You are on page 1of 116

INTRODUCTION

Grant Prideco’s TCA™ product line provides seamless for the complete Grant Prideco product lines are
oil country tubular goods (OCTG), line pipe and available and easily printed, e-mailed or downloaded.
associated services. Specializing in the production Resources like interactive equations from API 5C3
of high performance, proprietary, and custom casing, are available in the Equation Bank™ section of the
TCA also produces API 5CT and 5L products at its tool kit. A unit conversion application makes it very
manufacturing facility in Muskogee, Oklahoma. convenient to determine conversion units to help the
Additionally, Grant Prideco provides engineering technical community in their everyday work. Other
and technical services to assist you in selecting components are being added on an ongoing basis to
the optimum casing solution for any downhole further help those in the OCTG community as Grant
application, especially critical applications. Prideco strives to remain a leader in the production
of high performance tubular products.
Over the last several years Grant Prideco’s TCA Facility
has been instrumental in providing the industry with Our Products
high performance tubulars. When quick delivery is TCA produces casing from 5 inch through 16-1/8 inch
imperative and there is a need for technical resources outside diameter and up to 150 pounds per foot.
to aide the engineering and OCTG community –
Grant Prideco has been at the forefront. The Premium In addition to standard API 5CT casing grades, TCA’s
PipePak™ and The Engineering Tool Kit™ are the proprietary high-performance casing products include:
primary examples of this effort. • Enhanced Burst – a controlled yield strength
product with a burst rating up to 13.6% greater
The Premium PipePak™ than similar API grades.
The Premium PipePak™ is a unique package of • High Collapse – provides collapse resistance
premium pipe with an Atlas Bradford™ premium greater than API grades and is typically verified with
connection which is inspected in accordance with a length to diameter ratio of 8:1 physical testing.
End User requirements to facilitate quick delivery • eXtreme™ – an enhanced burst and high
directly to the rig site. This tubular goods package collapse product (previously referred to as EHC).
provides considerable cost savings and single source • Sour Service – NACE tested high-strength
reliability and responsibility to the Purchaser. grades for H2S service.
• High Strength – ultra-high yield strength
The Engineering Tool Kit™
products.
The Engineering Tool Kit™ is a new web based
• Geothermal – for service in high-temperature,
initiative to provide technical resources to the OCTG
corrosive environments.
community. By directing your web browser to the
• Riser – enhanced toughness for fatigue resistance
Engineering Tool Kit™ at the Grant Prideco Web Site
plus weldability.
(http://www.grantprideco.com) a wealth of informa-
tion becomes available. All specifications and perfor-
mance properties (Specs Direct™ and Pipe Builder™)

1
TCA CASING

2
While every effort has been made to ensure the accuracy of the data in these tables, this material is presented as a reference guide only. The technical information contained in these pages
should not be construed as a recommendation. Grant Prideco cannot assume responsibility for the results obtained through the use of this material. No expressed or implied warranty is intended.
CASING

Grant Prideco will also produce pipe to meet • Since the yield strength is within the limits of API
your specific requirements, including: 5CT, the enhanced burst grades may be used in
• Non-standard sizes and weights sour service applications as recommended by
• Custom grades NACE Standard MRO175.
• Special inspections
• Special testing
• Special documentation

Enhanced Burst Casing


• Compared to standard grades, enhanced burst
products often allow you to reduce pipe weight
and cost.
• P-110 E provides the same internal yield strength
(“burst”) rating as Q-125 at lower cost.
• Enhanced burst grades meet all minimum
API 5CT requirements and are monogrammed
(depending on size and weight).
Controlled yield strength provides enhanced performance
• Utilizing modern metallurgical practices and process
and allows reduction of pipe weight and cost.
controls, the yield strength of enhanced burst products
is limited to the high end of the API range.

High Collapse Casing • High collapse performance is verified by


• Compared to standard API 5CT grades, high collapse testing. Test samples typically have
collapse products often allow you to reduce a length to diameter ratio of approximately 8:1.
pipe weight and increase setting depth. • High collapse grades meet all minimum API 5CT
• Precise control of yield strength and wall requirements and are monogrammed (depending
thickness, combined with manufacturing on size and weight).
practices that result in minimum residual
stress and a high proportional limit increases
collapse resistance.
• Collapse ratings are predicted with the
TCA modified Tamano 4 equation and
verified by physical testing.

Increased Setting Depth in 14 ppg Mud With High


Collapse capability is verified by testing with Collapse Casing
approximately 8:1 length to diameter test samples.
3
TCA CASING

Sour Service Casing • NACE TM0177 Method D sulfide stress corrosion


• Grant Prideco is a leading producer of casing resistance testing can be provided.
for sour service applications. • C-90, C-90 HC, T-95, T-95 E, T-95 eXtreme™
• Our high-strength NACE tested products provide C-110, and C-110 HC casing grades comply with
workable solutions for the design of deep, the requirements of NACE Standard MRO175.
high-pressure, sour wells.
• Special chemistry and superior OD/ID quench-and-
temper processing ensure through wall uniformity
and complete martensitic transformation.
• Superior sulfide stress cracking resistance is
obtained by controlling hardness, strength,
microstructure and utilizing practices that promote
steel cleanliness and minimize residual stress.
• Standard sulfide stress corrosion resistance testing
is conducted at a frequency of one sample per
heat in conformance with NACE TM0177 Method A
requirements at a minimum threshold stress level
of 80% of the specified minimum yield strength
(SMYS).
NACE Method A test cell

4
CASING

eXtreme™ and eXtreme Plus™ Casing • T-95 eXtreme™ casing complies with the
• eXtreme™ casing products offer the ultimate in requirements of NACE Standard MRO175.
tubular performance. • In addition, eXtreme Plus™ products provide at
• eXtreme™ casing products provide enabling least one-third of an order with 90% minimum
tubular technology that affords design options for remaining body wall.
difficult wells.
• eXtreme™ casing products have the burst
resistance of our Enhanced Burst products with
the increased collapse resistance of our
High Collapse products.
• All eXtreme™ casing products exceed
all minimum API 5CT
requirements and
are monogrammed
(depending on size and weight).

The pipe body VME curve at right illustrates the increased


performance that is available from Grant Prideco’s
Enhanced Burst, High Collapse, and eXtreme casing products.

Ultra-High Strength Casing Geothermal Casing


• When ultra-high strength is required for a well’s • Grant Prideco’s geothermal casing products
tubular design, Grant Prideco can provide ultra-high provide the high-temperature strength required
strength TCA-140 and TCA-150. for geothermal applications.
• These products utilize rich chemistry and controlled • In addition, TCA-80 GSS, TCA-90 GSS, and
processing to achieve the desired high tensile TCA-95 GSS comply with the requirements of
strength and maintain superior fracture toughness. NACE Standard MRO175.
• TCA-140 and TCA-150 provide an economical • Standard sulfide stress corrosion resistance testing
solution for deep, high-pressure applications. is conducted at a frequency of one sample per
heat in conformance with NACE TM0177
Riser Casing Method A requirements at a minimum threshold
• Grant Prideco’s riser casing products provide the stress level of 80% of the specified minimum
high-fatigue resistance and weldability required for yield strength (SMYS).
deepwater riser applications.
• A specialized chemistry, modern metallurgical
processing and precise process controls are utilized
to produce a product with increased fracture
toughness and fatigue resistance.
• Lower carbon levels allow the welding of flanged
connectors, vortex strakes, and other riser
appurtenances.
5
T C A PREMIUM PIPEPAK™ [PPP]

The Premium Pipe Pak™ • Only Prime Footage is Shipped –


In 1999 TCA began offering the industry the ability No Additional Pipe Must Be Ordered by
to purchase pipe from one source that is truly “rig Distributor or Operator to Compensate for
ready.” The installation of a premium Atlas Bradford Threading Re-works or Inspection Rejects
threading line, in conjunction with Third Party • Combined Technical Support for TCA and
inspection in Muskogee, facilitates shipping finished Atlas Bradford
pipe direct to the rig site without the traditional
intermediate shipments for inspection, threading The PPP provides the End User with considerable
and additional handling. The benefits of the Premium cost savings when you consider:
PipePak™ (PPP) are numerous: • Administrative Time for Ordering is Reduced
• Quick Delivery of “Rig Ready” Product • Shipping Costs are Reduced
• “One Stop Shop” for your Casing Needs • Only Prime Finished Pipe Needs to be Ordered
• World Renowned Atlas Bradford Premium • Reduced Handling Damage Due to Reduced
Connections Handling
• One Manufacturer Responsible for the Entire Product • Reduced Risk of Non-conforming Pipe Arriving
• Capability for Incorporating End User Inspection at Rig Site
Requirements Into the Standard Mill Inspection • Reduced Time to Provide Technical Support to
• The Confidence of Independent Third Party TCA Customers
Inspection • Less Risk for Mechanical Damage of Sour Service
• The Latest in Modern NDT Inspection Equipment Products (SSP) Which Translates to Less Chance
• Ability to Order Matching Casing Accessories of Mechanical Damage Related Failures.
from Tube-Alloy
• The Benefits of Minimal Handling on
Sour Service Products

6
PREMIUM PIPEPAK™ [PPP]

TYPICAL FLOW CHART: PREMIUM PIPEPAK™ FROM TCA / AB / THIRD PARTY


Premium PipePak orders are typically built for a specific operator order

TYPICAL FLOW CHART: CASING WITH PREMIUM CONNECTIONS


Flow Chart is for orders placed by USA Distributors for their inventory

7
T C A THE ENGINEERING TOOL KIT™

Grant Prideco has initiated a unique interactive web


site to provide the OCTG community and the design The Engineering Tool Kit
engineer with considerable resources to aid in their currently has five components:
day-to-day activities. There are numerous instances
• Pipe Builder™
where information on tubular products is needed to
further understand the attributes of tubulars and • Specs Direct™
obtain clear concise performance properties and pipe • The Equation Bank™
options for design considerations. Grant Prideco has • Converter
compiled several resources which are available online • Glossary of Terms
(www.grantprideco.com) for industry use. The site is
"ever changing" with our eye toward continuous
improvement and functionality.

Pipe Builder™
Pipe Builder™ allows the engineer to
input design requirements such as
collapse and burst resistance to obtain
valid pipe options for a specific casing
application. Pipe Builder™ provides the
User with a "Best Pipe" or "All Pipes" Step 1
solution. Upon obtaining the solution
best suited for the engineer’s applica-
tion, the specifications for the pipe
body, API connection or Atlas Bradford
premium connections can be viewed
and printed for future reference.

Example:
Drilling Engineer is planning on setting
9 5/8" x 53.50 lb/ft casing to a depth of Step 2
12,000 feet in a sweet well and must be
able to withstand 12,000 PSI internal
pressure and a collapse pressure of
10,000 PSI. Using Pipe Builder™ the User
can assess which pipe grade best suits his
criteria or can review several pipe options.
Upon finding various pipe options the
User can select an API or Atlas Bradford
connection and obtain performance Step 3
properties. The engineer then can request
that pipe options be presented if the well
turns out to be sour.

8
THE ENGINEERING TOOL KIT™

Specs Direct™
Specs Direct™ permits the User to select
any API pipe grade or proprietary high
performance grades like those offered by
TCA and print out data sheets depicting
the product performance properties
and dimensions. For Atlas Bradford end
finishes, data on blanking dimensions
can also be obtained. This tool can be
used just like a catalog but in addition
gives the User the added flexibility of
printing out the query for documentation
for future reference.

The Equation Bank™


The Equation Bank™ is a key resource
for engineers that enables them to
perform calculations related to pipe
performance. This interactive web
application, using Web Mathmatica, is
a powerful tool that enables the User to
perform calculations related to tubular
goods. The application permits the
User to enter all but one variable of the
equation and the missing variable is
calculated. The vast majority of the
equations detailed in API 5C3 - 6th
Edition – Bulletin on Formulas and
Calculations for Casing, Tubing, Drill
Pipe and Line Pipe Properties are
available for interactive use.

Converter
Converter is an interactive application that
facilitates unit conversions. Units of force,
length, area, flow, pressure, density, volume,
torque and others are easily converted from
either english or metric units.

Glossary of Terms
Hundreds of terms and their definitions are
available to improve ones understanding of pipe
related manufacturing and operational issues.

9
TCA PRODUCTION PROCESS

Our Process
From design through finishing, Grant Prideco incorporates
the best tubular manufacturing technology to ensure a
metallurgically superior product.

Continuous cast steel making


and modern ladle metallurgy
are utilized in the production
of Grant Prideco’s casing.

Green Tubes
• Green tubes are manufactured to our proprietary
specifications, including enhanced chemistries,
assuring compatibility with our Q&T process.
• Select mills produce billets for pipe making using
the latest ladle metallurgy and continuous cast
steel making procedures.
• Billets are typically rotary pierced, producing
green tubes with greater dimensional control.

Austenitizing and Tempering


• Modern computer controlled, walking-beam
furnaces assure that advanced metallurgical
properties are achieved.
• The gas-fired, multi-zoned process results in
homogenous heating and precise soaking of
the tubulars.

10
PRODUCTION PROCESS

Quenching
• The unique simultaneous OD/ID quench process ensures complete
through wall martensitic transformation and results in superior
metallurgical properties and optimum “as quenched” straightness.
• The computer-monitored quench process features a high pressure
descaler and 12,000 gallon per minute quenching capacity.
• Enables processing of heavy wall casing and coupling stock.
• Certain products may be OD quenched only.
Uniform through wall hardness

Through wall martensitic transformation

Hot Sizing and Straightening


• Sizing and straightening of high performance
products are accomplished at elevated
temperatures, resulting in improved metallurgical
properties and consistent dimensional control.
• Hot working near the tempering temperature
prevents degradation of the proportional limit
and optimizes the pipe’s performance properties.

Tensile test plot (above) of Grant Prideco’s casing approaches


the ideal stress-strain curve with a “sharp knee” transition from
the elastic to plastic region.

11
TCA PRODUCTION PROCESS

EMI Inspection
• The state-of-the-art electromagnetic pipe imaging
inspection unit provides more precise flaw detection
than traditional EMI, detects imperfections at multiple
angles, and differentiates multiple flaws on the
same circumference.
• Minimum wall thickness is assured by 100%
UT coverage.
• Inspection certification is provided for each order
with mill test report.
• A Level 3 technician supervises certified Level 2
operators and prove-up technicians.

UT Inspection
• An independent third-party inspection eliminates the
need for the operator to make redundant inspections.
• Full length ultrasonic inspection has a high pulse
repetition rate and capability to detect longitudinal,
transverse, and selected oblique flaws.
• The computer-controlled data acquisition system
provides data storage and retrieval.
• Inspection certification is provided for each order
with mill test report.
• An ASNT Level 3 technician certifies Level 2 operators
and prove-up technicians.

12
PRODUCTION PROCESS

End-Area Inspection API Threading


• End-area inspections are conducted on • Finishing with API connections is accomplished
plain-end pipe and after threading as required. on double-ended threading lines with CNC
• Inspections are conducted by certified machine tools.
Level 2 technicians. • Sizes from 5 inch to 13-5/8 inch can be threaded
with API STC, LTC and buttress connections.
Finishing Line
• Pipe is drifted, hydro-tested, weighed, measured,
stenciled and protective mill lacquer coating is
applied on the finishing line.

Atlas Bradford®
Premium Threading Center
• A new $4 million premium threading center was
completed in 1999.
• The double-ended 14 inch threading line
features Mori Seiki SL-80C CNC machine tools
with Fanuc controllers.
• Size range: 5 inch to 13-5/8 inch.
• Pipe preparation for integral joint connections is
accomplish by cold-forming the ends on either
the 500-ton horizontal swage unit or the
500-ton vertical swage unit as required. Swaging
is followed by thermal stress relieving with the
100 KW 10 KHz, dual coil induction unit.
• Abrasive blast surface finish, wet magnetic
particle SEA inspection, and computer-controlled
coupling buck-on can be included in an efficient
assembly line process to furnish a completed
product.

Atlas Bradford® products are produced in a new


state-of-the-art premium threading center.
13
TCA QUALITY

Our Quality
Grant Prideco is an authorized API producer
of oil country tubular goods and line pipe
and is licensed under API Specifications 5CT
and 5L. Our documented quality program
complies with both API Q1 and ISO 9001.

14
SERVICE

Our Delivery • Common sizes of green tube and coupling stock


• Deliveries average weeks instead of months. inventory for sour service products are NACE
• To expedite orders, Grant Prideco maintains an tested upon receipt to further reduce delivery time.
extensive inventory of green tubes at the TCA • This reduced lead time provides user flexibility and
facility in Muskogee, Oklahoma. helps prevent costly rig down time.
• Green tubes are custom-processed to meet your • In situations where critical delivery cannot otherwise
grade and inspection requirements. be met, Grant Prideco can reprocess an operator’s or
• We also maintain inventories of green coupling distributor’s existing inventory to the required grade.
stock and of finished Atlas Bradford® TC-II™ Evaluation by our technical staff can determine in
couplings. advance the acceptability of existing inventory to
produce the desired grade.

Our Custom Products and Services Our Technical Services


Grant Prideco will produce custom casing designed to The Grant Prideco technical marketing staff is results-
meet your specific grade, size, weight, and/or tailored oriented and offers you the following support services:
inspection and testing requirements. This process • Customized performance property tables comparing
begins with a thorough review and evaluation of your a variety of standard and proprietary grades and
requirements by our technical staff. We work directly connections.
with you to develop a product specification and • Tailored technical seminars designed to provide
quality plan that meets your specific requirements. an understanding of casing products, performance
and applications.
• Assistance in evaluating field applications,
performance problems, and running procedures.
• Significant cost savings by providing the best
solution for your application.

15
T C A PIPE DATA INTRODUCTION

Pipe Data Legend:


1 Plain End Collapse Resistance Minimum = 5 Round Thread Internal Yield Pressure Minimum =
Minimum collapse resistance of the pipe body Minimum burst resistance of the API 8 round thread
based on equations in API Bulletin 5C3 based on equations in API Bulletin 5C3
2 Plain End Body Yield Strength = Minimum burst 6 Buttress Thread Joint Strength = The axial load
resistance of the pipe body based on equations in limit of an API Buttress thread based on equations in
API Bulletin 5C3 API Bulletin 5C3
3 Plain End Internal Yield Pressure Minimum 7 Buttress Thread Internal Yield Pressure Minimum
4 Round Thread Joint Strength = The axial load 8 Atlas Bradford Joint Strength = The axial load
limit of an API 8 Round thread based on equations limit based on the critical cross sectional area times
in API Bulletin 5C3 the yield strength of the pipe body

The internal leak resistance of a threaded and coupled internal leak resistance of an API threaded and coupled
API product is the lowest of the internal yield pressure product is reduced due to the couplings inability to
of the pipe (Equations #31 and #32 in API Bulletin hold the same pressure as the pipe which results from
5C3 — Bulletin on Formulas and Calculations for insufficient coupling strength. The table above shows
Casing, Tubing, Drill Pipe and Line Pipe Properties: the maximum leak resistance ratings for API standard
Sixth Edition) or the coupling. In many cases the products.

16
5" PIPE DATA

17
While every effort has been made to ensure the accuracy of the data in these tables, this material is presented as a reference guide only. The technical information contained in these pages
should not be construed as a recommendation. Grant Prideco cannot assume responsibility for the results obtained through the use of this material. No expressed or implied warranty is intended.
T C A PIPE DATA 5"

18
While every effort has been made to ensure the accuracy of the data in these tables, this material is presented as a reference guide only. The technical information contained in these pages
should not be construed as a recommendation. Grant Prideco cannot assume responsibility for the results obtained through the use of this material. No expressed or implied warranty is intended.
5" c o n t i n u e d PIPE DATA

19
While every effort has been made to ensure the accuracy of the data in these tables, this material is presented as a reference guide only. The technical information contained in these pages
should not be construed as a recommendation. Grant Prideco cannot assume responsibility for the results obtained through the use of this material. No expressed or implied warranty is intended.
T C A PIPE DATA continued 5"

20
While every effort has been made to ensure the accuracy of the data in these tables, this material is presented as a reference guide only. The technical information contained in these pages
should not be construed as a recommendation. Grant Prideco cannot assume responsibility for the results obtained through the use of this material. No expressed or implied warranty is intended.
5" c o n t i n u e d PIPE DATA

21
While every effort has been made to ensure the accuracy of the data in these tables, this material is presented as a reference guide only. The technical information contained in these pages
should not be construed as a recommendation. Grant Prideco cannot assume responsibility for the results obtained through the use of this material. No expressed or implied warranty is intended.
T C A PIPE DATA continued 5"

22
While every effort has been made to ensure the accuracy of the data in these tables, this material is presented as a reference guide only. The technical information contained in these pages
should not be construed as a recommendation. Grant Prideco cannot assume responsibility for the results obtained through the use of this material. No expressed or implied warranty is intended.
5" c o n t i n u e d PIPE DATA

23
While every effort has been made to ensure the accuracy of the data in these tables, this material is presented as a reference guide only. The technical information contained in these pages
should not be construed as a recommendation. Grant Prideco cannot assume responsibility for the results obtained through the use of this material. No expressed or implied warranty is intended.
T C A PIPE DATA continued 5"

24
While every effort has been made to ensure the accuracy of the data in these tables, this material is presented as a reference guide only. The technical information contained in these pages
should not be construed as a recommendation. Grant Prideco cannot assume responsibility for the results obtained through the use of this material. No expressed or implied warranty is intended.
5-1/2" PIPE DATA

25
While every effort has been made to ensure the accuracy of the data in these tables, this material is presented as a reference guide only. The technical information contained in these pages
should not be construed as a recommendation. Grant Prideco cannot assume responsibility for the results obtained through the use of this material. No expressed or implied warranty is intended.
T C A PIPE DATA continued 5-1/2"

26
While every effort has been made to ensure the accuracy of the data in these tables, this material is presented as a reference guide only. The technical information contained in these pages
should not be construed as a recommendation. Grant Prideco cannot assume responsibility for the results obtained through the use of this material. No expressed or implied warranty is intended.
5 - 1 / 2 " continued PIPE DATA

27
While every effort has been made to ensure the accuracy of the data in these tables, this material is presented as a reference guide only. The technical information contained in these pages
should not be construed as a recommendation. Grant Prideco cannot assume responsibility for the results obtained through the use of this material. No expressed or implied warranty is intended.
T C A PIPE DATA continued 5-1/2"

28
While every effort has been made to ensure the accuracy of the data in these tables, this material is presented as a reference guide only. The technical information contained in these pages
should not be construed as a recommendation. Grant Prideco cannot assume responsibility for the results obtained through the use of this material. No expressed or implied warranty is intended.
5 - 1 / 2 " continued PIPE DATA

29
While every effort has been made to ensure the accuracy of the data in these tables, this material is presented as a reference guide only. The technical information contained in these pages
should not be construed as a recommendation. Grant Prideco cannot assume responsibility for the results obtained through the use of this material. No expressed or implied warranty is intended.
T C A PIPE DATA continued 5-1/2"

30
While every effort has been made to ensure the accuracy of the data in these tables, this material is presented as a reference guide only. The technical information contained in these pages
should not be construed as a recommendation. Grant Prideco cannot assume responsibility for the results obtained through the use of this material. No expressed or implied warranty is intended.
5 - 1 / 2 " continued PIPE DATA

31
While every effort has been made to ensure the accuracy of the data in these tables, this material is presented as a reference guide only. The technical information contained in these pages
should not be construed as a recommendation. Grant Prideco cannot assume responsibility for the results obtained through the use of this material. No expressed or implied warranty is intended.
T C A PIPE DATA continued 5-1/2"

32
While every effort has been made to ensure the accuracy of the data in these tables, this material is presented as a reference guide only. The technical information contained in these pages
should not be construed as a recommendation. Grant Prideco cannot assume responsibility for the results obtained through the use of this material. No expressed or implied warranty is intended.
6-5/8" PIPE DATA

33
While every effort has been made to ensure the accuracy of the data in these tables, this material is presented as a reference guide only. The technical information contained in these pages
should not be construed as a recommendation. Grant Prideco cannot assume responsibility for the results obtained through the use of this material. No expressed or implied warranty is intended.
T C A PIPE DATA continued 6-5/8"

34
While every effort has been made to ensure the accuracy of the data in these tables, this material is presented as a reference guide only. The technical information contained in these pages
should not be construed as a recommendation. Grant Prideco cannot assume responsibility for the results obtained through the use of this material. No expressed or implied warranty is intended.
6 - 5 / 8 " continued PIPE DATA

35
While every effort has been made to ensure the accuracy of the data in these tables, this material is presented as a reference guide only. The technical information contained in these pages
should not be construed as a recommendation. Grant Prideco cannot assume responsibility for the results obtained through the use of this material. No expressed or implied warranty is intended.
T C A PIPE DATA continued 6-5/8"

36
While every effort has been made to ensure the accuracy of the data in these tables, this material is presented as a reference guide only. The technical information contained in these pages
should not be construed as a recommendation. Grant Prideco cannot assume responsibility for the results obtained through the use of this material. No expressed or implied warranty is intended.
6 - 5 / 8 " continued PIPE DATA

37
While every effort has been made to ensure the accuracy of the data in these tables, this material is presented as a reference guide only. The technical information contained in these pages
should not be construed as a recommendation. Grant Prideco cannot assume responsibility for the results obtained through the use of this material. No expressed or implied warranty is intended.
T C A PIPE DATA continued 6-5/8"

38
While every effort has been made to ensure the accuracy of the data in these tables, this material is presented as a reference guide only. The technical information contained in these pages
should not be construed as a recommendation. Grant Prideco cannot assume responsibility for the results obtained through the use of this material. No expressed or implied warranty is intended.
6 - 5 / 8 " continued PIPE DATA

39
While every effort has been made to ensure the accuracy of the data in these tables, this material is presented as a reference guide only. The technical information contained in these pages
should not be construed as a recommendation. Grant Prideco cannot assume responsibility for the results obtained through the use of this material. No expressed or implied warranty is intended.
T C A PIPE DATA continued 6-5/8"

40
While every effort has been made to ensure the accuracy of the data in these tables, this material is presented as a reference guide only. The technical information contained in these pages
should not be construed as a recommendation. Grant Prideco cannot assume responsibility for the results obtained through the use of this material. No expressed or implied warranty is intended.
7" PIPE DATA

41
While every effort has been made to ensure the accuracy of the data in these tables, this material is presented as a reference guide only. The technical information contained in these pages
should not be construed as a recommendation. Grant Prideco cannot assume responsibility for the results obtained through the use of this material. No expressed or implied warranty is intended.
T C A PIPE DATA continued 7"

42
While every effort has been made to ensure the accuracy of the data in these tables, this material is presented as a reference guide only. The technical information contained in these pages
should not be construed as a recommendation. Grant Prideco cannot assume responsibility for the results obtained through the use of this material. No expressed or implied warranty is intended.
7 " continued PIPE DATA

43
While every effort has been made to ensure the accuracy of the data in these tables, this material is presented as a reference guide only. The technical information contained in these pages
should not be construed as a recommendation. Grant Prideco cannot assume responsibility for the results obtained through the use of this material. No expressed or implied warranty is intended.
T C A PIPE DATA continued 7"

44
While every effort has been made to ensure the accuracy of the data in these tables, this material is presented as a reference guide only. The technical information contained in these pages
should not be construed as a recommendation. Grant Prideco cannot assume responsibility for the results obtained through the use of this material. No expressed or implied warranty is intended.
7 " continued PIPE DATA

45
While every effort has been made to ensure the accuracy of the data in these tables, this material is presented as a reference guide only. The technical information contained in these pages
should not be construed as a recommendation. Grant Prideco cannot assume responsibility for the results obtained through the use of this material. No expressed or implied warranty is intended.
T C A PIPE DATA continued 7"

46
While every effort has been made to ensure the accuracy of the data in these tables, this material is presented as a reference guide only. The technical information contained in these pages
should not be construed as a recommendation. Grant Prideco cannot assume responsibility for the results obtained through the use of this material. No expressed or implied warranty is intended.
7 " continued PIPE DATA

47
While every effort has been made to ensure the accuracy of the data in these tables, this material is presented as a reference guide only. The technical information contained in these pages
should not be construed as a recommendation. Grant Prideco cannot assume responsibility for the results obtained through the use of this material. No expressed or implied warranty is intended.
T C A PIPE DATA continued 7"

48
While every effort has been made to ensure the accuracy of the data in these tables, this material is presented as a reference guide only. The technical information contained in these pages
should not be construed as a recommendation. Grant Prideco cannot assume responsibility for the results obtained through the use of this material. No expressed or implied warranty is intended.
7 " continued PIPE DATA

49
While every effort has been made to ensure the accuracy of the data in these tables, this material is presented as a reference guide only. The technical information contained in these pages
should not be construed as a recommendation. Grant Prideco cannot assume responsibility for the results obtained through the use of this material. No expressed or implied warranty is intended.
T C A PIPE DATA continued 7"

50
While every effort has been made to ensure the accuracy of the data in these tables, this material is presented as a reference guide only. The technical information contained in these pages
should not be construed as a recommendation. Grant Prideco cannot assume responsibility for the results obtained through the use of this material. No expressed or implied warranty is intended.
7 " continued PIPE DATA

51
While every effort has been made to ensure the accuracy of the data in these tables, this material is presented as a reference guide only. The technical information contained in these pages
should not be construed as a recommendation. Grant Prideco cannot assume responsibility for the results obtained through the use of this material. No expressed or implied warranty is intended.
T C A PIPE DATA continued 7"

52
While every effort has been made to ensure the accuracy of the data in these tables, this material is presented as a reference guide only. The technical information contained in these pages
should not be construed as a recommendation. Grant Prideco cannot assume responsibility for the results obtained through the use of this material. No expressed or implied warranty is intended.
7-5/8" PIPE DATA

53
While every effort has been made to ensure the accuracy of the data in these tables, this material is presented as a reference guide only. The technical information contained in these pages
should not be construed as a recommendation. Grant Prideco cannot assume responsibility for the results obtained through the use of this material. No expressed or implied warranty is intended.
T C A PIPE DATA continued 7-5/8"

54
While every effort has been made to ensure the accuracy of the data in these tables, this material is presented as a reference guide only. The technical information contained in these pages
should not be construed as a recommendation. Grant Prideco cannot assume responsibility for the results obtained through the use of this material. No expressed or implied warranty is intended.
7 - 5 / 8 " continued PIPE DATA

55
While every effort has been made to ensure the accuracy of the data in these tables, this material is presented as a reference guide only. The technical information contained in these pages
should not be construed as a recommendation. Grant Prideco cannot assume responsibility for the results obtained through the use of this material. No expressed or implied warranty is intended.
T C A PIPE DATA continued 7-5/8"

56
While every effort has been made to ensure the accuracy of the data in these tables, this material is presented as a reference guide only. The technical information contained in these pages
should not be construed as a recommendation. Grant Prideco cannot assume responsibility for the results obtained through the use of this material. No expressed or implied warranty is intended.
7 - 5 / 8 " continued PIPE DATA

57
While every effort has been made to ensure the accuracy of the data in these tables, this material is presented as a reference guide only. The technical information contained in these pages
should not be construed as a recommendation. Grant Prideco cannot assume responsibility for the results obtained through the use of this material. No expressed or implied warranty is intended.
T C A PIPE DATA continued 7-5/8"

58
While every effort has been made to ensure the accuracy of the data in these tables, this material is presented as a reference guide only. The technical information contained in these pages
should not be construed as a recommendation. Grant Prideco cannot assume responsibility for the results obtained through the use of this material. No expressed or implied warranty is intended.
7 - 5 / 8 " continued PIPE DATA

59
While every effort has been made to ensure the accuracy of the data in these tables, this material is presented as a reference guide only. The technical information contained in these pages
should not be construed as a recommendation. Grant Prideco cannot assume responsibility for the results obtained through the use of this material. No expressed or implied warranty is intended.
T C A PIPE DATA continued 7-5/8"

60
While every effort has been made to ensure the accuracy of the data in these tables, this material is presented as a reference guide only. The technical information contained in these pages
should not be construed as a recommendation. Grant Prideco cannot assume responsibility for the results obtained through the use of this material. No expressed or implied warranty is intended.
7 - 5 / 8 " continued PIPE DATA

61
While every effort has been made to ensure the accuracy of the data in these tables, this material is presented as a reference guide only. The technical information contained in these pages
should not be construed as a recommendation. Grant Prideco cannot assume responsibility for the results obtained through the use of this material. No expressed or implied warranty is intended.
T C A PIPE DATA continued 7-5/8"

62
While every effort has been made to ensure the accuracy of the data in these tables, this material is presented as a reference guide only. The technical information contained in these pages
should not be construed as a recommendation. Grant Prideco cannot assume responsibility for the results obtained through the use of this material. No expressed or implied warranty is intended.
7 - 5 / 8 " continued PIPE DATA

63
While every effort has been made to ensure the accuracy of the data in these tables, this material is presented as a reference guide only. The technical information contained in these pages
should not be construed as a recommendation. Grant Prideco cannot assume responsibility for the results obtained through the use of this material. No expressed or implied warranty is intended.
T C A PIPE DATA continued 7-5/8"

64
While every effort has been made to ensure the accuracy of the data in these tables, this material is presented as a reference guide only. The technical information contained in these pages
should not be construed as a recommendation. Grant Prideco cannot assume responsibility for the results obtained through the use of this material. No expressed or implied warranty is intended.
7-3/4" PIPE DATA

65
While every effort has been made to ensure the accuracy of the data in these tables, this material is presented as a reference guide only. The technical information contained in these pages
should not be construed as a recommendation. Grant Prideco cannot assume responsibility for the results obtained through the use of this material. No expressed or implied warranty is intended.
T C A PIPE DATA continued 7-3/4"

66
While every effort has been made to ensure the accuracy of the data in these tables, this material is presented as a reference guide only. The technical information contained in these pages
should not be construed as a recommendation. Grant Prideco cannot assume responsibility for the results obtained through the use of this material. No expressed or implied warranty is intended.
7 - 3 / 4 " continued PIPE DATA

67
While every effort has been made to ensure the accuracy of the data in these tables, this material is presented as a reference guide only. The technical information contained in these pages
should not be construed as a recommendation. Grant Prideco cannot assume responsibility for the results obtained through the use of this material. No expressed or implied warranty is intended.
T C A PIPE DATA 8-5/8"

68
While every effort has been made to ensure the accuracy of the data in these tables, this material is presented as a reference guide only. The technical information contained in these pages
should not be construed as a recommendation. Grant Prideco cannot assume responsibility for the results obtained through the use of this material. No expressed or implied warranty is intended.
8 - 5 / 8 " continued PIPE DATA

69
While every effort has been made to ensure the accuracy of the data in these tables, this material is presented as a reference guide only. The technical information contained in these pages
should not be construed as a recommendation. Grant Prideco cannot assume responsibility for the results obtained through the use of this material. No expressed or implied warranty is intended.
T C A PIPE DATA continued 8-5/8"

70
While every effort has been made to ensure the accuracy of the data in these tables, this material is presented as a reference guide only. The technical information contained in these pages
should not be construed as a recommendation. Grant Prideco cannot assume responsibility for the results obtained through the use of this material. No expressed or implied warranty is intended.
8 - 5 / 8 " continued PIPE DATA

71
While every effort has been made to ensure the accuracy of the data in these tables, this material is presented as a reference guide only. The technical information contained in these pages
should not be construed as a recommendation. Grant Prideco cannot assume responsibility for the results obtained through the use of this material. No expressed or implied warranty is intended.
T C A PIPE DATA continued 8-5/8"

72
While every effort has been made to ensure the accuracy of the data in these tables, this material is presented as a reference guide only. The technical information contained in these pages
should not be construed as a recommendation. Grant Prideco cannot assume responsibility for the results obtained through the use of this material. No expressed or implied warranty is intended.
8 - 5 / 8 " continued PIPE DATA

73
While every effort has been made to ensure the accuracy of the data in these tables, this material is presented as a reference guide only. The technical information contained in these pages
should not be construed as a recommendation. Grant Prideco cannot assume responsibility for the results obtained through the use of this material. No expressed or implied warranty is intended.
T C A PIPE DATA continued 8-5/8"

74
While every effort has been made to ensure the accuracy of the data in these tables, this material is presented as a reference guide only. The technical information contained in these pages
should not be construed as a recommendation. Grant Prideco cannot assume responsibility for the results obtained through the use of this material. No expressed or implied warranty is intended.
9-5/8" PIPE DATA

75
While every effort has been made to ensure the accuracy of the data in these tables, this material is presented as a reference guide only. The technical information contained in these pages
should not be construed as a recommendation. Grant Prideco cannot assume responsibility for the results obtained through the use of this material. No expressed or implied warranty is intended.
T C A PIPE DATA continued 9-5/8"

76
While every effort has been made to ensure the accuracy of the data in these tables, this material is presented as a reference guide only. The technical information contained in these pages
should not be construed as a recommendation. Grant Prideco cannot assume responsibility for the results obtained through the use of this material. No expressed or implied warranty is intended.
9 - 5 / 8 " continued PIPE DATA

77
While every effort has been made to ensure the accuracy of the data in these tables, this material is presented as a reference guide only. The technical information contained in these pages
should not be construed as a recommendation. Grant Prideco cannot assume responsibility for the results obtained through the use of this material. No expressed or implied warranty is intended.
T C A PIPE DATA continued 9-5/8"

78
While every effort has been made to ensure the accuracy of the data in these tables, this material is presented as a reference guide only. The technical information contained in these pages
should not be construed as a recommendation. Grant Prideco cannot assume responsibility for the results obtained through the use of this material. No expressed or implied warranty is intended.
9 - 5 / 8 " continued PIPE DATA

79
While every effort has been made to ensure the accuracy of the data in these tables, this material is presented as a reference guide only. The technical information contained in these pages
should not be construed as a recommendation. Grant Prideco cannot assume responsibility for the results obtained through the use of this material. No expressed or implied warranty is intended.
T C A PIPE DATA continued 9-5/8"

80
While every effort has been made to ensure the accuracy of the data in these tables, this material is presented as a reference guide only. The technical information contained in these pages
should not be construed as a recommendation. Grant Prideco cannot assume responsibility for the results obtained through the use of this material. No expressed or implied warranty is intended.
9 - 5 / 8 " continued PIPE DATA

81
While every effort has been made to ensure the accuracy of the data in these tables, this material is presented as a reference guide only. The technical information contained in these pages
should not be construed as a recommendation. Grant Prideco cannot assume responsibility for the results obtained through the use of this material. No expressed or implied warranty is intended.
T C A PIPE DATA 9-7/8"

82
While every effort has been made to ensure the accuracy of the data in these tables, this material is presented as a reference guide only. The technical information contained in these pages
should not be construed as a recommendation. Grant Prideco cannot assume responsibility for the results obtained through the use of this material. No expressed or implied warranty is intended.
9 - 7 / 8 " continued PIPE DATA

83
While every effort has been made to ensure the accuracy of the data in these tables, this material is presented as a reference guide only. The technical information contained in these pages
should not be construed as a recommendation. Grant Prideco cannot assume responsibility for the results obtained through the use of this material. No expressed or implied warranty is intended.
T C A PIPE DATA 10-3/4"

84
While every effort has been made to ensure the accuracy of the data in these tables, this material is presented as a reference guide only. The technical information contained in these pages
should not be construed as a recommendation. Grant Prideco cannot assume responsibility for the results obtained through the use of this material. No expressed or implied warranty is intended.
1 0 - 3 / 4 " continued PIPE DATA

85
While every effort has been made to ensure the accuracy of the data in these tables, this material is presented as a reference guide only. The technical information contained in these pages
should not be construed as a recommendation. Grant Prideco cannot assume responsibility for the results obtained through the use of this material. No expressed or implied warranty is intended.
T C A PIPE DATA continued 10-3/4"

86
While every effort has been made to ensure the accuracy of the data in these tables, this material is presented as a reference guide only. The technical information contained in these pages
should not be construed as a recommendation. Grant Prideco cannot assume responsibility for the results obtained through the use of this material. No expressed or implied warranty is intended.
1 0 - 3 / 4 " continued PIPE DATA

87
While every effort has been made to ensure the accuracy of the data in these tables, this material is presented as a reference guide only. The technical information contained in these pages
should not be construed as a recommendation. Grant Prideco cannot assume responsibility for the results obtained through the use of this material. No expressed or implied warranty is intended.
T C A PIPE DATA continued 10-3/4"

88
While every effort has been made to ensure the accuracy of the data in these tables, this material is presented as a reference guide only. The technical information contained in these pages
should not be construed as a recommendation. Grant Prideco cannot assume responsibility for the results obtained through the use of this material. No expressed or implied warranty is intended.
1 0 - 3 / 4 " continued PIPE DATA

89
While every effort has been made to ensure the accuracy of the data in these tables, this material is presented as a reference guide only. The technical information contained in these pages
should not be construed as a recommendation. Grant Prideco cannot assume responsibility for the results obtained through the use of this material. No expressed or implied warranty is intended.
T C A PIPE DATA continued 10-3/4"

90
While every effort has been made to ensure the accuracy of the data in these tables, this material is presented as a reference guide only. The technical information contained in these pages
should not be construed as a recommendation. Grant Prideco cannot assume responsibility for the results obtained through the use of this material. No expressed or implied warranty is intended.
1 0 - 3 / 4 " continued PIPE DATA

91
While every effort has been made to ensure the accuracy of the data in these tables, this material is presented as a reference guide only. The technical information contained in these pages
should not be construed as a recommendation. Grant Prideco cannot assume responsibility for the results obtained through the use of this material. No expressed or implied warranty is intended.
T C A PIPE DATA continued 10-3/4"

92
While every effort has been made to ensure the accuracy of the data in these tables, this material is presented as a reference guide only. The technical information contained in these pages
should not be construed as a recommendation. Grant Prideco cannot assume responsibility for the results obtained through the use of this material. No expressed or implied warranty is intended.
1 0 - 3 / 4 " continued PIPE DATA

93
While every effort has been made to ensure the accuracy of the data in these tables, this material is presented as a reference guide only. The technical information contained in these pages
should not be construed as a recommendation. Grant Prideco cannot assume responsibility for the results obtained through the use of this material. No expressed or implied warranty is intended.
T C A PIPE DATA continued 10-3/4"

94
While every effort has been made to ensure the accuracy of the data in these tables, this material is presented as a reference guide only. The technical information contained in these pages
should not be construed as a recommendation. Grant Prideco cannot assume responsibility for the results obtained through the use of this material. No expressed or implied warranty is intended.
11-3/4" PIPE DATA

95
While every effort has been made to ensure the accuracy of the data in these tables, this material is presented as a reference guide only. The technical information contained in these pages
should not be construed as a recommendation. Grant Prideco cannot assume responsibility for the results obtained through the use of this material. No expressed or implied warranty is intended.
T C A PIPE DATA continued 11-3/4"

96
While every effort has been made to ensure the accuracy of the data in these tables, this material is presented as a reference guide only. The technical information contained in these pages
should not be construed as a recommendation. Grant Prideco cannot assume responsibility for the results obtained through the use of this material. No expressed or implied warranty is intended.
1 1 - 3 / 4 " continued PIPE DATA

97
While every effort has been made to ensure the accuracy of the data in these tables, this material is presented as a reference guide only. The technical information contained in these pages
should not be construed as a recommendation. Grant Prideco cannot assume responsibility for the results obtained through the use of this material. No expressed or implied warranty is intended.
T C A PIPE DATA continued 11-3/4"

98
While every effort has been made to ensure the accuracy of the data in these tables, this material is presented as a reference guide only. The technical information contained in these pages
should not be construed as a recommendation. Grant Prideco cannot assume responsibility for the results obtained through the use of this material. No expressed or implied warranty is intended.
1 1 - 3 / 4 " continued PIPE DATA

99
While every effort has been made to ensure the accuracy of the data in these tables, this material is presented as a reference guide only. The technical information contained in these pages
should not be construed as a recommendation. Grant Prideco cannot assume responsibility for the results obtained through the use of this material. No expressed or implied warranty is intended.
T C A PIPE DATA 11-7/8"

100
While every effort has been made to ensure the accuracy of the data in these tables, this material is presented as a reference guide only. The technical information contained in these pages
should not be construed as a recommendation. Grant Prideco cannot assume responsibility for the results obtained through the use of this material. No expressed or implied warranty is intended.
13-3/8" PIPE DATA

101
While every effort has been made to ensure the accuracy of the data in these tables, this material is presented as a reference guide only. The technical information contained in these pages
should not be construed as a recommendation. Grant Prideco cannot assume responsibility for the results obtained through the use of this material. No expressed or implied warranty is intended.
T C A PIPE DATA continued 13-3/8"

102
While every effort has been made to ensure the accuracy of the data in these tables, this material is presented as a reference guide only. The technical information contained in these pages
should not be construed as a recommendation. Grant Prideco cannot assume responsibility for the results obtained through the use of this material. No expressed or implied warranty is intended.
1 3 - 3 / 8 " continued PIPE DATA

103
While every effort has been made to ensure the accuracy of the data in these tables, this material is presented as a reference guide only. The technical information contained in these pages
should not be construed as a recommendation. Grant Prideco cannot assume responsibility for the results obtained through the use of this material. No expressed or implied warranty is intended.
T C A PIPE DATA continued 13-3/8"

104
While every effort has been made to ensure the accuracy of the data in these tables, this material is presented as a reference guide only. The technical information contained in these pages
should not be construed as a recommendation. Grant Prideco cannot assume responsibility for the results obtained through the use of this material. No expressed or implied warranty is intended.
1 3 - 3 / 8 " continued PIPE DATA

105
While every effort has been made to ensure the accuracy of the data in these tables, this material is presented as a reference guide only. The technical information contained in these pages
should not be construed as a recommendation. Grant Prideco cannot assume responsibility for the results obtained through the use of this material. No expressed or implied warranty is intended.
T C A PIPE DATA continued 13-3/8"

106
While every effort has been made to ensure the accuracy of the data in these tables, this material is presented as a reference guide only. The technical information contained in these pages
should not be construed as a recommendation. Grant Prideco cannot assume responsibility for the results obtained through the use of this material. No expressed or implied warranty is intended.
13-1/2" PIPE DATA

107
While every effort has been made to ensure the accuracy of the data in these tables, this material is presented as a reference guide only. The technical information contained in these pages
should not be construed as a recommendation. Grant Prideco cannot assume responsibility for the results obtained through the use of this material. No expressed or implied warranty is intended.
T C A PIPE DATA 13-5/8"

108
While every effort has been made to ensure the accuracy of the data in these tables, this material is presented as a reference guide only. The technical information contained in these pages
should not be construed as a recommendation. Grant Prideco cannot assume responsibility for the results obtained through the use of this material. No expressed or implied warranty is intended.
16" PIPE DATA

109
While every effort has been made to ensure the accuracy of the data in these tables, this material is presented as a reference guide only. The technical information contained in these pages
should not be construed as a recommendation. Grant Prideco cannot assume responsibility for the results obtained through the use of this material. No expressed or implied warranty is intended.
T C A PIPE DATA continued 16"

110
While every effort has been made to ensure the accuracy of the data in these tables, this material is presented as a reference guide only. The technical information contained in these pages
should not be construed as a recommendation. Grant Prideco cannot assume responsibility for the results obtained through the use of this material. No expressed or implied warranty is intended.
1 6 " continued PIPE DATA

111
While every effort has been made to ensure the accuracy of the data in these tables, this material is presented as a reference guide only. The technical information contained in these pages
should not be construed as a recommendation. Grant Prideco cannot assume responsibility for the results obtained through the use of this material. No expressed or implied warranty is intended.
T C A PIPE DATA continued 16"

112
While every effort has been made to ensure the accuracy of the data in these tables, this material is presented as a reference guide only. The technical information contained in these pages
should not be construed as a recommendation. Grant Prideco cannot assume responsibility for the results obtained through the use of this material. No expressed or implied warranty is intended.
16-1/8" PIPE DATA

113
While every effort has been made to ensure the accuracy of the data in these tables, this material is presented as a reference guide only. The technical information contained in these pages
should not be construed as a recommendation. Grant Prideco cannot assume responsibility for the results obtained through the use of this material. No expressed or implied warranty is intended.
T C A PIPE DATA continued 16-1/8"

114
While every effort has been made to ensure the accuracy of the data in these tables, this material is presented as a reference guide only. The technical information contained in these pages
should not be construed as a recommendation. Grant Prideco cannot assume responsibility for the results obtained through the use of this material. No expressed or implied warranty is intended.
09/02