Professional Documents
Culture Documents
GT Converter2
Version3
Before using this product, read this manual and the relevant manuals introduced in this manual carefully
and handle the product correctly with full attention to safety.
Note that these precautions apply only to this product.
In this manual, the safety instructions are ranked as "WARNING" and "CAUTION".
Note that failure to observe the CAUTION level instructions may also lead to serious results
depending on the circumstances.
Be sure to observe the instructions of both levels to ensure personal safety.
Please keep this manual in accessible place and be sure to forward it to the end user.
A-1
CAUTIONS FOR USING THIS SOFTWARE
1. Required PC memory
The processing may be terminated by Windows on a personal computer of which main memory capacity is less than 64M
bytes. Make sure to secure the capacity of 64 M bytes or more.
4. OS setting
Set the font size as "Small Font" when setting OS (Windows) screen.
The GT Designer3 dialog box cannot be displayed correctly if the font size is set as "Large font".
A-2
INTRODUCTION
Thank you for purchasing Mitsubishi Graphic Operation Terminal (Mitsubishi GOT).
Prior to use, read this manual to fully understand the functions and performance of the GOT.
CONTENTS
1. OVERVIEW
1.1 Features........................................................................................................................................... 1 - 1
2. SYSTEM CONFIGURATION
2.1 Operating Environment.................................................................................................................... 2 - 1
3. SPECIFICATIONS
3.1 Compatible File Formats.................................................................................................................. 3 - 1
A-3
APPENDICES
Appendix1 Conversion Specifications for GOT800 Series ....................................................................App - 1
Appendix.1.1 Graphics Conversion specification ..............................................................................App - 1
Appendix.1.2 Conversion specifications for sprites ...........................................................................App - 2
Appendix2 Conversion Specifications for GP-PRO/PB III Series ..........................................................App - 3
Appendix.2.1 Conversion specifications of project data ....................................................................App - 3
Appendix.2.2 GP type........................................................................................................................App - 9
Appendix.2.3 PLC type....................................................................................................................App - 11
Appendix.2.4 Screen information ....................................................................................................App - 13
Appendix.2.5 Graphic data ..............................................................................................................App - 13
Appendix.2.6 Tag information..........................................................................................................App - 14
Appendix.2.7 Parts information .......................................................................................................App - 17
Appendix.2.8 D-Script......................................................................................................................App - 18
Appendix.2.9 LS area ......................................................................................................................App - 23
REVISIONS
A-4
MANUALS
SH-080866ENG
GT Designer3 Version1 Screen Design Manual (Fundamentals) 1/2, 2/2 Stored in DVD-ROM
(1D7MB9)
SH-080867ENG
GT Designer3 Version1 Screen Design Manual (Functions) 1/2, 2/2 Stored in DVD-ROM
(1D7MC1)
SH-080861ENG
GT Simulator3 Version1 Operating Manual for GT Works3 Stored in DVD-ROM
(1D7MB1)
SH-080862ENG
GT Converter2 Version3 Operating Manual for GT Works3 Stored in DVD-ROM
(1D7MB2)
Connection manuals
Manual Number
Manual Name Packaging
(Model code)
SH-080868ENG
GOT1000 Series Connection Manual (Mitsubishi Products) for GT Works3 Stored in DVD-ROM
(1D7MC2)
SH-080869ENG
GOT1000 Series Connection Manual (Non-Mitsubishi Products 1) for GT Works3 Stored in DVD-ROM
(1D7MC3)
SH-080870ENG
GOT1000 Series Connection Manual (Non-Mitsubishi Products 2) for GT Works3 Stored in DVD-ROM
(1D7MC4)
GOT1000 Series Connection Manual (Microcomputer, MODBUS Products, Peripherals) for GT SH-080871ENG
Stored in DVD-ROM
Works3 (1D7MC5)
SH-080858ENG
GOT1000 Series Gateway Functions Manual for GT Works3 Stored in DVD-ROM
(1D7MA7)
SH-080859ENG
GOT1000 Series MES Interface Function Manual for GT Works3 Stored in DVD-ROM
(1D7MA8)
SH-080863ENG
GOT1000 Series User's Manual (Extended Functions, Option Functions) for GT Works3 Stored in DVD-ROM
(1D7MB3)
GT SoftGOT1000 manuals
Manual Number
Manual Name Packaging
(Model code)
SH-080860ENG
GT SoftGOT1000 Version3 Operating Manual for GT Works3 Stored in DVD-ROM
(1D7MA9)
A-5
GT16 manuals
Manual Number
Manual Name Packaging
(Model code)
SH-080928ENG
GT16 User's Manual (Hardware) Stored in DVD-ROM
(1D7MD3)
SH-080929ENG
GT16 User's Manual (Basic Utility) Stored in DVD-ROM
(1D7MD4)
JY997D41201
GT16 Handy GOT User's Manual Stored in DVD-ROM JY997D41202
(09R821)
GT15 manuals
Manual Number
Manual Name Packaging
(Model code)
SH-080528ENG
GT15 User's Manual Stored in DVD-ROM
(1D7M23)
GT14 manuals
Manual Number
Manual Name Packaging
(Model code)
JY997D44801
GT14 User's Manual Stored in DVD-ROM
(09R823)
GT12 manuals
Manual Number
Manual Name Packaging
(Model code)
SH-080977ENG
GT12 User's Manual Stored in DVD-ROM
(1D7ME1)
GT11 manuals
Manual Number
Manual Name Packaging
(Model code)
JY997D17501
GT11 User's Manual Stored in DVD-ROM
(09R815)
JY997D20101
GT11 Handy GOT User's Manual Stored in DVD-ROM JY997D20102
(09R817)
GT10 manuals
Manual Number
Manual Name Packaging
(Model code)
JY997D24701
GT10 User's Manual Stored in DVD-ROM
(09R819)
A-6
QUICK REFERENCE
Creating a project
Obtaining the specifications and operation methods of GT Designer3
Simulating a created project on a personal computer GT Simulator3 Version1 Operating Manual for GT Works3
Obtaining information of Non-Mitsubishi products applicable to the GOT • GOT1000 Series Connection Manual (Non-Mitsubishi
Products 1) for GT Works3
• GOT1000 Series Connection Manual (Non-Mitsubishi
Connecting Non-Mitsubishi products to the GOT
Products 2) for GT Works3
A-7
Others
Obtaining specifications (including part names, external dimensions, and • GT16 User's Manual (Hardware)
options) of each GOT • GT16 Handy GOT User's Manual
• GT15 User's Manual
• GT14 User's Manual
• GT12 User's Manual
Installing the GOT • GT11 User's Manual
• GT11 Handy GOT User's Manual
• GT10 User's Manual
Configuring the gateway function GOT1000 Series Gateway Functions Manual for GT Works3
Using a personal computer as the GOT GT SoftGOT1000 Version3 Operating Manual for GT Works3
A-8
ABBREVIATIONS AND GENERIC TERMS
GOT
Abbreviations and generic terms Description
GT1695 GT1695M-X Abbreviation of GT1695M-XTBA, GT1695M-XTBD
GT1685 GT1685M-S Abbreviation of GT1685M-STBA, GT1685M-STBD
GT1675M-S Abbreviation of GT1675M-STBA, GT1675M-STBD
GT1675 GT1675M-V Abbreviation of GT1675M-VTBA, GT1675M-VTBD
GT1675-VN Abbreviation of GT1675-VNBA, GT1675-VNBD
GT1672 GT1672-VN Abbreviation of GT1672-VNBA, GT1672-VNBD
GT1665M-S Abbreviation of GT1665M-STBA, GT1665M-STBD
GT1665
GT1665M-V Abbreviation of GT1665M-VTBA, GT1665M-VTBD
GT1662 GT1662-VN Abbreviation of GT1662-VNBA, GT1662-VNBD
GT16 Abbreviation of GT1695, GT1685, GT1675, GT1672, GT1665, GT1662, GT1655, GT16 Handy GOT
GT1595 GT1595-X Abbreviation of GT1595-XTBA, GT1595-XTBD
GT1585V-S Abbreviation of GT1585V-STBA, GT1585V-STBD
GT1585
GT1585-S Abbreviation of GT1585-STBA, GT1585-STBD
GT1575V-S Abbreviation of GT1575V-STBA, GT1575V-STBD
GT1575-S Abbreviation of GT1575-STBA, GT1575-STBD
GT157 GT1575-V Abbreviation of GT1575-VTBA, GT1575-VTBD
GT1575-VN Abbreviation of GT1575-VNBA, GT1575-VNBD
GT1572-VN Abbreviation of GT1572-VNBA, GT1572-VNBD
GT1565-V Abbreviation of GT1565-VTBA, GT1565-VTBD
GT156
GT1562-VN Abbreviation of GT1562-VNBA, GT1562-VNBD
GT1555-V Abbreviation of GT1555-VTBD
A-9
Abbreviations and generic terms Description
GT16
Handy GT1665HS-V Abbreviation of GT1665HS-VTBD
Handy GOT
GOT1000 GOT GT11 GT1155HS-Q Abbreviation of GT1155HS-QSBD
Series
Handy
GOT GT1150HS-Q Abbreviation of GT1150HS-QLBD
Communication unit
Abbreviations and generic terms Description
GT15-QBUS, GT15-QBUS2, GT15-ABUS, GT15-ABUS2, GT15-75QBUSL, GT15-75QBUS2L,
Bus connection unit
GT15-75ABUSL, GT15-75ABUS2L
Serial communication unit GT15-RS2-9P, GT15-RS4-9S, GT15-RS4-TE
RS-422 conversion unit GT15-RS2T4-9P, GT15-RS2T4-25P
Ethernet communication unit GT15-J71E71-100
MELSECNET/H communication unit GT15-J71LP23-25, GT15-J71BR13
Option unit
Abbreviations and generic terms Description
Printer unit GT15-PRN
Video input unit GT16M-V4, GT15V-75V4
RGB input unit GT16M-R2, GT15V-75R1
Video/RGB unit
Video/RGB input unit GT16M-V4R1, GT15V-75V4R1
RGB output unit GT16M-ROUT, GT15V-75ROUT
Multimedia unit GT16M-MMR
CF card unit GT15-CFCD
A - 10
Option
Abbreviations and generic terms Description
GT05-MEM-16MC, GT05-MEM-32MC, GT05-MEM-64MC, GT05-MEM-128MC,
CF card GT05-MEM-256MC, GT05-MEM-512MC, GT05-MEM-1GC, GT05-MEM-2GC,
Memory card GT05-MEM-4GC, GT05-MEM-8GC, GT05-MEM-16GC
NZ1MEM-2GBSD, NZ1MEM-4GBSD, NZ1MEM-8GBSD, NZ1MEM-16GBSD,
SD card
L1MEM-2GBSD, L1MEM-4GBSD
Memory card adaptor GT05-MEM-ADPC
GT16-MESB, GT15-FNB, GT15-QFNB, GT15-QFNB16M,
Option function board
GT15-QFNB32M, GT15-QFNB48M, GT11-50FNB, GT15-MESB48M
Battery GT15-BAT, GT11-50BAT
GT16-90PSCB, GT16-90PSGB, GT16-90PSCW, GT16-90PSGW,
GT16-80PSCB, GT16-80PSGB, GT16-80PSCW, GT16-80PSGW,
GT16-70PSCB, GT16-70PSGB, GT16-70PSCW, GT16-70PSGW,
For GT16 GT16-60PSCB, GT16-60PSGB, GT16-60PSCW, GT16-60PSGW,
GT16-50PSCB, GT16-50PSGB, GT16-50PSCW, GT16-50PSGW,
GT16-90PSCB-012, GT16-80PSCB-012, GT16-70PSCB-012,
GT16-60PSCB-012, GT16-50PSCB-012, GT16H-60PSC
GT15-90PSCB, GT15-90PSGB, GT15-90PSCW, GT15-90PSGW,
GT15-80PSCB, GT15-80PSGB, GT15-80PSCW, GT15-80PSGW,
For GT15 GT15-70PSCB, GT15-70PSGB, GT15-70PSCW, GT15-70PSGW,
Protective Sheet GT15-60PSCB, GT15-60PSGB, GT15-60PSCW, GT15-60PSGW,
GT15-50PSCB, GT15-50PSGB, GT15-50PSCW, GT15-50PSGW
For GT14 GT14-50PSCB, GT14-50PSGB, GT14-50PSCW, GT14-50PSGW
For GT12 GT11-70PSCB, GT11-65PSCB
GT11-50PSCB, GT11-50PSGB, GT11-50PSCW, GT11-50PSGW,
For GT11
GT11H-50PSC
GT10-50PSCB, GT10-50PSGB, GT10-50PSCW, GT10-50PSGW,
GT10-40PSCB, GT10-40PSGB, GT10-40PSCW, GT10-40PSGW,
For GT10
GT10-30PSCB, GT10-30PSGB, GT10-30PSCW, GT10-30PSGW,
GT10-20PSCB, GT10-20PSGB, GT10-20PSCW, GT10-20PSGW
GT05-90PCO, GT05-80PCO, GT05-70PCO, GT05-60PCO, GT05-50PCO,
Protective cover for oil
GT16-50PCO, GT10-40PCO, GT10-30PCO, GT10-20PCO
USB environmental protection cover GT16-UCOV, GT16-50UCOV, GT15-UCOV, GT14-50UCOV, GT11-50UCOV
Stand GT15-90STAND, GT15-80STAND, GT15-70STAND, A9GT-50STAND, GT05-50STAND
GT15-70ATT-98, GT15-70ATT-87, GT15-60ATT-97, GT15-60ATT-96,
Attachment
GT15-60ATT-87, GT15-60ATT-77, GT15-50ATT-95W, GT15-50ATT-85
GT16-90XLTT, GT16-80SLTT, GT16-70SLTT, GT16-70VLTT, GT16-70VLTTA, GT16-70VLTN,
Backlight GT16-60SLTT, GT16-60VLTT, GT16-60VLTN, GT15-90XLTT, GT15-80SLTT, GT15-70SLTT,
GT15-70VLTT, GT15-70VLTN, GT15-60VLTT, GT15-60VLTN
Multi-color display board GT15-XHNB, GT15-VHNB
Connector conversion box GT11H-CNB-37S, GT16H-CNB-42S
Emergency stop sw guard cover GT11H-50ESCOV, GT16H-60ESCOV
Memory loader GT10-LDR
Memory board GT10-50FMB
Panel-mounted USB port extension GT14-C10EXUSB-4S, GT10-C10EXUSB-5S
A - 11
Software
Abbreviations and generic terms Description
GT Works3 Abbreviation of the SW DND-GTWK3-E and SW DND-GTWK3-EA
GT Designer3 Abbreviation of screen drawing software GT Designer3 for GOT1000 series
GT Simulator3 Abbreviation of screen simulator GT Simulator3 for GOT1000/GOT900 series
GT SoftGOT1000 Abbreviation of monitoring software GT SoftGOT1000
GT Converter2 Abbreviation of data conversion software GT Converter2 for GOT1000/GOT900 series
GT Designer2 Classic Abbreviation of screen drawing software GT Designer2 Classic for GOT900 series
GT Designer2 Abbreviation of screen drawing software GT Designer2 for GOT1000/GOT900 series
iQ Works Abbreviation of iQ Platform compatible engineering environment MELSOFT iQ Works
Generic term for integrated development environment software included in the SW DNC-IQWK (iQ
MELSOFT Navigator
Platform compatible engineering environment MELSOFT iQ Works)
MELSOFT iQ AppPortal SW DND-IQAPL-M type integrated application management software
Abbreviation of SW DND-GXW3-E and SW DND-GXW3-EA type programmable controller
GX Works3
engineering software
Abbreviation of SW DNC-GXW2-E and SW DNC-GXW2-EA type programmable controller
GX Works2
engineering software
GX Simulator2 Abbreviation of GX Works2 with the simulation function
Abbreviation of SW D5C-LLT-E(-EV) type ladder logic test tool function software packages
GX Simulator
(SW5D5C-LLT (-EV) or later versions)
GX Developer Abbreviation of SW D5C-GPPW-E(-EV)/SW D5F-GPPW-E type software package
GX LogViewer Abbreviation of SW DNN-VIEWER-E type software package
PX Developer Abbreviation of SW D5C-FBDQ-E type FBD software package for process control
MT Works2 Abbreviation of motion controller engineering environment MELSOFT MT Works2(SW DND-MTW2-E)
MT Developer Abbreviation of SW RNC-GSV type integrated start-up support software for motion controller Q series
MR Configurator2 Abbreviation of SW DNC-MRC2-E type Servo Configuration Software
MR Configurator Abbreviation of MRZJW -SETUP E type Servo Configuration Software
FR Configurator Abbreviation of Inverter Setup Software (FR-SW -SETUP-WE)
NC Configurator Abbreviation of CNC parameter setting support tool NC Configurator
Abbreviation of parameter setting, monitoring, and testing software packages for FX3U-20SSC-H
FX Configurator-FP
(SW D5C-FXSSC-E)
FX3U-ENET-L Configuration tool Abbreviation of FX3U-ENET-L type Ethernet module setting software (SW1D5-FXENETL-E)
RT ToolBox2 Abbreviation of robot program creation software (3D-11C-WINE)
MX Component Abbreviation of MX Component Version (SW D5C-ACT-E, SW D5C-ACT-EA)
MX Sheet Abbreviation of MX Sheet Version (SW D5C-SHEET-E, SW D5C-SHEET-EA)
QnUDVCPU & LCPU Logging Configuration
Abbreviation of QnUDVCPU & LCPU Logging Configuration Tool (SW1DNN-LLUTL-E)
Tool
A - 12
Others
Abbreviations and generic terms Description
IAI Abbreviation of IAI Corporation
AZBIL Abbreviation of Azbil Corporation (former Yamatake Corporation)
OMRON Abbreviation of OMRON Corporation
KEYENCE Abbreviation of KEYENCE CORPORATION
KOYO EI Abbreviation of KOYO ELECTRONICS INDUSTRIES CO., LTD.
SHARP Abbreviation of Sharp Manufacturing Systems Corporation
JTEKT Abbreviation of JTEKT Corporation
SHINKO Abbreviation of Shinko Technos Co., Ltd.
CHINO Abbreviation of CHINO CORPORATION
TOSHIBA Abbreviation of TOSHIBA CORPORATION
TOSHIBA MACHINE Abbreviation of TOSHIBA MACHINE CO., LTD.
HITACHI IES Abbreviation of Hitachi Industrial Equipment Systems Co., Ltd.
HITACHI Abbreviation of Hitachi, Ltd.
FUJI Abbreviation of FUJI ELECTRIC CO., LTD.
PANASONIC Abbreviation of Panasonic Corporation
PANASONIC INDUSTRIAL DEVICES SUNX Abbreviation of Panasonic Industrial Devices SUNX Co., Ltd.
YASKAWA Abbreviation of YASKAWA Electric Corporation
YOKOGAWA Abbreviation of Yokogawa Electric Corporation
ALLEN-BRADLEY Abbreviation of Allen-Bradley products manufactured by Rockwell Automation, Inc.
GE Abbreviation of GE Intelligent Platforms
LS IS Abbreviation of LS Industrial Systems Co., Ltd.
SCHNEIDER Abbreviation of Schneider Electric SA
SICK Abbreviation of SICK AG
SIEMENS Abbreviation of Siemens AG
RKC Abbreviation of RKC INSTRUMENT INC.
HIRATA Abbreviation of Hirata Corporation
MURATEC Abbreviation of Muratec products manufactured by Muratec Automation Co., Ltd.
PLC Abbreviation of programmable controller
Temperature controller Generic term for temperature controller manufactured by each corporation
Indicating controller Generic term for indicating controller manufactured by each corporation
Control equipment Generic term for control equipment manufactured by each corporation
CHINO controller Abbreviation of indicating controller manufactured by CHINO CORPORATION
PC CPU module Abbreviation of PC CPU Unit manufactured by CONTEC CO., LTD
GOT (server) Abbreviation of GOTs that use the server function
GOT (client) Abbreviation of GOTs that use the client function
Generic term for the protocol designed to use MODBUS protocol messages on a serial
MODBUS/RTU
communication
MODBUS/TCP Generic term for the protocol designed to use MODBUS protocol messages on a TCP/IP network
A - 13
HOW TO USE THIS MANUAL
: Refers to information
required for operation.
: Refers to information
useful for operation.
The above is different from the actual page, as it is provided for explanation only.
A - 14
1
1. OVERVIEW
OVERVIEW
This manual explains the specifications and operation methods of GT Converter2.
POINT 2
Installation method of GT Converter2
CONFIGURATION
For the installation method of GT Converter2, refer to the following manuals.
GT Works3 Installation Procedure Manual
SYSTEM
1.1 Features 3
SPECIFICATIONS
GT Converter2 is software that converts project data created by existing screen editor software into those available for
use on GT Designer3 or GT Designer2 Classic.
GT CONVERTER2
SCREEN LAYOUT
A900 format).
OPERATION METHODS
GT CONVERTER2
GP-PRO/PB series GT Converter2 GT Designer3
Convertion failure!
OVERVIEW
Because GT Converter2 is installed into the same computer where GT Designer3 is installed, the system configuration is
the same as that of GT Designer3.
System Configuration• • • GT Designer3 Version Screen Design Manual (Fundamentals) 2
2.1 Operating Environment
CONFIGURATION
SYSTEM
Item Description
SPECIFICATIONS
Microsoft Windows 10 Home (English version)*2*3*5*7
Microsoft Windows 8.1 Enterprise (English version)*2*3*5*7*8*9
Microsoft Windows 8.1 Pro (English version)*2*3*5*7*8*9
Microsoft Windows 8.1 (English version)*2*3*5*7*8
Microsoft Windows 8 Enterprise (English version)*2 *3 *5 *7*8*9
Microsoft Windows 8 Pro (English version)*2*3*5*7*8*9 4
Microsoft Windows 8 (English version)*2 *3 *5 *7*8
Microsoft Windows 7 Ultimate (English version)*2 *3 *5 *6 *7
GT CONVERTER2
SCREEN LAYOUT
Microsoft Windows XP Professional Service Pack3 or later
(English version)*1 *3 *4 Microsoft Windows 7 Enterprise (English version)*2 *3 *5 *6 *7
Microsoft Windows XP Home Edition Service Pack3 or later Microsoft Windows 7 Professional (English version)*2 *3 *5 *6 *7
Operating system
(English version)*1 *3 *4 Microsoft Windows 7 Home Premium (English version)*2 *3 *5 *7
Microsoft Windows 2000 Professional Service Pack4 Microsoft Windows 7 Starter (English version)*2 *3 *4
(English version)*1 Microsoft® Windows Vista® Ultimate Service Pack1 or later (English
version)*2 *3 *4
5
OPERATION METHODS
Microsoft Windows Vista Enterprise Service Pack1 or later
(English version)*2 *3 *4
GT CONVERTER2
Microsoft® Windows Vista® Business Service Pack1 or later (English
version)*2 *3 *4
Microsoft® Windows Vista® Home Premium Service Pack1 or later
(English version)*2 *3 *4
Microsoft® Windows Vista® Home Basic Service Pack1 or later
(English version)*2 *3 *4
APPENDICES
32-bit OSs: 1GB or more recommended
Memory 512MB or more
64-bit OSs: 2GB or more recommended
Others The mouse, keyboard, printer, and DVD-ROM drive must be compatible with the above OS.
OVERVIEW
3.1 Compatible File Formats
2
This section explains GT Converter2 compatible file formats before and after conversion.
CONFIGURATION
Conversion source file format
conversion source
SYSTEM
3
SPECIFICATIONS
SW3NIW-A8GOTP/ GT Converter2 GT Designer3
GP-PRO/PB series
4
(1) Digital Electronics Corporation's screen editor software
GT CONVERTER2
SCREEN LAYOUT
The following can be specified as conversion source file formats.
OPERATION METHODS
GP-PRO/PB C-Package03
GT CONVERTER2
GP-PRO/PB (DOS Version) ProPB/DOS project format (*.pro)
POINT
Precautions for converting project data created by screen editor software from Digital Electronics
Corporation
When project data created by the screen editor software of GP-PRO/PB series from Digital Electronics
APPENDICES
Corporation are not correctly converted, open and save the data again with the software, and then convert the
data. As a result, the data may be correctly converted.
For details on the screen editor software of GP-PRO/PB series manufactured by Digital Electronics Corporation,
refer to the following.
Manual for GP-PRO/PB series manufactured by Digital Electronics Corporation
POINT
To Reuse Project Data Created for A64GOT or A77GOT
Using SW3NIW-A8GOTP, convert the project data for A64GOT or A77GOT into GOT800 file format.
The project data in GOT800 format can be converted into GT Designer2 project data using GT Converter2.
Refer to the following manual for the details.
SW3NIW-A8GOTP Graphic Settings Software Package Operating Manual (Monitor Screen
Creation Manual) (IB-66793) (Section 2.5 Using Previously Created GOT Data)
The following can be specified for the file formats after conversion.
POINT
Data Size of Converted File
When checking the data size of the file after conversion, save the project data on GT Designer3 once, and then re-
open the saved project data.
The data size may not be displayed properly if this is not performed.
OVERVIEW
4.1 Screen Layout and Basic Operations
2
4.1.1 Screen layout
CONFIGURATION
The screen is laid out as shown below.
SYSTEM
Title bar
Menu bar
Toolbar
4.2 Menu
Section Bar
4.2 Menu bar
4.3 Toolbar
Section 4.3 Toolbar 3
SPECIFICATIONS
4
GT CONVERTER2
SCREEN LAYOUT
Dropdown menu 5
OPERATION METHODS
GT CONVERTER2
4.1.2 Basic operations
APPENDICES
To execute an item, click to put the
mark.
(2) Radio button
Click for the item to be selected.
(1) Check box
Project
From the Project menu, project data can be opened and GT Converter2 can
be exited.
Conversion
From the Conversion menu, the conversion settings screen can be
displayed.
4.3 Toolbar
The following toolbar are provided.
Name Content
OVERVIEW
POINT
Before viewing PDF format manual 2
To view the PDF manual, GT Manual and Adobe
Reader is required to be installed.
CONFIGURATION
Operation method
SYSTEM
1. Click on each menu item under [Help].
Item Description 3
[Index (GOT 1000)], [Index (GOT900)] This item is used for viewing a PDF manual.
SPECIFICATIONS
[About GT Converter2...] This item is used for confirming the GT Converter2 version.
[Connection to MITSUBISHI ELECTRIC FA Global Website...] Connects to the MITSUBISHI ELECTRIC FA Global Website.
GT CONVERTER2
SCREEN LAYOUT
Click
5
OPERATION METHODS
GT CONVERTER2
*The above is user for explanation only and differs from the actual page.
*The above is user for explanation only and differs from the actual page.
Item Description
OVERVIEW
5.1 Operating Procedures
2
The GT Converter2 operating procedures are shown below.
CONFIGURATION
Start
SYSTEM
Start GT Converter2. • • •
SPECIFICATIONS
Open conversion source file. • • • 5.2 Opening Conversion Source File
4
• • • 5.3 Conversion
GT CONVERTER2
SCREEN LAYOUT
Set conversion method and start conversion.
View conversion log and check result. • • • 5.4 Checking Conversion Result
OPERATION METHODS
End
GT CONVERTER2
POINT
To Reuse Project Data Created for A64GOT or A77GOT
Using SW3NIW-A8GOTP, convert the project data for A64GOT or A77GOT into GOT800 file format.
The project data in GOT800 format can be converted into GT Designer2 project data using GT Converter2.
Refer to the following manual for the details.
APPENDICES
SW3NIW-A8GOTP Graphic Settings Software Package Operating Manual (Monitor Screen
Creation Manual) (IB-66793) (Section 2.5 Using Previously Created GOT Data)
• Click (Open).
• Select [Project] [Open] from the menu.
2. Make the following settings and click the Open button to open the conversion source file.
Item Description
Lock in Select the location where the conversion source file is saved.
OVERVIEW
2
CONFIGURATION
SYSTEM
Conversion
applicability
SPECIFICATIONS
Item Description
Displays the type of the screen editing software used to create the conversion source file.
ProPB3 for Windows Project: Displayed when the conversion source file was created by any of the following software. 4
• GP-PRO/PBIII for Windows95
GT CONVERTER2
SCREEN LAYOUT
• GP-PRO/PBIII for Windows
Type • GP-PRO/PBIII C-Package01
• GP-PRO/PBIII C-Package02
• GP-PRO/PBIII C-Package03
ProPB3 for DOS Project : Displayed when the conversion source file was created by GP-PRO/PBIII (DOS version).
A8GOTP Project : Displayed when the conversion source file was created by SW3NIW-A8GOTP.
Title Displays the comment (GP-PRO/PBIII series) or project title (SW3NIW-A8GOTP) set for the project.
5
OPERATION METHODS
PLC Displays the PLC type set for the project.
GT CONVERTER2
Terminal Displays the GP type (GP-PRO/PBIII series) or GOT type (SW3NIW-A8GOTP) set for the project.
APPENDICES
1. Performing either of the following operations with the conversion source file open ( 5.2 Opening Conversion
Source File) displays the conversion settings screen.
2. On the conversion settings screen, select the folder in the output directory and set the conversion methods.
Click the OK button to start the conversion.
The conversion logs showing the conversion results are displayed. ( 5.4 Checking Conversion Result)
Clicking the Cancel button during conversion will stop the conversion.
Output Directory Setting • • • • • • • • • • • • • 5.3.1 Output directory setting
Conversion Method Settings • • • • • • • • • • 5.3.2 Conversion option settings
OVERVIEW
The file type of the converted files varies depending on the conversion format settings ( 5.3.2
Conversion option settings)
Conversion format File name
2
GOT2000 The following 2 types of files are output after conversion.
• "<filename>.GTCNV"
CONFIGURATION
• "Script\Sc<Sequence number>.txt" (Output into "Script" folder)
The name of the source project file is entered in <filename>. Example:"AssemblyLine.prw"
(Conversion) "AssemblyLine.g1"
SYSTEM
A number greater than 1 is placed in <Sequence number>.
SPECIFICATIONS
The name of the source project file is entered in <filename>. Example:"AssemblyLine.prw"
(Conversion) "AssemblyLine.g1"
A number greater than 1 is placed in <Sequence number>.
GT CONVERTER2
SCREEN LAYOUT
• "PACKAGE.A9"
• "GOTWAV00.A9"
• "Script\Sc<Sequence number>.txt" (Output into "Script" folder)
A number greater than 1 is placed in <Sequence number>.Example: "AssemblyLine.prw"
(Conversion) "A9GOTP.GOT"
OPERATION METHODS
When handling the files (copy/move/delete), perform the operation on all of these files together.
GT CONVERTER2
APPENDICES
1. Clicking on the Select button provided for "Output Directory:" on the conversion settings screen displays the
Browse for Folder screen.
2. Select a folder on the Browse for Folder screen and click the OK button.
OVERVIEW
1. Make the following settings.
CONFIGURATION
SYSTEM
3
SPECIFICATIONS
(When converting the project data for GOT800 series.) (When converting the project data for GP-PRO/PB series.)
GT CONVERTER2
SCREEN LAYOUT
Win DOS
When checked, the rectangle filled with a background color is placed behind the
character string.
Applicable only when "GOT-A900" format is selected for “Output Type”.
OPERATION METHODS
For GOT1000 series, a background color can be converted regardless of this
GT CONVERTER2
setting item.
When checked, the base screen in the conversion source file is converted into a
base screen and parts.
Convert Base Screen into
In this case, only the graphic data placed on the base screen of the conversion
Parts.
source file are converted into parts.
When not checked, it is converted into the base screen only.
When converting the L tag into parts display, set the part type. When checked, it
The target base screen of is set to parts.
APPENDICES
the L tag settings is When not checked, it is set to the base screen.
converted to parts. This option setting is available when "Convert Base Screen into Parts." shown
above is check-marked.
When checked, the password for conversion source file is converted into the
Convert the password.
password for [Data Transmission/Utility].
Item Description
Displays the conversion source objects ( Conversion source object list) and messages ( 5.4.1 Conversion log
Message list).
Conversion source objects are displayed only when a diagram, tag, or part has been converted.
OK button Returns it to the project data screen. ( 5.2 Opening Conversion Source File)
POINT
(1) The Conversion Log Text File
Do not open the conversion log text file during conversion.
If it is open, logs cannot be saved in the text file.
HINT
The folder in which conversion logs are saved and the file name
The conversion logs are saved into the same file specified in the output directory.
5.3.1 Output directory setting
The conversion logs file name is almost the same as the conversion source file name except that the extension is
changed to ".txt".
Example: "AssemblyLine.prw" (Conversion) "AssemblyLine.txt"
OVERVIEW
B_<Number> Base Screen
CONFIGURATION
I_<Number> Image Screen
SYSTEM
O_<Number> Sound
SPECIFICATIONS
F_<Number> Filing Data
----- Others
GT CONVERTER2
SCREEN LAYOUT
Graphic types are displayed when figures have been converted.
tick mark, string, dot, bitmap
Tag IDs or part IDs which are the same as those displayed on the
Other than the above
GP-PRO/PB series' editing screen are displayed.
OPERATION METHODS
GT CONVERTER2
APPENDICES
The following table lists conversion logs and corresponding corrective actions.
Log Conversion
Message Corrective action
code result
1002 Conversion Interrupted. Error Do not press the Cancel button during conversion.
1003 Conversion failed. Error Correct the error occurred before this error.
1004 Error(<Exception code>). Error After the conversion, modify the error screen with GT Designer 2.
2001 Unable to create "<path>". Error Correct the error occurred before this error.
2002 Device conversion error. Warning After the conversion, set the device of the error object again with GT Designer3.
2003 LS Area conversion error. Warning After the conversion, set the device of the error object again with GT Designer3.
2004 Maximum data number exceeded. Error Correct the error data with the screen editor software before conversion.
2005 Data code error. Error Manually perform conversion with GT Designer3 after the conversion.
Modify the characters using screen editor software before conversion so that the
2007 Maximum character string exceeded. Warning
OVERVIEW
number of characters will be the maximum or less.
2009 Data conversion failed. Error Correct the error occurred before this error.
CONFIGURATION
After the conversion, create a substitute for the error object with GT Designer3.
3001 The objects not supported. Error
SYSTEM
Manually create a substitute object.
3003 Figure (Figure no.) conversion failed. Error Correct the error occurred before this error. 3
3004 Tag (Tag name) conversion completed. OK ---
SPECIFICATIONS
3005 Tag (Tag name) conversion failed. Error Correct the error occurred before this error.
3007 Parts (Parts name) conversion failed. Error Correct the error occurred before this error.
GT CONVERTER2
SCREEN LAYOUT
4001 Unable to convert indirect devices. Error
specification" using the screen editor software.
Indirect color specification is not Before conversion, change the color settings of the object to "direct specification"
4002 Warning
supported. using the screen editor software.
Before conversion, change the input code of the object to other than MSB code
4003 Signed MSB not supported. Error
using the screen editor software.
Before conversion, cancel the color block setting of the object using the screen
5
4004 Unable to convert color blocks. Error
OPERATION METHODS
editor software.
GT CONVERTER2
4005 Unable to convert slanted tags. Error Before conversion, set the tag angle to 0 degrees using the screen editor software.
4006 Data compressed. Error Before conversion, decompress the data using the screen editor software.
Before conversion, reduce the number of figures' points to 1,000 or less using the
4007 Maximum points limit exceeded. Warning
screen editor software.
4008 Data error. Error After the conversion, create a substitute for the error object with GT Designer3.
After the conversion, change the position of the character string with GT
APPENDICES
4010 Maximum line spacing limit exceeded. Warning
Designer3.
4011 Unable to convert arrow attributes. Warning After the conversion, draw an arrow using lines with GT Designer3.
4012 Unable to convert BMP image in parts. Error After the conversion, register the BMP image as a part with GT Designer3.
5000 Syntax error. Error Before conversion, correct the script syntax error with the screen editor software.
5001 Unable to convert script trigger. Error After the conversion, manually set the trigger with GT Designer3.
Unsupported special relay is converted After the conversion, set the GD device to an appropriate device with GT
5003 Warning
to GD device. Designer3.
> 2 or more alarm history sprites cannot be placed on the After the conversion, correct the error in the data shown in the
- Info
same screen message with GT Designer3.
- ### All screen common setting file creation phase Info ---
OVERVIEW
- Tag: Convert N-tag into Numerical Display Info ---
After the conversion, correct the error in the data shown in the
2
- Failed to convert devices Info
message with GT Designer3.
CONFIGURATION
- Failed to open the file. Info
Perform the following before conversion.
- Failed to get the file size. Info • Exit the other running applications.
SYSTEM
• Restart Microsoft Windows.
- Unable to secure the memory Info
- Set Overlay Screen <Layer name> Layer <Hierarchy No.> th Info ---
SPECIFICATIONS
- Object: Transform Square/Rectangle Info ---
- Object: Transform Pie (change into Line and Arc) Info ---
- Object: Filled objects are not targeted for conversion Info --- 4
- Object: Transform Filled Polygon (convert into Polygon) Info ---
GT CONVERTER2
SCREEN LAYOUT
- Object: Transform Text Info ---
OPERATION METHODS
- Date (mm/dd/yy) <Date> Info ---
GT CONVERTER2
- Part: Transform Lamp Info ---
APPENDICES
(<coordinate>,<coordinate> - <coordinate>,<coordinate>)
- === Sprite information with memory save will be registered Info ---
> Exceeded the maximum number of characters (12) used for After the conversion, correct the error in the data shown in the
- Info
a file name message with GT Designer3.
- > Detected Z device set for bit specification of word. Info ---
> Exceeded the maximum number of characters (32) used for After the conversion, correct the error in the data shown in the
- Info
a screen title message with GT Designer3.
After the conversion, correct the error in the data shown in the
- Conversion of A8GOTP.got is not performed Info
message with GT Designer3.
- Conversion of Hqfont.a8 is not performed Info After the conversion, correct the error in the data shown in the
- Conversion of PACKAGE.A8 is not performed Info message with GT Designer3.
After the conversion, correct the error in the data shown in the
- Conversion of Parts.a8 is not performed Info
message with GT Designer3.
After the conversion, correct the error in the data shown in the
- Conversion of <File name>.GTCNV is not performed Info
message with GT Designer3.
- Warning!! Excess of device types Info After the conversion, correct the error in the data shown in the
- Warning!! Appropriate color data cannot be found Info message with GT Designer3.
- XXX <File name> Unable to open the file XXX Info Perform the following before conversion.
• Exit the other running applications.
- XXX Failed to write data to PACKAGE.A9 file XXX Info • Restart Microsoft Windows.
After the conversion, correct the error in the data shown in the
- XXX Conversion of this sprite is not performed XXX Info
message with GT Designer3.
After the conversion, correct the error in the data shown in the
- XXX Reaffirm Device No. XXX Info
message with GT Designer3.
OVERVIEW
- XXX Unable to write data to a result display file XXX Info • Exit the other running applications.
• Restart Microsoft Windows.
- XXX Failed to get row information XXX Info
CONFIGURATION
Perform the following before conversion.
- XXX Initialization processing failed XXX Info • Exit the other running applications.
• Restart Microsoft Windows.
SYSTEM
After the conversion, correct the error in the data shown in the
- XXX Detected an improperly set device XXX Info
message with GT Designer3.
SPECIFICATIONS
XXX
- XXX Failed to write data to a conversion termination file XXX Info Perform the following before conversion.
• Exit the other running applications.
- XXX Unable to write into a save destination XXX Info
• Restart Microsoft Windows.
- XXX Failed to get column information XXX Info
GT CONVERTER2
SCREEN LAYOUT
- xxx Failed to convert GOT Type xxx Info
After the conversion, correct the error in the data shown in the
- xxx Failed to write data to Hqfont.a9 file xxx Info
message with GT Designer3.
- xxx Failed to convert PLC Type xxx Info
OPERATION METHODS
- xxx Failed to convert other items xxx Info
GT CONVERTER2
- xxx Failed to register alarm history data xxx Info
APPENDICES
- xxx Failed to convert bar code xxx Info
- xxx Failed to register sprite information with memory save xxx Info
OVERVIEW
- === Detailed comment will be converted Info ---
CONFIGURATION
- === Operation panel will be converted Info ---
SYSTEM
For converting the password, check [Convert Password.] in the
- !!! No password conversion due to the conversion options Info conversion option setting.
---
3
- ### Package information file conversion Info ---
SPECIFICATIONS
- ### Base/window file conversion Info ---
4
- ### Comment file conversion Info ---
GT CONVERTER2
- ### Part file conversion Info ---
SCREEN LAYOUT
- ### Initialization processing Info ---
OPERATION METHODS
Before conversion, remove the commands that are not
GT CONVERTER2
- Sprite code error Info
supported by GT Converter2 with the screen editor software.
APPENDICES
- Failed to write the file. Info • Exit the other running applications.
• Restart Microsoft Windows.
- Failed to write data to the file Info
After the conversion, correct the error in the data shown in the
- Character string is not set Info
message with GT Designer3.
OVERVIEW
- Sprite: Convert Part Movement Info ---
2
5.5 Exiting GT Converter2
CONFIGURATION
SYSTEM
Exit GT Converter2.
SPECIFICATIONS
4
GT CONVERTER2
SCREEN LAYOUT
5
OPERATION METHODS
GT CONVERTER2
APPENDICES
OVERVIEW
Appendix1 Conversion Specifications for GOT800 Series
2
This section explains the conversion specifications of project data for the GOT800 series.
CONFIGURATION
POINT
SYSTEM
(1) Precautions for data conversion
GT Converter2 will not be liable for the damage caused by data conversion, from the existing data to
GOT2000 series, GOT1000 series, or GOT-A900 series. 3
Before downloading converted project data to the GOT, be sure to check GT Designer3 setup and make
corrections if necessary.
SPECIFICATIONS
Note that any function that is not supported by the conversion destination GOT will not be converted.
(2) Converting a file with a name in other than English (Japanese, Chinese or other language)
The file cannot be converted when the file name is in other than English.Change the file name to English
before conversion.
(3) Converting a file including character strings in other than English (Japanese, Chinese or other
language)
4
The character strings cannot be converted correctly when the conversion source file includes character
GT CONVERTER2
SCREEN LAYOUT
strings in other than English.
Change the character strings to English with the drawing software before conversion.
Even the items described convertible in this Appendix may not be convertible depending on project setup.
If conversion failed in some items, descriptions of the error items are given in conversion log.
5
5.4 Checking Conversion Result
OPERATION METHODS
GT CONVERTER2
Appendix.1.1 Graphics Conversion specification
APPENDICES
App - 1
Appendix.1.2 Conversion specifications for sprites
Restrictions
The following describes the restrictions related to the conversion of sprites.
(1) Figures that cannot be changed as attributes for display
When converting the lamp display project data or the touch switch project data, the following basic figures are
converted as the library project data.
• LAMP 9 • LAMP 10 • LAMP 11
• LAMP 12 • LAMP 22 • SWITCH 34 ON
• SWITCH 34 OFF • SWITCH 45 ON • SWITCH 45 OFF
The project data for figures that are converted as the library data cannot change the attributes for display of GT
Designer3 ([Frame], [Lamp], [Switch], [Background], and [Pattern]).
To change attributes for display, change [Figure] for the display style to the basic figures.
Conversion specifications
The following indicates the conversion specifications of sprites.
Conversion
Item Remarks
applicability
: Convertible, : Inconvertible
App - 2
1
Appendix2 Conversion Specifications for GP-PRO/PB III
Series
OVERVIEW
This section explains conversion specifications of the GP-PRO/PB III series.
(The conversion specifications in this appendix indicate only those of the main items.)
2
POINT
CONFIGURATION
(1) Precautions for data conversion
GT Converter2 will not be liable for the damage caused by data conversion, from the existing data to
SYSTEM
GOT2000 series, GOT1000 series, or GOT-A900 series.
Before downloading converted project data to the GOT, be sure to check GT Designer3 setup and make
corrections if necessary.
Note that any function that is not supported by the conversion destination GOT will not be converted.
3
(2) Converting a file with a name in other than English (Japanese, Chinese or other language)
SPECIFICATIONS
The file cannot be converted when the file name is in other than English.
Change the file name to English before conversion.
(3) Converting a file including character strings in other than English (Japanese, Chinese or other
language)
The character strings cannot be converted correctly when the conversion source file includes character
strings in other than English.
4
Change the character strings to English with the drawing software before conversion.
GT CONVERTER2
SCREEN LAYOUT
The same conversion specifications of GT Converter2 are applied to all versions of the GP-PRO/PB III series.
Therefore, all the GP-PRO/PB III series versions can be used.
Even the items described convertible in this Appendix may not be convertible depending on project setup.
If conversion failed in some items, descriptions of the error items are given in conversion log. 5
OPERATION METHODS
5.4 Checking Conversion Result
GT CONVERTER2
Appendix.2.1 Conversion specifications of project data
APPENDICES
GOT1000 format is converted into a Language Switch device.
The device in GOT-A900 format is inconvertible.
(c) When "The target base screen of the L tag settings is converted to parts" is selected on Option, the graphic
data on the base screen read by the L-tag is converted into parts.
5.3.2 Conversion option settings
(d) Mark screens are inconvertible. Since parts of GT Designer3 function as same as Mark screen, recreate
the Mark screens with GT Designer3 parts after conversion.
App - 3
(e) After conversion, parts and figures completely lying off the top or left edge of the display area are displayed
as shown below.
• A part or figure lying off the top edge of the display area is displayed where its Y coordinate is changed
to 0.
• A part or figure lying off the left edge of the display area is displayed where its X coordinate is changed
to 0.
Before conversion, check if the parts and figures are outside the display area.
HINT
How to convert screen setup and screen number
To convert screen numbers on GOT, set a script or a ladder program to open the screen having the same number
as the initial screen number at a GOT startup.
(1) Setting example of opening the initial screen (screen No. 2) at a GOT startup using a script
GT Designer3 setting
• Base screen switch device GD100
(2) Program example for opening the initial screen (screen No. 2) at a GOT startup using a ladder program
GT Designer3 setting
• Base screen switching device D100
• System signal 2-1 D300
Program example
Writes screen No. 2 of initial
screen to base screen switch
device on rising edge of GOT
ready bit (bit 1 of system signal
2-1).
App - 4
1
Conversion specifications of alarm data
(1) Restrictions
The following describes the restrictions related to alarm data conversion.
OVERVIEW
(a) In the Bit Log Alarm setting and Word Log Alarm setting, only the log alarm selected for conversion is
converted.
5.3.2 Conversion option settings
2
(b) The background color of a text is not converted.
Therefore the text appears without background color.
CONFIGURATION
(c) Comment numbers are not shifted up at the time of conversion.
The positions having no numbers before conversion have no numbers after conversion.
SYSTEM
(2) Conversion specifications of alarm data
The following indicates the conversion specifications of alarm data.
Conversion 3
Alarm data item Conversion destination *1 Remarks
applicability
SPECIFICATIONS
• GOT2000
Comment Group, Alarm
Popup Display
Alarm Message • GOT1000
Basic Comment, Comment
Group/Advanced Alarm Popup
Display 4
• GOT2000
GT CONVERTER2
Comment Group, Alarm
SCREEN LAYOUT
Popup Display Refer to the following for the conversion destination comment
Alarm Summary setting
• GOT1000 No.
Basic Comment, Comment
Basic comment and comment group conversion
Group
• GOT2000
Comment Group, User Alarm
Observation
5
Bit Log Alarm setting
OPERATION METHODS
• GOT1000
Basic Comment/Common
GT CONVERTER2
Settings (Alarm History)
Basic Comment/Common
Word Log Alarm setting
Settings (Alarm History)
: Convertible, : Inconvertible
*1 Advanced Alarm Popup Display and Comment Group are convertible for GOT1000 series only.
APPENDICES
(1) Restrictions
The setting items related to a memory card are inconvertible.
App - 5
Conversion specifications of text tables
(1) Restrictions
The following describes the restrictions related to text table conversion.
(a) When text tables are converted into GOT2000 format or GOT1000 format, the text tables No. 1 to 10 will be
converted into basic comment and comment group, and text tables No. 11 and later will not be converted.
(b) When using Language Switch, convert a text table into GOT2000 format or GOT1000 format, and change
the object whose text will be displayed on GT Designer3 into an object compatible with Language Switch,
for example, Comment Display, Advanced User Alarm, Advanced System Alarm.
Language Switch cannot be executed without correcting the objects.
(c) When a text table is converted into GOT-A900 format, Language Switch will be disabled.
Refer to the above (b) for detail.
(d) When text tables are converted into GOT-A900 format, only the text table No. 1 is converted into the basic
comment, and the text tables No. 2 and later will not converted.
(e) Up to 512 characters of each text string in a text table will be converted and the 513th characters and later
will be deleted.
(f) The background color of a text will not be converted.
After conversion, the text appears without background color.
(g) Comment numbers will not shifted up at the time of conversion.
The positions having no numbers before conversion turns to as they are after conversion.
(2) Conversion specifications of text tables
The following indicates the conversion specifications of text tables.
Conversion
Text table item Conversion destination Remarks
applicability
: Convertible, : Inconvertible
App - 6
1
Conversion specifications of screen types
(1) Restrictions
The following describes the restrictions related to screen type conversion.
OVERVIEW
(a) Up to 12767 lines of strings on text screens are converted in order of screen numbers.
The 12768th lines and later will not be converted.
(b) The background color of a text on a text screen is inconvertible.
After conversion, the text appears without background color.
2
(c) On a text screen, one line is converted as one comment.
CONFIGURATION
(d) Comment numbers on a text screen will not be shifted up at the time of conversion.
(e) Text screens with multi-language setting are not converted.
SYSTEM
After conversion, set them as basic comments or comment groups on the GT Designer3.
(2) Conversion specifications of screen types
The following indicates the conversion specifications of screen types. 3
Conversion
Screen information item Conversion destination Remarks
SPECIFICATIONS
applicability
GT CONVERTER2
SCREEN LAYOUT
with GT Designer3 parts after conversion.
Trend Graph screen Window screen Window screen No.: 20001 to 28999
OPERATION METHODS
Image Library screen Parts Parts No.: 10001 to 18999
GT CONVERTER2
Video screen ------ ------
: Convertible, : Inconvertible
APPENDICES
App - 7
Basic comment and comment group conversion
The following shows the structure of alarm data, basic comment and comment group after converting from text table
and text screen.
18999 18999
20001
Text screen *1
32767
App - 8
Appendix.2.2 GP type 1
The following indicates the conversion specifications of the GP types.
OVERVIEW
Conversion source GP type Conversion destination GOT type
CONFIGURATION
GP2400 GT15-V A97 GOT
SYSTEM
GT15-Q
GP2300L A95 GOT
SPECIFICATIONS
GP2501 A97 GOT
GP2000
GP2401 A97 GOT
GP2301L
GT15-Q
A95 GOT 4
GP2501S GT15-V A97 GOT
GT CONVERTER2
SCREEN LAYOUT
GP2301HS A95 GOT
GT15-Q
GP2301HL GT27-V GT16-V A95 GOT
OPERATION METHODS
GP377R GT15-Q A95 GOT
GT CONVERTER2
GP570 A97 GOT
GT15-V
GP470*1 A960GOT
APPENDICES
GP571T A97 GOT
App - 9
Conversion source GP type Conversion destination GOT type
GLC200E *1 A960GOT
GT27-V GT16-V GT15-V
GLC300T A97 GOT
*1 When data is converted into GOT1000 format, a prompt appears to confirm screen size change to the 640 480 dots GT16-V/
GT15-V.
App - 10
Appendix.2.3 PLC type 1
The following indicates the conversion specifications of the PLC types.
When the conversion source PLC type is inconvertible, the project information screen shows that the PLC type is
OVERVIEW
inconvertible ( 5.2 Opening Conversion Source File [Procedure 3] ) , and then the whole project data will not be
converted.
Conversion source PLC type PLC type after conversion
GOT2000 format
2
Maker PLC type GOT-A900 format PLC type
GOT1000 format
CONFIGURATION
MELSEC-AnA(LINK) MELSEC-A
MELSEC-A(ETHER) MELSEC-A
SYSTEM
MELSEC-A(JPCN1) MELSEC-A
MELSEC-AnA(CPU) MELSEC-A
3
MELSEC-AnN(LINK) MELSEC-A
SPECIFICATIONS
MELSEC-AnN(CPU) MELSEC-A
MELSEC-QnA(LINK) MELSEC-QnA/Q
MELSEC-Q(ETHER) MELSEC-QnA/Q
GT CONVERTER2
SCREEN LAYOUT
MELSEC-FX(CPU) MELSEC-FX
MELSEC-FX2(LINK) MELSEC-FX
OPERATION METHODS
CC-Link type ------
GT CONVERTER2
FREQROL Series ------
SYSMAC-C 1:n
OMRON SYSMAC
communication
APPENDICES
THERMAC NEO Series ------
SYSMAC-CS1(ETHER) ------
App - 11
Conversion source PLC type PLC type after conversion
GOT2000 format
Maker PLC type GOT-A900 format PLC type
GOT1000 format
PANASONIC INDUSTRIAL
MEWNET-FP Series MATSUSHITA MEWNET-FP
DEVICES SUNX
YASKAWA CP9200SH/
MP900/CP9200SH Series
MP900 Series
YASKAWA CP9300MS
Memocon-SC Series
(MC compatible)
Inverter ------
FA-M3(ETHER) ------
Remoto IO ------
Memory Link
Microcomputer
Ethernet type
Digital Electronics Corporation
Memory Link
Microcomputer
SIO type
: Convertible, : Inconvertible
App - 12
Appendix.2.4 Screen information 1
Restrictions
OVERVIEW
The following describes the restrictions related to screen information conversion.
(1) Mark screens are inconvertible. Since parts of GT Designer3 function as same as Mark screen, recreate the
Mark screens with GT Designer3 parts after conversion.
(2) When Base screens are converted into parts by the setting on the Conversion setting screen ( 5.3.2 2
Conversion option settings),only graphic data is converted into parts.
CONFIGURATION
(3) When Image Library screens are converted, only graphic data is converted into parts.
SYSTEM
Restrictions 3
The following describes the restrictions related to graphic data conversion.
SPECIFICATIONS
(1) Blink settings are inconvertible.
(2) The graphic data that extends off the screen edge is inconvertible.
(3) Setup items, which have not been converted, are replaced by default settings of GT Designer3.
Conversion specifications
The following indicates the conversion specifications of graphic data.
4
When any inconvertible items are included in project data, only convertible items are converted.
GT CONVERTER2
SCREEN LAYOUT
Conversion
Graphic data item Conversion destination Remarks
applicability
OPERATION METHODS
Rectangle Rectangle / Polygon GOT1000 series only.
GT CONVERTER2
For converting rectangles into data available for GOT-A900
series, chamfered rectangles are converted into polygons.
APPENDICES
Arc scales are inconvertible.
Tick mark Scale
Linear scales are convertible.
Load Mark ------ Mark calls are inconvertible as well as Mark screens.
: Convertible, : Inconvertible
App - 13
Appendix.2.6 Tag information
Restrictions
The following describes the restrictions related to tag information conversion.
App - 14
1
Conversion specifications
The following indicates the conversion specifications of tag information.
When any inconvertible item is included in project data, only convertible items will be converted.
OVERVIEW
Conversion
Tag information item Conversion destination Remarks
applicability
• GOT2000 format
CONFIGURATION
• GOT2000 format
Simple Alarm Display
a-tag (Alarm Summary Display) ------
SYSTEM
• GOT1000 format
Alarm list
SPECIFICATIONS
E-tag (Extended N-tag Function) Numerical Display ------
GT CONVERTER2
SCREEN LAYOUT
J-tag (Moving Mark Display) ------ J-tag is inconvertible as well as Mark screen.
• GOT2000 format
Numerical Input, Character
Not converted when indirect setting is "Device type &
K-tag (Setting Input)*2 String Input
address".
• GOT1000 format
Numerical/ASCII Input 5
OPERATION METHODS
k-tag (Key Input) Key code switch ------
GT CONVERTER2
L-tag (Library display) Parts Display ------
APPENDICES
Numerical Display
Format) Cannot be converted to GOT-A900 format.
• GOT2000 format
Alarm Display (User)
Q-tag (Alarm Summary Display) ------
• GOT1000 format
Alarm history
• GOT2000 format
Character String Display
S-tag (String Display) ------
• GOT1000 format
ASCII Display
: Convertible, : Inconvertible
(Continued to next page)
App - 15
Conversion
Tag information item Conversion destination Remarks
applicability
W-tag (Write to Device) Status Observation: Screen Not converted when action setting is bit inversion.
: Convertible, : Inconvertible
*1 When the relative setting is specified for G-tag and g-tag, the maximum and minmum values in the input range are converted into
the upper and lower limits.
*2 Data in the alarm range set for K-tag are converted into data in the display range of the numerical input. Data outside the alarm
range are converted into data in the input range of the numerical input.
*3 When a word address of the display start line is set for X-tag, the address is converted into data of a monitor device.
App - 16
Appendix.2.7 Parts information 1
Restrictions
OVERVIEW
The following describes the restrictions related to parts information conversion.
CONFIGURATION
(4) Graphic data included in the parts will be converted into graphics.
(5) Name plate characters of switch, lamp and message display are converted as name plate of conversion
destination object. (Display position is center.)
SYSTEM
Conversion specifications
The following indicates the conversion specifications of parts information. 3
When any inconvertible items are included in project data, only convertible items are converted.
SPECIFICATIONS
Conversion
Parts information item Conversion destination Remarks
applicability
GT CONVERTER2
SCREEN LAYOUT
Lamp*3 Lamp display ------
OPERATION METHODS
Tank Graph*1 Level display ------
GT CONVERTER2
Meter Graph*1 Panelmeter ------
• GOT2000 format
Numerical Input, Character
Keypad Input Display*2 String Input ------
• GOT1000 format
APPENDICES
Numerical/ASCII Input
: Convertible, : Inconvertible
(Continued to next page)
App - 17
Conversion
Parts information item Conversion destination Remarks
applicability
: Convertible, : Inconvertible
*1 When the relative setting is specified for bar graphs, pie graphs, half pie graphs, tank graphs, and meter graphs, the maximum
and minmum values in the input range are converted into the upper and lower limits.
*2 Data in the alarm range set for the keypad input display are converted into data in the display range of the numerical input. Data
outside the alarm range are converted into data in the input range of the numerical input.
*3 When a name plate which is referring to a text table is converted to GOT2000 format or GOT1000 format, the name plate is
converted to a Comment Group name plate.
Appendix.2.8 D-Script
Restrictions
The following describes the restrictions related to D-Script conversion.
(1) When a script includes any inconvertible items other than a trigger, that script will not be converted.
(2) Trigger expressions, "Detect true (nonzero)" and "Detect false (zero)" will be converted to [Ordinary] of trigger
type.
HINT
How to convert functions similar to expressions, true (nonzero) and false (zero)
The script to which the following control statement is added to the head part after being converted to GT Designer3
can be executed under the same condition as D-Script.
• When "Detect true (nonzero)" is used in D-Script
*1 The above <Condition> is an expression that is considered to be true at the trigger conditions of "Detect true (nonzero)"
• When "Detect false (zero)" is used in D-Script
*2 The above <Condition> is an expression that is considered to be true at the trigger conditions of "Detect false (zero)"
App - 18
1
Conversion specifications of script settings
The following indicates the conversion specifications of script settings.
Conversion
OVERVIEW
Script setting item Conversion destination Remarks
applicability
ID ------ ------
CONFIGURATION
Trigger By editing the script on GT Designer3 after conversion,
Condition Trigger type (Ordinary) similar functions can be reproduced.
SYSTEM
Restrictions
SPECIFICATIONS
Execution Script file ------
GT CONVERTER2
SCREEN LAYOUT
Conversion specifications of variables
The following indicates the conversion specifications of variables.
Conversion
Variable Conversion destination Remarks
applicability
OPERATION METHODS
Hex (Hexadecimal) ------ ------
GT CONVERTER2
Oct (Octal) ------ ------
: Convertible, : Inconvertible
APPENDICES
Temporary work address Temporary device area ------
: Convertible, : Inconvertible
App - 19
Conversion specifications of commands
The following indicates the conversion specifications of commands.
Conversion
Command Conversion destination Remarks
applicability
Memory Copy
bmov ------
(memcpy/_memcpy_EX)
Memory Set
fmov ------
(memset/_memset_EX)
Receive (IO_READ/
------ ------
_IO_READ_EX)
Send (IO_WRITE/
------ ------
_IO_WRITE_EX)
: Convertible, : Inconvertible
App - 20
1
Conversion specifications of comparisons
The following indicates the conversion specifications of comparisons.
Conversion
OVERVIEW
Comparison Conversion destination Remarks
applicability
or ------
2
not ! ------
CONFIGURATION
< < ------
SYSTEM
<> != ------
SPECIFICATIONS
== == ------
: Convertible, : Inconvertible
GT CONVERTER2
SCREEN LAYOUT
+ + ------
- - ------
% % ------
* * ------
5
/ / ------
OPERATION METHODS
= = ------
GT CONVERTER2
<< << ------
------
^ ^ ------
APPENDICES
~ ~ ------
: Convertible, : Inconvertible
App - 21
Conversion specifications of descriptive expressions
The following indicates the conversion specifications of descriptive expressions.
Conversion
Descriptive expressions Conversion destination Remarks
applicability
if(Condition)
if(Condition)
{
{
Processing ------
Processing;
}
}
endif
if(Condition)
if(Condition)
{
{
Processing 1
Processing 1;
}
}
else ------
else
{
{
Processing 2
Processing 2;
}
}
endif
loop(Temporary) while(Temporary)
{ { When Write value is set to a device other than Temporary
Processing Processing; in a loop statement, the loop statement will not be
} Temporary= Temporary - 1; converted.
endloop }
: Convertible, : Inconvertible
Conversion source
Processing 1 Processing A
Processing 2 Processing B
Processing C
Call Function1
Processing 3
Converted by GT Conveter2
After conversion
GOT script
Processing 1
Processing 2
Processing 3
App - 22
Appendix.2.9 LS area 1
The following describes the conversion specifications of LS areas.
OVERVIEW
Restrictions
The following describes the restrictions related to LS area conversion.
(1) Devices from LS0 to LS2031 and LS2096 to LS8191 will be converted into GOT data registers GD of the same
device numbers as the LS area addresses. For example, LS4000 is converted to GD4000.
2
Since the function of LS area will not be replaced by the GOT data register GD, that is user area, reallocate the
CONFIGURATION
devices with GT Designer3 if necessary.
(2) When any of devices from LS0 to LS63 is converted into GOT-A900 format, reallocate the device with GT
SYSTEM
Designer3 since those devices cannot be used.
(3) Since devices from LS0 to LS19, system data area, are converted into GOT data registers GD, that is user area,
the functions become unavailable after conversion.
3
Conversion specifications of LS areas
SPECIFICATIONS
The following indicates the conversion specifications of LS areas.
(1) The LS area described in the D script is also converted like the LS area set to the object.
Conversion source LS Conversion destination
Description Remarks
area device
GT CONVERTER2
SCREEN LAYOUT
LS2032 GS0 Common relay information Appendix 2.9 Conversion specifications
of LS2032
OPERATION METHODS
LS2038 GS10 Tag scan counter ------
GT CONVERTER2
Converted into device having the same number as
LS2096 to LS8191 GD2096 to GD8191 Internal device
the LS area address.
APPENDICES
App - 23
Conversion specifications of LS2032
The following indicates the conversion specifications of LS2032.
Conversion destination
Bit Description Remarks
device
Turns ON only when a communication Converts into the status in which no device has
2 ------
error occurs. been set.
Turns ON when the backup SRAM data is Converts into the status in which no device has
6 ------
cleared. been set.
10 Transfer completion bit address Converts into the status in which no device has
------
been set.
Keeps ON while filing data is being
11 transferred from SRAM to LS area by the
file item display.
App - 24
REVISIONS
* The manual number is given on the bottom left of the back cover.
Nov., 2012 SH(NA)-080862ENG-E • The information site on the Internet is changed to the Mitsubishi Electric Factory Automation
Global Website.
• SAFETY PRECAUTIONS changed
Jun., 2014 SH(NA)-080862ENG-H • Revisions have been made because production of the CD-ROM version of GT Works3 was
discontinued.
This manual confers no industrial property rights or any rights of any other kind, nor does it confer any patent licenses. Mitsubishi Electric
Corporation cannot be held responsible for any problems involving industrial property rights which may occur as a result of using the
contents noted in this manual.
REVISIONS - 1
GOT is a registered trademark of Mitsubishi Electric Corporation.
Microsoft, Windows, Windows NT, Windows Server, Windows Vista, and Windows 7 are registered trademarks or trademarks
of Microsoft Corporation in the United States and other countries.
Adobe and Adobe Reader are registered trademarks of Adobe Systems Incorporated.
Intel, Intel Core, Pentium, and Celeron are trademarks or registered trademarks of Intel Corporation in the United States
and other countries.
Ethernet is a registered trademark of Xerox Corporation in the United States.
MODBUS is a trademark of Schneider Electric SA.
VNC is a registered trademark of RealVNC Ltd. in the United States and other countries.
Other company and product names herein are either trademarks or registered trademarks of their respective owners.
SH(NA)-080862ENG-J
Integrated FA Software
GT Converter2 Version3
Operating Manual for GT Works3
MODEL SW3-GTCONV2-O-E
MODEL 1D7MB2
CODE
SH(NA)-080862ENG-J(1605)MEE
HEAD OFFICE : TOKYO BUILDING, 2-7-3 MARUNOUCHI, CHIYODA-KU, TOKYO 100-8310, JAPAN
NAGOYA WORKS : 1-14 , YADA-MINAMI 5-CHOME , HIGASHI-KU, NAGOYA , JAPAN
When exported from Japan, this manual does not require application to the
Ministry of Economy, Trade and Industry for service transaction permission.