LN40C650L1FXZA Fast Track Troubleshooting Manual Rev - 1/11/12

SERVICE BULLETINS

No Bulletins as of 1/11/12 on GSPN


POWER But see new 2010 LCD Option Byte
PCB chart.

MAIN
Insert Photo of TV Board Layout Version
Include
PCBBoard Assy names (as appearing in parts) and any
Parts No Short Description
special labels/items (i.e. Plasma voltage label) ALL BN44-00340B Power PCB
LVDS DRIVER
Function & IR PCB

CABLE BOARD ALL BN96-13226B


ALL BN94-02620N Main PCB

T-CON PCB ALL BN07-00831A Panel


SPEAKER SPEAKER
(under shield) ALL BN81-04154A T-CON PCB

HELP : 1-888-751-4086; 1-866-894-0637 (FE) FIRMWARE ALL BN96-10689A Stand Guide Neck
http://gspn3.samsungcsportal.com 10/18/2010 ALL BN96-12767B Rear Cover
Firmware for Valencia 1G Model ALL BN96-12752A Front Cover
PLUS ONE -. Version : 1030.1
http://my.plus1solutions.net/clientPortals/samsung BN96-12795C
-. Folder Name: T-VALAUSC
ALL Stand Guide

BN96-12762A
HOT TIPS -. Related Models LCD: C560 (Only ALL Stand Base

40"), C650, C670, C750 BN40-00163A


Power On Problems: (see page 2) ALL Tuner

Video Problems: (see pages 3,4) And this firmware prevents below ALL BN96-12837A Speaker

TIP: After replacing Main/Panel issues..'USB Power Overload' ALL BN96-12723C LVDS Cable

picture is upside down. message pops up even USB port is ALL 3903-000467 Power Cord
Fix: Test Mode/Mirror Option/Toggle not connected
ALL BN59-01042A Remote
No Test Patterns:Do Firmware Upgrade . Plug & Play is displayed whenever 1
BN63-01798B
turning on TV. ALL Cleaning Cloth
LN32C350D1DXZA Fast Track Troubleshooting Manual

CN201

SW-P

Wiring Diagram
Include Connector Numbers , References, and
Locations.

Power
) On Sequence (approximate Voltages)
1. Standby Voltages: CN201-4 (5V) To Force Backlight On
2. Power On CN201- 2(0 – 3V ) without Main Board :
3. Low Voltage Supplies On CN201- 1. Remove Power Cord
1,3,5,7,13,15,17 (Volts Listed on CN802) 2. Remove CN802
4. Back Light On CN201- (0-3V, delayed) 3. Plug Power Cord In.
5. Back Light Confirm CNI802- (FB1 & FB2) 4. Backlight should be
6. Dimming Signal CN201-14 (1V–4V approx) on immediately.
2
Fast Track Troubleshooting Manual
TROUBLESHOOTING VIDEO PROBLEMS
1. Verify Video Operation T-Con Troubleshooting
a. Customer Picture Test (models available)
b. “Display” (If display is OK source is suspected)
C. Substitute with known good Source
(external DVD or Signal Generator)

2. Using Test Patterns in Service Mode


- ENTER SERVICE MODE –
1. Select an active source signal. (HDMI preferred)
Test Pattern may rely on signal source to appear.
Customer Remote Service Remote
2. Power off 2. Power On
3. Mute, 182, Power 3. Info, Factory

2010 Models with FRC 120Hz/240Hz

FBE

FRC

1.Check OSD & Customer Picture Test.


2. Access SVC Mode (with source signal)
3. Activate FBE Test Patterns & Verify.
4. Activate FRC Test Patterns & Verify. 3
Fast Track Troubleshooting Manual
ON SCREEN FAILURE EXAMPLES:
ALIGNMENTS:
1. Check/Set Option Bytes:

If Picture & Display errors Green lines or a green screen


Defective Main Board, LVDS, defective main board , LVDS , or
T-CON.
or T-CON

Model Code Front


Color
Type Model Tuner Region DDR

LN40C650L1FXZA T-R- LC650 Semco US 0


Pixelization can be caused by the main board 40L1UF0C
BLK
but is more commonly a source error

2. Check/Perform Firmware Upgrade for


all repairs.
3. Perform reset in Service Mode &
Plug and Play if Main board is replaced.
SPECIAL NOTES:
Vertical or Horizontal Lines :Defective Inform customer of reset of all
Panel likely but also T-CON, LVDS, or Main Settings if Main Board or Panel is replaced.
Board. Use Test Patterns in Factory Service 4
Mode to determine error)