Flange
Class 300 Class 150
Nominal Pilot Pilot
Size Range Rating Range Rating Range
Product inches psi psi psi psi
Configuration DN bar bar bar bar
12 – 16 300 5 – 30 250 5 – 30
867–43T-PS
DN300 – DN400 21 0.3 – 2 16 0.3 – 2
30.93 8614 Rev D Updated 09/2019 © 2019 Victaulic Company. All rights reserved.
victaulic.com 2
victaulic.com
2.0 CERTIFICATION/LISTINGS
NOTE
• Refer to Available Sizes/Pressure Ratings Table in section 1.1 for additional details.
Visual Indicator
External Bolts
Limit Switch
Diaphragm Assembly
5 Flanged end connection available in all materials, grooved and threaded available in ductile iron only.
6 Hastelloy is a registered trademark of Haynes International.
7 Monel is a registered trademark of Special Metals Corporation.
30.93 8614 Rev D Updated 09/2019 © 2019 Victaulic Company. All rights reserved.
victaulic.com 3
victaulic.com
4.0 DIMENSIONS
Series 867-42T, 867-43T, 867-43T-PS
a
a a
W2
H a
a H
H
RF W1 RT
RG ad d d
LG d a
LF LT
30.93 8614 Rev D Updated 09/2019 © 2019 Victaulic Company. All rights reserved.
victaulic.com 4
victaulic.com
5.0 PERFORMANCE
Relief Valve Sizing
Series 867-42T
Systems must be designed with adequate downstream pressure relief to protect components from over pressurization
during pump operation.
To maintain FM Approvals, minimum ½"/15mm pressure relief must be provided downstream of all pressure reducing
valves.
Flow Chart
Series 867-42T, 867-43T, 867-43T-PS
15 1.0
0.9
0.8
10 0.7
9 0.6
8 0.5
7
6 0.4
5
0.3
4
PRESSURE DROP – PSI / Bar
3 0.2
m
m
m
mm
10" mm
m
m
0m
00m
m
50m
2
"/40
0m
0m
"/73
00
/25
4"/1
8"/2
6"/1
2"/5
3"/8
1½
2½
0.1
0.09
0.08
1 0.07
0.9 0.06
0.8 0.05
0.7
0.6 0.04
0.5
0.03
0.4
0.3 0.02
0.2
0.1 0.01
20 30 40 50 70 100 200 300 400 500 700 1000 2000 3000 4000 5000 7000 10000 15000
5 10 20 30 40 50 100 200 300 400 500 1000 2000 3000
FLOW RATE – GPM / m3/h
NOTE
• For sizes greater than 10"/DN250, please use information in Section 5.2.
30.93 8614 Rev D Updated 09/2019 © 2019 Victaulic Company. All rights reserved.
victaulic.com 5
victaulic.com
psi bar
15 1
14
13 0.9
12
0.8
11
10 0.7
Pressure Loss
1.5" 2" 2.5" 3" 4" 6" 8" 10" 12" 14" 16"
9
0.6
0.5
7
6
0.4
5
0.3
4
3 0.2
20 30 40 50 60 80 100 200 300 400 500 700 1000 2000 3000 m3/h
50 70 100 200 300 400 500 700 1000 2000 3000 4000 7000 10000 15000 gpm
Flow Rate
5.1 PERFORMANCE
Must be installed with a minimum of ½" relief valve for FM Approved installations
Discharge Chart
Series 867-43T
NOTE
• For sizes greater than 10" please use information in Section 5.2.
30.93 8614 Rev D Updated 09/2019 © 2019 Victaulic Company. All rights reserved.
victaulic.com 6
victaulic.com
5.2 PERFORMANCE
Series 867-42T, 867-43T-PS
CV Values:
CV values for flow of water at +60°F/+16°C through a fully open valve are shown in the table below.
Formulas for CV and KV values
Where:
Frictional Resistance
The chart below expresses the frictional resistance of Victaulic Series 867-42T, 867-43T, 867-43T-PS Pressure
Reducing and Pressure Relief Valves in equivalent feet of straight pipe.
30.93 8614 Rev D Updated 09/2019 © 2019 Victaulic Company. All rights reserved.
victaulic.com 7
victaulic.com
6.0 NOTIFICATIONS
WARNING
• Read and understand all instructions before attempting to install any Victaulic
products.
• Always verify that the piping system has been completely depressurized and
drained immediately prior to installation, removal, adjustment, or maintenance of
any Victaulic products.
• Wear safety glasses, hardhat, and foot protection.
Failure to follow these instructions could result in death or serious personal injury
and property damage.
• These products shall be used only in fire protection systems that are designed and installed in accordance with current, applicable
National Fire Protection Association (NFPA 13, 13D, 13R, etc.) standards, or equivalent standards, and in accordance with applicable
building and fire codes. These standards and codes contain important information regarding protection of systems from freezing
temperatures, corrosion, mechanical damage, etc.
• The installer shall understand the use of this product and why it was specified for the particular application.
• The installer shall understand common industry safety standards and potential consequences of improper product installation.
• It is the system designer's responsibility to verify suitability of materials for use with the intended fluid media within the piping system
and external environment.
• The material specifier shall evaluate the effect of chemical composition, pH level, operating temperature, chloride level, oxygen level,
and flow rate on materials to confirm system life will be acceptable for the intended service.
Failure to follow installation requirements and local and national codes and standards could compromise system integrity or cause
system failure, resulting in death or serious personal injury and property damage.
30.93 8614 Rev D Updated 09/2019 © 2019 Victaulic Company. All rights reserved.
victaulic.com 8