Professional Documents
Culture Documents
Alcatel-Lucent 7450 ESS: Ethernet Service Switch - Release 7.0
Alcatel-Lucent 7450 ESS: Ethernet Service Switch - Release 7.0
E t h e r n et S e r v i ce S w i tc h | Release 7 . 0
The Alcatel-Lucent 7450 Ethernet Service Switch (ESS) is a high performance MPLS-enabled Carrier Ethernet
platform providing high-speed Ethernet service delivery and high-density service aggregation at the Carrier
Ethernet service edge. With industry-leading throughput, density, reliability and service depth, the 7450 ESS
is the platform of choice to enable wide scale Carrier Ethernet adoption, implementation, and transformation.
7450 ESS-12 7450 ESS-7 7450 ESS-6 7450 ESS-6v 7450 ESS-1
System throughput • Switch fabric: Up to • Switch fabric: Up to • Switch fabric: Up to • Switch fabric: Up to • Switch fabric: Up to
1 Tb/s (half duplex) 500 Gb/s (half duplex) 320 Gb/s half duplex 320 Gb/s half duplex 40 Gb/s (half duplex)
• Slot capacity: Up to • Slot capacity: Up to (non-redundant with (non-redundant with • MDA half-slot capacity:
50 Gb/s (full duplex) 50 Gb/s (full duplex) graceful degradation); graceful degradation); Up to 10 Gb/s (full
up to 160 Gb/s half up to 160 Gb/s half duplex)
duplex (fully redundant) duplex (fully redundant)
• Slot capacity: Up to • Slot capacity: Up to
40 Gb/s full duplex 40 Gb/s full duplex
(non-redundant); up (non-redundant with
to 20 Gb/s full duplex graceful degradation);
(redundant) up to 20 Gb/s full
duplex (redundant)
IOM support • IOM-20G • IOM-20G • IOM-20G • IOM-20G • One integrated IOM
• IOM3-XP • IOM3-XP • IOM3-XP • IOM3-XP and SF/CPM
• Up to 10 per chassis • Up to 5 per chassis • Up to 4 per chassis • Up to 4 per chassis
Number of half-slot • Up to 20 – Any mix of • Up to 10 – Any mix of • Up to 8 – Any mix of • Up to 8 – Any mix of • Up to 2 – Any mix of
MDAs per chassis MDA or MDA-XP MDA or MDA-XP MDA or MDA-XP MDA or MDA-XP MDA or MDA-XP
Common Equipment • SF/CPM, power entry • SF/CPM, PEM-3, fan • SF/CPM, PEM-3, fan • SF/CPM, PEM-3, fan • Power, fan
Redundancy module-3 (PEM-3), fan
Hot-swappable • SF/CPM, PEM-3, fans, • SF/CPM, PEM-3, fan, • SF/CPM, PEM-3, fan, • SF/CPM, PEM-3, fan, • Integrated IOM and
modules IOM, MDA, ISA IOM, MDA, ISA IOM, MDA, ISA IOM, MDA, ISA SF/CPM, MDA and
power
Dimensions • Height: 62.2 cm (24.5 in.) • Height: 35.56 cm (14 in.) • Height: 35.56 cm (14 in.) • Height: 80 cm (31.5 in.) • Height: 6.7 cm (2.6 in.)
• Width: 44.5 cm (17.5 in.) • Width: 44.5 cm (17.5 in.) • Width: 44.5 cm (17.5 in.) • Width: 46.5 cm (18.3 in.) • Width: 44.5 cm (17.5 in.)
• Depth: • Depth: 64.8 cm (25.5 in.) • Depth: 64.8 cm (25.6 in.) • Depth: 45.5 cm (17.9 in.) • Depth: 56.4 cm (22.2 in.)
¬ Without cable guides:
65.4 cm (25.75 in.)
¬ With cable guides:
76.5 cm (30.1 in.)
Weight • Empty: 33.1 kg (73 lb) • Empty: 27.2 kg (60 lb) • Empty: 32.7 kg (72 lb) • Empty: 54.4 kg (119.7 lb) • 27.22 kg (60 lb) chassis
chassis weight with two chassis weight with 2 chassis weight with, chassis weight with weight
fan trays and air filters fan trays and air filters PEMS, two fan trays PEMs, fan trays and
• Loaded: 152 kg (335 lb) • Loaded: 70.5 kg (155 lb) and air filters air filters
approx. approx. • Loaded: 89 kg (195.8 lb)
approx.
Power • -40 V DC to -72 V DC • -40 V DC to -72 V DC • -40 V DC to -72 V DC • -40 V DC to -72 V DC • 110 V AC or 220 V AC
• 90 A to 162 A • 52 A to 93 A • 41 A to 75 A • 41 A to 75 A • -40 V DC to -72 V DC
• 1+1 redundancy • 1+1 redundancy • 1+1 redundancy • 1+1 redundancy • 10 A to 6 A
• 1+1 redundancy
• AC available with
external shelf
Cooling • Front-to-back air flow • Side-to-back air flow • Side-to-back air flow • Front-bottom intake, • Side-to-side air flow
rear top exhaust
MDA TYPE PORT COUNT INTERFACE TYPE ESS-1 ESS-6 /ESS-6V ESS-7 ESS-12
ETHERNET MDA-XPs
3HE04834AA CH-BN 7450 ESS-12 DC + SF/CPM-3 BNDL 7450 ESS-12 DC + ESS-12 SF/CPM-3 Bundle. Includes: 7450 ESS-12 DC integrated chassis (1 x
3HE02033BA) which includes redundant DC PEM-3s (2 x 3HE03666AA), impedance panels (2
x 3HE04150AA, 5 per pack) and non-redundant 7450 ESS-12 SF/CPM-3 (1 x 3HE03618AA).
3HE04835AA CH-BN 7450 ESS-7 DC + SF/CPM-3 BNDL 7450 ESS-7 DC + SF/CPM-3 Bundle. Includes: ESS-7 DC integrated chassis (1 x 3HE00387CB)
which includes redundant DC PEM-3s (Slot-1 3HE03665AA & Slot 2 3HE03664AA), impedance
panels (1 x 3HE04150AA, 5 per pack), a high flow fan tray, fan filter and non-redundant 7450
ESS-7 SF/CPM-3 (1 x 3HE04166AA).
3HE00314BC CH-BN -7450 ESS-7 AC BNDL 7450 ESS-7 AC Chassis Bundle. Includes: 7450 ESS-7 AC integrated chassis (1 x 3HE00387BA)
which includes non-redundant SF/CPM-2 (1 x 3HE01172AA) and an ESS-7 AC power supply (1
x 3HE00187AA).
3HE02329BA 7450 ESS-6 DC Chassis Bundle 7450 ESS-6 DC 6 Chassis Bundle. Includes: 7450 ESS-6 DC integrated chassis (1 x 3HE-
02305BA) which includes redundant DC PEM-3s (Slot-1 3HE04151AA & Slot-2 3HE04152AA),
two (2) fan trays, a fan filter and a 80G SF/CPM (1 x 3HE02297AA, one (1) required per 7450
ESS-6 slot Shelf, up to two (2) per 7450 ESS-6 slot Shelf for CPU and fabric redundancy).
3HE04182AA 7450 ESS-6V DC Chassis Bundle 7450 ESS-6v Vertically Oriented 6-slot Chassis Bundle. Includes: 7450 ESS-6v DC integrated
chassis (1 x 3HE03668AA) which includes redundant DC PEM-3s (2 x 3HE04170AA),
impedance panels (4 x Impedance Panels), two (2) fan trays, a fan filter and a non-redundant
80G SF/CPM-2 (1 x 3HE02297AA).
3HE00226AC SYS - 7450 ESS-1 AC/DC 20G SYSTEM 7450 ESS-1 20G System. Includes One (1) AC and one (1) DC PEM and an integrated Switch
Fabric and CPU/IOM with 20 Gb/s forwarding capacity. Accepts up to 2 MDAs.
3HE00226AB SYS - 7450 ESS-1 DUAL DC 20G SYSTEM 7450 ESS-1 20G System. Includes redundant DC PEMs and an integrated Switch Fabric and
CPU/IOM with 20 Gb/s forwarding capacity. Accepts up to 2 MDAs.
• ITU-T G.8263 - g.paclock.bis – Synchronous • IEC CISPR22 • ETS 300 019-1-1, Storage Tests, Class 1.2
status messaging (SSM) echo support • AS/NZS CISPR 22 • ETS 300 019-1-2, Transportation Tests, Class 2.3
• ITU-T G.8264 - g.pacmod – Distribution of Immunity • ETS 300 019-1-3, Operational Tests, Class 3.2
timing through packet networks • EN 61000-3-2 Power Line Harmonics • ETS 300 019-2-4, per A1 Seismic
• EN 61000-3-3 Voltage Fluctuations and Flicker Environmental specifications
Safety standards and compliance
agency certifications • EN 61000-4-2 Electric Static Discharge • Operating temperature: 0°C to 40°C
• EN 61000-4-3 Radiated Immunity (32°F to 104°F)
Safety
• EN 61000-4-4 EFT • Relative humidity: 15% to 85% (non-condensing)
• EN 60590-1
• EN 61000-4-5 Surge • Operating altitude: sea level to 3048 m
• IEC 60950-1CB Scheme 10,000 ft)
• CSA/UL 60950-1 NRTL • EN 61000-4-6 Low Frequency Common
Electronic equipment devices
• FDA CDRH 21-CFR 1040 • EN 61000-4-11 Voltage Dips and Sags
• WEEE
• EN 60825-1 Telecom
• RoHS
• EN 60825-1\2 • Telcordia GR-253-CORE Issue 3
• R&TTE
• IEC 60825-1 • IEEE 802.3 (Gigabit Ethernet, Ethernet)
• China CRoHS
• IEC 60825-2 • ANSI T1.105.03
Certifications
EMC • ANSI T1.105.06
• Network Equipment Building System (NEBS)
• ICES-003 Class A • ANSI T1.105.09 Level 3
• FCC Part 15 Class A • ANSI T1.403 (DS1) ¬ Telcordia GR-63-CORE, Issue 4, June 2006
• EN 300 386 • ANSI T1.404 (DS3) ¬ Telcordia GR-1089-CORE, Issue 3, March
• EN 55022 • ITU-T G.957 2006
• EN 55024 • ITU-T G.825 ¬ ATT-TP-76200
• EN 61000-4-2 • ITU-T G.824 • CE