Professional Documents
Culture Documents
Riy-9004-Riy-9004-01 Civil Route Drawing (00000002)
Riy-9004-Riy-9004-01 Civil Route Drawing (00000002)
RIY-SAFR
HH-7010
24.677466
46.623313
m
49
:01
10
70
R-0
AF
Y-S
:RI
/16
20
UG
RIY-9004::RIY-9004:02
p
UG
20/
RIY-SAFR
16:
RIY
HH-7009
-SA 2m
24.676784
FR
-07
46.622183
011
:02
27m
p
RIY-SAFR
HH-7011
2m
24.67619
46.624647
UG20/16:R
IY-SAFR-0
7009:0283
m
2m
RIY-SAFR
HH-7010
24.677466 p
RIY-SAFR
HH-7008
24.674245
46.622365
46.623313
2m
m
49
01
263m
:
10
008:0
FR-07
70
IY-SA
/16:R
-0
UG20
R
AF
-S
IY
: R
16
2m
/
20
G
U
p
p
RIY-SAFR
HH-7007
24.671949
U
:61 0/2G
46.621915
RI Y- S A F
R0
- 7
00
7:
0
0
9m
8
p
UG
RIY-SAFR
HH-7006
24.671309
46.621917
20
2m
RIY-SAFR
/16
MOT CROSS SECTION
:R
HH-7009
IY
-S
UG20/16
AF 2m
:RIY-SA
24.676784
FR-0700
R-
6:0214m
07
46.622183
01
1:0
22
7m
p
RIY-SAFR
HH-7005
24.669432
46.622401
UG2
0/16:
RIY-
p
SAFR
-070
05:01
51m
30M MILLING&ASPHALT RIY-SAFR
p
RIY-HODA
HH-7004
24.668158
46.622946
UG2
0/16:
RIY-
HOD
A-07
HH-7011
004:0
143m
2m
24.67619
46.624647 p
RIY-HODA
HH-7003
24.666951
46.623462
2m
UG2
0/16
:RIY
-HOD
A-07
003:
0226
m
UG20/16
RIY-HODA
p
HH-7002
24.665045
46.624272
:RIY-SAF
2m
R-0700
UG2
0/16
:RIY
-HOD
A-07
002:
0289
9:0
m
283m
284m
001:0
DA-07
IY-HO
/16:R
UG20
5CM
2m
p
2m
RIY-HODA
p
RIY-HODA
HH-0050 HH-7001
24.662884 24.662851
46.622361 46.624657
2m
ASPHALT/TILES Legend
b BTS ! ! ! !
Electric Cable
20CM
'ÁT DWDM >!
Optical Fiber Cable
p
50-60CM
CONCRETE RIY-SAFR
HH-7008
24.674245
46.622365
þ FDT UTP Cable
2m
D ODF Drop Duct Operational
25CM 10CM
63m
CONCRETE
8:02
700
FR-0
-SA
ONT Drop Duct Temporary
IY
!
/16:R
0
UG2
8 PoleBox Drop Duct Third Party
FAT Main Duct Abandoned
DUCT 3BÇ
2m
LENGTH e! Cabinet Main Duct Operational
p p HH, Abandoned Main Duct Planned
10-15CM(WIDTH) RIY-SAFR
HH-7007
24.671949
U
: 610/2G
46.621915
p HH, Implementation Main Duct Temporary
RIY-S AF
R- 0
7 00
p HH, Operational Main Duct Third Party
7:
08
0
9m
p
RIY-SAFR p HH, Planned Un-Known Building Type
HH-7006
24.671309
46.621917
p HH, Temporary SDU, Survey
2m
p HH, Third Party SDU, Design
)p MH, Abandoned SDU, RFS
UG20
/16:R
IY-SA
)p MH, Implementation SDU, Operational
FR-070
06:0214m
)p MH, Operational ( MDU, Survey
)p MH, Planned ( MDU, Design
)p MH, Temporary ( MDU, RFS
p
RIY-SAFR
)p MH, Third Party ( MDU, Operational
HH-7005
24.669432
46.622401 Pole Vacant Area
» Shelter Parcel
UG
20/1
6:R
IY
Copper Cable FAT_Boundary
-SA
FR
-07
005
:01
51m
Notes & Comments:
1. Use Dawiyat Standards for Ducts, Cables, Trenches & ODN
p
RIY-HODA
HH-7004
24.668158
46.622946
UG
2. Do Trial Trenches before excavation
.
2m
UG
20/1
5CM
6:R
IY-H
OD
A-0
700
3:0
ASPHALT/TILES
226
m
CLUSTER STATISTICS
HH LAYOUT
20CM
p
HH Category
50-60CM
CONCRETE RIY-HODA
HH-7002
24.665045
46.624272
Cluster ID
MDU SDU VA
Total House Holds
WARNING TAPE
25CM 10CM
2m
CONCRETE
UG
20/1
6:R
IY-H
OD
A-0
700
2:0
289
m
DUCT 2m
UG2
0/16:R
IY-H
ODA-0
700
1 :028
4 m
p
RIY-HODA
p
RIY-HODA
Prepared by : Date : 16-06-2021
HH-0050
10-15CM(WIDTH)
HH-7001
24.662884 24.662851
46.622361 46.624657
Checked by : Map Scale : NTS