Professional Documents
Culture Documents
Technical information
PRP Power (kVA) 81,8
Standby Power (kVA) 90
PRP Power (kW) 65,4
Standby Power (kW) 72
Mechanical Structure SOUNDPROOFED
Noise Level
Acoustic pressure [LpA] (dBA @7m) 69
Acoustic power [LwA] (dBA) 95
Standard supply
Galvanised soundproofed canopy
Cleaning hatch in fuel tank
Página 1 de 3
Consumption
Engine
Brand PERKINS
Model 1104A-44TG2
No. of cylinders 4
Engine Capacity (c.c.) 4400
Bore (mm) 105
Stroke (mm) 127
Compression ratio 17,2:1
Water cooled
Speed (r.p.m.) 1500
Mechanical Net Power (kWm) 79,1
Fuel tank capacity (l) 230
Cooling System
Flow of air from fan (m3/min) 89
Lubrication System
Oil sump capacity (l) 8
Maximum oil consumption (% fuel consumption) 0,15
Electrical system
Number of batteries 1
Battery 12V 60 Ah. 680 A
Exhaust System
Input diameter (") 3
Output diameter (") 3,5
Body diameter (mm) 280
Exhaust length (mm) 1.090
Tª gas emission (ºC) 580
Gas flow (m3/min) 13,3
Alternator
Model ECP34-1S
Electronic Regulation
AVR DSR
Power (kVA) 94,7
Electric Panel
Control Instruments
Control Card DEEP SEA 7320
Auto Start-up. mains failure
Página 2 de 3
Electric Panel
Manual start-up
Remote start-up
Alarms
Start-up failure
Battery charge failure
Low oil pressure
High engine water temperature
Low Fuel Level
Low Radiator water level
Emergency Stop
Overspeed
Standby Gen-sets
Auto/Manual Function
LED indicators MAINS/GENSET switch
Remote control software
RS 232 communication port
RS 485 communication port
Protection Devices
Emergency stop button
Circuit breaker 4P 125A R
ATS (optional) 4P 125A (230V) - CC
Grupos Electrógenos Gesan reserves the right to modify any characteristic without prior notice. Photos based on product
standards, being possible to add optional elements.
Página 3 de 3