V Assy.
Anodized Aluminum,
Mechanical Drive
Manual FPPMSV02, Rev. 2010-12
Installation,
Operation &
Parts Manual
Flow meter P/No.: TS_________________ Flow meter S/No.: __________________
The flow meter shipped under this general manual, has specifically:
PRESET COUNTER
STRAINER
PRESET VALVE
BACKPRESSURE
VALVE FLOW
(not visible) METER
1.2
TS Series, Principle of Operation
About FPP Meters In a full 360° rotation of the gears, four such known volumes
We thank you for purchasing an FPP Meter for liquid meas- are released to the downstream side of the flow meter.
urement service. FPP Meters, formerly Fluid Power Prod- With precision machining and close internal tolerances, the
ucts, is now a trade name of Tuthill Transfer Systems. FPP slippage is minimal for superior linearity (accuracy) over a
was established in 1980. Since its inception, the company broad turn-down ratio. Oval gear meters are largely unaf-
has been dedicated to manufacturing cost-effective, high fected by changes in liquid viscosity (see page 1.8).
performance flow metering devices for petroleum, industrial,
commercial and municipal service. The TS Series meter is designed to provide:
Our facilities include computerized order entry and inventory V●● Assy: Drive to a mechanical register (this manual).
control, so that you are assured of accurate and prompt de- E & F●● Assy: Electric pulse signal to an electronic
liveries. Furthermore, our production personnel ensure that register installed on the flow meter.
each order, regardless of size, receives individual attention.
S & W●● Assy: Electric pulse signal to a remote
Constant attention to new product development and produc- electronic register.
tion design, our high standards of manufacture and final
testing are the reasons why FPP Meters meet your most In the two electronic versions, the flow meter is 100% gland-
demanding requirements. With the ‘Waveform’ oval gear less with static O-ring seals only. A pulser (pulse pick-up)
(2003 patent) meter accuracy is better than ever before. detects the movement of internal magnets, to generate the
signal to the electronic register. Several types of pulse sig-
Our meters are used in batching, blending, process control nal are available to ensure signal compatibility with all elec-
and to dispense fluids in liquid handling facilities throughout tronic registers.
the World. Service includes gasohol blends, bio-diesel and
special formulation racing fuels.
Fluid Compatibility
FPP Meter flow meters are available in anodized aluminum
Principle of Operation and stainless steel, with a variety of rotor types, and seal &
Positive Displacement meters have a measuring chamber, bearing materials, to ensure compatibility with a broad range
where inlet & outlet are separated by rotors, a rotating ele- of liquids and operating conditions. If in doubt about com-
ment or sliding vanes. As the liquid passes through the flow patibility with a specific fluid or the operating conditions,
meter, it causes the rotors/element/vanes to turn, which please refer to FPP210 (Liquid Compatibitily list) or
forms the basis for volumetric measurement. FPP200 (FPP Technical Manual). If those publication do
The Oval Gear metering principle is based on two elliptical not provide a clear answer, please consult with your author-
(oval) gears, which turn on center on two horizontal shafts ized FPP Meter distributor, or Customer Care at the factory.
inside a measuring chamber formed by two overlapping cyl- While most refined petroleum products can be handled with
inders. The oval gears have meshing teeth along their en- the same flow meter, some require different rotors and/or
tire circumference, ensuring that the gears will maintain cor- seals. Do not change service liquid, without consulting with
rect position in relation to each other at all times, without the your authorized FPP Meter distributor.
use of timing gears.
The volume being transferred from the Model Nominal Capacity Normal turn-down is 10:1.
inlet to the outlet side (= volume meas- TS10A 40 GPM 150 lpm Operation in excess of nominal
ured), forms between the oval gear capacity will cause excessive
TS15A 60 GPM 230 lpm wear or premature failure.
and the side of the measuring cham- TS20A 150 GPM 570 lpm Meters can be calibrated for
ber, alternately in the upper and the
TS30A 200 GPM 760 lpm use below 10%, if the flow rate
lower half of the measuring chamber. is steady or viscosity > 50 cSt.
1.3
TS Series, Anodized Aluminum - Specifications for V●● assemblies
Flow Meter nominal capacity:
Materials ● Normal operating range is w ith 10:1 turn-dow n from model
Case : Anodized aluminum nominal capacity.
Rotors : PPS with carbon bearings, ● On low viscosity liquids, best performance (linearity/service life)
See cover for
(oval gears) TeflonTM bearings optional. rotor & seal is betw een 50% and 85% of model nominal capacity.
Posts : HC303SS materials in ● On diesel fuel, TS20A & TS30A models w ith m echanical
Seals : VitonTM standard, this meter. register only may be operated to 125% of nominal capacity in
TeflonTM optional.
intermittent service (this does NOT apply to models with
preset and/or printer).
Connections Intermittent service = < 6 hours/day,
Bolted companion flanges with NPT or BSP port;
and deliveries not to exceed 15-20 minutes.
Optional: Anodized aluminum welding flanges ● On higher viscosity liquids, model nominal capacity is
Carbon steel welding flanges
reduced as per tables below .
Carbon steel 150# RF ANSI adaptors
Flow Meter Coefficient
Pressure Rating at 100°F (38°C) with 3:1 Safety Factor Carbon brgs. Teflon brgs. Rotor
Meter/Strainer : 150 PSI/100°F = 10.3 BAR/40°C Liquid Viscosity
Air Elim/Valves: 150 PSI/100°F = 10.3 BAR/40°C B L I C M J Code
SSU cSt LV HT HV LV HT HV TYPE
Temperature Rating 32 1 1.00 1.00 1.00 1.00 1.00 1.00
V assy : -40°F to +180°F = -40°C to +80°C 60 10 1.00 1.00 1.00 1.00 1.00 1.00
Use HT or HV rotors if temp. can exceed 120°F = 50°F 240 50 1.00 1.00 1.00 1.00 1.00 1.00
465 100 1.00 1.00 1.00 1.00 1.00 1.00
925 200 1.00 1.00 1.00 0.90 0.90 1.00
Meter Performance
1,415 300 0.86 0.86 1.00 0.73 0.73 0.98
When field calibrated on actual liquid of service
1,890 400 0.77 0.77 1.00 0.62 0.62 0.96
Linearity
2,360 500 0.71 0.71 1.00 0.57 0.57 0.94
Over 5:1 turn-down from max. capacity : ±0.175%
2,830 600 0.66 0.66 1.00 0.53 0.53 0.92
Over 10:1 turn-down from max. capacity : ±0.30%
3,300 700 0.63 0.63 1.00 0.50 0.50 0.90
Over 30:1 turn-down from max. capacity : ±0.5%
3,775 800 0.60 0.60 1.00 0.48 0.48 0.85
Repeatability 4,250 900 0.56 0.56 1.00 0.45 0.45 0.80
0.05% or better under constant conditions 4,720 1,000 0.54 0.54 1.00 0.43 0.43 0.75
9,440 2,000 0.35 0.77 0.28 0.65
Nominal Capacity 14,150 3,000 0.28 0.65 0.22 0.55
With LV rotors on 1-300 cP viscosity: 18,875 4,000 0.24 0.58 0.19 0.46
23,600 5,000 0.19 0.53 0.15 0.42
With HV rotors on 5-1000 cP viscosity:
28,325 6,000 0.16 0.49 0.13 0.39
GPM LPM m3/h
33,050 7,000 0.14 0.47 0.11 0.37
TS10A 40 150 9
37,750 8,000 0.12 0.44 0.09 0.35
TS15A 60 230 14
42,475 9,000 0.10 0.42 0.08 0.34
TS20A** 150 570 34
47,200 10,000 0.41 0.32
TS30A** 200 760 45
94,400 20,000 0.30 0.24
** = On low viscosity lubricating liquids, intermittent 141,600 30,000 0.24 0.19
use to 125% of capacity is permitted. 188,800 40,000 0.20 0.16
236,000 50,000 0.18 0.14
Viscosity 283,200 60,000 0.17 0.13
With LV rotors 100% capacity to 1,500 SSU/300 cP. 330,400 70,000 0.14 0.11
With HV rotors 100% capacity to 5,000 SSU/1,000 cP. 377,600 80,000 0.13 0.10
With HV rotors, the flow meter may be used to 424,800 90,000 0.12 0.10
1,500,000 SSU/350,000 cP at reduced flow rates (see 472,000 100,000 0.11 0.09
meter viscosity/coefficient table in next column). 944,000 200,000 0.08 0.06
1,416,000 300,000 0.07 0.05
1,888,000 400,000 0.06 0.05
Opt. Pulsers on mechanical register
2,360,000 500,000 0.06 0.04
10:1 pulser 100:1 pulser
2,832,000 600,000 0.06 0.04
1/10 gallon register 10 PPG 100 PPG
3,304,000 700,000 0.05 0.04
Whole gallon register 1 PPG 10 PPG
3,776,000 800,000 0.05 0.04
1/10 liter register 10 ppl 100 ppl
Whole liter register 1 ppl 10 ppl 4,248,000 900,000 0.05 0.04
4,720,000 1,000,000 0.05 0.04
Dekaliter register 0.1 ppl 1 ppl
1.4
This page is intentionally left blank
1.5
Flow Meter Part No.
Flow Meter Part No.
Most flow meter assemblies can be fully defined with a 10 position Part Number. Only when non-standard options are se-
lected (pulser, seals, non-standard rotors or strainer basket), does it become necessary to extend the Part No.:
Position 1-5 = Model No. Capacity & Materials
Position 6-8 = Assy. No. Register & Accessories, refer to table on page 1.7.
Position 9-17 = Variables See codes below.
TS Series
MECHANICAL, 2010 P/No. overview
R
S
e
NE
S
siz
GE
R.
R
R
SE
LS
LIB
AI
TO
AN
sh
A
R
L
RO
CA
Me
PU
SE
FL
ST
MODEL No. ASSY No.
If all STA NDA RD selectio ns, these identifiers are no t filled in.
T S 2 0 A V _ _ C M
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18
See Assy
A Anodized Aluminum Chart
Flanges
A NPT companion flanges Pulser on Register
B BSP companion flanges X none (standard)
C 150# RF ANSI adaptors, CS D 10:1 dry reed
F AA welding flanges S 100:1 solid state
H CS welding flanges
Seal Material
Calibration for mechanical register A Viton,
T 1/10 gallon, not on TS30 B Teflon,
G Whole gallon, not on TS10 or TS15
Y 1/10 liter, TS10 only Strainer TYPE
L Whole liter, not on TS10 S Std. Strainer (blank if 40 mesh)
D Dekaliter, not on TS10 or TS15 H Hi Cap strainer
U 1/10 Imp gallon, not on TS30
I Whole Imp gallon, not on TS10 or TS15 Strainer BASKET
4 40 mesh, std/LV & HT rotors
Rotor/Bearing materials & Rotor type 2 20 mesh, std/HV rotors
B PPS/carbon, LV Standard = 'GREEN' price in price lists. 8 80 mesh, optional (3" only)
L PPS/carbon, HT Std for HT service ('YELLOW' in p/l) 0 100 mesh, optional (2" only)
I PPS/carbon, HV Std for HV service ('BLUE' in p/l)
C PPS/Teflon, LV
M PPS/Teflon, HT
J PPS/Teflon, HV Area Shaded YELLOW = non-std => Longer Lead Time!
1.6
Flow Meter Assy No. = Register & Accessory combination
Without
register, but no ratio gear plate or
V23
register
register (distributor to add) ACV
V28 BPV
V04 V05 V06
With Calibrator, RAD Adaptor, Ratio
VR1
7887
Gear Plate & Register
V25 ACV
V29 BPV
V07 V08 V09
VR2
V26 ACV
V31 BPV
V35 V36 V37
Same + Preset Counter/Micro Switch
VR3
V32 BPV
V39 V40 V41
Same + Zero Start Ticket Printer, Preset
VR4
7887, 7888,
Counter/Micro Switch assy
V42
7889 & 7856
ACV
V44 BPV
V51 V52 V53
Same + 7887, 7889 &
V54
Micro Switch kit on preset counter 7856
ACV
V46 BPV
V55 V56 V57
Same + 7887, 7888,
V58
Micro Switch kit on preset counter 7889 & 7856
ACV
1.7
Installation, Start-Up & Operation
BPV
OPT ION A L B Y - PA SS LI N E
Normal Operation : BPV, CV1 & CV2 closed
Service/Maintenance: IV1 & IV2 closed (by-pass open)
TRV During Calibration : IV2 & BPV closed, other valves open
IV1 IV2
OPERATING FLOW METER CV1 CV2
1.9
Changing Direction of Flow
TS Series flow meters can operate in either direction. Stan-
dard assembly, when facing the flow meter, has the flow
going Left-to-Right, unless specified differently at time of 14
the order. A label with the word INLET is placed on the inlet
flange, as assembled at the factory.
When the meter is first installed, check that the register is 19
21A
turning correctly when you start the flow. If it is not (or it is
attempting to run backwards), check position of the face
gear (11E) on the calibrator drive shaft (21A), and if neces- 11D
sary correct the position of the face gear versus the packing
gland pinion (11D) as explained below.
INLET 11E
Left-to-Right flow = Face gear below packing gland pinion
Right-to-Left flow = Face gear above packing gland pinion
The direction of flow can be changed in the field. This re-
quires the following steps:
Any accessories (strainer and/or preset valve) attached to
the flow meter must be moved to the opposite side. 21E
First remove screws (16 & 17) to detach the dust cover
(15) from the RAD (14 = Right Angle Drive) adaptor.
Now refer to photo in next column.
11E
Notice position of the face gear (11E) on the calibrator
drive shaft (21A) in relation to the packing gland pinion 21F
(11D). 21B
21E
Remove E-ring (21F) with a screwdriver or small pliers.
21C
As shown, the E-ring is installed below the face gear,
where it is not visible in the photo. 21D
1 . 10
Calibration, Mechanical Flow Meters
W&M Certifications: Mechanical TS Series meters have a mechanical drive train
directly from the rotors (oval gears) to the register. To con-
TS10A US vert rotor movement to volume reading on the register, this
TS15A US & Canada drive train includes 3 calibration components:
TS20A US, Canada, EU & Australia
TS30A US, Canada, EU & Australia Packing gland pinion (11D)
can have 12 or 24 teeth,
Certifications are liquid specific. Please refer to national while the face gear (11E)
certificates for liquid categories covered. always has 24 teeth, re-
sulting in a 1:1 or 2:1 ratio.
The appropriate ratio de-
19
Flow Meter Calibration at the Factory pends upon flow meter
All TS Series meters are accuracy tested prior to shipment. model size & specific unit
Data from accuracy testing is not supplied with flow meters, of calibration selected for
since results achieved on our test fluid do not apply to actual the register.
liquid of operation, unless the two liquids have identical vis-
Mechanical calibrator (19). 11D
cosity characteristics.
This component makes
When calibrated on a liquid with 1 cP viscosity, if the flow minute adjustments to final
meter is not field recalibrated on actual liquid of service, we calibration to compensate 11E
expect that the flow meter will be: for individual flow meter
characteristics, viscosity of
Under by 1-2% on a liquid with 0.5 cP viscosity. fluid being metered, and
Over by 0.35% to 0.6% on a liquid with 10 cP viscosity. flow meter wear factor.
Over by 0.7% to 1.2% on a liquid with 100 cP viscosity. A ratio gear plate installed below the mechanical register.
The accuracy curve will not shift significantly at higher vis- Gearing on this gear plate is specific to flow meter model
cosities, even if the actual operating liquid has viscosities up & unit of calibration selected. Optimum ratio is between
to 500,000 cP. 0.5000 & 5.0000 for best service life.
Accuracy curves of individual flow meters vary slightly. The mechanical register is common to all flow meter mod-
Such minor variations are corrected in the mechanical cali- els, so it is possible to move registers from one flow me-
brator. In our calibration procedure, the meter calibrator is ter to another. Do NOT move the ratio gear plate from
set for zero error, when operating at 95-100% of capacity on one flow meter to another.
1 cSt viscosity fluid.
.Frequency of Re-Calibration
In installations subject to local Weights&Measures regula-
tions, frequency of recalibration must conform to such
Flow Meter Calibration in The Field regulations.
Since we cannot test on actual fluid of operation, it is the
responsibility of the buyer to field calibrate: If local authorities issue regulations for non-W&M flow
In place of service meters, such regulations must be observed.
On actual operating liquid. If user is ISO9000 certified, user ISO standards will indi-
cate frequency of re-calibration for instrumentation.
This will minimize errors arising from:
Those standards should be observed.
A. Operation at a different flow rate.
When no regulations or standards apply, our recommenda-
B. Operation on a fluid with different viscosity
tions are:
It is recommended that written records be maintained on all
A. Calibrate immediately after installation.
flow meters. These records should include:
B. Re-calibrate after 15-30 days.
Supplier and Service Department phone number.
Date of installation. C. Re-calibrate after 180 days and again after 360 days.
Details of maintenance performed. After the run-in calibration (B) and follow-up calibrations (C),
Date & result of each re-calibration, with % change made it is possible to evaluate degree of change under normal
on flow meter calibrator assy. operating conditions. Based on values found, and total vol-
ume being metered under normal operating conditions, de-
cide whether a 6, 12 or possibly 24 month schedule should
be adopted.
1 . 11
Flow Meter Calibration
Procedures & Methods When prover/master meter reading is less than flow
Flow meters used in systems where the flow rate can fluctu- meter register reading, add percentage calculated
ate, should be tested at minimum, intermediate & maximum by turning the calibrator in the + volume direction.
flow rates. In non-W&M service, a flow meter always oper-
ating at a steady flow rate, can be tested at that flow only. When prover/master meter reading is more than flow
meter register reading, subtract percentage calcu-
All tests should be repeated 3 times to confirm repeatability. lated by turning the calibrator in the - volume direction.
All tests should be of at least 60 second duration, to mini-
mize the effect of flow meter error during start-up and shut- After correcting calibrator setting, circulate product
down. through the flow meter for a few minutes. Then perform
at least 3 more tests, to confirm flow meter accuracy &
After calibrating a known volume (X) into an accurate repeatability.
prover, through a master meter, or against a certified
scale with adequate resolution, compare with register If the flow meter does not repeat, it will likely require a
reading (Y) and calculate correction: new set of rotors (oval gears).
17
14
This provides access to the calibrator assembly (19), If there is a sudden significant jump in correction required,
which has a dial on the front, and is marked with direc- the rotors are likely about worn out. Rotor replacement
tions for + and - Volume. Each graduation of this dial should be considered now, rather than letting further wear
represents approx. 0.06% change cause rotors to start rubbing on flow meter housing.
1 . 12
Servicing the Flow Meter
Always coat bolt threads with an anti-seize, or an appropri-
! SAFETY INSTRUCTIONS ! ate lubricant to prevent thread damage, and to assure
proper torque values are applied when reassembling.
REMOVE ALL INTERNAL PRESSURE
If flow meter threads are damaged, repair using inserts.
BEFORE OPENING THE FLOW METER.
DRAIN & RINSE THE FLOW METER Servicing the Mechanical Drive Components
Flow meter wear depends upon several variable factors
BEFORE SERVICING. (flow rate vs model capacity, lubricity of the liquid, total vol-
IF IT IS NECESSARY TO TRANSPORT OR ume being metered annually and maintenance of mechani-
cal register, preset and/or printer), so it is impossible to pre-
SHIP THE FLOW METER TO A DIFFERENT dict the expected life for each component.
LOCATION FOR SERVICE, IT MUST BE
There are 8 parts or components, which will require inspec-
RINSED 3 TIMES WITH A NEUTRAL FLUID tion and/or replacement at some point. In the order they are
PRIOR TO TRANSPORTATION/SHIPMENT. likely to occur, these are:
Regular Maintenance (1-3 years)
Installation, Maintenance & Service must be performed A. Face Gear (11E) & Packing Gland Pinion (11D)
by personnel:
B. Packing Gland O-ring (11B)
A. Qualified to work on this type of equipment. Longer Term Wearing Components (2-5 years)
B. Familiar with all applicable local codes and ordi- C. Calibrator Drive Shaft Assembly (21)
nances covering the type of service, where the flow D. Gear Plate, internal (4)
meter is used (gasoline, LPG, etc.). Very Long Term Wearing Components (3-10 years)
Avoid pipe strain and stress when making flow meter re- E. Packing Gland (11)
pairs. The weight of piping and the flow meter should be F. Oval Gears (2), or inspection of measuring chamber
supported independently. This means that the meter can be Longest Term Wearing Components (5-20 years)
serviced without affecting piping alignment. G. Post Plate assembly (3)
Avoid prying or exerting heavy pressure on precision parts, H. Calibrator Assembly (19)
as this could affect the performance of the flow meter. Of these, only A, C & H can be performed without taking the
Assure that all machined parts are free of burrs and nicks. pressure off the system and draining the flow meter. The
Stone all machined surfaces if necessary to remove burrs. remaining all require opening of flow meter interior.
The first step is to remove the dust cover (see pages 1.8-9)
from the RAD (14 = Right Angle Drive adaptor).
14a
A. Face Gear (11E) & Packing Gland Pinion (11D)
C. Calibrator Drive Shaft Assembly (21)
26 Always replace Face Gear & Packing Gland Pinion together.
They can be ordered under a single P/No. (see page …).
Remove E-ring (21F) from the drive shaft assembly (21)
12 14b with a screwdriver or small pliers.
11C/D
Replace Face Gear (11E) on the calibrator drive shaft
assembly.
11E Remove E-ring (11C) from the packing gland (11) with a
screwdriver or small pliers, and replace the Packing
Gland Pinion (11D).
21F Reassemble in reverse order.
18
1 . 13
Servicing the Flow Meter
B. Packing Gland O-ring (11B) 6
E. Packing Gland Assembly (11)
You now have access
First relieve system pressure and drain the flow meter.
to the Gear Plate as-
Then follow instructions for above for removal of calibrator 4
sembly (4). If rebuild-
drive shaft assembly. Remove E-ring (11C) from the pack-
ing with repair kit, no
ing gland assembly, and pull off the pinion (11D).
further disassembly is 8
Remove three screws (13) from the packing gland re- required.
tainer (12). Remove the retainer If replacing the oval
5
Packing Gland O-ring and/or Packing Gland assembly gears, inspecting the
can now be replaced. measuring chamber or
replacing the complete 7
When replacing the Packing Gland, the drive dog must be gear plate:
aligned with the slot in the gear on the gear plate.
Remove 4 screws (6) from the gear plate. The gear plate
Reassemble in reverse order. can now be pulled off dowel pins (5), using a 5/16-8 x 1”
D. Gear Plate, Internal (4) jack bolt if necessary.
F. Oval Gears (2), or inspection of measuring chamber The gear plate assembly can now be rebuilt or replaced
The wearing parts in the Gear Plate assembly are the reduc- as required.
tion gears. On a longer time scale, the bushing in the gear
plate will wear out. The gear plate assembly can be rebuilt Prior to removing the rotors (oval gears), use a soft pencil
or replaced in one of 3 ways, with d.3 being what is most to make an alignment mark where the gears engage.
commonly required: This will make re-assembly easier.
d.1 Complete gear plate assembly The oval gears can now be inspected or replaced as re-
quired. When placing the oval gears back on the posts,
d.2 Gear plate/bushing assembly only, re-using gears. make sure that they are aligned and spin freely on the
d.3 Repair kit, with reduction gears & fasteners. posts. If they are not aligned correctly, they will disen-
gage.
First relieve system pressure and drain the flow meter.
Also, detach the mechanical register stack, to take the
The measuring chamber can now be inspected. Remove
any deposits using a fine emery cloth or wire brush. Be
weight off of flow meter front cover.
careful to remove any particulate material, which can
If the mechanical register stack includes a preset counter, cause the meter to jam.
detach the linkage from the trip ring (see top of next column)
A minor scratch in chamber surface can be carefully
prior to taking the register stack off.
smoothed out, but be careful not to cause scoring or to
STUD
change the dimensions. If the measuring chamber shows
signs of scoring from rotors rubbing, it should be re-
placed.
Re-assemble in reverse order.
G. Post Plate assembly (3)
First relieve system pressure and drain the flow meter.
SLEEVE
Remove the cover
Valve linkage connects to bolts (10) from the
preset trip ring at the rear.
6 5
rear cover (9), now
Slide the sleeve towards remove the rear 3
Register stack attaches to the RAD the shaft to release the cover from the flow
with 4 screws, 2 front and 2 rear. mounting stud. meter and inspect the
cover O-ring (7) for
Remove dust cover & calibrator drive shaft as explained flaws. Teflon fitted
above. meters: Always re- 9
place seals when
Remove 4 screws/washers (27/28) holding the RAD to
opening the flow me-
the front cover (8).
ter.
Remove the cover bolts (10) from the front cover (8), now
remove the front cover from the flow meter and inspect 7 10
the cover O-ring (7) for flaws. Teflon fitted meters: Al-
ways replace seals when opening the flow meter.
1 . 14
Servicing the Flow Meter
Remove 4 screws (6) from the post plate (3). The post For optional flow meter accessories:
plate assembly can now be pulled off dowel pins (5), us- Strainer
ing a 5/16-8 x 1” jack bolt if necessary.
Air Eliminator
The posts are expected to last through several sets of Pls see Section 2
rotors. When the posts show signs of wear, or if they Backpressure Valve
have been bent due to hydraulic shock, the complete Air Check Valve
postplate assembly must be replaced.
If hydraulic shock is suspected, the cause should be
identified and eliminated. For optional control valves:
Mechanical Preset Valve
If the posts show uneven wear (bearings cutting
1-Stg solenoid operated Valve Pls see separate
grooves into the post), the differential pressure across
Tuthill manual
the flow meter is too high, due to a combination of ex- 2-Stg solenoid operated Valve
cessive flow rate & viscosity. Solutions are:
1. Reduce the flow rate.
For mechanical register stack:
2. Increase the temperature to reduce the viscosity.
Register
3. Use a larger flow meter.
10:1 pulser
Re-assemble in reverse order.
100:1 pulser Pls see separate
H. Calibrator Assembly (19) Veeder-Root
The calibrator assembly is a mechanical device, which will Preset Counter
manuals
wear out eventually. Calibrator wear can be accelerated by Micro Switch kit
failure to clean and lubricate the components in the me-
chanical register stack (refer to separate manuals). If flow Ticket Printer
meter re-calibration gives erratic results (non-repeating), it is
likely that the calibrator is worn out.
To replace the calibrator:
Remove dust cover, drive shaft assembly and register
stack, as explained under A and D.
Remove 2 screws (20) holding the Calibrator Assembly to
the Veeder-Root register flange (14B), using a Phillips
screwdriver.
Re-assemble in reverse order.
1 . 15
Flange Kits & Parts for Flanges
Tuthill TS Series flow meters come standard with bolted new flange is required when adding to or deleting accesso-
companion flanges, with either NPT or BSP threaded ports. ries from an existing flow meter. When adding accessories
Other options are welding flanges (aluminum or steel), and to TS10A & TS15A models, an adaptor might be required.
150# RF ANSI adaptors (steel). Single flange kits & adaptors, and relevant seals & screws,
Since meter (square) & accessory (round) flanges differ, a are identified below.
Flow Meter Strainer Standard High Cap. Air Check & Electronic
Inlet/Outlet or Valve Strainer Strainer Preset Vlv Preset Valve
Flange Adaptor Inlet Flange Inlet Flange Outlet Flg Outlet Flange
TS10A, OS NPT/Viton FK1100-1 FK1209 FK1104-1 na na FK1106-S1
1” BSP/Viton FK1101-1 same FK1105-1 na na FK1107-S1
ANSI/Viton FK5100-1 same FK5104-1 na na FK5106-S1
Viton O-ring SL1122 SL1122 SL1334 na na SL7500
NPT/Teflon FK2100-1 FK1209-T FK2104-1 na na na
BSP/Teflon FK2101-1 same FK2105-1 na na na
ANSI/Teflon FK5101-1 same FK5105-1 na na na
Teflon O-ring SL2122 SL2122 SL2334 na na na
Flange screw FS2950 FS0920 FS2960 na na 1123413
TS10A, NS NPT/Viton FK1110-1 na na na na na
1” BSP/Viton FK1111-1 na na na na na
Viton O-ring SL1223
NPT/Teflon FK2110-1 na na na na na
BSP/Teflon FK2111-1 na na na na na
Teflon O-ring SL2223
Flange screw FS2950
TS15A NPT/Viton FK1160-1 FK1215² FK1154-1 na FK1156-1 FK1156-S1
1½” BSP/Viton FK1161-1 same FK1155-1 na FK1157-1 FK1157-S1
ANSI/Viton FK5160-1 same FK5154-1 na FK5156-1 FK5156-S1
Viton O-ring SL1233 SL1233 SL1334 na SL7500 SL7500
NPT/Teflon FK2160-1 FK1215-T² FK2154-1 na FK2156-1 na
BSP/Teflon FK2161-1 same FK2155-1 na FK2157-1 na
ANSI/Teflon FK5161-1 same FK5155-1 na FK5157-1 na
Teflon O-ring SL2233 SL2233 SL2334 na SL2500 na
Flange screw/stud FS9902 FS5201 FS2960 na FS2960 1123413
Flange washer FS5008 FS5203 na
Flange nut na FS5202 na
TS20A NPT/Viton FK1200-1 na FK1204-1 FK1204HC-1 FK1106-1 FK1106-S1
2” BSP/Viton FK1201-1 na FK1205-1 FK1205HC-1 FK1107-1 FK1107-S1
ANSI/Viton FK5200-1 na FK5204-1 FK5204HC-1 FK5106-1 FK5106-S1
Viton O-ring SL1233 na SL1334 SL1350 SL7500 SL7500
NPT/Teflon FK2200-1 na FK2204-1 FK2204HC-1 FK2106-1 na
BSP/Teflon FK2201-1 na FK2205-1 FK2205HC-1 FK2107-1 na
ANSI/Teflon FK5201-1 na FK5205-1 FK5205HC-1 FK5107-1 na
Teflon O-ring SL2233 na SL2334 SL2350 SL2500 na
Flange screw FS2950 na FS2960 FS2965 FS2960 1123413
TS30A NPT/Viton FK1300-1 na FK1304-1 FK1304-1 FK1106-1 FK1106-S1
3” BSP/Viton FK1301-1 na FK1305-1 FK1305-1 FK1107-1 FK1107-S1
ANSI/Viton FK5300-1 na FK5304-1 FK5304-1 FK5106-1 FK5106-S1
Viton O-ring SL1240 na SL1350 SL1350 SL7501 SL7501
NPT/Teflon FK2300-1 na FK2304-1 FK2304-1 FK2106-1 na
BSP/Teflon FK2301-1 na FK2305-1 FK2305-1 FK2107-1 na
ANSI/Teflon FK5301-1 na FK5305-1 FK5305-1 FK5107-1 na
Teflon O-ring SL2240 na SL2350 SL2350 SL2503 na
Flange screw FS1951 na FS2965 FS2965 FS2965 FS5210
NOTES: 1= Used for both strainer & air check valve when assembled to TS10A model.
2= Used for strainer only when assembled to TS15A model (valves fit directly to meter body).
1 . 16
Troubleshooting the Flow Meter
Prior to opening or disassembly of any flow meter, all Product Flows, register does not record correctly
internal pressure must be relieved and all liquid must be If the error factor is constant, the flow meter is fine. The
drained. This must be done in accordance with applica- likely cause is either:
ble company and local codes & ordinances. Incorrect K Factor in the electronic register. Re-calibrate
Make sure that all necessary safety precautions have the meter and correct the K Factor.
been taken, including proper clothing, personal safety A constant problem with air getting into the system. Re-
equipment and fire safety equipment if required. view system design and control valves.
If the error is random, the likely cause is either:
No Flow Poor cable connections (insulation not trimmed, or stray
strands getting close to incorrect contacts). This can be
Blocked strainer basket. Clean the basket.
either on the scaler board or where pulse signal is con-
Faulty or non-functioning pump. Repair pump. nected to the register. Inspect and correct connections
Valve stuck in closed position. Check and repair valves. as necessary.
Flow meter ‘frozen’ due to build-up of chemical salts (or Valve leaking, allowing a portion of the system to drain.
frozen water) inside the measuring chamber. Clean the Check & repair valves.
flow meter (see D & F on page 1.12), and inspect for An intermittent problem with air in the system, combined
damage. with inadequate air elimination. Review system design
Meter jammed on a particle, that has passed through a and control valves.
damaged strainer basket. Remove particle (see D & F on Interference from other electrical equipment nearby., pos-
page 1.12) and replace rotors if necessary. Replace sibly combined with sub-standard cables.
strainer basket, see page 2.1).
Broken Rotors (Oval Gears = #2)
Reduced Flow Rate System started on air/vapors.
Strainer basket partially blocked. Clean the basket (see Replace rotors and inspect meter case (#1) for damage;
page 2.1). repair/replace as necessary. Slowly fill the system with
Pump not functioning correctly. Repair pump. liquid before starting the pump. Gradually increase flow
Valve stuck in partially closed position. Check valves and rate to full capacity.
repair. Rotors jammed on a foreign particle (welding slag, part
Meter rotors (oval gears) partially ‘salted’ with chemical broken off other equipment, etc.).
deposits, slowing the movement. Clean the meter (see D Replace rotors and inspect meter case (#1) for damage;
& F on page 1.12). repair/replace as necessary. Add a strainer in front of the
flow meter. Slowly fill the system with liquid before start-
Product Flows, but the register does not record ing the pump. Gradually increase flow rate to full capac-
Check packing gland pinion (11D) & face gear (11E). ity.
If disengaged, re-assemble the drive shaft assembly
correctly.
Breaking Teeth on Rotors (Oval Gears = #2)
Breaking Teeth/shaft on Reduction Gears (#4D/F/G
If worn, replace pinion & face gear as a set.
These are signs of hydraulic shock conditions in the sys-
If the calibrator drive shaft turns, the problem is either in tem. Common sources:
the calibrator assembly (19) or in the mechanical register.
Starting or stopping flow too rapidly. Replace damaged
Remove the calibrator assembly (see H on page 1.13). components and correct operational practices.
Insert the drive shat and turn by hand. If it turns
Pump by-pass not adjusted properly. Re-adjust as nec-
smoothly without binding, the problem is in the register.
essary.
Refer to Veeder-Root register manual & parts list.
If the calibrator drive shaft does not turn, the problem is Open connection to another portion of the system with
either in the packing gland or in reduction gears on the higher flow rates. Close connection prior to use.
bearing plate.
Check the connections between the pulser and the elec- Leakage from End Covers
tronic register. The seals (and possibly end covers) have been damaged
due to excessive pressure. There are two possible sources:
Check pulser output. Replace pulser (or SCL) if needed.
If product is flowing, and the flow meter is generating a
Starting or stopping flow too rapidly. Replace damaged
components and correct operational practices.
pulse signal, the problem is in the electronic register.
Please refer to the manual for the electronic register. The flow meter is in a system, where it can be isolated
between two valves. Add a Thermal Relief Valve to bleed
off excess pressure when the temperature rises.
1 . 17
Parts List
1 . 18
TS Series - Exploded View, Mechanical (V●● Assy.)
10
9
17
7
3
16
3A
5
15
1
14b
20
30
26
19 7
8 4
5
6
22
23
14a
11E 24
28
18 27
29
11B
10
11
13 12 25
21 C
B A
1 . 19
Tools & Torque Chart
Note: All torque specification are Reference guide listed from the Fastenal Technical Guide.
Warranty
Tuthill Transfer Systems (“Manufacturer”) warrants to each CLAIM FOR DAMAGES ARISING OUT OF THE
buyer of its FPP Meters products (the “Buyer”) for a period of MANUFACTURE SALE, DELIVERY OR USE OF THE
12 months from date of invoice or sales receipt, but in no event GOODS EXCEED THE PURCHASE PRICE OF THE GOODS.
more than 18 months from date of manufacture, that goods of The foregoing warranties will not extend to Goods subjected to
its manufacture (“Goods”) will be free from defects of material misuse, neglect, accident or improper installation or
and workmanship. Manufacturers sole obligation under the maintenance, or which have been altered or repaired by
foregoing warranties will be limited to either, at Manufacturer’s anyone other than Manufacturer or its authorized
option, replacing or repairing defective Goods (subject to representative. THE FOREGOING WARRANTIES ARE
limitations hereinafter provided) or refunding the purchase EXCLUSIVE AND IN LIEU OF ALL OTHER WARRANTIES OF
price for such Goods theretofore paid by the Buyer, and MERCHANTABILITY, FITNESS FOR PURPOSE OF ANY
Buyer’s exclusive remedy for breach of any such warranties OTHER TYPE, WHETHER EXPRESS OR IMPLIED. No
will be enforcement of such obligations of Manufacturer. If person may vary the foregoing warranties and remedies
Manufacturer so requests the return of the Goods, the Goods except in writing signed by a duly authorized officer of
will be redelivered to Manufacturer in accordance with Manufacturer. Warranties or remedies that differ from the
Manufacturer’s instructions F.O.B. Factory. The remedies foregoing shall not otherwise be binding on Manufacturer. The
contained herein shall constitute the sole recourse of the Buyer’s acceptance of delivery of the Goods constitutes
Buyer against Manufacturer for breach of warranty. IN NO acceptance of the foregoing warranties and remedies, and all
EVENT SHALL MANUFACTURER’S LIABILITY ON ANY conditions and limitations thereof.
Tuthill Transfer Systems (TTS) warranty does not extend to damage due to corrosion, salt deposits or
separation of chemicals - whether occurring during periods of operation or storage.
Components added after shipment from TTS, such as hose, nozzles & similar, are the responsibility of
the distributor or contractor selling the installation.
1 . 20
Strainer
Installation, Maintenance & Service must be performed • Check the strainer daily during the first week, or until no
by personnel: more debris is found in the basket.
A. Qualified to work on this type of equipment. • After the system has been thoroughly flushed, the strainer
B. Familiar with all applicable local codes and ordi- should be checked at least quarterly. The recommended
nances covering the type of service, where the flow frequency depends upon total volume, cleanliness of the
meter is used (gasoline, LPG, etc.). product and specific operating conditions.
• The primary purpose of the strainer, is to protect the flow Decreasing Flow Rate/No Flow
meter against jamming on foreign particles, such as weld- • Check strainer basket, it may be partially or fully clogged
ing slag, pipe scale or parts breaking off upstream equip- by sediment, particles or chunks of dried out product.
ment. • Check pump & upstream valves if the basket is clean.
The FPP strainer is strictly an insurance policy. For • Leaks around strainer basket cover
cleaning of contaminated fluids, larger straining or filtra- • Worn O-ring seal. Replace. Replace Teflon O-rings
tion equipment is required. every time the basket is cleaned.
• The secondary purpose of the strainer, is to provide a • Damaged O-ring seal due to hydraulic shock in the sys-
convenient location for the air eliminator required in many tem. Replace and eliminate source of hydraulic shock
systems. When no air eliminator is required, a blind conditions.
cover is used on the strainer.
Meter locking up (oval gears do not turn)
Functionality • Inspect the strainer basket for possible particle penetra-
The liquid enters the from the front (or rear), through the tion. Screen may have ruptured; this is commonly
center of the basket. The liquid flows through the fine mesh caused by failure to flush system adequately prior to start-
screen, and turns 90 to enter the flow meter. Baskets are up, or be a part breaking off other equipment. Replace
available with: the strainer basket.
20 mesh For high viscosity fluids (lube oil, etc.) • If caused by powdery particles settling out of suspension
40 mesh Diesel fuel, general purpose. during idel periods, the system may need to run 24 hours
100 mesh For gasoline/solvents. per day (circulating back to storage when not metering
200 mesh For LPG service. out).
Assembly • If rotors jammed on a particle:
The strainer can be assembled with the inlet from the front • Inspect meter case for damage. Minor scratches can be
(standard) or the back (optional). Bolt pattern of the inlet smoothed with a fine grit sand paper. Major scratches
flange and the basket cover are identical, so inlet position may require replacement of meter case.
can easily be reversed in the field.
• Inspect oval gears for damage. Replace if necessary.
Installation • Unidentifiable cause of flow meter calibration error
See page 1.4 for installation recommendations for the flow
meter (& strainer). When installing the flow meter, allow • Check strainer basket for particle penetration (ruptured
sufficient space at strainer inlet, so that basket cover can be mesh). If found, check meter case & rotors for damage.
removed, and the basket extracted for cleaning. Space re- • If no damage is found to the strainer basket, please con-
quired is: tact the FPP Meters distributor for assistance.
TS10A, TS15A & TS20A models: Min. 10” (250 mm)
TS30A model . . . . . . . . . . . . . . .: Min. 11” (275 mm)
Disassembly
1. Clean the basket cover plate, so no external particles will
Maintenance fall into the strainer after opening. Remove 4 screws (4)
Failure to follow Maintenance instructions may lead to from the basket cover plate (2).
damage to the strainer basket, and possible failure of 2. Remove basket cover plate (2) and the O-ring (3) from
the flow meter! the cover plate.
Prior to opening or disassembly of any accessory, all 3. Carefully pull the strainer basket (8) straight out. If any
internal pressure must be relieved and all liquid must be dirt falls back into the strainer, clean it up so that it does
drained. not migrate into the flow meter. Wipe the strainer clean
with a soft, lint free cloth.
This must be done in accordance with applicable com-
pany and local codes & ordinances.
2.1
Strainer
4. Clean the basket by flushing with a cleaning agent
compatible with the operating fluid. Use com- Inlet flange (5) and basket
pressed air, or a soft brush, to release particles cover (2) can be interchanged
from the screen.
Do NOT bang the basket against anything
hard. This will dent the basket, and may cause 9
problems with reinstallation and failure to seal.
11 3 2
5. Clean the inside of basket cover with a clean, lint 4
5 4
free cloth.
3
6. Remove the O-ring (3) from basket cover (2), and 10
inspect for wear or brittleness. Replace the O-ring
if necessary (always replace Teflon O-rings).
Re-Assembly
1. Replace the strainer basket (8) into strainer hous-
ing (1). 8
2. Inspect the O-ring and replace if necessary
6
(always replace Teflon seals). Insert the O-ring
(3) in the groove in the basket cover (2) 7
3. Attach basket cover (2) with 4 screws (4). Tighten
1
the screws evenly.
2.2
optional High Capacity Strainer for enhanced Air Elimination
2.3
Air Eliminator (Vapor Eliminator for LPG service)
Installation, Maintenance & Service must be performed Assembly
by personnel: With a square bolt pattern, the Air/Vapor Eliminator can be
A. Qualified to work on this type of equipment. indexed on top of the Strainer in 90 increments. Normal
installation is with vent ports facing front/back.
B. Familiar with all applicable local codes and ordi-
nances covering the type of service, where the flow Installation
meter is used (gasoline, LPG, etc.). The Air/Vapor Eliminator is supplied installed on the strainer.
The only field installation required is piping of vent ports, and
Purpose possible connection to the Air Check Valve (if ordered).
Positive displacement meters cannot distinguish between
liquid, and air/vapors. If air or vapors reach the flow meter, A Top view of AE or VE on FPP strainer
the rotors will turn and an inaccurate measurement results. B
The first step towards avoiding flow meter error due to air or
A: Vent line to collection tank or to storage.
vapors, is to design the system so that air/vapors cannot
enter the lines. In some systems (tank trucks, flow meters LPG service (Vapor Eliminator) alw ays
connected to multiple lines via hoses, etc.) this is not possi- AE/VE back to storage.
ble. In those systems an air or vapor eliminator becomes a on STR
necessary component. B: To Air Check Valve, if incl. in meter assy.
• The air or vapor eliminator is designed to allow free air/ LPG service (Vapor Eliminator) to the
vapors arriving ahead of the liquid to escape before enter- Differential Valve.
ing the measuring chamber.
• Venting of entrained air/vapors depends upon these rising For flow meters without Air Check Valve, pipe one port to
out of the liquid during passage of the strainer. Since collection tank (or storage), and plug the other port. Piping
release of entrained air/vapors is slowed on medium & should always slope towards the collection tank.
high viscosity liquids, efficiency depends upon:
• Size of the strainer below the air/vapor eliminator. Maintenance
Prior to opening or disassembly of any accessory, all
• Flow rate versus line size. internal pressure must be relieved and all liquid must be
Reduced efficiency can be seen in high speed diesel fuel drained. This must be done in accordance with applica-
service. On higher viscosity liquids, such as lubricating ble company and local codes & ordinances.
oil and heavy fuel oils, the air/vapor eliminator efficiency
is essentially limited to free air only.
Depending upon system design, type of service and how • To replace orifice plates (16) and seal ring (20, 17 & 18):
much air/vapors are present, additional components might • Remove cover screws (22), and take off cover plates.
be necessary to eliminate all air/vapors present: • Replace orifice plates.
• Backpressure Valve between strainer & flow meter. • Replace seals (& gasket in Teflon fitted AE).
• Air Check Valve (Differential Valve in LPG service) • Reassemble, tighten cover screws to ft-lbs torque.
on flow meter outlet.
• To replace valve reeds (15), float assembly (13) and/or
Functionality float guide (12):
The Air/Vapor Eliminator is installed in place of a blind cover • Remove mounting screws (9), and lift the air eliminator
on the FPP strainer assembly. It works on a gravity princi- away from the strainer.
ple, with a float riding on a guide (shaft). The float is con- • You now have access to the float guide (12). Replace
nected to two valve reeds, which block the eliminator vent if necessary.
ports when the float is in the UP position (when no air/
vapors are present). • To replace valve reeds (RKAE21) or float assembly
(RKAE20), remove the covers as explained above.
Any air/vapors separating from the liquid during passage of • Release screws (15a) through the vent ports in the air
the strainer will rise into the air/vapor eliminator housing. As eliminator housing (19). The float/valve reed assy
air/vapors accumulate, the float drops. In the DOWN posi- (13/15) can now be removed through the bottom of the
tion it pulls the two valve reeds away from the vent ports. air eliminator.
System pressure now forces the air/vapors out, after which
• Replace with RKAE20 or RKAE21 as needed.
the float rises and valve reeds again block the vent ports.
• Reassemble, tightening mounting screws to ft-lbs
When the Air/Vapor Eliminator vents, it is possible that a few torque.
drops of product will exit together with the air/vapors. This is
normal operation, so vent ports should be piped back to
storage, or to a collection tank, with piping sloping towards
the tank.
2.4
Air Eliminator (Vapor Eliminator for LPG service)
21
20
22
21 20 16
17
22 19
24
18
16 15
15b
17
15a
18 23
14
15c
15d
13
12
10
2.5
Control Valves
A number of different control valves are required in most In loading rack service, always check pump capacity. If
liquid handling systems. Some valves have direct bearing one pump supplies product to multiple flow meters with
on flow meter operation or functionality; other valves serve lower capacity, then the flow meters must be protected
system oriented purposes. against the full flow from the pump when only a single flow
meter is in use. This usually requires a combination preset/
TTS can supply most control valves required for proper flow
rate-of-flow control valve.
meter operation/functionality. Other valves for the system
Preset & Solenoid Control Valves are covered by a separate
must be supplied by the company responsible for system
manual, while the Differential Check Valve is covered in the
design, the local equipment distributor, or the contractor
LPG meter manual. Parts lists for Backpressure & Air
responsible for system installation.
Check valves follow below.
TTS currently manufactures:
• Backpressure Valve Differential Check Valve (LPG Service)
• Air Check Valve The differential check valve (DCV) used in LPG service re-
• Differential Check Valve (LPG service) mains closed, until system pressure is high enough to en-
• Mechanical Preset Valve, max. 1,000 cSt sure that only product in liquid phase will pass the flow me-
ter.
• Solenoid operated valve, 1-stage; max. 50 cSt
• Solenoid operated valve, 2-stage; max. 50 cSt For TS15A, TS20A & TS30A models, this is a straight-
through valve, which mounts directly on flow meter outlet.
By-pass, Check, Isolation, Thermal Relief and other sys-
tem control valves must be supplied by others. For TS06A & TS10A models, this is a right-angle valve. It
can be installed with outlet facing down, up, front or rear.
Mechanical Preset (see separate manual) A 3-way solenoid valve is often included on the tubing be-
2-stage shut-off must be used in preset (batching) service, tween the vapor eliminator and the DCV. This valve serves
whenever the flow rate exceeds 20 GPM (75 lpm). It must as a system security valve.
always be used when batching water directly from municipal
supply line, regardless of flow rate. Backpressure Valve
When a flow meter assembly in-
When preset/batching function is required on liquids with cludes an air eliminator, and there
viscosity exceeding limits shown above, the common is limited system backpressure on
solution is a ball valve or butterfly valve, with a 2-stage the outlet of the flow meter, air
pneumatic operator and ‘Fail Safe’ option (valve closes in eliminator efficiency is less than
case of power failure). While TTS can source such valves, optimum. Some free air might
local sourcing is strongly recommended. This ensures: pass through the flow meter. Add-
1. The most economical price to the buyer. ing a backpressure valve with 8-
2. Ready access to service. 10 PSI (0.6 BAR) spring tension
3. Local supply of spare parts in the future. between strainer outlet and flow
meter inlet will improve on the air
eliminator efficiency.
Electronic Preset (see separate manual)
These valves are based on the same valve body as the me- This valve is installed with the stem pointing into the strainer,
chanical preset valve, with 1 or 2 solenoids added for single with the disc assembly towards the flow meter. It is avail-
or dual stage shut-off. Single stage solenoid valves are in- able in two sizes:
tended as system security (on/off) valves only. For preset VP1901 Used in 2” strainer, with TS10A, TS15A & TS20A
operation dual stage should always be used. Both single &
dual stage solenoid valves are limited to viscosities around VP1930 Used in 3” strainer with TS30A
50 cSt (225 SSU). The relevant repair parts are:
2-stage shut-off must be used in preset (batching) service, VP1901
whenever the flow rate exceeds 20 GPM (75 lpm). It must Replacement spring MS9050 Please
always be used when batching water directly from municipal Washer MS9056 consult for
supply line, regardless of flow rate. Cotter pin MS9055 3” valve
When preset/batching function is required on liquids with
viscosity exceeding limits shown above, refer to above.
For loading rack service, preset valves with additional func-
tions (Rate-of-Flow Control, Check, Pressure reducing or
sustaining, etc) are available from OCV.
2.6
Air Check Valve
Air Check Valve
The air check valve (ACV) is a mechanical valve, which can If this valve is added to an existing flow meter in the field,
be added to flow meters with air eliminator. A connection add items 23 & 24 (see page 2.6) to the air eliminator.
(pipe, hose or tubing, to conform to local codes) must be
In normal operation system pressure overcomes the spring
made between one of the air eliminator vent ports (1” NPT),
behind the piston in the ACV, forcing the valve to open posi-
and the port on the ACV (3/8” NPT). This connection must
tion. When the air eliminator vents, system pressure is con-
be made at time of installation.
nected to the back of the piston. With pressure equalized
2" Air Check Valve for 3" Air Check Valve for
TS10A, TS15A & TS20A TS30A
VP2250-1 VP2257-1 VP2310-1 VP2313-1
QTY QTY
REF DES C R I P T I O N Viton Teflon Viton Teflon
- Mounting adaptors:
- not applicable
1" x 2" adaptor for TS10A only 1 FK1209 FK1209-T
1 Valve body 1 MP2450-1 MP2450-1 1 MP2332 MP2332
2 Shaft/guide for piston 1 MP8050 MP8050 1 MP8038 MP8038
3 Spring 1 MP9207 MP9207 1 MS9211 MS9211
4 Piston 1 MP2451 MP2449 1 MP2654 ?
5 U-cup seal 1 SL1332-U SL2230-U 1 SL1419-U SL2419-U
6 Seat ring 1 MP8052 MP8052 1 MP2653 MP2653
7 Screw, seat ring 2 FS0658 FS0658 2 FS0658 FS0658
8 Com panion Flange 1 1
9 Gasket, com panion flange 1 See Sect. 2, page 7 1 See Sect. 2, page 7
10 Screw, companion flange 4 4
11 Plug to retrofit Air Elim. (#25) 1 MS2010 MS2010 1 MS2010 MS2010
12 Plug to retrofit Air Elim. (#26) 1 MS2010-1 MS2010-1 1 MS2010-1 MS2010-1
2.7
Other TTS Flow Meter Products
S IZ E G P M P SI
TS10A 1" 40 15 0 & 4 0 0
H a rdc o a t
TS15A 1½" 60 15 0 & 4 0 0
A no dize d
TS20A A lum inum 2" 15 0 15 0 & 4 0 0
TS20A V06 AL TS30A 3" 2 0 0 + 15 0 & 4 0 0
Also available with mechanical TS10C 1" 40 15 0 & 4 0 0
preset/valve and/or ticket printer TS15C 1½" 60 15 0 & 4 0 0
316SS
TS20A F63 AA2UAS428 TS20C 2" 15 0 15 0 & 4 0 0
Temperature compensated, TS30C 3" 2 0 0 + 15 0 & 2 9 0
with optional solenoid valve
TM Series, TN Series,
Positive Displacement, oval gear principle, 1/4” - 3/4” Positive Displacement, nutating disc principle.
Linearity: ±0.5% with 10:1 turn-down. The economical alternative with moderate accuracy.
TM06A
with ELNC
register
TM04D with
CC56 in NEMA 4X
S IZ E G P M P SI
TM03A H a rdc o a t 3/8" 3 15 0 0
TM04A A no dize d 1/2" 10 15 0 0
S IZ E P SI V is c o s it y C a pa c it y
TM06D TM06A A lum inum 3/4" 20 15 0 0
TN740A 1" 10 0 0 15 0 + c S t 10 G P M
with TM02D 1/4" 0 .3 15 0 0
TN760A 1.1/2" 4 0 0 15 0 + c S t 15 G P M
CC56 in TM03D 3/8" 3 15 0 0 & 2 5 0 0
316SS TN860A 1.1/2" 15 0 0 .7 - 15 c S t 60 GP M
NEMA 7/4X TM04D 1/2" 10 15 0 0 & 2 5 0 0
TM06D 3/4" 20 15 0 0