© 2021 Parker Hannifin Corporation. All rights reserved. Edition: October 2021/CAT/4083-5/UK
Zalsman/10-2021
Fluid & Gas Handling Hydraulics Pneumatics Process Control Sealing & Shielding
Key Markets Key Markets Key Markets Key Markets Key Markets
All the instruments meet the guidelines of the European Community (EU). Aerial lift Aerial lift Aerospace Alternative fuels Aerospace
Agriculture Agriculture Conveyor & material handling Biopharmaceuticals Chemical processing
It is confirmed that these products are approved acc. to following standards. Bulk chemical handling Alternative energy Factory automation Chemical & refining Consumer
Construction machinery Construction machinery Life science & medical Food & beverage Fluid power
Food & beverage Forestry Machine tools Marine & shipbuilding General industrial
Fuel & gas delivery Industrial machinery Packaging machinery Medical & dental Information technology
Industrial machinery Machine tools Transportation & automotive Microelectronics Life sciences
Life sciences Marine Nuclear Power Microelectronics
DIN/EN 61000-6-2 Marine
Mining
Material handling
Mining
Key Products Offshore oil exploration
Oil & gas
Military
Oil & gas
Air preparation
DIN/EN 61000-6-3 Mobile Oil & gas Brass fittings & valves Pharmaceuticals Power generation
Oil & gas Power generation Manifolds Power generation Renewable energy
Renewable energy Refuse vehicles Pneumatic accessories Pulp & paper Telecommunications
Renewable energy Steel Transportation
Note! Transportation
Truck hydraulics
Pneumatic actuators & grippers
Water/wastewater
Pneumatic valves & controls
Turf equipment
This document and other information from Parker Hannifin GmbH, provide product Key Products Quick disconnects Key Products
Check valves Rotary actuators Key Products Dynamic seals
or system options for further investigation by users having technical expertise. Before Connectors for low pressure Key Products Rubber & thermoplastic hose Analytical Instruments Elastomeric o-rings
& couplings
you select or use any product or system it is important that you analyse all aspects of fluid conveyance Accumulators
Cartridge valves Structural extrusions
Analytical sample conditioning
products & systems
Electro-medical instrument
design & assembly
Deep sea umbilicals
your application and review the information concerning the product or system in the Diagnostic equipment Electrohydraulic actuators Thermoplastic tubing & fittings Chemical injection fittings EMI shielding
Hose couplings Human machine interfaces Vacuum generators, cups & sensors & valves Extruded & precision-cut,
current product catalogue. Due to the variety of operating conditions and applications Industrial hose Hybrid drives Fluoropolymer chemical fabricated elastomeric seals
Hydraulic cylinders delivery fittings, valves
for these products or systems, the user, through his own analysis and testing, is solely Mooring systems &
power cables Hydraulic motors & pumps & pumps
High temperature metal seals
Homogeneous & inserted
responsible for making the final selection of the products and systems and assuring that PTFE hose & tubing Hydraulic systems High purity gas delivery
fittings, valves, regulators
elastomeric shapes
Quick couplings Hydraulic valves & controls Medical device fabrication
all performance and safety requirements of the application are met. The products are Rubber & thermoplastic hose Hydrostatic steering & digital flow controllers
& assembly
Integrated hydraulic circuits Industrial mass flow meters/
subject to change by Parker Hannifin GmbH at any time without notice. Tube fittings & adapters
Power take-offs controllers Metal & plastic retained
composite seals
Tubing & plastic fittings Permanent no-weld tube fittings
Power units Shielded optical windows
Rotary actuators Precision industrial regulators
Silicone tubing & extrusions
Technical subject to change. October 2021. Sensors & flow controllers
Thermal management
Process control double
block & bleeds Vibration dampening
Process control fittings, valves,
© Copyright 2021, Parker Hannifin Corporation. All Rights Reserved. regulators & manifold valves
Table of Contents
Page
3 Catalogue 4083/UK
Product overview
Measurement
SCP01 SCP02 SCP03
Pressure and tem-
perature sensors
Pressure sensor for Pressure sensor for Pressure sensor for mobile and
standard applications mobile hydraulics industrial applications
Page 12-15 Page 16-21 Page 22-26
Pressure sensor for Pressure sensor for Pressure switch with IO-Link
safety requirements press construction and
die-casting
Page 27-28 Page 29-30 Page 31-33
SCT-150
4 Catalogue 4083/UK
Product overview
Measurement, display and switching
SCPSDi SCPSD SCTSD SCTSD-L
The Controller Family
Pressure display and monitoring Temperature display and Temperature display and
monitoring level monitoring
Page 54-59 Page 60-65 Page 66-77 Page 78-81
Accessories
SCK cable SCA adapter Software ControllerWIN
41.5
L1
L4
S1
Ø14.5
ØD4
T1
T2
X1)
5 Catalogue 4083/UK
Selection guide pressure sensors
SCP01 SCP02 SCP03 SCP07 SCP08
Pressure and temperature sensors
6 Catalogue 4083/UK
Selection guide pressure controller
SCPSi SCPSD SCPSDi
7 Catalogue 4083/UK
Certified sensors and switches for
Pressure and temperature sensors
maritime applications
The products designed for maritime use meet the current international approvals:
The portfolio extends from pressure sensors to electronic switches with display for pressure / level / temperature.
Parker offers the chance to upgrade from mechanical to electronic measuring devices in the hydraulic system, with
the following advantages:
These certified products will enhance the safety and reliability of maritime hydraulic systems:
SCP01/ SCPSD / SCPSDi / SCLTSD / SCTSD-L
8 Catalogue 4083/UK
Pressure and temperature sensors
Device features
SensoControl® sensors feature long-term stability, inter- The SCP should be used when the pressure needs to be
ference immunity, a sturdy high-quality construction and a monitored reliably for long periods.
wide range of variants.
In this case the optimal sensor type can be selected from
The sensors are designed and manufactured in our own different product series according to the needs of the ap-
production facilities under established standards for the plication. Different connecting plugs, output signals and
industrial instrumentation and control systems. This allows connection threads are also available.
us to easily adapt them to customer requirements or to
critical applications. Temperature sensors
The SCT temperature sensor should be used when a tem-
We carefully consider the special requirements for auto-
perature signal is required.
mation and mobile hydraulics during the design phase.
So our SensoControl® sensors are ideally suitable for the These are characterised by their pressure resistance up
permanent series use in industrial and mobile applications. to 630 bar.
Pressure sensors
The housing and all parts of the pressure sensors that
touch the substances are manufactured from stainless
steel. This provides a large range of media tolerability. A
wide range of applications is possible due to the combi-
nation of high interference immunity and high resistance
to external influences (shock, vibration and temperature).
The application areas are varied: form process engineer-
ing test rigs, conveying and lifting equipment, mobile hy-
draulics, general machine construction, pneumatic con-
struction and hydraulic plant construction.
9 Catalogue 4083/UK
Pressure and temperature sensors
Overview
Pressure and temperature sensors
Range of use Pressure sensor for Pressure sensor for Pressure sensor for mobile and
standard applications mobile hydraulics industrial applications
Stainless steel measuring Stainless steel measuring Up to 1000 bar
cell cell G1/4 DIN 3852-11 (E)
Small design Small design Compact design
High burst pressure Stainless steel housing Long term stability
Resistant to pressure peaks High burst pressure Wide temperature range
Resistant to shock and ECE approval E1 -40...125°C (-40...257°F)
vibration High protection degree
Resistant to shock and
vibration
Application General machine construc- Mobile hydraulics Mobile hydraulic
tion Transport vehicles Transport vehicles
Injection-mould machines Conveyor vehicles Conveyor vehicles
Die-casting machines Commercial vehicles Commercial vehicles
Press construction Automotive technology Automotive technology
Test benches Brake systems Brake systems
Machine tool Oil pressure Oil pressure
Test equipment and tech- Test equipment and tech-
nology nology
Gearbox control Gearbox control
Order code SCP01-xxxx-xx-0x SCP02-xxx-xx-0xQ8 SCP03-xxx-xx-xx
Refer to page 12-15 16-21 22-26
SCP07
10 Catalogue 4083/UK
Pressure and temperature sensors
Range of use Pressure sensor for press con- IO-Link Pressure sensor or Measurement of pressure even
struction and die-casting switch under high operating pressures
11 Catalogue 4083/UK
SCP01 pressure sensor
Device features
Pressure and temperature sensors
Small design
Stainless steel measuring cell
Stainless steel housing
Shock and vibration proof
Wide range of compatible substances
High linearity
Long-term stability
Substance temperature -40...125 °C
(-40...257°F)
Pressure range up to 1000 bar (14,504 psi)
High burst pressure
Response time 1 ms
Eroding milling
Encapsulated electronics
The SCP01 pressure sensor was designed to meet indus- Typical application range
trial requirements and is used in control, regulating and General machine construction
monitoring systems. Injection-mould machines
The SCP01 is characterised by its compact design, high Die-casting machines
linearity and excellent interference immunity. It is suitable Press construction
for quick control solutions because of its fast response Test benches
speed. The compact stainless steel housing is good for Machine tool
harsh environmental conditions. All components which
come into contact with the substance are made from
stainless steel. This feature, combined with the welded,
thin-layer measuring cell, ensure optimal compatibility with
the substance.
In order to ensure an exact pressure measurement and
to avoid disturbances, an EDM hole is integrated. This
minimises the cavitation of air and dirt, thus preventing the
measuring cell from being influenced by pressure surges
and pressure peaks.
This product is ideal for permanent series usage in hydrau-
lic applications because of its long lifespan, high accuracy,
high reliability and sturdy stainless steel construction.
12 Catalogue 4083/UK
SCP01 pressure sensor
Technical data
Output signal 0...20 mA 2-wire 4...20 mA 4...20 mA 0.5...4.5 V (nom); 0...5 V; 1...6 V; 0...10 V
Auxiliary power V+ +9...36 VDC +9...36 VDC +9...36 VDC +14...36 VDC
Max. load ≥50...≤500 Ω ≥50...≤500 Ω ≥50...≤500 Ω ≥10 kΩ
(V+ - 9 V) / 20 mA (V+ - 9 V) / 20 mA (V+ - 9 V) / 20 mA
13 Catalogue 4083/UK
SCP01 pressure sensor
Pin assignment
Pressure and temperature sensors
14 Catalogue 4083/UK
SCP01 pressure sensor
SCP01-xxx-xx-07 Order code
Process connection
G 1/4“ BSPP 4
Connection plug
S1) = SW22 Circular connector M12x1 4-pole 7
Device connector DIN EN 175301-803 Form A 4-pole 6
SCP01-xxx-xx-0C Cevice plug industrial micro DIN 9.4 mm C
Output signal
4...20 mA (3-wire) 2
4...20 mA (2-wire) 3
0...10 V 4
S1) = SW22
Process connection
SAE 7/16 UNF Male O ring (Pn max. = 400 bar) 7
1/4 NPT (Pn max. = 600 bar) 5
Connecting plug
Circular connector M12x1 4-pole 7
Order quantity
Q8: Multiple of 50 pcs.
15 Catalogue 4083/UK
SCP02 pressure sensor
Device features
Pressure and temperature sensors
Small design
Stainless steel measuring cell
Stainless steel housing
Shock and vibration proof
High protection degree
E1 road approval
Substance temperature -40...150 °C
(-40...302°F)
Up to 1000 bar (14,504 psi)
1 ms
Up to 36-V wiring systems
The SCP02 was designed specifically for the use in mo- An EDM hole has been added so that you get a precise,
bile working machines. The SCP02 has e1-approval and interference-free pressure measurement. This minimises
is manufactured with state of the art production methods the cavitation of air and dirt, thus preventing the meas-
according to ISO/TS 16949. uring cell from being influenced by pressure surges and
pressure peaks.
The shock and vibration resistance, the EMC characteris-
tics, the power supply as well as the extended tempera-
Typical application range
ture range all were designed for this application type.
Mobile hydraulics
The SCP02 is suitable for quick control solutions because Transport vehicles
of its fast response speed. Conveyor vehicles
The compact stainless steel housing with the plastic con- Commercial vehicles
nector allows for use in harsh environmental conditions Automotive technology
such as those in mobile hydraulics. Brake systems
Oil pressure
The components which come into contact with the sub-
Test equipment and technology
stance are made from stainless steel (1.4548). This fea-
Gearbox control
ture, combined with the welded, thin-layer measuring cell,
ensures optimal compatibility with the substance.
16 Catalogue 4083/UK
SCP02 pressure sensor
Technical data
17 Catalogue 4083/UK
SCP02 pressure sensor
Pin assignment
Pressure and temperature sensors
DT04-4P
SCP02-xxx-xx-0D
2-wire 0...5 V; 1...6 V; 0.5...4.5 V
PIN
4...20 mA 0.5...4.5 V nom.; 0...10 V ratiometric
1 V+ V+ V+
2 P-signal 0 V / GND 0 V / GND
3 n.c.* P-signal P-signal
4 n.c.* n.c.* n.c.*
Material Plastic PBT-GF30 Ultradur B4300 G6 black
Protection class IP67
DT04-3P
SCP02-xxx-xx-0E
2 m fixed cable
SCP02-xxx-xx-00
2-wire 0...5 V; 1...6 V 0.5...4.5 V
4...20 mA 0.5...4.5 V nom.; 0...10 V ratiometric
bn V+ V+ V+
black n.c.* P-signal P-signal
blue P signal 0 V / GND 0 V / GND
Material Plastic PBT-GF30 Ultradur B4300 G6 black
Protection class IP69k
bn = brown-braun / bk = black-schwarz / bu = blue-blau
*n.c. = do not connect
18 Catalogue 4083/UK
SCP02 pressure sensor
Pin assignment
SCP02-xxx-xx-05 SCP02-xxx-xx-00
M12x1 Stationary cable (2 m)
19 Catalogue 4083/UK
SCP02 pressure sensor
SCP02-xxx-x4-0x SCP02-xxx-x8-0x SCP02-xxx-x5-0x
Pressure and temperature sensors
SCP02-xxx-x7-0x SCP02-xxx-x6-0x
SAE 04 - O-ring SAE 06 - O-ring
SCP02-xxx-xx-0x
M12x1
S1) = SW22
20 Catalogue 4083/UK
SCP02 pressure sensor
Order code Connection cable and single plug
Connecting plug
Stationary cable 1 m 0
Circular connector M12x1 5-pole 5
Device plug AMP Superseal A
Device plug DT04 4-pole D
Device plug DT04 3 pole E
Order quantity
Q8: Multiple of 50 pcs.
21 Catalogue 4083/UK
SCP03 pressure sensor
Device features
Pressure and temperature sensors
Monolithic design
No internal seal
No material mix
No weld seam
High media compatibility
Measuring range from -1 to 1000 bar
Negative pressure resistant
Many connections
The SCP03 is a pressure sensor for liquid and gaseous Typical application range
media. Mobile hydraulics
The digitally calibrated piezoresistive measuring cell de- Transport vehicles
tects negative pressures from -1 bar up to high pressures Conveyor vehicles
of 1000 bar. Commercial vehicles
Automotive technology
The pressure connection in contact with the medium has
Brake systems
a monolithic design. This eliminates the need for internal
Oil pressure
seals and weld seams. A mix of materials is avoided.
Test equipment and technology
The resulting low permeability in combination with the Gearbox control
stainless steel results in broad media resistance.
The compact stainless-steel housing allows space-saving
use, even in harsh environmental conditions. With its wide
range of pressure ranges, output signals and connectors,
the SCP03 can be used in industrial and mobile applica-
tions.
The packaging variant optimized for OEM’s is environmen-
tally friendly, cost-optimized and facilitates handling.
22 Catalogue 4083/UK
SCP03 pressure sensor
Technical data
SCP03- 004 010 016 025 035 040 060 100 250 400 500 600 1000
Pressure range 4 10 16 25 35 40 60 100 250 400 500 600 1000
Pn relative 0 ... bar / (psi) (58) (145) (232) (363) (500) (580) (870) (1450) (3626) (5800) (7300) (8702) (14,503)
Overload pressure Pmax
2 x Pn
DIN EN 60770-1 (bar)
relative
Burst pressure Pburst
DIN EN 60770-1 (bar) 3 x Pn
relative
23 Catalogue 4083/UK
SCP03 pressure sensor
Pin assignment
Pressure and temperature sensors
24 Catalogue 4083/UK
SCP03 pressure sensor
Pin assignment
SCP03-xxx-x6-0x SCP03-xxx-x7-0x
SAE 06 - O-ring SAE 04 - O-ring
25 Catalogue 4083/UK
SCP03 pressure sensor
Order code Order quantity
Pressure and temperature sensors
26 Catalogue 4083/UK
Pressure sensor SCP07
Device features
27 Catalogue 4083/UK
Pressure sensor SCP07
Technical data
Pressure and temperature sensors
28 Catalogue 4083/UK
Pressure sensor SCP08
Device features
29 Catalogue 4083/UK
Pressure sensor SCP08
Technical data Output signal 0...10 V 4...20 mA 2-wire
Pressure and temperature sensors
Conformity
CE yes
Overall Accuracy
22
54
@ RT *1 ≤0,5 %FS
86
@ -10°C...85°C *1 *2 ≤2 %FS 22
SW 22
@ -40...105°C * * 1 2
≤2,5 %FS
Long-term stability ≤0,2 %FS / year FKM seal SW 22
12
30 Catalogue 4083/UK
SCPSi pressure switch
Device features
The fully electronic pressure switch SCPSi is adjustable nation with the smart functions & setting options, opens
and free from susceptible mechanical and moving com- up new possibilities in machine design for the machine
ponents. designer, with considerable savings potential.
With its digital interface and smart functions, the SCPSi The compact stainless steel housing allows space-saving
iis future-proof for the increasing demands of automation use, even in harsh environments.
solutions.
The proven stainless steel measuring cell with the wide
The 2 switching outputs are individually and safely pa- pressure range (from -1 up to 600 bar) allows a wide
rameterized from the machine control system via the range of applications for liquid and gaseous media. The
standardized digital IO-Link interface (IEC 61131-9). This media-contacting pressure connection with the pressu-
replaces manual programming and the commissioning re measuring cell is monolithically manufactured from a
phase is considerably shortened. Devices can be repla- stainless steel without welds and sets new standards in
ced during operation without the need for reparameteriza- media compatibility and pressure resistance.
tion. In order to react promptly to machine status changes
The packaging variant optimized for OEM‘s is environ-
or process adjustments, the re-parameterization is carried
mentally friendly, cost-optimized and facilitates handling.
out during operation.
Application examples
As an alternative to the switching functions, diagnostic
values, process data and status messages are recorded Injection-mould machines
directly via IO-Link and enable subsequent more complex Tool-making machines
analyses. Via the integrated temperature measurement of Power packs
the pressure measuring cell, the media or ambient tempe- Special machine construction
rature is recorded. Replacement for mechanical pressure switches
31 Catalogue 4083/UK
SCPSi pressure switch
Technical data
Pressure and temperature sensors
SCPSi 001 004 010 025 060 100 250 400 600
Pressure range Pn bar -1...1 -1...4 -1...10 -1...25 0...60 0...100 0...250 0...400 0...600
vacuum tight / relative Pn (psi) (-14...14) (-14...58) (14...145) (-14...362) (0...870) (0...1450) (0...3625) (0...5801) (0...8702)
Overload pressure bar 6 10 030 80 200 300 750 1200 1400
relative Pmax (psi) (87) (145) (435) (1160) (2900) (4351) (10877) (17404) (20305)
Burst pressure bar 9 15 100 150 500 800 1000 2000 2200
relative Pburst (psi) (130) (217) (1450) (2175) (7251) (11603) (14503) (29007) (31908)
1.4542 (17-4PH);
Wetted parts Monolitisch 316L; FKM
1.4548; FKM
Set point SP Range 1 - 100 %
Reset point rP Range 0 - 99 %
Steps / Incremental mbar 0,1 1 1 1 10 10 10 100 100
Smallest hysteresis
bar 0,001 0,01 0,01 0,01 0,1 0,1 0,1 1 1
(SP-rP) & (FH-FL)
32 Catalogue 4083/UK
SCPSi pressure switch
Order code
Druckbereich
0…001 bar 001
0…004 bar 004
0…010 bar 010
0…025 bar 025
0…060 bar 060
0…100 bar 100
0…250 bar 250
0…400 bar 400
0…600 bar 600
33 Catalogue 4083/UK
SCT-150 temperature sensor
Device features
Pressure and temperature sensors
34 Catalogue 4083/UK
SCT-150 temperature sensor
Technical data SCT-150-xx-07
Pin assignment
Cable Assignment
1 V+
2 T-signal L1) = 61
3 0 V / GND X1) = ED seal
4 n.c.*
SCT-150-14-07
*n.c. = do not connect
M10x1
Order code
Temperature sensor G1/4 SCT-150-41-07
Temperature sensor M10x1 SCT-150-14-07
X1) = O-ring
35 Catalogue 4083/UK
Volumetric flow rate sensors
Device features
Different measurement techniques
Quick
Not dependent on viscosity
Without loss
Many measurement ranges
Analogue output signal
M12 connecting plug
24 VDC
Volumetric flow rate sensors
36 Catalogue 4083/UK
Volumetric flow rate sensors
Overview
SCQ SCFT SCVF
Range of use For quick Low loss measuring of volume Measures different substances
flow changes flow Measures lower volume flows
Measures in both directions (leakage measurements)
Response speed Response speed Very wide measurement
≤ 2 ms ≤ 50 ms range
Reverse operation Many measurement ranges Not dependent on
Wide viscosity range Low flow resistance viscosity
Compact size Up to 800 l/min Up to 400 bar (6092 psi)
37 Catalogue 4083/UK
SCQ flow meter
Device features
Measurement principle Spring/piston
principle
Response time ≤ 2 ms
Measurement in both directions
Wide viscosity range
Compact design
Withstands pressures up to 420 bar
(6092 psi)
Volumetric flow rate sensors
Function Application
The piston (K) is moved due to a flow from A to B or from When working with high-pressure hydraulics, it is very im-
B to A. In the idle state, the spring (F) and the piston (K) portant to be able to quickly detect the flow rate.
are in equilibrium. The delta (S) is proportional to the flow
Installation with a connection block permits the combined
and is converted to a value through the built-in electronics.
measurement of p, T and Q. Rapid assembly of the SCQs
Through the change in direction of the piston (B to A), the
is achieved with an in-line adaptor for tube or hose instal-
flow direction can be indicated. (e.g. -45.8 l/min) The reac-
lation. Use under extreme conditions (such as high load
tion time of the piston movement is less than 2 ms.
changes or rapid pressure increases) is possible because
of the sturdy construction.
The SCQ is the perfect solution when recording highly dy-
namic volume flow changes. Rapid load changes, which
can cause damage for example in valves and pumps, can
be safely detected. Due to its unique measurement pro-
cess, the SCQ can capture volume flow in both directions.
38 Catalogue 4083/UK
SCQ flow meter
Technical data
SCQ- 150
Measuring range QN -150...+150 l/min
Qmax -165...+165 l/min
Substance connection M42 (NG16)
Weight (g) 1050
Pin assignment
M12x1; 4-pole
PIN Assignment
1 V+
2 Q signal
3 0 V / GND
4 –
39 Catalogue 4083/UK
SCQ flow meter
Screw plug hole and pressure-drop curve SCQ-150
30 Nm torque
50x30
77
SW27
hex27
Volumetric flow rate sensors
X1)
ca. 97
X2)
40 Catalogue 4083/UK
SCQ flow meter
SCAQ-GI-R1/2 Order code
100
SCQ-150 (-150 to +150 l/min) SCQ-150-10-07
M12x1, 4-pole; connecting plug; IP67
0 to 20 mA; -150...+150 l/min
36
Accessories SCQ-150
Connector block SCAQ-150
G3/4 BSPP inner (A-B) and M42 inner
With screw plug:
M42 outer and
SCAQ-150
G3/4 BSPP outer (A-B)
80
30 120
Spare parts
10 68 42 Spacer ring for SCQ-060 SC-910
Seal kit for SCQ-060 SC-911
Seal kit for SCQ-150 SC-912
8.5
60
80
A B
M8 15 10
Connection cable, assembled SCK-400-xx-xx
44 20 tief 42.5 55
(open cable end)
0.5
G3/4 G1/4
Connecting plug
ø34 ø16
M12 cable jack; straight 45
M12 cable jack; 90° angled 55
Single connector
M12 cable jack; straight SCK-145
M12 cable jack; 90° angled SCK-155
41 Catalogue 4083/UK
SCFT measurement turbine
Device features
Measurement principle: Turbine
Response speed ≤ 50 ms
Measurement range from 1 to 800 l/min
Low flow resistance
Suitable for reverse operation
Built-in pressure and temperature ports
Volumetric flow rate sensors
Function
The turbine wheel is driven by the oil flow. The generated
frequencies are processed through the digital electronics
and influences from the disturbing flow effects are com-
Output
pensated for. Because of the low flow resistance QR, the
hydraulic circuit operates with very low losses.
Reverse operation is also possible because of the special
vane (winged) design - so the turbine can be operated in
Magnetic both directions.
Flow recording
The turbine is fitted with an EMA-3 screw coupling for
Axial turbine measuring pressure. Oil temperature can measured di-
rectly in the oil flow of the turbine by connecting the tem-
perature sensor (SCT-150). This provides all important
measurements at the installation location.
Application
The SCFT is the ideal solution if the volumetric flow rate
Rotation needs to be recorded loss-free across a wide flow range
(up to 800 l/min.).
42 Catalogue 4083/UK
SCFT measurement turbine
Technical data
SCFT- 015 060 150 300 600 800
Flow measuring range
1...15 3...60 5...150 8...300 15...600 20...800
Qn (l/min)
Accuracy (± %)
± 1 % FS ± 1 % IR ± 1 % IR ± 1 % IR ± 1 % IR ± 1 % IR
FS/IR @ 21cSt.
Operating pressure Pn 350 350 350 350 290 400
bar / (psi) (5076) (5076) (5076) (5076) (4206) (5801)
Ports (A - B) G1/2 BSPP G3/4 BSPP G3/4 BSPP G1 BSPP G1 1/4 BSPP G1 7/8 UNF
Pressure drop
1.5 1.5 1.5 4 4 5
ΔP (bar) @ (FS)
Weight (g) 700 1600 1600 1700 2700 5000
FS = Full Scale
IR = Indicated Reading
Pin assignment
M12x1; 5-pole
PIN Assignment
1 V+
2 n.c.
3 Q signal
4 n.c.*
5 0 V / GND
43 Catalogue 4083/UK
SCFT measurement turbine
E
FLOW
C
A
B
Volumetric flow rate sensors
P Q
N
M
S
44 Catalogue 4083/UK
SCFT measurement turbine
Order code
SCFT
M12x1, 5-pole; connecting plug; IP66
4...20 mA (3-wire)
1...15 l/min SCFT-015-22-07
3...60 l/min SCFT-060-22-07
5...150 l/min SCFT-150-22-07
8...300 l/min SCFT-300-22-07
15...600 l/min SCFT-600-22-07
20...800 l/min SCFT-800-22-07
Connecting plug
M12 cable jack; straight 45
M12 cable jack; 90° angled 55
Single connector
M12 cable jack; straight SCK-145
M12 cable jack; 90° angled SCK-155
45 Catalogue 4083/UK
SCVF volume counter
Device features
Measurement principle: Volume/geared
counter
Eight measurement ranges from
0.01 - 2 to 1 - 300 l/min
Accuracy ± 0.5 % FS
Withstands pressures up to 400 bar
(5802 psi)
High viscosity range
Low noise
Volumetric flow rate sensors
Function
The SCVF geared counter functions as a volume flow me-
ter. A very precisely crafted pair of geared wheels is driven
by the fluid flow.
The SCVF works over a wide viscosity range. Different
seals permit usage in many different applications.
Applications
Due to the wide viscosity range, any liquid can be meas-
ured that can be pumped and has a certain degree of
lubricating capability.
Brake fluid (EPDM seal)
Skydrol
Mineral oils
Hydraulic oil and
Grease
The SCVF is the ideal solution when carrying out precise
flow rate measurements over a wide viscosity range.
46 Catalogue 4083/UK
SCVF volume counter
Technical data
SCVF- 002 004 015 040 060 080 150 300
Flow measuring range (l/ 0.01...2.0 0.02...4.0 0.2...15 0.4...40 0.4...60 0.4...80 0.6...150 1.0...300
min)
Pressure range PN bar 400 315 400 400 400 400 315 315
/ (psi) (5802) (4569) (5802) (5802) (5802) (5802) (4569) (4569)
Overload pressure PO bar 480 400 480 480 480 480 350 350
/ (psi) (6962) (5802) (6962) (6962) (6962) (6962) (5076) (5076)
Connection G3/8 G3/8 G3/8 G1/2 G1/2 G1/2 G1 G1
BSPP BSPP BSPP BSPP BSPP BSPP BSPP BSPP
Sound level dB (A) < 60 < 60 < 60 < 70 < 70 < 70 < 70 < 72
Resolution (pulses / litre) 40,000 25,000 4082 965 965 965 333.33 191
Pin assignment
M12x1; 4-pole
PIN Assignment
1 V+
2 Q-signal
3 0 V / GND
4 –
47 Catalogue 4083/UK
SCVF volume counter
Technical data
Δp [bar]
Volumetric flow rate sensors
Q [l/min] Q [l/min]
Δp [bar]
Q [l/min] Q [l/min]
Q [l/min] Q [l/min]
Δp = pressure loss
48 Catalogue 4083/UK
SCVF volume counter
J D
42
M12x1
G
F
X1
57 X2
P
58
L
L
K øN
A K
49 Catalogue 4083/UK
SCVF volume counter
Dimensioned drawings connection plate
A
E
K
øH
J
P
C
M
B
F
L
R
øN
øG
Volumetric flow rate sensors
f
c
øe
ød
øe
Type kg A B C E F øG øH J K L M øN P R c ød f
BSPP
SCVF-002
SCVF-004 1.8 85 90 35 65 76 7 11 7 70 40 20 6.5 M6/t = 14 17 0.7 25 G3/8 13
SCVF-015
SCVF-040
SCVF-060 2.9 100 120 37 80 106 7 11 7 84 72 35 12 M8/t = 18 17.5 0.7 29 G 1/2 15
SCVF-080
SCVF-150
14 160 165 80 140 145 9 15 9 46 95 50 25 M12/t = 24 28 1 42 G1 19
SCVF-300
All measurements in mm
50 Catalogue 4083/UK
SCVF volume counter
Order code
SCVF
M12x1, 4-pole; connecting plug; IP65; incl. connection plate
0...20 mA
0.01...2 l/min SCVF-002-10-07
0.02...4 l/min SCVF-004-10-07
0.2...15 l/min SCVF-015-10-07
0.4...40 l/min SCVF-040-10-07
0.4...60 l/min SCVF-060-10-07
0.4...80 l/min SCVF-080-10-07
0.6...150 l/min SCVF-150-10-07
1...300 l/min SCVF-300-10-07
Connecting plug
M12 cable jack; straight 45
M12 cable jack; 90° angled 55
Single connector
M12 cable jack; straight SCK-145
M12 cable jack; 90° angled SCK-155
51 Catalogue 4083/UK
The Controller Family
Device features
Large display
Freely adjustable
Rugged metal construction
Compact size
Long-term stability
Dependable
Immune to interference
This controller is used in control, regulation or monitoring All control devices have a compact and pivoting metal
systems where switching signals or analogue signals are housing so that they can be mounted optimally under ad-
used or a display is required. verse installation conditions. The large display can always
be perfectly positioned so that it is easy to read even at
The controller can replace the following:
longer distances.
Mechanical switches
Both of the switching outputs can be set individually either
Mechanical displays
as NO or NC. They also both have hysteresis and the win-
(pressure gauges, thermometers, inspection glass)
dow functions. Therefore the on and off switching values
Sensors
as well as delay times (attenuation) for each of the switch-
All the above mentioned functions can be combined in ing points can be chosen freely.
one device.
Thanks to these easy switching functions, intelligent ad-
justments can be set which are normally not possible us-
ing a mechanical switch. Therefore, many switches can be
replaced with one controller.
The controllers offer good practical characteristics com-
bined with diverse mounting and setting options.
Because of its compact design, long lifespan and high
functionality, this controller is ideal for the permanent se-
The Controller Family
52 Catalogue 4083/UK
The Controller Family
Overview
SCPSDi SCPSD SCTSD SCTSD-L
Range of use Pressure display and monitoring Temperature display and Temperature display and
monitoring level monitoring
Compact size Compact size Temperature display Temperature display
Resistant to pres- Resistant to pres- Modular design Fixed level contacts
sure peaks sure peaks Suitable for control
Resistant to shock Resistant to shock panel and tank con-
and vibration and vibration struction
IO link High pressure ver-
sion
Applications Test benches
Processing equipment
Conveying and lifting equipment
General machine construction
Pneumatic plant construction
Hydraulic plant construction
Range of use Level indication and monitoring Level/temperature display and monitoring
53 Catalogue 4083/UK
SCPSDi PressureController
Device features
IO LINK Compact size
VDMA menu Rugged
ECO mode MPa, bar, PSI
> 360° pivot function Metal housing
180° reversible display Installation width 35 mm
Analogue output V/mA Installation height 78 mm
Operator safety improved
with LOCK
1234
I/O
The key features of the SCPSDi are the innovative design Easy to use
and the resulting installation options combined with the
The terminology and symbols used, as well as the menu
diverse connection possibilities.
structure used for setting parameters can be easily
These unique functions make the SCPSDi ideal for perma- browsed using the buttons in accordance with the VDMA
nent series use in industrial applications. standard journal (VDMA 24574-1) or automatically using
IO Link.
Innovative construction design
The external-thread pressure port is stop-free and can be Universal
turned independently of the housing. So you can install Each switching output can be adjusted individually:
the pressure connection without turning the housing. The
NO/NC contact
small size means that it can easily be installed in cramped
On/off switching pressures
quarters. After the installation, the housing can be fully ro-
Delay times
tated over 360° with no stop. It also locks into position
Hysteresis / window function
while under pressure.
The optional analogue output is switchable between 0/4 to
For the internal-thread pressure port, all components that
20 mA and 0 to 10 V. An unintentional parameter change
The Controller Family
54 Catalogue 4083/UK
SCPSDi PressureController
Device features Housing
Metal housing
No movable elements,
therefore wear-free
Display Not sensitive to external environ-
Active-lit LED display ment
Pressure display Waterproof IP67
Units are displayed Rugged
Bar / PSI / MPa
Adjustments and settings
Switch status is shown
180° rotation for top mount VDMA menu navigation
ECO mode* Two large buttons
LOCK function**
Design
No moveable seals M12
Few housing elements Threaded metal connection
No mixing of materials The plug cannot be over-rotated
Ergonomic or broken off
Minimal surface area for dirt VDMA-compliant assignment of
Compact size pins
Plug in the front IO link
Compact installation dimensions DESINA
Sloped display 2 switching outputs
Switchable analogue output
Measuring component 0...20 mA
Hermetically sealed and 4...20 mA
welded stainless steel membrane 0...10 V
Zero-point stability Excellent interference immunity
Long-term stability
No wear and tear
Excellent pressure resistance
Up to a nominal pressure of 600 bar
Inner thread
All components that come into
Innovative construction of external threads
contact with the substance
The external-thread pressure port is stop-free being measured are made from
and can be turned independently of the hous- stainless steel
ing. So you can install the pressure connection No internal sealing components
without turning the housing. Wide range of compatible sub-
The housing can be set in any direction for opti-
The Controller Family
stances
mal cable routing and locks under pressure. Resistant against corrosive
Self-contained housing and aggressive substances
No force is exerted on the measuring component
during installation
Stainless steel
BSPP/UNF/NPT * E CO mode (activated via menu): pressure switch is run with minimum power in
this mode
NBR sealing ** LOCK function (button lock): Prevents accidental changing of the pressure
switch parameters
55 Catalogue 4083/UK
SCPSDi PressureController
Technical data
SCPSDi- 010 016 025 060 100 250 400 600
Pressure range Pn, relative bar / (psi)
Adjusting range RSP...SP -1...10 -1...16 -1...25 0...60 0...100 0...250 0...400 0...600
(Lowest reset switch point ... highest (-14.5...145) (-14.5...232) (-14.5...363) (0...870) (0...1450) (0...3625) (0...5802) (0...8702)
switch point)
Overload pressure * Pmax 2 x Pn
Burst pressure ** Pburst 3 x Pn
Display resolution 0.01 0.01 0.01 0.1 0.1 1 1 1
Increment size bar / (psi) (0.15) (0.15) (0.15) (1.45) (1.45) (14.5) (14.5) (14.5)
Smallest adjustable difference between 0.01 0.01 0.01 0.1 0.1 1 1 1
SP and RSP (SP-RSP) bar / (psi) (0.15) (0.15) (0.15) (1.45) (1.45) (14.5) (14.5) (14.5)
* DIN EN 60770-1
** DIN 16086
Switch point accuracy ± 0.5% FS typ.; +/- 1% FS max. Switching output 2 High-side (PNP)*
Optional
Display accuracy ± 0.5% FS +/- 1 digit typ.
± 1% FS +/- 1 digit max. Switching current: max. 500 mA
max.
* Including non-linearity, hysteresis, zero-point and full-scale deviations (corres- IO Link Specification V1.0 PNO Order
ponds to measurement deviations according to IEC 61298-2) No. 2.802
Analogue output 4...20 mA, 0...20 mA,
Response speed
0...10 V
Switching output ≤ 10 ms *see ECN15003
Analogue output ≤ 10 ms
56 Catalogue 4083/UK
SCPSDi PressureController
Technical data Pin assignment
Housing M12x1; 4-pole
Rotating > 360° PIN Assignment
Readability of the display viewing angle can be rotated 1 V+
180°
Configurable (programming) 2 S2 out / analogue
57 Catalogue 4083/UK
SCPSDi PressureController
SCPSDi-xxx-xx-17 SCPSDi-xxx-xx-27
S1) SW22
SCSD-S22
The Controller Family
58 Catalogue 4083/UK
SCPSDi PressureController
SCPSDi-xxx-x4-17 Order code
G1/4ED
SCPSDi 2 switching outputs; SCPSDi-xxx-04-x7-
SCPSDi 2 switching outputs Marine; SCPSDi-xxx-04-x7-MA
L1) 77.5 (approved by DNV/GL/ABS)
L2) 35 without analogue output,
G 1/4, M12x1; 4-pole
X1) ED seal
1 switching output; SCPSDi-xxx-14-x7
1 switching output Marine; SCPSDi-xxx-14-x7-MA
(approved by DNV/GL/ABS)
switchable analogue output,
G 1/4, M12x1; 4-pole
Pressure range
SCPSDi-xxx-x4-27 010 010
016 016
G1/4 025 025
060 060
100 100
250 250
400 400
600 600
Version
Outer thread 1
Inner thread 2
Connecting plug
M12 cable jack; straight 45
M12 cable jack; 90° angled 55
Single connector
M12 cable jack; straight SCK-145
The Controller Family
Accessories:
Securing clamp SCSD-S27
59 Catalogue 4083/UK
SCPSD PressureController
Device features
Compact size High protection class
Rugged Many variants
Dependable Pivoting
Easily operable Analogue output
Long-term stability Password
Excellent interference im- MPa, bar, PSI
munity
Metal housing
1234
The PressureController combines the functions of a The analogue output is individually adjustable
pressure switch, a pressure sensor and a display de-
0/4...20 mA switchable
vice.
Starting pressure selectable
Pressure gauge (manometer) End pressure selectable
Switching outputs
Analogue signal Reliable and safe
The PressureController is easy to operate, has a compact The pressure is recorded with a long term stable measur-
design and is very reliable. The PressureController fea- ing cell. A functional error is signalled and can be pro-
tures excellent technical specifications, optimal pressure cessed further according to DESINA. Parameters can be
management and a wide variety of installation options. password protected to avoid unauthorised changes.
This makes it perfect for permanent series use in industrial
applications. Rugged
The housing is made of metal and is resistant to mois-
Easy to use ture, shock and vibrations. The electronics are protected
The parameters are set using the keys or over a program- against reverse polarity, over-voltage and short-circuits.
ming module.
Everything at a glance
High functionality The large illuminated display can be read from long dis-
Each switching output can be adjusted individually: tances. The pressures can be displayed in MPa, bar or
PSI.
NO/NC contact
On/off switching pressures Optimal installation possibilities
The Controller Family
Delay times
The SCPSD is ideal for installation under critical conditions
Hysteresis / window function
because of its compact design and excellent interference im-
Attenuation
munity. The display is always easy to read because the
Thanks to these easy switching functions, intelligent ad- housing can be positioned as needed.
justments can be set which are normally not possible us-
ing a mechanical switch. Therefore, many switches can be Universal
replaced with one controller. Diverse versions are available for the many different ap-
plications.
60 Catalogue 4083/UK
SCPSD PressureController
Device features
Optical interface
Switch status is shown
I II
SensoControl
Everything at a glance
Sloped display
Digital display
bar/PSI
Large
Illuminated Easy to use
Display 3 large buttons
UNIT
PSI/bar/Mpa Display of the unit
Current pressure
Minimum pressure
Maximum pressure Rugged
Switching points Metal housing
Waterproof
Variable installation
Excellent interference immunity
Compact size
Vibration proof
290° pivotable
Shock proof
Pressure port
Stainless steel
Long term stable measuring cell
Wide range of compatible sub- Tube clamp
stances Safe installation with the sturdy
SCSD-S27 clamp
Thread
Inner thread
Programming module
Adjustable through
ControllerWIN Software
Outer thread
The Controller Family
61 Catalogue 4083/UK
SCPSD PressureController
Technical data
SCPSD- 004 010 016 060 100 250 400 600
Pressure range Pn relative
-1...4 -1...10 -1...16 0...60 0...100 0...250 0...400 0...600
bar / (psi)
(-14.5...58) (-14.5...145) (-14.5...232) (0...870) (0...1450) (0...3626) (0...5802) (0...8702)
Adjusting range RSP...SP
Overload pressure 10 20 40 120 200 500 800 1200
Pn bar / (psi) (145) (290) (580) (1740) (2400) (7521) (11,603) (17,405)
Burst pressure Pn bar / (psi) 12 25 50 550 800 1200 1700 2200
(174) (363) (725) (7977) (11,603) (17,405) (24,656) (31,908)
Display resolution bar / (psi) 0.01 0.01 0.01 0.1 0.1 1 1 1
(0.15) (0.15) (0.15) (1.45) (1.45) (14.5) (14.5) (14.5)
Smallest adjustable differ-
0.03 0.06 0.09 0.3 0.6 2 3 3
ence between SP and RSP
(0.44) (0.87) (1.31) (4.35) (8.7) (29) (43.5) (43.5)
(SP-RSP) bar / (psi)
Measuring component Ceramic Thin film DMS
Parts in contact with Stainless steel 1.4404; Stainless steel 1.4404; 1.4542
substances Ceramic AL2O3; NBR
Temperature drift ± 0.02 % FS/°K type (at -20...+85 Material Painted zinc die cast Z 410
°C) Foil material Polyester
± 0.03 % FS/°K max. Display 4-digit 7-segment LED;
Long-term stability ± 0.2 % FS/a red; digit height 9 mm
Repeat accuracy ± 0.25 % FS Protection degree IP67 DIN EN 60529;
Switching point accuracy ± 0.5 % FS typ.; ± 1 % FS max.
Display accuracy ± 0.5 % FS type ± 1 Digit
± 1 % FS max. ± 1 Digit
Response speed
The Controller Family
Switching output ≤ 10 ms
Analogue output ≤ 10 ms
62 Catalogue 4083/UK
SCPSD PressureController
Technical data Pin assignment
Ambient conditions SCPSD-xxx-14-x7
Ambient temperature -20...+85 °C (-4...185°F) 1 switching and 1 analogue output
range
M12x1; 4-pole
Storage temperature -40...+100 °C (-40...212°F)
range PIN Assignment
Vibration resistance 20 g; 10...500 Hz 1 V+
IEC60068-2-6** 2 Analogue out
Shock resistance 50 g; 11 ms 3 0 V / GND
IEC60068-2-29**
4 S1 out
EM compatibility
Disturbance emissions EN 61000-6-3
Resistance to interference EN 61000-6-2
Outputs
Switching outputs Two MOSFET high-side switches SCPSD-xxx-04-x7
(PNP) 2 switching outputs;
Contact functions NO / NC contact; M12x1; 4-pole
window / hysteresis;
function freely adjustable PIN Assignment
Switching voltage V+ -1.5 VDC 1 V+
Switching current max. 0.5 A per switch 2 S2 out
Short-circuit current 2.4 A per switch 3 0 V / GND
Analogue output 0/4...20 mA; programmable; 4 S1 out
freely scalable;
RL ≤ (Supply voltage - 8 V)/
20 mA (≤ 500 Ω)
* different sealing material (FKM, EPDM etc.) upon request
** does not apply for version DIN EN 175301-803 Form A (old DIN43650)
SCPSD-xxx-14-x5
2 switching outputs; 1 analogue output;
M12x1; 5-pole
Information about selecting the pressure range PIN Assignment
The following parameters are relevant when working with 1 V+
pressure switches: 2 S2 out
System pressure 3 0 V / GND
Switching point pressure 4 S1 out
5 Analogue out
Since a 400-bar (5802 psi) pressure switch has a com-
parable resolution (of 1 bar, 14.5 psi) as that of a 600-bar
(8702 psi) pressure switch (also 1 bar), it is possible to use
a 600-bar (8702 psi) pressure switch even when there is a
The Controller Family
63 Catalogue 4083/UK
SCPSD PressureController
Outer thread Inner thread
SCPSD-xxx-x4-1x SCPSD-xxx-x4-2x
Up to 10 bar (145 psi) From 16 bar (232 psi)
39.5 39.5
39.5
I II I II
SensoControl SensoControl
I II
SensoControl
bar/PSI bar/PSI
bar/PSI
UNIT UNIT
93.5
98.5
UNIT
93.5
(20.1)
(25.1)
9.1
14.1
(20.1)
10
G1/4 G1/4
12
ø26.8 ø26.8
G1/4A
ø18.8
57
46.3
40.5
73.4
SCSD-S27
19
30
SW27
73
ø32
The Controller Family
87
64 Catalogue 4083/UK
SCPSD PressureController
Order code Connection cable and single plug
SCPSD digital pressure switch Connection cable, assembled SCK-400-xx-xx
2 switching outputs; no analogue output: SCPSD-xxx-04-x7 (open cable end)
M12x1 connecting plug; 4-pole
Cable length (m)
1 switching output; with analogue output: SCPSD-xxx-14-x7 2m 02
M12x1 connecting plug; 4-pole 5m 05
10 m 10
2 switching outputs; with analogue output SCPSD-xxx-14-x5
M12x1 connecting plug; 5-pole Connecting plug
M12 cable jack; straight 45
Pressure range M12 cable jack; 90° angled 55
004 004
010 010 Single connector
016 016 M12 cable jack; straight SCK-145
060 060 M12 cable jack; 90° angled SCK-155
100 100
250 250
400 400
600 600
Version
G1/4 BSPP outer thread 1
G1/4 BSPP inner thread 2
Accessories:
PC Programming KITSCSD-PRG-KIT
Securing clamp SCSD-S27
Reducing adapter M22x1.5SCA-1/4-M22x1.5-ED
Reducing adapter G1/2 BSPPSCA-1/4-ED-1/2-ED
Attenuation adapter SCA-1/4EDX1/4-D
Attenuation adapter SCA-1/2EDX1/2-D
Flange adapter SCAF-1/4-40
for mechanical pressure switch
Order example
SCPSD-100-04-27
Pressure range 100 bar
2 switching outputs
G1/4 BSPP inner thread
M12 connecting plug
SCPSD-004-14-17
The Controller Family
65 Catalogue 4083/UK
SCTSD TemperatureController
Device features
Compact size Pivoting
Rugged Password
Dependable °C, °F
Easily operable
Metal housing
High protection class
Modular construction
Many variants
Analogue output
1234
The TemperatureController combines the functions of a The analogue output is individually adjustable
temperature switch, a temperature sensor and a display
0/4...20 mA switchable
device.
Adjustable start temperature
Temperature display (Thermometer) Adjustable end temperature
Switching outputs
Analogue signal Reliable and safe
Simple operation, extensive functionality and a modular de- A functional error is signalled and can be processed further
sign are the most important characteristics of the Tempera- according to DESINA. Parameters can be password pro-
tureController. tected to avoid unauthorised changes.
The TemperatureController offers excellent technical spec-
ifications, optimum temperature management, combined Rugged
with a variety of installation options. It is perfect for applica- The housing is made of metal and is resistant to mois-
tions when the temperature needs to be reliably monitored ture, shock and vibrations. The electronics are protected
and easily viewed. against reverse polarity, over-voltage and short-circuits.
66 Catalogue 4083/UK
SCTSD TemperatureController
Application example Tank temperature monitoring
Machine On / Off Cooling
The facility should shut down when the tank temperature If the temperature climbs above 50°C (122°F), the tank
falls below 10°C (50°F) or climbs above 60°C (140°F). temperature should be cooled with a refrigerating unit
down to 40°C (104°F).
A protective wire-break mechanism should be considered
to improve safety.
Temperature in °C
Tank temperature
SP1 = 60 °C
(140°F)
SP2 = 50 °C
(122°F)
rSP2 = 40 °C
(104°F)
rSP1 = 10 °C
(50°F)
Cooling Cooling
Switching output 2 If the temperature exceeds 50 °C, the contact S2 closes and only resets at 40 °C.
SP2 = 50 °C/ (122°F) On
rSP2 = 40 °C / (104°F)
Hysteresis /
NO contacts Off
Time
The Controller Family
67 Catalogue 4083/UK
SCTSD Modular TemperatureController
Device features Optical interface
Switch status is shown
Everything at a glance
Sloped display
Digital display
Large
Illuminated Easy to use
Display 3 large buttons
°C, °F Display of the unit
Current temperature
Minimum temperature
Maximum temperature Rugged
Switching points Metal housing
Waterproof
Variable installation
Excellent interference immunity
Compact size
Vibration proof
290° pivotable
Shock proof
Connect as required
2 switching outputs
Analogue output Tube clamp
0...20 or 4...20 mA Safe installation with the sturdy
Freely programmable SCSD-S27 clamp
Scalable
Plug
M12
DIN EN
175301-803 Form A
(old DIN43650)
Programming module
Adjustable through
ControllerWIN Software
The Controller Family
68 Catalogue 4083/UK
SCTSD Modular TemperatureController
Device features
Cable
SCK-410-03-45-45
Adjustable height
Through clamping thread
SCA-TT-10-1/2
Temperature sensor
Stainless steel
Wide range of compatible sub-
High pressure temperature sensor stances
Diverse lengths
630 bar
SCTT-10-xxx-07
SCTT-20-010-07
Connection adapter
SCA-TT-10-SD
Immersion tube
Additional with
High pressures
Aggressive substance
Immersion tube SCA-TT-10-xxx
The Controller Family
69 Catalogue 4083/UK
SCTSD Modular TemperatureController
Technical data
Input parameters SCT-150 Housing
Display range -50...+150 °C / (-58...302°F) Orientation adjustable to 290°
Sensor input PT1000 Material Die-cast zinc Z 410; painted
Sensor connection M12x1; 4-pole Foil material Polyester
Output values Display 4-digit 7-segment LED;
Switching accuracy ± 0.35 % FS red; digit height 9 mm
at 25 °C Protection degree IP67 EN 60529
Display accuracy ± 0.35 % FS ± 1 Digit IP65 with device plug
at 25 °C DIN EN 175301-803 Form A
(old DIN43650)
Electrical connection
Ambient conditions
Supply voltage V+ 15...30 VDC nominal
24 VDC; Protection class 3 Ambient temperature -20...+85 °C / (-4...185°F)
range
Electrical connection M12x1; 4-pole; 5-pole;
Device plug Storage temperature -40...+100 °C / (-40...212°F)
DIN EN 175301-803 Form A range
(old DIN43650) Vibration resistance 20 g; 10...500 Hz
Short-circuit protection Yes IEC60068-2-6*
Shock resistance 50 g; 11 ms
Overload protection Yes
IEC60068-2-29*
Current consumption < 100 mA
Outputs
EM compatibility
Switching outputs 2 x PNP high-side switch,
Disturbance emissions EN 61000-6-3 0.7 A/switch
Resistance to interference EN 61000-6-2 Contact functions NO / NC contact;
* does not apply for version DIN EN 175301-803 Form A (old DIN43650) window / hysteresis
Response speed 300 ms
Accuracy ± 1 % FS
Analogue output 0/4...20 mA; programmable;
freely scalable;
4...20 mA = -40...125 °C /
(-40...257°F)
70 Catalogue 4083/UK
SCTSD Modular TemperatureController
Pin assignment
SCTSD-150-00-06 SCTSD-150-00-07
1 switching output 2 switching outputs
DIN EN 175301-803 Form A 4-pole (old 43650) M12x1; 4-pole
PIN Assignment PIN Assignment
1 V+ 1 V+
2 0 V / GND 2 S2 out
3 S1 out 3 0 V / GND
- 4 S1 out
SCTSD-150-10-07 SCTSD-150-10-05
1 switching output, 1 analogue output 2 switching outputs, 1 analogue output
M12x1; 4-pole M12x1; 5-pole
PIN Assignment PIN Assignment
1 V+ 1 V+
2 Analogue out 2 S2 out
3 0 V / GND 3 0 V / GND
4 S1 out 4 S1 out
5 Analogue out
SCTT-x0-xxx-07
71 Catalogue 4083/UK
SCTSD Modular TemperatureController
M12 connecting plug DIN 43650 High pressure temperature sensor
SCTSD-150-x4-05 SCTSD-xxx-00-06 SCTT-20-010-07
46.3 39.5 47.7 Ø15
M12x1
I II
SensoControl
°C/°F
73.4
UNIT
42.5
93.5 SW17
HEX17
(20.1)
12.1
SW27
8
O-Ring
17.5
7.65x1.78
14
M12x1
Ø7
ø32 M24x1.5
M10x1
30
SW19
41
SW27
28
SW27
Eolastic-
14
Dichtung
Eolastic-
14
Dichtung
G1/2A
ø26.8
G1/2A
ø26.8
Material: GE10LR1/2EDOMD71:
Stainless Steel 1.4404 (with 10 mm bore hole)
Male stud: Stainless Steel 1.4571
G1/2A BSPP DIN3852-E EO-2-functional nut:
L
ED1/2VITX (FKM)
ø10
72 Catalogue 4083/UK
SCTSD Modular TemperatureController
Sensor cable 3 m (accessory) Order code
SCK-410-03-45-45
46 41.5 SCTSD module
1 switch output; no analogue output SCTSD-150-00-06
DIN EN 175301-803 Form A
Ø14.5
Ø14.5
(old DIN 43650) connecting plug
SCSD-S27
1 switch output; with analogue output SCTSD-150-10-07
57
M12x1 connecting plug; 4-pole
Accessories:
Securing clamp SCSD-S27
3
73 Length mm
87 100 mm 100
150 mm 150
250 mm 250
73 Catalogue 4083/UK
SCTSD high pressure TemperatureController
Device features Optical interface
Switch status is shown
I II
Sloped display
Digital display
°C/°F
Large
Illuminated Easy to use
Display 3 large buttons
UNIT
°C, °F Display of the unit
Current temperature
Minimum temperature
Connect as required
Maximum temperature
2 switching outputs
Switching points
Analogue output
Rugged 0...20 or 4...20 mA
Metal housing Freely programmable
Waterproof Scalable
Excellent interference immunity M12 connecting plug
Vibration proof
Shock proof
Variable installation
Compact size High pressure resistance
290° pivotable Up to 630 bar (1166 psi)
Programming module
Adjustable through
ControllerWIN Software
The Controller Family
74 Catalogue 4083/UK
SCTSD high pressure TemperatureController
Technical data
75 Catalogue 4083/UK
SCTSD high pressure TemperatureController
M12 connecting plug Pin assignment
SCTSD-150-x4-05
SCTSD-150-02-07
46.3 39.5
2 switching outputs
I II
M12x1; 4-pole
SensoControl
PIN Assignment
°C/°F
1 V+
73.4
UNIT
2 S2 out
93
3 0 V / GND
4 S1 out
SW27
9
18.5
O-Ring
7.65x1.78
ø32 Ø7
SCTSD-150-12-07
M10x1 1 switching output, 1 analogue output
M12x1; 4-pole
PIN Assignment
1 V+
2 Analogue out
3 0 V / GND
4 S1 out
SCTSD-150-12-05
2 switching outputs, 1 analogue output
M12x1; 5-pole
PIN Assignment
1 V+
2 S2 out
3 0 V / GND
4 S1 out
5 Analogue out
The Controller Family
76 Catalogue 4083/UK
SCTSD high pressure TemperatureController
Order code
SCTSD high pressure
2 switch outputs; no analogue output SCTSD-150-02-07
M12x1 connecting plug; 4-pole
Accessories
PC Programming Kit SCSD-PRG-KIT
Connecting plug
M12 cable jack; straight 45
M12 cable jack; 90° angled 55
Single connector
M12 cable jack; straight SCK-145
M12 cable jack; 90° angled SCK-155
77 Catalogue 4083/UK
SCTSD-L combination switch
Device features
Compact design Fixed level contacts
Temperature display Only one float
Individually adjustable Preset level
temperature switching outputs Warning and shutdown min.
Small switching hysteresis Shut-down min./max.
Preset Up to one meter probe length
For standard oils
For cooling
1234
For switching off (Tmax)
78 Catalogue 4083/UK
SCTSD-L combination switch
Technical data
General Preset temperatures
Measurement principle Magnetic float Switching output 1* 50 °C (122°F) contact closed
reed switches (cooling on)
Float NBR, Ø 18 mm, 45 °C (113°F) contact open
length 25 mm, magnetic (cooling off)
Viscosity Max. 250 cSt at 25 °C Switching output 2* 63 °C (145°F) contact open
Density at least 0.750 g/cm³ (shutdown)
Probe length Lmax Lowest switching point Switching current: 0.5 A max.
+ 35 mm Switching voltage 100 V max.
Operating pressure 1 bar max. Switching power 10 W max.
Accuracy ±2 mm Switching function NO or NC (bi-stable)
Material Contact material Rhodium
Protection tube Brass Plug M12x1; 4 pin
Connector thread Brass Smallest difference between 30 mm
Ambient conditions L1 and L2
Temperature of substance -20...+85 °C / (-4...185°F) Smallest switching position 30 mm from the tank lid
L1
Storage temperature -40...+100 °C / (-40...212°F)
*) Each temperature switching output can be individually re-programmed or
adjusted:
NO/NC contact
On/off switching temperature
Hysteresis / window function
Time delay and attenuation
79 Catalogue 4083/UK
SCTSD-L combination switch
Temperature pin assignment
SCTSD-150-0X-0X
(Refer chapter SCTSD)
SCTSD-L-xxxxO-xxFO
SCTSD-L-xxxxx-xxxxx-KIT5
2 switching outputs
M12x1; 4-pole
PIN Assignment
1 V+
2 S2 out
3 0 V / GND
4 S1 out
SCTSD-L-xxxxx-xxxxx-17-KIT5
1 switching output, 1 analogue output
M12x1; 4-pole
PIN Assignment
1 V+
2 Analogue out
3 0 V / GND
4 S1 out
SCTSD-L-xxxxO-xxFO
SCTSD-L-xxxxx-xxxxx-15-KIT5
2 switching outputs, 1 analogue output
M12x1; 5-pole
PIN Assignment
1 V+
2 S2 out
3 0 V / GND
4 S1 out
The Controller Family
5 Analogue out
80 Catalogue 4083/UK
SCTSD-L combination switch
Order code
Combination switch CTSD-L-xxxxx-xxxxxQ2
S
Combination switch Marine SCTSD-L-xxxxx-xxxxx-MAQ2
(approved by DNV/GL/ABS)
2 level outputs, temperature display
2 temperature switching outputs
Version
Falling closing FC
Falling open FO
Rsing closing RC
Rising open RO
Version
Falling closing FC
Falling open FO
Rising closing RC
Rising open RO
Plug-in connection
M12; 4-pole (1 temperature switching output) 7
M12; 5-pole (2 temperature switching outputs) 5
81 Catalogue 4083/UK
SCLSD LevelController
Device features
Proven measuring system
Level display
mm / inch / % display
High and low display
Analogue output
Switching outputs
No surge pipe necessary
Replacement for several
mechanical switches
1234
Pivoting
0/4...20 mA switchable Thanks to these easy switching functions (hysteresis and win-
Upper level adjustable dow functions, NC or NO functions), intelligent adjustments
Lower level adjustable can be set which are normally not possible using a mechan-
ical level switch. Therefore, many switches can be replaced
with one controller. With the optional analogue output, the lev-
el and temperature can be monitored easily with a controller
(e.g. for leakage monitoring).
82 Catalogue 4083/UK
SCLSD LevelController
Application example: Tank temperature monitoring
Since the conventional specifications for mechanical level I II Display
switches (the mm data from the tank lid) are often used
SensoControl
in mm
mm/inch
without
during project planning, these data are selected here for a
%
UNIT offset
practical example. SCLSD-
370 Resulting switch value
for a SCLSD-370 mm
Facility off
High Stop above:
If the tank level falls below 310 mm (measured from the 370 mm - 70 mm = 300 mm
330 Stop below:
tank top / dry run) or climbs above 70 mm (measured from 370 mm - 310 mm = 60 mm
MAX
the tank top / overflow), switch off should occur. A pro- Window function, NO contact
Measurement display
tective wire-break mechanism should be considered to im- The output S1 is closed,
prove safety. if the level is between
300 and 60 mm.
Tank level
SP1 = 300 mm
SP2 = 260 mm
rSP2 = 130 mm
rSP1 = 60 mm
Fill tank Fill tank If the level falls below 130 mm, the contact closes and opens again when 260 mm is exceeded.
Switching output 2 On
SP2 = 260 mm
rSP2 = 130 mm
Hysteresis NC
contact Off
Time
83 Catalogue 4083/UK
SCLSD LevelController
Device features Optical interface
I II
Switch status is shown
SensoControl
Everything at a glance
Sloped display mm/inch
Digital display
% Easy to use
Large 3 large buttons
UNIT
Illuminated Display of the unit
Display
Connect as required
mm, inch, or %
2 switching outputs
Actual level
Analogue output
High and low display
0...20 or 4...20 mA
Switching points
Freely programmable
Rugged Scalable
Metal housing M12 connecting plugs
Waterproof
Excellent interference immunity
Vibration proof
Shock proof
Variable installation
No surge pipe necessary
Compact size
Electronic attenuation
290° pivotable
adjustable attenuation
G3/4 BSPP
Flange for DIN
Programming module
Adjustable with
Proven measuring system
ControllerWIN Software
High float dynamics
Small design
Universal usage
The Controller Family
84 Catalogue 4083/UK
SCLSD LevelController
Technical data
Input parameters Housing
Measuring component Resistance reed chain with float Adjustable direction to 290°C
Connector thread G3/4 BSPP; nickel-plated brass; Material Die-cast zinc Z 410; painted
ED soft seal NBR*
Foil material Polyester
Parts in contact with Brass; nickel-plated brass; NBR*
Display 4-digit 7-segment LED;
substances
red; digit height 9 mm
Temperature range of -20...+85 °C / (-4...185°F)
Protection degree IP67 DIN EN 60529
substance
Output values Ambient conditions
85 Catalogue 4083/UK
SCLSD LevelController
Display possibilities
Example of a percent display Example of a mm display
I II
=
I II Display Display
in mm in mm
SensoControl SensoControl
=
UNIT = with Offset with Offset 200 mm
mm/inch
% mm/inch
%
UNIT
UNIT
SCLSD-
SCLSD-XXX
Measurement display
Activer
170 mm
290 mm
440 mm
range
Min
Offset
= 200 mm
Pin assignment
SCLSD-xxx-00-07 SCLSD-xxx-10-07
The Controller Family
2 switching outputs; M12x1; 4-pole 1 switching output, 1 analogue output, M12x1; 4-pole
PIN Assignment PIN Assignment
1 V+ 1 V+
2 S2 out 2 Analogue out
3 0 V / GND 3 0 V / GND
4 S1 out 4 S1 out
86 Catalogue 4083/UK
SCLSD LevelController
39.5 Order code
I II I II
SensoControl SensoControl
SCLSD LevelController
mm/inch
%
mm/inch
% 2 switching outputs; SCLSD-xxx-00-07
UNIT UNIT
2 switching outputs Marine; SCLSD-xxx-00-07-MA
91.5
(approved by DNV/GL/ABS)
SW32
no analogue output
hex.32
M12x1 connecting plug; 4-pole
13.5
ED-
Sealing
<40
L1
L1
PIN Assignment
1 V+ Single connector
2 S2 out M12 cable jack; straight SCK-145
3 0 V / GND M12 cable jack; 90° angled SCK-155
4 S1 out
5 Analogue out
87 Catalogue 4083/UK
SCLTSD LevelTempController
Device features
Proven measuring system
Pivoting
Level display
mm / inch / % display
High and low display
Analogue output
Switching outputs
Only one hole
No surge pipe necessary
1234 1234
Replacement for several
mechanical switches
88 Catalogue 4083/UK
SCLTSD LevelTempController
Application examples
SCLSD
SP2 = 260 mm
rSP2 = 130 mm
rSP1 = 60 mm
Facility On/Off Facility The output S1 is closed if the level is between 300 and 60 mm.
Switching output 1 On
SP1 = 300 mm
rSP1 = 60 mm
Window function/ Off
Application example NO contact
SCTSD
Temperature
in °C
Tank temperature
SP1 = 60 °C
SP2 = 50 °C
rSP2 = 40 °C
rSP1 = 10 °C
Facility On/Off Facility The output S1 is closed if the temperature is between 60 °C and 10 °C.
Switching output 1 On
SP1 = 60 °C/ (140°F)
The Controller Family
rSP2 = 10 °C / (50°F)
Window function, NO Off
contact
Cooling Cooling
Application example Switching output 2 On
If the temperature exceeds 50 °C, the contact S2 closes and only resets at 40°C.
89 Catalogue 4083/UK
SCLTSD LevelTempController
Device features Optical interface
I II I II
Switch status is shown
SensoControl SensoControl
Everything at a glance
Sloped display mm/inch
%
°C/°F
Easy to use
Digital display
3 large buttons
Large UNIT UNIT
Display of the unit
Illuminated
Switching points Connect as required
Display level 2 switching outputs
mm, inch, or % Analogue output
Actual level 0...20 or 4...20 mA
High and low display Freely programmable
Temperature display Scalable
°C, °F M12 connecting plugs
Current temperature
Rugged Twin concept
Metal housing 2 in 1
Waterproof
Excellent interference immunity
Vibration proof
Shock proof No surge pipe necessary
Electronic attenuation
adjustable attenuation
Variable installation
A coupling hole
Compact size
290° pivotable
G3/4 BSPP
Level
DIN flange
Proven measuring system
Programming module
High float dynamics
Adjustable with Small design
ControllerWIN Software Universal usage
The Controller Family
Temperature sensor
Integrated in the rod end
90 Catalogue 4083/UK
SCLTSD LevelTempController
Technical data
Electrical connection Level
Supply voltage V+ 15...30 VDC nominal Input parameters
24 VDC; Protection class 3 Measuring component Resistance reed chain with float
Electrical connection M12x1; 4-pole; 5-pole;
Connector thread G3/4 BSPP; nickel-plated brass;
with gold-plated contacts
ED soft seal NBR*
Short-circuit protection Yes
Parts in contact with
Brass; nickel-plated brass; NBR*
Protection against wrong Yes substances
insertion Temperature range of
≤ 80 °C / (≤ 176°F)
Overload protection Yes substance
Current consumption < 100 mA Output values
Housing Switching point accuracy ± 1 % FS at 25 °C / (77°F)
Adjustable direction to 290°C Display accuracy ± 1 % FS ± 1 Digit at 25 °C / (77°F)
Material Die-cast zinc Z 410; painted Response speed ≤ 700 ms
Foil material Polyester Resolution 7.5 mm
Display 4-digit 7-segment LED; Float
red; digit height 9 mm Material NBR
Protection degree IP67 DIN EN 60529
Dimensions Ø 18 mm, Length 35 mm
Ambient conditions
Viscosity Max. 250 cSt at 25 °C / (77°F)
Ambient temperature
-20...+85 °C / (-4...185°F) Density at least 0.750 g/cm³
range
Temperature range of Level rod
≤ 80 °C / (≤ 176°F)
substance Material Stainless steel
Storage temperature Dimensions Ø 8 mm
-40...+100 °C / (-40...212°F)
range
Operating pressure 1 bar
EM compatibility
Temperature
Disturbance emissions EN 61000-6-3
Output values
Resistance to interference EN 61000-6-2
Switching point accuracy ± 0.35 % FS at 25 °C / (77°F)
Outputs
Display accuracy ± 0.35 % FS ± 1 Digit at 25 °C
Switching outputs Two MOSFET high-side switches / (77°F)
(PNP)
Response speed ≤ 300 ms
Contact functions NO / NC contact;
window / hysteresis Analogue output 0/4...20 mA; programmable;
function freely adjustable freely scalable;
4...20 mA = -40...125 °C /
Switching voltage V+ -1.5 VDC (-40...257°F)
Switching current max. 0.5 A per switch
* different sealing material (FKM, EPDM etc.) upon request
Short-circuit current 2.4 A per switch
Analogue output 0/4 to 20 mA; programmable;
freely scalable
The Controller Family
91 Catalogue 4083/UK
SCLTSD LevelTempController
Display possibilities
Example of a percent display Example of a mm display
I II I II
I II I II
SensoControl SensoControl
SensoControl SensoControl
mm/inch
%
°C/°F
= mm/inch
%
°C/°F Display Display
= in mm in mm
UNIT =
UNIT UNIT
SCLTSD-
250 370 520 SCLTSD- SCLTSD-
Length of 250 mm 370 mm 520 mm 250 370 520 250 370 520
sensor
High
SET1
Measurement display
Active
170 mm
290 mm
440 mm
range
Min
Offset
= 200 mm
Pin assignment
SCLTSD-xxx-00-07 for temperature and level SCLTSD-xxx-10-07 for temperature and level
The Controller Family
2 switching outputs; M12x1; 4-pole 1 switching output, 1 analogue output, M12x1; 4-pole
PIN Assignment PIN Assignment
1 V+ 1 V+
2 S2 out 2 Analogue out
3 0 V / GND 3 0 V / GND
4 S1 out 4 S1 out
92 Catalogue 4083/UK
SCLTSD LevelTempController
79.2 Order code
SCLTSD LevelTempController
I II I II
SensoControl SensoControl
2 switching outputs; SCLTSD-xxx-00-07
2 switching outputs Marine; SCLTSD-xxx-00-07-MA
(approved by DNV/GL/ABS)
mm/inch °C/°F
%
109.5
1 switching output; SCLTSD-xxx-10-07
1 switching output Marine; SCLTSD-xxx-10-07-MA
(approved by DNV/GL/ABS)
with analogue output
M12x1 connecting plug; 4-pole
13.5
800 mm 800
1000 mm 1000
Accessories
PC Programming Kit SCSD-PRG-KIT
Flange adapter SCAF-3/4-90
ø8 6-hole connection DIN 24557, part 2
Connecting plug
M12 cable jack; straight 45
SCLTSD-xxx-10-05 for temperature and level M12 cable jack; 90° angled 55
The Controller Family
93 Catalogue 4083/UK
SCOTC OilTankController
Device features
Proven measuring system
Level and temperature display
mm / inch / % display
High and low display
Only one hole
Continuous level measurement
Connection
Filling coupling
Air filter 1234 1234
Low pressure
No surge pipe necessary
In addition to the LevelTempController, the OilTankCon- As the switching point no longer needs to be specified at
troller also offers standardised connections for an air filter the time of order, the versions of mechanical level switches
and a fill coupling. required is reduced.
When monitoring the tank for series use, this integration
Temperature
of level and temperature functionality together with air filter
and fill adapter port opens up many possibilities. An ad- The temperature in the substance is continuously recorded
ditional connecting hole is required for the four functions. and displayed. The switching outputs can be individually
set up just like the LevelController. Naturally all the conveni-
The OilTankController combines the functions of a ent switching functions are available: window, hysteresis
level and temperature switch, a level and temperature function and open/close as well as an analogue output for
sensor and a level and temperature display: temperature.
Level and temperature display
(thermometer / inspection glass) Reliable and safe
Switching outputs Parameters can be password protected to avoid unau-
Analogue signal thorised changes.
Level
Universal
The position of the float is finely (≥ 5 mm) and continuously
In combination with the comfortable switch functions
recorded and shown in the display in mm or inch. Because
like hysteresis and window function, open/close contact
the level is continuously recorded, the danger of individual
functions LevelTempController intelligent settings can
mechanical contacts "sticking" no longer exists. Therefore
be made which are not possible with a mechanical level/
the operational reliability of the monitored plant is greatly
The Controller Family
94 Catalogue 4083/UK
SCOTC OilTankController
Application examples
SCLSD
SP2 = 260 mm
rSP2 = 130 mm
rSP1 = 60 mm
Facility On/Off Facility The output S1 is closed if the level is between 300 and 60 mm.
Switching output 1 On
SP1 = 300 mm
rSP1 = 60 mm
Window function/
Off
NO contact
Fill tank Fill tank If the level falls below 130 mm, the contact closes and opens again when 260 mm is exceeded.
Switching output 2 On
SP2 = 260 mm
rSP2 = 130 mm
Application example Hysteresis NC contact Off
Time
Refer to page 83
SCTSD
Temperature
in °C
Tank temperature
SP1 = 60°C
SP2 = 50°C
rSP2 = 40°C
rSP1 = 10°C
Facility On / Off Facility The output S1 is closed if the temperature is between 60 °C and 10 °C.
Switching output 1
The Controller Family
On
SP1 = 60 °C/ (140°F)
rSP2 = 10 °C / (50°F)
Window function, NO Off
contact
Cooling Cooling If the temperature exceeds 50 °C, the contact S2 closes and only resets at 40°C.
Switching output 2 On
SP2 = 50 °C/ (122°F)
rSP2 = 40 °C / (104°F)
Hysteresis/NO contact Off
Application example Time
Refer to page 67
95 Catalogue 4083/UK
SCOTC OilTankController
Device features 6-hole standard for
Ventilation filter*
(DIN 24557, part 2)
Getting to the point
Compact construction (4 in 1)
Easy adjustment of the
switching points using the menu G3/4 BSPP for
Analogue output Filling coupling*
Safety control
Cost savings in the logistics,
assembly and maintenance
ControllerWIN Software
96 Catalogue 4083/UK
SCOTC OilTankController
Technical data
SCOTC 250 370 520 800 1000
Tank installation length 250 mm 370 mm 520 mm 800 mm 1000 mm
Adjustment range 40...210 mm 40...330 mm 40...480 mm 40...760 mm 40...960 mm
4...20 mA = -40...125 °C /
Switching current max. 0.5 A per switch (-40...257°F)
Short-circuit current 2.4 A per switch Optional temperature switch (S3 out)
Optional analogue output Alarm contact with Open contact
Measuring range 0/4...20 mA; programmable > 65 °C
Error ± 1 % FS
Load ≤ 500 Ω from Vb > 18 VDC
97 Catalogue 4083/UK
SCOTC OilTankController
Pin assignment
Without safety-control-output With safety-control-output
SCOTC-xxxx-00-07 SCOTC-xxxx-00-05
for temperature and level Level:
2 switching outputs Two variable switching outputs,
M12x1; 4-pole One fixed safety-control-output level min/max;
PIN Assignment
M12x1; 5-pole
1 V+ PIN Assignment
2 S2 out 1 V+
3 0 V / GND 2 S2 out
4 S1 out 3 0 V / GND
4 S1 out
5 S3 out
(L-Low / L-High)
SCOTC-xxxx-10-07
for temperature and level SCOTC-xxxx-00-05
1 switching outputs, 1 analogue output Temperature:
M12x1; 5-pole Two variable switching outputs,
One fixed safety-control-output temperature max. 65 °C
PIN Assignment
M12x1; 5-pole
1 V+
2 Analogue out PIN Assignment
3 0 V / GND 1 V+
4 S1 out 2 S2 out
3 0 V / GND
4 S1 out
5 S3 out
(T-High)
SCOTC-xxxx-10-05
for temperature and level
2 switching outputs, 1 analogue output
M12x1; 5-pole
PIN Assignment
1 V+
2 S2 out
3 0 V / GND
4 S1 out
5 Analogue out
The Controller Family
98 Catalogue 4083/UK
SCOTC OilTankController
110 90 Order code
SensoControl SCOTC OilTankController *
2 switching outputs; no analogue output SCOTC-xxxx-00-07
M12x1 connecting plug; 4-pole
G3/4
G1/8
95
2 switching outputs; with analogue output SCOTC-xxxx-10-07
M12x1 connecting plug; 4-pole
40
M5
L1
3 switching outputs; no analogue output SCOTC-xxxx-00-05
M12x1 connecting plug; 5-pole
with safety control
1000 mm 1000
Accessories
PC Programming Kit SCSD-PRG-KIT
L1 = length of the sensor (mm)
L2 = active range (mm)
Connection cable and single plug
Connection cable, assembled SCK-400-xx-xx
(open cable end)
Connecting plug
M12 cable jack; straight 45
M12 cable jack; 90° angled 55
Single connector
M12 cable jack; straight SCK-145
M12 cable jack; 90° angled SCK-155
The Controller Family
* Venting filter, filling coupling, low pressure switch and clogging indicator are not
included in the delivery.
99 Catalogue 4083/UK
SCK cable
Device features
One cable for all
Compact size
Accessories
Interference-free
Compatible to:
Sensors
Controllers
M12 plug
DIN EN 175301 (Device plug)
Available in a variety of lengths
The SensoControl® cable was designed for use with the Pin assignment
industrial sensors and switches.
SCK-400-xx-x5
Thus the M12 cable and M12 plug are
PIN
Compact 4 3 1 bn brown braun
Shielded
2 wh white weiß
Five-pole 5
3 bu blue blau
5-pole version 1 2 4 bk black schwarz
5 gy grey grau
The 5-pole cable is suitable for both 4-pole and 5-pole
connections. The sensor variants with a 4-pole connector
are fully compatible with the 5-pole cable. SCK-400-xx-56
Shielding
Shielding protects against interference and ensures im-
proved operational safety.
Higher EMC protection
Accessories
Ø14.5
29.5
SCK-400-xx-55
38.5
27.5
26.5
Ø14.5
SCK-400-xx-56
~45
29.5
27.5
5m 05
10 m 10
Single connector
M12 cable jack; straight SCK-145
M12 cable jack; 90° angled SCK-155
Cable socket DIN EN 175301-803 Form A SCK-006
Ø20 (old DIN 43650)
ØD4
T1
T2
X1)
X1) EOLASTIC-seal
T1
T2
X2) X1)
X1) EOLASTIC-seal
L3 L2
Accessories
T1
T2
L3
L1
SCAF-1/4-40 SCAF-1/4-40
for mechanical pressure switch
T1
T2
°
60
6x
SCAF-3/4-90 SCAF-3/4-90
6-hole connection DIN 24557, part 2
System requirements
Operating system PC / laptop connection Controller connection
Accessories
WIN 98/2000/ME/NT/XP RS232 Parker infra-red interface
(USB using conventional adapter) SCxSD/SCOTC
Accessories for:
I II I II I II I II I II
SensoControl
I II I II SensoControl I II SensoControl I II I II
SensoControl SensoControl
SensoControl
SensoControl SensoControl SensoControl SensoControl SensoControl
SensoControl
Pressure display and Temperature display and Level indication and Level and temperature display and
40
40
Order code
L2
L1
L2
L1
measured. PO
Appendix
30 86 100 38 Temperature conversion
25 77 90 32
Initial value: 100
20 68 80 27
15 59 70 21 °C in °F: 212 °F
10 50 60 16 °F in °C: 37.78 °C
5 41 50 10
0 32 40 4
-5 23 30 -1 Pressure conversion
-10 14 20 -7 Initial value: 35
-15 5 10 -12
bar in psi: 507.675 psi
-20 -4 0 -18
-25 -13 -10 -23
psi in bar: 2.41296 bar
-30 -22 -20 -29
-35 -31 -30 -34
-40 -40 -40 -40
-45 -49 -50 -46
-50 -58 -60 -51
Appendix