You are on page 1of 4

EST Catalog u Strobes, Horns, Bells, Chimes

Synchronized
Strobe
202-7A, 202-8A, 203-8A MEA
Patented

Overview Standard Features


202 Series strobes are specially designed for use with compatible • UL 1971-listed synchronizing strobe
life safety communication and control equipment to alert the hear- Integrity strobes synchronize to the latest UL 1971 require-
ing impaired of a life safety event. Strobes are available with 15/75 ments when used with a synchronization source.
cd, and 110 cd effective flash intensity. They are fully compatible
• Genesis-compatible
with Genesis signals.
All Genesis and Integrity strobes on the same circuit meet UL
Strobes are shipped with standard wall mount style “FIRE” lens 1971 synchronization requirements when used with an external
markings. Where ceiling mount, other languages, or different lens control module.
markings are required, Edwards offers optional LKW and LKC • Approved for public and private mode applications
series Lens Marking Kits. These optional lens markings simply UL 1971-listed as signaling devices for the hearing impaired
snap on to the strobe. Consult Edwards for availability of special and UL 1638-listed as protective visual signaling appliances.
lens markings.
• Rated for wall or ceiling installation
202 Series strobes are designed for 16 to 33 Vdc operation and
must be connected to signal circuits that output a constant (not • Field changeable field markings
pulsed) voltage. A diode is used to allow full signal circuit supervi- Lens language or standard “FIRE” marking is easily changed
sion and polarized connections are made to terminals that accept with optional LKW and LKC series lens kits.
up to #12 AWG (2.5mm²) wire. The 203 Series strobe operates • Screw terminal wire connection
from a 120 Vac 50/60 Hz supply and is not synchronized. Large terminals speed installation and accept up to #12 AWG
The strobe housing/front plate is finished in red or white and is (2.5mm²) wire.
made from durable and fire retardant, high impact plastic with a • Fits one-gang flush box
slightly textured surface. Ideal for retrofit and renovation projects. Optional color-
matched surface boxes available.

Page 1 of 4 D ATA S H E E T 85001-0369


Not to be used for installation purposes. Issue 11
Application
NOTE: The installation of visible and audible signals are subject to national and local standards, codes, and ordinances.
Consult your Authority Having Jurisdiction for device installation requirements, application standards, and minimum performance specifications.

Edwards strobes are UL 1971-listed for use indoors as wall-mounted Integrity strobes are fully compatible with Edwards Genesis sig-
public-mode notification appliances for the hearing impaired. Prevail- nals.
ing codes require strobes to be used where ambient noise conditions
exceed specified levels, where occupants use hearing protection,
and in areas of public accommodation. Consult with your Authority NOTE: The flash intensity of some visible signals may not be adequate
Having Jurisdiction for details. to alert or waken occupants in the protected area. Research indicates
that the intensity of strobe needed to awaken 90% of sleeping persons
As part of the Enhanced Integrity line of products, 202/203 Series
is approximately 100 cd. Edwards recommends that strobes in sleeping
strobes exceed UL synchronization requirements (within 10 mil- rooms be rated at at least 110 cd.
liseconds other over a two-hour period) when used with a syn-
chronization source. Synchronization is important in order to avoid WARNING: These devices will not operate without electrical power. As
epileptic sensitivity. fires frequently cause power interruptions, further safeguards such as
backup power supplies may be required.

Installation and Mounting Light Distribution Patterns


All models fit to a standard flush mounted, North American one- UL 1971 WALL MOUNTED STROBE LIGHT OUTPUT
gang electrical box, two inch (51mm) deep minimum. Optional
Strobes Edwards
15/75color-matched
cd (-7A) Series indoor surface-mount
Strobes 30 boxes
15 cd (-3A)
(-5A) are avail-
Series Strobes 15/75
75 cdcd(-4A)
(-7A)Series
SeriesStrobes
Strobes 110
30 cd
cd (-3A)
(-8A) Series
Series Strobes
Strobes 75 cd (-4A
ut able. Strobes must be connected
Horizontal Output to signal circuits which
Horizontal
Horizontal Output output a
Output Horizontal
Horizontal Output
Output Horizontal
Horizontal Output
Output Hori
constant (not pulsed) voltage. Edwards recommends that these
ddeeggrreeeess ddeeggrreeeess ddeeggrreeeess
degrees
strobes always be installed
0 in accordance with the latest 0
0 recog- 0 -15 00
-15 15 -15
-15 15
15 -15 15 -15 15
15 30 -1
30 nized edition
-30of national and30 local fire alarm codes.
-30
-30 30
30 -30 30 -30
-30 30 -30
45 -45 45 -45
-45 45
45 -45 45 -45
-45 45
45 -45
60 -60 60 -60
-60 60
60 -60 60 -60
-60 60
60 -60
75 -75 FRONT VIEW 75 SIDE
-75 VIEW
-75 75
75 -75 75 -75
-75 75
75 -75
1.09” 90
90 -90 90 -90
-90 0.25” 90
90 -90 90 -90
-90 90 -90
(28 mm)
20 30 100 50 cd 50 100 30(6 mm)
60 20 20
40 cd 20
10 cd 20 60
10 40 30 140 60 cd 60 50
10010050 100 140
100 200
60 4010020 cd 10040 200
cd 20 60 140 100 6
t Vertical Output Vertical
Vertical Output
Output Vertical
Vertical Output
Output Vertical
Vertical Output
Output Ver
-90-75 -90
-90-75
-75 -90
-90-75 -90
-90-75 -90
100 -60 30
60 -60
-60 100 -75
140 -60
-60 150
60
-75
-60
-60 140
5” -45 -45
-45 -45
-45 -45
-45
(127 mm) 20
0 -30 5”40 -30
-30 100 -30
-30 40
100 -30
-30 100
50 (127 mm) 50
15 -15 10
20 -15
-15 60 -15
-15 20 -15
-15 60
50
degrees

degrees

degrees

degrees

de
d eg
grre
0 cd 0 cd 00 cd
cd 00 cd
cd 00 cd

eeess
5 15 10
20 15
15 60 15
15 50
20 15
15 60
50 3.4” 30 30
30 50 30
30 30
30
(86 mm) 20 1.9” 100 100 100
45 40 (4845
45
mm) 45
45 40 45
45
“FIRE” lens100 60
(wall orientation) 60
60 table). 60
60 60
60
90 75 supplied. Other lens markings are available
30 (see75
60
90
90
ordering
75 140
100 90
90 75
75 150
60 90
90 75
75 140
90
min Average UL min Average
Average UL
UL min
min Average
Average UL
UL min
min Average
Average UL
UL min
min Avera

MOUNTING PLATE
Vertical
-90°
Vertical
-90°
-90°

-90°
90°
Horizontal
90°
Horizontal
90°
90°

Two pan head slotted screws are provided to


secure mounting plate to 1-gang electrical box.

Page 2 of 4 D ATA S H E E T 85001-0369


Not to be used for installation purposes. Issue 11
Typical Wiring — 24 Vdc
(+)
CAUTION: This unit is designed to be used on signal circuits that output a constant
UL/ULC Listed Place an end-of-
voltage. Do not connect this unit to a coded or pulsating voltage. Electrical supervi-
24V dc line resistor on the sion requires wire run to be broken at each device. Do not loop signal circuit field
Fire Alarm last device (resistor wires around the strobe terminals.
Control Panel supplied with
(signal circuit) S Strobe S Strobe
control panel)

(-)

Operating Current (RMS)


UL Rating 15/75 cd 110 cd Current Draw Notes and Comments
16 Vdc 150 329 1. Current values are shown in mA.
16 Vfwr 210 420 2. UL Nameplate Rating can vary from Typical Current due to measurement meth-
ods and instruments used.
3. Edwards recommends using the Typical Current for system design including
Typical Current 15/75 cd 110 cd NAC and Power Supply loading and voltage drop calculations.
24 Vdc 90 180 4. Use the 16 Vdc RMS current ratings for filtered power supply and battery AH
24 Vfwr 128 260 calculations. Use the 16 Vfwr RMS current ratings for unfiltered power supply
calculations.
Vdc: Volts direct current, regulated and filtered 5. Fuses, circuit breakers and other overcurrent protection devices are typically
Vfwr: Volts full wave rectified rated for current in RMS values. Most of these devices operate based upon
the heating affect of the current flowing through the device. The RMS current
determines the heating affect and therefore, the trip and hold threshold for those
devices.

Specifications
Catalog Number 202-7A 202-8A 203-8A
UL 1971 Rated Strobe Output - 15cd 110cd
110cd (wall); 60cd (ceiling)
candela (cd) (wall or ceiling) (wall); 60cd (ceiling)
UL 1638/ULC S526 Rated Strobe
75cd 110cd 110cd
Output
Synchronized at one flash per second. External control module necessary
Non-synchronized
Strobe Flash Rate to meet UL 1971 synchronization requirements of 10 milliseconds over a
at one fps.
two-hour period.
Strobe Operating Volts 16-33 Vdc/fwr (UL voltage designations “Regulated 24” and “24 fwr”) 120 Vac 50/60Hz
Synchronization Sources G1M-RM, SIGA-CC1S, SIGA-MCC1S, BPS6A, BPS10A
Environment for 93% relative humidity @ 86º F (30º C);
Indoor Rating Temperature Range 32º F to 120º F (0º C to 49º C)
95% relative humidity @ 90º F (32º C);
Environment for Outdoor Rating
Temperature Range -40º F to +150º F (-40º C to +66º C)
Supplied with LKW-1 “FIRE” red letters, vertical both sides (Wall Mount).
Lens Markings
See LKW and LKC series for ceiling style and optional markings.
Wire Connections Terminals - polarized input, #12 AWG (2.5mm²) max wire size
Flash Tube Enclosure Clear LEXAN
Strobe Plate, Finish Textured color-impregnated plastic. Exceeds 94V-0 UL Flammability Rating
Flush - One-gang, 2-inch deep North American electrical box;
Mounting
Surface - 27193 series box or one-gang wiremold box.
UL 1971, UL 1638, ULC S526, CE, FM, CSFM, MEA (All models comply with ADA Code of Federal Regulation
Agency Listings
Chapter 28 Part 36 Final Rule)

Page 3 of 4 D ATA S H E E T 85001-0369


Not to be used for installation purposes. Issue 11
Ordering Information
Ship Wt.
Catalog Number Description
lb. (kg)
202-7A-T Strobe - 15/75 cd, Red
202-7A-TW Strobe - 15/75 cd, White
Detection & alarm since 1872
202-8A-T Strobe - 110 cd, Red
1 (0.45)
U.S. 202-8A-TW Strobe - 110 cd, White
T 888-378-2329 203-8A-T Strobe - 110 cd, 120 Vac, Red
F 866-503-3996 203-8A-TW Strobe - 110 cd, 120 Vac, White
Canada Synchronization Sources
Chubb Edwards G1M-RM Genesis Signal Master Remote Mount (1-gang) 0.2 (0.1)
T 519 376 2430 Synchronization Output Module (Standard Mount) - UL/
F 519 376 7258 SIGA-CC1S 0.5 (0.23)
ULC Listed
Southeast Asia SIGA-MCC1S Synchronization Output Module (UIO Mount) - UL Listed 0.18 (0.08)
T : +65 6391 9300 BPS6A 6.5 Amp Booster Power Supply 13 ( 5.9)
F : +65 6391 9306 BPS10A 10 Amp Booster Power Supply 13 ( 5.9)
Mounting Accessories
India
T : +91 80 4344 2000 Surface Mount Box
27193-11
F : +91 80 4344 2050 - Indoor, 1-gang Red
1 (0.45)
  Surface Mount Box
Australia 27193-16
-Indoor, 1-gang White
T +61 3 9239 1200
F +61 3 9239 1299
Lens Markings Kits
LKW-1 “FIRE” - Wall (supplied)
Europe LKW-1R “FIRE” - Wall (Red)
T +32 2 725 11 20 LKW-2 “FEU” - Wall
F +32 2 721 86 13 LKW-3 “FIRE/FEU” - Wall
LKW-4 “SMOKE” - Wall
Latin America
LKW-5 “HALON” - Wall
T 305 593 4301
F 305 593 4300 LKW-6 “CO2” - Wall
LKW-7 “EMERGENCY” - Wall
utcfireandsecurity.com LKW-8 “ALARM” - Wall
LKW-9 “FUEGO” - Wall (0.2 lb, 0.1 kg)
© 2010 UTC Fire & Security. LKC-1 “FIRE” - Ceiling
All rights reserved.
LKC-2 “FEU” - Ceiling
LKC-3 “FIRE/FEU” - Ceiling
LKC-4 “SMOKE” - Ceiling
LKC-5 “HALON” - Ceiling
LKC-6 “CO2” - Ceiling
LKC-7 “EMERGENCY” - Ceiling
LKC-8 “ALARM” - Ceiling
LKC-9 “FUEGO” - Ceiling

05-18-11

Page 4 of 4 D ATA S H E E T 85001-0369


Not to be used for installation purposes. Issue 11

You might also like