You are on page 1of 2

Service Mode Options Amber LED Codes Accessing the Service Mode Menu

The amber LED allows you to pinpoint a fault that may have occurred on one of the A Quick press of the Yellow (mode) button will take you into the Service Mode
modules of the coin manager. These types of fault can be rectified at the machine and menus. The display will change to show the available option available. (see picture
can be for example; a coin jam, dirt built up on a particular sensor or cassette below).
Press Button Sequence Description / Action removed etc. The Coin Manager also displays the fault on it’s display. Service Mode Menu
(Options Available)
Quick Reference Card V 1.18 A PAR coin tubes / Insert coins if asked Amber
Coin Manager Maintenance LED Codes
Flashes
Understanding the User Interface Keypad Custom tube cassette teach / Follow
D 1X Discriminator error
2 Instruction

Predefined tube cassette teach 2X Accept gate error


D

1 Separator module top level sensor


3X
Tube cassette error

LED Light Codes 4X Dispenser module error Flashing Quick Press


Mode Button
3 4 The 3 LEDs fitted on the Coin Manager provides up to the minute status
5 information. Please refer to the table below for more details. 5X Low on change
Accessing the Set-up Mode Menu
Red, Amber, Green
On Coin Manager OK
☺ Selecting a Predefined Cassette To access the Set-up Mode menus, press and hold the yellow (mode) button for
approximately 2 seconds. The display will change to show the available options
1 3 LEDs
to going solid green). Coin Manager OK ☺
Cycles Normal power up / Reset or Accept (prior The Coin Manager has stored in memory a selection of predefined tube cassettes. available (see picture below).
X5 Each cassette allows a different payout option to be selected. (See table below). Press Scroll UP
2 A to E Dispense coins & navigate through menus Set-up Mode Menu
Using the buttons on the keypad, press the button sequence as shown on the table To view Menu List
(Options Available)
Coin accepted/ Rejected (Refer to green or refer to the tube cassettes front label for the button sequence. Once the Coin
3 Display (LCD) Menu information & warning display Blinks off Manager has accepted the code, the chosen cassette will be set.
LED Codes on the next page)
Coin Manager in Menu mode (Refer to
4 Mode Button Access service & set-up menus Flashing To set a Predefined cassette :Press D followed by the key code
green LED Codes)

5 Service Connector CPM Compatible On Coin Manager inhibited by VMC Key Code Tube A Tube B Tube C Tube D Tube E
AA 10c 5c 25c 25c 5c
Coin Manager requires attention (Refer AB 10c 5c 25c $1 5c
Flashing
to Amber LED Codes) BA 25c 5c 25c 25c 25c
General Keypad Operation Off
No Power to Coin Manager . Check Power
harnesses are connected & ensure power is
BB
CC
10c 5c 10c 25c 5c
Custom cassette 1 - defined in factory or by service tool
When the coin manager is in the idle state, the blue buttons can be used to switched ON. CD Custom cassette 2 - define yourself using cassette teach
Flashing Press & Hold
dispense coins from the tubes. If however, the mode button is pressed beforehand, DAC 25c 5c $1 $1 25c
Coin Manager Faulty Mode Button
these buttons are used to navigate through the service & set-up menu options. Alternating DCA 25c 10c 25c $1 5c
(Send unit in for repair)
DCB 25c 10c $1 $1 5c
Keypad General Operation LANGUAGE
DCC 25c 10c 25c 25c 5c
Dispense coin D DCD 5c 10c 10c 10c 5c
A Dispense coin A D
Green LED Codes DCE 10c 10c 10c 10c 5c TEST
After Pressing
B Dispense Coin B E Dispense coin E
Mode Button
LED Codes for when in Set-up or Service Mode Cassette viewed
Tube from above ERROR LOG
Slow Flash Coin manager is in Set-up Mode/ E
C Dispense Coin C Mode
Service
GENERAL
The mode button can be used to access the two configuration modes available. Fast Flash Message Available
Service Mode and Set-up mode. Tube Tube Tube Tube
Service Mode: gives access to the most frequently used product configuration A B C D AUDIT CONFIG
Press A B C Code to go
options. (See Service Mode Options)
Coin Accepted from Basic to Advanced Menu.
Set-up Mode: gives access to general product configuration options that are Coin Discrimination LED Codes
/ Rejected The Coin Manager can also be custom configured by removing any of the coin COIN CONFIG
required when setting up your Coin Manager. (See Set-up Mode Options)
Inserted coin was accepted tubes and replacing them with another denomination tube. But there are
1 X Blink restrictions:
Mode Button Operation Always include at least one 5c tube in all custom configured cassettes. ADVANCED VENDOR OPTIONS Press D
Inserted coin was rejected - unknown to go UP
2 X Blink Do not place the $1 tube in tube A or B position. a menu level.
Press Once to access Service Mode menu (not recognized by discriminator) Do not place the 25 cent tube in tube B position.
ERROR LOG CHANGE MGMT
Coin rejected/inhibited by machine or Do not place the 10 cent tube in tube E position.
Press & Hold for 2 seconds to access Set-up Mode menu 3 X Blink Coin Manager program settings Press E to go Down
a menu level.
Press twice to view Coin Manager audit data. Tube # & Max Fill ($) Manual Fill($) Position PAR SETUP PAR SETUP
Ensure tube cassette is fitted. Coin Base (by Coin (do not fill In
Remove tube cassette and press twice to Park Color Manager) more than) cassette MESSAGES* MESSAGES* Menu Starts Here
the dispenser arms.
5c 22 Red 77 ($3.85) 87 ($4.35) A,B,C,D,E
* If available * If available
10c 20 White 115 ($11.50) 127 ($12.70) A,B,C,D
25c 25 Black 84 ($21.00) 96 ($24.00) A,C,D,E BASIC ADVANCED
MEI CASHFLOWTM 7512 Series Quick Ref. Guide 2008 - Rev G5 $1 27 Blue 69 ($69.00) 81 ($81.00) C,D,E
MENU MENU
Display - Symbol Indicators
Advanced Mode Menus AUDIT CONFIGURATION Basic Mode Menus During the coin manager programming or normal operation, icons may be shown
on the display. These icons will indicate if the coin manager requires any attention
This chart shows a detailed structure of the Advanced Set-up Menu. This chart shows a detailed structure of the Basic Set-up Menu. or will assist you in selecting a particular program mode.
Setup Machine ID
Reset audit
PAR SETUP

Ir POD password No Change


Select Style PAR to Value
reset
PAR to Level
Press & Hold Report type PAR to Auto
Printer
Use Value/Level From Snapshot
For 2 Seconds Basic Symbol Meaning Comment
Interims Current Settings
PAR Value/Level Edit Value/Level
Free Vends Menu Navigation Move Cursor to the Right
Card vends
PAR SETUP Tube Fill Level Fill to PAR
Fill to Max Menu Navigation Move Cursor to the Left
Select Style PAR to Value
PAR to Level GENERAL
PAR to Auto Menu Navigation Move Up through Menu
Use Value/Level From Snapshot Calibrate tubes Calibrate ERROR
Current Settings Accept Coins US or CAN or Both LOG Menu Navigation Move Down through Menu
PAR Value/Level Edit Value/Level Cleanme level Level 0% to 100%
Settings Save / Restore View Last 1 to 10
Tube Fill Level Fill to PAR Reset Reset error logs? Message Waiting* A message has been left for you to read
Fill to Max

ERROR Smiley face Coin Manager is OK


LOG
TEST
CHANGE View Last 1 to 10 Average face Coin Manager requires assistance
Testing % Done
MANAGEMENT Reset Reset error logs?

Tube Fill Level Max Capacity / Fill to Par


Sad face Coin Manager requires replacing
Payout Mix Large/Small/Change Machine ADVANCED
TEST
Press A B C Check Discriminator for coin jam
Module Coin Sensors Takes You to Par Setup Maintenance required
or foreign material
Accept gate
VENDER Gate sensor
OPTIONS Separator
Top Check Accept gate for coin jam or
MDB options Maintenance required
Right foreign material
Optimize change Edit / Off / On
Left
Level Level 2 / Level 3
Cassette
Coin Counts as CF 1234 / TRC0004
Dispenser Check Seperator coin level sensors for
Par coins Hide / Report Maintenance required
Temperature-Calibrate coin jam or foreign material
Coin scaling Edit (1 to 255) or Automatic
0-50.0C
Decimal point Edit (0 to 5)
Comms
Country Edit country code
Audit
MDB peripheral Check Dispenser for coin jam or foreign
VMC Maintenance required
material
Connectivity Testing % done
COIN CONFIGURATION Info SW & HW rev

Token teach select location *Message Waiting Icon:- If there is a message waiting to be read, the
Security Hi acceptance LANGUAGE envelope icon will be shown on the display. This message is displayed
Hi security when/if the coin manager has detected that it can be optimized for
Language Not set better performance e.g. better tube combinations, payout algorithm etc. thus
Coin setup Coin 1 to 32 English US improving sales.
Chan setup Channel 1 to 32 French CN
Exchange Rate Edit US/CAN Spanish US Reading the Message: Access the setup menu in the normal way (the display
Alarm timeout Alarm time English UK will show the word "messages") and follow the instructions on the display.
Edit / 0 - 1275 secs Dutch The messages will be displayed in the order of; last in first out.
French EU The coin manager can store up to four messages at a time, when these have
Netherlands been read, you can delete them by going through to the delete messages menu.
Spanish EU
Portugues
Italian

You might also like