Professional Documents
Culture Documents
1250-2000reozm Reozd G6119
1250-2000reozm Reozd G6119
Hinged and
removable doors for
ease of servicing
Door hold backs provide
positive door positioning
during wind gusts
Fixed air inlet louvers
sized for maximum
radiator cooling air flow Recessed and lockable
door handles minimize
potential damage
Rubber sealed access doors
prevent water infiltration and
minimize noise
Hinged and
removable doors for
ease of servicing
Door hold backs provide
positive door positioning
during wind gusts
Acoustic insulation
repels moisture
absorption Recessed and lockable
door handles minimize
potential damage
Rubber sealed access doors
prevent water infiltration and
minimize noise Acoustic insulation
meeting UL 94 HF1
Air outlet internal plenum
flammability classification
lined with acoustic
insulation
Space
heater
Disconnect
switch
Step- down transformer
mounted on plate in the
electrical stub-up
Emergency Lights
- Emergency Lights. Mounted inside the enclosure with
batteries, qty. 2.
Removable Electrical Overflow to main tank Additional fitting Fuel fill with Fuel Normal
end channel stub-up area (with user-supplied for optional lockable cap and level vent
open to bottom day tank accessory 203 mm (8 in.) riser gauge
D Extended operation. Optional tank capacities for multiple - Fill pipe extension to within 152 mm (6 in.) of bottom of fuel
hour requirements. tank
D UL listed. Secondary containment generator set base tank - 18.9 L (5 gallon) spill containment, Florida Dept. of
meeting UL 142 requirements. Environmental Protection (FDEP) File No. EQ-345 approved
D NFPA compliant. Designed to comply with the installation - 18.9 L (5 gallon) spill containment with 95% shutoff, Florida
standards of NFPA 30 and NFPA 37. Dept. of Environmental Protection (FDEP) File No.
D Integral external lift lugs. Enables crane with spreader-bar EQ-345/EQ-257 approved
lifting of the complete package (empty tank, mounted
generator set, and enclosure) to ensure safety. - 18.9 L (5 gallon) spill containment fill to within 152 mm
D Emergency pressure relief vents. Vents ensure adequate (6 in.) of bottom of fuel tank
venting of inner and outer tank under extreme pressure
Fuel Supply Options
and/or emergency conditions.
D Normal vent with cap. Vent is raised above lockable fuel fill. - Fire safety valve (installed on fuel supply line)
D Low fuel level switch. Annunciates a 50% low fuel level - Ball valve (installed on fuel supply line)
condition at generator set control.
D Leak detection switch. Annunciates a contained primary tank High Fuel Level Switch
fuel leak condition at generator set control.
- High fuel level switch
D Electrical stub-up.
- High fuel level switch, Florida Dept. of Environmental
Protection (FDEP) File No. EQ-682 approved
Subbase Fuel Tank Option
- ULC-S601 tank listing Normal Vent Options
- 3.7 m (12 ft.) above grade (without spill containment)
State Code Subbase Fuel Tank Options - 3.7 m (12 ft.) above grade (with spill containment)
Bottom Clearance/Coating Tank Marking Options
- I-beams, provides 106 mm (4.2 in.) of ground clearance - Decal, Combustible Liquids - Keep Fire Away (qty. 2)
- Epoxy mastic coating - Decal, NFPA 704 identification (qty. 2)
Fuel in Basin Options - Decal, tank number and safe fuel fill height (qty. 2)
- Fuel in basin switch, Florida Dept. of Environmental - Decal, tank number and safe fuel fill height, NFPA 704
Protection (FDEP) File No. EQ-682 approved identification
DISTRIBUTED BY: