CAC ACCESSORIES

0CAA9-01A
LG Airconditioners Product Data

TABLE OF CONTENTS
Table of contents Page

• Wireless Remote Control............................................................................................3


• General Central Control..............................................................................................5
• Zone Control ...............................................................................................................8
• Tele Control...............................................................................................................12
• Low Ambient Kit........................................................................................................14
• Low Static Motor .......................................................................................................17
• Drain Pump...............................................................................................................18
• Electric Heater-Duct Split .........................................................................................23
• Electric Heater- Single Package ...............................................................................26
• Plasma Air purifier ....................................................................................................29
• Electronic Thermostat...............................................................................................31
• Manual Hood ............................................................................................................34
• RF Remote Control...................................................................................................37
• Air Guide...................................................................................................................40
• Elevation Grille kit .....................................................................................................41
• Branch Distributor .....................................................................................................42
• Y Branch ...................................................................................................................47
• Header ......................................................................................................................48
• Dry Contact module..................................................................................................52

CAC Accessories 1
2 CAC Accessories
Wireless Remote Control

Accessory Name Wireless Remote Control


Deluxe
Type Simple
(LCD Type)
Accessory Model
Name Cooling only General For Ducted Split & Single Package AHWRCD
Heat Pump AHWRHS AUWRHS AHWRHD

• It provides control flexibility.

Functions Deluxe Simple


Air circulation / Fan operation
Room temperature checking
Functions Sleep mode operation
Temperature settings
Operation mode selection
Air-swing & Jet cool (Cassette Only)
On/Off Timer settings

Picture

AHWRHS AHWRCD
AUWRHS AHWRHD

• Wireless Remote Control .......................1EA


Parts Supplied
• Installation Manual .................................1EA

• Applicable to Ceiling Cassette, Ceiling Concealed Duct, Ducted Split & Single
Applicable Models Package (6.25~25RT).

Installation Procedure :-
Mounting on the wall

1. Mount the remote control stand on the wall with the help of screw dri-
ver and screw purchased locally.

2. Insert the remote control in the stand.

CAC Accessories 3
Wireless Remote Control

How to insert batteries :

1. Remove the battery cover from the remote control. Slide the cover
in the direction of arrow.

2. Insert two batteries. Take care about the polarity(+/-) and batteries
should be new.

3. Re-place the cover by sliding it back into position.

How to Use :
For Ceiling Cassette :
Point the signal transmitter towards the front panel of the cassette indoor unit (for C, D, E, F Chassis
models) and press any function key. For B chassis point the signal transmitter towards the wired remote
control and press any function key.

For Ceiling Concealed Duct, Ducted Split & Single Package :


Point the signal transmitter towards the wired remote control and press any function key.

1. Do not use rechargeable batteries for wireless remote control .


Remarks 2. Remove the batteries from the remote control if the air conditioner is not
going to be used for long time.

4 CAC Accessories
General Central Control

Accessory Name Central Control

Accessory Model AQCC


Name

• Individual On/Off Function


• Individual Operating monitor (LED Display)
• Total On/Off Function
Functions • Diagnostic Funciton
• Lock Funciton (Individual, Total Lock)
• Sequential starting to prevent over current

On/Off display LED Individual On/Off button


(Total 16EA) • Control ON/OFF of a unit.
• If pressing individual on/off button,
display the present operation state.
-Operation : green.
-Stop : off
-Error mode : blinking

Picture
Power display LED
• Indicate the state of DC
Power supply in central
controller unit. Total Off button
-On : red • Stop all linked units sequentially.
-Off : no signal
- Error mode : blinking Total On button
• Operate all linked units sequentially.

• Factory Supplied : • Purchased Locally :


- Central Control .......................1EA - Lead Wire ...............................7EA
- *Sub PCB .............................16EA - Screw......................................4EA
Parts Supplied - PCB Supporter .....................64EA
- Lead Wire Assembly...............1EA
- Installation Manual..................1EA
- **Terminal Block ...................16EA

* : For Ceiling Cassette, Ceiling Concealed duct, Floor Standing


** : For Ducted Split, Single Package

Applicable Models • Applicable to Ceiling Cassette, Ceiling Concealed Duct, Floor Standing, Ducted
Split & Single Package.

CAC Accessories 5
General Central Control

Installation Procedure :
1. Hold the control as shown in the picture than push
the front case slightly and pull front & rear cases in
front & rear direction to separate the case.
2. Set screws to the holes of case.

3. Set the dip switch according to Range of Control as Range of Control 1~16 Set 17~32 Set 33~48 Set 49~64 Set

explained in table.When linking more than 2 sets, DIP S/W ON


Setting Method
eliminate R66(1Ω) resistorfrom PCB of controls con- OFF 1 2 3 4 1 2 3 4 1 2 3 4 1 2 3 4

trolling 17th ~128th indoor unit. Don't remove resis- Range of Control 60~80 Set 81~96 Set 97~112Set 113~128 Set

tor of control controlling 1st ~ 16th units. DIP S/W


Setting Method
ON

OFF 1 2 3 4 1 2 3 4 1 2 3 4 1 2 3 4

4. Also set the dip switch on main PCB assembly


according to setting order.

R66
CH1

S1 S2

5. Connect the terminal referring below table.


CH2
CH1 TA
TERMINAL WIRE COLOR CONNECTING TERMINAL TB

TA Red ↔ DC 12Vof indoor unit


Black ↔ DC Ground of indoor unit, TB terminal
TB
of the other control
CH1 Blue ↔ Signal port of indoor unit
CH2 White ↔ CH2 of the other control

6. After attaching the supply wire to terminal, link the


connecting wire . Cut the indicated rounded parts of
front case to draw the lead wire, if necessary. After
that Push the front case to the rear case to assem-
ble.

7. Supply the power to check control operation.

6 CAC Accessories
General Central Control

Wiring Schematic :
- Ceiling Cassette
- Ceiling Concealed Duct
- Floor Standing

M M M M M M M M M
1 2 16 17 18 32 113 114 128

Sub Sub Sub Sub Sub Sub Sub Sub Sub


1 2 16 17 18 32 113 114 128
CH1
CH2
TB
TA

CH1
CH2
TB
TA

CH1
CH2
TB
TA
CENTRAL CENTRAL CENTRAL
CONTROLLER CONTROLLER CONTROLLER
#1 #2 #8

- Ducted Split
- Single Package

M M M M M M M M M
1 2 16 17 18 32 113 114 128

T/B T/B T/B T/B T/B T/B T/B T/B T/B


1 2 16 17 18 32 113 114 128
CH1
CH2
TB
TA

CH1
CH2
TB
TA

CH1
CH2
TB
TA

CENTRAL CENTRAL CENTRAL


CONTROLLER CONTROLLER CONTROLLER
#1 #2 #8

(T/B: Terminal Block)

1. Avoid installing control nearby computer, automatic door & elevator.


Remarks 2. Avoid installing control nearby extremely humid area.
3. Avoid installing control under direct Sun- rays.

CAC Accessories 7
Zone Control

Accessory Name Zone Control


Accessory Model ABZCA
Name
1) Operation Summary
- A device which senses temperature of each zone controls operation of each dif-
fuser, so temperature of each zone can be controlled.
2) Specific Operation
- If every zone (diffuser) is closed, Comp and outer fan become turned off to
protect compressor.
* Zone controller requires diffuser temperatures and controllers available locally.
Operating Scene
- The temperature of all zones are con-
trolled individually (makes energy savings)
Functions - Controlled by the signal of every zones in
duct system (By connecting the ther Zone A Zone B
mostat and VAV Diffuser to Main PCB,
comp. & fan)
• Diffuser and Thermostat are locally Zone C Zone D
sourced
- Connected to Another Apparatus, Control
it Freely

Case
Main lead wires
Zone Control PCB

Picture

Trans

• Factory Supplied : • Purchased Locally :


- Zone Control PCB ..................1EA - Damper Motor
- Trans ......................................1EA - Thermostat
- Case .......................................1EA - Damper
Parts Supplied - Cover ......................................1EA
- Main lead wires.......................1EA
- Screws....................................4EA
- Holder .....................................4EA
- Installation Manual..................1EA

Applicable Models • Applicable to Ceiling Concealed Duct type air conditioners.

8 CAC Accessories
Zone Control

Installation Procedure :-
• The control should be mounted to control panel using 4 screws sup-
plied.
• Fasten it to any holes on control panel as long as there is enough
space to install. If necessary drill holes to install on proper position.
• When drilling, ensure that metal swarf does not foul any electronic
components.

Wiring Diagram :

• Connect main lead wires between main PCB and Zone Control.
• Connect thermostat to Zone Control according to thermostat maker's manuals.
• Connect Damper Motor to Zone Control according to Damper Motor maker's manuals.

CAC Accessories 9
Zone Control

Wiring also depends upon the type of the damper actuators.

• Spring Return Damper Actuators

L L L L
Indoor Unit
Damper Damper Damper Damper
Trans : 12VA
Zone CH1 Thermostat #1 Motor Motor Motor Motor
(24V/130mA*4) CH2 Thermostat #2
Controller CH3 Thermostat #3 #1 #2 #3 #4
Trans PCB CH4 Thermostat #4
N
COM N N N
COM
COM
COM
AC 24V
Main 24V
PCB 24V
Power Input
24V
AC(L) AC(N)

AC220~240V 50/60Hz

• Non Spring Return Damper Actuators

S S S S
Indoor Unit
Damper Damper Damper Damper
Trans : 12VA
(24V/130mA*4) Zone CH1 Thermostat #1 Motor Motor Motor Motor
CH2 Thermostat #2
Controller CH3 Thermostat #3 #1 #2 #3 #4
Trans PCB CH4 Thermostat #4
N
COM N N N
COM
COM
COM
AC 24V
Main 24V
PCB 24V
Power Input
24V
AC(L) AC(N)

L : Live
N : Neutral
AC220~240V 50/60Hz S : Signal

By Pass Damper System :-

Return HVAC Supply

By-pass damper Static


pressure
control
24 VCA
power supply
Closed
Open
40 VA 2 3
transformer NC NO
1
Common
3-Canle damper motor
Pressure controller

To maintain an adequate flow of air and static pressure through the HVAC system, a by-pass system
can be used that is equipped with a motorized damper and a static pressure control.

10 CAC Accessories
Zone Control

When the area dampers open or close, the static pressure control will open or close the by-pass damper so
as to maintain the adequate static pressure. Dimensions of the by-pass damper depends on the cooling
capacity of the unit.

Btu/h Size of the by-pass (ø)


36K 250 mm
42K 250 mm
48K 300 mm
60K 300 mm
91K 350 mm
120K 350 mm

Remarks • Turn off the Power before installation or maintenance.

CAC Accessories 11
Tele Control

Accessory Name Tele Control

Accessory Model AQTCA


Name

• It provides ease of control.


Functions • Air conditioner can be switched on/off by the telephone. It saves time &
energy.

Picture

- Tele Control PCB.................................................................................1EA


- Connecting wire between main PCB and Tele control ........................1EA
Parts Supplied - Telephone Line(10m)...........................................................................1EA
- Installation Manual...............................................................................1EA

Applicable Models • Applicable to Ceiling Concealed Duct & Floor Standing type of air conditioner.

Installation Procedure :
1. Connect the tele control PCB with main Socket
PCB of Indoor unit through the connecting
wire provided. Tele-Control
PCB ASM

3 Wire
Main PCB

12 CAC Accessories
Tele Control

2. Connect the tele control PCB to the telephone line with a


multi plug.

Multi Plug Telephone Line

Socket

Tele-Control
PCB ASM
Telephone Line Plug

System Schematic :-
Multi Plug Telephone Line

Socket

Tele-Control
PCB ASM Normal & ARS Telephone
Telephone Line Plug

Telephone Line

3 Wire Condition may


Main PCB not be same

Indoor unit

Remarks Turn off the Power before installation or maintenance.

CAC Accessories 13
Low Ambient Kit

Accessory Name Low Ambient Kit

Accessory Model AQLA


Name

• Even when the outdoor temperature reaches low ambient with low ambient kit
you can get cooling operation.
Functions • As the ambient air temperature rises and falls, the outdoor fan speed increases
and slows down, to produce the variable cooling effect needed to give constant
pressure.

Picture

- AQLA Fan Speed Control.........(1EA) - Tie Wrap,100mm ......................(2EA)


- Sensor Assembly .....................(1EA) - Instruction Manual ....................(1EA)
- Buckle-clip ................................(3EA) - Screw ......................................(3EA)
Parts Supplied - Adhesive Insulation, 20mm x 80mm
.................................................(1EA)

Applicable Models • Applicable to Convertible, Ceiling Cassette & Ceiling Concealed Duct.

Wiring Diagram : (For Cooling Only type)

Low Ambient Controller

14 CAC Accessories
Low Ambient Kit

(For Heat - Pump type)


Low Ambient Controller

Installation Procedure :-
Fixing : - The control should be mounted to control panel within the condensing unit using two screws sup-
plied. Fasten it to any holes on control panel as long as there is enough space to install.
If necessary, drill holes to install on proper position.

Electrical Connections :-

(MOTOR)
MAIN L 1
INPUT N 2 P.C.B.
ROOM
SUPPLY N 3
TO FAN(S) L 4 SW01F
5
PIPE
6
7
8
9 P1 P2

1 = Live input
2 = Neutral input
Sensor 3 = Neutral output (to motor)
4 = Live output (to motor)
5 = Do not use
FROM 4 WAY VALVE 6 = Live from 4 way valve
7 = Neutral from 4 way valve
8 = sensor
9 = sensor

Some condensing units are equipped with two fans. In that case, connect the lead wire of each motor to ter-
minal numbers 3 and 4. But some condensing units also require a separate control for each fan.

Heat Pump Models : - When the Low Ambient Control is to be used with a Heat Pump, the condenser fan
needs to run at full speed during the heating mode, and is only modulated during
the cooling mode.
When fitted to a Heat Pump, terminal numbers 6 and 7 should be wired directly to
the reversing solenoid valve ; in all cases both live and neutral side of solenoid
valve should be connected to the control.

CAC Accessories 15
Low Ambient Kit

Cooling Only Models : - On cooling only units, where a reversing valve is not fitted, terminal numbers 6 and
7 Should be left unconnected.

Fitting the Sensor : - Locate a return bend, two or three bends above a convenient liquid line exit from the
Condenser. This should ideally be chosen with its temperature closest to that of dis-
charge saturation temperature.

Setting the Control : - First check whether switch SW01F is towards pipe or not. If not than slide it towards
pipe.
Rotating part (use a proper tool to rotate) ROOM

F 0 1 F 0 1
E 2 E 2
D 3 D 3
C 4 C 4
B 5 B 5
A 6 A 6
9 8 7 9 8 7 PIPE Opt A

Fig. 1: Rotary S/W P1 Fig. 2: Rotary S/W P2 Fig. 3: S/W SW01F


(default:4) (default:8) (default: PIPE )

Preset temperature at the condenser outlet can be set by switch S/W P1 and accordingly the fan on /
off temperature will be as follows :
Opt 0 Opt 1 Opt 2 Opt 3 Opt 4 Opt 5 Opt 6 Opt 7 Opt 8 Opt 9 Opt 10 Opt 11 Opt 12 Opt 13 Opt 14 Opt 15

PRESET TEMP 19°C 20.5°C 22°C 23.5°C 25°C 26.5°C 28°C 29.5°C 31°C 32.5°C 34°C 35.5°C 37°C 38.5°C 40°C 41.5°C

FAN OFF TEMP 2°C 3.5°C 5°C 6.5°C 8°C 9.5°C 11°C 12.5°C 14°C 15.5°C 17°C 18.5°C 20°C 21.5°C 23°C 24.5°C

FAN ON TEMP 4°C 5.5°C 7°C 8.5°C 10°C 11.5°C 13°C 14.5°C 16°C 17.5°C 19°C 20.5°C 22°C 23.5°C 25°C 26.5°C
Table : Setting Temperatures ; Controlled by rotating P1

100 Opt F
90 Opt E
Opt F Opt D
80
According to preset temp. - 0 or 1 or 2, Opt C
70 Opt B
.........17, you can read the % speed ratio
Speedratio(%)

Opt A
60 Opt 9
from graph. The variation in % speed ratio is Opt 8
50
changed by position of switch S/W P2. Opt 0 Opt 7
40 Opt 6
30 Opt 5
Opt 4
20 Opt 3
Opt 2
10
Opt 1
0 Opt 0
0˚C

1˚C

2˚C

3˚C

4˚C

5˚C

6˚C

7˚C
Tem C
˚C

Tem C
˚C

Tem C
˚C

Tem C
˚C

Tem C
Tem ˚C
˚

˚
p.-0

p.-1

p.-2

p.-3

p.-4

p.-5

p.-6

p.-7

p.-8

p.-9
p.-1

p.-1

p.-1

p.-1

p.-1

p.-1

p.-1

p.-1
Tem

Tem

Tem

Tem

Tem

Tem

Tem

Tem

Tem

Tem

Tem

Tem
set

set

set

set

set

set

set

set

set

set
set

set

set

set

set

set

set

set
Pre

Pre

Pre

Pre

Pre

Pre

Pre

Pre

Pre

Pre
Pre

Pre

Pre

Pre

Pre

Pre

Pre

Pre

Preset temperature (¡C)


Graph : Speed ratio(%) ; Controlled by rotating P2

- Disconnect all power supplies before starting installation or maintenance work.


- The control & sensor are to be safely enclosed within the condensing unit.
Remarks
- All electrical wiring must be carried out by a competent person, and must follow
the local & National Electric code.

16 CAC Accessories
Low Static Motor

Accessory Name Low Static Motor


Ceiling concealed Duct
Air Volume[CMM(CFM)]
Capacity V/Hz/Ø
Accessory Model Name High Middle Low
ABLME488 48k Btu/h 220-240/50/1 40 (1413) 35 (1236) 30 (1059)
ABLME608 60k Btu/h 220-240/50/1 45 (1589) 40 (1413) 35 (1236)

Functions • To maintain same air flow irrespective of static pressure.

Picture

- Motor ..........................................1EA - Mounted Motor ...........................1EA


Parts Supplied - Capacitor ...................................2EA - Installation Manual......................1EA

Applicable Models • Applicable to Ceiling Concealed Duct Models.

Installation Procedure :-
Replace the already installed motor with low static motor.

Remarks • Turn off the Power before installation or maintenance.

CAC Accessories 17
Drain Pump

Accessory Name Drain Pump


Ceiling Concealed Duct
Accessory Model Name D, F Chassis G, H Chassis E Chassis
ABDPD ABDPG ABDPE
• To remove the condensed water from the indoor unit.
Functions • In some of the places where natural drainage is not possible Drain Pump is very
useful to remove condensed water.

Picture

ABDPD/ABDPE ABDPG

Parts needed for servicing


Factory Supplied Parts
(Factory Supplied)
For D,E&F Chassis Models For D, E&F Chassis Models :
- Drain Pump Assembly
(AC220~240,50/60Hz,400CMM) 1EA
- Elbow (ø32) ................................1EA Part Name Part No.
- Hose ...........................................1EA Water Pump 5858A10001L
- Tie Wrap ....................................2EA Switch Assy, Float 6601A20001E
- Screw........................................10EA
Parts Supplied
- Rubber ........................................1EA
- Installation Manual......................1EA

For G&H Chassis Models : For G&H Chassis Models :


- Drain Pump Assembly
(AC220~240,50/60Hz,400CMM) 1EA Part Name Part No.
- Screw..........................................4EA Water Pump 5858A10001L
- Cap .............................................1EA Switch Assy, Float 6601A20001E
- Installation Manual......................1EA

Applicable Models • Applicable to D,E,F,G,H Chassis Ceiling Concealed Duct Models.

18 CAC Accessories
Drain Pump

Installation Procedure : - For D,E&F Chassis Models

Step 1. Separate the filter. Step 2. Open the top cover.

Step 3. Assemble the drain pump assembly. Step 4. Attach the elbow to the side panel.

Tighten 4 screws to the channel.


Tighten 2 screws to the Side Panel.

Step 5. Connect the hose and tie wrap. Step 6. Connect two lead wires to control box.

Connect two lead wires to control box, One wire is


for float switch and other Wire is for power supply to
drain pump.
Step 7. Assemble the top cover. Step 8. Close the drainage hole with the provided
rubber cap.

CAC Accessories 19
Drain Pump

Installation Procedure : - For G & H Chassis Models

Step 1. Separate the filter. Step 2. Open the top cover.

Step 3. Remove the knock-out from the side panel. Step 4. Assemble the drain pump assembly.

Tighten 4 screws to the Side Panel.

Step 5. Connect two lead wires to control box. Step 6. Close the drainage hole with the provided
cap.

Connect two lead wires to control box (One wire is


for float switch and other Wire is for power supply to
drain pump.)

Step 7. Assemble the top cover. Step 8. Insert the filter.

20 CAC Accessories
Drain Pump

Wiring Diagram :

For D,E&F Chassis Models :

INDOOR ELECTRIC CIRCUIT

THERMISTOR
BR

TEMP.
INDOOR DRAIN

GN/YL
MOTOR PUMP
YL

BL
BL
OR
RD

BK
BL
FUSE
1(L)

BR 250V10A

BL
2(N)
TO OUTDOOR UNIT

COMP

4 WAY
PIPE
RD Drain Pump Assy THERMISTOR
3

BK
4

FLOAT S/W
5

GN/YL REMOTE
CONTROL

TERMINAL
BLOCK
ZONE
CONTROL

For G & H Chassis Models :

INDOOR ELECTRIC CIRCUIT


THERMISTOR

YL
TEMP.

INDOOR DRAIN
GN/YL

MOTOR PUMP
OR
BR

BL
BL
BK

FUSE
250V 8A
1(L) 2(N)

BR
TRIAC
BL
TO OUTDOOR UNIT

COMP

4 WAY

PIPE
VENT

RD Drain Pump Assy THERMISTOR


3

BK
4

FLOAT S/W
BL BR
5

GN/YL REMOTE
CONTROL

TERMINAL
BLOCK T/B
A/CL TELECONTROL/ ZONE OPTION
UNIT CENTRAL CONTROL CONTROL
VENTILATOR

CAC Accessories 21
Drain Pump

Functions
For D,E,F,G&H Chassis Models :

- Possible drain-head height is up to 700mm.


So, installation must be below 700mm. 1/50~1/100

- Keep the drain hose inclined downward with a Drain Pipe


slope of 1/50~1/100. MAX 700mm
- Prevent upward or reverse flow.

Drain Pump

Thermal insulator
(Local supply)
- To prevent condensate forming over the drain
pipe minimum 5mm thick insulation should be Drainage pipe
applied. (Local supply)
Unit

Make sure to be closed. Drainage hole

- Upward rounding is not allowed.

Correct Incorrect

• Be sure that there should not be any leakage


after closing the drainage hole with the cap. Cap

Drainage Hole

• Disconnect the power supply before installation & maintenance.


Remarks • Check the drain pump for normal operation and abnormal noise after elec-
trical wiring.

22 CAC Accessories
Electric Heater-Ducted Split

Accessory Name Electric Heater-Ducted Split

Accessory Model • ANEH(Refer to Electrical Data)


Name

• To provide quick heating.


Functions • To provide additional heat with cycle heat.

Picture

Parts Supplied - Electric Heater ...........................1EA - Installation Manual ..................1EA


- Hexagonal bolt M6, L14............16EA - Hexagonal Nut..........................6EA

Applicable Models • Applicable to Ducted Split type Air Conditioner.

CAC Accessories 23
Electric Heater-Ducted Split

Installation Procedure :

1. First remove the flanges on the top cover in


case of 15RT and 20RT models.

2. Assemble the electric heater with the help of


screws provided with electric heater. Flange

Duct Flange
3. Assemble the duct flange to the electric heater (In the filter assy kit)
as shown in the figure.

Electrical Wiring :
Control Wiring :
1. Connect control wires(brown) on terminal block
(on PCB) as shown on wiring diagram attached on
control box cover.

Power Supply
Power Wiring : (High Voltage)
2. Connect the wires to high voltage terminal block.
Refer wiring diagram supplied with heater.

3. Fuse should be checked for correct specifications.


To Unit Control Box
Ground

4. Replace control box cover using screws.

24 CAC Accessories
Electric Heater-Ducted Split

Dimensional Drawing:
e

Removable Panel

Hole for High Voltage


Power Supply
a

c
b

Electric Heater for Ducted Split type air conditioner

ANEH0521A ANEH1021A ANEH09B1B ANEH18B1B ANEH18B1C ANEH36B1C ANEH36B2C


a 295.4 295.4 270.4 270.4 370.4 370.4 370.4
b 381.2 381.2 440 440 534 534 534
c 381.6 381.6 729 729 860.6 860.6 860.6
d 234.6 234.6 524 524 615.6 615.6 615.6
e 325.6 325.6 370 370 454 454 454
f 25.4 25.4 25.4 25.4 25.4 25.4 25.4

Electrical Data :
Applicable Heater Heater Heater Control Power Supply
Model(Ton) Model No. Kw Rating Kw Stages (Phase, Voltage)
3~5RT ANEH0521A 3.6/5.0 5 1 1ø, 208~240V
3~5RT ANEH1021A 7.2/10.0 10 1 1ø, 208~240V
6.25~12.5RT ANEH09B1B 7.8/9.0 9 1 3ø, 208~240V
6.25~17.5RT ANEH18B1B 15.6/18.0 18 1 3ø, 208~240V
15~20RT ANEH18B1C 31.2/36.0 18 1 3ø, 208~240V
15~20RT ANEH36B2C 31.2/36.0 18+18 2 3ø, 208~240V
Note : Heater kW ratings are at 240V.

Applicable Heater Heater Heater Control Power Supply


Model(Ton) Model No. Kw Rating Kw Stages (Phase, Voltage)
3~5RT ANEH0581A 5.0 5 1 3ø, 380~415V
3~5RT ANEH0981A 9.0 9 1 3ø, 380~415V
6.25~12.5RT ANEH0981B 9.0 9 1 3ø, 380~415V
6.25~12.5RT ANEH1881B 18.0 18 1 3ø, 380~415V
15~20RT ANEH1881C 18.0 18 1 3ø, 380~415V
6.25~12.5RT ANEH3682B 36.0 36 1 3ø, 380~415V
15~20RT ANEH3682C 36.0 18+18 2 3ø, 380~415V
Note : Heater kW ratings are at 415V.

1. Disconnect the power supply before starting installation or maintenance work .


Remarks 2. Installation must be carried out by a competent person, and must follow the
local & National Electric code.

CAC Accessories 25
Electric Heater-Single Package

Accessory Name Electric Heater

Accessory Model LKAEH(Refer to Electric Data)


Name

• To provide quick heating.


Functions
• To provide additional heat with cycle heat.

Picture

- Electric Heater ..................................1EA - Installation Manual ..........1EA


Parts Supplied - Heater Control Box ...........................1EA - Screws

Applicable Models • Applicable to Single Package type of air conditioner.


Installation Procedure :
1. Loosen the screws that secures heater
compartment access panel. Lift up and pull
panel towards outside. Heater Cavity

Support
Bracket
Heater Access Panel
Compressor Access Panel

2. Remove 4 screws from block off panel to


exposure heater cavity and heater's back
supporting bracket . Keep the screws for
installing heater later.
Block off panel

26 CAC Accessories
Electric Heater-Single Package

3. Insert heater into the opening hole of heater control box.


Heater

4. Align holes and secure screws to the control box as


shown in figure.

Heater Control Box

Single Bank Heater Installation :


5. Place the heater control assembly in the heater cavity.
Make sure that the heater arm slides into heater's sup-
porting bracket.
Supporting
Bracket

6. Secure the heater control assembly on heater cavity


using four screws.

Two Bank Heater Installation :


5. Place the heater control assembly in the heater cavity.
Make sure that the heater arm slides into heater's sup-
porting bracket.
Supporting
Bracket

6. Secure the heater control assembly on heater cavity


using four screws.

7. From the heater terminal posts marked L1, L2 and L3


remove the nut, lock washer and flat washer.

L2

8. Connect wiring from control box panel to the respective


terminal post as mentioned on heater's wiring diagram.
The sequence of assembling various parts is1) Wire
L3
Connector 2) Flat washer 3) Locking Washer and 4) Nut.
Do not over tighten the nuts on the heater terminals to
prevent ceramic insulation from damage.

CAC Accessories 27
Electric Heater-Single Package

9. Connect control wires(Brown) on terminal block


(and PCB) as shown on wiring diagram attached Terminal Block
on compressor access panel.

Ground
10. Connect power supply wires to high voltage ter-
minal block. Power Supply
Refer to wiring diagram supplied with heater.

To Unit Control Box.

Electrical Data :

Applicable Heater Heater Heater Control Power Supply


Model(Ton) Model No. Kw Rating Kw Stages (Phase, Voltage)
3~5RT LKAEH0521 3.6/5.0 5 1 1ø, 208~240V
3~5RT LKAEH1021 7.2/10.0 10 1 1ø, 208~240V
5RT LKAEH05B 4.3/5.0 5 1 3ø, 208~240V
6.25~12.5RT LKAEH09B 7.8/9.0 9 1 3ø, 208~240V
6.25~17.5RT LKAEH18B 15.6/18.0 18 1 3ø, 208~240V
15~17.5RT LKAEH36B 31.2/36.0 18+18 2 3ø, 208~240V
20~25RT LKAEH36BL 31.2/36.0 36 2 3ø, 208~240V

Note : Heater kW ratings are at 240V.

Applicable Heater Heater Heater Control Power Supply


Model(Ton) Model No. Kw Rating Kw Stages (Phase, Voltage)
5RT LKAEH058 4.2/5.0 5 1 3ø, 380~415V
6.25~12.5RT LKAEH098 7.5/9.0 9 1 3ø, 380~415V
6.25~17.5RT LKAEH188 15.1/18.0 18 1 3ø, 380~415V
6.25~17.5RT LKAEH368 30.2/36.0 18+18 2 3ø, 380~415V
20~25RT LKAEH368L 30.2/36.0 36 2 3ø, 380~415V

Note : Heater kW ratings are at 415V.

1. Disconnect the power supply before starting installation or maintenance work .


Remarks 2. Installation must be carried out by a competent person, and must follow the local
& National Electric code.

28 CAC Accessories
Plasma Air Purifier

Accessory Name Plasma Air Purifier

Type Capacity (Btu/h)


18K 24K 30K 36K 42K 48K 60K
ABPAHH Heat Pump
ABPAHC Cooling Only
Accessory Model Name ABPAGH Heat Pump
ABPAGC Cooling Only
ABPAEH Heat Pump
ABPAEC Cooling Only
ABPAEZ H/P + E/H

• To provide odor free, dust free, allergy free, clean & healthy air.
Functions • It not only removes microscopic contaminants & dust but it also removes house
mites, pollen, and pet fur to help prevent allergic diseases like asthma.

ABPAEH(C)

Picture

ABPAGH(C)

ABPAHH(C)

Plasma Air Purifier Kit........................1EA Installation Manual.................1EA


Parts Supplied Screws M4 .....................................12EA Wired Remote Control ...........1EA

Applicable Models • Applicable to Ceiling Concealed Duct type of air conditioner.

CAC Accessories 29
Plasma Air Purifier

Installation Procedure :
1. Disassemble the angle attached at the return of the indoor unit.
2. Fasten the Plasma Air purifier kit using supplied Screws (M4).
3. Do the wiring as per the wiring diagram provided with Plasma Air Purifier kit.
4. Confirm there is no gap between the indoor unit and Plasma Air Purifier Kit.
5. Reassemble detached angle to the back side of the plasma Air Purifier Kit box.

Dimensional Drawing :

Dimension (mm)
Model
H D W
ABPAHH
230 180 785
ABPAHC
ABPAGH
260 180 1,092
ABPAGC
ABPAEH
ABPAEC 350 180 1,235
ABPAEZ

Remarks Turn off the Power before installation or maintenance.

30 CAC Accessories
Electronic Thermostat

Accessory Name Electronic Thermostat

Accessory Model AQETC (Applicable only to Cooling Only model or Cooling Only model with
Name Electric Heater)

Functions • It provides ease of control.

SET/ROOM TEMPERATURE DISPLAY SET TEMPERATURE BUTTON (DECREASE)


1 9

SET TEMPERATURE BUTTON (INCREASE)


10

IR RECEIVER OPERATION MODE SELECT BUTTON


2 11
°C
Set Temp
COOL OPERATION LED ROOM TEMPERATURE DISPLAY BUTTON
3 Cool 12
FAN OPERATION LED FAN SELECT BUTTON
4 Fan Mode Mode Room(°C) 13
HEATER ON OPERATION LED
5 Heater TIMER BUTTON
14
FAN ON OPERATION LED
6 On Fan Timer
Fan
FAN AUTO OPERATION LED OPERATION ON/OFF BUTTON
7 Auto Select
15
TIMER LED On/Off
8 Timer

Picture SET/ROOM TEMPERATURE DISPLAY SET TEMPERATURE BUTTON (DECREASE)


1 9

SET TEMPERATURE BUTTON (INCREASE)


10

IR RECEIVER OPERATION MODE SELECT BUTTON


2 °C 11

COOL OPERATION LED ROOM TEMPERATURE DISPLAY BUTTON


3 12
FAN OPERATION LED FAN SELECT BUTTON
4 Mode 13
HEATER ON OPERATION LED
5 TIMER BUTTON
14
6 FAN ON OPERATION LED Fan
FAN AUTO OPERATION LED Select OPERATION ON/OFF BUTTON
7
15
TIMER LED
8 Timer

Note : Both the thermostat are same. Function of the keys are also same only dif-
ference between the two is marking in words and with symbol.

Electronic Thermostat........................1EA Hexagonal Nut .......................6EA


Parts Supplied Manual ..............................................1EA

• Applicable to Ducted Split (3~5RT Cooling only 50~60Hz) and


Applicable Models Single Package(60Hz 3~5RT Cooling only, 50Hz 3~4RT Cooling only) type.of air
conditioner.

CAC Accessories 31
Electronic Thermostat

Wiring Diagram :-

Main UNIT

AC230V(L)
1 1
AC230V(N)
2 2
THERMOSTAT
24V TRANS
AC24V(L) R R AC24V(L)
1 1 1
AC24V(N) C C AC24V(N)
2 2 2
FAN G G FAN
3 3 3 INDOOR FAN RELAY
COOL Y1 Y1 COOL
4 4 4 COMP1 RELAY

HEAT W1 W1 HEATER HEATER1 RELAY


5 5 5

Installation Procedure :-

Step1. Open the under plate carefully using a screw driver.

Front case

Th
el
ow
er
pa
rt
Lower carefully the
under plate and open Remote
it using a screw controller
Installation (When Cord Buried) driver, etc. body

Step 2. Fix the under plate on the switch box by locally sup-
plied screw.
Take care of deformation of under plate during fixing.

Face of wall
Upper notch
Step 3. Take out the electronic thermostat cord through the
Under plate
fittings & switch box. Remote
control unit
Screw
(Local supply)
Remote
control cord
Step 4. Connect the wiring to the terminal block of the ther- Lower notch
mostat. Switch box
(Local supply)

Step 5. Now, fix the thermostat on under plate.

32 CAC Accessories
Electronic Thermostat

Installation (When Cord Exposed)


Face of wall
Thermostat
cord Under plate
Step 2. Fix the under plate on the wall by self tapping
Tapping screw
screw. (Accessory)
Upper flange

Step 3. Round the cord as shown in the figure.


Remote
control unit

Step 4. Hook the thermostat unit on the under plate.

Fixing of cord : Cord


clamp

Step 5. Fix the cord clamps on the wall by Ø3 tapping screw


supplied locally.

Step 6. Fix the electronic thermostat cord.

1. Electronic thermostat should be installed at a place away from direct sunlight,


high humidity & direct supply of cold air.
2. Keep the electronic thermostat cord away from the refrigerant piping & the
Remarks drain piping.
3. Wiring must follow local and national code and installation should be done by
trained person.

CAC Accessories 33
Manual Hood

Accessory Name Manual Hood

Accessory Model
AKHDA
Name

Functions • To supply fresh air to maintain good IAQ.

Picture

- Manual Hood ..................................1EA Installation Manual ................1EA


Parts Supplied
- Screws M5 ....................................30EA

Applicable Models • Applicable to Single Package type of air conditioner.

The manual fresh air adjustment panel with the hood is designed to provide up to 25% percent outside air.
Once the adjustable panel is set and the hood is installed, they will allow a fix quantity of outside air to be
introduced into the conditioned space.

Table 1. Maximum Allowable Fresh Air for the Unit

Unit Max CFM Unit Max CFM


LK-06B0CH 625 LK-0880CH(HH) 650
LK-08B0CH 750 LK-1080CH(HH) 850
LK-09B0CH 850 LK-1380CH 1100
LK-10B0CH 1000 LK-1580CH(HH) 1325
LK-13B0CH 1250 LK-1880CH 1550
LK-15B0CH 1500 LK-2080CH 2000
LK-18B0CH 1750 LK-2580CH 2375
LK-20B0CH 2000
LK-25B0CH 2500

34 CAC Accessories
Manual Hood

Table 2. Accessory Hood Flow Rate Data

Returen Static -- inch W. G


Inches Open
-0.1 -0.2 -0.3 -0.4 -0.5 -0.6 -0.7 -0.8 -0.9 -1
1 80 159 195 221 277 292 352 383 378 438
2 197 296 361 415 498 511 586 636 656 717
3 318 432 528 610 720 731 819 890 933 997
4 431 569 694 804 941 950 1053 1143 1211 1276
5 471 680 830 959 1086 1174 1289 1404 1458 1573
6 511 791 965 1113 1231 1398 1525 1659 1705 1870
7 598 910 1095 1268 1422 1592 1731 1886 1958 2115
w/Open 707 1058 1258 1462 1661 1835 1989 2170 2275 2422

Note: Before utilizing CFM mentioned in the shaded area, refer to Table 1 for maximum allowable
fresh air for the unit.

Installation Procedure :- For CFM Opening


Refer to Table 1
1. Remove screws securing the fresh air adjustment
panel to the unit panel.
Fresh Air Damper
2. Adjust the amount of fresh air desired by changing
the position of the fresh air panel. refer to Table 2 to
determine the correct opening for the specified
amount of fresh air, based on the operating return
static pressure.

3. Secure the fresh air adjustment panel to the unit end Unit end panel
panel with 2 screws.
Figure 1
4. Using the provided screws, assemble the fresh air
hood, as illustrated in Figure 1.

5. Install the filter into the fresh air hood as illustrated


in Figure 2.

6. Install the fresh air hood onto end panel of the unit
using the 12 screws. (Installer can secure the hood
by punching on the unit end panel )

7. Turn on the power and start the supply fan.


Figure 2

CAC Accessories 35
Manual Hood

8. Measure the full load amps of the supply fan motor. If the
amperage exceeds the full load amps, system CFM may
be too high.
Make the necessary adjustments to lower the motor
amperage by ; readjusting the fresh air damper or adjust-
ing the fan RPM.

9. In case of installing a different type filter, you can assem-


ble it by provided screws through the holes in the side
panel as illustrated in Figure 3.

Dimensional Drawing:
Figure 3

Unit : Inch (mm)

A 24.98 (634.5)

B 28.11 (714)

C 25.91 (658)

D 19.35 (491.5)

Remarks • Turn off the Power before installation or maintenance.

36 CAC Accessories
RF Remote Control

Accessory Name RF Remote Control

Accessory Model
PQRFA0
Name

RF Receiver

Functions

• Anyway Control
- RF remmote controller can be possible to control the air-conditioner with
Boundless & through a wall. (It help you to control the unit anywhere you are!)
- Max reciving length is 20m

Picture

PQRFA0

- Remote Control.............................1EA
- RF Control.....................................1EA
Parts Supplied - Installation Manual .......................1EA
- Battery...........................................2EA

• Ceiling Concealed Duct type


- LBNH1861BL - LBNK4881BL - ABNW366KSA0
Applicable Models - LBNH2461BL - LBNL6081BL - ABNW426KSA0
- LBNS3061BL - LBNM7281BL - ABNW486KSA0
- LBNG3061BL - LBNM9081BL - ABNW606LTA0
- LBNK3661BL - LBNM1081BL
- LBNK4261BL

CAC Accessories 37
RF Remote Control

Installation
1. How to Install Password

1. Insert batteries

Remove the battery cover from the • Do not use


remote controller. rechargeable batteries
• Slide the cover according to the such batteries differ
arrow direction. from standard dry cells
in shape dimensions
Insert the two batteries. and per-formance.
• Be sure that the (+) and (-) • Romove the batteries
directions are correct. from the remote
• Be sure that both batteries are new. controller if the air
conditioner is not going
Re-attach the cover. to be used for some
• Slide it back into position. long time.

2. Set Password

Select the password.


The password can be selected from (0001-9999).
Enter your password in the remote controller.
The password can be selected using the
Up Down buttons as shown in the figure
next page example.

NOTE:
If you change the battery then you have to set the password again, in
condition of test operation mode (Push simultaneously hour +
room-temperature key over 3 seconds in wired remote controller.)

38 CAC Accessories
RF Remote Control

2. How to Install RF Control

1 First power off the Air - Conditioner.

2 Open the control box cover.

3 Insert the cable into CN-DISP of main P.C.B.

4 Close the control box cover.

5 Fix the receiver position at your desired location.

6 Insert the other part of cable into receiver.

7 Supply power to the Air - Conditioner.

8 Finally, You have to install password to operate RF remote controller.

Control terminal board


Control box A A view

Remote
1 control cord
Cord clamper

Connection cord between


the indoor unit and the
outdoor unit
1
Cable

Control box cover


(On which the Electric
Wiring Connection is put)

CAC Accessories 39
Air Guide

Accessory Name Air Guide

Accessory Model
PQAGA
Name

• It is an air guide that specially fits the Outdoor design.


• Air discharge can be changed by a simple installation.
• With one outdoor unit top discharge and front discharge
Functions are available simultaneously.

Picture

• Air Guide 1EA


Parts supplied

• Applicable to the outdoor unit of Multi V system.


Applicable Models

40 CAC Accessories
Elevation Grille Kit

Accessory Name Elevation Grille Kit

Cooling Only PT-CEE/F PT-CFE/F PT-CDE/F


Accessory Model
Name
Heat Pump PT-CEE/F PT-CFE/F PT-CDE/F

• Auto elevation grill will help easy clean and maintenance.


• With a Grill down button, front grill comes down.

• With a Grill up button, front grill goes up.


Functions
• With a grill stop button, front grill stops at the point.

• When the grill comes down, it does not affect the fan.

Picture

• Front panel assembly 1EA


Parts supplied • Screw 4EA
• Manual 1EA
• Remote controller 1EA

• Applicable to Ceiling Cassette type airconditioners.


Applicable Models

CAC Accessories 41
Branch Distributor

Accessory Name Branch Distributor

For R410A model For R22 model


Accessory Model
Name 2 indoor units PMBD3620 PMBD5420L

3 indoor units PMBD3630/7230 PMBD5430L

4 indoor units PMBD3640 PMBD5440L

• LG MPS Multi provides simple piping with using distributors


• Easy Installation with various distributors (for 2,3,4 Indoors)
Functions • Connecting with Flare and Nuts Installers can connect pipes to outdoor units,
indoor units, branches and distributors without brazing

Picture

(Shown PMBD3640)

• Factory Supplied : • Purchased Locally :


- BD(Banch Distributor) unit….1EA - Connecting wires
(H05VV, 4 wires, 0.75mm or 1.2mm)
- Hanger metal…………………4EA
- Installation Parts
Parts supplied - Screws ………………………12EA (Hanging bolts:4 x M10 orM8,
- Installation Manual…………. 1EA Nuts : 12, flat washers :8)
- Screws for wall-mounting : 6 x M5
- Insulation, Brass cap, Aluminum tape

• Applicable to Multi F DX, Tropical Multi system.


Applicable Models

42 CAC Accessories
Branch Distributor

Specifications :
R410A
Model PMBD3640 PMBD3630 PMBD3620 PMBD7230
Connectable Indoor Units Number of Indoor Units 1~4 1~3 1~2 1~3
Capacity Btu/h 7k/9k/12k/18k/24k 7k/9k/12k/18k/24k 7k/9k/12k/18k/24k 18k/24k/30k/36k
Casing color Paintingless Paintingless Paintingless Paintingless
Powre Source Ø1 , 50/60Hz ,220~240/220V Ø1 , 50/60Hz ,220~240/220V Ø1 , 50/60Hz ,220~240/220V Ø1 , 50/60Hz ,220~240/220V
Power Consumption W 10 10 10 10
Runing Current A 0.05 0.05 0.05 0.05
Dimensions W*H*D inch(mm) 11.9*5.6*9.9(302*143*252) 11.9*5.6*9.9(302*143*252) 11.9*5.6*9.9(302*143*252) 11.9*5.6*9.9(302*143*252)
Packing Dimension W*H*D inch(mm) 16.6*8.0*11.8(422*202*300) 16.6*8.0*11.8(422*202*300) 16.6*8.0*11.8(422*202*300) 16.6*8.0*11.8(422*202*300)
Net Weight kg 5.0 4.9 4.8 5.0
Connecting Cable Direction Indoor Unit No. * mm2 4*0.75 (Includes earth) 4*0.75 (Includes earth) 4*0.75 (Includes earth) 4*0.75 (Includes earth)
Direction Outdoor Unit No. * mm2 4*0.75 (Includes earth) 4*0.75 (Includes earth) 4*0.75 (Includes earth) 4*0.75 (Includes earth)
Piping Connection Liquid inch(mm) 3/8 (9.52) 3/8 (9.52) 3/8 (9.52) 3/8 (9.52)
(To Outdoor Unit) Gas inch(mm) 3/4(19.05) 3/4(19.05) 3/4(19.05) 3/4(19.05)
Piping Connection Liquid inch(mm) 1/4 (6.35)*4EA 1/4 (6.35)*3EA 1/4 (6.35)*2EA 1/4 (6.35)*3EA
(To Indoor Unit) Gas inch(mm) 3/8 (9.52)*4EA 3/8 (9.52)*3EA 3/8 (9.52)*2EA 1/2 (12.7), 3/8 (15.88)*2EA
Piping length m - - - -
Piping Elevation m - - - -
Drain hose Unusable
Heat Insulation Both Liquid and Gas pipes
Accessories Hanger EA 4 4 4 4
Screw EA 8 8 8 8
Manual EA 1 1 1 1

R22
Model PMBD5440L PMBD5430L PMBD5420L
Connectable Indoor Units 1~4 1~3 1~2
Combination(Min~Max.) Btu/h 12000~54000 12000~54000 12000~54000
Casing color Paintingless Paintingless Paintingless
Powre Source Ø1 , 50/60Hz ,220~240/220V Ø1 , 50/60Hz ,220~240/220V Ø1 , 50/60Hz ,220~240/220V
Power Consumption W 10 10 10
Runing Current A 0.05 0.05 0.05
Dimensions W*H*D inch(mm) 11.9*5.6*9.9(302*143*252) 11.9*5.6*9.9(302*143*252) 11.9*5.6*9.9(302*143*252)
Packing Dimension W*H*D inch(mm) 16.6*8.0*11.8(422*202*300) 16.6*8.0*11.8(422*202*300) 16.6*8.0*11.8(422*202*300)
Net Weight kg 5.0 4.9 4.8
Connecting Cable Direction Indoor Unit No. * mm2 4*0.75 (Includes earth) 4*0.75 (Includes earth) 4*0.75 (Includes earth)
Direction Outdoor Unit No. * mm2 4*0.75 (Includes earth) 4*0.75 (Includes earth) 4*0.75 (Includes earth)
Piping Conntcion Liquid inch(mm) 3/8 (9.52) 3/8 (9.52) 3/8 (9.52)
(To Outdoor Unit) Gas inch(mm) 3/4(19.05) 3/4(19.05) 3/4(19.05)
Piping Conntcion Liquid inch(mm) 1/4 (6.35)*4 1/4 (6.35)*3 1/4 (6.35)*2
(To Indoor Unit) Gas inch(mm) 1/2 (12.7)*4 1/2 (12.7)*3 1/2 (12.7)*2
Piping Length m - - -
Piping Elevation m - - -
Drain hose Unusable
Heat Insulation Both Liquid and Gas pipes
Accessories Hanger EA 4 4 4
Screw EA 8 8 8
Connector EA - - -
Manual EA 1 1 1

Note :
1. BD unit ↔ BD unit, Indoor Unit ↔ Indoor Unit : Max. Height - 10m
Set up the BD unit and Indoor Unit in 15m.
2. The piping connection must be suit the piping sizes of the indoor unit which will be connected.
(If need, use the connector which is included in the indoor unit)
3. The BD unit should be installed inside the building.

CAC Accessories 43
Branch Distributor

Installation Procedure :
• This unit may be installed suspended from the ceiling or mounted on the wall.
• This unit may only be installed horizontally , as shown in the diagram below.(Side B is facing up)
However, it may be freely installed in any direction forward or back, and to the sides.
• Be sure to leave a 600mm square opening for service and inspection as shown in the diagram below, for
both ceiling - suspended installation and wall-mounted installation.
• This unit "does not require drain treatment" as it uses internal foam treatment as low-pressure piping
insulation.
• Service direction is the side B and C
• The piping for the indoor unit may be led around in direction A
• The inclination of side B must be within ±5°C degrees forward or back or to the sides.

Refer to model
specifications
Refer to model
specifications
(298)

(337)
A Ø9.52
250

Ø19.05

245
Suspension bolt pitch.

Main Pipe
B
(36) 50 50 50 30 50
(150)
(38) 50

(111)

(56) 50 50 50 72 300 60
Branch Pipe Cover Control
C

Min 400 Min 400


(Servicing space)
Min 30

Min 300

Inspection opening

44 CAC Accessories
Branch Distributor

NOTICE :
• This unit has two different installation types:
(1) Ceiling-suspended type and (2) wall-mounted type.
• Choose the proper installation pattern according to the
location of installation.
• The installation location for printed wiring board can be
changed.
Follow the procedure specified in the "CONNECTING
THE WIRING" section to change the location.
(1) Ceiling-suspended type (2) Wall-mounted type

(1) Ceiling-suspended type Procedure


(1) Fix the fumished hanger metal with two screws.(4 locations in
total).
(2) Using an insert-hole-in- anchor, hang the hanging bolt.
(3) Install a hexagon nut and a flat washer (locally-procured)to
the hanging bolt as shown in the figure in the left, and ift the
main unit to hang on the hanger metal.
(4) After checking with a level that the unit is level, tighten the
hexagon nut.
* The tilt of the unit should be within ±5° in front/back and
left/right.

BD unit
Six-sided Nut 15.00
(M10 or M8)

Hanger metal

Flat washer

Hanging bolt
(M10 or M8)

(2) Wall-mounted type Procedure


(1) Fix the fumished hanger metal with two screws.
(3 locations in total).
(2) After checking with a level that the unit is level, fix the unit
with the furnished wood screws.
Screws(M5) * The tilt of the unit should be within ±5° in front/back and
(locally procude)
left/right.

CAUTIONS
• Once a screw-hole on the main unit has had a screw hammered in, make sure to either hammer it again
or cover it with alumium tape.(This is to prevent condensation)
• Be sure to install the unit with the ceiling-sie up.
• Do not install near bedrooms. the sound of refrigerant flowing through the piping may sometimes be
audible.

CAC Accessories 45
Branch Distributor

Connection of Wiring :
• Connect refrigerant pipes and connection wires to the appropriate ports maked with matching
alphabets (A, B and C) on this unit.
• Follow the instructions on the wiring nameplate to connect the connection wires of indoor/outdoor
units to terminal board numbers.(1, 2 and 3) Always fix each ground wire separately with a ground
screw.(See the figure below.)
• After completing the wiring, fix the outer coating of wires securely with wire clamps. The wire clamp
on indoor unit side is furnished. Follow the procedure below to install.
• Refer to the circuit diagram on the control cover inside outdoor unit.

NOTICE :
The terminal board numbers are arranged from top to bottom in order of 1, 2 and 3.

In Case of 3 rooms

Warning
Do not use tapped
wires, stand wires,
C room A extensioncords, or
starbust connections,
B room B as they may cause
overtheating, electrical
A room C shock, or fire.
CN-PWR

Connection wire for indoor units Connection wire for outdoor units
(H05VV, 4wires, 0.75mm) (H05RV, 4wires, 1.2mm)

(1) Remove the control cover. Loosen the two


screws, and slide the cover in the direction of
the arrow.

(3) Put in the cover in the direction of the arrow


then tighten the screws.

(2) Perform wiring with reference the wiring dia-


gram on a control cover of outdoor unit.
Allow 300 mm for the pulling-out section of
harness. Fix the wires completely with wire
clamps(4 locations).

46 CAC Accessories
Y Branch

Accessory Name Y Branch

Accessory Model ARBL052S ARBL102S ARBL202S ARBL302S


ARBL052L ARBL102L ARBL202L ARBL302L
Name
ARBL102G ARBL202M

Picture

Y Branch

- Y Banch(Gas side, Liquid side)….1EA


Parts supplied
- Installation Manual……..…………. 1EA

• Applicable to Multi V system.


Applicable Models

Pipe fitting :
Y branch
A To Outdoor Unit
A B B To Branch Piping or Indoor Unit

• Ensure that the branch pipes are attached horizontally or vertically (see the diagram below.)
Horizontal Facing Facing
plane downwards upwards

Within +/- 10

A
Viewed from point A
in direction of arrow

Within 3 Within 3

• There is no limitation on the joint mounting configuration.


• If the diameter of the refrigerant piping selected by the procedures described is different from the size
of the joint, the connecting section should be cut with a pipe cutter.
• Branch pipe should be insulated with the insulator in each kit. Tape
(field supply)

Liquid and Gas Insulator for


Insulator
pipe joints field piping
(included with kit)

CAC Accessories 47
Y Branch

Speciications :
Y branch pipe [unit:mm]

Models Gas pipe Liquid pipe


ø15.88 ø19.05 ø15.88 ø12.7 ø9.52 ø9.52 ø6.35

ARBL052S
ø12.7 ø9.52 ø6.35
ø15.88

ø25.4 ø19.05 ø19.05 ø12.7 ø12.7 ø9.52


ø15.88

ARBL052L
ø15.88 ø12.7 ø6.35
ø9.52

ø15.88 ø19.05 ø19.05 ø15.88 ø12.7 ø12.7 ø9.52

ARBL102S
ø12.7
ø15.88 ø12.7 ø9.52 ø6.35

ø28.58 ø25.4 ø28.58 ø25.4 ø15.88 ø12.7 ø15.88 ø12.7

ARBL102L ø19.05
ø19.05 ø9.52
ø12.7
ø15.88 ø12.7 ø9.52 ø6.35

ø28.58 ø25.4 ø28.58 ø25.4 ø15.88 ø12.7 ø9.52


ø12.7

ARBL102G ø19.05
ø19.05

ø15.88 ø12.7 ø12.7 ø9.52 ø6.35

ø38.1 ø31.8 ø19.05 ø15.88 ø19.05 ø15.88


ø38.1 ø31.8
ø28.58
ARBL202S ø12.7
ø12.7
ø25.4 ø19.05 ø15.88 ø12.7
ø9.52 ø6.35

ø38.1 ø31.8 ø19.05 ø15.88 ø19.05 ø15.88


ø38.1 ø31.8

ARBL202L ø28.58 ø12.7


ø28.58 ø25.4 ø19.05 ø12.7 ø9.52 ø6.35

ø38.1 ø31.8 ø38.1 ø28.58 ø19.05 ø15.88 ø19.05 ø15.88

ARBL202M ø25.4 ø12.7


ø28.58 ø12.7
ø28.58 ø25.4 ø19.05
ø12.7 ø9.52 ø6.35

ø44.5 ø38.1 ø22.2 ø19.05 ø22.2 ø19.05


ø44.5 ø38.1
ø31.8
ARBL302S ø12.7 ø15.88
ø25.4 ø19.05 ø15.88 ø12.7
ø9.52 ø6.35

ø44.5 ø38.1 ø38.1 ø31.8 ø19.05 ø15.88


ø22.2 ø19.05

ARBL302L ø28.58 ø12.7


ø31.8 ø25.4
ø28.58 ø15.88 ø12.7 ø9.52

ø44.5 ø38.1 ø38.1 ø31.8 ø22.2 ø19.05


ø22.2 ø19.05
ø15.88
ARBL302M ø28.58 ø15.88

ø31.8 ø25.4 ø12.7


ø28.58 ø22.2 ø19.05 ø15.88

48 CAC Accessories
Header

Accessory Name Header

4 branch 7 branch 10 branch


Accessory Model
Name ARBL054 ARBL057 ARBL1010
ARBL104 ARBL107 ARBL2010

Picture

Header Branch

- Header(Gas side, Liquid side)….1EA


Parts supplied - Installation Manual……..…………. 1EA

• Applicable to Multi V system.


Applicable Models

Pipe fitting :

A
Header A To outdoor unit
B To indoor unit

• The Indoor Unit having larger capacity must be


installed closer to than smaller one.
• If the diameter of the refrigerant piping selected
by the procedures described is different from
B the size of the joint, the connecting section
should be cut with a pipe cutter.

C Pipe cutter

• When the number of pipes to be connected is


smaller than the number of header branches,
install a cap to the unconnected branches.

CAC Accessories 49
Header

• When the number of Indoor Units to be connected to the branch pipes is less than the number of branch
pipes available for connection then cap pipes should be fitted to the surplus branches.

B
Piched pipe

• Fit branch pipe lie in a horizontal plane.

Horizontal plane

View from point B in the direction of the arrow

• Header should be insulated with the insulator in each kit.

Insulate the header using


the insulation
material attached to the
branch pipe kit
as shown in the figure.

• Joints between branch and pipe should be sealed with the tape included in each kit.
Tape

Insulator

Insulator of field pipe

• Any cap pipe should be insulated using the insulator provided with each kit and then taped as described
above.
Insulator for cap pipe

Cap pipe
Tape

50 CAC Accessories
Header

Specifications :
Header [unit:mm]

Models Gas pipe Liquid pipe

Ø12.7 Ø12.7

4 branch Ø6.35 Ø6.35


Ø15.88 Ø15.88
ARBL054 Ø9.52 Ø9.52

Ø19.05 Ø12.7

Ø12.7 Ø15.88
Ø12.7
Ø6.35 Ø9.52 Ø9.52
7 branch Ø6.35
Ø15.88
ARBL057
Ø12.7
Ø19.05

Ø12.7 Ø15.88
Ø9.52
Ø6.35 Ø6.35
Ø15.88 Ø19.05
4 branch
Ø9.52
ARBL104 Ø12.7
Ø28.58

Ø12.7 Ø15.88
Ø6.35 Ø9.52
Ø15.88 Ø6.35
Ø19.05
7 branch
Ø9.52
ARBL107 Ø28.58 Ø12.7

Ø12.7
Ø15.88 Ø6.35 Ø9.52 Ø6.35
Ø15.88 Ø19.05

10 branch
ARBL1010 Ø28.58 Ø9.52 Ø12.7

Ø12.7
Ø15.88 Ø9.52 Ø6.35
Ø15.88 Ø19.05 Ø6.35

10 branch Ø31.8 Ø15.88


Ø38.1 Ø19.05
ARBL2010 Ø9.52

CAC Accessories 51
Dry Contact module

Accessory Name Dry Contact module

Accessory Model PQDSA [Without case]


Name PQDSB [With case]

It toggles into On/OFF of Automatic Operation when pressing the Reservation Cancel button of the
Wireless Remote Controller in a series of 3 times within 3 minutes, with it facing to the main body.
At first, the Automatic Operation is not set.

1. When it is on the Automatic Operation,


• It(Air-conditioner) operates when the contact of controller is ON during its stop.
At this time, it is possible to stop/operate it by using controller.
• It stops when the contact of controller is OFF during its operation.
At this time, it is not possible to control with the controller as it stops and at once converts into the
Lock mode.
• RY1 becomes OFF during the operation and RY1 becomes OFF during the stop.
(However, RY1 can repeat its ON/OFF when generating error, depending on the model.)
Functions • RY2 becomes ON when generating error and RY2 becomes OFF in case of no error.

2. When it is not on the Automatic Operation,


• It(Air-conditioner) is possible its operation when the contact of controller is ON during its stop.
At this time, it is possible to stop/operate it by using controller.
• It stops when the contact of controller is OFF during its operation.
At this time, it is not possible to control with the controller as it stops and at once converts into the
Lock mode.
• RY1 becomes ON during the operation and RY1 becomes OFF during the stop.
(However, RY1 can repeat its ON/OFF when generating error, depending on the model.)
• RY2 becomes ON when generating error and RY2 becomes OFF in case of no error.

1
1 CN-POWER : AC 220V Connector
2 CN-CC : MAIN PCB Connector
3 CN_DRY (L) : DRY CONTROLLER Connector
Picture 2 4 CN_DRY ( SIG ) : DRY CONTROLLER Connector
5 CN_DRY (ERROR CHECK) : ERROR Check
Display Connector
6 CN_DRY( OPER STATE): Operation Display
Connector
3 4 5 6

Parts supplied • PQDSA kit ………………………… 1EA


• Installation Manual……..…………. 1EA

• Applicable to all LG airconditioners.


Applicable Models

52 CAC Accessories
Dry Contact module

Installation Procedure :

1 . Connect CN-CC with Main PCB by the cable(provided)


- Connection of Dry contact only
DRY CONTACT
SUB PCB

MAIN
PCB 4 4
3 3
CN-CC CN-CC 2 2
1 1

2 1
2 1 AC 220V

- Connection of Dry contact & LG Central Controller


Connection PCB DRY CONTACT
(6871A30056A) SUB PCB

MAIN
PCB 4 4
3 3
CN-CC CN-CC 2 2
1 1

2 1
2 1 AC 220V
BR1
C01A
OSC01B

IC01A

PI485 PCB : Special purchase for


L02D
L01D

S1
SWITCH
Central Control
(Ex : PHNFP14A0 or PSNFP14A0...)
L1 2 3 4
LED01G
LED02G
LED03G
LED1

ON
U03Y U04Y U02Y

TANS01Y

CN_COMM
C04Y

ZNR01Y
C03Y

2 . Connect CN_DRY with Control Unit .


(Fix SUB PCB into the proper location.)

- To apply power source through PCB - To apply power source from the outside
DRY CONTACT DRY CONTACT
SUB PCB SUB PCB

4 4 Operation Display 4 4 Operation Display


CN-CC 3 3 Error Check Display CN-CC 3 3 Error Check Display
RY1 RY2 2 2 RY1 RY2 2 2
1 1 Dry contact 1 1 Dry contact
Controller Controller
N L N L
2 1 2 1
2 1 2 1
INPUT AC 220V
AC 220V

CAC Accessories 53
20 Yoido-dong, Youngdungpo-gu, Yoido P.O.Box 355
Seoul 150-721, Korea
Phone: 3777-7969 Fax: 3777-5137/8
http://www.lge.com

Approvals:
EN ISO 9001
BS EN ISO 9001
ANSI/ASQC Q9001
KS A 9001

P/No.: 3828A20346H For continual product development, LG reserves the right to change specifications without notice.
©LG Electronics INC. Printed in Korea. December/2004