You are on page 1of 4
Solmetric PV Analyzer PVA Analyzer 1-V Curve Tracer oars Wireless PV Reference Sensor Nv ‘ASUS Return On Irradiance” Save time, reduce risk, and maximize ROI during: = Commissioning aM uditing 1 Troubleshooting Industry Leading Features = Highest measurement throughput even in hot environ 1 Best I-V acouracy & resolution 1 Best irradiance & temperature 1 Most reliable Go/NoGo testing wireless range user interface visualization of performance issues, ! WeaTest | Wbry | Tate Solmetric Expert Tools. Better Solar. File Properties View Usity Help 7142017 1080- Inner Contin prc 875 wim 474°C PV Array Commissioning | O&M | Auditing | Troubleshooting sng count |-V Curve Measurement ‘The I-V curve measurement provides Iso, Voc, Imp, Vip, Pmax, Fill Factor, and Performance Factor the ratio of measured to expected. = maximum power. The messure- | Setp ments ypcaly pecormed ata | ebb StS combiner box, using he fuses | 7.992000 to select the string under test. a. uieting tse 4. Cip test leads to buss bars Measurement S.lngert a fuse 6. Measure LV curve I-V Curve Accuracy and Detail The design of the PVA is ‘optimized to accurately measure | 7. Save result both standard and high efficiency | 8. Repeat for next modules, and the number of -V | _ string curve points can he switched from 100 to 500 for demanding applications. High Throughput in Hot Conditions Al -V curve tracers absorb energy with each measurement. The PVAS high thermal capacity allows it to commission 1 MW in es than 2 hours without overheating, even in environments exceeding 110°F ambient Time-Saving Interface With a tablet PC as your fy System User interface, perform more | w = Invertert tests per hour and display y ¥Combinert the data in multiple, easy y vHarmesst to read formats. Save your est measurements by touching 652 your customized array tree at > Harness? the branch you are measuring, > ¥Combiner2 ‘The software automatically > elnverter2 calculates the expected |-V curve and displays the Performance Factor. Data Analysis and Reporting ‘The I-V Data Analysis Tool, provided with the PVA, automates the process of preparing detailed professional reports of your measurement resuts ‘The tool generates a table ofthe key performance parameter values for each string, group IV graphs for ‘each combiner box, and histograms showing how the data for each parameters cstiouted ‘ a Vata) 070 SolSensor Wireless PV Reference Sensor ‘SolSensor provides radiance, temperature, ‘and module tit data to the PV model. The ‘model uses this information to predict the -V curve shape at operating conditions, and to translate the measured curve to STC. ‘SolSensor clamps to the modile frame, automatically orienting the irradiance sensor in the plane of the array. ° wee Irradiance Accuracy ‘The spectral response of SolSensor's silicon photodiode sensor is corected for the PV technology under test. Special factors are provided for multi- and mono-crystalline cals as well as Cae and other thin fim technologies. The sensor is temperature compensated and the angular response of each unit is calibrated for rotation and elevation, AAs a result of these features, SolSensor makes accurate irradiance measurements over a broad range Of technologies, sky conditions, and sun angles, allowing EV curve measurements earlier and later in the day. Temperature Accuracy SolSensor provides two extemal thermocouple inputs for measuring module backside and/or ambient ternperatures. Effective cell temperature can also be calculated directly from the measured I-V curve using methods desorbed in IEC 609046 ‘The PVA's SmartTemp feature blends these two methods for best advantage. Temperature is calculated from the measured |-V curve at high irradiance, taken from the thermocouple at low irradiance, and derived from a blend Of the two at intermediate irradiance values. Wireless Interfaces ‘The PVA communicates with your PC by Zigbee (PVA-1000) or WiFi (PVA-1500). The SolSensor has a line of sight range of 100 meters. That means no wires underfoot, quick setup, and the ability to move around while troubleshooting strings, Measue multiple combiner boxes with a single SolSensor setup, PV Analyzer Includes: ‘* FV Measurement Unit with shoulder strap PVA Software for Windows™ + Alligator clip test leads MC-4 to MC-4 ‘connector savers’ MC-4 connector tool Battery charger (AC adapter) Data Analysis Too! SolSensor Includes: © Sensor unit ‘+ Module Frame Clamp ‘+ Ruggedized K-type thermocouples (2) + Thermocouple attachment adhesive discs (60) ‘* SolSensor tool lanyard * Irradiance sensor cleaning supplies ‘© Shoulder bag Solmetric Headquarters 117 Moris St. ‘Sebastopol, CA 95472 ‘www solmetric.com email: info@solmetric.com Tet: +1-707-828-4600 Printed on recycied paper. General Information eco PES High-efficiency PV Engineered to accurately measure high-ficiency as well as modules tandard PV modules and strings, User interface Bright, colorful graphics and touch screen controls for ‘operator efficiency, ease-of-use, and in-field analysis. Runs (on user's standard Windows laptop or tablet, Wireless interfaces Wireless interface between your PC and th Measurement unit and between LV unit and SoiSensox. ‘Advanced PV models Accurately predicts performance at both STC and current ‘conditions. Checks your results immediately. Equipment databases Models for 50,000+ PY modules. Automatic updates High Throughput ‘Measure 1MiV in less than 2hrs at 110°F ambient, ‘Thermal Capacity 800 measurements at 25°C ambient, 260 measurements at 45°C ambient, in example PV systems with 1900V Voo, 16 strings per combiner, and 5 min. to move to next combiner. I-V Specifications od PV voltage range ‘o-1000¥ 0-1500V Current range 020,030 OSA Voltage accuracy (1045 area 20.5% £0.25 Current accuracy (010°C arbon) 40.5% + 0.048 Resolution 25 mv, 2 mA, Current resolution ams Measurement cycle time ‘ypioa, measurement-to-measuremant LV sweep duration 0.05 - 2s. Typically 0.2s for PV strings. /-V trace points 100 oF 500, user selectable Operating temperature ron) 1010 +45°C Battery lite ‘Bhs continuous operation, 1000 LV curves Protection features (Over veltage, current, -temperatixe, ‘and reverse potarty Safety ‘CAT II, 1000 ce cari SolSensor Specifications radiance aciracy 32% pc (100 500 Wi, son cls) Sime ease ern Tilt accuracy 22° typical (0-45°) Measurement inter adercs: 0.1 Tonos Sisters 10m oven ino sh Operating temp 1010 +45°C

You might also like