Professional Documents
Culture Documents
c) ON 3 2 1 OFF – The programmer uses 2-ON/OFF d) Press the button and repeat the above
periods per day. This operates the first ON/OFF time process to review each on the ON/OFF times for
and the third ON/OFF time, ignoring the second the CENTRAL HEATING channel
ON/OFF time.
5) Changing the programme times g) Pressing the “OK” button again will cancel the
HOLIDAY MODE and the programmer will return to
a) Move the selection switch to “PROG SET” the programme originally programmed.
8) BOOST Function
b) The LCD will flash, enabling the user to a) The BOOST function enables the relevant
programme the HOT WATER channel. channel, if switched ON, to be extended by 1, 2
or 3 hours, depending on the number of times the
c) Press the “+” or “-” buttons to adjust the “P1” ON relevant “BOOST” button is pressed.
time. When the correct time is displayed, press the
“OK” button. b) The BOOST function enables the relevant
channel, if switched OFF, to be switched ON for
d) Press the “+” or “-” buttons to adjust the “P1” OFF 1, 2 or 3 hours, depending on the number of
time. When the correct time is displayed, press the times the relevant “BOOST” button is pressed.
“OK” button.
User Instruction Leaflet: LE/0497/0004/Nov2011/Rev00 Page 2 of 3
c) Press the button to “BOOST” the HOT c) Hold down both the “+” and “-” buttons at the
WATER channel. same time for 5 seconds to enter the selection
mode.
d) Press the button to “BOOST” the
CENTRAL HEATING channel. d) Press either the “+” and “-” buttons to set the
Frost Protection set point (between 5~20°C).
9) ADVANCE Function
e) Press the “OK” button to activate.
a) The ADVANCE function enables the user to
reverse the status of the relevant channel. f) Note: In order to save battery power the frost
protection function is only active when the unit is
b) If the programme calls for the relevant channel to connected to mains power. The function can still
be ON, pressing the “ADVANCE” button will be set-up under battery power.
switch the relevant channel OFF. Pressing the
“ADVANCE” button again, of the relevant 12) Setting the room temperature
channe,l will switch the relevant channel ON (if option activated during installation)
again.
a) Move the selection switch to the “RUN” position
c) If the programme calls for the relevant channel to
be OFF, pressing the “ADVANCE” button will
switch the relevant channel ON. Pressing the b) Press both the and the buttons to
“ADVANCE” button again, of the relevant select any of ON, 3, 2 or 1 position (i.e. “ON 3 2 1
channel will switch the relevant channel OFF OFF”).
again.
d) Press the button to ADVANCE the HOT c) Hold down both the “+” and “-” buttons at the
WATER channel same time for 5 seconds to enter the selection
mode.
e) Press the button the ADVANCE the
CENTRAL HEATING channel. d) Press either the “+” and “-” buttons to set the
room temperature set point (between 5~35°C).
10) Back Light Mode Selection
e) Press the “OK” button to activate the selected set
a) This mode enables the back light to be point.
permanently on or on for 10 seconds, after any
button has been pressed. f) N.B. In order to save battery power the room
b) Move the selection switch is in the “RUN” temperature function is only active when the unit
is connected to mains power, the function can
position. still be set-up under battery power.
c) Press the “OK” button for 5 seconds. After 5 13) Changing the battery
seconds the current setting will be displayed on
the LCD a) As the programming unit needs to be removed
from the wall, to change the battery, only a
d) Press the “+” or “-” buttons to switch between suitable qualified person should perform this
“ON” or “AUTO”. operation. See installation instructions.
e) When the desired setting is displayed press the SUNVIC CONTROLS Ltd.
“OK” button to leave this mode and return the Units 1 & 2, Block 1
programmer to normal operation. 251 Low Waters Road
Cadzow Industrial Estate
f) Note: In order to save battery power the back Hamilton
light is only active when the unit is connected to ML3 7QU
mains power.
Tel. +44 (0)1698 812944
11) Setting the Frost Protection set point Fax +44 (0)1698 813637
(if option activated during installation) Technical Helpline +44 (0)1698 810945
a) Move the selection switch to the “RUN” position N.B. In line with a policy of continuous product
development, SUNVIC CONTROLS Ltd. reserves the
right to change the specification, design and
b) Press both the and the buttons materials of products without prior notice.
to select the manual OFF position (i.e. “ON 3 2 1
OFF”).