Application Scenarios
Cooling System
Integrated cooling unit
provides efficient thermal
management for closed aisle
space.
Equipment Savings
Pre-engineered, integrated
thermal management, and
power distribution
Energy Savings
Requires less space and
minimum site preparation
through integrated design
Closed
Cold Aisle
Applicable to room size > 20m²
Closed
Hot Aisle
Applicable to room size at about 20m²
SmartRow™ vs Traditional Computer Room Build
Features SmartRow™
Industry leading design. All products integrated in the system-thermal management,
Complete, Integrated
monitoring, racks, optional UPS/Power Distribution and rack PDUs-work together to optimize
Infrastructure
capacity, efficiency and availability.
Employs best practices known to work well in top-performing data centers:
Hot aisle / cold aisle separation
High availability, high efficiency UPS
Incorporate Industry Highest efficiency cooling
Best Practices Space-saving, minimal footprint
Modularity for flexibility and easier expansion
Integrated monitoring and control for efficiency in planning and management
Reliable local service
Lower Capital Achieve greater savings compare to traditional build with dedicated cooling, raised floor and
Expense other conventional data center requirements.
Lower Operating
Better PUE reduces energy cost by more than 30%
Expense
Compact Footprint Integrated design occupies less floor space and reduces costs.
Simplified Project Network of local data center experts and service teams make ordering, installing and
Management servicing the SmartRow solution easy.
2-4 racks, 12 kW cooling capacity with redundancy options; ability to scale power, cooling
Flexibility
and monitoring management all within existing architecture
Monitoring and Integrated monitoring and alarm systems work together to provide greater control over
Management the IT environment.
Features Traditional Computer Room
Complete, Integrated Multiple and varying infrastructure components must be ordered and installed separately
Infrastructure which can result to system incompatibility resulting to inefficiency.
Incorporate Industry Infrastructure components may not be designed and configured for best practices to optimize
Best Practices performance.
Lower Capital Additions or overhaul of room-level power, cooling and distribution needed to accomodate
Expense more IT equipment
Lower Operating Independent cooling equipment may be less efficient because the entire room temperature and
Expense humidity must be managed
Perimeter cooling and other infrastructure may require greater space utilization. Cooling
Compact Footprint will require more airflow making it less efficient; power distribution will require multiple
distribution panels
Installation is complex with cascading requirements, longer timeframes, and multiple outside
Quick Installation
technicians required
Simplified Project
Service and support from multiple vendors may be complicated
Management
Flexibility Difficult to change airflow or add air capacity, as well as to add power capacity
Monitoring and Monitoring and management are available, but may not be integrated across infrastructure
Management components as turn-key solution.
Intelligent Monitoring Platform
with Remote Access for Management
1 4
1
2 5
2 3
4
3 6
Real-time monitoring
and status display
Alarm setting and
notification
Facility equipment
remote management
Report and trending
analysis
Instant configuration
software package
(available for 4 standard
scenarios)
Scalable platform for
business growth
Manage Environments and
Security of Data Center with RDU-A G2
The Liebert® RDU-A G2 is an infrastructure management solution from Emerson Network Power that allows data center
administrators to manage environmental conditions (i.e. temperature and humidity, leak, smoke, vibrations and digital
inputs and outputs.) It is also capable of monitoring infrastructure appliances such as UPS, Thermal Management units,
generator sets, etc. The Liebert® RDU-A G2 is equipped with a built-in web server, eliminating the need to perform a
software installation.
Console Port
USB LEGEND:
Power Input 1 Power Input 2 n Modbus 485 Com Port
100~240VAC USB Camera / 100~240VAC n Environmental Sensor Port
Modem Port n Contact Closure Output Port
n Ethernet and SNMP Port
Power
Power load 20kVA
Rate output power 20KVA/18KW Closed Cold Aisle | Room size > 20m²
Thermal Management
Cooling type Air-cooled / DX. Thermal Management
Refrigerant R22
Monitoring
Closed Hot Aisle | Room size at about 20m²
Platform unit RDU-A G2
System Operation
Indoor: 0°C ~ 40°C / 30%RH ~ 80%RH
Working environmental Outdoor: standard model, -15°C ~
+45°C; Lee-Temp model, -34°C ~ +45°C
SmartRow™ 1 + 2 (One cooling cabinet + two IT cabinets)
Specification Cold Aisle Closed Hot Aisle Closed
More options:
1. Cabinet Solution: Cabinet in 2000mm(42U) x 800mm x 1100mm is available for networking
application; the conventional accessories like blanking panels, cable management , shelves are also
available with standard offering
2. Power Solution: Redundancy power system solution, battery and PDUs are available with standard
offering
3. Monitoring Solution: more options on environmental sensors are available. For those SmartRow
deployed in distributed location, a central facility management platform–RDU-M is available with
more sophisticated management functions
Emerson Network Power Asia
Australia Pakistan
T: 1800-065345 T: 92-42-36622526 to 28
F: 61-2-97438737 F: 92-42-36622530
Indonesia Philippines
T: 62-21-2513003 T: 63-2-7207400
F: 62-21-2510622 F: 63-2-6203693
Japan Singapore
T: 81-3-54038564 T: 65-64672211
F: 81-3-54032919 F: 65-64670130
Korea Thailand
T: 82-2-34831500 T: 66-2-6178260
F: 82-2-5927886 F: 66-2-6178277 to 78
Malaysia Vietnam
T: 603-78845000 T: 84-4-37628908
F: 603-78845188 F: 84-4-37628909
New Zealand
T: 64-3-3392060
F: 64-3-3392063
Stay connected:
Marketing.ap@emerson.com
www.EmersonNetworkPower.Asia