Contents

Supported JT and CATIA V5 versions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-1

What's New . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-1

Problem reports resolved in this release . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-1

Known issues and workarounds . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-1

Global Technical Access Center (GTAC) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-1

Release Notes 3
Chapter 1: Supported JT and CATIA V5 versions

JT files and CATIA V5 files support different versions for reading and writing data. Use the following
table to verify the supported read | write versions for this release.

JT CATPart/CATProduct CGR
Read V6.4 to V10.2 R8 to V5-6R2018 R8 to V5-6R2018
Write V6.4 to V10.2 R14 or R19 R14

Release Notes 1-1


Chapter 2: What's New

• Support for reading files created using CATIA V5-6R2018 release.

• Support for reading CATIA V5 Point Cloud data including Points, Mesh, Scans and Grids. See
documentation for Translate_PointCloudData configuration option in the User guide.

• Support for Solaris Platform is deprecated with this release.

Release Notes 2-1


Chapter 3: Problem reports resolved in this release

PR # Description
8326430 V5 bi-directional trans does not translate Note Object Attribute (NOA)
8359670 Translation of CATIA V5 R26 data fails in case structure option MIMIC is used
8850149 Translated PMI from CATIA V5 is unreadable in JT
8947901 jt_catiav5.exe v11.issues w/ converting CATIA V5 to JT (geometry/PMI)
8978438 unable to Export CATIAV5 Assembly (signal 11 error)
9004842 PMI information is missing in JT file after conversion from CatiaV5
9020983 JT-CATIA V5 v12 cannot convert some CATIA V5 files
9028991 Cannot convert data from CGR to JT
7334540 CATIA to JT Translation ERROR: PXT_PART_prepare_xt returned: 11028,
Geometry representation different - CATIA V5 and translated JT file -
7852156 CATDUAV5

Release Notes 3-1


Chapter 4: Known issues and workarounds

• The translator can read CGR files ranging from R10 to R22. However, the normals for R10 to
R13 CGR files cannot be processed and the resultant JT parts may not shade properly.

• We recommend that you run the translator from a writable directory and that the output directory
specified is also a writable directory.

• The translator updates all parts and ignores the values set for updateChangePartsOnly.

• Spaces between the pound sign (#) and commented text are not supported in the configuration
file. The software supports the following commented text example.#Translate_Bodies=true.

• If the input JT file, translated to CATIA V5, has XT instead of JTBrep, you will realize significant
improvements in quality and performance of the translation.

• For CATIA V5 to JT translations, a few instances have been reported that not all faces are
trimming correctly. If this happens, please notify GTAC and use JTBrep as a work around.

• In order to translate mass properties accurately to JT, compute the mass properties in CATIA
V5 prior to saving the part.
To determine if mass properties were computed correctly, in your CATIA V5 application select
Properties→Mass. If you see the following message:The Part is modified by the Calculation of
Mass Properties, the mass properties were not computed. Select Okay to compute the mass
properties and then translate the part again.

Note
Also, if the material assignment in CATIA V5 changes, consider computing mass
properties by either selecting Properties→Mass in CATIA V5, or by another
acceptable method prior to saving the CATIA V5 part.

• Assembly level representations are not translated. For example, a CGR representation added to
the assembly through the Manage Representations interface is not translated. However, if this
CGR were added to the assembly as a Component through the Insert Existing Component,
the CGR would be translated correctly.

• Internationalized file names are not allowed in CATIA V5. Hence JT files with internationalized
filenames cannot be converted to CATIA V5 User is expected to rename the JT files and any
references to these JT files to ASCII appropriately before issuing a JT to CATIA V5 translation.

• Analytic definitions of tessellated edges are not translated from JT to CGR.

• Enhancements to support geometry visibility in Captures requires Teamcenter Visualization 10.1


or later. For users running earlier versions of Teamcenter Visualization, for example, 9.1.2, this

Release Notes 4-1


Chapter
Chapter 4: 4: Known
Known issues
issues and workarounds
and workarounds

enhancement can be disabled by setting the environment variable CAPTURE_GEOMETRY_VISIBILITY


= false prior to the translation.

• A number of legacy JT readers including NX 9.0, require length units in a v9.5 JT file to be set as
Millimeters instead of ISO compliant millimeters. To produce JT files that have Millimeters as
the unit , set the environment variable USE_ISO_UNIT_NAMING =0 prior to running the translation.

• There is a known limitation in TC Visualization in that it will not display properties/attributes whose
key is longer than 60 characters. Set the environment variable TRIM_PROP_KEY=1 to truncate these
long keys such that the property will display in TC Visualization.

4-2 Release Notes


Chapter 5: Global Technical Access Center (GTAC)

To report any serious problems about this translator or for help obtaining a license, please contact
the Global Technical Access Center.

Phone:

• USA and Canada: (800) 955-0000 or (714) 952-5444

• Outside the United States and Canada: Contact your local support office.

Website:

You can also log and view existing resolutions for incident reports on the Web at
http://www.siemens.com/plm/support

Release Notes 5-1


Siemens Industry Software

Headquarters
Europe
Granite Park One
Stephenson House
5800 Granite Parkway
Sir William Siemens Square
Suite 600
Frimley, Camberley
Plano, TX 75024
Surrey, GU16 8QD
USA
+44 (0) 1276 413200
+1 972 987 3000

Asia-Pacific
Americas
Suites 4301-4302, 43/F
Granite Park One
AIA Kowloon Tower, Landmark East
5800 Granite Parkway
100 How Ming Street
Suite 600
Kwun Tong, Kowloon
Plano, TX 75024
Hong Kong
USA
+852 2230 3308
+1 314 264 8499

About Siemens PLM Software

© 2018 Siemens Product Lifecycle Management


Siemens PLM Software, a business unit of the Siemens
Software Inc. Siemens and the Siemens logo are
Industry Automation Division, is a leading global provider
registered trademarks of Siemens AG. D-Cubed,
of product lifecycle management (PLM) software and
Femap, Geolus, GO PLM, I-deas, Insight, JT, NX,
services with 7 million licensed seats and 71,000 customers
Parasolid, Solid Edge, Teamcenter, Tecnomatix and
worldwide. Headquartered in Plano, Texas, Siemens
Velocity Series are trademarks or registered trademarks
PLM Software works collaboratively with companies
of Siemens Product Lifecycle Management Software
to deliver open solutions that help them turn more
Inc. or its subsidiaries in the United States and in other
ideas into successful products. For more information
countries. All other trademarks, registered trademarks
on Siemens PLM Software products and services, visit
or service marks belong to their respective holders.
www.siemens.com/plm.

You might also like