DB=en_lzn7480005_2_r7a.alx&FN=1_1545-... 21/10/2021
Fault locating with the aid of an LPU display Page 12 of 35

http://localhost:9032/alexserv?ID=18470&DB=en_lzn7480005_2_r7a.alx&FN=1_1545-... 21/10/2021
Fault locating with the aid of an LPU display Page 13 of 35

http://localhost:9032/alexserv?ID=18470&DB=en_lzn7480005_2_r7a.alx&FN=1_1545-... 21/10/2021
Fault locating with the aid of an LPU display Page 14 of 35

http://localhost:9032/alexserv?ID=18470&DB=en_lzn7480005_2_r7a.alx&FN=1_1545-... 21/10/2021
Fault locating with the aid of an LPU display Page 15 of 35

http://localhost:9032/alexserv?ID=18470&DB=en_lzn7480005_2_r7a.alx&FN=1_1545-... 21/10/2021
Fault locating with the aid of an LPU display Page 16 of 35

http://localhost:9032/alexserv?ID=18470&DB=en_lzn7480005_2_r7a.alx&FN=1_1545-... 21/10/2021
Fault locating with the aid of an LPU display Page 17 of 35

http://localhost:9032/alexserv?ID=18470&DB=en_lzn7480005_2_r7a.alx&FN=1_1545-... 21/10/2021
Fault locating with the aid of an LPU display Page 18 of 35

http://localhost:9032/alexserv?ID=18470&DB=en_lzn7480005_2_r7a.alx&FN=1_1545-... 21/10/2021
Fault locating with the aid of an LPU display Page 19 of 35

http://localhost:9032/alexserv?ID=18470&DB=en_lzn7480005_2_r7a.alx&FN=1_1545-... 21/10/2021
Fault locating with the aid of an LPU display Page 20 of 35

Note Display codes (4-digits) which are described with two introductory digits + 2 arbitrary
digits, designated with xx or aa, gets their main meaning from the two introductory digits.

The meaning of the two arbitrary (subcode) digits (xx) can be obtained from the display codes with 2
digits. If the previous written display was a subcode it is kept.

If an additional information (aa) is obtained, the previous code is overwritten.

http://localhost:9032/alexserv?ID=18470&DB=en_lzn7480005_2_r7a.alx&FN=1_1545-... 21/10/2021
Fault locating with the aid of an LPU display Page 21 of 35

EXAMPLE

The display shows code 9016. Memory test is in progress. The memory size is 16 Mbyte.

The display shows code 1009. Memory fault has been detected. The fault is in a memory position
between 9 and 10 Mbyte.

The display shows code 1265. The two introductory digits (12) indicate buffer transfer error. The
digits (65) indicate, during load of program code from external backup, that received data block
exceeds maximum block size.

3 Sequence diagrams for correct processes


3.1 Sequence diagram for initial load of I/O LIM

http://localhost:9032/alexserv?ID=18470&DB=en_lzn7480005_2_r7a.alx&FN=1_1545-... 21/10/2021
Fault locating with the aid of an LPU display Page 22 of 35

http://localhost:9032/alexserv?ID=18470&DB=en_lzn7480005_2_r7a.alx&FN=1_1545-... 21/10/2021
Fault locating with the aid of an LPU display Page 23 of 35

http://localhost:9032/alexserv?ID=18470&DB=en_lzn7480005_2_r7a.alx&FN=1_1545-... 21/10/2021
Fault locating with the aid of an LPU display Page 24 of 35

3.2 Sequence diagram for initial load of non-I/O LIM

http://localhost:9032/alexserv?ID=18470&DB=en_lzn7480005_2_r7a.alx&FN=1_1545-... 21/10/2021
Fault locating with the aid of an LPU display Page 25 of 35

http://localhost:9032/alexserv?ID=18470&DB=en_lzn7480005_2_r7a.alx&FN=1_1545-... 21/10/2021
Fault locating with the aid of an LPU display Page 26 of 35

http://localhost:9032/alexserv?ID=18470&DB=en_lzn7480005_2_r7a.alx&FN=1_1545-... 21/10/2021
Fault locating with the aid of an LPU display Page 27 of 35

3.3 Sequence diagram for reload of I/O LIM

http://localhost:9032/alexserv?ID=18470&DB=en_lzn7480005_2_r7a.alx&FN=1_1545-... 21/10/2021
Fault locating with the aid of an LPU display Page 28 of 35

http://localhost:9032/alexserv?ID=18470&DB=en_lzn7480005_2_r7a.alx&FN=1_1545-... 21/10/2021
Fault locating with the aid of an LPU display Page 29 of 35

3.4 Sequence diagram for reload of non-I/O LIM

http://localhost:9032/alexserv?ID=18470&DB=en_lzn7480005_2_r7a.alx&FN=1_1545-... 21/10/2021
Fault locating with the aid of an LPU display Page 30 of 35

http://localhost:9032/alexserv?ID=18470&DB=en_lzn7480005_2_r7a.alx&FN=1_1545-... 21/10/2021
Fault locating with the aid of an LPU display Page 31 of 35

3.5 Sequence diagram for initial load of standby side

http://localhost:9032/alexserv?ID=18470&DB=en_lzn7480005_2_r7a.alx&FN=1_1545-... 21/10/2021
Fault locating with the aid of an LPU display Page 32 of 35

http://localhost:9032/alexserv?ID=18470&DB=en_lzn7480005_2_r7a.alx&FN=1_1545-... 21/10/2021
Fault locating with the aid of an LPU display Page 33 of 35

3.6 Sequence diagram for reload of standby side

http://localhost:9032/alexserv?ID=18470&DB=en_lzn7480005_2_r7a.alx&FN=1_1545-... 21/10/2021
Fault locating with the aid of an LPU display Page 34 of 35

http://localhost:9032/alexserv?ID=18470&DB=en_lzn7480005_2_r7a.alx&FN=1_1545-... 21/10/2021
Fault locating with the aid of an LPU display Page 35 of 35

Note x is incremented one step to maximum 9, then starts from 0 again, repeating itself while the
tens digit remains fixed.

Increment takes place every second if any program unit has been successfully loaded during
this time.

EXAMPLE

The display shows code 9016. Memory test is in progress. The memory size is 16 Mbyte.

The display shows code 83.

The tens digit (8) displays that reload of program code from the I/O LIM's memory or program code
from external backup is in progress.

The units digit is incremented every second if any program unit has been successfully loaded during
this time.