MANILA TECHNICAL SYSTEM CO.

JOB HAZARD AND RISK ASSESMENT( JHRA)

TITLE : FRAME AND GLASS INSTALLATION

Equipment or
Job Steps / Tasks Hazards & Risk Person at Risks Action Plans/ Mitigating System / Control
Tools Used

1.0 BEFORE INSTALLATION

CHECK WINDOW OPENING IF ITS ON HIGH LEVEL


a. Inspect the window
L-square/Level Person involve in the PREPARE/SCAFOLDS IF ITS NESSESARY/COMPLETE
opening if it is acceptable for
Bar/Meter Tape Falling objects activity/Passerby P.P.E.LEAD MAN SHOULD BE PRESENT DURING THE
installation.
INSPECTION

L-square/Level Falling CLEAR THE AREA /REMOVE ALL POSSIBLE


b. Surface Preparation
Bar/Meter Tape Object/Eye
All employees
OBSTRUCTION
Injury
2.0 DURING INSTALLATION

a. Put a marked on the


L-square/Level
window opening with the PUT A HOLDER OR WIRE ON YOUR TOOLS TO
Bar/Meter Falling Object Workers/Passerby
approved spacing of fixing PREVENT FALLIN TOOLS.
Tape/Pencil
(Chemical Bolt)

b. Drill the marked approved Eye


spacing using 8mm Masonry Electric Drill injury/Electrocu Workers/Passerby WEAR DUST MASK WHILE USING BORING DRILL
Drill bit. tion
c. Clean the boring holes WEAR DUST MASK WHILE USING DRILLING TO
using the required cleaning Air pump Eye injury Workers/Passerby
MAKE BORING HOLES .GOGLES AS WELL IF NEEDED
material.

d. Apply the chemical using Person involve in the CLEAN ALL EXCESSIVE CHEMICAL ON AREA TO BE
the chemical gun. Sealant Gun Skin rashes activity APPLIED. APLY ONLY EXACT AMOUNT OF CHEMICAL

e. Put the window frame and


PUT AN EXTRA ROPE TO HOLD THE FRAME TIED
check the level, insert the Level bar/Plumb
Falling object All employees THEM UP TO ENOUGH HOLD THE FRAME TO BE
6mm diameter bolt and fixed Bob
INSTALLED/EXTRA MANPOWER AS WELL
it.

f. Allowed the chemical bolt Falling of LET THE CHEMICAL TO DRY BEFORE INSTALLED THE
to dry at least overnight. Masking Tape header bolts All employees BRACKET

3.0 GLASS INSTALLATION

a. Put the setting block along BE SURE THAT THE GLASS HOLDER ARE IN GOOD
Rubber Mallet Falling object All employees
the perimeter then tight it. CONDITION.

b. Set the glass into the


setting block and make it sure
that heat strength glass is INSTALLER SHOULD BE TRAINED AND WELL
facing outside and fully ORIENTED TO PREVENT BREAKAGE.PUT AN EXTRA
Falling RUBBER ON THE CORNER OF THE GLASS.THIS GLASS
tempered glass is facing Glass Sucker object/Glass All employees
inside. IS BONDED TYPE WHICH MEAN THIS GLASS ARE
Breakage PREASURIZED.SAFETY OFFICER SHOULD BE PRESENT
DURING THE ACTIVITIES OR INSTALLTION
c. Sealant the perimeter of
the glass and fixed it with the Sealant Falling CHECK THE AREA BEFORE APLY. SHOULD BE CLEAN
glazing bid and gasket. Gun/Rubber Object/Eye All employees FREE FROM ALL FOREIGN MATERIALS.DONT FORGET
Mallet Injury ALL THE CLOSSING GASKET TO, PUT ON.

4.0 SEALANT APPLICATION

a. Clean the perimeter of the Choke/Eye Person involve in the


opening using the approved Paint Brush APLY I.P.A AGENT ON perimeter area
cleaning agent. Injury activity/workers

Rubber
b. Press backing rod into Hand Person involve in the CHECK THE BACKING ROD ON EXACT AREA OR
Mallet/Cutterblad
place. Injury/Wounds activity/workers TOLERANCE AQUIRED
e

BE SURE THAT THE SEALANT IN GOOD CONDITION IT


c. Apply the silicon using the Sealant gun Stinking Person involve in the VARIES DEPEND ON NOZZLE TYPE.SHOUL BE APLY
silicon gun. injury/workers
RAPIDLY.

5.0 TESTING/INSPECTION

a. The testing is conducted


and supervised by client Pressure water Slippery Person involve in the WE ARE APYING ESMT E 1105 LEAKTEST SYSTEM
gauge activity/employees
representative.

PREPARED BY: NOTED BY:


SILVERIO R. CAYAN JR. DANIEL CANDELARIA
MTCS-SAFETY OFFICER MTSC-PROJECT IN CHARGE