You are on page 1of 8

ICO3S - 2/2, 3/2 or 5/2 poppet valves

Electromagnetically actuated, direct solenoid operated

>> Port size: 1/4”... 1/2” >> Control of pneumatic


(ISO G / NPT) or hydraulic operated
Namur or manifold equipment
>> Direct acting >> Certifications: ATEX,
solenoid valve CSA, TR CU, IECEx,
>> High flow FM, CSA, CRN, CCOE,
IN-METRO, KOSHA,
>> 12 bar inlet pressure NEPSI, PESO (CCOE),
>> Reliable and long life, Japan ISHL
ideal for a one time >> Environmental
installation protection: NEMA 4X,
IP66/X8

Technical features
Medium: Flow: Temperature: Materials:
Hydraulic and pneumatic – 0,6 Cv (8,7Kv) ... 3.3 Cv (46.4 Kv) Media: Valve body, trim, coil housing and
customer to specify and confirm Port size: -55 ... +90°C (-67 ... 194°F) top cover:
compatibility G 1/4, 1/2 NPT, G 1/4, G 1/2 Ambient: stainless steel 1.4404 (316 L)
Operation: NAMUR or manifold versions See table on page 2 O-rings seats & seals: NBR
Direct solenoid operated Operating pressure: Air supply must be dry enough to
poppet valves 0 ... 12 bar (0 ... 174 psi) avoid ice formation at temperatures Other seal materials available
Mounting position: below +2°C (+35°F). on request
Solenoid vertical

5/19
Our policy is one of continued research and development. We therefore reserve the right to amend, without notice,
the specifications given in this document. (2012 - 5197d) © IMI Precision Engineering, Thompson Valves Ltd. en 5.7.540.01
ICO3S - 2/2, 3/2 or 5/2 poppet valves
Electromagnetically actuated, direct solenoid operated

Technical data – standard models with conduit connection M20 x 1,5


Symbol Port Function Operating Manual ATEX Power Ambient Weight Dimension Model
size pressure override/ certification consumption temperature
(bar) reset at 24 Vdc (W) (kg) No.
2 1/4 NPT 2/2 NC 0 ... 12 Without Ex II 2 GD, Exd IIC 3 T6 (-55 … +50°C), T4 (+90°C max) 2,0 1 Y011AA1H1BS
G 1/4 2/2 NC 0 ... 12 Without Ex II 2 GD, Exd IIC 3 T6 (-55 … +50°C), T4 (+90°C max) 2,0 1 Y011AE1H1BS
1

2 1/4 NPT 2/2 NC 0 ... 12 JSMO*1) Ex II 2 GD, Exd IIC 3 T6 (-55 … +50°C), T4 (+90°C max) 2.0 2 Y011SA1H1BS
G 1/4 2/2 NC 0 ... 12 JSMO*1) Ex II 2 GD, Exd IIC 3 T6 (-55 … +50°C), T4 (+90°C max) 2.0 2 Y011SE1H1BS
1
1/4 NPT 3/2 UNI 0 ... 12 Without Ex II 2 GD, Exd IIC 3 T6 (-55 … +50°C), T4 (+90°C max) 2,0 3 Y013AA1H1BS
2
G 1/4 3/2 UNI 0 ... 12 Without Ex II 2 GD, Exd IIC 3 T6 (-55 … +50°C), T4 (+90°C max) 2,0 3 Y013AE1H1BS
V-32C-E-F
1/2 NPT 3/2 UNI 0 ... 12 Without Ex II 2 GD, Exd IIC 7,8 T6 (-55 … +50°C), T4 (+90°C max) 2,5 4 Y013AA3H1BS
1 3
G 1/2 3/2 UNI 0 ... 12 Without Ex II 2 GD, Exd IIC 7,8 T6 (-55 … +50°C), T4 (+90°C max) 2,5 4 Y013AE3H1BS
2 1/4 NPT 3/2 UNI 0 ... 12 JSMO* Ex II 2 GD, Exd IIC 3 T6 (-55 … +50°C), T4 (+90°C max) 2,5 5 Y013SA1H1BS
2
V-32C-EH-F
G 1/4 3/2 UNI 0 ... 12 JSMO* Ex II 2 GD, Exd IIC 3 T6 (-55 … +50°C), T4 (+90°C max) 2,5 5 Y013SE1H1BS
1 3
1 3

22 1/4 NPT 3/2 UNI 0 ... 12 TPMR*1) Ex II 2 GD, Exd IIC 3 T6 (-55 … +50°C), T4 (+90°C max) 2,5 6 Y013TA1H1BS
GV-32C-ER-F
1/4 3/2 UNI 0 ... 12 TPMR*1) Ex II 2 GD, Exd IIC 3 T6 (-55 … +50°C), T4 (+90°C max) 2,5 6 Y013TE1H1BS
11 33
1/4 NPT 3/2 UNI 0 ... 12 PBMO*1) Ex II 2 GD, Exd IIC 3 T6 (-55 … +50°C), T4 (+90°C max) 2,0 7 Y013PA1H1BS
2
G 1/4 3/2 UNI 0 ... 12 PBMO*1) Ex II 2 GD, Exd IIC 3 T6 (-55 … +50°C), T4 (+90°C max) 2,0 7 Y013PE1H1BS
1/2 NPT 3/2 UNI 0 ... 12 PBMO*1) Ex II 2 GD, Exd IIC 7,8 T6 (-55 … +50°C), T4 (+90°C max) 2,5 8 Y013CA3H1BS
1 3
G 1/2 3/2 UNI 0 ... 12 PBMO*1) Ex II 2 GD, Exd IIC 7,8 T6 (-55 … +50°C), T4 (+90°C max) 2,5 8 Y013CE3H1BS

2 1/2 NPT 3/2 UNI 0 ... 12 PBMR*1) Ex II 2 GD, Exd IIC 3 T6 (-55 … +50°C), T4 (+90°C max) 2,8 8 Y013PA3H1BS
G 1/2 3/2 UNI 0 ... 12 PBMR*1) Ex II 2 GD, Exd IIC 3 T6 (-55 … +50°C), T4 (+90°C max) 2,8 8 Y013PE3H1BS
1 3

Manifold 3/2 UNI 0 ... 12 Without Ex II 2 GD, Exd IIC 3 T6 (-55 … +50°C), T4 (+90°C max) 2,8 9 Y013AKFH1BS

3 1 2

2 2 1/4 NPT NAMUR 3/2 UNI 0 ... 12 PBMR*1) Ex II 2 GD, Exd IIC 3 T6 (-55 … +50°C), T4 (+90°C max) 2.5 10 Y013PNAH1BS
G 1/4 NAMUR 3/2 UNI 0 ... 12 PBMR*1) Ex II 2 GD, Exd IIC 3 T6 (-55 … +50°C), T4 (+90°C max) 2.5 10 Y013PNEH1BS
1 3

4 2 1/4 NPT 5/2 UNI 0 ... 12 Without Ex II 2 GD, Exd IIC 7,8 T6 (-55 … +50°C), T4 (+90°C max) 2,8 11 Y015AA1H1BS
V-52-E-F
G 1/4 5/2 UNI 0 ... 12 Without Ex II 2 GD, Exd IIC 7,8 T6 (-55 … +50°C), T4 (+90°C max) 2,8 11 Y015AE1H1BS
513 NAMUR 5/2 UNI 0 ... 12 Without Ex II 2 GD, Exd IIC 7,8 T6 (-55 … +50°C), T4 (+90°C max) 2,3 14 Y015ANAH1BS
44 22 1/4 NPT 5/2 UNI 0 ... 12 PBMO*1) Ex II 2 GD, Exd IIC 7,8 T6 (-55 … +50°C), T4 (+90°C max) 2,3 12 Y015CA1H1BS
G 1/4
V-52-EH-F 5/2 UNI 0 ... 12 PBMO*1) Ex II 2 GD, Exd IIC 2 T6 (-55 … +50°C), T4 (+90°C max) 2,3 12 Y015CE1H1BS
551133

4 2 1/4 NPT 5/2 UNI 0 ... 12 PBMR*1) Ex II 2 GD, Exd IIC 2 T6 (-55 … +50°C), T4 (+90°C max) 2,5 13 Y015PA1H1BS
4 2
G 1/4
V-52-EH-F 5/2 UNI 0 ... 12 PBMR*1) Ex II 2 GD, Exd IIC 7,8 T6 (-55 … +50°C), T4 (+90°C max) 2,5 13 Y015PE1H1BS
513
513
*1) PBMR = Push button manual reset, PBMO = Push button manual override, JSMO = Jack screw manual override,
TMRP = Tamperproof manual reset button

Our policy is one of continued research and development. We therefore reserve the right to amend, without 
en 5.7.540.02 notice, the specifications given in this document. (2012 - 5197d) © IMI Precision Engineering, Thompson Valves Ltd. 5/19
ICO3S - 2/2, 3/2 or 5/2 poppet valves
Electromagnetically actuated, direct solenoid operated

Option selector Y˙1˙˙˙˙˙˙˙S


ATEX certification Substitute Voltage / Signal Substitute
Ex d O 24 V d.c. B
Ex mbe Z 50 V d.c. C
Ex ia* X 110 V d.c. D
Operation Substitute 125 V d.c. E
2/2 NC 1 24 V a.c. G
2/2 NO 2 110 V a.c. J
3/2 3 220 /240 V a.c. (240 V) M
5/2 5 120 V a.c. T
Operation Substitute Conduit / Signal connection Substitute
Automatic A 20mm x 1.5mm ISO (F) 1
Push button manual override C 1/2 NPT (F) 2
Push button manual reset P Seat /seal material Substitute
Tamper proof manual reset T Nitrile (-55° ... +90 °C) H
Jackscrew manual override S FKM (-20° ... +90 °C) V
Port size Substitute
1/4 NPT A1
G 1/4 E1
1/2 NPT A3
G 1/2 E3
NAMUR NA
Manifold KF
* For Zone 0 - see separate catalogue
section.

Our policy is one of continued research and development. We therefore reserve the right to amend, without
5/19 notice, the specifications given in this document. (2012 - 5197d) © IMI Precision Engineering, Thompson Valves Ltd. en 5.7.540.03
ICO3S - 2/2, 3/2 or 5/2 poppet valves
Electromagnetically actuated, direct solenoid operated

Dimensions Dimensions in mm
Projection/First angle
1 2
ø59 ø59
Y 47 Y 77
28

28
22

22
157

157
113,6

113,6
50,3
A 2

50,3
2
15,3 12
1
25,8

15,3 12
A
1

25,8
15,8

15,8
25,5 50

22
11
27
25,5 50
11
27

47

3 4

47 ø 58 47 ø58

1 1
28

28
2 2

22
22
157

187

3 3
2
39

1
27,5

2
26
6

16

66
42

11 25,5
42

1
15,5

18
18

27
6,5

50 44 26
65

1 Conduit connection M20 x 1,5 or 1/2 NPT


2 External earth
5 Jack screw manual override (JSMO)

Our policy is one of continued research and development. We therefore reserve the right to amend, without 
en 5.7.540.04 notice, the specifications given in this document. (2012 - 5197d) © IMI Precision Engineering, Thompson Valves Ltd. 5/19
ICO3S - 2/2, 3/2 or 5/2 poppet valves
Electromagnetically actuated, direct solenoid operated

Dimensions in mm
Projection/First angle
5 6
47 ø 58 47 ø 58

1 1

28
28
2 2

22

22
157
157
3 3
2 2

39
39
1 1
27,5

27

26
26

15

16
6
6

16
24

11 25
15,5

11
11 5 25,5 27
27 50
50

7 8

47 ø 58 47 ø58

1 1

28
28

2 2

22
22

187
157

3 3
2
39

1 2
27

26
15

16
6

66
42
42

11 25 1
3

3
13 18
18
6,5

27
50
44 3 26
65

1 Conduit connection M20 x 1,5 or 1/2 NPT


2 External earth
3 Push button manual reset (PBMR)
4 Push button manual override (PBMO)
6 Tamer proof manual reset (TPMR)

Our policy is one of continued research and development. We therefore reserve the right to amend, without
5/19 notice, the specifications given in this document. (2012 - 5197d) © IMI Precision Engineering, Thompson Valves Ltd. en 5.7.540.05
ICO3S - 2/2, 3/2 or 5/2 poppet valves
Electromagnetically actuated, direct solenoid operated

Dimensions in mm
9 Projection/First angle

47 ø58

28
2

22

157
6,5
3
2

39
1

26
25

16
ø5
ø8,8

51 38
51

10

47 ø 58

1
28

2
22

157

1
39
5,5
36

3
14

16
12
12

19,5 1,6 3 51
32 64

1 Conduit connection M20 x 1,5 or 1/2 NPT


2 External earth
3 Push button manual reset (PBMR)

Our policy is one of continued research and development. We therefore reserve the right to amend, without 
en 5.7.540.06 notice, the specifications given in this document. (2012 - 5197d) © IMI Precision Engineering, Thompson Valves Ltd. 5/19
ICO3S - 2/2, 3/2 or 5/2 poppet valves
Electromagnetically actuated, direct solenoid operated

Dimensions in mm
11 12 Projection/First angle

47 ø58 ø59 77
Y
1

28
2

22

177

177
5

149
4
1

35
59

12
W

71
2
43

58,5
36

3
20

34,5
12

50 30

11,5
12
25 51,2
11
27

13

47 ø58

1
28

2
22

177

5
4
1
59

2
43

36

3
20

11 12

50 4 30

1 Conduit connection M20 x 1,5 or 1/2 NPT


2 External earth
3 Manual override PBMO
4 Manual override PBMR

Our policy is one of continued research and development. We therefore reserve the right to amend, without
5/19 notice, the specifications given in this document. (2012 - 5197d) © IMI Precision Engineering, Thompson Valves Ltd. en 5.7.540.07
ICO3S - 2/2, 3/2 or 5/2 poppet valves
Electromagnetically actuated, direct solenoid operated

Dimensions in mm
14 47 ø58
Projection/First angle
1

28
2

22

177
5
4
1

59
5,5
46

2
34

36
3
22

12
19,6 1,6 51
3

32

1 Conduit connection M20 x 1,5 or 1/2 NPT


2 External earth

Warning
These products are intended for use in industrial compressed air The system designer is warned to consider the failure modes of all
systems only. Do not use these products where pressures and component parts used in fluid power systems and to provide adequate
temperatures can exceed those listed under safeguards to prevent personal injury or damage to equipment in the
»Technical features/data«. event of such failure.
Before using these products with fluids other than those specified, System designers must provide a warning to end users in the system
for non-industrial applications, life-support systems or other instructional manual if protection against a failure mode cannot be
applications not within published specifications, consult adequately provided.
IMI Precision Engineering, Thompson Valves Ltd. System designers and end users are cautioned to review specific
Through misuse, age, or malfunction, components used in fluid warnings found in instruction sheets packed and shipped with these
power systems can fail in various modes. products.
For further information please see Functional Safety Manual MI0560.

Our policy is one of continued research and development. We therefore reserve the right to amend, without 
en 5.7.540.08 notice, the specifications given in this document. (2012 - 5197d) © IMI Precision Engineering, Thompson Valves Ltd. 5/19