A piping system that connect to compressor system. During • Perform Finite Element Analysis (linear and non compressor start-up, a water/air hammering effect occurred in linear) to determine the Fitness for Services (level 3) flare piping system that causing an unpredicted pipe movement condition of damaged pipe and subsequently denting the pipe at three locations. There are • MAWP calculation based on the damaged pipe totally five dent has been found in the three locations. • Compile all analysis result in comprehensive report
The objective of the analysis is assure the mechanical integrity
and safe continuous operation of this piping system and review of piping damage due to mechanical dents