2. PROCEDURES
2.1 Determine the turn ratio of the transformer with 220V input and 2 X 9V output.
2.2 Assemble the circuit with 1K ohm load at point (4&5) but without the filter capacitors and
regulators
2.3 Measure the different test points using VOM and Oscilloscope. Tabulate and draw the true
to scale waveforms. ( Test points: 1&2, 1&3, 1&4, 1&5, 4&5)
2.4 Complete the circuit with filter capacitors, 5V+/- voltage regulators, and 1K ohm load.
2.5 Measure the different test points using VOM and Oscilloscope. Tabulate and draw the true
to scale waveforms. (Test points: 1&2, 1&3, 1&4, 1&5, 4&5, 1&6, 1&7, 6&7)
Determine the value of the load resistor that requires 1Amp. at 10V (Regulator Current
rating and the total Output Voltage Vo). This is the minimum load RL =, with this value as
load, the circuit will be operating at the maximum rated values.
2.6 Connect the computed minimum value. Measure the output voltages at points (1&6, 1&7,
6&7) Tabulate the result. V@1&6; V@1&7; V@6&7. Are the voltages at the regulator value?
2.7 Determine the minimum value of the load resistors that will deliver constant output voltage.
Load resistor 100 times higher than the minimum computed value of the load resistor.
3. CONCLUSION
3.1 Explain in detail the operation of the circuit.
3.2 Explain in detail the effect of varying the load to the output voltage.