You are on page 1of 1

4.

Splitting Failure due to loading Resistance:

The characteristic resistance of Anchor Bolt in case of spliting Failure:

where, "Ψh,sp = factor to account for the influence of the actual


member depth, H,
on the splitting resistance for anchors = (H/hef)^(2/3) < =1.5"

The characteristic resistance of Anchor Bolt in case of Splitting Failure,


NRk,sp =
479.8313573

Design resistance of Anchor Bolt in case of Splitting Failure, NRd,c = NRk,sp


/γMsp =
266.5729763

Design tensile force in Anchor Bolt, NSd =


447 kN > 267 kN Additional
Reinf. Required

Reinforcement to be provided within 0.75 hef


= 125 mm
Yield strength of steel (Grade of steel), fy
= 500 N/mm2
Partial safety factor for steel reinforcement, γs
= 1.15
Reinforcement required
= Tension per bolt / (fy / γs)
=
197.34 mm2
Provided Reinforcement
= 4 Nos. 16 dia reinforcement bar per bolt within 0.75hef