5.2 Display via light-emitting Table 15. Display via light-emitting diodes
diodes LED LED lights = display mode LED flashes = programming mode
Operating voltage is applied to pump unit and The value for PAUSE may be changed.
control unit. The system is in the PAUSE
state
Operating voltage is applied to pump unit and Value for CONTACT can be changed
control unit, system is in operating state
CONTACT (pump motor ON)
For system monitoring, a cycle switch is This mode of monitoring can be switched off in
used. Monitoring takes place at the the programming mode.
progressively-acting distributor while the COP = CS (monitoring is active)
pump is in operation. (CONTACT) COP = OFF (monitoring is switched off).
Pressure switch monitoring is not possible in Monitoring by pressure switch must not be
progressively-acting progressivelydistributor activated in progressively acting systems.
systems. COP = CS or COP = OFF
LED must not be ON.
The operating voltage is applied to the pump unit and control unit. The control unit is in
the operating state FAULT. The fault can be called up via the LED display and displayed
as error code after pressing of the pushbutton .
The sequence of operations is stopped.
Pump Running Time Settings: Pause Time is 1 Hour for all Installations
4 Indicates preselected pump running time
QJ240 - Torque Arm Excluded - 6.0 mins Example: Timer operation
QJ240 - Torque Arm Included - 6.5 mins
5 Example: System is in Pause mode, indication of current
QJ340 - Torque Arm Excluded - 7.5 mins tCO is not possible
QJ340 - Torque Arm Included - 8.0 mins
If the spec isn't covered in this list please ask Refer to notes along side.
the Design Department to Clarify. 7 Indicates system monitoring menu
Display mode Page 27
US
Table 17 continued
Step Key Display
8
.
Monitoring deactivated or or
(factory setting) monitoring via cycle switch Is not permitted for
Cycle Switch Monitoring should progressive systems!
be turned on. 9 Indicates operating hours
10/11
13/14
7.2 Changing the lubrication Table 19. Changing the lubrication interval times
interval times Step Key Display
1 Display flashes
Note concerning step 2: (Code 000, factory setting)
the manufacturer's code 000 has already been Press for more than 2s
changed, you have to select the new code with
keys and confirm it with key .
2 Automatically indicates first parameter
Example: „pause in timer operation“
Press briefly LED „PAUSE“ flashes
(confirm code)
1 Hour
Programming Page 29
US
Table 19 continued
Step Key Display
5 Indicates next parameter
„pump running time in timer operation“
Press briefly LED „contact“ flashes
(confirm new value)
7.3 Changing the system Table 20. Changing the system monitoring
monitoring Step Key Display
1 Display flashes
(Code 000, factory setting)
Press for more than 2s
4 Monitoring deactivated
(factory setting)
Press briefly
5
Press appropriate key
until
7.4 Changing the operating mode Table 21. Changing the operating mode
Step Key Display
1 Display flashes
(Code 000, factory setting)
Press for more than 2s
DO NOT CHANGE
Important!
Do not use the figures 321 as new code.
Press briefly
(confirm key number)
(Code 000, factory setting)
9 Faults
Check level in reservoir at regular 9.1 Displaying faults Before clearing the fault message,
intervals. If the reservoir has been determine and rectify cause of fault.
emptied completely, the entire Start display mode with one of the two keys The user himself shall be liable for
system must be bled after topping . any damage resulting from the
up. Operate until fault is displayed. (Table 25): operation of the vehicle without
lubrication.
All fault messages are displayed as a central
ized alarm via the light-emitting diode . 9.2 Clearing the fault message The time for which the control unit
When a fault message is output, the normal and the pump unit have been
sequence of operations is stopped by the All fault messages can be acknowledged and operated without lubrication is
control unit, and the fault concerned is stored cleared with key . When the unit is operated stored in an undeletable manner in
and displayed. The cause of the fault can be in the Timer mode, this can also be performed the EEPROM as fault hours Fh.
read on the display. This considerably facilitates via a connected external pushbutton.
the fault diagnosis. This function is available
only, if system monitoring is active, however.
Table 25. Displaying faults
Display Meaning
Fault Cycle Switch:
No signal from cycle switch during pump running time.
(see section 9.5 - block operation)
Fault Low Level:
Lubricant has dropped below minimum level in reservoir.
The further sequence of operations is stopped.