You are on page 1of 2

NO

DATA SHEET I-FD-4150.50-6270-255-PEN-001


CLIENT: SHEET
TRANSPORTADORA GASENE S.A./U. GÁS&ENERGIA 1of 2
JOB:
CABIÚNAS – VITÓRIA GAS PIPELINE
AREA:
CABIÚNAS STATION
TITLE:
ENGENHARIA CYCLONE/CARTRIDGE FILTER

REVISION INDEX
REV DESCRIPTION AND/OR AFFECTED SHEETS

0 FIRST ISSUE
A REVISED ITEMS 06, 08 AND 17, ACCORDING TO COMMENTS OF G&E

REV. 0 REV. A REV. B REV. C REV. D REV. E REV. F REV. G REV. H


DATE NOV-16-05 AUG-24-06
DESIGN ETEG / EDUT ETEG / EDUT
EXECUTION CARVALHO CARVALHO
CHECK SCOFIELD FURLEY
APPROVAL SIMON SIMON
THE INFORMATION CONTAINED IN THIS DOCUMENT IS PETROBRAS PROPERTY AND MAY NOT BE USED FOR PURPOSES OTHER THAN THOSE SPECIFICALLY INDICATED HEREIN.
FORM STANDARTIZED BY STANDARD PETROBRAS N-381-REV.G.
NO REV.
DATA SHEET I-FD-4150.50-6270-255-PEN-001 A
JOB: SHEET:
CABIÚNAS – VITÓRIA GAS PIPELINE 2 of 2
TITLE:

CYCLONE/CARTRIDGE FILTER
GENERA
01 TAG FT-4150.50551A/B
02 QUANTITY 02
03
04 FLUID NATURAL GAS
05 MOLECULAR WEIGHT 16.1 to 17.9
PROCESS VALUES

06 MAXIMUM FLOW, m³/d @ 20ºC and 1atm 20,000,000


07 MINIMUM FLOW, m³/d @ 20ºC and 1atm 3,000,000
08 MINIMUM OPERATING PRESSURE, kgf/cm² gauge 50
09 MAXIMUM OPERATING PRESSURE, kgf/cm² gauge 100
10 DESIGN PRESSURE, kgf/cm² gauge 100
11 MINIMUM TEMPERATURE, ºC 20
12 MAXIMUM TEMPERATURE, ºC 42
13 DESIGN TEMPERATURE, ºC 55
14 TYPE VERTICAL
15 MANUFACTURER
16 MODEL
17 NOMINAL DIAMETER, in 24
18 1st STAGE: CYCLONE
19 2nd STAGE: CARTRIDGE
20 DESIGN PRESSURE, kgf/cm² gauge
21 DESIGN TEMPERATURE, ºC
22 HYDROSTATIC TEST PRESSURE, kgf/cm² gauge
23 ANSI CLASS: 600#
FILTER

FLANGE TYPE: RF
24 FILTRATION EFFICIENCY, % 99.98
25 DUST RETENTION SIZE (ABSOLUTE): 5μm
27 DUST DRUM CAPACITY
MAXIMUM DIFFERENTIAL PRESSURE, kgf/cm² 0.5
BODY MATERIAL:
33 SIZING STANDARD: API 521
RELIEF

34 CONDITIONS: FIRE
ENDS: FLANGES
35 SET POINT, kgf/cm² gauge: 104
36 DRAIN: (note 3) 3"
37 VENT: 1"
40 APPLICABLE NOTES: 1 to 7
41 NOTES:
1- SEE I-ET-4150.62-6521-200-PEN-001, STANDARD DE1, FOR MATERIAL SPECIFICATION;
2- ALL BLANK SHALL BE FILLED IN BY THE MANUFACTURER;
3- THE FILTER DRAIN MUST HAVE TWO BLOCK VALVE IN SERIE;
4- ALL BODY CONNECTIONS MUST BE WELDED;
5- PRESSURE VESSELS WITH NOMINAL DIAMETER EQUAL OR GREATER THAN 2 INCHES AND CONTAINING GIRTHWELDS
MUST BE 100% INSPECTED BY RADIOGRAPHY, ACCORDING TO API 1104 CODE;
6- SEE I-ET-4150.62-6521-500-PEN-001 FOR NR-13 REQUIREMENTS;
7- THE FILTER MUST HAVE A QUICK OPENING CLOSURE.

You might also like