CASTCO EARKRR PARADA CASTCO TESTING CENTRE LTD. Test Certified Drift Expanding Test of Copper and Copper Alloys (Seamless) Round Copper Tubes for Water, Gas in Sanitary, and Heating Applications (BSEN 1057 : 2006+A1 : 2010 Clause 7.7) (Test method : Clause 10.7) Date of issue : 16 May 2013, Page 1A_of_1_page Castco LRN: DPO121109-044 DE Details as supplied by customer Customer: Shun Lee Bldg. Materials & Sanitary Wares Ltd Customers ref. no: == Contract no.: Job titles = Deseription of tube: Nominal outside diameter: 22 mm Copper Pipe ‘Nominal thickness: 0.9 mm Brand name: DECO Material temper: R250 Body marking: DECO COPPER TUBE BS EN10S7 TYPE X I-LU/jf 22 x 0.9 20081V Delivery date: — Laboratory Test Result Date sample received: 09 November 2012 Date oftest : 11 December 2012 Ambient temperature: 21 °C Specimen no P0121 109.044 Length co) 33 Original ouside diameter (D1) ca) 2 Final tube outside diameter (D2)=D1 x 13, «nm 29 est result Passed Remarks; 1. The drift expanding test was caried out by using 48° mandrel 2. Test results relate only to the specimen teste 3. Test result af the sample comply with the requirement of BSEN 1057 : 2006 Clause 7.7+A1 : 2010 & Clause 10.7. 4, This test report supersedes previous test report of Castco LRN : DPO12! 109-044 DE, issued on 21 January 2013. FU HO MAN End of Re GHEUNG CHIN KEUNG astan Ted Onr PR OF Report 8s MS, DIG MBE, MIKE feo, PEDETO) Tao 12 Pz (Gi 0) Daeeor 498} HEH GIB 99, On Kui Steot, Fanling, Hong Kong. Tel: 2677 2198 HBB ABIIVAB 294, On Chuon Svedt, Faning, Hong Kong. Fax: 267 0964 E-mail castoo@ nelvigatorcam Website: wnw.casieo.comnk ABR P SARA A CASTCO TESTING CENTRE LTD. Test Certified Hydrostatic Test on Copper and Copper Alloys (Seamless) Round Copper Tubes for Water, Gas in Sanitary, and Heating Applications (BSEN 1057 : 200641 : 2010 Clause 7.4) (Test method : Clause 10.9 Method C2) Date of issue : 16 May 2013, Page IA_of_1_page Casteo LRN:_DPO121109-044 HYD ‘Details as supplied by customer Customer: Shun Lee Bldg, Materials & Sanitary Wares Ltd, Customer's re. no.: = Contract no.: Job title: — Description of tube Nominal outside diameter: 22 mm Copper Pipe Nominal thickness: 0.9 mm Brand name: DECO Material temper: R250 Body marking: DECO COPPER TUBE BS EN1057 TYPE X I-L-ifft 22 x 0.9 20081V Delivery date: ratory Test Result Date received: 09 November 2012 Date of test: 12 December 2012 Specimen no, DPO121109-044 Hydrostatic pressure apply (bar) 35 Sustain period (see) 10 JObservation No leakage was observed [Test result Passed Remarks: 1. Test results relate only to the specimen tested, 2, Test results of the sample comply with the requirement of BSEN 1057 : 2006+A1 : 2010 Clause 7.4 & Clause 10.9 Method C2. This test report supersedes previouis test report of Castco LRN : DPO121109-044 HYD issued on 21 January 2013, FU HO MAN End of Report cn 1 Testes Or ia CHEUN pom rerio vant : Sagem Mae, a, H9E (Chi & Gs) Diver £3 D MEE W339, On Kul Fanling, Hong Keng. Tel 2677 2198 $BMRAA2A — 20, On Chuen Street, Fang, Hong Kong. Fax: 2677 0981 E-mal: castoo@netvigator.com Website: wwwcasico.com.hk £ARRKRPORRAA TTS ie) CASTCO TESTING CENTRE LTD. ‘Test Certified Dimensions and Tolerances on Copper and Copper Alloys (Seamless) Round Copper Tubes for Water, Gas in Sanitary, and Heating Applications (BSEN 1057: 2006+A1 : 2010 Clause 7.3) Date of issue : 16 May 2013 Page IA of I page Castco LRN: DP0121109-044 DIM Details as supplied by customer Customer: Shun Lee Bldg, Materials & Sanitary Wares Ltd. Customers ref. no.: Contract no.: — Job ttle: Description of tube: Nominal outside diameter: 22 mm Copper Pipe Nominal thickness: 0.9 mm Brand name: DECO Material temper: R250 Body marking: DECO COPPER TUBE BS ENI0S7 TYPE X --U/ff-22 x 0.9 20081V Delivery date: Laboratory Test Result Date sample received: 09 November 2012 Date of test: 11 December 2012 Specimen no.: DPO121109-044 Measured value (mm) Result Mean Outside diameter 2.03 Passed Thickness 0.92 Passed Length 2507 Passed Remarks: 1, Test results relate only to the specimen tested, 2. Test results ofthe sample comply with the requirement of BSEN 1057 : 2006+A1 : 2010 Clause 7.3. 3. This test report supersedes previous test report of Castco LRN : DPO121109-D44 DIM issued on 21 January 2013, Ceci t contiethy bi 50 MAN GHEUNG CHIN KEUNG jp Fs MS, DC, MSE End of Report 8 MS DI SE ren, PED 8, Fao Diese HB HRB HTI3M 93, On Kui Street, Fanling, Hong Kong, Tel: 2677 2198 BRA A2AB 200, On Chuen Street, Fanling, Hong Kang, Fax: 2677 0351 E-mail: castco@netvigator.com Website: vivw.casteo.com hc 4 HRB SARA A CASTCO CASTCO TESTING CENTRE LTD. Test Certified Surface Quality by Carbon Film Test (BSEN 1057 : 2006+A1 : 2010 Clause 7.5) [Test method : Clause 10.5 (Annex B)] Date of issue : 16 May 2013 Page 1A of 1 page Castco LRN: DPO121 109-044 CF Details as supplied by customer Customer: Shun Lee Bldg. Materials & Sanitary Wares Lid. Customer's ref. no.: -- Contract no.: — Job title: — Description of tube: Nominal outside diameter: 22 mm Copper Pipe Nominal thickness: 0.9 mm Brand name: DECO Material temper: R250 Bory marking: DECO COPPER TUBE BS ENI0S7 TYPE X I-LU/ff 22 x 0.9 20081V Laboratory Test Result Date sample received: 09 November 2012 Date oftest : 14 December 2012 Specimen no. Specimen size Test result DP0121109-044 Length : 25 mm Passed Remarks : 1, Test results relate only to the specimen tested. 2. "Passed" refers to "No detection of carbon” and “failed” refers to “detection of earbor 3. Test results of the sample comply with the requirement of BSEN 1057 : 2006 Clause 7.5A1 : 2010 & Clause 10.5 (Annex B), 4, This test report supersedes previous test report of Castco LRN : DPOI21 109-044 CF issued on 21 January 2013 FU HO MAN ssisun Teta De Bnd of Report Fo Na PE SOY 06- 601012 Be, MSe, DIC, MStEog), MIIKTE, TE (Cn & Ge) Diese # 16-0 BE A KG33H 93, On Kul Stroot, Fanling, Hong Kong. Tel: 2677 2138 &®OPHEZ VAG 200, On Chuen Stost, Fanting, Hong Kong. Fax: 2677 0361 E-mal casteo@netvigator.com Website: waww.casico.com.hk EARRR PCHRD A be Cc La Ss a iS O CASTCO TESTING CENTRE LTD. ne ‘& iH BS EH 334E — 33, On Kui Street, Fanling, Hong Kong. Tel : 2677 2138 BN) EE HA29A 29h, On Chuen Steet, Fanling, Hong Kong. Fax: 2677 0351 << dat ek pc ect eer snggsue Vickers Hardness Test on Metallic Materials (BS EN ISO 6507: 998) Date of issue : 16 May 2013 Page 1A of 2 pages Castco LRN: DP0121109-044 VH Details as supplied by elien Client: Shun Lee Bldg. Materials & Sanitary Wares Ltd Client's ref. no. : Address : 15/F, Grandion Plaza, 932 Cheung Sha Wan Road, Lai Chi Kok, Kowloon Contract no, : Job title : Test location / site: Castco Testing Centre Ltd. Acceptance standard : BS EN1057 : 2006 + Al: 2010 ‘Test piece no.: DP0121109-044 Test results: Date received : 09 November 2012 Date of test : 20 December 2012 Parent metal : Copper Pipe DN22, Temper R250 ‘Thickness of material : 0.9 mm [Sketch of Test locations ‘Testing Technique = Requirement 1. Rangeof Hardness HVI-HV30 2. Timetoatains the specified force 2s fs 3. Hold time 105~ 15s 4. Ambien temp. asc 5. Test piece thickness >is 6, Test piece surfaces, Top and boom Clean, smooth 7. Rigid support surce (Clean, smooth 8. During testing displacement at id suppor, no shock r vibration 9. Bdge clearance 225d 10, Centre to cei clearanoe aod 11, Comeston factors o curved sunfices Table BIB "HKAS hs ssc ns aboriy (Re. No 082- TEST ander HOKLAS fraps abraer vives india te HOKLAS dor oFonedeobooriesThisreport salar be ‘poco ls ith pr wn pprval fr his abr Ths abr iad n accordance wi the econ nctionl Saar SOFC 170252008. Ths ‘Gratinen dampen tetinleompeterc ora define scaeande operon fasbosar qa wanagenentye efron ISO AC1AFCommanigse ded amar 2009) LARA POARAA CASTCO CASTCO TESTING CENTRE LTD. HE # iB BA AP33R 33, On Kui Street, Fanling, Hong Kong. Tel : 2677 2138 #188} HEE AIIA 294, On Chuen Steet, Faning, Hong Kong. Fax: 2677 0951 02s ose Exmall: cateoGnetvgator.com Wobste: wwni.casteo. com Mest Report ad Vickers Hardness Test on Metallic Materials (BS EN ISO 6507 : Part 1 : 1998) Date of issue : 16 May 2013 Page 2A of 2 pages Castco LRN : DPO121109-044 VH. Test results: Test | “dt ] “42 | Mean [*bimenc] “Hardness |] Test | *at | “a2 | Mean [*vitieened “*Hardness locations | (mm) |_(mm) | (mm) |__| reading (HV) | tocations |_ (mm) | (mm) | (mm) | (%) | reading (HV) 1] 0340 [ 0339 | 0340 | 03 80.2 “4= diagonal of the indentation * Readings high lighted, [f dl & d2 difference for more than 5% * Round off to nearest 10 HV Remark: 1, Test results relate only’to the specimen tested. 2, Compliance of the test results tothe specification is an opinion of te laboratory and is not covered under the HOKLAS accreditation 3, Body marking: DECO COPPER TUBE BS EN10S7 TYPE X HL-V/fif 22x 0.9 20081V 4, This test report supersedes previous est report of Castco LRN : DPO121109-044 VH issued on 21 January 2013. t FU HO MAN Checked by: ee Approved Signatory CHEUN ‘cas haste wien Ren No O2-TEST ad HORLAS locate HORLAS enh cred masts epral ote {pou ul ah ps aon spol fy bivny To nb CORED eran wit te opie iene Sa gBOTEC 70200 Ths ‘Murnkntonawpatettntnialsoeeydarsors tied ccopeand te operation bora gai mangennteyserreferjamlSO.1 CLAP banque da ana 203)

You might also like