The All SE/OF’s, Under DHBVN Memo No.Ch; 8 /DDD-193/P&D Dated — 14/05/2018 Subject:- Labour Schedule Rates/Erection Charges (after inclusion of GST impact) Estimation purpose) for 33 KV, 11 KV & LT turnkey works w.e.f 14.05.2018. Enclosed please find here with the Labour Schedule Rates/Erection Charges (including GST) for Estimation purpose of 33 KV, 11 KV & LT turnkey works duly approved by WTDs of DHBVN on NP-8 of file DDD-193/P&D as per recommendation of committee of DHBVN The above rates are applicable w.e-f. 14.05.2018. This is for your information & taking further necessary action in the matter, please. DAV As Above fess vas re Superintending Engineer/P&D, For CEIPD&C, DHBVN Hisar co. 1. SPS to worthy Chairman-cum-MD, DHBVN/UHBVN for kind information of worthy Chairman please, PS to Director/Projects, DHBVN, Hisar for kind information of the Director/Projects please. PS to Director/Operation, DHBVN, Hisar for kind information of the Director/ Operation please. 4. All Chief Engineer's & CAO under DHBVN Hisar for kind information and further necessary action please. 5. SE/T, DHBVN Hisar for information and with a request to ensure the uploacing the same on Nigam website for circulation. ‘8£/Construction Circle, DHBVN Hisar for kind information and further necessary action please. ‘SE/MBP Circle, DHBVN Gurugram for kind information and further necessary action please COS, DHBVN Hisar for kind information and further necessary action please. All Xen/Ops, under DHBVN Hisar for kind information and further necessary action please. 40. All Xen/works under DHBVN Hisar for kind information and further necessary action please. 44. All XEN/Const /DHBVN, Hisar for kind information & further necessary action, plese. 12, CGMIPD&C, UHBVN, Panchkula for kind information and further necessary action, please. en 2 on (c\User\dhbon\oosktan\Letters (1).docx a Labour schedule, rates /Erection Charges for Estimation purpose w.e.f 14.05.2018, ; | —Tabour 1] | Sr. No, Description Unit Erection rates | L eae oe in Rs. | | SUB HEAD- (A) Erection of supporis for lines varying from 41 KV to 33 KV complete with accessories including Insulators, +_ | Erection of Sey set compete. Ore no. 299.00 [9 | restonFiing Staystut sty setcompito min 822 PY | Ong o, —at900 | long pole | Erection of Fiying Stay Set with 4-6 Mtr. (12420) long pole on | 3 | the road side/strect Coisbiatel sttinaceat 4 | Erection of H.T. Dead End, H. Pole structure with two stays, Oneno, | 1646.00 5 | Erection of 11 KV Tesoff equipment complete with one stay set. | Each | 748.00 [6 _| Erection of HT. Concrete roles. (14 mtr ong) Each 888.00 [7 _| Earthing of H.. poles with road Ore no. 151.00 3 | Earth boring Feet 31.00 ‘Add 20% extra for erection of H.T. & L.T. poles in Hilly Zones & in the area's where metalled / | ‘Cement Concrete road is to be broken ‘SUB HEAD- (B) Erection of supports for L.T. lines complete with accessories. 7 | Erection of L.T. Tee-off equipment. Each 291.00 2 [Erecton of LT. 3 pase ogu pment Each) as2.00 3 Earthing of L.T. poles with rod. : HH ‘One no. 151.00 47 [emetion of PCC 9 Mes, 27) LT. pole Tach | 708.00 5 Erecton of LT. Capacitor, ech] 4.00 @ | Fixings of Egg. Type insulators in old stay sets. Each 54.00 “SUB HEAD. (G) Erection of Sub-station complete with accessori L a 1 Erection of 100 10200 KVA “Fs with pole mounting subvstation. | Each 3075.00. | 7 7 1 2 _| Erection of 25 & 63KVA T/Fs with pole mounted Sub-Station. Each 2683.00, 3_| Erection of 17 KV Lightening Avrestors Set ‘One Set 559.00 4 _| Erection of R.D. Fuses with Fittings Each 3_| Erection of Cables box with fitings. a | Each Erection of ransformer on plinth above 200 KVA to 600 KVA ae 1114 complete in all respect. Erection of transformer on plinty above 500 KVA to 1000 KVA con 111.4 complete in al respect. .[_ 8 | Erection of 11 KV VCB Breer eeere Each / Erection of Automatic Reclosures complete with filings, Jumpers, | @ | insulators platform and tear thing etc. Each rE ‘Cllnlanbr\deatp\commtse erator erection rates new 14518 (2) (1).docx Page 1 Woe Erection of Sub-Station structure steel work, frame and bus bars ete For one Panel Each For two panels Eacn For three panels wy) _| For four panels 11_| Welding of Transformers with Platform at sie Each 90.00 72_| Replacement of Thimble for HT Gable _ Each 55.90 < ‘SUB HEAD. (0) | Erection of conductor wires etc. complete with accessories. +1 _ | Stinging & Sagging of Conductor of sizes single wire including jointing Ff and binding with insulatore at supports. )_[AOSR Conductor 30mm2 per km 1230.00 [iy TACSR Conductor Somm2_ per km 2070.00 fi)_| ACSR Conductor 60mm2 “| perkm | 2520.00 iw)_[AGSR Conductor 100mma perk 3350.00 v)_ | ACSR Conductor 130mm (leopard) 7 per km 4470.00 vi)_| ACSR Conductor 150mma perk | 6590.00 vi)_ | ACSR Conductor 0.2 89, Inch (panther) perkm 8390.00 wil) | OSL No. & SWG. f 7 perkm 1120.00 | ig)_| Earth Wire 7/14 SWC. Het per km 1620.00 ‘Making and fixing of cradle guards H.T. & LT. Each | 28.00 ‘Making and fixing of cage guards. Each 67.00 [Erection of LT. Lighting Arrestors (set of 3) | eech_| 447.00 SUB HEAD- (E) Erection of L.T. Cables In position including accessories, bearer wire joints otc. LT. PVE SiG CABLES Y_| S650 mma 100 Mir 430.00 i) [SiC 95 mma 100 Mi 615.00 wwy_[ SIG 120 mma. 100 Mtr. 738.00 iv) [SiG 165 mma i 100 Mtr 983.00 | Sic 300 mma 700 nit. | 1963.00 [wn [sie 60mma oe Yoo Mu. | 2094.00 2 | Erection of2iGore PV Sub Man of sizes, | 46,t0mm2 a 100 Nit. 03.00 (Ti [PiGore PVC 16mma coer oo Mr | _ 671.00 | Making Straight through or T. Joint of PVG Rubber | each 73.00 | 4_| Fixing of Load T-Box or link box. Each 39.00 [5 [Erection of Sealing end __ [Bach 73.00 Erection of 4/Core PVG cable of sizes complete in position. y foe a ‘come [6800 jem tome. | 1418.00. | ee TiomAsihnekcp\Cemeee perf erection rates new 14518 (2) (1).docx Page? ee Erection of 3.5/Core PVC cible of sizes complete in position. 3.50 x 95mm2 “00 Mate 167.00 3.50 x 120m Yoo mir. | 2012.00 3.50 x 185mm2 100 Mir. 2683.00 | 3.5C x 300mm2 : 100 Mtr. | 3364.00 Erection of LT. Armoured Gable of sizos complete in position. ) | 2cemme E - 400 hte 615.00 it) | 2/10mma Ere 7 100 tir. 615.00 [ip [3.576 25 mm2 as 400 Mtr. 4230.00 Ww) | 3.5/C 50 mm2 400 Mtr. 7230.00 | Wwe [S5co5mme 400 Mir 1761.00 wb. | 3.5/6 120 mme __ 100 Mir 2113.00 v)_ | 4Cxtemm2 z yoomi. | 1008.00 vv) | ACx2Emm2 Greece voor. | 1250.00 ‘9 | Erection of Channel Iron / Angle Iron with catenary Stay. | One No. 151.00 [SUB READ-(F) : Erection/laying of H.T. & L.T. cable underground, including digging and refiling oftrenches etc. 1 | ET. ARMOURED CABLES | 2c 8mm2, ‘oo Mir. | _899.00 Da_| 210 10mm2 “100 Wr. 839.00 i) | 3.5/0 25 mma 4100 Mtr 1509.00 ii) [95/0 50mm2 400 Mtr 1509.00 (iy aextérama 100 Mitr. 7286.00 | [wy acxasmme 100 Mir 7509.00 | 3 bet ARMOURED Single Give XLPE cabio | Single Core 50 roma 100 Mir 59.00 | i)_| Single Core 95 mm2 “100 Mt. 783.00 | 71 KV HLT. XLPE CABLES Single Core 630mm2 400 Mtr, 2236.00 3 x 25mm2 ae 190 Mitr 2012.00 a — Hite [ato | 3Cxe5mm2 100 Mtr 2683.00 30 x 188mm2 Too. | 3384.00 3x 300mm2 400M, | 4472.00 30x 400mma te 100 Mi. 5963.00 4 | UN-ARMOURED COPPER CONTROL CABLE 26 x Amn, i : te 14.00 | 2C x 6mm Mr | 14.00 30x 4mm2 a Mtr 73.00 | 4C x Arama eee Mi, | _13.00 @C xamm2_ = we 7600) Thineiton\ poet Comniorector erection rates new 14518 (2) (1}.docx Page Se wy _| 76 x2.5mm2 ir vi) | 106 x2.6mm2 wer, | @ | HT AERIAL BUNCHED CABLE (ABC) “) [Sex85+35mm2 ~ [190 mtr. [2042.00 iy_| 3¢xa6+70mm2 00 mate 2012.00 | iy) | 8CxS0mm2 + 70mme joo nir. | 2348.00 iw) | Sx7Gmma + 7Omm2 400 Mir 2460.00 w)_| 8x95mm2 + BOmm2 aati 100 Mr 3131.00 [wy _| 30xt60mma * 120mm2 100 tr. 3578.00 vil)__| 3x185mm2 + 1S0mm2 100 Wir 4025.00 vill) | 30x185mm2 + 240mme iz 00 Mir, | 4025.00 5A_| LT AERIAL BUNGHED CABLE (ABC) : i) | 3Cx16+25mm2 : “T1400 ar. | 900.00 i) | 3Cx25+25mm2 4100 Mir. 1100.00 iil) | 30x60+35mm2 FH “oo mir, | 1400.00 iv) | 3¢x95+70mm2 ~__| 100 mer. | 1500.00 v)_| 3ex120+70mm2 100 Bt. 1800.00 6 |[33KV Hi XLPE Cable )_| Si¢ 300mm2 oom. | 2236.00 |i) | SiC 630mm2 00 Mtr. 3019.00 Ti) | 3Cx 95mm2 fi 4100 tat. 3354.00 y)_| 3Cx 120mm2 400 hte 3913.00 wy) [scx 160mm2 ‘oom. |__ 3913.00 vi) | 3Cx 185mm2 100 Mir. 4472.00 vil_| 3/6 800mm2 100 Mir. 590.00 via. | 8/6 400mm2 ce 00 Mir. 7453.00 vip b, | 3/6 400mm2 with trenchiess boring along with road restoration. | per Mi. 580.00 7 | 33 KV Aerial Bunched Cable a D)_| Score x 95+95mm2 3678.00 i)_[ 8 Core X120+150mm2 3801.00 ity [3 CoreX 186+260mma 4248.00 8 _| Making of Cable Joint )_[AT Joint Each | 727.00 [PET seine Each 391.00 |'SUB HEAD- (6) Erection of service connections (excluding energy meter) | 1 | General service connecting with PVC to be tapped off from the existing cable sub-main. i) _| Sewice upto 6 Mtrs. Each 76.00 _ [iy [Service upto 10 Mars Each 412.00 ii)_| Service upto 20 Mis. FE | Each 145.00 w)_[ Service upto 25 Mts Each 207.00 | vv) _| Service upto 30 Mir. eee Each | _268.00 ‘itien\atDuHos\comniie peter erection rates Mew 14528 (2) (1).docx Paget W) _| Service upto 40 Mrs. 335.00 vi)_| Service upto 60 Mirs. - i i 403.00 vil)_| Service upto 60 MiTrs. [488.00 by | Service upio76 Mire. Fe Ht Each 475.00 @ | Industrial / Tube well Service connections to be tapped off from the existing cable sub | main of service or pole. i) _| Service ength unto 5 Mts. |) | Service tength upto 10 mrs. [i _| Service length upto 20 Miss. [Ty _ | Service tenoth upto 25 Mrs. | [iy Service length upto 30 Mire. [¥i_| Service length upto 40 Mrs. | vil) _| Service length upto 60 Mire vill_| Service length upto 60 Mire. | “)_| Service length upto 75 Mis. | x__| Installation of 3 Phase meters in urban areas, Each_| 4) _| Installation of 3 Phase meters in rural areas | each” | “xi _| Installation of Single phase meters in urban areas, Each | ' (ity Tnstllation of single phase meters in rural areas Each | | wiv) installation of LT CT Meter only Each | wv) | Isalation of three Ph. 4 Wire 11 KV feeder meter (BLMS fees 2 _| somplant) of ass 0.88 accuracy | | | [eaten ciee nae tas CLogramaiaucng | can | ease wy [spent ives ie CT psa sara | oy | tan (Tea | installation of single phase NCB Fach 50.00 xix) _| Instatiation of three phase MOB Each 67.00 ‘SUB HEAD-(H) q (| Fig of sret ight racket, wail mounting pote mounting or | egy 323.00 | | hanging type. 7 +— 4 2 | Fiking of Fluorescent tube complet in allrespect onthe pole | Esch | 13400 | ‘SUB HEAD- (I) ot j 7_ | Erection of jumpers and transpositio Each | 2 [Encore cwanamaencrer om eet 2 [papeontera ssapercoemareerd | cane | ston ‘SUB HEAD- (J) ate 17 [Erection of 11 KV CT or PT complete in alirespect “Each | 164.00 | 2 | Erection of 7. CT complete inal respect Each | 123.00 | “3” [ Erection of 6.6, SWITCH cemplete in all repect “Bach | 738.00 41 _| Erection of Meier Box including meter outgoing connector box, connections, instalation of cleats eto. complete in allrespect —_—<<—$$ "Eauldhov\petep\cpytee rego tr evection rates new 14548 (2) (1).docx d Pages Erection of Meter Box to house 20 Nos. of Single Phase | | Meters in accordance with approved design / drawing of Nigam | i) | with separators, inlet and outlet holes per cable, door lock, Each 559.00 | transparent glass cover for Meter Reading ete. (20X1) complete |__| inal respect. Erection of Meter Box to house & Nos. of Singie Phase Meters: im accordance with approved design / drewing of Nigam, in-lt, i) | and out-et holes per cable, transparent glass cover for Meter Each 224.00 Reading, tobe meunted on PCC Poles et (6X 1) compet in a /— Breckon or Weter Bot aie 1 Nos, oT Single Phase Wotare | in accordance with approve design /drewing of Nigam. n-let | | a) | and cutie holes per cable, transparent glass cover for Meter Each 224.00 Reading, to be rounted on PCC Poles ete (4 X 1) complete in all | respect. | SUB HEAD. (K) 7_ | Erection of stool Nem [1 | ViShape X Arm 100xs0x6mm No. 95.00 1.2_| ViShape XArm75x40x6mm_— No. 73.00 4.3. | MS. Channel (X-Arm) 100x50x6im 200mm (for H pole) No 151.00, 1.4 _| MS Channel 75x40x6mm (2200mm) For fuse unit No. 111,00 1.5 | MS Channel T-off 100x50x6 mm 1600mm No. 141.00 1.6 | M.S, Angle 50x60x6mm-3220mm (Bracing 4 pole) No. 105.00 (T7_[MSs. Angle 60.60x6mm-2860mm (Bracing H. Pole) No. | 92.00 1.8 _| M.S. Angle fron 50x60x6mm 2400mm (for earth wire) No. 77.00 1.9_| M.S Angle 50x50x6mm-2200mm (Belting for H-pole) No. 71.00 7.10 _| M.S, Angle 60x50x6mm- 2040mtn (Belting 4 Pole) __No. 66.00 1-11 _| MS fiat for T-off Bracing (600!) 60x6mm No. 16.00 2 | Galvanized Angle and Channel of various size TATA/SAIL | Channel 24 | 4) 100x50mm Ko. Lied 22 | 2) 75x40mm ee z= Kg. 7.00 An 23 lh) $0e80x6mm ae f |e a 24_| 2) 66x65x8mm : Kg. 7.00 [25 [ms Channel {00x60mm SAILITATA kg | 5.00 2.6 _| MS Channel 75x40mm SAILITATA Kg. 5.00 2.7_| MS Angle 60x50x6mm SAIL/TATA _ Kg. 5.00 2,8 _| MS Angle 65x65x6x6mm SAILTATA Kg. 500 | 2.9 | MS fat SOX6mm SAILTATA Kg 500 2.40 _| MS X Plate of Channel 100 x 50 x 6mm, 300mm Long No. 34.00 | 2.11. | MS x Plate of Channel 100 x 50 x 6mm, 460mm Long No. 52.00 « 2.12. | MS X Plate of Channel 75 x 40 x 6mm, 300mm Long [ No. 2.13 | MS X Plate of Channel 75 x 40 x 6mm, 4€0mm Long | No. : 2.14 _ | MS X Plate of Angle 40 x 40 x 6rnm,300mm Long No. 15.00 * F216 FMS X Plate of Angle 40 x 40 x Gram 466mm Long No 73.00. 216 MS Plate of Angle 50x 50 x Sn, 300mm Long No) 20.00, —_— - ‘loss\snnnonioy\cmmteerperse eFection rates new 14518 (2) (1).doex Page 2.AT_[ MS X Plate of Angle 60 x60 x 6mm, 460mm Long Wo. 30.00 2.18 _| MS X Piate of Angle 65 x 65 x 6mm,300mm Long No. 2.19 | MS X Plate of Angle 65x65xtimm,460mm Long No. 3_| Erection of CLAMPS 3.1_| P.G. Clanips for 30/60/80/100/130/150 mm2._ 3.2_| Half Clamps Wt. 1.47 Kg, 3.3_| Full Clamps Wt.2.325 kg. '3.4_| 38 KV Top Brackets /hamper 35 _[ 11 KV Top Bracketshamper ispension Clamp Assembly with eye hook 3.7 _| Dead end clamp Assembly with eye hook 4 | Erection of INSULATORS 41 | U1 V Fin insulator with GL Pin T_Ne. 40.00 42 [11 KVDisc Insulator 45KN (T&C type) No. 22.00 _ 43 | 11 KV Disc. insulator 45 KN. (B&S type) No. 22.00 44 | 11 KV Polymeric Disc Insulator 45KN (with fiting (T&C Type) | No. 16.00 45. | 11KV Polymeric Disc Insulator 45KN (with fiting (B&S Type) | No. 46 [11 KV Polymeric insulator wih G.l. Pin No. Z 4.7_| TIKY Polymeric Composite Hes Insuaior Wo. “ag. | Crxtedge Connector for 02s" Pantner Conductor (Nominal a Avuminum Aree 200 mm’) 49_| 85 KV Pin insulator with Pin Ne | 410 | DisoFiting (F&C type) No 4.41 | Disc Fitting (& &S type) No. | 4.12 | LT Insultor No. 4:13_| Guy insulator No. 4.14 | Single tension fitings for 130/180mm2 ACSR Conductor No. “£45 | Suspension fing for TOMBDmri® ACSR Conductor. We | 3 | Erection of Gi. WIRE 51_| Stay wire 778 SW 7 ko. 6.00 62. | Barbed wire cE at HH Ka. 6.00 83 [61 Ship 2666 mi 0 ie Fo earthing Ton i200 6 | Erection of POWER TEs ; 3.5 / BMVA three phase 50 Hz, 38/3.8 KV Step down, outdoor 64 | QNAN Power Transoer Cate wih al accents No. ea 10 /12.5 MVA three phase &t| Hz, 33/11 KV Step down, outdoor = + 62. | ONAN Power Transformer Complete wit al accessories / No. 405926.00 fitings. | ; “7 action 33 VERS + [1 [BBV VOB, 36 KV, 12508 wih 7000 MVA (TERA TET second) |, 4796.00 | rupturing capacity VOB for outdoor use. eae eee @_| Erection of LA'S 8.4 _| Lightening Arrestor 8 KV No. 52.00 a {C\vteridhn\Detceemmiten opr ke @re@ction rates new 14518 (2) (1).doc GS Page? [22 | 35 kV Lightening Arestor S/Stn. Type 30 KV 10KA Heavy Duty. | _No 291.00 [3 [Erection of 6.0. swiTcr. 7 | “11 RV double throw GO Switch 400A, having Y type blades 8.1 | complete in al respect as por latest Nigam's tech. spac. relevant | No. 1093.00 | _18s and latest amendments. [to Fixing of Nuts & Boits [701 | Nuts Botts off sizes Kg 7.00 Eye Screw Bolts 96/8" if 102 | ww 0.483 Ka No. 4.00 70.3 | U-Bott for suspension ftings Ne. 5.00 41 Erection of 33KVCTs cH 144 33KV CTs = i © 400-200/5-5-5-5A No. 4247.00 (i) 300-15015-5-5-54 No. 1196.00 (i), 200-10015-6-6-54 No. | 1465.00 12 Erection of PTs [2.1 S8KVPTs No. | 87800) 43 _| Erection of POST INSULATOR 13.1 [| 3SKV Postinsulaior [Ne 30.00 44 _| Erection of SPACERS 744_| LT Line spacers a [Ne 00 45 _| Erection of Meter Cover Box - |” Deep Drawn type double door & double comporiment LT CT 48.4 | Three Phase Metering Box for DT meter as per Nigam's Tech, No. 232.00 Spec. 46. | Erection of C&R Panel 7 5, | S3KV CBR panel 24 VDC Operated suitable for controling 16-1 | Single TiFs with all accessories. Heit NM en G7 _ | Erection of ISOLATOR 47.4 | 36 KV isolator (630 AMPS) No. 2185.00 48 _| Erection of L&E Switch | 76.1 | 36 KV isolator cum earth switch eee No. 2745.00 (49_ [Erection of 14 KV_6 Panel Board | 12. KV 8 panel boards 24v DC operated consisting of folowing | 49.1 | QutGoing Panel eNO Set 5246.00 LC Panel No. Peete i Capacitor Panel_= __#No. ae | ~ go | Erection of 33 KV STEEL STRUCTURE Galvanized (204 | erste LATE Ne [4.00 202 | LAs/Post insulators a No. 379.00 20.3 | Isolator/L& E Switch |e. 1430.00 | 459.00 204 | 11 KVNCT No. — Tyumainniorikeyconeites vere ection rates new 14528 (2) (1) dock Page [21 | Erection of Battery & Battory Charger a | NkCd Alkaline Batteries (Partial recombination type) with | att | charger for 33/1 KV & 66/17 KY SISin. As per Nigam’s tech Set 7308.00 | Spec, relevant ISS wit latest amendments | us ee ESE ele _| | Erection of HT APFC Parl 12 KV, 4 Step with enclosures, Relay, Vacuum contractor, | 22. | Reactor 0.2% S.R, HTHRG, Fuse 63/100 Amp 47KV all fittings, Panel, Busbar, Post Insulator, Structure, Elect Consumable etc. and all Acc reqd. “[o Rating 3600 KVAR of [Ne 7697700 {i Rating 3000 KVAR No. | 61386. ~[Gip Rating 2400 KVAR No. 60286.00 ~"T Capacitor Celis 200 KVAR No. 977.00 Capacitor Cals 400 KVAR No. 4719.00 Erection of MISCELLENEOUS MATERIALS 2ai_| Transformer plat form complete with clamp No. 3400 Toso | 11 KV Single Pole mountes O/AB switch with operating handle | 232 | ads No. 640.00 233 | Phase plate for each phase set of 3 (on each H-Pole & 4-Pole | Set 7.00 aa Danger Pate Enameled with mp dN sa | 23.5 | Number Plate with Clamp No. | 9.00 [236 |o-straps z a No 300 ['23.7_| insuieted connectors No. 2.00 LT. Distribution box (seelable with lock facility) suitable for 10 f a9 | No. Gonsumers. 2mm CRA sheet box, Bus bare fr foad a8. | yg ee -2 | per 25 KVA DTiFe only wit holes for incoming cable and /G ; | Cable with cubber glanas 259 | Earth Mal for switch yard Ko 400 [2320 | Eating of 39K ish Win ath 8 Eating pte ne | S860 28.11. LT Distribution pane! board for 33 KV SISin complet. No. 2512.00 [az Pipe 250 ma an or TG ebay ha ie recente “| Li Fuse Unit Board for use on Os from 25,63,100 & 200 KVA 23.13 | bistibution Transformer ee i fet 24 _| Erection 14 KV Vacuum interrupters 7 24.1 | Model WL-34595 M3 fos. 1564.00 242 | Model VG-2 Nos. 1673.00 243 | Model WL-38378 MS# iz 7 Nos. 713.00 | (aaa | Medel Vi-35469 60 Nos | 1564.00 NEW ADDITIONS 7 _[ Insulated Piercing Connector (PC) peereeaTe ‘750-160 samm 7 a Thi 46 95 74 - 60 corm Each | 8.00. 2._| Suspension clamp with braiket (NF type] [each |_ 20.00 B 3__| Mid Span Joints: rl ‘95 eqmih 1_Each | _8.00 ——_— ‘anshaeshioy\Gomimicerepotor erection rates new 14518 (2) (1).docx Page? Seqnm z [Each 7.00 25 sqmm is = | Each 7.00 Dead end Clamp for bare messenger with hook bolt through Pole, 16-95 sqm f Each | ___ 26.00 Bi-metallic PG clamp Cu/Al with cover —___ “famm dia, Rod - $5 sqm Al cable Each 73.00 "Anchoring / Dead end clamp for 6/3 SWG (4.877 -4.064 sqmam | 6 | Gsu Tension clamp ; arm) ach sooo | 7 [SS strap with adjustable screw (for clamping of amour for 25, 60. |e, agate 95 sqmmn) & support GSL / jubilee clamp 7 i @ | Ineulation Mastic Tape (2 inch x 10.) Each 8.00. 9__| Dead end clamp for armoured cable woo — i)_ | 25-96 sqmm Each 27.00, 10 poe clamp for 2C- 10 sqmm FIVC cable with strap, buckle & Each 15.00 a | {at [nsutated Bimetalic hige! Thimive i is SeEEEEEEE (185 sqmm Each_| 5.00 12 | LT Fuse box- SMC with pole clamp (FT solneh 18 th inc Each 32.00 | 13 | SS cable ties releasable ARC =~ i) [aia=200mm 7 “Each os il)_| dia 250 mm He Each 0.39 on items : a aa" [33 KV indoor VCB = z [Each 7000.00 a5 [33 KV LBS 33/0.400 KV [Each 2000.00 36 | 330.400 KV copper wound, WOKVADT [Each 6400.00 a7 |PAtypo monopole [per unit_ | 784080.06 18 | PBtype monopole. __ a er unit | __§47842.00 19 | PC type monopole ‘perunit | 625692.00 20 | PD type monopole [perunit | 761696.00— 24V DC Ni-Cd alkaline battery (partial recombination type) with 21 | Siaeprer sorte cart A Sunisin " perunt | 4073.00 | per {22 | ope Pipe a6omm2 HH meter 650,00 33_| Muffin of PCC poles 177, | S meter long PCC Pole [25 m Below tie ground and 0.3m above the LMT eround) per Pole 826.00 1 gy | Hhieter ong PCE Pole (8m Below the ground and 0.3 m above the | ground) corer eae te per pole 1408.00 Note: 41. The new erection rates of all the aforementioned items have been ascertained by the committee keeping in view various aspects i.e. Consumér Price Index, existirtg erection rates, rates finalized by the committee in'2015 etc. as mention in the ‘Teference drawn’ column of Annexure- 2. The above rates are inclusive of al axes, F&l FOR destination 3. The steel items used should be of SAIUTATA make only. The rates of stect febricated items are inclusive of painting (Red Oxide + Aluminium paints of Asian/Nerolac/Berger make), 4, The rates of fabrication of steel items shall be R.15/- kg (Inclusive of transportation charges). 5. The tates of galvanizing of steel items shall be Re.19/- kg for preparation of estimates, 6. Before preparation of estimates, the below mentioned aspecte/biurcation of rates of various items may also be taken into account. Detail of various aspects to be taken into account while preparation of estimates:- Sa ‘Csardhav\Desitee\ craze potter erection rates new 14518 (2) (1).docx \ age 10 L |. Work in Hilly, Sandy & Expensive Localities. a) An addition of 20% over and above the schedule of labour rates may be allowed for the jobs to be executed in hilly areas. 'b) in difficult terrains not easily approachable by road and in sandy area an addition of 10% over and above the schedule of labour rates may be allowed. ) Delhi, Faridabad, Ballabgrah, Gurgaon and Panchkula are considered an relatively expensive areas. An addition of 10% over and above the schedule of labour rates may be' allowed in these localities. 2). Dismantlement of works: a) Wherever dismantiement of lines/substations is necessitated due to augmentation ‘or otherwise a regular estimate of dismantlement should be prepared and in estimate a provision of labour at 50% of the schedule for erection may be made. 3) Transportation of Poles, Transformer & Conductor:- For lifting/transportation of poles/transportation including loading/unloading field labour charges are proposed as under. The rates applicable shall be as per already negotiated rates finalized in EOI for 33kV & TAY works 4) Formula for calculating the supply rate of steel item:- The fabrication of steel items shall be Rs.15 per Kg including painting (Red oxide + Aluminium paints of Asian/Nerolac/Berger make) and inclusive of Transportation charges, 5) The rates of galvanizing of the stee! items shall be Rs. 13/- per kg. in case the galvanized material for preparation of the estimates. 6) The road restoration charges (Broken during erection of pole) shall be Rs. 525 per pole. However number of such poles shall be mentioned in the estimated clearly. 7) Trenchless laying of HDPE and PLB-HDPE pipe by using HDD method Rs. 715 per meter including laying of cable, Digging & refilling of pits etc. 8) Eréction charges of Rs 798.00/- in sub head ~ (B) 4 of HT PCC Single Pole 9 Mtrs tong include the following i.e. i) ‘Hole in ground = Rs. 179.54/- fi) Fixing of X-arms, knee bracing, poles caps/top = Rs. 303.29/- hamper and pin insulator etc. lil) Erection of pole as site = Rs. 199.54/- iv) _ Fixing barbed wire, danger plate and bird guards etc. =Rs, 115,72/- Total = Rs. 798.00- — Chonistmibowntanentesrnonte erection rates new 14538 (2) (1) docx Page It oO 9) Erection charges of Rs. 898/- in sub head - (A) 6 of HT PCC Single Pole 11 Mtrs long include the following i.e. s, 120.56/- 8. 425.78/- i) Hole in ground ii) Fixing of X-arms, knee bracing, poles caps/top hamper and pin insulator etc. ill) Erection of pole as site = Rs. 277.02/- iv) _ Fixing barbed wire, danger plate and bird guards ete. = Rs. 74.39/- Total = Rs. 897.75/- (Say Rs. 898/-) 40). Erection charges of Rs 2683/- in sub head — (c) 2 of 25 to 63 KVA pole mounting substation without poles include the following i.e. i). Erection of plat from set = Rs. 100.00/- ii). Installation of Transformer = Rs. 567.48/- ji), Erection of GO Switch with Fuses = Rs. 743.50/- iv). Erection of LT Switch with fittings = Rs. 203.48/- v). a. Erection of T/F Earthing -2 nos. = Rs, 333.18/- b, Digging and filing of 20" deep pits -2 nos. = Rs, 306.36/- vi). Erection of jumper set — 2 nos. = Rs, 131.93/- vil).Erection of cable with fittings and connecting = Rs, 297.40/- the same to Transformer Total = Rs, 2683.32/- (Say Rs. 2683/-) 44). Erection charges of Rs 3078/- in sub head — (c) 1 of 100 to 200 KVA pole mounting substation without poles include the following i.e. i), Erection of plate from set = Rs. 100.00/- i), Installation of Transformer = Rs. 664,75/- i), Erection of GO Switch with Fuses = Rs, 851,95/- iv). Erection of LT Switch with fittings = Rs, 233.68/- v).a. Erection of T/F Earthing -2 nos. = Rs. 362.36/- b. Digging and filling of 20' deep pits -2 nos. = Rs, 349.95)- vi). Erection of jumper set - 2 nos. =Rs. 150.93/- d vii). Erection of cable with fittings and connecting = Rs. 341.00/- the same to Transformer Total = Rs. 3074.64/- (Say Rs. 3075/-) 12). Erection charges of Rs 1258/- in sub head — (c) 6 of 200 to 500 KVA on plinth complete in all respect, include the following i. i) Placing of transformer on plinth = Rs. 536.67/- i) Earthing for transformer -2 Nos. = Rs. 640.64/- iti) Making cennection to transformer = Rs. 80.50/- Total = Rs.1257.84/- (Say Rs. 1258/-) 43). Erection charges of Rs 1509/- in sub head - (c) 7 of 500 to 1000 KVA on plinth complete in all respect, include the following ie. i) Placing of transformer on plinth = Rs. 788.23/- ) Earthing for transformer- 2 Nos. = Rs, 640.64/- Making connection to transformer = Rs. 80.50/- Total = Rs. 1509.37/- {Say Rs. 1509/-) 14). Erection charges of Rs 6708/- in sub head —(c) 8 of 11 KV VCB complete in all respect, include the following Le. i) Placing of VCB = Rs. 4391.70/- tly Making connection to earthing =Rs. 80.50/- ii) Making connection to the VCB = Rs. 2236.10/- Total = Rs. 6708.30- (Say Rs. 6708) i ‘Cluses\eb\ dette reports erection rates new 14518 (2) (1).cdocx age 13 , 48). Erection charges of Rs 8/- Mtr in sub head — (F) 1 (i) of LT underground cables of sizes 2/c 6mm sq., 10mm sq. Include the foll Db Digging of trench il) Spreading of sand iil) Laying of cablés, Placing of bricks iw) Back filing o) Total « armoured lowing ie. = Rs. 3.47/- =Rs 0.78/- =Rs. 2.24/- =Rs. 1.12/- =Rs. 1.12/- = Rs. 8.39/- (Say Rs. 8/-) 16). Erection charges of Rs 13/- Mtr in sub head ~ (F) 1 (iv) of LT armoured underground cables of sizes 4/c 16mm sq. include the following i.e. ft Digging of trench i) Spreading of sand iti) Laying of cables iv) Placing of bricks vy Back filling Total 17). Erection charges of Rs 15/- Mtr in sub head — (F) 1 (ii, = Rs. 4.81/- =Rs 1.20/- = Rs. 3.43/- =Rs.1.71/- =Rs.4.71/- = Rs. 12.86/- (Say Rs. 13/-) & vy) of LT armoured underground cables of sizes 3.5/c 25mm2 & S0mm2, 4/C 25mm2 sq. include the following i.e. » Digging of trerich = Rs. 8.63/- iy Spreading of sand =Rs 1.41/- ii) Laying of cables = Rs. 4.02- Ww) Placing of bricks = Rs. 2.01- y) Back filing = Rs. 201+ Total = Rs. 15.09/- (Say Rs. 15/-) pais Superintending Engineer/P&D, For CE/PD&C, DHBVN Hisar _—_—_—_——— Paget ‘\vwer\br\beopleommites pone erection rates new 14518 (2) (1).docx Seo

You might also like