PV System Summary

FearTheSkunk
18131 Metz Drive ++1.240.462.6554
Germantown, MD nsolpv@verizon.net
USA www.nsolpv.com

Site Summary Load / System Summary


Site Name: Valvula XV-1001 Design Load: 142.9 Ah Day @ 24.0 VDC
Location: ABANCAY, PERU Tilt: 20N Azimuth: 0E Tracking: Fixed
Latitude: 13.63S Longitude: 72.88W Elevation: 2398 m Min ALR: 1.40 Avg ALR: 1.58
Comments: U Lowell : PER5A, type H LOLP: 0.023 % Avail: 99.995 % Avg BSOC: 95 %

System Summary
PV (Module / Array) Battery (Unit / Total) Controller:
Model: Q.PEAK-L-G5 375 Model: OPzV12-200 Model: VT-65 (24 Vdc)
Rating: 375W/ 1.50kWp Rating: 14.40 Type: MPPT
Modules: 4 # Units: 6 Voltage: 24
Config: 2 S x 2 P Config: 2 S x 3 P Rating: 65
Vmpp: 39.80 / 79.6 Voltage: 12.0 / 24.0 Quantity 2
Impp: 9.42 / 18.8 Amp-hr: 200.0 / 600.0 Inverter:
Voc: 48.73 / 97.5 Rating: 3.4 days Model: n/a
Isc: 9.86 / 19.7 Voltage: n/a
Rating: n/a
Quantity n/a
System Performance Summary
Month Array Insol Avg Temp Array Sys Losses Load Batt Size Array/Load Avg BSOC LOLP
(kWh/m2/d) (deg(%)
C) (Ah/day) (%) (Ah/day) (days) Ratio (%) (%)
Jan 4.81 13.8 212.1 10 142.9 3.3 1.48 95 0.006
Feb 4.52 13.8 199.5 10 142.9 3.3 1.40 93 0.023
Mar 4.89 13.6 215.2 10 142.9 3.2 1.51 94 0.015
Apr 5.12 13.2 225.1 10 142.9 3.2 1.58 95 0.005
May 5.22 12.0 230.0 10 142.9 3.2 1.61 96 0.002
Jun 5.23 10.9 230.9 10 142.9 3.2 1.62 97 0.000
Jul 5.47 10.7 241.4 10 142.9 3.2 1.69 97 0.000
Aug 5.50 13.0 241.4 10 142.9 3.2 1.69 96 0.001
Sep 5.09 14.5 223.3 10 142.9 3.3 1.56 95 0.002
Oct 5.52 15.4 241.0 10 142.9 3.3 1.69 96 0.000
Nov 5.35 14.9 234.2 10 142.9 3.3 1.64 96 0.001
Dec 4.70 14.5 206.8 10 142.9 3.3 1.45 95 0.008

System Performance
ALR And Normalized Load

1.6
1.4
esignLoad

1.2
1
LROf D

0.8
0.6
A

0.4
0.2
0
Jan Feb Mar Apr May Jun Jul Aug Sep Oct Nov Dec
Mo n th

Norm alized System Load Array / Load Ratio

NSol! Technology Copyright 1993-2012 FearTheSkunk