Professional Documents
Culture Documents
RIG
OCTARIG
SUSPENDED
A CLASSIC.
WIDE SPANS.
WITHOUT COMPROMISE.
2
TECHNISCHEFEATURES
TECHNICAL FEATURES
OCTArig | suspended
3
OCTARIG
ELEVATED
STABILITY.
HIGH LOAD CAPACITY.
MOUNTED ON UPRIGHTS.
240 78
4
TECHNICAL FEATURES
OCTArig | elevated
REINFORCED
CONNECTION.
FOR HIGHER LOAD
CAPACITY.
5
OCTARIG
AS PYLON
ROOFED.
SELF-SUPPORTING.
THE PYLON DESIGN.
6
TECHNICAL FEATURES
OCTArig | Pylon
SELF-SUPPORTING CORNERS.
MORE FLOOR SPACE.
MORE IMPACT.
7
8
9
SUPPORTING BEA M R 102.01
240 × 80 MM R 200
Aluminium | for adaptor R 260
and connector R 290, for
31.8
installation of 4 × tension lock
80
Z 961/13
53.23 kg | 6930 mm 40 40
240
R 260
R 102
R 102
80.6
screw M 1075/20 (M4)
0.47 kg | 241 mm
240.6
3 R 102
R 135
DFS 84
Processing R 240
.7
Ø6
Notes
see page 41 60
180/20
2.53 kg
8
10
COMPONENTS
OCTArig
C O N N E CT OR R 200.01
FOR R 2 6 0
Ø35 R 200
Aluminium/Steel | to mount
adaptor R 260 in case of
suspension, incl. eyelet, with 16 x
303
thread M10
241
2.92 kg R 260
Attention: max.
15.8
load capacity
80
M10
R 102 R 102
500 kg
80
C O N N E CT OR R 210.37
FOR R 2 6 0 / D F S 8 4
Aluminium/Steel | to mount R 210
240
adaptor R 260 for elevation of the
construction, plug on and screw M10 R 102
480
80
to uprights made of DFS 84, incl.
16 × thread M10
DFS 84 R 240
7.02 kg
43
C O N N E CT OR R 400.37
FOR PYL O N C O N S TR U C TI O N
Aluminium/Steel | for pylon
construction with tension brace
junction knot R 408, to screw on
273
M10
R 102
1.98 kg
M10
R 400
80
A N G L E REINFORCEMENT R 240.37
FOR R 2 6 0 / D F S 8 4
Steel | for reinforcement of R 210
elevated OCTArig designs, two-
piece, incl. 4 × contersunk screw R 102 Attention: R 260
DFL 340/5S(M8), 2 × contersunk required for
240
A D A P TOR R 260.01
FOR DFS 8 4 / R 1 0 2
R 200
Aluminium | to mount to upright
extrusion DFS 84 and supporting Attention: R 260
151.6
138
11
CONN ECTOR R 290.01
S TR A I G H T
Attention: R 290 Aluminium | for connection of
required for 2 × supporting beam R 102,
mounting of incl. 12 × countersunk screw
151.6
extended
138
DFL 340/5S (M10)
supporting beam 2.30 kg l 450 mm R 290
between two 46 450
upright extrusions R 102
DFS 84.
FIXING S ET R 300.37
W I TH EY E L E T R 300
Ø35
127
1.06 kg
Attention: max.
load capacity 15.8
R 102
300 kg 73 89
32
20
connector R 200, incl. cylinder
screw R 408-20 (M16)0.32 kg
24
R 102
8
Ø68
R 102
M8
safety
40
0.46 kg
reasons.
12
COMPONENTS
OCTArig
B E A M RETAINER R 322.37
FOR R 1 0 2
R 322
Steel | for additional securing 300
of 3 × supporting beam R
37
102 at an angle of 90°, incl. 2
× hammerhead screw M 810/
HA (M10) and 4 × Attention:
hammerhead screw E 265 necessary for
120
40
(M10) R 102 safety
0.90 kg reasons.
B E A M RETAINER R 330.37
FOR M 7 7 0
150 R 330
Steel | for additional securing of
supporting beam M 770 to
25
M 770
37
4
supporting beam R 102 at an
angle of 90°, incl. 4 ×
hammerhead screw M 810/HA Attention:
(M10) necessary for
safety
120
0.43 kg
R 102 reasons.
H I N G E D END PL AT E S ET R 350.21
FOR M 7 7 0
Steel | for connection of supporting R 350
45
11.8
35.53 kg | 6930 mm
20.8
38.8 38.8
40
7.5
40 4.3
200
R 102
E N D C AP R 355.35
1.6
7.6
R 102 R 355
13
END CAP R 358.35
Ø17 R 358
FIXING-S ET R 362.90
FOR R 365
Steel/Aluminium | to slide into the
60
4.3 mm system groove from the
100
side, incl. 1 × hammerhead screw
R 102
E 265 and mount for round tube
164
Ø 50 mm Ø50
Attention: max.
0.64 kg
load capacity
100 kg R 365 R 362
R 102
2
R 365 R 362
R 102
fixing accessories M5 (SW 8 mm)
0.02 kg ~21 32
32
R 370
ADAPTOR M 1172.37
F O R R O P E SU SP EN SIO N
Steel | usable for rope 10 M 1172
suspension, for connection to Ø22
15.5
14
COMPONENTS
OCTArig
A D A P TOR M 1174.37
FOR ROP E S U S P E N S I O N
Steel | usable for rope Ø22
M 1174
15.5
suspension, for connection to
4.3 mm system groove, incl. 2 ×
65.6
set screw M 1435/70 (M8) and
33.5
2 × lenticular flange head screw
M 1557/20 (M6) Attention: max.
0.25 kg 76 8
load capacity
100 kg
R 1 0 2 – FABRIC MOUNTING
M 1325 M 1330
M 1310 M 1310
M 1358 M 1360
M 1449
15
Cross-section values for upright extrusion DFS 84 and rectangular extrusion R 102
L EGEND EXT R U SI O N O U T ER D I M EN SI O N C EN T R OI D A L A X I S
A cross-section h b ey ez
G weight mm mm mm mm
b
ez ez
b
ez ez
eyo
ey
DFS 84 R 102
y
h
h
ey
eyu
EXT RUSION A G Jy Wy iy Jz Wz iz
ey ez
136.79
The given data is valid under the condition that the extrusions are structurally prevented from twisting.
Sufficient evidence for both flexural buckling and torsional flexural buckling has to be provided. Values printed
in blue indicate reaching of the tension limit with a safety factor of 1.35. Load figures include the dead weight
of the extrusion, i.e. the indicated load can be used in whole for addtional extrusions or exhibits. Flexible
mounting was estimated for calculation so as to demonstrate load bearing capacity and deflection of the R 102
extrusion. In combination with the R 260 adaptor, the R 200 (or DFS 84) connector and the R 102 supporting
beam feature a maximum moment of 5.5 kNm. The true deformation can be a little bit more than stated in the
table below as any slippage between the components cannot be taken into account.
Single load in centre of beam (kg) 2750 2200 1830 1565 1365 1210
Evenly distributed load (kg/m) 2750 1760 1220 890 685 490
Single load in centre of beam (kg) 2750 2200 1830 1510 1150 910
Evenly distributed load (kg/m) 2750 1760 1090 660 460 325
Single load in centre of beam (kg) 1085 915 765 645 550
Single load in centre of beam (kg) 735 603 502 422 358
Maximum admissible load (in addition to dead load) and resulting calculated deflections of single span
beams at permitted maximum deflection of 1/200 or 1/300 of span.
17
Load-bearing capacity – Beam extension examples with connector R 290
The following examples show how the possible load capacity increases in equally long constructions with
hinged single span beams the closer the extension is in the edge area.
PLEASE NOTE: Static calculation of the construction might be necessary in particular cases!
R 290
4000 mm 4000 mm
8000 mm
Single load in centre of beam (kg) 174 Single load in centre of beam (kg) 174
Deflection 1/200 (cm) 4.00 - vorh. 1.89 (P)* Deflection 1/300 (cm) 2.67 - vorh. 1.89 (P)*
4.00 - vorh. 2.25 (L)** 2.67 - vorh. 2.25 (L)**
R 290 R 290
Single load in centre of beam (kg) 410 Single load in centre of beam (kg) 260
R 290
6000 mm 2000 mm
8000 mm
Single load in centre of beam (kg) 360 Single load in centre of beam (kg) 262
Deflection 1/200 (cm) 4.00 - vorh. 3.54 (P)* Deflection 1/300 (cm) 2.67
4.00 - vorh. 2.99 (L)**
R 290
7000 mm 1000 mm
8000 mm
Single load in centre of beam (kg) 410 Single load in centre of beam (kg) 260
19
R 290 R 290
Single load in centre of beam (kg) 314 Single load in centre of beam (kg) 195
R 290
6000 mm 3000 mm
9000 mm
Single load in centre of beam (kg) 225 Single load in centre of beam (kg) 195
Deflection 1/200 (cm) 4.50 - vorh. 3.39 (P)* Deflection 1/300 (cm) 3.00
4.50 - vorh. 3.15 (L)**
R 290 R 290
B E A M SPAN 1 + 7 + 1 M = 9 M (E CCENTRIC E XT EN SI O N )
Single load in centre of beam (kg) 314 Single load in centre of beam (kg) 195
R 290
7000 mm 2000 mm
9000 mm
Single load in centre of beam (kg) 314 Single load in centre of beam (kg) 195
21
R 290 R 290
Single load in centre of beam (kg) 241 Single load in centre of beam (kg) 145
R 290
6000 mm 4000 mm
10000 mm
Single load in centre of beam (kg) 157 Single load in centre of beam (kg) 145
Deflection 1/200 (cm) 5.00 - vorh. 3.54 (P)* Deflection 1/300 (cm) 3.33
5.00 - vorh. 3.51 (L)**
R 290 R 290
Single load in centre of beam (kg) 241 Single load in centre of beam (kg) 145
R 290
7000 mm 3000 mm
10000 mm
Single load in centre of beam (kg) 219 Single load in centre of beam (kg) 145
Deflection 1/200 (cm) 5.00 - vorh. 4.61 (P)* Deflection 1/300 (cm) 3.33
5.00 - vorh. 3.51 (L)**
23
R 290 R 290
Single load in centre of beam (kg) 187 Single load in centre of beam (kg) 108
R 290
6000 mm 5000 mm
11000 mm
Single load in centre of beam (kg) 118 Single load in centre of beam (kg) 108
Deflection 1/200 (cm) 5.50 - vorh. 3.91 (P)* Deflection 1/300 (cm) 3.67
5.50 - vorh. 4.20 (L)**
R 290 R 290
Single load in centre of beam (kg) 187 Single load in centre of beam (kg) 108
R 290
7000 mm 4000 mm
11000 mm
Single load in centre of beam (kg) 150 Single load in centre of beam (kg) 108
Deflection 1/200 (cm) 5.50 - vorh. 4.65 (P)* Deflection 1/300 (cm) 3.67
5.50 - vorh. 4.51 (L)**
25
R 290
6000 mm 6000 mm
12000 mm
Single load in centre of beam (kg) 90 Single load in centre of beam (kg) 77
Deflection 1/200 (cm) 6.00 - vorh. 4.38 (P)* Deflection 1/300 (cm) 4.00
6.00 - vorh. 5.04 (L)**
R 290 R 290
Single load in centre of beam (kg) 145 Single load in centre of beam (kg) 77
R 290 R 290
Single load in centre of beam (kg) 145 Single load in centre of beam (kg) 77
R 290
7000 mm 5000 mm
12000 mm
Single load in centre of beam (kg) 110 Single load in centre of beam (kg) 77
Deflection 1/200 (cm) 6.00 - vorh. 4.97 (P)* Deflection 1/300 (cm) 4.00
6.00 - vorh. 5.25 (L)**
27
TECHNICAL INFORMATION
OCTArig | Processing Notes
B 147
length
Processing of rectangular
beam extrusion R 102 for
use with rectangular
38
beam extrusion R 102
B 146
M 10 (16x)
Processing of upright pylon extension
DFS 84 for use with adaptor connector
120 60
R 260 and angle reinforcement R 240
28
16 × thread M10,
4 × drilling Ø 10.5 mm, 120 240
Länge
8 × thread M8 (front)
B 148
Ø10.5 (4x)
M10 (16x)
B 149
length
Processing of upright extrusion DFS 84 120 120 240
If required for use with upright extrusion DFS 84 as
4 additional holes connector
Ø 10.5 mm and/
or 4 threads 4 × drilling Ø 10.5 mm
M8 (Please Ø10.5 (4x)
specifiy when Ø10.5 (4x)
if required, additional hole for upright extension
ordering.)
28
29
EXHIBITION SYSTEMS
PROJECT SOLUTIONS
PRESENTATION
INTERIOR DESIGN
CLEANROOM SYSTEMS
EUROPE AMERICA
OCTANORM® Germany
Head Office OCTANORM® Belgium OCTANORM® North America
T. +32 2 344 9880 T. +1 770 7 32 1520
Raiffeisenstraße 39 www.octanorm.be www.octanormna.com
70794 Filderstadt
T. +49 711 77003-0 OCTANORM® France OCTANORM® México
F. +49 711 77003-53 T. +33 1 4695 5406 T. +52 55 5804 6325
info@octanorm.de www.octanorm.fr www.octanorm.com.mx
www.octanorm.com OCTANORM® UK OCTANORM® Brasil
T. +44 20 85 45 2945 T. +55 11 3807 2552
www.octanorm.co.uk www.octanorm.com.br
AW 7948.GB_OCTARIG_01/2019
OCTANORM® Polska OCTANORM® Emirates
T. +48 22 773 0350 T. +971 4 340 6888
www.octanorm.pl www.octanormemirates.net