Professional Documents
Culture Documents
(4) Click Next after entering the user information and other (4) Read through and understand the License Agreement and
2. Installation of“KEW Report” supplementary information.
(For Windows 8 / 10)
click“I accept….”, and then click Next.
(For Windows 7) (1) Always check the followings before installing“KEW
Installation Manual (1) Always check the followings before installing“KEW
(5) Confirm the information on installation, and then click
Install to start the installation process.
Report”.
・ To prepare your system for installation, please close
Report”. all open programs.
・To prepare your system for installation, please close If a message requiring restarting your computer is ・ Be sure NOT to connect the instrument to a PC until
all open programs. displayed, click Yes and restar t your computer. the installation completes.
・Be sure NOT to connect the instrument to a PC until Installation process will then restart. ・ Installation shall be done with Administrator right.
the installation completes.
・Installation shall be done with Administrator right. Restarting your computer is essential to install the (2) Insert the supplied CD-ROM containing“KEW Report”in
application properly. your PC’s CD-ROM drive. Then the following pop-up will
(2) Insert the supplied CD-ROM containing“KEW Report”in appear at the upper right on the screen. Left-click on this
your PC’s CD-ROM drive. Click Run install.exe when (6) Click Finish when“InstallShield Wizard Complete”dialog box.
AutoPlay window pops up. box appears. When the installation wizard completes,
This manual contains instructions how to install the special
subsequent installation begins automatically. Please refer
s o f t w a r e“ K E W R e p o r t ”s u p p l i e d w i t h K E W 6 2 0 5, If the installer does not run automatically, click the CD
MODEL8212USB and 8212-RS232C. to 3. USB driver installation.
icon to run the“install.exe”file. If the User Account
1. Introduction Control dialog box appears, click Yes.
(5) Click Next after entering the user information and other
● Interface (3) Read through and understand the License Agreement and (3) Click Run install.exe when the box as shown below supplementary information, and click Next.
This instrument is equipped with a USB interface. click“ I accept….”, and then click Next. appears.
Communication method: USB Ver1.1 If User Account Control dialog box appears, click Yes. (6) Confirm the information on installation, and then click
The internal data of the instrument can be transferred Install to start installation.
to a PC via USB communication.
● System Requirements
・OS (Operation System)
For the supported OS, check the label on the CD case
or visit our website.
・Display
1024×768 dots, 65536 colors or more
・HDD (Hard-disk space required)
100 Mbyte or more
●Trademark How to un-install“ KEW Report”:
・W indows® is a registered trademark of Microsoft in Open the Control panel, click Add/ Remove Programs
the United States. and select“ KEW Report”.
The latest software is available for download from our
website.
www.kew-ltd.co.jp If neither (2) nor (3) appears, click the CD icon and run
“install.exe”file.
(7) Click Finish when“InstallShield Wizard Complete”dialog (3) If the following Security Warning message appears, click (4) Installation completes when the following window
box appears. When the installation wizard completes,
3. USB Driver Installation Install. appears.
(For Windows 8 / 10)
subsequent installation begins automatically. Please refer (For Windows 7) Click Finish. (1) When KEW Report has been successfully installed in your
to 3. USB driver installation. computer, the following dialog box appears to start
(1) When KEW Report has been successfully installed in your installing the USB driver.
computer, the following dialog box appears to start Click Next.
installing the USB driver.
Click Next.
Click Finish. (For Windows 7) (1) Right-click Start button and then Device Manager.
(2) Click Ports (COM & LPT) to see the COM port number *If Advanced… is gray and you cannot open it:
assigned for the instrument.
5. Changing COM Port No. Click General tab and then Change settings.
6. Starting KEW Report
(For Windows 7/ 8/ 10) Star t“KEW Repor t ”by; 1) clicking the icon for“KEW
Report”on your desktop, or 2) clicking Start -> Program
(1) Follow the procedures described in 4. Checking COM
-> KEW -> KEW Report.
Port No. and perform steps (1) to (3).
(1) COM Port setting
(2) After performing step (3), select the displayed instrument
Click Communicat ion -> COM Por t on the Main
name (COMx) and click Properties.
Window of“ KEW Report”, and select the pre-set COM
Port number.
(2) Download
(4) Click and select a number (from COM1 to COM32) on the Click Communication -> Download on the Main Window
COM Port Number: box, and then click OK. of “KEW Report”. Then the following window appears.
Click Exit or“x”box at the upper right of the window to
close the program.
(3) If the assigned number is out of COM1 to COM32, follow (3) Click Port Settings tab, and then click Advanced….
the instructions described in 5. Changing COM Port
No. and change the number accordingly.