meee! HITACHI INVERTER- DRIVEN a MULTI-SPLIT SYSTEM HEAT PUMP AIR CONDITIONERS - HI-MULTI SET-FREE FS2 SERIES - AND - HI-MULTI SET-FREE FX SERIES - Cooling Capacity Range Technical Catalog | 2,000 kcal/h to 25,000 kcal/h + Design Information 2,300 W to 29,050 W 7,900 Btu/h to 99,200 Btuih hist it outdoor Unit Heating Capacity Range Indoor Units foor Units 2,250 kealih to 28,000 kcal/h +In-the-Celllng Type FS2 Series 2600 W to 32.580 W RPI-0.BFS. RAS-5FS2 8.900 Blwh to 111,100 Btuh RPI-IES RAS -OFS2 RPI-1,5FS. RAS-10FS2 RPI-2FS. API-2.5FS. FX Series RPI-SFS RAS-8FX +4-Way Cassette Type RAS- 10FX RCI-1FSE RCI-aFSE RCI-SFSE + 2-Way Cassette Type RCD-1FS RCD-1.5FS RCD-2FS RCD-2.5FS + Wall Type RPK.1.5FS * Floor Type - RPF-1.5FS f - | ‘+ Floor Concealed Type RPFI-1.5FS. «Gelling Type RPC-2.5FS(E) This inverter-driven multi-split system heat pump SHP to 10HP consists of one outdoor unit, air conditioners, HI-MULTI SET-FREE FS2 and various indoor units and remote control switches — FX Series, have been developed to provide {for each indoor unit. individual control, comfortable operation control, By utilizing an optional Central Station, 258 ‘great power saving operation through the year _indoor unils can be controlled. {and full automatic operation for smallmedium This system can provide the best which can not buildings. be obtained by the current one-to-one systems. ‘The HI- MULTI SET-FREF Series ranainn trom eps. Int 1996 - CONTENTS - No. Page FEATURES .......... 1.1 System Foatures ........ 1.2 Features on Indoor Units and Outdoo: Units. 1.8 Features on Optional Liquid Crystal Remote Control Switch, 7-1 “Day 0 Timer ‘and Central Station ...... 27 1.3.1 Liquid Crystal Remote Control Switch, PC-2H. (ptonad 27 1.3.2 7-Day Timer PSC-3T (Optional) .. 29 1.8.8 Central Station, PSC-3S1 (Optional) 30 2. GENERAL DATA sesees 31 2.1 General Data for indoor Units 31 2.2 Genoral Data for Outdoor Units .... 38 3. DIMENSIONAL DATA 40 3.1. Dimensional Data for Indoor Units 40 3.2 Dimensional Data for Outdoor Units ... 54 4, SELECTION DATA... seeteetesetetstetetetetesesees 62 4.1. Operation Space : ez 42 Center of Gravity cee 65 43. Selection Guide . 66 44 Capacity Characteiste Curve of Outdoor Units - n 45 Cooling Capacity Table of 100% Combination (Dimension: % 1,000 kealfh) : 75 4.6 Heating Capacity Table of 100% Combination (Dimension: X 1,000 keal/n) 76 4.7 Cooling Capacity Table of 100% Combination (Dimension: kW) 7 4.8 Heating Capacity Table of 100% Combination (Dimension: kW) 78 4.9 Correction Factor According to Piping Length ... . 79 4.10 Sensible Heat Factor fees 81 4.11. Correction Factor According to Detrosting Operation .. : Bt 4.12 Attention for SET-FREE FX Series... 82 4.19 Fan Performance . : 84 5. ELECTRICAL DATA 86 6. SOUND DATA... 88 7. WORKING RANGE, 95 8. OPTIONAL ACCESSORIES ..... ve sees 96 8.1 quid Crystal Remote Control Switch (PC-2H) » 96 82. 7-Day Timer (PSC-3T) wees 96 8.3 Central Station (PSC-3S1) 96 8.4 Remote Contol Cable (PRC-10E~PRC-30E) . 98 85. 3P Connector Cable (PCC: 1) . 98 8.6 Remote Sensor (THM-R2)......ccssescseseseerseseseeseees 99 87 Drain kit (DBS-26) 29 88 Muti-Kit - vite 100 8.9 Fresh Air Intake for 4-Way Cassette Type Indoor Units... sc... 104 8.10 Branch Discharge Duct for 4-Way Cassette Type Indoor Units... : 108 8.11. 3-Direction Air Flow for 4-Way Cassette Type indoor Units 110 8.12 Drein-Up Mechanism (DU-23, for RPI-2FS, RPI-2.5FS, RPI-4FS end RPI-5FS) m 18.13 Air Filter and Filtor Box for In-the-Ceiling Type Indoor Units 9. COMPONENT DATA ..... 113 HITACHI + CONTENTS - No. 10. CONTROL SYSTEM 10.1 Refrigeration Cycle 10.2 Control System 10.3 System Control ..... 10.3.1 Control in a Room 10.32 Group Contra from a Remote Place ...... 10.3.3. Control in a Room/Contial trom a Remote Place 10.4 Standard Operation Sequence 10.5 Protection and Satety Control... 10.8 Safety and Control Device Setting 10.7 Standard Electrical Wiring Diagram 11. FOUNDATION PROVISION 12, REFRIGERANT PIPING PROVISION 13, FIELD WIRING PROVISION 14, MISCELLANEOUS NOTES 15, STANDARD SPECIFICATIONS 16. CAUTION ON REFRIGERANT LEAKAGE 46.1 Maximum Permissible Concentration of HCFC Gas .... 16.2 Calculation of Refrigerant Concentration 16.3 Countermeasure for Rerigerant Leakage According to KHK Standard HITACHI Page 16 ne 123 126 124 125 128 126 142 142 145 161 163 168 wm 17 173 173 173 173 1. FEATURES 1.1 System Features HI-MULTI SET-FREE FOR SMALL/MEDIUM OFFICE BUILDINGS HITACHI proudly introduces the highly-etficient and reliable air conditioning system, "HI-MULT! ‘SET-FREE" for small and medium office buildings. Recently, increased numbers of buildings are requiring “Inteligent facilites - communication networks, office automation, including a comfortable environment. Particularly, comfortable space is required al the day through the yes bulddings. This muti-spiit system "HI-MULTI SET-FREE" can meet arin office air conditioner, these requirements. The proven combination of the scroll compressor and the inverter provides the best air Various Indoor Units and Combinations [FS2 & FX) 21 indoor units in 7 types are lined up for this ‘SET-FREE to meet various building requirements, (@.8HP through SHP) Conditioning for smallimedium office buildings. Nominal Capacity (AP) Indoor Unit Type 08 10 Ta-the-Caling 1S 20 25 40 50 “&-Way Cassette ° o ojo 2-Way Cassette oO o Walt Floor Floor Concealed alolajo Ceiling O: Available NOTE: By dpp switch seting, the nominal capacity can be adjusted within approximately 0.25HP. However 0.8HP and 1HP is“ HP. (For details, refer to item 10.6.) Able to Connect One Outdoor Unit with up to 12 Indoor Units [FS2] ‘of the indoor units when compared with the nominal Utilizing an inverter control, a wide range of ‘operation capacity control is also available. ‘A maximum total capacity of 130% and a minimum total capacity of 50% can be chosen by combination ‘outdoor unit capacity. Therefore, most office buildings, the new system ‘can meet individual air conditioning requirements in Tae Tes |_Masam Rina Mirena Couidoor Unt Mode! | combination | Combination |Comtanaton | Maxine | agi Capacty” | Capaaty”|crindoor” | Cambaaton | Coeraton ey | ee | Un Capacty (4) RRAS-5FS2, RAS-SFX 25 65 2 8 08 ras-erse,ras-erx | 40 | 100 2 |rsxiece | Fsz08.Fe10 fas-s0rse.ras-iox | so | 190 2 | Fsaia.rxe | Fsz08. Fx: 10 FS2 System HITACHI [FEATURES® Reduced Total Outdoor Unit Capacity [FS2 & FX) The Set-Free system enable the outdoor unit o be Therefore, a conventional system would require up to 30% smaller capacity when compared with the total installed plant of SP + 7HP = 13HP. The current spit air conditioning systems. The diagram maximum simultaneous load on the whole building shows a typical building with a morning peak heat occurs at noon and is equal to 10HP of unit load on the east zone equivalent to a BHP unit capacity. A Set-Free System of 10HP can Inthe afternoon a peak occurs on the west zone therefore be selected, and this capacity can be equivalent to a 7HP unit directed either to the east or west zone as dictated ‘by the system controls. Saving in installed plant = BAD x00 258 Example of Air Conditioning for Bullding Load of East Zone Total Load _/toad of West Zone Load Time ‘Current Type--Selection by Total Capacity of Each Maximum Loed {= A+ 8) 1 SET-FREE-----Selection by Total Load which Occurs Simultaneously As: C=: 080 t0.085 ‘Since partial operation is obtained due to plural indoor wits the outdoor unt eapecty ean be selected according 1o the to tal load of & building in’ day. sete Supls retigeran ncodng othe od of ach (oad dversiy = 38 207 10HP- Olo HP) [2 HP} HP) + [2.5 HPI 2.5 HP][2 HP] = 13 HP East Zone West Zone (HP) HP) Indoor Unit Capacity (Equivalent HP) 2 HITACHI Great Power Saving Due to Heat Recovery System {FX only) ‘ Independent Cooling or Heating Operation ‘The FX system consists of multiple indoor units, ‘Multi-Kits, CH unit and one outdoor unit. According ‘0 heat load conditions, refrigerant flow is changed by activation of the CH units, and cooling operation is available independently Therefore, this system offers great power saving ‘due to a heat recovery system when heating load and cooling load are balanced. (CH Unit to Change Refrigerant Cycle f o4 Faing Weaina | ftiay awd nde, Cos MAINLY COOLING EVENLY COOLING AND HEATING ‘i Accmiso E Comores pos EE canto ae Lom \ i= casoien : r | f it th yf Goel) tol) bol) oly Gacy catse Casing eng MAINLY HEATING “hcominar Etomgrte conn mn ia ox tow) osteo rr =a r hoi i i Ail Alt Nolet er | if Bit HITACHI Friendly Sound [FS2 & FX] Resulting from the careful analysis of sound source, ‘atop class low sound operation on indoor units and ‘outdoor units has been achiaved, Fan Shroud Fan Motor Heat Exchanger: Inverter Compressor Outdoor Units. Lower Sound Operation during Night Time [FS2 & FX] “Through computer simulation of fluid turbulence Inverter, operation sound has been reduced, Which is the main source of unwanted noise, and by Friendly fo people and the environment alike, a low visual observation of fluid flow, operation sound has sound operation design has been obtained. been thoroughly analyzed. By improvernent of the cabinet structure and fan shape, and by the adoption of a new material and ‘Comparison of Operation Sound at 380V Unit: BA) ‘Outdoor Unit (HP) FX FS2 5 SAAT 3ara6 8 87/50 56/49 10 58/52 57/51 NOTE: ‘Operation Sound increases 1 dB(A) at 415V. 4 HITACHI FEATURES: Low Sound by IPM Control (FS2]/IGBT Control [FX] ‘The HITACHI Semi-conductor Technology inverter utilizing a high speed switching element was Deleted Unwanted Step Sounds introduced. Due to the new inverter, the step In the previous inverter-criven units, specific step sounds were deleted and also, electromagnetic ‘sounds occurred when the frequency was changed. sounds have been remarkably reduced, In order to delete step sounds, the IPM /IGBT © IPM Control (for FS2 System) © IGBT Control (for FX System) Previous TPM /IGBT Inverter Inverter LL | diode ave a |Medute Pattern IPM/IGBT 7 say Inverter JU Moro Computer Bbits 16 bits Controller Garrod Frequency 800~ Compressor 1.200H2 6.250H2 IPM Inverter: Intelligent Power Module IGBT Inverter: Insulated Gated Bipolar Transistor HITACHI 5 FEATURES Low Operation Sound Resulting from New Fan Shape and Propeller Fan Material |FS2 & FX) ‘The most appropriate fan shape for smooth airflow prevents turbulent flow, This combination has has been researched. Consequently, a new fan resulted ina low operation sound which was almost shape has been developed to minimize air impractical in the previous units. turbulence around the propeller fan. Also, a new ‘material of MRP (Mica polypropyiene) which ‘minimizes vibration characteristics against vibration sound has been adopted, and a laminated suriace Propeller Fan Low Sound Operation by Low Noise Fan Motor (FS2 & FX] In order to minimize electromagnetic sounds, without decreasing the operation performance. research was thoroughly performed on the materials Also, a non-resonance suspension structure has 10 be used for the assembled fan motor. ‘been adopted to support the fan motor. Due to this Consequently, aluminum die-casting was selected structure, the vibration sound has been minimized. and a low sound operation has been achieved HITACHI Specific Shroud for Propeller Fan (FS2 & FX) [A shroud allowing smoother air low has been has been minimized and the operation sound has Improved also to lower sound. By three dimensional been remerkably reduced. Also, by changing the {luc fow simulational experiments, anew slant cut direction of airflow fam 100" to 40" and by type shroud has been developed providing changing the position ofthe fan, sound difusion has homogenous ait flow. As a result of his new been minimized, shroud, sound generated by uid flow turbulence Primary Air Discharge Angle 100" Primary Ar Discharge Angle 40" Previous Outdoor Unit (HEM Series} [New Outdoor Unit HITACHI Wide Cooling Operation (FS2 & FX] ‘This unit has been designed for cooling operation This feature enables cooling to be obtained even in under low ambient temperatures down to -S. winter on buildings with high internal heat gains due 10 lighting, people and machines, particularly in ‘areas such as shops, lecture rooms, data processing areas etc “8 Outdoor Air Dry But Tempera Fs2, ture FX ce) Series 15 25 (°C we) Indoor Suetion Air Wet Bulb Temperature HITACHI 7 FEATURES ®] Greatly Minimized Piping Work by HITACHI “Uni-Plping System” [FS2.& FX] The new “Uni-Piping” where the same size pipe as the main refrigerant pipe can be utilized, has been developed, except for 10HP system. Due to this single size, piping work has been greatly simplified. Aso, from the point of design, complicated piping selection has been minimized, Only two refrigerant pipes in the refrigeration cycle are required. Various piping connection sets are also available according to field requirements. Due to these improvements, various problems during installation have been solved. The new HITACHI “Uni-Piping System” is the epoch-making system which saves installation time and labour. Possible to Extend Longer Refrigerant Piping to Meet Needs for Tall Bulldings [FS2 & FX) ‘The new systems actual piping can be extended up to 100 meters, where the previous model was only ‘up to 80 meters (HEM Series) ft between the indoor and outdoor unit can also be ‘extended up to 50 meters, where the previous system was only to 40 meters. Algo, the lift between indoor units has been improved from 4 meters to 15 meters. Therefore, more variable piping systems are available, The liquid piping for the indoor units up to 2HP has been down-sized to 6.35mm as the outer diameter. Also, gas piping for the indoor units up to 1.5HP has been down-sized to 12.7mm as the outer diameter, resulting in simplified refrigerant piping work and less use of refrigerant. HITACHI (FEATURES: Grade-up on Flexibilty and Comfortabilty [FS2 & FX] Able to Establish Alr Conditioning Systems for Various Requirements (1) Amaximum piping longth of 100 meters and 2) Uiiizing the SO (suetonveischarge ait ‘maximum it of 50 meters between the indoor temperature) contralto maintain the most ‘units and outdoor unt are applicable appropriate refrigerant flow, a maximum it of 15 meters, which is almost equivalent to a 4 floor height, bolween indoor units is avaiable, Piping System for FS2 Series ‘System Example 1 Une Branch System ‘Systom Example 2 Header Branch System System Example 3 ‘Combination Branch System HITACHI ° FEATURES Piping System for FX Series ‘System Example 1 Line Branch System B cuunit Operation in the save mode System Example 2 Header Branch System DB cH unit System Example 3 ‘Combination Branch System > cHunit HITACHI Piping System for FS2 Series Line Branch [Applicable Model of Mult-Kit 1 Piping Size Mode! A B-D E a bre [Ras-srs2| E-s2s2 | €-5252 | €-52SE 91905 | 919.05 nasersz| eevsz | eezse | ease | 9222 | 222 £-10283 sa PAS-tOFSzi4E-I97Se5| Eazse | Eazse | 58, | 9222 ca De E cent Mees Indoor Unit 3K In case of connection with 2 indoor units, use E - 102SE3, Header Branch] [acs icabie Model of Mult-Kit Gas Piping Mode! [3,4 Branchos]3-6 Branches)5-8 Branches] 7, @Branches Size @ RAS-5FS2 | _E-SASE = E585, = 919.05, RAS-8FS2 #222 - E-96se3 - e-eeses [9254 RAS-10FS2 (aes) Outdoor Unit a SS 2&2 > Indoor Unit HITACHI "

You might also like