Professional Documents
Culture Documents
Catalog 2013
English
CONTENT
INTRODUCTION ............................................ 3
ELECTROSURGERY..................................... 26-29
Servotome ..................................... 28
Dear colleagues,
Piezo-ultrasonic surgery offers atraumatic surgery (something laser once promised) a never
before seen ease and precision in surgical procedures, and an almost blood-free operative
field. Some additional benefits include faster healing with significantly less swelling, pain and
complications.
02 > 03
healing and faster healing.
Like all new technology, ultrasonic surgery requires thorough and comprehensive training. The
procedures for piezo-ultrasonic surgery differ in principle from the procedures with rotary
instruments and should not be used in a similar fashion. It is therefore recommended to
read up on the physical principles of ultrasound and all its effects (harmonic and modulated
vibrations, cavitation effect) before using the device for the first time and to complete a
certified piezo-ultrasonic surgery course.
With that in mind, I wish you much success in the new age of piezo-ultrasonic surgery!
ULTRASONICS
04 > 05
Piezotome Solo Piezotome 2 Implant Center 2
Newtron® Technology:
Unit, handpiece and tips are one
o Efficient and optimal vibrations,
o Extremely regular motion, Cru is e C o n tr o l®
06 > 07 ULTRASONICS
SATELEC® surgical pumps are Most power on the market, Numerous SATELEC®
well known for their: 6 ceramic rings Piezotome® surgical tips:
o Easy insertion of the o Effortless cut Bone surgery, Sinus Lift,
irrigation line o Boosted handpiece IntraLift®, Crest Splitting,
o Solidity o No overheating Extraction, Crown
o Quiet operation o Excellent yield Extension, etc.
The Essential
Piezotome® Solo, the best of SATELEC® technology in a compact device.
It integrates the most powerful, reliable and safe components dedicated to ultrasonic
pre-implant surgery.
Intuitive
The Piezotome® Solo is incredibly easy to use thanks to its
straightforward settings.
A complete offering
Unit delivered with handpiece and Essential kit.
Multifunction
footswitch
08 > 09 ULTRASONICS
Power Precision and safety for fast surgeries limiting soft tissue damage.
Piezotome® Mode
Simplicity Only essential features for ease of use.
Piezotome Solo Piezotome 2 Implant Center 2
10 > 11 ULTRASONICS
2 modes available
o Piezotome® o Newtron®
Pre-implant bone surgery Conventional tooth treatment
Piezotome Solo Piezotome 2 Implant Center 2
Customizable Stability
o Four pre-set easily customizable o Perfect balance between torque and speed for unmatched stability.
programs, o Maximum torque: 6Ncm up to 24,000Rpm
o Intuitive settings can be quickly adjusted o Maximum torque at instrument end (20:1): 120Ncm
during surgery. o Motor speed: 100 - 40,000Rpm
Torque
N.cm
6
I-Surge
5,5 Competitor A
Competitor B
PiezoTouchTM: progressive power 5
100 200 300 5 000 10 000 15 000 20 000 25 000 30 000 35 000 40 000
12 > 13 ULTRASONICS
3 modes available
o I-SURGE™ o Piezotome® o Newtron®
Implantology motor Pre-implant bone surgery Conventional tooth treatment
Piezotome Solo Piezotome 2 Implant Center 2
MANY
EXCLUSIV
E
Crown Extension TIPS
Incomparable precision and
accessibility.
CE Kit (Ref. F87554)
ACCESSORIES
Piezotome® Packs
Including: one sterilization box, one Piezotome LED
handpiece, one Kit, one dynamometric wrench.
Essential Pack (F87529)
Bone Surgery (BS) Pack (F87500)
Sinus Lift (SL) Pack (F87510)
IntraLift® Pack (F87530)
Crest Splitting (CS) Pack (F87560)
Extraction Pack (F87540)
Crown Extension (CE) Pack (F87550)
Piezotome Pack (F87523) – without any kit
14 > 15 ULTRASONICS
Including: one sterilization box, one Newtron® LED
handpiece, one Newtron® Perio Kit (H1, H2L, H2R, H3,
H4L, H4R), one dynamometric wrench (F87520).
Piezo ultrasonic surgery unit Piezo ultrasonic surgery unit Piezo ultrasonic surgery Implantology motor
Unit + conventional treatment + Piezo ultrasonic surgery
features (Perio, endo, etc) unit + conventional treatment
(Perio, endo, etc) unit
Unit
dimensions 378 x 136 x 306mm ; 378 x 136 x 306mm ; 472.9 x 149.5 x 339.9mm ; 472.9 x 149.5 x 339.9mm ;
(W x H x D 3.7Kg 3.7Kg 5Kg 5Kg
and weight)
Footswitch
dimensions 173 x 140 x 176mm 173 x 140 x 176mm 311 x 181 x 209mm 311 x 181 x 209mm
(W x H x D 1Kg 1Kg 3.5Kg 3.5Kg
and weight)
PIEZOTOM Be part of our Piezotome® training sessions and workshops. Numerous trainings
E are available in collaboration with dental associations. Check Piezotome.com
TRAINING
S website agenda and contact ACTEON® worldwide.
SUMMARY
Maximum Maximum
Fine Irrigation Fine Irrigation
Tips recommended setting* ml/min Tips recommended setting* ml/min
modes modes
16 > 17 ULTRASONICS
Mandible Maxillary 1 to 3
1 to 3
TKW4 D2 100
3
TKW5 D3 30-40
1
*Not applicable to PIEZOTOME SOLO (LED).
Piezo ultrasonic surgery books LATERAL SINUS LIFT
Practical Osseous Surgery in Periodontics and Implant The Effect of Piezoelectric Use on Open Sinus Lift
Dentistry, S. Dibart, J-P. Dibart, Wiley-Blackwell, 2011. Perforation: A Retrospective Evaluation of 56 Consecutively
Extraction, IntraLift® (sinus lift by the crestal approach) Treated Cases From Private Practices, N. J. Toscano,
and the Piezocision™ techniques with Piezotome D. Holtzclaw, and P. S. Rosen, Journal of Periodontology,
ultrasonic surgical units are developed. Vol. 81, No. 1, Pages 167-171, January 2010.
“Zero perforation of the Schneiderian membrane
occurred during the piezoelectric preparation of the
Clinical Success in Bone Surgery with Ultrasonic Devices, lateral antrostomies, whereas two perforations were
M-G. Poblete-Michel, J-F. Michel, Foreword by Ray C. noted during subsequent membrane elevations using
Williams, Quintessence International, 2009. hand instrumentation. In both instances, membrane
“The piezoelectric surgery accordingly offers comfort, perforations were associated with sinus septa. The
safety, and precision to the surgeon during delicate overall sinus perforation rate was 3.6%”.
interventions”.
INTRALIFT®
Clinical articles Biological Principles and Physiology of Bone Regeneration
under the Schneiderian Membrane after Sinus Lift Surgery:
Increased Intraosseous Temperature Caused by Ultrasonic A Radiological Study in 14 Patients Treated with the
Devices During Bone Surgery and the Influences of Working Transcrestal Hydrodynamic Ultrasonic Cavitational Sinus
Pressure and Cooling Irrigation, F. Birkenfeld, M. E. Lift (Intralift), A. Troedhan, A. Kurrek, M. Wainwright,
Becker, S. Harder, R. Lucius, M. Kern, IJOMI, Vol. 27 , International Journal of Dentistry ; 2012:576238, 2012.
Issue 6, November/December 2012. “All 14 tHUCSL Intralift Sinus lift procedures were
“Harmless intraosseous temperature development was conducted without perforation of the sinus membrane,
identified for working pressures of 1.5N and 2.0N with and no postsurgical complications suspicious of sinus-
cooling irrigations of 30, 60, and 90ml/min and for 3.0N membrane perforations occurred. It proves the key
at 90ml/min. A working pressure above 3.0N did not role of the sinus membrane as the main carrier of bone
result in improved cutting performance”. reformation after Sinus Lift procedures as multiple
experimental studies suggested the importance of
Analysis of Heating Induced by Piezoultrasonic Devices minimal invasive and rupture free sinus lift procedures is
During Bone Surgery, M-G. Poblete-Michel, E. Tuffreau, underlined and does not depend on the type of grafting
J-F Michel, IJOMI, Vol. 2, No. 8, pp 37-51, October 2010. material used”.
“Piezosurgery® incision shows variable heating, ≥ 10°C
compared to the Piezotome®. The quantity of irrigation Rupture length of the sinus membrane after 1.2mm
must be at least 30ml/min”. puncture and surgical sinus elevation: an experimental
animal cadaver study, S. Jank, A. Kurrek, M. Wainwright,
Performance of Ultrasonic Devices for Bone Surgery and VE Bek, A. Troedhan, Oral Surgery Oral Medecine Oral
Associated Intraosseous Temperature Development, S. Pathology Oral Radiology and Endodontology ; 112(5):568-
Harder, C. Mehl, IJOMI, Vol. 24, No. 3, 2009. 72 ; Nov 2011.
“Acteon® & Mectron™ showed a significantly higher “The Intralift® (HUCSL) technique yielded the lowest
cutting performance, whereas Acteon® produced the increase of rupture length compared with balloon-
least increase of intra-osseous temperature”. assisted technique and Summers lift. The technique
therefore shows the lowest risk of a growing rupture of
the sinus membrane in case of an iatrogenic puncture
during preparation of the transcrestal approach”.
BIBLIOGRAPHY
Hydrodynamic Ultrasonic Sinus Floor Elevation - An PIEZOCISION®
Experimental Study in Sheep, A. Troedhan, A. Kurrek,
M. Wainwright, Journal of Oral Maxillofacial Surgery, Rapid treatment of class II malocclusion with Piezocision® :
68:1125-1130, 2010. Two case reports, S. Dibart, JD. Sebaoun, L. Montesani,
“To detach the sinus membrane pneumatically (Balloon) International Journal of Perio & Restorative Dentistry,
around 29.54 millibars was required against 19.8 millibars Vol. 30, N°5, Oct 2010.
for the hydraulic technique (IntraLift™) with an average “The combination of buccal interproximal microincisions
lifted volume of 3.92ml. With Piezotome®, no rupture of and localized piezoelectric corticotomies is able to create
the sinus membrane of sheep heads occurred”. a significant amount of demineralization around teeth in
the areas of tooth movement, making this a very attractive
The IntraLift™: A new minimal invasive ultrasonic alternative to conventional and more aggressive techniques.
technique for sinus grafting procedures, M. Wainwright, It offers advantages that should lead to greater acceptance
A. Troedhan, A. Kurrek, Implants magazine, Dental in the dental and patient communities”.
Tribune International, Vol.8, Issue 3, 2007.
“The IntraLift is an alternative to conventional sinus Acceleration of orthodontic tooth movement following
18 > 19 ULTRASONICS
grafting techniques with dramatically reduced trauma selective alveolar decortication: biological rationale and
and high patient acceptance. New trabecular bone outcome of an innovative tissue engineering technique,
formation was partially visible only after 6 weeks, and JD. Sebaoun, J. Surmenian, D. J. Ferguson, S. Dibart,
in 98%, the treated patients didn’t use any analgetics”. International Orthodontics, 6:235-249, 2008.
“Piezocision® technique to treat arch crowding and borderline
skeletal problems. The use of Piezotome® creates a significant
EXTRACTION ease in making the cuts in areas of severe crowding”.
Comparative evaluation of surgical outcome after removal
of impacted mandibular third molars using a Piezotome® or CREST SPLITTING
a conventional handpiece: a prospective study, M. Goyal,
K. Marya, A. Jhamb, S. Chawla, PR. Sonoo, V. Singh, Vertical alveolar crest split and widening – an experimental
A. Aggarwal, British Journal of Oral and Maxillofacial study on cow ribs, ultrasonic tool development and test
Surgery, 50(6):556-61. September 2012. on human cadaver heads, A. Troedhan, A. Kurrek, M.
“When we compared the overall outcome in the two Wainwright, Surgical Techniques Development, 2:e10 ;
groups, we found significantly less pain, trismus, and 2012.
facial swelling and a better perception of the quality of “The results of this study suggest that, with the use of
life by the patients after third molar extraction using ultrasonic surgical devices, the indication for vertical
the Piezotome®”. crest-splitting can be narrowed down to a crest width
of 2mm and even less and that it can be performed
Ultrasonic Piezotome surgery: is it a benefit for our flapless, thus leaving the physiological bone-periosteum
patients and does it extend surgery time? A retrospective system fully intact”.
comparative study on the removal of 100 impacted
mandibular 3rd molar, A. Troedhan, A. Kurrek, Reconstruction of Posterior Mandibular Alveolar Ridge
M. Wainwright, Open Journal of Stomatology, 2011. Deficiencies With the Piezoelectric Hinge–Assisted Ridge
“Piezotome-surgery is superior in atraumaticity and soft- Split Technique: A Retrospective Observational Report,
tissue safety compared to traditional procedures with D. J. Holtzclaw, N. J. Toscano, and P. S. Rosen, Journal
burs and grants the patients significantly less post surgical of Periodontology, Vol. 81, No. 11, Pages 1580-1586 , DOI
pain and swelling. No lesions of the mandible nerve were 10.1902/jop.2010.100093, 2010.
detected with Piezotome surgery whereas surgery with “This retrospective observational report demonstrates
rotary instruments resulted in 16% hypesthesia at least that the piezoelectric hinge– assisted ridge split procedure
up to one week. can achieve substantial gains in horizontal ridge width
Ultrasonic surgical devices time consumption reduces of the edentulous posterior mandible without associated
to normal values after a learning curve showing no morbidity”.
significant time difference to procedures with rotary
instruments”.
THE ANSWER TO YOUR
REQUIREMENTS BY SATELEC®
A highly-engineered drive unit for dental surgery applications!
This powerful unit has reliable electronic speed and torque control with an integrated coolant pump.
All operations during the implantology procedure can be accomplished with complete safety
and extreme accuracy.
I-Surge
IMPLANTOLOGY
20 > 21
MOTORS
I-Surge
1 unit, 2 configurations
o I-Surge with Implant Ster micromotor and a
multifunctional footswitch
o I-Surge with Implant micromotor and single
function footswitch
Built to last
o Sleek and silent peristaltic pump with a very ergonomic
magnetic opening and closing system.
- Magnetic system makes irrigation pump stable and
quiet.
- Autoclavable or sterile single use irrigation lines
available. (see page 15)
- Intuitive cassette insertion and irrigation line setting.
IMPLANTOLOGY MOTORS
22 > 23
+
Implant micromotor
Micromotor
Torque 54Ncm
Fits all contra-angles! All SATELEC® motors have an E-type – ISO 3964 connection
Compatibility
7 contra-angles ratios available (1:1, 16:1, 20:1, 24:1, 32:1, 64:1, 80:1)
IMPLANTOLOGY MOTORS
Implant Ster micromotor
Micromotor
24 > 25
Torque 72Ncm
Fits all contra-angles! All SATELEC® motors have an E-type – ISO 3964 connection
Compatibility
7 contra-angles ratios available (1:1, 16:1, 20:1, 24:1, 32:1, 64:1, 80:1)
D’Arsonval proved that high frequency currents above 100kHz have no harmful effects on humans. They will only
have a thermal action. The section action is determined by the speed of heat produced which will induce cell
vaporization. The coagulation action generates an electric discontinuous wave which will create less heat.
The current quality plays an important role on the cutting and coagulation effect. With more than 30 years of
high frequency experience, SATELEC® develops efficient, secure, with unique features unit.
0 T
-V
ELECTROSURGERY
26 > 27
Servotome
Certification
Controlled power for all
Electrosurgical units, in compliance with new standards
and dental environment constraints, now require a electrosurgical applications
conductive plate for a current return path, placed in
direct contact with the patient’s skin for more security. o Incisions/Excisions
o Frenectomy
SATELEC®’s choice for a bracelet system is the best o Gingivoplasty
compromise for safety and convenience: o Coagulation
o Easy to install to enhance patient acceptance, o Abscess incision
o Conductive (in direct contact with the patient’s skin), o Exposure of impacted/retained teeth
o Easily disinfected, o Gingivectomy
o Adjusted to a contact region with a low resistance, o Etc.
o Perfect size to avoid concentration of heat.
30 watts is enough
Decrease Wattage for greater efficiency. This bracelet
can concentrate the current at a given point offering:
o Controlled power,
o More reliable and reproducible setting,
o High performances and better yield,
o Less energy loss.
28 > 29 ELECTROSURGERY
SATELEC®, Equipment division of the ACTEON® group, is the world leader in piezoelectric generators and also
offers a complete range of electronic equipment for implantology including piezo ultrasonic surgery units,
radiology, electrosurgery units, autoclaves, etc.
PIERRE ROLLAND®, Pharmaceutical division of the ACTEON® group and manufacturer of Expasyl® and Riskontrol®,
offers a full selection of dental consumables such as anesthetics, hygiene, hemostasis, filling materials, etc.
SOPRO®, Imaging division of the ACTEON® group, already recognized worldwide as the leader in intra-
oral cameras, also develops innovative digital radiology systems. The medical division of SOPRO® designs,
manufactures and sells a comprehensive range of surgical endoscopy equipment.
White Fox Pierre Rolland
RELATED
30 > 31
PRODUCTS
White Fox Pierre Rolland
Other
CBCT
Medical
Scanner
Ø 60mm x 60mm Ø 80mm x 80mm Ø 120mm x 80mm Ø 150mm x 130mm Ø 200mm x 170mm
(optional)
White Fox Pierre Rolland
BIOSTITE® PAROGUIDE®
Alloplastic material for bone regeneration Alloplastic material for bone regeneration
Applications Applications
BIOSTITE® is used in dental and oromaxillofacial surgery. Some PAROGUIDE® is a membrane to maintain the barrier effect.
uses include filling extraction defects to create an implant This barrier prevents connective tissue and epithelial
bed and for defects following surgical removal of retained cells growing into the bony tissue during the regeneration
teeth, after extraction or to close root tip resections. phase. Its primary application is periodontology.
Properties Properties
The off-white BIOSTITE® can be easily shaped. Easy positioning PAROGUIDE® is an absorbable membrane for guided tissue
and simple processing enables rapid filling of defects. regeneration. It is impermeable and of average strength.
Properties
For unimpaired wound healing, blood clot stabilization
must be achieved. The dimensional stability of the
collagen cylinder ensures that blood completely penetrates
the material which stabilizes the blood clot. It resorbs
completely.
Products may not be available in all markets, please contact ACTEON® for availability.
A ONE-STOP SHOP
Properties
o Thixotropic properties
o Good adhesion to the membrane – without compression
o Aluminum chloride increases the mechanical hemostatic
effect
o Easy to see and to remove (air/water spray)
o Pain-free method, if HEMOSTASYL™ is applied to healthy
periodontium
o Time of application: 2 minutes
- RCS Paris B 337 934 483 - 028764
Non contractual document - Ref. D27111-V2 (01/2013) - Copyright © 2013 SATELEC. All rights reserved. No information or part of this document may be reproduced or transmitted in any form or by any means without the prior permission of SATELEC.
Find all our products
on piezotome.com
SATELEC®
These medical devices are manufactured according to current regulations and standards (IEC 60601-1) and according to certified
ISO 13485 Quality Management System.
PIERRE ROLLAND®
Medical devices presented in this catalog are health products stamped with the CE marking, according to this regulation. Read carefully
the instructions in the leaflet supplied with the product. Medical Devices marketed by PIERRE ROLLAND® are not reimbursed by health
insurance organizations.
Creation date: January 2013.
Updates are available on the site: www.acteongroup.com
SATELEC • A Company of ACTEON Group • 17 av. Gustave Eiffel • BP 30216 • 33708 MERIGNAC cedex • FRANCE
Tel + 33 (0) 556 340 607 • Fax + 33 (0) 556 349 292 • E-mail: satelec@acteongroup.com • www.acteongroup.com