You are on page 1of 5

1/27/2016

FACILITIES CONSIDERATIONS
1. Well-designed facilities
ELEMENTS OF GOOD
– Décor is generally plain white or off-white
SENSORY PRACTICE – Lighting is controlled often
– Good ventilation, free from extraneous odors
– Quiet, free from extraneous noises

2 3

FACILITIES CONSIDERATIONS
2. The concept of the booth

– Multiple individuals can evaluate the same product


at the same time in the same room
– No panelist interaction
– Booths are adjacent to, but physically separated
from a preparation area
– Sinks and running water can be included in each
booth

4 5

FACILITIES CONSIDERATIONS
3. Descriptive testing/training area

– Conference room type setting with large table and


comfortable chairs
– Access to visual aids
– Access to an adjacent test kitchen for product
preparation

1
1/27/2016

6 7

SAMPLE CONSIDERATIONS
General variables include:

• Sample temperature
• Sample size
• Sample preparation methods
• Time after cooking to serve

8 9

EXPERIMENTAL DESIGN PANELIST CONSIDERATIONS


CONSIDERATIONS
1. Trained or untrained?
• Bias-free blinding codes to identify samples (use of 2. Screening
random 3-digit numbers is the industry standard) 3. Motivation
– General principle: All panelists need some kind of
• Presentation orders are either counterbalanced or incentive.
randomized 4. Human subjects protocols
– Participation is voluntary
• Type of statistics that will be applicable to the test – They have a right to terminate participation at any time
results should be part of the test design – Any potential risks and/or benefits have been explained

10 11

Conditions for judging


• Best time for sensory testing: 10-11am and 3-4pm
• At least 1 hour prior to sensory testing, panelists are
ADVISED NOT TO:
– Eat
– Smoke
– Drink liquor
– Chew gum
– Brush teeth
• Verbal communication should be avoided
• Avoid the use of strong perfumes

2
1/27/2016

1. Prepare a master sheet.


• Provides an organized record of the sensory test
• Contains all the necessary data on the conducted test
General Procedure
How to prepare a master sheet:
for Setting Up a a. Write all the necessary information about the test to
be conducted.
Sensory Test b. Assign a 3-digit random number code to each sample
to be served.
c. Determine the random order of serving of samples
for each judge.

2 3

Notes on the 3-digit random codes

• May be obtained from the Table of Random Numbers


or from a calculator (RAN#)

• Done to minimize tendency to associate


superiority/inferiority of samples

• Avoid the use of double or triple numbers

• Avoid the use of numbers with “13”

4 5

Notes on the assignment of random


order of serving
2. Code sample containers.

• The Table of Permutations of Numbers 1 to 9 may be • Must be labeled with the 3-digit random codes
used assigned to the sample (indicated in the master sheet)

• The order of serving is randomized to prevent the • Use odorless ink in marking
tendency of the judge to rate the 1st sample higher
thinking that it is more superior • Use the same ink color for all samples for all judges

3
1/27/2016

6 7

3. Prepare a score sheet.


• Contains the instruction/s as to how the judge should
evaluate the samples

• Must be designed and reproduced before the conduct


of the sensory test

• Must also contain: judge #, testing date, sample, title


of sensory test, random codes of samples arranged in
the order indicated in the master sheet

8 9

5. Pour/place samples in
4. Prepare a table mark-up.
the containers.
• An enlarged master sheet
• Liquid – pour approx. 15-20mL
• Data on the master sheet are enlarged on a table, but
instead of simply copying the codes, the coded • Solid – place approx. 20g or 1cm3
sample containers are placed on the table in the same
manner as they appear on the master sheet • Sample should be homogeneous

Note: The order of serving is not yet being applied when • Sample should be tested at the
preparing the table mark-up. temperature at which it is normally
consumed

10 11

6. Set up trays.
• The samples for each judge are placed on a tray

• The samples are arranged according to the order of


serving indicated in the master sheet (NOTE: Samples
are evaluated from left to right)

• Trays contain the ff: samples, score sheet, cup of water


for rinsing, extra cup for spitting (if necessary)

4
1/27/2016

12 13

7. Serve trays when the 8. Give the judge sufficient time to


evaluate the samples.
judge is ready.
9. Decode the score sheets and
• The serving area and evaluation area is equipped with
a signal system. Know the appropriate signal indicating indicate the responses in the
that the judge is ready to be served. master sheet.

10. Determine the statistical


significance of the test.

You might also like