You are on page 1of 4
RAXIS AUTOMATION TECHNOLOGY Mega-Guard PMS: a nec Coa oc) ‘Synchronizing and load sharing Consumer blocks and preferent tripping Measuring and display (KW, V, A, Hz, Cos @) UR con Dee eas Supports split busbars and bus tie breakers No seperate gauges required (option) Cre elmo) Die eae Ls CE) bd PRAXIS AUTOMATION TECHNOLOGY 4a Vv 418 A 233 kW weno > System lay-out “The Mega-Guard PMS is consists of three items for each generator set: ‘©. PMS Operator Pane! ‘Size: 144x144x55mm (WxHxD) for flush panel mounting © PMS /0 Module Size: 127x198x2amm (WxHxD) for Din rail mounting, ‘© 1/0 Cable in between PMS Operator Panel and PMS (0 Module with a length of 3 or 5 meter ‘The PMS Operator Panel's flush mounted in the front door of the switchboard and contains a user-friendly graphie display for read-out of power plant parameters and 12 pushbuttons with, amp indicators for operation of the generator set Tho PMS I/O Module is DIN rail mounted inside the switchboard and contains inputs and outputs to connect to diesel engine, (generator, busbar and main circuit breaker. The HO Cable inter-connects the PMS Operator Panel and the PMS /0 Module. ‘The PMS can be extended with 24 channel Mixed JO Module Which suppor the following functions: «Safety system for diesel engine with 4 monitored digital inputs and ‘shutdown relay output. ‘© Analog control for voltage and frequency: 4 analog outputs 4-20mA. 24 > Features ‘The Mega-Guard Power Management System (PMS) is an. advanced system for full automation of power plant including power management, diesel engine control, {generator control, synchronizing, generator protection and. ‘Optional diesel engine safety system. Each generator set Is ‘equipped with its own independent and autonomous PMS. system. This ensures the highest degree of reliablty and availabilty. The Mega-Guard PMS is supplied as a complete product and no additional components are needed for, Automation of a low voltage switchboard up to B90VAC. ‘The graphic display clearly indicates breaker status (open! Closed), generator power, generator voltage, generator ‘current, power factor, busbar voltage and. frequency. ‘The standard Mege-Guard PMS js very easy to configure during installation. A user friendly menu driven user interface ts available on the graphic display of the PMS. Parameters such as generator power, number of ‘generators, position of bus tie breaker, busbar nominal Voltage, alarm limits, diesel/shaflishore generator etc, can easily be filed in ‘The Mega-Guard PMS can be extended with '# Safely system for diesel engine, ‘© Check synchronizer with back-up measurement of kW, V, A, Hz/and Cos 9. ‘© Analog control for frequency and voltage i A : a a Hl i D4 PRAXIS AUTOMATION TECHNOLOGY > PMS Operator Panel ‘The PMS Operator Panelis installed inthe front door of the switchboard at each generator section, The Operator Panel provides an user-friendly interface for operation and monitoring of the generator set, The PMS Operator Panel is equipped with built-in Control Processor function and executing power management functions. The PMS Operator Panel is delivered with ‘graphic LCD display which provides the following information: © Generator power ‘© Busbar voltage © cose © system status © Generator voltage © Frequency © Breaker status © Alarm description In addition the PMS Operator Panel is equipped with the following Operator pushbuttons with lamps © Auto / manual © Bun © Trefease decrease» Menu © Start/ stop © Open /ciose ‘© tst/ 2nd standby. * Alarm ‘The rear side of the PMS Operator Panel is equipped with terminal strips and connectors as follows ‘* Redundant Ethemet link for corrimunication S¥stem fail output to other PMS Operator Panels and (when installed) _@ "USB port formemonyistick to up-idownload an application program. to Mega-Guard Operator Workstations. '* RS485 MODBUS slave communication port ‘© Power supply input 19~32VDC. ‘© /O bus connector for connection of /O Cable. > PMS I/O Module ‘The PMS JO Module is installed inside the main gwitchboardat each {generator section, lO signals from generator, busbar, circuit breaker and engine are directly connected to this iO Module. ‘The PMS iO Module Is equipped with a controller which executes {generator control functions and the I/O Module communicates with the PMS Operator Panel, The VO Module can also be delivered as an Independent Check synchronizer. e OOOO OAaae ‘The PMS 1/0 Module has the following inputs and outputs: +3 phase busbar voltage (0-890VAG), # 3 phase generator voltage (0-690VAG) + 3 phase generator current (0~BA) *# Relay outputs (6) =€B close /open Engine increase / decrease speed = Engine start/stop © Digital inputs (6) 0 000000000000000000000000000 Cree UOC Ie Ieee eee reer "ast ney srt fesse ian “Seb Ps seb E “Eng Sa or pee | fe | +t ots (6) eacortovatls nce en ae Q | | 2 a a) a) a) a) | ty) | | ty = Consumer block accept (1~8) _- AVR increase voltage = Preferential trip (1~8) - AVR decrease voltage QD ee peer Ca — =CB abnormal tip = Voltage alarm high low O —_ oo casement Beidina Olen arr Ct] e Es Eee 2 von eh Sy n=] ST Ei Sie ee eee rae Erne) Pus Pus | pert Operator | Panel Panel IM) Fuses 0 Cable 0 Cathe | i rses io Cable Pas Pas Pus wo Module to Mode vo medic aeciers))\\)\) eee pester? ashe i Engine Mega-Guard Ship Automation and Navigation System ‘Alarm Moning Valve Contvol and Power Propulsion Coy ra ‘and Control System Monitoring System Management System Control System Sea oc co) eat ema) a) Coe Heading Ga us Core) Peer) Bdge System Catcut CoS cL oe ace ec) Branch offices: Head office: Your representative: Praxis Automation Technology B.V. Zildijk 248, 2352 AB Leiderdorp, The Netheriands. Praxis Automation China '@ +31 (0)71 5255 353 4 +31 (0)71 5224 947 Praxis Automation Korea SS IRCceET women, ¢PRANIS AUTOMATION TECHNOLOGY

You might also like