You are on page 1of 2

STRUCTURALANALYSIS & DESIGN

CODE AND SPECIFICATIONS:

The following structural codes and specifications shall be used in the structural analysis and design of the
reinforced concrete special moment resisting Two– Storey Commercial building.

1. National Structural Code of the Philippines 2015, NSCP2015, Volume 1 – Generally for the
entire Analysis and Design Requirements
2. Uniform Building Code 1997 Edition, UBC97 – For Building Seismic Analysis

DESIGN PARAMETERS

STORIES (LEVELS)
Levels Storey Height (m)
Footing to GF 1.2
GF to 2F 5
2F - Roof 5

PROPERTIES
Beams Columns Slabs fc' fy
400mm X 21 Mpa
250 mm x 350 mm 400mm S100 230 Mpa

300 mm x 300
mm S150 (3000psi) (Grd33)
200 mm x 300 mm

LOADS
Dead Load
1) Selfweight
Concrete unit weight = 24 kN/m3
2) Member Load
100mm CHB 2.98 kN/m per meter height

Floor Load Floors Roof


115mm slab 2.76 - kN/m2
Roof framing - 0.41
Roofing sheet - 0.10
Waterproofing - - kN/m2
Floor finish 1.10 - kN/m2
Ceiling 0.10 0.10 kN/m2
MEP 0.10 0.10 kN/m2
4.16 0.71 kN/m2

Live Load
4.8 kN/m2 0.60 kN/m2

Seismic Parameters
UBC 97 / NSCP 2015
Zone = 4
Seismic Source Type = A
Importance Factor ( I ) = 1.0 (Standard Occupancy)
R = 8.5 - Special Moment Frame
Structure is located 17.1 km from seismic source
Ct = 0.0731

Wind Parameters
Wind (ASCE 7-10 / NSCP 2015)
Vwind = 250 kph
I=1.0
Exposure = B (typical structure in rural area)